atdm-0604 ip control protcol specifications · revision history date version revised points...

95
ATDM-0604 IP Control Protocol Specifications DIGITAL SMARTMIXER Version1.0.2

Upload: others

Post on 23-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

ATDM-0604

IP Control Protocol SpecificationsDIGITAL SMARTMIXER

Version1.0.2

Page 2: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

Revision History

Date Version Revised points

2018/04/27 Ver1.0.2 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level” parameters.

4.2.35, 4.2.36 Modified” Reference Level”parameters.

4.2.46 “Output Mute Setting Change Request” is added.

4.2.47 “Output Mute Setting Acquisition Request” is added.

5.2.9 “Output Mute Setting Notice” is added.

Page 3: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

Table of Contents

1 Preface............................................................................................................................................................1

1.1 Purpose of this document ...........................................................................................................................1

1.2 Definition of technical terms/Numerical value regulation ...........................................................................1

2 Basic Specification..........................................................................................................................................2

2.1 Transmission Interface ................................................................................................................................2

2.2 Command Protocol .....................................................................................................................................3

2.2.1 Common Command.............................................................................................................................3

2.2.2 Set Command/Get Command .............................................................................................................4

2.2.3 ACK ......................................................................................................................................................5

2.2.4 NAK ......................................................................................................................................................5

2.2.5 Answer .................................................................................................................................................6

2.2.6 Information ...........................................................................................................................................6

2.2.7 Request................................................................................................................................................7

3 Table of commands.........................................................................................................................................8

4 TCP communication ..................................................................................................................................... 11

4.1 Communication control ............................................................................................................................. 11

4.1.1 Start of communication ..................................................................................................................... 12

4.1.2 Control sequence.............................................................................................................................. 12

4.1.3 Communication error ........................................................................................................................ 14

4.1.4 End of communication ...................................................................................................................... 15

4.2 Command details ..................................................................................................................................... 16

4.2.1 Factory Default Setting Request ...................................................................................................... 17

4.2.2 Permission Setting Change Request ............................................................................................... 18

4.2.3 Permission Setting Acquisition Request ........................................................................................... 19

4.2.4 Network Setting Change Request .................................................................................................... 20

4.2.5 Network Setting Acquisition Request ............................................................................................... 21

4.2.6 Firmware Version Acquisition Request ............................................................................................. 22

4.2.7 Header Color Setting Change Request ............................................................................................ 23

4.2.8 Header Color Setting Acquisition Request ....................................................................................... 23

4.2.9 Audio-Technica LINK Mode Setting Change Request ..................................................................... 24

4.2.10 Audio-Technica LINK Mode Setting Acquisition Request ................................................................. 24

4.2.11 Connected Device Limit Setting Change Request ........................................................................... 25

4.2.12 Connected Device Limit Setting acquisition Request ...................................................................... 26

4.2.13 Audio System Setting Change Request ........................................................................................... 27

4.2.14 Audio System Setting Acquisition Request ...................................................................................... 28

4.2.15 Front Panel Restriction Setting Change Request ............................................................................ 29

4.2.16 Front Panel Restriction Setting Acquisition Request ........................................................................ 30

4.2.17 Input Gain&Level Setting Change Request ..................................................................................... 31

4.2.18 Input Gain&Level Setting Acquisition Request ................................................................................. 32

4.2.19 Output Level Setting Change Request ............................................................................................. 33

4.2.20 Output Level Setting Acquisition Request ........................................................................................ 34

Page 4: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

4.2.21 Input Channel Setting Change Request ........................................................................................... 35

4.2.22 Input Channel Setting Acquisition Request ...................................................................................... 36

4.2.23 Output Channel Setting Change Request ........................................................................................ 38

4.2.24 Output Channel Setting Acquisition Request ................................................................................... 39

4.2.25 Input EQ Setting Change Request ................................................................................................... 40

4.2.26 Input EQ Setting Acquisition Request .............................................................................................. 41

4.2.27 Output EQ Setting Change Request ................................................................................................ 42

4.2.28 Output EQ Setting Acquisition Request............................................................................................ 43

4.2.29 FBS Setting Change Request .......................................................................................................... 44

4.2.30 FBS Setting Acquisition Request ...................................................................................................... 45

4.2.31 FBS Common Setting Change Request........................................................................................... 46

4.2.32 FBS Common Setting Acquisition Request ...................................................................................... 47

4.2.33 Dynamics&Delay Setting Change Request ...................................................................................... 48

4.2.34 Dynamics&Delay Setting Acquisition Request ................................................................................. 49

4.2.35 AEC Setting Change Request .......................................................................................................... 50

4.2.36 AEC Setting Acquisition Request ..................................................................................................... 51

4.2.37 AEC Calibration Test Request .......................................................................................................... 52

4.2.38 AEC Calibration Start Request ......................................................................................................... 53

4.2.39 AEC Calibration Stop Request ......................................................................................................... 53

4.2.40 USB Out Setting Change Request ................................................................................................... 54

