It is always recommended to anchor the unit to the ground. Drill through the four holes in the base of the unit using 6mm dia masonry drill to a depth of 70mm. Screw in the anchor fixings. (These have a self cutting thread). If not anchoring the unit, fit the self seal plugs BEFORE BUILDING to seal the fixing holes from underneath. Please note product must be bolted down to comply with LPS1175. TOOLS REQUIRED Power driver POSI-DRIV screwdriver, 6mm dia. masonry drill and a 13mm socket or spanner. MOTORCYCLE GARAGE BASE INSTRUCTIONS Flat and firm base. Recommended: concrete, tarmac or paving flags. Min. distance from walls/ shrubbery: 1000mm. Min. base size (WxDxH) 3215mm x 1730mm x 50mm. LEVELING THE UNIT Correctly level the constructed unit using the shims (ZCOMPPLAS) provided prior to fixing the unit to the ground. Slide the packing pieces under the corners of the unit base as required until an equal gap has been achieved around the door allowing for its smooth operation and alignment. For maintenance instructions of this product visit www.asgardsss.co.uk Warning: some panels may weigh over 20Kg. Beware of manual handling 13mm Spanner 18V x2 SEALANT LH R. SIDE PANEL 32874 x1 LH EXT. PNL F. BASE PNL 32940 x1 R. BASE PNL 32871 x1 EXT BASE 42185 x1 LH DOOR 32943 x1 RH DOOR 32944 x1 FRONT FASCIA 32948 x1 ZSCREW32 x12 ZSILCO1 x2 ZSCREW04 x4 ZSCREW100 x277 ZSCREW340 x24 32670 x22 ZCOMPPLZS02 x12 ZCOMPPLAS22-23-24 x18 6x 2mm, 6x 3mm, 6x 5mm BASE COVER CHANNEL 37364 x2 SIDE COVER CHANNEL 32916 x4 ROOF COVER CHANNEL 32918 x4 RH F. SIDE PNL 32942 x1 RH EXT. PNL 42516 x1 LH BACK PANEL 32867 x1 RH BACK PANEL 32876 x1 TOP SHROUD 32945 x2 EXT. 1/2 SHROUD 42187 x1 RH R. SIDE PNL 32875 x1 F. TOP PANEL 32986 x1 R. TOP PANEL 32987 x1 EXT. 1/2 TOP PNL 42186 x1 LH F. SIDE PANEL 32941 x1 Warning: Please keep this key card safe! Refer to if replacement key is required. 00001 YOUR UNIQUE KEY CODE 42515 x1 ROOF JOINT STRIP 40446 x4 6mm Dia. Posi-Driv Screwdriver

Upload: asgard-secure-steel-storage

Post on 24-Jul-2016

228 views

Category:

Documents


3 download

DESCRIPTION

For more information please visit www.asgardsss.co.uk

TRANSCRIPT

Page 1: Asgard Motorcycle Storage Instructions

It is always recommended to anchor the unit to the ground. Drill through the four holes in the base of the unit using 6mm dia masonry drill to a depth of 70mm. Screw in the anchor fixings. (These have a self cutting thread). If not anchoring the unit, fit the self seal plugs BEFORE BUILDING to seal the fixing holes from underneath. Please note product must be bolted down to comply with LPS1175.

TOOLS REQUIREDPower driver POSI-DRIV screwdriver, 6mm dia. masonry drill and a13mm socket or spanner.

MOTORCYCLE GARAGEBASE INSTRUCTIONSFlat and firm base. Recommended: concrete, tarmac or paving flags. Min. distance from walls/ shrubbery: 1000mm.Min. base size (WxDxH) 3215mm x 1730mm x 50mm.

LEVELING THE UNITCorrectly level the constructed unit using the shims (ZCOMPPLAS) provided prior to fixing the unit to the ground. Slide the packing pieces under the corners of the unit base as required until an equal gap has been achieved around the door allowing for its smooth operation and alignment.

