at-1500 test report · test(s) marked with ‘#’ is/are not covered under the scope of...

154
TEST REPORT Test Report # 18H009740 Date of Report Issue: March 26, 2019 Date of Sample Received: December 14, 2018 Pages: Page 1 of 154 QIMA Testing (HK) Limited 3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSIASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. CS-HK-RE005-POLY Ver.12 In December 2018, ANSECO became QIMA. AT-1500 CLIENT INFORMATION: Company: Polyconcept GBS Recipient: Patrick Lam Recipient Email: [email protected] SAMPLE INFORMATION: Description: Refer to page 2 to 10 Assortment: Purchase Order Number: Article No.: Refer to Page 2 to 10 Toy Co./Agency: Vendor Name: 10583 Country of Origin: China Country of Distribution: United States, Canada Labeled Age Grade: Quantity Submitted: Refer to Page 2 to 10 Requested Age Grade: Testing Period: 12/18/2018 – 01/15/2019 02/19/2019 – 03/08/2019 03/18/2019 – 03/25/2019 Tested Age Grade: OVERALL RESULT: PASS Refer to page 11 for test result summary and appropriate notes. QIMA Testing (HK) Limited Loska Yeung Lok Ka Assistant Manager, Chemical Laboratory

Upload: others

Post on 14-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

TEST REPORT   Test Report #  18H‐009740  Date of Report Issue:  March 26, 2019 

Date of Sample Received:  December 14, 2018  Pages:   Page 1 of 154 

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

AT-1500

CLIENT INFORMATION:     

Company:    Polyconcept GBS 

Recipient:   Patrick Lam 

Recipient Email:  [email protected]

 

SAMPLE INFORMATION:   

Description:  Refer to page 2 to 10 

Assortment:  ‐  Purchase Order Number:  ‐ 

Article No.:  Refer to Page 2 to 10 Toy Co./Agency: ‐ 

Vendor Name:  10583  Country of Origin:  China 

Country of Distribution:  United States, Canada  Labeled Age Grade:  ‐ 

Quantity Submitted:  Refer to Page 2 to 10  Requested Age Grade:  ‐ 

Testing Period:  12/18/2018 – 01/15/2019 02/19/2019 – 03/08/2019 03/18/2019 – 03/25/2019 

Tested Age Grade:  ‐ 

     

OVERALL RESULT: 

  PASS   

Refer to page 11 for test result summary and appropriate notes.    

QIMA Testing (HK) Limited 

 

 

Loska Yeung Lok Ka 

Assistant Manager, Chemical Laboratory 

Page 2: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 2 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 ARTICLE/PO NO./ QUANTITY SUBMITTED DETAILED:   

Style description  Article No.  PO No.  Qty. 

Mega Dble‐Wall Plastic Tumbler  1622‐84 WH  1786608  6 pcs 

Hot & Cold Flip Skinny Tumbler 1623‐49 BK  1589175  6 pcs 

1623‐49 BL  1778928  6 pcs 

Hot & Cold Flip Vortex Tumbler 

1623‐57 BK  1766210  6 pcs 

1623‐57 BL  1789058  6 pcs 

1623‐57 CL  1759185  6 pcs 

1623‐57 GR  1770533  6 pcs 

1623‐57 OR  1786610  6 pcs 

1623‐57 RD  1766638  6 pcs 

Mega Vortex Tumbler 

1623‐65 BK  1786653  6 pcs 

1623‐65 BL  1790226  6 pcs 

1623‐65 CL  1794335  6 pcs 

1623‐65 GR  1779256  4 pcs 

1623‐65 OR  1783951  6 pcs 

1623‐65 RD  1747748  5 pcs 

Fruiton BPA Free Inf Tritan Btle  

1623‐82 BL  1719449  6 pcs 

1623‐82 GR  1732077  6 pcs 

1623‐82 GY  1762712  6 pcs 

1623‐82 RD  1743340  6 pcs 

1623‐82 TQ  1766802  6 pcs 

Game Day Cup w/lid 

1623‐91 BK  1766921  6 pcs 

1623‐91 BL  1766212  6 pcs 

1623‐91 RD  1770788  6 pcs 

Ice Cool Tumbler  

1623‐94 BL  1781510  6 pcs 

1623‐94 TQ  1776704  6 pcs 

1623‐94 WH  1779673  4 pcs 

Vintage Mason Jar  1624‐15 SGL  1770534  6 pcs 

   

Page 3: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 3 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 ARTICLE/PO NO./ QUANTITY SUBMITTED DETAILED:   

Style description  Article No.  PO No.  Qty. 

Game Day Dble‐Wall Mason Jar  

1624‐31 BK  1589071  6 pcs 

1624‐31 BL  1790664  6 pcs 

1624‐31 RD  1773298  6 pcs 

Fiesta Ball 20oz with Straw 

SM‐6620 CL  M000002297  6 pcs 

SM‐6620 TLGR  P000077072  6 pcs 

SM‐6620 TRBL  M000006852  6 pcs 

Twister 16oz Tumbler with Straw  

SM‐6657 CL  M000007813  6 pcs 

SM‐6657 BK  M000004559  6 pcs 

SM‐6657 GR  P000080239  6 pcs 

SM‐6657 TRBL  M000007377  6 pcs 

Templar 22oz Tumbler 

SM‐6659 BL  M000004559  6 pcs 

SM‐6659 RE  M000004352  6 pcs 

SM‐6659 WH  M000007080  6 pcs 

Redondo 14oz Travel Tumbler  

SM‐6675 BL  M000002097  6 pcs 

SM‐6675 RE  M000003388  6 pcs 

SM‐6675 SI  M000003222  6 pcs 

Wrapper 16oz Tumbler SM‐6683 LM  P000082645  6 pcs 

SM‐6683 PBL  M000004559  6 pcs 

Hydra 22oz Tritan Sports Bottle  

SM‐6854 CL  P000069715  6 pcs 

SM‐6854 BL  P000069715  6 pcs 

SM‐6854 SM  P000069715  6 pcs 

Fountain Soda 24oz Tumbler  

SM‐6868 CL  M000004559  6 pcs 

SM‐6868 BK  P000077603  6 pcs 

SM‐6868 BL  M000002646  6 pcs 

Toto 16oz Travel Tumbler  SM‐6925 YL  M000005734  6 pcs 

Geo 20oz Travel Insulated Tumbler SM‐6440BK  M000003173  6 pcs

SM‐6440 SL  M000000982  6 pcs 

Vintage Dble‐Wall Mason Jar  1624‐33SGL  1770628  6 pcs

Page 4: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 4 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 ARTICLE/PO NO./ QUANTITY SUBMITTED DETAILED:   

Style description  Article No.  PO No.  Qty. 

Geo BPA Free Tritan Sprts Btle  

1624‐47BK  1793103  6 pcs

1624‐47BL  1792356  6 pcs

1624‐47CL  1781177  6 pcs

1624‐47LM  1792241  6 pcs

1624‐47OR  1794876  6 pcs

1626‐47PP  1786679  6 pcs

1624‐47RD  1795015  6 pcs

Hot & Cold Flip Geom Tumbler  

1624‐49BK  1785656  6 pcs 

1624‐49BL  1690748  6 pcs 

1624‐49CL  1787865  6 pcs 

1624‐49LM  1764996  6 pcs 

1624‐49PP  1776382  6 pcs 

1624‐49RD  1650545  6 pcs 

Geometric Vacuum Tumbler 1624‐51RGD  1766339  6 pcs 

1624‐51SL  1772061  6 pcs 

Geo Stainless Sport Bottle  1624‐60SGL  1715882  6 pcs 

Copper Vacuum Insulated Btle 

1624‐74SL  1756793  6 pcs 

1624‐74TI  1785672  6 pcs 

1624‐74GR  1762714  6 pcs 

1624‐74LM  1762641  6 pcs 

1624‐74RD  1790269  6 pcs

1624‐74NEBL  1759194  6 pcs

1624‐74NOR  1785319  6 pcs

1624‐74NPK  1755412  6 pcs

1624‐74NGR  1720051  6 pcs

1624‐74RGD  1770345  6 pcs

Page 5: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 5 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 ARTICLE/PO NO./ QUANTITY SUBMITTED DETAILED:   

Style description  Article No.  PO No.  Qty. 

Torino 15oz Tumbler 

SM‐6840 RD  M000004559  6 pcs 

SM‐6840 BK  M000007813  6 pcs 

SM‐6840 GR  M000004559  6 pcs 

SM‐6840 YL  M000005681  6 pcs 

SM‐6840 SL  M000004559  6 pcs 

Tailgate 16oz Party Cup 

SM‐6588 BL  P000082897  6 pcs 

SM‐6588 NY  M000008114  6 pcs 

SM‐6588 BK  M000005346  6 pcs 

SM‐6588 RD  M00000334  6 pcs 

Swivel Lid Stainless Tumbler  1624‐82 BL  1728060  6 pcs 

Growl Vac Keg Growler  1624‐88 SL  1773315  6 pcs 

Slash Iridescent Vacuum Tumbler  1624‐94 IR  1752479  6 pcs 

Mega Copper Vac Ins Btle 

1625‐13 BK  1782749  6 pcs 

1625‐13 NY  1770379  6 pcs 

1625‐13 SL  1790270  6 pcs 

1625‐13 RGD  1797532  6 pcs 

1625‐13 TI  1787102  6 pcs 

Hot & Cold Bloom Geo Tumbler 1625‐17 CL  1776623  6 pcs 

1625‐17 RYL  1716016  6 pcs 

Native Wooden Cop Vac Ins Btl  1625‐11 WD  1712610  6 pcs 

Hot & Cold Celebration Tumbler  1625‐12 MT  1793943  6 pcs 

Marble Copper Vac Ins Bottle  1625‐14 WH  1713829  6 pcs 

Victor Copper Vac Tblr w/open 

1625‐24 BK  1720757  6 pcs 

1625‐24 LM  1720753  6 pcs 

1625‐24 NY  1720756  6 pcs 

1625‐24 SL  1722537  6 pcs 

1625‐24 WH  1720755  6 pcs 

Victor Copper Vac Tblr w/open ‐ Opener  ‐  ‐  11 pcs 

Page 6: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 6 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

ARTICLE/PO NO./ QUANTITY SUBMITTED DETAILED:   

Style description  Article No.  PO No.  Qty. 

Hot & Cold Flip Cop Vac Tblr 

1625‐29 BK  1701138  6 pcs 

1625‐29 BL  1707036  6 pcs 

1625‐29 LM  1712440  6 pcs 

1625‐29 RD  1701140  6 pcs 

Valholla Cop Vac Mug w/ Cork 

1625‐48 BK  1792257  6 pcs 

1625‐48 GY  1739308  6 pcs 

1625‐48 NY  1758190  6 pcs 

1625‐48 SL  1765029  6 pcs 

Sauron 22oz Tumbler with Straw 

SM‐6670 CL  M000006345  6 pcs 

SM‐6670 BK  M000005346  6 pcs 

SM‐6670 BL  M000002614  6 pcs 

SM‐6670 RE  M000001321  6 pcs 

HideAway 16oz Tritan Sports Bottle SM‐6856 GR  P000058833  6 pcs 

SM‐6856 RD  P000058638  6 pcs 

Corzo Copper Vacuum Insulated Cup  

1625‐53 SL  1795100  6 pcs 

1625‐53 WH  1793423  6 pcs 

1625‐53 NY  1796610  6 pcs 

1625‐53 BK  1796560  6 pcs 

1625‐53 MTGR  1790628  6 pcs 

1625‐53 GY  1790667  6 pcs 

1625‐53 PBL  1790629  6 pcs 

1625‐53 RD  1790746  6 pcs 

Pinto Copper Vacuum Insulated Bottle 

1625‐65 BK  1774804  6 pcs 

1625‐65 GY  1762485  6 pcs 

1625‐65 SL  1731156  6 pcs 

1625‐65 WH  1771169  6 pcs 

1625‐65 NY  1789374  6 pcs 

Page 7: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 7 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 ARTICLE/PO NO./ QUANTITY SUBMITTED DETAILED:  

Style description  Article No.  PO No.  Qty. 