4.2.41 USB Out Setting Acquisition Request .............................................................................................. 55

4.2.42 Smart Mix Setting Change Request ................................................................................................. 56

4.2.43 Smart Mix Setting acquisition Request............................................................................................. 57

4.2.44 Smart Mix Common Setting Change Request ................................................................................. 58

4.2.45 Smart Mix Common Setting acquisition Request ............................................................................. 59

4.2.46 Output Mute Setting Change Request ............................................................................................. 60

4.2.47 Output Mute Setting Acquisition Request ......................................................................................... 61

4.2.48 Logging Setting Change Request .................................................................................................... 62

4.2.49 Logging Setting Acquisition Request ................................................................................................ 63

4.2.50 Web Remote Operator Page Common Setting Change Request ................................................... 64

4.2.51 Web Remote Operator Page Common Setting Acquisition Request ............................................... 65

4.2.52 Web Remote Operator Page Channel Setting Change Request ..................................................... 66

4.2.53 Web Remote Operator Page Channel Setting Acquisition Request ............................................. 67

4.2.54 Preset Load Request ........................................................................................................................ 69

4.2.55 Preset Save Request ........................................................................................................................ 69

4.2.56 Preset Name Change Request ........................................................................................................ 70

4.2.57 Preset Name Acquisition Request .................................................................................................... 71

4.2.58 Boot Up Preset Setting Change Request ......................................................................................... 72

4.2.59 Boot Up Preset Setting Acquisition Request .................................................................................... 72

4.2.60 File Transfer Request ....................................................................................................................... 73

4.2.61 File Transfer Cancelling Request ..................................................................................................... 74

4.2.62 Export Request ................................................................................................................................. 75

4.2.63 Import Request ................................................................................................................................. 76

Page 5: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

4.2.64 Level Meter Interval Change Request .............................................................................................. 76

4.2.65 Level Meter Acquisition Request ...................................................................................................... 77

4.2.66 Identify Request ................................................................................................................................ 78

4.2.67 Date Setting Request ....................................................................................................................... 79

4.2.68 Reboot Request ................................................................................................................................ 79

5 UDP communication .................................................................................................................................... 80

5.1 Communication control ............................................................................................................................ 80

5.1.1 Start of communication ..................................................................................................................... 80

5.1.2 Control sequence.............................................................................................................................. 80

5.1.3 Communication error ........................................................................................................................ 80

5.1.4 End of communication ...................................................................................................................... 80

5.2 Command details ..................................................................................................................................... 81

5.2.1 Level Meter Notice ............................................................................................................................ 81

5.2.2 Open Channel State Notice .............................................................................................................. 82

5.2.3 Can Cut Notice ................................................................................................................................. 83

5.2.4 Recall Preset Notice ......................................................................................................................... 83

5.2.5 Input Gain Level Setting Notice ........................................................................................................ 84

5.2.6 Output level Setting Notice ............................................................................................................... 84

5.2.7 FBS Notice ........................................................................................................................................ 85

5.2.8 Web Remote Operator Page Setting Notice .................................................................................... 85

5.2.9 Output Mute Setting Notice .............................................................................................................. 86

6 Appendix ...................................................................................................................................................... 87

6.1 Fader Table .............................................................................................................................................. 87

6.2 Frequency Table....................................................................................................................................... 88

6.3 Q Value Table ........................................................................................................................................... 89

6.4 EQ Gain Table .......................................................................................................................................... 89

6.5 Input Gain Table ....................................................................................................................................... 90

6.6 Transfer data kind .................................................................................................................................... 90

Page 6: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

1

1 Preface

This document refers to the command specification of the ATDM-0604 developed by audio-technica Limited.

The following table defines technical terms and numerical values, which are used in this document.

Technical Term Definition

Host Device, which outputs the control commands. Refers to application software and

control devices.

Device Device, which receives control commands.

AT Device Refers to devices developed by audio-technica.

Message A character string, which is embedded in a data format and sent and received with

one message.

Command A command to control a device. Embedded in a message.

Parameter Used in combination with commands. A setting value, which defines the operation

of a command.

<Numerical values>

Binary code・・・・Shown with a “b” after the character string. Example: 1010 0110b

Hexadecimal system・・・Shown with an “0x” before the character string. Example: 0xA6

Page 7: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

2

2 Basic Specification

The IP control function executes the operation of the ATDM-0604 through TCP or UDP protocol.

Table 2-1 Communication Interface

No Item Content Remarks

1. Communication type Full duplex

2. Transfer rate 10Mbps / 100Mbps

3. Port number TBD

4. Maximum data lentgh1 287byte (including “Carriage

Return”)

Ethernet header 32byte, Control

command 255byte

5. Connector type Device: RJ45 connector

(10/100Mbps suitable)

Cable: More than CAT5e

1 File Transfer Request and Export Request are exceptions.

Page 8: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

3

Transmitting and receiving commands are classified as follows.

