asme a17.1, asme a17.1, part v, section 5.3 section 5.3 v, … · 2020. 8. 7. · the ease of use...
TRANSCRIPT
Elevating Solutions
COUNTRY HOME Elevator & Stair Lift
P r i v a t e R e s i d e n c e E l e v a t o r D E S I G N G U I D E
ASME A17 .1 , PART V, S ECT ION 5 .3
r
Elevating Solutions
COUNTRY HOME Elevator & Stair Lift
Private Residence Elevator DESIGN GUIDE
ASME A17.1, PART V, SECTION 5.3
r
CONTRACTOR NOTES:
• Furnish appropriate wall supports for T-Rail (see page 7)
• Consult Country Home Elevator for spans greater than 10’ between floor joists
• Maintain below 1/8” tolerances throughout hoistway
• Rail backing wall must be a load bearing wall
• Pit floor must be a minimum of 6” below the finished floor of the lowest landing
• Construction of pit floor must withstand an impact load of 2400#
• 8’0” minimum hoistway overhead above the finished floor at the top landing is required for 7’0” car with remote controller.
• 9’0” minimum hoistway overhead above the finished floor at the top landing is required for 7’0” car with controller located in the hoistway
• Provide an access hatch for servicing the controller/drive unit (see page 9)
• Hoistway doors provided by others. Minimum 3’0” x 6’8” solid core doors are recommended
• Hoistway must be free of any obstructions unrelated to the elevator operation (i.e. sprinklers, pipes, ducts, etc,)
• The structure of the hoistway must allow for installation of a chain hoist to transfer materials to the upper landings during elevator installation
2
TABLE OF CONTENTS
Contractor Notes 2
Equipment for Country Home Elevator 3
Typical Hoistway Configurations 4-6
Typical Hoistway Construction 7-8
Typical Machine Room Layouts 9-10
System Overview 11
•FurnishappropriatewallsupportsforT-Rail(seepage10)
•ConsultCountryHomeElevatorforspansgreaterthan10’betweenfloorjoists
•Maintainbelow1/8”tolerancesthroughouthoistway
•Railbackingwallmustbealoadbearingwall
•Pitfloormustbeaminimumof6”belowthefinishedfloorofthelowestlanding
•Constructionofpitfloormustwithstandanimpactloadof2400#
•8’0”minimumhoistwayoverheadabovethefinishedflooratthetoplandingis requiredfor7’0”carwithremotecontroller.
•9’0”minimumhoistwayoverheadabovethefinishedflooratthetoplandingis requiredfor7’0”carwithcontrollerlocatedinthehoistway
•Provideanaccesshatchforservicingthecontroller/driveunit(seepage12)
•Hoistwaydoorsprovidedbyothers.Minimum3’0”x6’8”solidcoredoorsare recommended
•Hoistwaymustbefreeofanyobstructionsunrelatedtotheelevatoroperation (i.e.sprinklers,pipes,ducts,etc.)
•Thestructureofthehoistwaymustallowforinstallationofachainhoisttotransfer materialstotheupperlandingsduringelevatorinstallation
14Elevating Solutions
Private Residential Elevator Specifications
COUNTRY HOME Elevator & Stair Lift
CABS • GATES • CALL STATIONS • EQUIPMENT SPECIFICATIONS • HOISTWAY CONFIGURATIONS & CONTSTRUCTION • MACHINE ROOM LAYOUTS
3
Table of Contents
Cab Panel Styles 2Gates & Door Styles 3Call Stations 4Equipment Specifications 5Typical Hoistway Configurations 6Typical Hoistway Construction 7Safety Notice 8Flush Door Details 9-10Typical Machine Room Layouts 11-12
CONTRACTOR NOTES:
• Furnish appropriate wall supports for T-Rail (see page 7)
• Consult Country Home Elevator for spans greater than 10’ between floor joists
• Maintain below 1/8” tolerances throughout hoistway
• Rail backing wall must be a load bearing wall
• Pit floor must be a minimum of 6” below the finished floor of the lowest landing
• Construction of pit floor must withstand an impact load of 2400#
• 8’0” minimum hoistway overhead above the finished floor at the top landing is required for 7’0” car with remote controller.