For maintenance instructions of this product visit www.asgardsss.co.uk

Warning: some panels may weigh over 20Kg. Beware of manual handling

13mm Spanner

18V

x2

SEAL

ANT

LH R. SIDE PANEL

32874 x1

LH EXT. PNL

F. BASE PNL

32940 x1

R. BASE PNL

32871 x1

EXT

BASE

42185 x1

LH

DO

OR

3294

3 x1

RH

DO

OR

3294

4 x1

FRONT FASCIA32948 x1

ZSC

REW

32 x

12

ZSIL

CO

1 x

2

ZSC

REW

04 x

4

ZSC

REW

100

x27

7

ZSC

REW

340

x24

3267

0 x

22

ZCO

MPP

LZS0

2 x

12

ZCO

MPP

LAS2

2-23

-24

x18

6x 2

mm

, 6x

3mm

, 6x

5mm

BASE

CO

VER

CH

ANN

EL 3

7364

x2

SID

E C

OVE

R C

HAN

NEL

329

16 x

4

RO

OF

CO

VER

CH

ANN

EL

329

18 x

4

RH F. SIDE PNL

32942 x1

RH EXT. PNL

42516 x1

LH

BAC

K PA

NEL

3286

7 x1

RH

BAC

K PA

NEL

3287

6 x1

TOP SHROUD

32945 x2

EXT. 1/2 SHROUD

42187 x1

RH R. SIDE PNL

32875 x1

F. TOP PANEL

32986 x1

R. TOP PANEL

32987 x1

EXT. 1/2

TOP PNL

42186 x1

LH F. SIDE PANEL

32941 x1

Warning: Please keepthis key card safe! Referto if replacement key is required.

00001

YOUR UNIQUEKEY CODE

42515 x1

ROOF JOINT

STRIP 40446 x4

6mm Dia.

Posi-DrivScrewdriver

Page 2: Asgard Motorcycle Storage Instructions

RH

BAC

K PA

NEL

3287

6

RH

R. S

IDE

PAN

EL32

875

REAR BASE PANEL

32871

x15

1

3

5 6

4

2

x19 x22

x10

PLEASE NOTE ALL SCREWS ARE FIXED FROM THE INSIDE

LH R

. SID

E PA

NEL

3287

4

x16 x13

R. T

OP

PAN

EL32

987

EXT. BASE PANEL

42185 x1

LH B

ACK

PAN

EL32

867

x15

x7

x3

x16

x3

x15

x7

x13

x4

x4x4

x4

Page 3: Asgard Motorcycle Storage Instructions

7 8

9 10

11 12

x40 x20

x13 x44

x6 x30

EXT. 1/2 TOP PANEL

42186

LH E

XT. P

ANEL

4251

5

RH

. EXT

. PAN

EL42

516

F. TOP PANEL

32986

RH F. SIDE PNL

32942

LH F. SIDE PANEL

32941

FRONT FASCIA

32948

x15

x15

x3

x3

x7

x7

x5

x5

x13x7

x7

x15

x15

x4

x4

x4 x7

x7

x4

x3

x3

F. BASE PNL

32940

Page 4: Asgard Motorcycle Storage Instructions

x3

x3x4

x4x3

x3

x3

x2

x2

x3

x3

x3

13 14

15 16

17 18

www.asgardsss.co.uk

x12

054367/15.01.16/KW/REV1

REMOVE SCREWS WHICH ALIGNWITH THE COVER CHANNELS. ALIGN AND PLACE SCREWS BACK!

BASE

CO

VER

CH

ANN

EL 3

7364

1ST TOP SHROUD

32945

SHROUDS 32945 & 32996

2ND TOP SHROUD

32945

x4

EXT. TOP

SHROUD

42187

LH D

OO

R32

943

RH

DO

OR

32

944

x24

x22

x8

3267

0

SID

E C

OVE

R C

HAN

NEL

329

16

RO

OF

CO

VER

CH

ANN

EL 3

2918

ROOF JOINT STRIP 40446

APPLY TO ALL

ROOF JOINT STRIP 40446

ROOF JOINT STRIP END40446

SHROUDS

ROOF STRIP