Table 2-2 Communication Interface

No Command Content Remarks

1. Set Command Action Command Changes ATDM-0604 settings

2. Get Command Action Command ATDM-0604 setting; Status

acquisition

3. ACK Acknowledgment Response to “Set Command”

4. NAK Negative Acknowledgment Response to “Set Command”

5. Answer Setting Status Notification Answer to “Get Command”

6. Information Changing Status Notification ATDM-0604 setting; Information on

changing status

7. Request Action Request Executes action request to Host

① For delimiter, half-width space (␣:0x20) will be used.

② Commands use basically ASCII code. For specific commands UTF-8 is used (Example: Device naming

etc.)

③ The termination of a command is CR(0x0d).

[Example]

s_permissionS000000NC”ATDM-0604”,0,,,,,,,,,↲

factoryACK↲

factoryNAK01↲

g_permission000000NC”ATDM-0604”,0,,,,,,,,,↲

MD open_channel_notice000000NC0,0,0,0,0,0↲

・・・ means space

↲・・・ means CR(0x0d)

・・・ means command parameter

Page 9: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

4

The table below shows command protocol of the action commands.

Table 2-3 Command protocol of action commands

No. Item Content Size Remarks

1. Command Command string 5byte Refer to “3.Table of commands”

2. Handshake

Select

Sequence execution

system

1byte H: Handshake method (Unused)

O: One-Way method

S: ACK/NAK format

3. Model ID Unused 4byte Fixed 0000

4. Unit No Unused 2byte Fixed 00

5. Continue

Select

Divided message system 2byte NC: No divided message

CS: Head of divided message

CM: Divided message

CE: End of divided message

6. Parameter Command parameter 0byte~ Refer to chapter 4

7. End Character Sign for end of message 1byte CR (0x0D)

When a command is sent by the host, the following parameters can be abbreviated. This is done by using

comma (,) punctuation for unspecified data.

Example. When a whole abbreviation of the parameter

[Example] s_permissionS000000NC,,,,,,,,,,↲

However, depending on the command

“Error” can occur when a whole abbreviation of the parameter

“Unspecified” can occur when no abbreviation of the parameter

Cases above and parameters which cannot be abbreviated are described by each command from chapter

4.2 on.

Page 10: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

5

Below, is the acknowledgment command format.

Table 2-4 Response to the acknowledgment command format

No Item Content size Remarks

1. Command Command string 5byte Refer to “3.Table of commands”

2. ACK ACK 3byte Fixed ACK

3. End Character Sign for end of message 1byte CR (0x0D)

Below, is the negative acknowledgment command format.

Table 2-5 Response to negative acknowledgment command format

No Item Content size Remarks

1. Command Command string 5byte Refer to “3.Table of commands”

2. NAK NAK 3byte Fixed NAK

3. Error Code Error code 2byte Refer to Table 2-6

4. End Character Sign for end of message 1byte CR (0x0D)

Below, are the error codes.

Table 2-6 Error Code

Error code Error content Remarks

01 Grammar error ・ No mandatory request

・ Failure in mandatory request command string

・ Defined length of a command string is not appropriate

・ Max. length of command string including line feed code is

exceeded

02 Invalid command ・ Cannot find command

(Refers to an unknown command or a command, which the device

cannot use.)

03 Divided

Transmission Error

・ Referred to “CM” or “CE” in a state, when “CS” Continue Select

is not received.

04 Parameter error ・ Refers to an invalid channel

・ Parameter is out of the defined range

・ When trying to change a parameter, which cannot be changed

(i.e. change “Priority” during talk,...)

05 Transmit timeout Unused

90 Busy Unable to process due to busy state

92 Busy (Safe Mode) Unable to process due to p-Fail (power interruption)

93 Busy (Extension) Unable to process due to Extension mode

99 Other errors Other errors than above

Page 11: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

6

Below, is the setting status notification.

Table 2-7 Command format of setting status notification

No Item Content size Remarks

1. Command Command string 5byte Refer to “3.Table of commands”

2. Model ID Unused 4byte Fixed 0000

3. Unit No Unused 2byte Fixed 00

4. Continue

Select

Divided message system 2byte NC: No divided message

CS: Head of divided message

CM: Divided message

CE: End of divided message

5. Parameter Command parameter 0byte~ Refer to chapter 4

6. End Character Sign for end of message 1byte CR (0x0D)

Below, is the changing status notification.