• 9’0” minimum hoistway overhead above the finished floor at the top landing is required for 7’0” car with controller located in the hoistway
• Provide an access hatch for servicing the controller/drive unit (see page 9)
• Hoistway doors provided by others. Minimum 3’0” x 6’8” solid core doors are recommended
• Hoistway must be free of any obstructions unrelated to the elevator operation (i.e. sprinklers, pipes, ducts, etc,)
• The structure of the hoistway must allow for installation of a chain hoist to transfer materials to the upper landings during elevator installation
2
TABLE OF CONTENTS
Contractor Notes 2
Equipment for Country Home Elevator 3
Typical Hoistway Configurations 4-6
Typical Hoistway Construction 7-8
Typical Machine Room Layouts 9-10
System Overview 11
•FurnishappropriatewallsupportsforT-Rail(seepage10)
•ConsultCountryHomeElevatorforspansgreaterthan10’betweenfloorjoists
•Maintainbelow1/8”tolerancesthroughouthoistway
•Railbackingwallmustbealoadbearingwall
•Pitfloormustbeaminimumof6”belowthefinishedfloorofthelowestlanding
•Constructionofpitfloormustwithstandanimpactloadof2400#
•8’0”minimumhoistwayoverheadabovethefinishedflooratthetoplandingis requiredfor7’0”carwithremotecontroller.
•9’0”minimumhoistwayoverheadabovethefinishedflooratthetoplandingis requiredfor7’0”carwithcontrollerlocatedinthehoistway
•Provideanaccesshatchforservicingthecontroller/driveunit(seepage12)
•Hoistwaydoorsprovidedbyothers.Minimum3’0”x6’8”solidcoredoorsare recommended
•Hoistwaymustbefreeofanyobstructionsunrelatedtotheelevatoroperation (i.e.sprinklers,pipes,ducts,etc.)
•Thestructureofthehoistwaymustallowforinstallationofachainhoisttotransfer materialstotheupperlandingsduringelevatorinstallation
14Elevating Solutions
Private Residential Elevator Specifications
COUNTRY HOME Elevator & Stair Lift
CABS • GATES • CALL STATIONS • EQUIPMENT SPECIFICATIONS • HOISTWAY CONFIGURATIONS & CONTSTRUCTION • MACHINE ROOM LAYOUTS
3
Table of Contents
Cab Panel Styles 2Gates & Door Styles 3Call Stations 4Equipment Specifications 5Typical Hoistway Configurations 6Typical Hoistway Construction 7Safety Notice 8Flush Door Details 9-10Typical Machine Room Layouts 11-12
Standard Features• Up to six stops• Multiple drive systems available:
- In-Line Geared (MRL - Machine Room Less) - Roped Hydraulic system
• Cab sizes from 12 to 18 square feet (available cab size may vary depending on local codes)
• 7’ interior height with 8’ overhead is standard (8’ interior height with 9’ overhead is optional)
• Automatic cab lighting • 1000 lb. capacity• Car Operating Panel with push-button
operation and LED floor position indicator• Hall call stations with call button and
car arrival indicator• Three year limited parts warranty • Two energy saving recessed LED
overhead lights with black trim rings• Recessed phone box in brushed
stainless steel
Optional Enhancements:• One touch automatic operation of
hoistway doors and car gate• Four recessed LED overhead lights with
choice of finish• Integrated telephone in car
operating panel
Safety Features• In-car alarm button, emergency stop
switch and telephone• Battery backup - if the power’s out, the
lights and alarm are on• Uninterrupted power - lower the car and
open the gate even in a blackout• Slack rope/chain safety device• Motor control supply (located in controller) • Car light supply (located in control)• Upper and lower final limits • Car top stop switch• Electromechanical hoistway door inter
locks (keeps the hoistway door secure)• Manual lowering device
Match the style and quality of any home with standard options Birch, Oak, Maple or additional options like Alder, Cherry, Walnut, Hickory, Mahogany or White Oak.
Panel Woods
3
Additional OptionsStandard Options
Shaker Panel
Raised Panel
Flat Panel
Inset Panel
Cab Panel StylesWith USA made quality, beautiful crafts-manship, expert engineering, and afford-ability; Symmetry Elevating Solutions offers flat panel hardwood walls, flat ceiling, matching wood handrail with clean lines, timeless style and more.