Valholla Cop Vac Tmbr w/ Cork 

1625‐69 BK  1791522  6 pcs 

1625‐69 GY  1777630  6 pcs 

1625‐69 NY  1777631  6 pcs 

1625‐69 SL  1783666  6 pcs 

1625‐69 WH  1781550  6 pcs 

Rover Copper Vacuum Insulated Camp Mug 

1625‐76 BK  1795149  6 pcs 

1625‐76 GY  1796855  6 pcs 

1625‐76 NY  1795151  6 pcs 

1625‐76 WH  1792878  6 pcs 

1625‐76 SL  1785924  6 pcs 

Iridescent Tumbler 

1625‐91BK  1796540  6 pcs 

1625‐911BL  1796539  6 pcs 

1625‐91WH  1796538  6 pcs 

Vasa Copper Vacuum Insulated Bottle 

1625‐96 BK  1775441  6 pcs 

1625‐96 NY  1778584  6 pcs 

1625‐96 SL  1785356  6 pcs 

1625‐96 WH  1790267  6 pcs 

Cutter & Buck® Bainbridge Copper Vac Bottle 9870‐11 CR  1793121  6 pcs 

Sedici Mega Acrylic Tumbler  1622‐98 CL  1787118  6 pcs 

Growl Stainless Pint Glass  1624‐39 SL  1794682  6 pcs 

Geometric Tumbler 

1624‐69 BK  1771016  6 pcs 

1624‐69 BL  1795066  6 pcs 

1624‐69 CL  1706447  6 pcs 

Hot & Cold Clarity Drop Tumbler 1624‐87 RD  1703619  6 pcs 

1624‐87 RYL  1701670  6 pcs 

Geometric Stainless Bottle 

1625‐18 BL  1788575  6 pcs 

1625‐18 GA  1749531  6 pcs 

1625‐18 RD  1715511  6 pcs 

1625‐18 SL  1692089  6 pcs 

Page 8: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 8 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

ARTICLE/PO NO./ QUANTITY SUBMITTED DETAILED:  

Style description  Article No.  PO No.  Qty. 

Bellagio Copper Vac Insulated Flask 

1625‐19 BK  1694939  6 pcs 

1625‐19 BL  1694938  6 pcs 

1625‐19 LM  1712265  6 pcs 

1625‐19 SL  1692096  6 pcs 

Aurora Copper Vacuum Insulated Bottle 

1625‐26 IRBL  1712476  6 pcs 

1625‐26 IRGD  1701149  6 pcs 

1625‐26 IRGR  1775356  6 pcs 

1625‐26 IRWH  1764768  6 pcs 

Duke Copper Vacuum Insulated Bottle 

1625‐27 BK  1726270  6 pcs 

1625‐27 GY  1775709  6 pcs 

1625‐27 RYL  1712472  6 pcs 

1625‐27 SL  1727838  6 pcs 

1625‐27 WH  1781209  6 pcs 

Copper Vacuum Flask w/ Ceramic Lining 1625‐32 BL  1720777  6 pcs 

1625‐32 SL  1720778  6 pcs 

Tugo Copper Vac Tumbler & Can Insulator  1625‐37 SL  1713385  6 pcs 

Glacier Copper Vacuum Tumbler 

1625‐99 BK  1798456  6 pcs 

1625‐99 BL  1775084  6 pcs 

1625‐99 MDBL  1796154  6 pcs 

1625‐99 SL  1775087  6 pcs 

1625‐99 TI  1775083  6 pcs 

1625‐99 WH  1802354  6 pcs 

Norse Copper Vacuum Insulated Bottle 

1626‐01 BK  1775076  6 pcs 

1626‐01 GM  1775072  6 pcs 

1626‐01 GY  1775074  6 pcs 

1626‐01 NY  1775078  6 pcs 

1626‐01 SL  1775079  6 pcs 

1626‐01 WH  1775077  6 pcs 

Page 9: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 9 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 ARTICLE/PO NO./ QUANTITY SUBMITTED DETAILED:  

Style description  Article No.  PO No.  Qty. 

Speckled Vasa Copper Vacuum Insulated Bottle 

1626‐11 BK  1775049  6 pcs 

1626‐11 HG  1775044  6 pcs 

1626‐11 NY  1775045  6 pcs 

1626‐11 WH  1775046  6 pcs 

Bumble Copper Vacuum Insulated Bottle 

1626‐12 BK  1781137  6 pcs 

1626‐12 GM  1781139  6 pcs 

1626‐12 SL  1796562  6 pcs 

Bumble Copper Vacuum Insulated Cup 

1626‐13 BK  1781135  6 pcs 

1626‐13 GM  1781131  6 pcs 

1626‐13 NY  1771133  6 pcs 

1626‐13 SL  1781128  6 pcs 

1626‐13 WH  1781130  6 pcs 

Thor Copper Vacuum Insulated Tumbler 

1626‐50 BK  1798106  6 pcs 

1626‐50 GY  1798107  6 pcs 

1626‐50 MTGR  1788074  6 pcs 

1626‐50 NY  1798109  6 pcs 

1626‐50 OR  1788076  6 pcs 

1626‐50 PBL  1788078  6 pcs 

1626‐50 RD  1792112  6 pcs 

1626‐50 SL  1798113  6 pcs 

1626‐50 WH  1798114  6 pcs 

Valhalla Copper Vacuum Insulated Bottle 

1626‐58 BK  1798361  6 pcs 

1626‐58 GY  1798357  6 pcs 

1626‐58 NY  1798358  6 pcs 

1626‐58 SL  1798362  6 pcs 

1626‐58 WH  1798359  6 pcs 

Page 10: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 10 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

ARTICLE/PO NO./ QUANTITY SUBMITTED DETAILED:  

Style description  Article No.  PO No.  Qty. 

Coco Ice Cool Tumbler 

1626‐61 BK  1796454  6 pcs 

1626‐61 BL  1796455  6 pcs 

1626‐61 CL  1796456  6 pcs 

1626‐61 GR  1796453  6 pcs 

1626‐61 RD  1796452  6 pcs 

Page 11: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 11 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

TEST RESULTS SUMMARY: 

 At the request of the client, the following tests were conducted:  

CONCLUSION  TEST(S) CONDUCTED 

PASS  CPSIA Section 101 & 16 CFR 1303, Total Lead in Paints and Surface Coatings 

PASS  California Proposition 65, Total Lead in Paints and Surface Coatings 

PASS  California Proposition 65, Total Lead in Substrate Materials 

PASS  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP) 

PASS  FDA GRAS Specifications, Total Chromium in Stainless Steel Food Containers# 

PASS  Client’s Requirement, Bisphenol A# 

PASS  FDA 21 CFR 175.300, Resinous and Polymeric Coatings# 

PASS  FDA 21 CFR 177.1210, Closures with Sealing Gaskets# 

PASS  FDA 21 CFR 177.1520, Polypropylene Copolymers 

PASS  FDA 21 CFR 177.1520, Polyethylene Homopolymers 

PASS  FDA 21 CFR 177.1520, Polypropylene Homopolymers 

PASS  FDA 21 CFR 177.1630, Polyethylene Phthalate Polymers 

PASS  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers 

PASS  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Butadiene/Styrene Copolymers 

PASS Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim 

PASS Canadian Surface Coating Materials Regulations SOR/2016‐193, Total Lead in Surface Coating Materials 

PASS Canadian Consumer Products Containing Lead Regulations (SOR/2018‐83), Total Lead Content 

 

  

 

   

Page 12: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 12 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 CPSIA Section 101 & 16 CFR 1303, Total Lead in Paints and Surface Coatings  Test Method:  CPSC‐CH‐E‐1003‐09.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  77+78+79  80+81+82  84+85  89 139+140 +141 

Total 

Test Item Result (ppm) 

Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  142+143  144+145 178+179 +180 

181+182 +183 

184+185 +186 

Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS 

 

Specimen No. 187+188 +189 

190  191 222+223 +224 

225+226 +227 

Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS 

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not detected (Reporting Limit = 20 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration. 

   

Page 13: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 13 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 CPSIA Section 101 & 16 CFR 1303, Total Lead in Paints and Surface Coatings  Test Method:  CPSC‐CH‐E‐1003‐09.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No. 228+229 +230 

231+232  233+234  235 236+237 +238 

Total 

Test Item Result (ppm) 

Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS 

 

Specimen No. 239+240 +241 

242+243 +244 

245+246 +247 

248+249 +250 

251+252  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  25  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  253+254  ‐‐‐  ‐‐‐  ‐‐‐  ‐‐‐  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ‐‐‐  ‐‐‐  ‐‐‐  ‐‐‐  90 

Conclusion  PASS  ‐‐‐  ‐‐‐  ‐‐‐  ‐‐‐ 

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not detected (Reporting Limit = 20 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration. 

   

Page 14: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 14 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 California Proposition 65, Total Lead in Paints and Surface Coatings  Test Method:  CPSC‐CH‐E‐1003‐09.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  77+78+79  80+81+82  84+85  89 139+140 +141 

Total 

Test Item Result (ppm) 

Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  142+143  144+145 178+179 +180 

181+182 +183 

184+185 +186 

Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS 

 

Specimen No. 187+188 +189 

190  191 222+223 +224 

225+226 +227 

Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS 

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than 

ND = Not detected (Reporting Limit = 20 ppm) 

Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 15: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 15 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 California Proposition 65, Total Lead in Paints and Surface Coatings  Test Method:  CPSC‐CH‐E‐1003‐09.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No. 228+229 +230 

231+232  233+234  235 236+237 +238 

Total 

Test Item Result (ppm) 

Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS 

 

Specimen No. 239+240 +241 

242+243 +244 

245+246 +247 

248+249 +250 

251+252  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  25  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  253+254  ‐‐‐  ‐‐‐  ‐‐‐  ‐‐‐  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ‐‐‐  ‐‐‐  ‐‐‐  ‐‐‐  90 

Conclusion  PASS  ‐‐‐  ‐‐‐  ‐‐‐  ‐‐‐ 

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than 

ND = Not detected (Reporting Limit = 20 ppm) 

Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 16: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 16 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Total Lead in Substrate Materials  Test Method:  CPSC‐CH‐E1001‐08.3 (Metal), CPSC‐CH‐E1002‐08.3 (Non‐Metal) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  7+8+9  10+11+12  13+14+15  16+17+18  19+20+21  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No.  22+23+24  25+26  27+28  29+30+31  32+33+34  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No.  35+36+37  38+39+40  41+42+43  44+45+46  47+48+49  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than 

ND = Not detected (Reporting Limit = 20 ppm) 

Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 17: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 17 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Total Lead in Substrate Materials  Test Method:  CPSC‐CH‐E1001‐08.3 (Metal), CPSC‐CH‐E1002‐08.3 (Non‐Metal) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry 

 

Specimen No.  50+51  52+53+54  55+56  57+58+59  60+61  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No.  62+63  74  76  94+95+96  97+98+99  Total 

Test Item Result (ppm) 

Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No. 100+101 +102 

103+104 +105 

106+107  108+109 110+111 +112 

Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than 

ND = Not detected (Reporting Limit = 20 ppm) 

Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 18: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 18 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Total Lead in Substrate Materials  Test Method:  CPSC‐CH‐E1001‐08.3 (Metal), CPSC‐CH‐E1002‐08.3 (Non‐Metal) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry 

 

Specimen No. 113+114 +115 

116+117  118+119  120  121  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No. 122+123 +124 

136  137 146+147 +148 

149+150 +151 

Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No.  152+153  154+155  156+157  158+159  160+161  Total 

Test Item Result (ppm) 

Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than 

ND = Not detected (Reporting Limit = 20 ppm) 

Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 19: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 19 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Total Lead in Substrate Materials  Test Method:  CPSC‐CH‐E1001‐08.3 (Metal), CPSC‐CH‐E1002‐08.3 (Non‐Metal) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry 

 

Specimen No.  162+163  192+193  194+195 196+197 +198 

200  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No.  201  202  208  210  211  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No.  212  213 259+260261 

262+263 264+265 +266 

Total 

Test Item Result (ppm) 

Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than 

ND = Not detected (Reporting Limit = 20 ppm) 

Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 20: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 20 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Total Lead in Substrate Materials  Test Method:  CPSC‐CH‐E1001‐08.3 (Metal), CPSC‐CH‐E1002‐08.3 (Non‐Metal) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry 

 

Specimen No. 267+268 +269 

270+271 +272 

273+274 +275 

276  277  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No.  278  279+280  290  291  304  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  100 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No.  305  307 334+335+336 

‐‐‐  ‐‐‐  Total 

Test Item Result (ppm) 

Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Total Lead (Pb)  ND  ND  ND  ‐‐‐  ‐‐‐  100 

Conclusion  PASS  PASS  PASS  ‐‐‐  ‐‐‐   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than 

ND = Not detected (Reporting Limit = 20 ppm) 

Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 21: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 21 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  7+8+9  10+11+12  13+14+15  16+17+18   

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 22: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 22 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  19+20+21  22+23+24  25+26  27+28   

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 23: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 23 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  29+30+31  32+33+34  35+36+37  38+39+40   

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 24: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 24 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  41+42+43  44+45+46  47+48+49  50+51   

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 25: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 25 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  52+53+54  55+56  57+58+59  60+61   

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 26: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 26 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  62+63  77+78+79  80+81+82  84+85   

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement.    