Table 2-8 Command format of changing status notification

No Item Content size Remarks

1. Modify MD 2byte Fixed MD

2. Command Command string 5byte Refer to “3.Table of commands”

3. Model ID Unused 4byte Fixed 0000

4. Unit No Unused 2byte Fixed 00

5. Continue

Select

Divided message system 2byte NC: No divided message

CS: Head of divided message

CM: Divided message

CE: End of divided message

6. Parameter Command parameter 0byte~ Refer to chapter 4 & 5

7. End Character Sign for end of message 1byte CR (0x0D)

Page 12: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

7

Below, is the requesting status notification (ATDM-0604 では未使用)

Table 2-9 Command format of c status notification

No Item Content size Remarks

1. Request RQ 2byte Fixed RQ

2. Command Command string 5byte Refer to “3.Table of commands”

3. Model ID Unused 4byte Fixed 0000

4. Unit No Unused 2byte Fixed 00

5. Continue

Select

Divided message system 2byte NC: No divided message

CS: Head of divided message

CM: Divided message

CE: End of divided message

6. Parameter Command parameter 0byte~

7. End Character Sign for end of message 1byte CR (0x0D)

Page 13: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

8

3 Table of commands

Table 3-1 Table of commands

No Category Command Command Name Remarks type Ref.

set get info

1. System

Setting factory_settings Factory Default Setting Request

Changes from current state to factory default

setting ○ 17

2. s_permission Permission Setting Change Request Changes permission setting of Administrator ○ 18

3. g_permission Permission Setting Acquisition Request Acquires permission setting of Administrator ○ 19

4. s_network Network Setting Change Request Changes network setting ○ 20

5. g_network Network Setting Acquisition Request Acquires network setting ○ 21

6. g_firmware_version Firmware Version Acquisition Request Acquires firmware version of the ATDM-0604 ○ 22

7. s_header_color Header Color Setting Change Request Changes Header Color setting ○ 23

8. g_header_color Header Color Setting Acquisition Request Acquires Header Color setting ○ 23

9. s_link Audio-Technica LINK Mode Setting Change

Request Changes Audio-Technica LINK Mode setting ○ 24

10. g_link Audio-Technica LINK Mode Setting

Acquisition Request Acquires Audio-Technica LINK Mode setting ○ 24

11. s_connected_limit Connected Device Limit Setting Change

Request

Changes the limitation setting of connectable

device with ADTM-0604 ○ 25

12. g_connected_limit Connected Device Limit Setting acquisition

Request

Acquires the limitation setting of connectable

device with ADTM-0604 ○ 26

13. s_audio_system Audio System Setting Change Request Changes Audio System setting ○ 27

14. g_audio_system Audio System Setting Acquisition Request Acquires Audio System setting ○ 28

15. s_front_panel Front Panel Restriction Setting Change

Request Changes Front Panel Control setting ○ 29

16. g_front_panel Front Panel Restriction Setting Acquisition

Request Acquires Front Panel Control setting ○ 30

17. Audio Setting s_input_gain_level Input Gain&Level Setting Change Request Changes Input Gain&Level setting ○ 31

18. g_input_gain_level Input Gain&Level Setting

AcquisitionRequest Acquires Input Gain&Level setting ○ 32

19. s_output_level Output Level Setting Change Request Changes Output Level setting ○ 33

20. g_output_level Output Level Setting Acquisition Request Acquires Output Level setting ○ 34

21. s_input_channel_settings Input Channel Setting Change Request Changes Input Channel setting ○ 35

22. g_input_channel_settings Input Channel Setting Acquisition Request Acquires Input Channel setting ○ 36

23. s_output_channel_settings Output Setting Change Request Changes Output Channel setting ○ 38

24. g_output_channel_settings Output Setting Acquisition Request Acquires Output Channel setting ○ 39

25. s_input_eq Input EQ Setting Change Request Changes Input 4Band EQ setting ○ 40

26. g_input_eq Input EQ Setting Acquisition Request Acquires Input 4Band EQ setting ○ 41

27. s_output_eq Output EQ Setting Change Request Changes Output 12Band EQ setting ○ 42

28. g_output_eq Output EQ Setting Acquisition Request Acquires Output 12Band EQ setting ○ 43

29. s_fbs FBS Setting Change Request Changes FBS setting ○ 44

30. g_fbs FBS Setting Acquisition Request Acquires FBS setting ○ 45

31. s_fbs_general FBS Common Setting Change Request Changes FBS Common setting ○ 46

32. g_fbs_general FBS Common Setting Acquisition Request Acquires FBS Common setting ○ 47

33. s_dynamics_delay Dynamics&Delay Setting Change Request Changes Dynamics&Delay setting ○ 48

34. g_dynamics_delay Dynamics&Delay Setting Acquisition

Request Acquires Dynamics&Delay setting ○ 49

35. s_aec_nc_general AEC Setting Change Request Changes Dynamics&Delay setting ○ 50

Page 14: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

9

No Category Command Command Name Remarks type Ref.

set get info

36. g_aec_nc_general AEC Setting Acquisition Request Acquires Dynamics&Delay setting ○ 51

37. aec_calibration_test AEC Calibration Test Request Starts AEC test ○ 52

38. aec_calibration_start AEC Calibration Start Request Starts AEC measurement ○ 53

39. aec_calibration_stop AEC Calibration Stop Request Stops AEC measurement ○ 53

40. s_usb_out USB Out Setting Change Request Changes USB Out setting ○ 54

41. g_usb_out USB Out Setting Acquisition Request Acquires USB Out setting ○ 55

42. s_smart_mix Smart Mix Setting Change Request Changes Smart Mix setting in each input channel. ○ 56