2
Cab P
ane
l Sty
les
The basic cab gate is the manual
accordion-fold type, which is made
of laminate or hardwood and folds
out like an accordion. An upgrade
is available with an automatic
opening and closing device which
allows the door to close, even if
someone accidently forgets to close
it on their way out. That avoids the
elevator being stuck on another level
because the safety device will not
allow it to move without the gate
being closed.
The Vintage Scissor Gate is a metal
gate with an antique look. It allows
for a more open feel than the
accordian-style, but cannot be equipped
with an automatic opening and closing
device because of safety concerns.
Sliding doors come in two styles,
our exclusive Symmetry Safety Three
Panel Door and commercial style
Stainless Steel Two Speed Doors.
Sliding Doors
Symmetry SafetyThree Panel Door
Stainless SteelTwo Speed Doors
Accordion Fold Scissor Fold
Laminate Gate Vintage Scissor Gate
Elevator Gate & Door Styles Accordion Style Gate
Scissors Style Gate
Sliding Style Doors
Power LandingDoor Operator
• A variety of laminate and hardwood gates are available.
• Power Landing Door Operators are available to enhance the ease of use with accordion gates.
• Two styles of stainless steel side sliding doors are available.
Gate Options
Power Landing Door Operators are
available to enhance the ease of use
with accordion gates.
Gate
s &
Doo
r St
yles
Standard Features• Up to six stops• Multiple drive systems available:
- In-Line Geared (MRL - Machine Room Less) - Roped Hydraulic system
• Cab sizes from 12 to 18 square feet (available cab size may vary depending on local codes)
• 7’ interior height with 8’ overhead is standard (8’ interior height with 9’ overhead is optional)
• Automatic cab lighting • 1000 lb. capacity• Car Operating Panel with push-button
operation and LED floor position indicator• Hall call stations with call button and
car arrival indicator• Three year limited parts warranty • Two energy saving recessed LED
overhead lights with black trim rings• Recessed phone box in brushed
stainless steel
Optional Enhancements:• One touch automatic operation of
hoistway doors and car gate• Four recessed LED overhead lights with
choice of finish• Integrated telephone in car
operating panel
Safety Features• In-car alarm button, emergency stop
switch and telephone• Battery backup - if the power’s out, the
lights and alarm are on• Uninterrupted power - lower the car and
open the gate even in a blackout• Slack rope/chain safety device• Motor control supply (located in controller) • Car light supply (located in control)• Upper and lower final limits • Car top stop switch• Electromechanical hoistway door inter
locks (keeps the hoistway door secure)• Manual lowering device
Match the style and quality of any home with standard options Birch, Oak, Maple or additional options like Alder, Cherry, Walnut, Hickory, Mahogany or White Oak.
Panel Woods
3
Additional OptionsStandard Options
Shaker Panel
Raised Panel
Flat Panel
Inset Panel
Cab Panel StylesWith USA made quality, beautiful crafts-manship, expert engineering, and afford-ability; Symmetry Elevating Solutions offers flat panel hardwood walls, flat ceiling, matching wood handrail with clean lines, timeless style and more.
2
Cab P
ane
l Sty
les
The basic cab gate is the manual
accordion-fold type, which is made
of laminate or hardwood and folds
out like an accordion. An upgrade
is available with an automatic
opening and closing device which
allows the door to close, even if
someone accidently forgets to close
it on their way out. That avoids the
elevator being stuck on another level
because the safety device will not
allow it to move without the gate
being closed.
The Vintage Scissor Gate is a metal
gate with an antique look. It allows
for a more open feel than the
accordian-style, but cannot be equipped
with an automatic opening and closing
device because of safety concerns.
Sliding doors come in two styles,
our exclusive Symmetry Safety Three
Panel Door and commercial style
Stainless Steel Two Speed Doors.
Sliding Doors
Symmetry SafetyThree Panel Door
Stainless SteelTwo Speed Doors
Accordion Fold Scissor Fold
Laminate Gate Vintage Scissor Gate
Elevator Gate & Door Styles Accordion Style Gate
Scissors Style Gate
Sliding Style Doors
Power LandingDoor Operator
• A variety of laminate and hardwood gates are available.