Page 27: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 27 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  89  94+95+96  97+98+99 100+101 +102 

 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement.    

Page 28: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 28 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No. 103+104+105 

106+107  108+109 110+111 +112 

 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement.    

Page 29: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 29 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No. 113+114+115 

116+117  118+119  120   

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement.    

Page 30: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 30 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  121 122+123+124 

136  137   

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  290  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement.    

Page 31: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 31 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No. 139+140+141 

142+143  144+145 146+147 +148 

 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  290  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  270  200  230  180  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement.    

Page 32: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 32 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No. 149+150+151 

152+153  154+155  156+157   

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  170  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement.    

Page 33: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 33 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  158+159  160+161  162+163 178+179 +180 

 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 34: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 34 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No. 181+182+183 

184+185+186 

187+188+189 

190   

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  LT 170  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  LT 170  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  LT 170  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  LT 170  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  LT 170  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  LT 170  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement.    

Page 35: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 35 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  191  192+193  194+195 196+197 +198 

 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 36: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 36 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  200  201  202  208   

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 37: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 37 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  210  211  212 222+223 +224 

 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  210  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 38: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 38 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No. 225+226+227 

228+229+230 

231+232  233+234   

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 39: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 39 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  235 236+237+238 

239+240+241 

242+243 +244 

 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 40: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 40 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No. 245+246+247 

248+249+250 

251+252  253+254   

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 41: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 41 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No. 259+260+261 

262+263 264+265+266 

267+268 +269 

 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 42: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 42 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No. 270+271+272 

273+274+275 

276  277   

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 43: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 43 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No.  278  279+280  290  291   

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ND  ND  ND  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ND  ND  ND  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ND  ND  ND  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ND  ND  ND  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ND  ND  ND  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ND  ND  ND  1000 

Conclusion  PASS  PASS  PASS  PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 44: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 44 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  California Proposition 65, Phthalates (DBP, BBP, DEHP, DINP, DIDP, DnHP)  Test Method:  CPSC‐CH‐C1001‐09.3 Analytical Method:  Gas Chromatography with Mass Spectrometry

 

Specimen No. 334+335+336 

‐‐‐  ‐‐‐  ‐‐‐   

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Dibutyl phthalate (DBP) 

84‐74‐2  ND  ‐‐‐  ‐‐‐  ‐‐‐  1000 

Benzyl butyl phthalate (BBP) 

85‐68‐7  ND  ‐‐‐  ‐‐‐  ‐‐‐  1000 

Di‐(2‐ethylhexyl) phthalate (DEHP) 

117‐81‐7  ND  ‐‐‐  ‐‐‐  ‐‐‐  1000 

Diisononyl phthalate (DINP) 

28553‐12‐0 68515‐48‐0 

ND  ‐‐‐  ‐‐‐  ‐‐‐  1000 

Diisodecyl phthalate (DIDP) 

26761‐40‐0 68515‐49‐1 

ND  ‐‐‐  ‐‐‐  ‐‐‐  1000 

Di‐n‐hexyl phthalate (DnHP) 

84‐75‐3  ND  ‐‐‐  ‐‐‐  ‐‐‐  1000 

Conclusion  PASS  ‐‐‐  ‐‐‐  ‐‐‐   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 120 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.  Remark: The specification is quoted from client’s requirement. 

   

Page 45: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 45 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS: 

 

FDA GRAS Specifications, Total Chromium in Stainless Steel Food Containers 

 Test Method:  In‐House Method#

Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry 

Specimen No.  73  306  ‐‐‐  ‐‐‐  ‐‐‐ 

Test Item Result (% m/m) 

Result (% m/m) 

Result (% m/m) 

Result (% m/m) 

Result (% m/m) 

Limit (% m/m) 

Total Chromium (Cr)  16.5  18.2  ‐‐‐  ‐‐‐  ‐‐‐  GT 16 

Conclusion  PASS  PASS  ‐‐‐  ‐‐‐  ‐‐‐ 

 Note: % m/m = Percent by mass GT = Greater than  Remark: The limit is quoted from ANSI/NSF 51‐1997 Section 7.1.2. 

   

Page 46: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 46 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Bisphenol A  Test Method:  In‐House Method#

Analytical Method:  Liquid Chromatography with Fluorescence Detection 

Specimen No.  1  2  3  4 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  5  6  7  8 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  9  10  11  12 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  13  14  15  16 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not Detected (Reporting Limit = 1 ppm) 

   

Page 47: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 47 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Bisphenol A  Test Method:  In‐House Method#

Analytical Method:  Liquid Chromatography with Fluorescence Detection 

Specimen No.  17  18  19  20 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  21  22  23  24 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  25  26  27  28 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  29  30  31  32 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not Detected (Reporting Limit = 1 ppm) 

   

Page 48: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 48 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Bisphenol A  Test Method:  In‐House Method#

Analytical Method:  Liquid Chromatography with Fluorescence Detection 

Specimen No.  33  34  35  36 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  37  38  39  40 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  57  58  59  60 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  61  62  63  92 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not Detected (Reporting Limit = 1 ppm) 

   

Page 49: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 49 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Bisphenol A  Test Method:  In‐House Method#

Analytical Method:  Liquid Chromatography with Fluorescence Detection 

Specimen No.  93  94  95  96 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  97  98  99  100 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  101  102  103  104 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  105  106  107  121 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not Detected (Reporting Limit = 1 ppm) 

   

Page 50: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 50 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Bisphenol A  Test Method:  In‐House Method#

Analytical Method:  Liquid Chromatography with Fluorescence Detection 

Specimen No.  122  123  124  136 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  146  147  148  149 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  150  151  162  163 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  192  193  194  195 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not Detected (Reporting Limit = 1 ppm) 

   

Page 51: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 51 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Bisphenol A  Test Method:  In‐House Method#

Analytical Method:  Liquid Chromatography with Fluorescence Detection 

Specimen No.  200  201  202  208 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  210  211  212  241 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  255  256  257  258 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not Detected (Reporting Limit = 1 ppm) 

   

Page 52: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 52 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Bisphenol A  Test Method:  In‐House Method#

Analytical Method:  Liquid Chromatography with Fluorescence Detection 

Specimen No.  259  263  264  265 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  266  267  268  281 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS 

 

Specimen No.  290  291  334  335 

Test Item  CAS No. Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Bisphenol A (BPA)  80‐05‐7  ND  ND  ND  ND  ND 

Conclusion  PASS  PASS  PASS  PASS   

 

Specimen No.  336  ‐‐‐  ‐‐‐  ‐‐‐ 

Test Item  CAS No. Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Bisphenol A (BPA)  80‐05‐7  PASS  ‐‐‐  ‐‐‐  ‐‐‐  ND 

Conclusion  PASS  ‐‐‐  ‐‐‐  ‐‐‐   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not Detected (Reporting Limit = 1 ppm) 

   

Page 53: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 53 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 175.300, Resinous and Polymeric Coatings  Test Method:  FDA 21 CFR 175.300#

 

Specimen No.  241  ‐‐‐     

Test Item Test Condition Result 

(mg/in2) Result (mg/in2) 

RL (mg/in2) 

Limit (mg/in2) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

0.23  ‐‐‐  0.1  18 

    Conclusion  PASS  ‐‐‐   

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 175.300 (c) (3). 

    

Page 54: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 54 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  66  68     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  69  125     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  126  127     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 2.   

   

Page 55: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 55 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  163  165     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  167  168     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  18  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  169  172     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  11  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 2.      

Page 56: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 56 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  199  200     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  202  203     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  206  209     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 2. 

   

Page 57: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 57 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  281  282     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  284  285     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  286  287     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 2. 

   

Page 58: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 58 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  288  289     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  290  291     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  292  293     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 2. 

   

Page 59: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 59 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  294  298     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  299  300     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  301  ‐‐‐     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ‐‐‐  10  50 

    Conclusion  PASS  ‐‐‐     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 2. 

   

Page 60: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 60 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  121  162     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  201  ‐‐‐     

Test Item Test Condition  Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  Fill boiling Until Cool to 100OF 

ND  ‐‐‐  10  50 

    Conclusion  PASS  ‐‐‐     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 3. 

   

Page 61: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 61 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  64  65     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  67  70     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  71  72     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 2.  

   

Page 62: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 62 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  128  129     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  138  164     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  166  170     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 2.  

   

Page 63: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 63 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  171  204     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  205  207     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  283  295     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 2. 

   

Page 64: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 64 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  296  297     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  302  303     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 2. 

   

Page 65: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 65 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  58  59     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  60  61     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  62  63     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 3.     

Page 66: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 66 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  122  123     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  124  208     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 

Specimen No.  210  211     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ND  10  50 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 3. 

   

Page 67: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 67 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 

DETAILED RESULTS: 

 FDA 21 CFR 177.1210, Closures with Sealing Gaskets  Test Method:  FDA 21 CFR 177.1210#

 

Specimen No.  212  ‐‐‐     

Test Item Test Condition Result 

(ppm) Result (ppm) 

RL (ppm) 

Limit (ppm) Temp.  Duration 

Distilled water extractive  120°F  24 hours  ND  ‐‐‐  10  50 

    Conclusion  PASS  ‐‐‐     

 Note: Temp. = Temperature °F = Degree Fahrenheit ppm (Parts per million) = mg/kg (Milligrams per kilogram foodstuff) LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1210 Table 2 Section 3. 

   

Page 68: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 68 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polypropylene Copolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  4  5     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.913  0.894  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  1.5  1.0  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

4.5  3.1  1.0  30 

    Conclusion  PASS  PASS     

 

Specimen No.  12  13     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.901  0.905  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  2.1  1.5  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

5.1  4.0  1.0  30 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 3.1a. 

   

Page 69: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 69 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polypropylene Copolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  14  15     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.902  0.902  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  1.1  1.4  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

3.5  4.0  1.0  30 

    Conclusion  PASS  PASS     

 

Specimen No.  16  17     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.902  0.903  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  1.0  1.1  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

3.3  2.7  1.0  30 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 3.1a. 

   

Page 70: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 70 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polypropylene Copolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  18  19     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.903  0.903  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  1.0  1.2  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

3.8  3.8  1.0  30 

    Conclusion  PASS  PASS     

 

Specimen No.  20  21     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.900  0.908  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  0.7  ND  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

1.0  2.6  1.0  30 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 3.1a. 

   

Page 71: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 71 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polypropylene Copolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  22  23     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.900  0.905  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  0.6  1.8  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

4.3  2.0  1.0  30 

    Conclusion  PASS  PASS     

 

Specimen No.  24  25     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.896  0.905  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  0.7  0.9  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

6.2  2.8  1.0  30 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 3.1a. 