43. g_smart_mix Smart Mix Setting acquisition Request Acquires Smart Mix setting in each input channel. ○ 57

44. s_smart_mix_general Smart Mix Common Setting Change

Request Changes Smart Mix Common setting ○ 58

45.

g_smart_mix_general Smart Mix Common Setting Acquisition

Request Acquires Smart Mix Common setting ○ 59

46. s_output_mute Output Mute Setting Change Request Changes output mute setting ○ 60

47. g_output_mute Output Mute Setting Acquisition Request Acquires output mute setting ○ 61

48. Log s_log Logging Setting Change Request Changes Logging On/Off setting and output

destination ○ 62

49. g_log Logging Setting Acquisition Request Acquires Logging On/Off setting and output

destination ○ 63

50. Operater

Page s_operator_general

Web Remote Operator Page Common

Setting Change Request

Changes Web Remote Operator Page common

setting ○ 64

51. g_operator_general Web Remote Operator Page Common

Setting Acquisition Request

Acquires Web Remote Operator Page common

setting ○ 65

52. s_operator_channel Web Remote Operator Page Channel

Setting Change Request

Changes each Channel setting in Web Remote

Operator Page ○ 66

53. g_operator_channel Web Remote Operator Page Channel

Setting Acquisition Request

Acquires Web Remote Operator Page Channel

setting ○ 67

54. Preset call_preset Preset Load Request Loads designated Preset into current data state ○ 69

55. save_preset Preset Save Request Saves current data state into designated Preset ○ 69

56. s_name_bank Preset Name Change Request Changes designated Preset name ○ 70

57. g_name_bank Preset Name Acquisition Request Acquires designated Preset name ○ 71

58. s_bootup_preset Boot Up Preset Setting Change Request Changes the boot up preset No. ○ 72

59. g_bootup_preset Boot Up Preset Setting Acquisition Request Acquires the boot up preset No. ○ 72

60. Other file_transfer File Transfer Request Uploads presets or language file ○ 73

61. file_transfer_cancel File Transfer Cancelling Request Cancels file upload ○ 74

62. export Export Request Exports preset or language file ○ 75

63. import Import Request Imports preset or language file ○ 76

64. s_level_meter_interval Level Meter Interval Change Request Change interval times setting When Notifies Level. ○ 76

65. g_level_meter Level Meter Acquisition Request Acquires Level ○ 77

66. identify Identify Request Blink LED of ATDM-0604 ○ 78

67. date Date Setting Request Changes Date ○ 79

68. reboot Reboot Request Reboots ATDM-0604 to factory default setting ○ 79

69. level_meter_notice Level Meter Notice Notifies Level ○ 81

70. open_channel_notice Open Channel State Notice When Smart Mix setting enable,Notifies Open

Channel status ○ 82

71. cancut_notice Can Cut Notice

When Smart Mix Setting is "Gate" and changes

"Priority" or "Can Cut"in input channel, Notifies

Can Cut status

○ 83

Page 15: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

10

No Category Command Command Name Remarks type Ref.

set get info

72. recall_preset_notice Recall Preset Notice When loads designated Preset into current data

state ,Notifies Load Preset ○ 83

73. input_gain_level_notice Input Gain Level Setting Notice When chaneges gain and level setting in input

channel, Notifies Input Gain and Level ○ 84

74. output_level_notice Output Level Setting Notice When chaneges level setting in output channel,

Notifies Output Level ○ 84

75. fbs_notice FBS Notice When changes FBS state, Notifies FBS status ○ 84

76. operator_channel_notice Web Remote Operator Page Setting Notice When changes level setting into operator

page,Notifies Operator Page Level Setting status ○ 85

77. output_mute_notice Output Mute Setting Notice When changes output mute setting status,Notifies

Output Mute Setting status ○ 85

Page 16: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

11

4 TCP communication

When controlling the ATDM-0604 from the host, communication will be based on TCP protocol.

The graphic below illustrates the communication control flow of the IP control

Graph 4-1 Communication Control Flow

After the system start, “Initializing” follows “Waiting for connection”

After established host connection, on “Waiting for connection” follows “Waiting for

transmission”

The received command will be processed depending on the internal process task and a

result (ACK/NAK) will be sent. But because this process is asynchronous, it is also possible

to receive commands during processing (without waiting for ACK/NAK or Answer, the next

command can be sent). Although based on the command, NAK(90:BUSY) can also occur.

If the host will be disconnected, “Waiting for transmission” changes to “Waiting for

connection”

IP Control Setting Function Host

PowerON

Initialization

Wait for defining IP-Address

(IP config mode)

Generating Socket

Waiting for connection

Establish connection from Host

Waiting to receive

Host sends command

Booting

Processing each command

ACK/NAK or Answer

Decision from Host

Change of setting, state

Sending information to Host (Multicast)

ATDM-0604

~ ~ ~

~ ~ ~

Page 17: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

12

The host establishes a connection to the ATDM-0604.