• Power Landing Door Operators are available to enhance the ease of use with accordion gates.
• Two styles of stainless steel side sliding doors are available.
Gate Options
Power Landing Door Operators are
available to enhance the ease of use
with accordion gates.
Gate
s &
Doo
r St
yles
Elevator Fixture Options All the following are available in Polished or Brushed Stainless Steel, Polished or Brushed Brass, Vintage Bronze and Black:
• Car operation panels • Phone boxes• Handrails• Recessed lights • Hall calls
R E C E S S E D C A B L I G H T S
Polished Brass Black Enamel Vintage Bronze
Antique BrassBlack Enamel
Brushed Brass Polished Brass
Vintage BronzeBrushed Stainless (Standard)
4 5
Equi
pm
ent
Spec
ifica
tions
Call Station Styles & Finishes
Polished Stainless
Call
Statio
ns
Elevator Fixture Options All the following are available in Polished or Brushed Stainless Steel, Polished or Brushed Brass, Vintage Bronze and Black:
• Car operation panels • Phone boxes• Handrails• Recessed lights • Hall calls
R E C E S S E D C A B L I G H T S
Polished Brass Black Enamel Vintage Bronze
Antique BrassBlack Enamel
Brushed Brass Polished Brass
Vintage BronzeBrushed Stainless (Standard)
4 5
Equi
pm
ent
Spec
ifica
tions
Call Station Styles & Finishes
Polished Stainless
Call
Statio
ns
76
Typic
al H
oist
way
Cons
truc
tion
Typic
al H
oist
way
Confi
gur
atio
ns
*36” available with additional Deep gate pocket. Only available from Symmetry Systems.
*36” available with additional Deep gate pocket. Only available from Symmetry Systems.
*36” available with additional Deep gate pocket. Only available from Symmetry Systems.
76
Typic
al H
oist
way
Cons
truc
tion
Typic
al H
oist
way
Confi
gur
atio
ns
*36” available with additional Deep gate pocket. Only available from Symmetry Systems.
*36” available with additional Deep gate pocket. Only available from Symmetry Systems.
*36” available with additional Deep gate pocket. Only available from Symmetry Systems.
Required to meet the 2016 ASME 5.3 code where adopted.
98
Flus
h D
oor
Det
ails
Safe
ty N
otic
e
Required to meet the 2016 ASME 5.3 code where adopted.
98
Flus
h D
oor
Det
ails
Safe
ty N
otic
e
1191110
Flus
h D
oor
Det
ails
Typic
al M
ach
ine
Roo
m L
ayo
uts
1191110
Flus
h D
oor
Det
ails
Typic
al M
ach
ine
Roo
m L
ayo
uts
12
Typic
al M
ach
ine
Roo
m L
ayo
uts
12
Typic
al M
ach
ine
Roo
m L
ayo
uts
A Country Home Elevator Opens New Doors To Freedom
COUNTRY HOME Elevator & Stair Lift
CORPORATE OFFICE1549 E. 559th Road Brighton, MO 65617 800.898.5090
OKLAHOMA OFFICE7136 S Yale Ave Suite 300Tulsa, OK 74136 800.482.1931
ARKANSAS OFFICE609 SW 8th St. Suite 600Bentonville, AR 72712 800.313.5640
KANSAS CITY OFFICE5251 W 116th Place Suite 200Leawood, KS 66221 888.869.8883
ST. LOUIS OFFICE111 West Port Plaza 6th FloorSt. Louis, MO 63146 800.469.5073
[email protected] CountryHomeElevator.com
A Country Home Elevator Opens New Doors To Freedom
COUNTRY HOME Elevator & Stair Lift
CORPORATE OFFICE1549 E. 559th Road Brighton, MO 65617 800.898.5090
OKLAHOMA OFFICE7136 S Yale Ave Suite 300Tulsa, OK 74136 800.482.1931
ARKANSAS OFFICE609 SW 8th St. Suite 600Bentonville, AR 72712 800.313.5640
KANSAS CITY OFFICE5251 W 116th Place Suite 200Leawood, KS 66221 888.869.8883
ST. LOUIS OFFICE111 West Port Plaza 6th FloorSt. Louis, MO 63146 800.469.5073
[email protected] CountryHomeElevator.com