   

Page 72: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 72 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polypropylene Copolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  26  27     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.905  0.906  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  0.9  0.9  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

1.8  2.5  1.0  30 

    Conclusion  PASS  PASS     

 

Specimen No.  28  29     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.901  0.900  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  0.8  1.7  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

2.5  4.0  1.0  30 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 3.1a. 

   

Page 73: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 73 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polypropylene Copolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  30  31     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.905  0.901  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  0.7  2.1  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

2.3  7.1  1.0  30 

    Conclusion  PASS  PASS     

 

Specimen No.  93  94     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.896  0.899  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  1.1  0.6  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

1.7  2.2  1.0  30 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 3.1a. 

   

Page 74: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 74 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polypropylene Copolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  95  146     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.900  0.907  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  0.8  0.4  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

5.1  1.8  1.0  30 

    Conclusion  PASS  PASS     

 

Specimen No.  147  193     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.902  0.902  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  1.0  0.5  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

3.8  1.1  1.0  30 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 3.1a.    

Page 75: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 75 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polypropylene Copolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  194  255     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.905  0.937  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  0.6  1.2  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

1.4  8.0  1.0  30 

    Conclusion  PASS  PASS     

 

Specimen No.  256  257     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.921  0.925  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  0.8  0.4  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

8.2  7.5  1.0  30 

    Conclusion  PASS  PASS     

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 3.1a.    

Page 76: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 76 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polypropylene Copolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  263  ‐‐‐     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.900  ‐‐‐  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  1.2  ‐‐‐  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

4.7  ‐‐‐  1.0  30 

    Conclusion  PASS  ‐‐‐     

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 3.1a.    

Page 77: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 77 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polyethylene Homopolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  259  ‐‐‐     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.917  ‐‐‐  NA  0.85‐1.00 

n‐Hexane extractive (%)  50°C  2 hours  1.1  ‐‐‐  0.4  5.5 

Xylene extractive (%)   Reflux 2 hours or until total dissolved 

4.7  ‐‐‐  1.0  11.3 

    Conclusion  PASS  ‐‐‐   

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 2.1. 

   

Page 78: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 78 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1520, Polypropylene Homopolymers  Test Method:  FDA 21 CFR 177.1520 

 

Specimen No.  334  335     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.896  0.903  NA 0.880 – 0.913 

Melting point (oC)  NA  NA  169.2  168.9  NA  150 – 180 

n‐Hexane extractive (%)  Reflux  2 hours  3.5  1.1  0.1  6.4 

Xylene extractive (%)  120°C 2 hours or until total dissolved 

1.5  2.0  0.5  9.8 

    Conclusion  PASS  PASS     

 

Specimen No.  336  ‐‐‐     

Test Item  Temp.  Duration  Result  Result  RL  Limit 

Density (g/cc)  NA  NA  0.898  ‐‐‐  NA 0.880 – 0.913 

Melting point (oC)  NA  NA  169.3  ‐‐‐  NA  150 – 180 

n‐Hexane extractive (%)  Reflux  2 hours  1.6  ‐‐‐  0.1  6.4 

Xylene extractive (%)  120°C 2 hours or until total dissolved 

2.2  ‐‐‐  0.5  9.8 

    Conclusion  PASS  ‐‐‐     

 Note: Temp. = Temperature °C = Degree Celsius g/cc = Grams per cubic centimeter % w/w = Percent by weight NA = Not applicable LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1520 (c) 1.1. 

Page 79: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 79 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1630, Polyethylene Phthalate Polymers  Test Method:  FDA 21 CFR 177.1630 

 

Specimen No.  32     

Test Item Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  2500F  2 hours  ND  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 

Specimen No.  33     

Test Item Test Condition 

Result  RL  Limit Temp. Duration

Distilled water extractive (mg/in2)  2500F  2 hours  ND  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1630 (f). 

   

Page 80: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 80 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1630, Polyethylene Phthalate Polymers  Test Method:  FDA 21 CFR 177.1630 

 

Specimen No.  34     

Test Item Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  2500F  2 hours  ND  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 

Specimen No.  96     

Test Item Test Condition 

Result  RL  Limit Temp. Duration

Distilled water extractive (mg/in2)  2500F  2 hours  ND  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1630 (f).    

Page 81: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 81 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1630, Polyethylene Phthalate Polymers  Test Method:  FDA 21 CFR 177.1630 

 

Specimen No.  97     

Test Item Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  2500F  2 hours  ND  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 

Specimen No.  98     

Test Item Test Condition 

Result  RL  Limit Temp. Duration

Distilled water extractive (mg/in2)  2500F  2 hours  ND  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1630 (f).    

Page 82: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 82 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1630, Polyethylene Phthalate Polymers  Test Method:  FDA 21 CFR 177.1630 

 

Specimen No.  99     

Test Item Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  2500F  2 hours  0.1  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 

Specimen No.  100     

Test Item Test Condition 

Result  RL  Limit Temp. Duration

Distilled water extractive (mg/in2)  2500F  2 hours  ND  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1630 (f).    

Page 83: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 83 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1630, Polyethylene Phthalate Polymers  Test Method:  FDA 21 CFR 177.1630 

 

Specimen No.  101     

Test Item Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  2500F  2 hours  ND  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 

Specimen No.  151     

Test Item Test Condition 

Result  RL  Limit Temp. Duration

Distilled water extractive (mg/in2)  2500F  2 hours  ND  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1630 (f).    

Page 84: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 84 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 177.1630, Polyethylene Phthalate Polymers  Test Method:  FDA 21 CFR 177.1630 

 

Specimen No.  195     

Test Item Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  2500F  2 hours  0.1  0.1  0.5 

n‐Heptane extractive (mg/in2)  1500F  2 hours  ND  0.1  0.5 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 177.1630 (f).    

Page 85: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 85 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  1     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  2     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

  Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 86: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 86 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  3     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS   

 

Specimen No.  6     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

  Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 87: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 87 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  7     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  8     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

  Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 88: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 88 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  9     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  10     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

  Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 89: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 89 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  11     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  92     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

  Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 90: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 90 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  102     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  103     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

  Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3).    

Page 91: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 91 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  104     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  136     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

  Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3).    

Page 92: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 92 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  148     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  149     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

  Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3).    

Page 93: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 93 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  192     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  258     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3).    

Page 94: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 94 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  264     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  265     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 95: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 95 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Butadiene/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  35     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  36     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 96: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 96 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Butadiene/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  37     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  38     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 97: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 97 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Butadiene/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  39     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  40     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 98: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 98 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Butadiene/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  105     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  106     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 99: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 99 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Butadiene/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  107     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  150     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 100: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 100 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Butadiene/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  266     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 

Specimen No.  267     

Test Simulant Test Condition

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 101: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 101 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  FDA 21 CFR 180.22 and 181.32, Acrylonitrile/Butadiene/Styrene Copolymers  Test Method:  FDA 21 CFR 180.22 and 181.32 Analytical Method:  Headspace‐Gas Chromatography with Mass Spectrometry

 Acrylonitrile Monomers:  

Specimen No.  268     

Test Simulant Test Condition 

Result  RL  Limit Temp.  Duration 

Distilled water extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

3% Acetic acid extractive (mg/in2)  120oF  2 hours  ND  0.001  0.003 

Conclusion  PASS     

 Note: Temp. = Temperature °F = Degree Fahrenheit mg/in2 = Milligrams per square inch LT = Less than ND = Not detected.  Result value is less than reporting limit (RL).  Remark: The specification is quoted from 21 CFR 181.32 (b) (3). 

   

Page 102: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 102 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  135A  135B  135C  135D  135E  135F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

200  200  200  200  200  200   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  173A  173B  173C  173D  173E  173F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 103: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 103 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  174A  174B  174C  174D  174E  174F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  175A  175B  175C  175D  175E  175F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 104: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 104 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  176A  176B  176C  176D  176E  176F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  177A  177B  177C  177D  177E  177F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 105: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 105 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  214A  214B  214C  214D  214E  214F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  215A  215B  215C  215D  215E  215F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 106: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 106 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  216A  216B  216C  216D  216E  216F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  217A  217B  217C  217D  217E  217F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 107: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 107 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  218A  218B  218C  218D  218E  218F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  219A  219B  219C  219D  219E  219F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 108: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 108 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  220A  220B  220C  220D  220E  220F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  221A  221B  221C  221D  221E  221F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 109: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 109 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  308A  308B  308C  308D  308E  308F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  309A  309B  309C  309D  309E  309F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 110: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 110 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  310A  310B  310C  310D  310E  310F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  311A  311B  311C  311D  311E  311F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 111: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 111 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  312A  312B  312C  312D  312E  312F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

250  250  250  250  250  250   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  313A  313B  313C  313D  313E  313F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

250  250  250  250  250  250   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 112: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 112 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  314A  314B  314C  314D  314E  314F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

250  250  250  250  250  250   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  315A  315B  315C  315D  315E  315F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

250  250  250  250  250  250   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 113: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 113 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  316A  316B  316C  316D  316E  316F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

250  250  250  250  250  250   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  317A  317B  317C  317D  317E  317F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

250  250  250  250  250  250   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 114: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 114 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  318A  318B  318C  318D  318E  318F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  319A  319B  319C  319D  319E  319F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 115: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 115 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  320A  320B  320C  320D  320E  320F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  321A  321B  321C  321D  321E  321F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 116: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 116 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  322A  322B  322C  322D  322E  322F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  323A  323B  323C  323D  323E  323F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 117: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 117 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  324A  324B  324C  324D  324E  324F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  325A  325B  325C  325D  325E  325F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

210  210  210  210  210  210   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 118: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 118 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  326A  326B  326C  326D  326E  326F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  327A  327B  327C  327D  327E  327F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 119: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 119 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  328A  328B  328C  328D  328E  328F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  329A  329B  329C  329D  329E  329F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

220  220  220  220  220  220   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 120: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 120 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  330A  330B  330C  330D  330E  330F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

250  250  250  250  250  250   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  331A  331B  331C  331D  331E  331F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

250  250  250  250  250  250   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 121: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 121 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Client’s Requirement, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim  Test Method:  ASTM C927‐80(2014) Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  332A  332B  332C  332D  332E  332F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

250  250  250  250  250  250   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 

Specimen No.  333A  333B  333C  333D  333E  333F   

Test Item Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Result (mg/L) 

Limit (mg/L) 

Volume of acid used (mL) 

250  250  250  250  250  250   

Leachable Cadmium (Cd) 

ND  ND  ND  ND  ND  ND  0.4 

Leachable Lead (Pb)  ND  ND  ND  ND  ND  ND  4.0 

Conclusion  PASS  PASS  PASS  PASS  PASS  PASS 

 Note: mL = Millilitres mg/L (Milligrams per litre) = ppm (Parts per million) NA = Not applicable LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04 mg/L; Cd = 0.02 mg/L)  Remark: The limit is quoted from Society of Glass & Ceramic Decorated Products. 

   

Page 122: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 122 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Canadian Surface Coating Materials Regulations SOR/2016‐193, Total Lead in Surface Coating Materials  Test Method:  CPSC‐CH‐E‐1003‐09.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  77+78+79  80+81+82  84+85  89 139+140 +141 

Total 

Test Item Result (ppm) 

Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No.  142+143  144+145 178+179 +180 

181+182 +183 

184+185 +186 

Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No. 187+188 +189 

190  191 222+223 +224 

225+226 +227 

Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not detected (Reporting Limit = 20 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration. 