Simultaneous connection is limited to 5 devices. If this limit is exceeded, the connection will fail.

Table 4-1 Communication control parameter

No Name Default Setting Remarks

1. IPAddress Auto

2. Port No 17300

As “Set Command” response, the ATDM-0604 sends back ACK/NAK to the source.

<Example> Refer below for Factory Default Setting

Graph 4-2 Set Command Processing Sequence

In terms of Set Command, when errors like grammar error, parameter failure etc. occur, the command NAK

will sent to the source.

IP Control Administration Host

Change to Factory

ACK/NAK

ATDM-0604

Setting Function

Default Setting factory_settings

Page 18: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

13

As “Get Command” response, the ATDM-0604 sends back Answer to the source.

<Example> Refer below for Audio Output Setting Acquisition Request sequence.

Graphic 4-3 Get Command Process Sequence

Also for Get Command, when errors like grammar error, parameter failure etc. occur, the command NAK

will sent to the source.

Graphic 4-4 Get Command Process Sequence (NAK)

IP Control Host

Refer to Audio Setting

Answer/CS (output 1)

Answer/CM (output 2)

Answer/CM (output 3)

ATDM-0604

Administration Setting Function

Answer/CE (output 4)

g_output_level

NAK 04

IP Control Host

(Without Mixer Setting)

Refer to Mixer Information

ATDM-0604

Administration Setting Function

g_link

Page 19: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

14

Refer below, in case of ACK/NAK transmitting error sequence.

Graphic 4-6 Transmitting Error Sequence

Refer below, in case of ACK/NAK receiving error sequence.

Graphic 4-7 Receiving Error Sequence

IP Control Host

Change to Factory Default Setting

ACK/NAK

ATDM-0604

Sending error ×

Showing error on frontpanel Time-Out

Showing error

Disconnecting from Host

Administration Setting Function

factory_settings

IP Control Host

Sending error

×

Disconnected

Disconnecting

Showing error

Administration Setting Function

ATDM-0604

factory_settings

Page 20: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

15

Refer below, in case of a Divided Message Receiving Timeout.

Graphic 4-8 Divided Message Receiving Timeout Sequence

The host can disconnect at a random timing while ending the communication.

When a disconnection occurs, the ATDM-0604 clears the status of the applied connection (eg. While

sending a file, etc.) and transitions to “Waiting for connection”. Further, the same process applies also

in case of a disconnected cable etc.

In case of a repeated communication, the host establishes a connection.

IP Control Host

ATDM-0604

Time-Out

Divided receiving

Cancel divided receiving

NAK

Showing error

Administration Setting Function

file_transfer(CS)

file_transfer(CM)

Page 21: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

16

Sent commands are arranged the following way as shown in the example below and as pointed out in each categories "Command fromat table" and "Example".

It is possible to change each parameter, by changing any value which are listed in the table below

Further, it is also possible to change only specific parameters. Parameters, which does not need to be changed, have no entry and will be omitted.

[Example] s_input_channel_settingsS000000NC0,0,1,1,1,1,1,,1,2,,,,,,,,,0,”ATDM-0604”,2E8050↲

No Item Description Type Value Value Description Remarks

1 Command コマンド文字列 string s_input_channel_settings

2 Sequence Select シーケンス実行方式 string S

3 Model ID 未使用 string 0000 未使用

4 Unit No 未使用 string 00 未使用

5 Contine Select メッセージ分割方式 string NC 分割なし

6 Parameter パラメータ 全てを省略は不可

Input Channel Select 入力選択 string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST

Input Source 入力ソース string 0 MIC

1 LINE 0dBV

2 LINE +4dBu

3 LINE -10dBV

4 LINE -20dBV

5 USB STのみ

Phantom power ファンタム電源 string 0 Off

1 On

phase phase string 0 Normal

1 Invert

Low cut ローカット string 0 Off

1 On

AEC ON/OFF AEC string 0 Off

1 On

Smart Mix ON/OFF 許可 string 0 Off

1 ON

Link (Paired) Link5&6 string 0 UnLink Input 5/6 chのみ

1 Link Input 5/6 chのみ

Output BUS

BUS1 出力バス1 string 0 Off

1 Smart Mix Pre Assign Normal Assign

2 Smart Mix Post Assign SmartMix OFF時は無効

BUS2 出力バス2 string 0 Off

1 Smart Mix Pre Assign Normal Assign

2 Smart Mix Post Assign SmartMix OFF時は無効

Reserved パラメータ予備 string 0 許可しない "0"で固定

string 0 許可しない "0"で固定

string 0 許可しない "0"で固定

string 0 許可しない "0"で固定

string 0 許可しない "0"で固定

string 0 許可しない "0"で固定

string 0 許可しない "0"で固定

string 0 許可しない "0"で固定

BUS ST ステレオバス出力 string 0 Off

1 Smart Mix Pre Assign Normal Assign

2 Smart Mix Post Assign SmartMix OFF時は無効

CH Name チャンネル名称 char ”

string ASCⅡコード Maximum 10byte

char ”

