assignment 7 solutions
DESCRIPTION
Assignment 7 solutions. Karnaugh Map for "b". Truth Table. BA. DC. Another Example: 7 segment displays. BA. BA. DC. DC. Another Example: 7 segment displays. BA. BA. DC. DC. C'+A'B'+AB. Another Example: 7 segment displays. Karnaugh Map for "f". Truth Table. BA. DC. - PowerPoint PPT PresentationTRANSCRIPT
Assignment 7 solutions
Truth TableKarnaugh Map for "b"
00 01 11 10
00 1 1 1 1
01 1 0 1 0
11 x x x x
10 1 1 x x
DCBA
Another Example: 7 segment displays
00 01 11 10
00 1 1 1 1
01 1 0 1 0
11 x x x x
10 1 1 x x
DCBA 00 01 11 10
00 1 1 1 1
01 1 0 1 0
11 1 0 1 0
10 1 1 1 1
DCBA
Another Example: 7 segment displays
00 01 11 10
00 1 1 1 1
01 1 0 1 0
11 1 0 1 0
10 1 1 1 1
DCBA 00 01 11 10
00 1 1 1 1
01 1 0 1 0
11 1 0 1 0
10 1 1 1 1
DCBA
C'+A'B'+AB
Another Example: 7 segment displays
Truth TableKarnaugh Map for "f"
00 01 11 10
00 1 0 0 0
01 1 1 0 1
11 x x x x
10 1 1 x x
DCBA
Another Example: 7 segment displays
00 01 11 10
00 1 0 0 0
01 1 1 0 1
11 x x x x
10 1 1 x x
DCBA 00 01 11 10
00 1 0 0 0
01 1 1 0 1
11 1 1 1 1
10 1 1 1 1
DCBA
00 01 11 10
00 1 0 0 0
01 1 1 0 1
11 1 1 1 1
10 1 1 1 1
DCBA 00 01 11 10
00 1 0 0 0
01 1 1 0 1
11 1 1 1 1
10 1 1 1 1
DCBA
00 01 11 10
00 1 0 0 0
01 1 1 0 1
11 1 1 1 1
10 1 1 1 1
DCBA 00 01 11 10
00 1 0 0 0
01 1 1 0 1
11 1 1 1 1
10 1 1 1 1
DCBA
D B'A'
B'C A'C
B'C+A'C+B'A'+D
A water purification plant uses one tank for chemical sterilization and a second, larger tank for settling and aeration. Each tank is equipped with two sensors that measure the height of water in each tank and the flow rate of water into each tank. When the height or the flow rate of water is too high, the sensors produce a logic high output. Design a logic circuit that sounds an alarm whenever the height of water in both tanks is too high and either of the flow rates is too high, or whenever both flow rates are too high and the height of water in either tank is too high
Af Ah Bf Bh O
0 0 0 0 0
0 0 0 1 0
0 0 1 0 0
0 0 1 1 0
0 1 0 0 0
0 1 0 1 0
0 1 1 0 0
0 1 1 1 1
1 0 0 0 0
1 0 0 1 0
1 0 1 0 0
1 0 1 1 1
1 1 0 0 0
1 1 0 1 1
1 1 1 0 1
1 1 1 1 1
00 01 11 10
00 0 0 0 0
01 0 0 1 0
11 0 1 1 1
10 0 0 1 0
AfAh
BfBh
AfAhBh+ AfAhBf+ BfBhAf+ BfBhAh
AfAh(Bf+Bh) + BfBh(Af+Ah)
A water purification plant uses one tank for chemical sterilization and a second, larger tank for settling and aeration. Each tank is equipped with two sensors that measure the height of water in each tank and the flow rate of water into each tank. When the height or the flow rate of water is too high, the sensors produce a logic high output. Design a logic circuit that sounds an alarm whenever the height of water in both tanks is too high and either of the flow rates is too high, or whenever both flow rates are too high and the height of water in either tank is too high
AfAh(Bf+Bh) + BfBh(Af+Ah)
AfAh(Bf+Bh)
BfBh(Af+Ah)