       

Page 123: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 123 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Canadian Surface Coating Materials Regulations SOR/2016‐193, Total Lead in Surface Coating Materials  Test Method:  CPSC‐CH‐E‐1003‐09.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No. 228+229 +230 

231+232  233+234  235 236+237 +238 

Total 

Test Item Result (ppm) 

Result(ppm) 

Result(ppm) 

Result(ppm) 

Result (ppm) 

Limit(ppm) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS  PASS  PASS  PASS   

 

Specimen No. 239+240 +241 

242+243 +244 

245+246 +247 

248+249 +250 

251+252  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  25  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  253+254  ‐‐‐  ‐‐‐  ‐‐‐  ‐‐‐  Total 

Test Item Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Result (ppm) 

Limit (ppm) 

Total Lead (Pb)  ND  ‐‐‐  ‐‐‐  ‐‐‐  ‐‐‐  90 

Conclusion  PASS  ‐‐‐ ‐‐‐ ‐‐‐ ‐‐‐   

 Note: ppm (Parts per million) = mg/kg (Milligrams per kilogram) LT = Less than ND = Not detected (Reporting Limit = 20 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration. 

   

Page 124: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 124 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Canadian Consumer Products Containing Lead Regulations (SOR/2018‐83), Total Lead Content  Test Method:  ASTM F963‐17 Clause 8.3.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  7+8+9  10+11+12  13+14+15  16+17+18  19+20+21   

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  22+23+24  25+26  27+28  29+30+31  32+33+34   

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  35+36+37  38+39+40  41+42+43  44+45+46  47+48+49   

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  57+58+59  60+61  62+63  74  76   

Test Item Result (mg/kg) 

Result(mg/kg) 

Result(mg/kg) 

Result(mg/kg) 

Result (mg/kg) 

Limit(mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 Note: mg/kg (Milligrams per kilogram) = ppm (Parts per million) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 20 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.   

Page 125: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 125 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Canadian Consumer Products Containing Lead Regulations (SOR/2018‐83), Total Lead Content  Test Method:  ASTM F963‐17 Clause 8.3.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  77+78+79  80+81+82  84+85  89  94+95+96   

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  97+98+99 100+101 +102 

103+104 +105 

106+107  108+109   

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  121 122+123 +124 

136 139+140 +141 

142+143   

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  144+145 146+147+148 

149+150+151 

139+140+141 

142+143   

Test Item Result (mg/kg) 

Result(mg/kg) 

Result(mg/kg) 

Result(mg/kg) 

Result (mg/kg) 

Limit(mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 Note: mg/kg (Milligrams per kilogram) = ppm (Parts per million) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 20 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration. 

Page 126: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 126 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Canadian Consumer Products Containing Lead Regulations (SOR/2018‐83), Total Lead Content  Test Method:  ASTM F963‐17 Clause 8.3.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  144+145 146+147+148 

149+150+151 

152+153  154+155   

Test Item Result (mg/kg) 

Result(mg/kg) 

Result(mg/kg) 

Result(mg/kg) 

Result (mg/kg) 

Limit(mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  162+163 178+179 +180 

181+182 +183 

184+185 +186 

187+188 +189 

 

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  190  191  192+193  194+195  200   

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  201  202  208  210  211   

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 Note: mg/kg (Milligrams per kilogram) = ppm (Parts per million) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 20 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration. 

Page 127: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 127 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Canadian Consumer Products Containing Lead Regulations (SOR/2018‐83), Total Lead Content  Test Method:  ASTM F963‐17 Clause 8.3.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No.  212  213 222+223+224 

225+226+227 

228+229 +230 

 

Test Item Result (mg/kg) 

Result(mg/kg) 

Result(mg/kg) 

Result(mg/kg) 

Result (mg/kg) 

Limit(mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  231+232  233+234  235 236+237 +238 

239+240 +241 

 

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No. 242+243 +244 

245+246 +247 

248+249 +250 

251+252  253+254   

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  25  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 Note: mg/kg (Milligrams per kilogram) = ppm (Parts per million) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 20 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration. 

   

Page 128: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 128 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 DETAILED RESULTS:  Canadian Consumer Products Containing Lead Regulations (SOR/2018‐83), Total Lead Content  Test Method:  ASTM F963‐17 Clause 8.3.1 Analytical Method:  Inductively Coupled Plasma‐Optical Emission Spectrometry

 

Specimen No. 259+260 +261 

262+263 264+265+266 

267+268+269 

278   

Test Item Result (mg/kg) 

Result(mg/kg) 

Result(mg/kg) 

Result(mg/kg) 

Result (mg/kg) 

Limit(mg/kg) 

Total Lead (Pb)  ND  ND  ND  ND  ND  90 

Conclusion  PASS  PASS PASS PASS PASS   

 

Specimen No.  290  291 334+335 +336 

‐‐‐  ‐‐‐   

Test Item Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Result (mg/kg) 

Limit (mg/kg) 

Total Lead (Pb)  ND  ND  ND  ‐‐‐  ‐‐‐  90 

Conclusion  PASS  PASS PASS ‐‐‐ ‐‐‐   

 Note: mg/kg (Milligrams per kilogram) = ppm (Parts per million) = 0.0001 % m/m (Percent by mass) LT = Less than ND = Not detected (Reporting Limit = 20 ppm) Composite results are based on specimen of least mass resulting in highest potential concentration.     

Page 129: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 129 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION: 

 

Specimen No.  Specimen Description  Location 

1  Transparent black plastic (AS) Lid (1624‐31BK style); straw (1623‐49BK style); lid (all 1626‐13/ all 1625‐99/ all 1625‐76 styles) 

2  Transparent plastic (AS) 

Inner wall (all 1624‐31/ all 1623‐94/ 1623‐65CL/ 1623‐57CL/ 1624‐49CL styles); lid (all 1623‐82/ 1623‐65CL/ 1623‐57CL/ 1624‐49CL styles); infuser (all 1623‐82 styles); ring of straw (all 1623‐49 styles); spout (all 1624‐47 styles); lid (SM‐6440BK style); lid/ body (SM‐6670CL/ SM‐6620CL/ SM‐6868CL styles); lid/ inner wall (SM‐6657CL/ 1625‐17CL styles); body (all SM‐6659 styles); lid/ inner wall/ swivel (1625‐12MT style); lid (all 1625‐24 styles); lid (all 1626‐50 styles); inner wall (all 1626‐61/ all 1624‐87/ 1622‐98CL/ 1624‐69CL styles); lid (1626‐61CL/ 1622‐98CL/ all 1625‐53/ all 1625‐91/ 1624‐69CL styles); spout (all 1625‐18 styles) 

3  Transparent red plastic (AS) Lid (1624‐31RD/ 1625‐29RD/ 1626‐61RD/ 1624‐87RD styles) 

4  Translucent plastic (PP‐co) 

Ring of straw (all 1624‐31/ all 1623‐94/ 1624‐15SGL/ all 1623‐65/ 1624‐33SGL/ all SM‐6657/ all SM‐6670/ all SM‐6620/ all SM‐6659/ all SM‐6868/ all 1625‐17/ 1625‐12MT/ all 1624‐87/ all 1624‐69 styles); straw (1623‐94WH/ 1623‐65CL/ 1623‐57CL/ all 1624‐47/ 1624‐49CL/ SM‐6670CL/ SM‐6620CL/ SM‐6657CL/ SM‐6659WH/ SM‐6868CL/ 1625‐17CL/ 1625‐12MT/ all 1625‐29/ 1624‐69CL styles) 

    

Page 130: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 130 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

5  Black plastic (PP‐co) 

Lid (1623‐91BK/ all 1624‐51 styles); inner lid (all 1624‐74 styles); lid/ slider (all SM‐6840/ all SM‐6683 styles); body (all SM‐6683 styles); lid/ inner wall (all SM‐6675/ SM‐6925YL styles); lid (1624‐94IR style); inner lid (all 1625‐13/ 1625‐11WD/ 1625‐14WH styles); slider (all 1625‐17 styles); lid (1626‐58BK/ 1626‐58SL/ all 1625‐19 styles); inner lid (all 1626‐12/ all 1626‐11/ all 1625‐27/ all 1625‐26/ all 1625‐96/ all 1625‐65 styles); lid (all 1626‐01/ all 1625‐18 styles); lid/ slider (1625‐37SL style); neck of body (all 1625‐32 styles) 

6  Transparent blue plastic (AS) 

Lid (1624‐31BL/ 1623‐65BL/ 1623‐57BL/ 1623‐49BL styles); inner wall (1623‐65BL/ 1623‐57BL/ 1623‐49BL styles); lid/ inner wall (SM‐6657TRBL style); lid/ body (SM‐6670BL/ SM‐6620TRBL/ SM‐6868BL styles); lid/ inner wall (1625‐17RYL style); lid (1625‐29BL style); lid (1626‐61BL/ 1624‐87RYL style) 

7  Transparent dark black plastic (AS) 

Lid/ inner wall (1623‐65BK/ 1623‐57BK/ 1623‐49BK/ 1624‐49BK styles); lid (SM‐6440SL styles); lid/ body (SM‐6670BK/ SM‐6868BK style); lid/ inner wall (SM‐6657BK/ 1624‐69BK styles); lid (1625‐29BK style); lid (all 1625‐48/ all 1625‐69 styles); lid/ outer wall (1626‐61BK style) 

8  Transparent green plastic (AS) Lid/ inner wall (1623‐65GR/ 1623‐57GR styles); lid/ inner wall (SM‐6657GR style); lid (1625‐29LM style) 

9  Transparent orange plastic (AS) Lid/ inner wall (1623‐65OR/ 1623‐57OR styles) 

10  Transparent dark red plastic (AS) Lid/ inner wall (1623‐65RD/ 1623‐57RD/ 1624‐49RD styles); lid/ body (SM‐6670RE style); lid (SM‐6856RD style) 

11  Transparent bright blue plastic (AS)  Straw (1623‐49BL style) 

Page 131: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 131 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION: 

 

Specimen No.  Specimen Description  Location 

12  Translucent dark black plastic (PP‐co)  Straw (1624‐31BK style) 

13  Translucent blue plastic (PP‐co) 

Straw (1624‐31BL/ 1623‐94BL/ 1623‐65BL/ 1623‐57BL/ SM‐6657TRBL/ SM‐6670BL/ SM‐6620TRBL/ SM‐6659BL/ SM‐6868BL/ 1625‐17RYL/ 1624‐87RYL/ 1624‐69BL styles) 

14  Translucent red plastic (PP‐co) Straw (1624‐31RD/ 1623‐65RD/ 1623‐57RD/ 1624‐49RD/ SM‐6670RE/ SM‐6659RE/ 1624‐87RD styles) 

15  Translucent light turquoise plastic (PP‐co)  Straw (1624‐15SGL/ 1624‐33SGL styles) 

16  Translucent turquoise plastic (PP‐co)  Straw (1623‐94TQ style) 

17  Translucent black plastic (PP‐co) Straw (1623‐65BK/ 1623‐57BK/ 1624‐49BK/ SM‐6670BK/ SM‐6657BK/ SM‐6868BK/ 1624‐69BK styles) 

18  Translucent green plastic (PP‐co) Straw (1623‐65GR/ 1623‐57GR/ 1624‐49LM/ SM‐6657GR styles) 

19  Translucent orange plastic (PP‐co)  Straw (1623‐65OR/ 1623‐57OR styles) 

20  Grey plastic (PP‐co)  Slider (all 1623‐91 styles) 

21  Blue plastic (PP‐co)  Lid (1623‐91BL style) 

22  Red plastic (PP‐co)  Lid (1623‐91RD style) 

23  Dull blue plastic (PP‐co)  Lid (1623‐94BL style) 

24  Turquoise plastic (PP‐co) Lid (1623‐94TQ style); holder of infuser (1623‐82TQ style) 

25  Dull white plastic (PP‐co) Lid (1623‐94WH/ 1622‐84WH styles); body (1622‐84WH style); inner wall (all SM‐6588 styles); lid (SM‐6659WH style) 

26  Matt blue plastic (PP‐co)  Holder of infuser (1623‐82BL style) 

27  Green plastic (PP‐co)  Holder of infuser (1623‐82GR style) 

28  Bright grey plastic (PP‐co)  Holder of infuser (1623‐82GY style) 

29  Shiny red plastic (PP‐co) Holder of infuser (1623‐82RD style); lid (SM‐6659RE style) 

30  Dull grey plastic (PP‐co)  Swivel (1623‐49BK style) 

31  Off blue plastic (PP‐co)  Swivel (1623‐49BL style) 

Page 132: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 132 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION: 