CH Color チャンネルの色 string 000000~FFFFFF RRGGBB Red(9B4A42),Green(2E8050),Yellow(A58E36),Br

own(9A6433),Pink(9B4277),Blue(42499B),Gray(

808080),DarkGray(4D4D4D)

7 End Character メッセージの終端文字 binary 0x0d CR

Input Channel Select : Input 1

Input Source : Mic

“Phantom Power” : On

“Phase” : On

“Low Cut” : On

“AEC” : On

“Smart Mix” : On

“Link” : Abbreviating

“Output BUS1” : Smart Mix Pre Assign

“Output BUS2” : Smart Mix Post Assign

“(Reserved)” : ATDM-0604 では未使用

のため”0”で固定。Abbreviating.

“Output BUS ST” : Off

“CH Name” : “ATDM-0604”

“CH Color” : “2E8050”

Page 22: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

17

When the ATDM-0604 receives a Factory Default Setting Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Factory Default Setting Request by the Host, refer to the below command format table.

[Example] factory_settingsS000000NC0↲

Table 4-2 Command format

② ACK/NAK

[Example] factory_settingsACK↲

Table 4-3 Command format

[Example] factory_settingsNAK01↲

Table 4-4 Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string factory_settings

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter - - Disable Parameter

Reset Item

All Setting to Defaulte All Setting to Defaulte string 0 All Reset

Input Setting Input Setting 1 Input 1

2 Input 2

3 Input 3

4 Input 4

5 Input 5

6 Input 6

7 Input ST

AEC Setting AEC Setting 8 AEC Setting

Output Setting Output Setting 9 Output 1

10 Output 2

11 Output ST

4Band EQ 4Band EQ 12 Input 1

13 Input 2

14 Input 3

15 Input 4

16 Input 5

17 Input 6

18 Input ST

12Band EQ 12Band EQ 19 Output 1

20 Output 2

21 Output ST

Operator Page Setting Operator Page Setting 22 Operator Page

7 End Character Ending character of a message binary 0x0d CR

No Item Description type value value Description remarks

1 Command Command String string factory_settings Sets the received Set/Get command

2 ACK ACK string ACK

3 End Character Ending character of a messagebinary 0x0d CR

No Item Description type value value Description remarks

1 Command Command String string factory_settings Sets the received Set/Get command

2 NAK NAK string NAK

3 Error Code Error code string 00~99 Error code Refer to chapter 2.2.4

4 End Character Ending character of a messagebinary 0x0d CR

Page 23: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

18

When the ATDM-0604 receives a Permission Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Permission Setting Change Requestby the Host, refer to the below command format table.

[Example] s_permissionS000000NC”ATDM-0604”,0,,0,,0,0,0,0,0,0↲

table 4-5 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_permission

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Device Name Device Name char " Beginning of the string

string [ASCII] Device Name If " is included,it is defiend

continuously as ""

char " End of the string

Administrator

Password require Password require string 0 Disable password

1 Enable password

password password string [alphanumeric

character]

password In case of abbreviation, it will

change to "not defined".

Independent from the login

(Reserved) (Reserved) string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

7 End Character Ending character of a message binary 0x0d CR

Page 24: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

19

When the ATDM-0604 receives a Permission Setting Acquisition Request, it sends the permission setting in regard to Answer to the host.

① Get Command

In case of a Permission Setting Acquisition Request, refer to the below command format table.

[Example] g_permissionO000000NC↲

Table 4-6 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_permission000000NC”ATDM-0604”,0,,0,,0,0,0,0,0,0↲

Table 4-7 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_permission

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_permission

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

Device Name Device Name char " Beginning of the string

string [ASCII] Device Name If " is included,it is defiend

continuously as ""

char " End of the string

Administrator

Password require Password require string 0 Disable password

1 Enable password

password password string [alphanumeric

character]

password In case of abbreviation, it

will change to "not

defined".

Independent from the login

(Reserved) (Reserved) string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

7 End Character Ending character of a message binary 0x0d CR

Page 25: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

20

When the ATDM-0604 receives a Network Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

Further, in case network settings changed, the ATDM-0604 needs to reboot.

① Set Command

In case of a Network Setting Change Request from the host, refer to the table below.