 

Specimen No.  Specimen Description  Location 

32  Transparent turquoise plastic (Tritan)  Body (1624‐15SGL style) 

33  White plastic (Tritan)  Inner wall (all 1623‐91 styles) 

34  Clear plastic (Tritan) Body (all 1623‐82/ 1624‐47CL/ all SM‐6856 styles); lid/ body (SM‐6854CL style); straw (all 1626‐50 styles) 

35  Clear black plastic (ABS) 

Slider (1623‐65BK/ 1624‐49BK styles); spout (1623‐57BK style); slider (SM‐6657BK/ all 1625‐69/ 1624‐69BK styles); spout (1625‐29BK style); lid (all 1625‐48 styles); swivel (all 1625‐99 styles) 

36  Clear blue plastic (ABS) 

Slider (1623‐65BL style); spout (1623‐57BL style); slider (SM‐6657TRBL style); spout (1625‐29BL style); slider (1624‐87RYL style) 

37  Dull clear plastic (ABS) 

Slider (1623‐65CL style); spout (1623‐57CL/ 1624‐49CL styles); slider (SM‐6657CL style); slider (all 1626‐50/ 1624‐69CL styles) 

38  Clear green plastic (ABS) Slider (1623‐65GR style); spout (1623‐57GR style); slider (SM‐6657GR style); spout (1625‐29LM style) 

39  Clear orange plastic (ABS) Slider (1623‐65OR style); spout (1623‐57OR style) 

40  Clear red plastic (ABS) Slider (1623‐65RD style); spout (1623‐57RD/ 1624‐49RD/ 1625‐29RD styles); slider (1624‐87RD style) 

41  Transparent black plastic Lid/ bottom (1624‐31BK style); straw (1623‐49BK style); lid (all 1626‐13/ all 1625‐99/ all 1625‐76 styles) 

   

Page 133: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 133 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

42  Transparent plastic 

Inner wall (all 1624‐31/ all 1623‐94/ 1623‐65CL/ 1623‐57CL/ 1624‐49CL styles); handle (all 1624‐31 styles); lid (all 1623‐82/ 1623‐65CL/ 1623‐57CL/ 1624‐49CL styles); outer wall (all 1624‐31/ all 1623‐94/ all 1623‐65/ all 1623‐57/ all 1623‐49 styles); infuser (all 1623‐82 style); ring of straw (all 1623‐49 styles); spout (all 1624‐47 styles); outer wall (all 1624‐49 styles); lid (SM‐6440BK style); outer wall (all SM‐6657 styles); lid/ body (SM‐6670CL/ SM‐6620CL/ SM‐6868CL styles); lid/ inner wall (SM‐6657CL style); body (all SM‐6659 styles); outer wall (all 1625‐17 styles); lid/ inner wall (1625‐17CL style); lid/ swivel/ inner wall/ outer wall (1625‐12MT/ all 1624‐87 style); lid (all 1625‐24/ all 1625‐53/ all 1626‐50 styles); inner wall (all 1626‐61/ 1622‐98CL styles); lid/ outer wall (1626‐61CL/ 1622‐98CL/ all 1625‐91 styles); spout (all 1625‐18 styles); outer wall (all 1624‐69 styles) 

43  Transparent blue plastic 

Lid (1624‐31BL/ 1623‐65BL/ 1623‐57BL/ 1623‐49BL styles); inner wall (1623‐65BL/ 1623‐57BL/ 1623‐49BL styles); bottom (1624‐31BL style); lid/ inner wall (SM‐6657TRBL style); lid/ body (SM‐6670BL/ SM‐6620TRBL/ SM‐6868BL styles); lid/ inner wall (1625‐17RYL style); lid (1625‐29BL style); lid/ outer wall (1626‐61BL style); lid/ bottom (1624‐87RYL style) 

44  Transparent red plastic Lid/ bottom (1624‐31RD style); lid/ outer wall (1626‐61RD style); lid/ bottom (1624‐87RD style) 

    

Page 134: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 134 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

45  Black plastic 

Lid (1623‐91BK/ all 1624‐51 styles); flip (1623‐57BK/ all 1624‐51/ 1624‐49BK styles); inner lid (all 1624‐74 styles); lid/ slider (all SM‐6840/ all SM‐6683 styles); outer wall (SM‐6588BK style); body (all SM‐6683 styles); lid/ inner wall/ bottom (all SM‐6675 styles); lid/ inner wall (SM‐6925YL style); lid/ flip of lid (1624‐94IR style); inner lid (all 1625‐13/ 1625‐11WD/ 1625‐14WH styles); slider (all 1625‐17 styles); flip of lid (1625‐29BK style); handle (1625‐48BK/ 1625‐48SL styles); lid/ handle/ bottom (1626‐58BK/ 1626‐58SL styles); inner lid (all 1626‐12/ all 1626‐11/ all 1625‐27/ all 1625‐26/ all 1625‐96/ all 1625‐65 styles); lid (all 1626‐01/ all 1625‐18 styles); lid/ slider/ bottom (1625‐37SL style); neck of body (all 1625‐32 styles); lid/ handle (all 1625‐19 styles); bottom (1625‐69BK style) 

46  Translucent plastic 

Ring of straw (all 1624‐31/ all 1623‐94/ 1624‐15SGL/ all 1623‐65/ 1624‐33SGL/ all SM‐6657/ all SM‐6670/ all SM‐6620/ all SM‐6659/ all SM‐6868/ all 1625‐17/ 1625‐12MT/ all 1624‐87/ all 1624‐69 styles); straw (1623‐94WH/ 1623‐65CL/ 1623‐57CL/ 1624‐47/ all 1624‐47/ 1624‐49CL/ SM‐6670CL/ SM‐6620CL/ SM‐6657CL/ SM‐6659WH/ SM‐6868CL/ 1625‐17CL/ 1625‐12MT/ all 1625‐29/ 1624‐69CL styles); flip (1623‐57CL/ 1624‐49CL styles) 

47  Shiny blue plastic  Top/ bottom of body (1623‐94BL style) 

48  Bright turquoise plastic  Top/ bottom of body (1623‐94TQ style) 

49  Bright white plastic  Top/ bottom of body (1623‐94WH style) 

50  Bright black plastic  Outer wall (1623‐91BK style) 

51  Bright blue plastic  Outer wall (1623‐91BL style) 

Page 135: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 135 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

  SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

52  Bright red plastic  Outer wall (1623‐91RD style) 

53  Navy plastic  Flip (1623‐57BL style) 

54  Dull green plastic   Flip (1623‐57GR/ 1625‐29LM styles) 

55  Orange plastic   Flip (1623‐57OR style) 

56  Dull red plastic  Flip (1623‐57RD/ 1624‐49RD/ 1625‐29RD styles) 

57  Translucent soft plastic (Silicon) 

Gasket (all 1624‐31/ 1624‐15SGL/ all 1623‐91/ all 1623‐94/ all 1623‐82/ 1622‐84WH/ all 1623‐65/ all 1623‐57/ all 1623‐49/ all 1624‐74/ 1624‐60SGL/ all 1624‐51/ 1624‐33SGL/ all 1624‐47/ all 1624‐49/ SM‐6440BK/ all SM‐6657/ all SM‐6840/ SM‐6440SL/ all SM‐6670/ all SM‐6856/all SM‐6683/ all SM‐6675/ all SM‐6659/ all SM‐6868/ all SM‐6854/ 1624‐82BL/ all 1625‐13/ all 1625‐17/ 1625‐11WD/ 1625‐12MT/ 1625‐14WH/ all 1625‐24/ all 1625‐29/ all 1625‐48/ all 1626‐13/ all 1626‐50/ all 1626‐58/ all 1626‐61/ all 1626‐12/ all 1626‐11/ all 1626‐01/ all 1625‐99/ all 1625‐27/ all 1625‐26/ all 1625‐19/ all 1625‐18/ all 1624‐87/ 1622‐98CL/ 9870‐11CR/ all 1625‐96/ all 1625‐69/ all 1625‐65/ all 1625‐53/ all 1625‐91/ all 1624‐69 styles) 

58  Black soft plastic (TPR) Gasket of flip (1623‐57BK/ 1624‐49BK styles) 

59  Navy soft plastic (TPR)  Gasket of flip (1623‐57BL style) 

60  Green soft plastic (TPR)  Gasket of flip (1623‐57GR style) 

61  Orange soft plastic (TPR)  Gasket of flip (1623‐57OR style) 

62  Red soft plastic (TPR) Gasket of flip (1623‐57RD/ 1624‐49RD styles) 

63  Dull translucent soft plastic (TPR) Gasket of flip (1623‐57CL/ 1624‐49CL styles) 

   

Page 136: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 136 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

64  Translucent soft plastic (Silicon)  Gasket (all 1624‐31 styles) 

65  Translucent soft plastic (Silicon)  Gasket (1624‐15SGL style) 

66  Translucent soft plastic (Silicon)  Gasket (all 1623‐91 styles) 

67  Translucent soft plastic (Silicon)  Gasket (all 1623‐94 styles) 

68  Translucent soft plastic (Silicon)  Gasket (all 1623‐82 styles) 

69  Translucent soft plastic (Silicon)  Gasket (1622‐84WH style) 

70  Translucent soft plastic (Silicon)  Gasket (all 1623‐65 styles) 

71  Translucent soft plastic (Silicon) Gasket of lid (all 1623‐57/ all 1624‐49 styles) 

72  Translucent soft plastic (Silicon)  Gasket (all 1623‐49 styles) 

73  Silvery metal (#304 Stainless Steel) 

Lid (1624‐15SGL/ 1624‐33SGL styles); inner wall (all 1624‐74/ 1624‐60SGL/ all 1624‐51/ 1624‐88SL/ 1624‐94IR/ all 1625‐13/ 1625‐11WD/ 1625‐14WH/ all 1625‐24/ all 1625‐29/ all 1625‐48 styles); inner wall (all 1626‐13/ all 1626‐50/ all 1626‐58/ all 1626‐12/ all 1626‐11/ all 1626‐01/ all 1625‐99/ 1625‐37SL/ all 1625‐32/ all 1625‐27/ all 1625‐26/ all 1625‐19/ 1624‐39SL/ 9870‐11CR/ all 1625‐96/ all 1625‐76/ all 1625‐69/ all 1625‐65/ all 1625‐53 styles) 

    

Page 137: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 137 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

74  Silvery metal 

Lid (1624‐15SGL/ 1624‐33SGL styles); outer wall/ bottom (all 1624‐74 styles); outer lid (all 1624‐74/ 1624‐60SGL styles); inner wall (all 1624‐74/ 1624‐60SGL/ all 1624‐51/ 1624‐94IR/ 1624‐39SL styles); inner wall/ outer wall/ handle (1624‐88SL style); outer lid/ inner wall/ outer wall/ bottom (all 1625‐13/ 1625‐11WD/ 1625‐14WH styles); outer wall (all 1625‐24/ all 1625‐29 styles); opener (all 1625‐24 styles); inner wall/ outer wall (all 1625‐48 styles); inner wall/ outer wall (all 1626‐13/ all 1626‐50/ all 1626‐58/ all 1626‐12/ all 1626‐11/ all 1626‐01/ all 1625‐99/ 1625‐37SL/ all 1625‐32/ all 1625‐27/ all 1625‐26/ all 1625‐19/ 9870‐11CR/ all 1625‐96/ all 1625‐76/ all 1625‐69/ all 1625‐65/ all 1625‐53 styles); outer lid/ bottom (all 1626‐12/ all 1626‐11/ all 1625‐27/ all 1625‐26/ 9870‐11CR/ all 1625‐96/ all 1625‐65 styles) 

76  Dull silvery metal  

Outer wall (all 1624‐51/ SM‐6440BK styles); outer wall (all SM‐6840/ SM‐6440SL/ all SM‐6675/ 1624‐82BL styles); inner wall (all 1625‐18 styles) 

77  Coppery coating On outer wall/ bottom (1624‐74RGD/ 1624‐51RGD/ 1625‐13RGD styles); outer lid (1624‐74RGD/ 1625‐13RGD styles) 

78  Bright green coating On outer wall/ outer lid/ bottom (1624‐74NGR style) 

79  Pink coating On outer wall/ outer lid/ bottom (1624‐74NPK style) 

80  Orange coating On outer wall/ outer lid/ bottom (1624‐74NOR style) 

81  Blue coating On outer wall/ outer lid/ bottom (1624‐74NEBL style) 

    

Page 138: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 138 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

82  Dark red coating On outer wall/ outer lid/ bottom (1624‐74RD style) 

84  Green coating On outer wall/ outer lid/ bottom (1624‐74LM style) 

85  Dark green coating On outer wall/ outer lid/ bottom (1624‐74GR style) 

89  Black coating  

On outer wall/ outer lid/ bottom (1625‐13BK styles); outer wall (SM‐6440BK/ 1625‐48BK/ 1626‐13BK/ 1626‐58BK/ 1626‐12BK/ 1626‐01BK/ 1625‐27BK/ 1625‐19BK/ 1625‐96BK/ 1625‐69BK styles) 

92  Clear turquoise plastic (AS) Lid/ neck of body (1624‐60SGL style); inner wall (1624‐33SGL style) 

93  Shiny grey plastic (PP‐co)  Lid (all 1624‐47 styles) 

94  Translucent purple plastic (PP‐co)  Straw (1624‐49PP style) 

95  Translucent light blue plastic (PP‐co)  Straw (1624‐49BL style) 

96  Dull transparent black plastic (Tritan) Body (1624‐47BK style); lid/ body (SM‐6854SM style) 

97  Dull transparent blue plastic (Tritan)  Body (1624‐47BL style) 

98  Dull transparent green plastic (Tritan)   Body (1624‐47LM style) 

99  Dull transparent orange plastic (Tritan)  Body (1624‐47OR style) 

100  Transparent purple plastic (Tritan)  Body (1624‐47PP style) 

101  Dull transparent red plastic (Tritan)  Body (1624‐47RD style) 

102  Clear purple plastic (AS)  Lid/ inner wall ( 1624‐49PP style) 

103  Clear bright green plastic (AS) Lid/ inner wall (1624‐49LM style); lid/ body (SM‐6620TLGR style) 

104  Clear bright blue plastic (AS) Lid/ inner wall (1624‐49BL/ 1624‐69BL styles) 

    

Page 139: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 139 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

105  Dull clear purple plastic (ABS)  Spout (1624‐49PP style) 

106  Clear shiny green plastic (ABS)  Spout (1624‐49LM style) 

107  Clear shiny blue plastic (ABS)  Spout (1624‐49BL style) 

108  Clear turquoise plastic Lid/ neck of body/ outer wall/ bottom (1624‐60SGL style); inner wall/ outer wall/ handle (1624‐33SGL style) 

109  Shiny grey plastic Lid/ handle/ wrapper of body (all 1624‐47 styles) 

110  Purple plastic   Flip of lid (1624‐49PP style) 

111  Bright green plastic   Flip of lid (1624‐49LM style) 

112  Sharp blue plastic  Flip of lid (1624‐49BL style) 

113  Grey soft plastic   Patch on lid/ handle (1624‐47BK style) 

114  Blue soft plastic   Patch on lid/ handle (1624‐47BL style) 

115  White soft plastic   Patch on lid/ handle (1624‐47CL style) 

116  Bright green soft plastic  Patch on lid/ handle (1624‐47LM style) 

117  Bright orange soft plastic   Patch on lid/ handle (1624‐47OR style) 

118  Purple soft plastic   Patch on lid/ handle (1624‐47PP style) 

119  Dull red soft plastic   Patch on lid/ handle (1624‐47RD style) 

120  Translucent soft plastic  Pad of bottom (1624‐60SGL style) 

121  Black soft plastic (TPR)  Gasket of flip (all 1624‐51 style) 

122  Shiny green soft plastic (TPR)  Gasket of flip (1624‐49LM style) 

    

Page 140: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 140 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

123  Dull purple soft plastic (TPR)  Gasket of flip (1624‐49PP style) 

124  Dull blue soft plastic (TPR)  Gasket of flip (1624‐49BL style) 

125  Translucent soft plastic (Silicone) Gasket (all 1624‐74/ 1625‐11WD/ 1625‐14WH styles) 

126  Translucent soft plastic (Silicone)  Gasket (1624‐60SGL style) 

127  Translucent soft plastic (Silicone)  Gasket (all 1624‐51 style) 

128  Translucent soft plastic (Silicone)  Gasket (1624‐33SGL style) 

129  Translucent soft plastic (Silicone)  Gasket (all 1624‐47 styles) 

135  Black printed dull silvery metal  Lip & Rim of tumbler (SM‐6440BK style) 

136  Shiny black plastic (AS) Inner wall (SM‐6440BK/ all SM‐6840/ SM‐6440SL/ 1625‐91BK styles) 

137  Black foam with adhesive Pad of bottom (SM‐6440BK/ all SM‐6840/ SM‐6440SL/ 1624‐82BL styles) 

138  Translucent soft plastic (Silicone)  Gasket (SM‐6440BK/ SM‐6440SL styles) 

139  Deep red coating  On outer wall (SM‐6840RD style) 

140  Deep grey coating  On outer wall (SM‐6840BK style) 

141  Shiny green coating  On outer wall (SM‐6840GR style) 

142  Bright blue coating  On outer wall (SM‐6840YL style) 

143  Silvery coating  On outer wall (SM‐6840SL style) 

144  Red coating   On outer wall (SM‐6675RE style) 

145  Dull blue coating  On outer wall (SM‐6675BL style) 

146  Rare blue plastic (PP‐co)  Lid (SM‐6659BL style) 

147  Dull translucent green plastic (PP‐co)  Straw (SM‐6620TLGR style) 

148  Dull clear green plastic (AS)  Lid (SM‐6856GR style) 

149  Shiny white plastic (AS)  Upper body (all SM‐6854 styles) 

150  Dull black plastic (ABS) Slider (all SM‐6675/ 1625‐91BK styles); lid/ handle (all 1625‐32 styles) 

151  Dull clear blue plastic (Tritan)  Lid/ body (SM‐6854BL style) 

152  Dull matt blue plastic  Flip/ outer wall (SM‐6925YL/ 1625‐29BL styles) 

Page 141: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 141 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

153  Shine blue plastic   Outer wall (SM‐6588BL style) 

154  Bright navy plastic   Outer wall (SM‐6588NY style) 

155  Shine red plastic  Outer wall (SM‐6588RD style) 

156  Dull clear red plastic  Bottom (SM‐6856RD style) 

157  Matt clear green plastic   Bottom (SM‐6856GR style) 

158  Matt red soft plastic  String of lid (SM‐6856RD style) 

159  Dull green soft plastic  String of lid (SM‐6856GR style) 

160  Bright blue soft plastic  Sleeve of body (SM‐6683PBL style) 

161  Matt green soft plastic   Sleeve of body (SM‐6683LM style) 

162  Dark blue soft plastic (TPR)  Gasket of flip (SM‐6925YL style) 

163  Dull black soft plastic (Silicone)  Gasket of lid (SM‐6925YL style) 

164  Translucent soft plastic (Silicon)  Gasket (all SM‐6657 styles) 

165  Translucent soft plastic (Silicon)  Gasket (all SM‐6840 styles) 

166  Translucent soft plastic (Silicon)  Gasket (all SM‐6670 styles) 

167  Translucent soft plastic (Silicon)  Gasket (all SM‐6856 styles) 

168  Translucent soft plastic (Silicon)  Gasket (all SM‐6683 styles) 

169  Translucent soft plastic (Silicon)  Gasket (all SM‐6675 styles) 

170  Translucent soft plastic (Silicon)  Gasket (all SM‐6659 styles) 

171  Translucent soft plastic (Silicon)  Gasket (all SM‐6868 styles) 

172  Translucent soft plastic (Silicon)  Gasket (all SM‐6854 styles) 

173  Deep red printed dull silvery metal Lip and Rim of tumbler (SM‐6840RD style) 

174  Deep grey printed dull silvery metal Lip and Rim of tumbler (SM‐6840BK style) 

175  Shiny green printed dull silvery metal Lip and Rim of tumbler ( SM‐6840GR style) 

176  Bright blue printed dull silvery metal Lip and Rim of tumbler (SM‐6840YL style) 

177  Silvery printed dull silvery metal Lip and Rim of tumbler (SM‐6840SL style) 

Page 142: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 142 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

178  Shiny blue coating  On outer wall (1624‐82BL style) 

179  Dull navy coating  On outer wall (1625‐13NY/ 1625‐48NY/ 1626‐58NY/ 1626‐01NY/ 1625‐96NY/ 1625‐69NY/ 1626‐13NY styles) 

180  Golden coating  On outer lid/ bottom (1625‐14WH style) 

181  Dull black coating On outer wall (1625‐24BK/ 1626‐50BK/ 1625‐76BK/ 1625‐65BK/ 1625‐53BK styles); handle (1625‐76BK style) 

182  Dull green coating  On outer wall (1625‐24LM style) 

183  Matt blue coating  On outer wall (1625‐24NY style) 

184  Dull white coating  On outer wall (1625‐24WH style) 

185  Bright black coating  On outer wall (1625‐29BK style) 

186  Shiny grey coating On outer wall/ outer lid/ bottom (1624‐74TI/ 1625‐13TI styles) 

187  Dull grey coating On outer wall (1625‐48GY/ 1626‐58GY/ 1626‐01GY/ 1625‐69GY styles) 

188  Bright red coating  On outer wall (1625‐29RD style) 

189  Shine green coating  On outer wall (1625‐29LM style) 

190  Multicolor coating On outer wall/ bottom (1625‐11WD style) 

191  Multicolor coating  On outer (1625‐14WH style) 

192  Matt dull blue plastic (AS)  Inner wall (1624‐82BL style) 

193  Shine grey plastic (PP‐co)  Lid (1624‐82BL style) 

194  Dull off blue plastic (PP‐co)  Swivel of lid (1624‐82BL style) 

195  Dull matt black plastic (Tritan)  Lid (1624‐88SL style) 

196  Dark blue plastic   Handle (1625‐48NY style) 

197  Matt grey plastic   Handle (1625‐48GY style) 

198  Brown soft plastic  Inner handle (all 1625‐48 styles); inner handle/ bottom (all 1626‐58 styles); bottom (all 1625‐69 styles) 

199  Translucent soft plastic (Silicon)  Gasket (1624‐82BL style) 

Page 143: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 143 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

200  Dull black soft plastic (Silicon)  Gasket (1624‐88SL style) 

201  Black soft plastic (TPR)  Gasket of flip (1624‐94IR style) 

202  Dull black soft plastic (Silicon)  Gasket (1624‐94IR style) 

203  Translucent soft plastic (Silicon)  Gasket (all 1625‐13 styles) 

204  Translucent soft plastic (Silicon)  Gasket (all 1625‐17 styles) 

205  Translucent soft plastic (Silicon)  Gasket (1625‐12MT style) 

206  Translucent soft plastic  Gasket (all 1625‐24 styles) 

207  Translucent soft plastic (Silicon)  Gasket (all 1625‐29 styles) 

208  Black soft plastic (TPR)  Gasket of flip (1625‐29BK style) 

209  Translucent soft plastic (Silicone)  Gasket (all 1625‐48 styles) 

210  Red soft plastic (TPR)  Gasket of flip (1625‐29RD style) 

211  Dull blue soft plastic (TPR)  Gasket of flip (1625‐29BL style) 

212  Off green soft plastic (TPR)  Gasket of flip (1625‐29LM style) 

213  Multicolor plated silvery metal  Outer wall (1624‐94IR style) 

214  Shiny blue printed dull silvery metal  Lip & Rim of tumbler (1624‐82BL style) 

215  Dull black printed silvery metal  Lip & Rim of tumbler (1625‐24BK style) 

216  Dull green printed silvery metal  Lip & Rim of tumbler (1625‐24LM style) 

217  Matt blue printed silvery metal  Lip & Rim of tumbler (1625‐24NY style) 

218  Dull white printed silvery metal  Lip & Rim of tumbler (1625‐24WH style) 

219  Black printed silvery metal  Lip & Rim of tumbler (1625‐48BK style) 

220  Dull grey printed silvery metal  Lip & Rim of tumbler (1625‐48GY style) 

221  Dull navy printed silvery metal  Lip & Rim of tumbler (1625‐48NY style) 

222  Sharp grey coating On outer wall (1626‐13GM/ 1626‐12GM/ 1626‐01GM/ 1625‐27GY styles) 

223  Matt white coating On outer wall (1626‐13WH/ 1625‐27WH/ 1625‐96WH/ 1625‐69WH styles) 

224  Matt grey coating Outer wall (1626‐50GY/ 1625‐76GY/ 1625‐65GY/ 1625‐53GY styles); handle (1625‐76GY style) 

Page 144: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 144 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

225  Turquoise coating On outer wall (1626‐50MTGR/ 1625‐53MTGR styles) 

226  Matt navy coating On outer wall (1626‐50NY/ 1625‐76NY/ 1625‐65NY/ 1625‐53NY styles); handle (1625‐76NY style) 

227  Dark orange coating  On outer wall (1626‐50OR style) 

228  Sharp blue coating On outer wall (1626‐50PBL/ 1625‐53PBL styles) 

229  Dull red coating On outer wall (1626‐50RD/ 1625‐53RD styles) 

230  Off white coating On outer wall (1626‐50WH/ 1625‐76WH/ 1625‐65WH/ 1625‐53WH styles); handle (1625‐76WH style) 

231  Flat white coating On outer wall (1626‐58WH/ 1626‐01WH styles) 

232  Black/ white inseparable coating  On outer wall (1626‐11BK style) 

233  Green/ white inseparable coating  On outer wall (1626‐11HG style) 

234  Blue/ white inseparable coating  On outer wall (1626‐11NY style) 

235  Multicolor coating  On outer wall (1626‐11WH style) 

236  Sharp black coating  On outer wall (1625‐99BK style) 

237  Shine blue coating  On outer wall (1625‐99BL style) 

238  Bright navy coating  On outer wall (1625‐99MDBL style) 

239  Shine grey coating  On outer wall (1625‐99TI style) 

240  Bright white coating  On outer wall (1625‐99WH style) 

241  Rare white coating  On inner wall (all 1625‐32 styles) 

242  Deep blue coating  On outer wall (1625‐32BL style) 

243  Rare blue coating  On outer wall (1625‐27RYL style) 

244  Soft blue coating  On outer wall (1625‐26IRBL style) 

245  Purple coating  On outer wall (1625‐26IRGD style) 

246  Sharp green coating  On outer wall (1625‐26IRGR style) 

   

Page 145: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 145 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

247  Shiny white coating  On outer wall (1625‐26IRWH style) 

248  Dull matt blue coating On outer wall (1625‐19BL/ 1625‐18BL styles) 

249  Transparent coating  On outer wall (1625‐19SL style) 

250  Matt green coating  On outer wall (1625‐19LM style) 

251  Off grey coating  On outer wall (1625‐18GA style) 

252  Matt red coating  On outer wall (1625‐18RD style) 

253  Dark coppery coating  On outer lid/ bottom (9870‐11CR style) 

254  Beige coating  On outer wall (9870‐11CR style) 

255  Off grey plastic (PP‐co)  Lid (1626‐58GY style) 

256  Matt white plastic (PP‐co)  Lid (1626‐58WH style) 

257  Flat blue plastic (PP‐co)  Lid (1626‐58NY style) 

258  Off clear green plastic (AS)  Lid (1626‐61GR style) 

259  Dull translucent plastic (PE)  Straw (all 1625‐18 styles) 

260  Off grey plastic  Lid/ handle/ bottom (1626‐58GY style); bottom (1625‐69GY style) 

261  Matt white plastic  Lid/ handle/ bottom (1626‐58WH style); bottom (1625‐69WH style) 

262  Flat blue plastic  Lid/ handle/ bottom (1626‐58NY style); bottom (1625‐69NY style) 

263  Dark grey plastic (PP‐co)  Inner lid (9870‐11CR style) 

264  Sharp white plastic (AS)  Inner wall (1625‐91WH style) 

265  Flat off blue plastic (AS)  Inner wall (1625‐91BL style) 

266  Flat white plastic (ABS)  Slider (1625‐91WH style) 

267  Off flat blue plastic (ABS)  Slider (1625‐91BL style) 

268  Matt clear blue plastic (ABS)  Slider (1624‐69BL style) 

269  Off clear green plastic   Lid/ outer wall (1626‐61GR style) 

270  Sharp grey plastic   Moving part of handle (1625‐32SL style) 

271  Deep blue plastic   Moving part of handle (1625‐32BL style) 

Page 146: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 146 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

272  Sharp red plastic  Handle (1625‐18RD style) 

273  Light grey plastic  Handle (1625‐18SL style) 

274  Deep grey plastic  Handle (1625‐18GA style) 

275  Off dull blue plastic  Handle (1625‐18BL style) 

276  Multicolor printed off white plastic   Outer lid (all 1626‐01 styles) 

277  Black soft plastic  Ring of bottom (1625‐37SL style); ring of moving of handle (all 1625‐32 styles) 

278  Bright grey soft plastic (Silicone)  Gasket/ band of lid (1625‐32SL style) 

279  Deep blue soft plastic   Band of lid (1625‐32BL style) 

280  Dark grey soft plastic  Band of lid/ body (all 1625‐19 styles) 

281  Bright grey soft plastic (Silicone)  Gasket (all 1625‐32 styles) 

282  Translucent soft plastic (Silicone)  Gasket (all 1626‐13 styles) 

283  Translucent soft plastic (Silicone)  Gasket (all 1626‐50 styles) 

284  Translucent soft plastic (Silicone)   Gasket (all 1626‐58 styles) 

285  Translucent soft plastic (Silicone)  Gasket (all 1626‐61 styles) 

286  Translucent soft plastic (Silicone)  Gasket (all 1626‐12 styles) 

287  Translucent soft plastic (Silicone)  Gasket (all 1626‐11 styles) 

288  Translucent soft plastic (Silicone)  Gasket (all 1626‐01 styles) 

289  Translucent soft plastic (Silicone)  Gasket (all 1625‐99 styles) 

290  Dull black soft plastic (Silicone)  Gasket (1625‐37SL style) 

291  Dull black soft plastic (Silicone)  Gasket (all 1625‐76 styles) 

292  Translucent soft plastic (Silicone)  Gasket (all 1625‐27 styles) 

293  Translucent soft plastic (Silicone)  Gasket (all 1625‐26/ 9870‐11CR styles) 

294  Translucent soft plastic (Silicone)  Gasket (all 1625‐19 styles) 

295  Translucent soft plastic (Silicone)  Gasket (all 1625‐18 styles) 

296  Translucent soft plastic (Silicone)  Gasket (all 1624‐87 styles) 

297  Translucent soft plastic (Silicone)  Gasket (1622‐98CL style) 

Page 147: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 147 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

298  Translucent soft plastic (Silicone)  Gasket (all 1625‐96 styles) 

299  Translucent soft plastic (Silicone)  Gasket (all 1625‐69 styles) 

300  Translucent soft plastic (Silicone)  Gasket (all 1625‐65 styles) 

301  Translucent soft plastic (Silicone)  Gasket (all 1625‐53 styles) 

302  Translucent soft plastic (Silicone)  Gasket (all 1625‐91 styles) 

303  Translucent soft plastic (Silicone)  Gasket (all 1624‐69 styles) 

304  Matt silvery metal Axis of moving part of handle (all 1625‐32 styles) 

305  Bright silvery metal  Bottom (all 1625‐32 styles) 

306  Dull silvery metal  Inner wall (all 1625‐18 styles) 

307  Off silvery metal  Handle (all 1625‐76 styles) 

308  Black printed silvery metal  Lip & Rim of cup (1626‐13BK style) 

309  Sharp grey printed silvery metal  Lid & Rim of cup (1626‐13GM style) 

310  Dull navy printed silvery metal  Lip & Rim of cup (1626‐13NY style) 

311  Matt white printed silvery metal  Lip & Rim of cup (1626‐13WH style) 

312  Black printed silvery metal  Lip & Rim of bottle (1626‐01BK style) 

313  Sharp grey printed silvery metal  Lip & Rim of bottle (1626‐01GM style) 

314  Dull grey printed silvery metal  Lip & Rim of bottle (1626‐01GY style) 

315  Dull navy printed silvery metal  Lip & Rim of bottle (1626‐01NY style) 

316  Flat white printed silvery metal  Lip & Rim of bottle (1626‐01WH style) 

317  Sharp black printed silvery metal  Lip & Rim of tumbler (1625‐99BK style) 

318  Shine blue printed silvery metal  Lip & Rim of tumbler (1625‐99BL style) 

319  Bright navy printed silvery metal Lip & Rim of tumbler (1625‐99MDBL style) 

320  Shine grey printed silvery metal  Lip & Rim of tumbler (1625‐99TI style) 

321  Bright white printed silvery metal  Lip & Rim of tumbler (1625‐99WH style) 

322  Dull black printed silvery metal  Lip & Rim of mug (1625‐76BK style) 

323  Matt grey printed silvery metal  Lip & Rim of mug (1625‐76GY style) 

Page 148: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 148 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SPECIMEN DESCRIPTION:  

Specimen No.  Specimen Description  Location 

324  Matt navy printed silvery metal  Lip & Rim of mug (1625‐76NY style) 

325  Off white printed silvery metal  Lip & Rim of mug (1625‐76WH style) 

326  Black printed silvery metal  Lip & Rim of tumbler (1625‐69BK style) 

327  Dull grey printed silvery metal  Lip & Rim of tumbler (1625‐69GY style) 

328  Dull navy printed silvery metal  Lip & Rim of tumbler (1625‐69NY style) 

329  Matt white printed silvery metal  Lip & Rim of tumbler (1625‐69WH style) 

330  Dull black printed silvery metal  Lip & Rim of bottle (1625‐65BK style) 

331  Matt grey printed silvery metal  Lip & Rim of bottle (1625‐65GY style) 

332  Off white printed silvery metal  Lip & Rim of bottle (1625‐65WH style) 

333  Matt navy printed silvery metal  Lip & Rim of bottle (1625‐65NY style) 

334  Matt translucent plastic (PP‐homo) Straw (1625‐91WH style); ring of straw (all 1625‐91 styles) 

335  Dull translucent blue plastic (PP‐homo)  Straw (1625‐911BL style) 

336  Dull translucent black plastic (PP‐homo)  Straw (1625‐91BK style) 

    

Page 149: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 149 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SAMPLE PHOTO: 

 

  

    

Page 150: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 150 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SAMPLE PHOTO: 

 

  

   

   

Page 151: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 151 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SAMPLE PHOTO: 

 

  

    

Page 152: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 152 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SAMPLE PHOTO: 

 

  

    

Page 153: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 153 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SAMPLE PHOTO: 

 

  

    

Page 154: AT-1500 TEST REPORT · Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. The test result(s) and conclusion(s) in this report relate to the sample(s)

Test Report #: 18H‐009740      Page 154 of 154

QIMA Testing (HK) Limited  3/F Liven House, No. 61 – 63 King Yip Street, Kwun Tong, Kowloon, Hong Kong  Tel: (852)3185 8000. The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB) according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation. 

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of QIMA Testing (HK) Limited. 

ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. 

CS-HK-RE005-POLY Ver.12

In December 2018, ANSECO became QIMA. 

 SAMPLE PHOTO: 

 

  

‐End Report‐