[Example] s_networkS000000NC1,192.168.033.102,255.255.000.000,,1,17300,1,1,225.000.000.100,17000,0,,,,0,,,,↲

Table 4-8 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_network

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

IP setting

IP config mode IP Address Acquisition Method string 0 Auto

1 Static

IP address IP Address string 000.000.000.000~255.255.255.255 IP Address

Subnet mask Subnet Mask string 000.000.000.000~255.255.255.255 Subnet Mask

Gateway address Default Gateway string 000.000.000.000~255.255.255.255 IP Address

Allow Discovery UPnP Enable or not string 0 Disable

1 Enable

IP control setting

Port Number TCP/IP Port Number string 1~65535 Port Number

Notification Information Transmission

Enable or not

string 0 Disable

1 Enable

Audio Level Notification Audio Level Information

Transmission Enable or not

string 0 Disable

1 Enable

Multicast address Multicast Group Address string 000.000.000.000~255.255.255.255 IP Address

Multicast port number Multicast Port Number string 1~65535 Port Number

NTP setting

Enabled NTP Enable or not string 0 Disable

1 Enable

NTP server address NTP Server Address string 000.000.000.000~255.255.255.255 IP Address

NTP port number NTP Server Port Number string 1~65535 Port Number

Time Zone Difference Time from GMT string -1200~+1400 ±HHMM(30 minute units)

Daylight saving time Daylight Saving Enable or not string 0 Disable

1 Enable

Start Date Daylight Saving Start Date and

Time

string 01010000~12312300 MMDDHHmm(1h units)

End Date Daylight Saving End Date and

Time

string 01010000~12312300 MMDDHHmm(1h units)

(Reserved) (Reserved) string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

7 End Character Ending character of a message binary 0x0d CR

Page 26: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

21

When the ATDM-0604 receives a Network Setting Acquisition Request, it sends the network setting in regard to Answer to the host.

① Get Command

In case of a Network Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_networkO000000NC↲

Table 4-9 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_network000000NC1,,,,,1,17300,1,1,225.000.000.100,17000,0,,,,0,,,,↲

Table 4-10 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_network

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_network

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

IP setting

IP config mode IP Address Acquisition Method string 0 Auto

1 Static

IP address IP Address string 000.000.000.000~255.255.255.255 IP Address

Subnet mask Subnet Mask string 000.000.000.000~255.255.255.255 Subnet Mask

Gateway address Default Gateway string 000.000.000.000~255.255.255.255 IP Address

MAC address MAC Address string XXXXXXYYYYYY MAC Address

Allow Discovery UPnP Enable or not string 0 Disable

1 Enable

IP control setting

Port Number TCP/IP Port Number string 1~99999 Port Number

Notification Information Transmission Enable

or not

string 0 Disable

1 Enable

Audio Level Notification Audio Level Information

Transmission Enable or not

string 0 Disable

1 Enable

Multicast address Multicast Group Address string 000.000.000.000~255.255.255.255 IP Address

Multicast port number Multicast Port Number string 1~99999 Port Number

NTP setting

Enabled NTP Enable or not string 0 Disable

1 Enable

NTP server address NTP Server Address string 000.000.000.000~255.255.255.255 IP Address

NTP port number NTP Server Port Number string 1~99999 Port Number

Time Zone Difference Time from GMT string -1200~+1400 ±HHMM(30 minute units)

Daylight saving time Daylight Saving Enable or not string 0 Disable

1 Enable

Start Date Daylight Saving Start Date and

Time

string 01010000~12312300 MMDDHHmm(1h units)

End Date Daylight Saving End Date and

Time

string 01010000~12312300 MMDDHHmm(1h units)

(Reserved) (Reserved) string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

6 End Character Ending character of a message binary 0x0d CR

Page 27: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

22

When the ATDM-0604 receives a Firmware Version Acquisition Request, it sends the ATDM-0604 firmware version in regard to Answer to the host.

① Get Command

In case of a Firmware Version Acquisition Request form the host, refer to the command format table below.

[Example] g_firmware_versionO000000NC↲

Table 4-11 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_firmware_version000000NC01.00.00↲

Table 4-12 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_firmware_version

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_firmware_version

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

version Firmware version string XX.XX.XX Firmware version

6 End Character Ending character of a message binary 0x0d CR

Page 28: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

23

When the ATDM-0604 receives a Header Color Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Get Command

In case of a Header Color Setting Change Request form the host, refer to the command format table below.

[Example] s_header_colorS000000NCFFFFFF↲

Table 4-13 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

When the ATDM-0604 receives a Header Color Setting Acquisition Request, it sends the Header Color Setting in regard to Answer to the host.

① Get Command

In case of a Header Color Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_header_colorO000000NC↲

Table 4-14 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_header_color000000NCFFFFFF↲

Table 4-15 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string s_header_color

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter - -

Header Color Header Color string 000000~FFFFFF RRGGBB White(FFFFFF),Green(2ECC71),Y

ellow(F1CF3F),Purple(ED5ED8),

Blue(5585EB),Cyan(3DDBC8)

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_header_color

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_header_color

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter - -

Header Color ヘッダーカラー string 000000~FFFFFF RRGGBB White(FFFFFF),Green(2ECC71),Y

ellow(F1CF3F),Purple(ED5ED8),

Blue(5585EB),Cyan(3DDBC8)

6 End Character Ending character of a message binary 0x0d CR

Page 29: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

24

When the ATDM-0604 receives an Audio-Technica LINK Mode Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of an Audio-Technica LINK Mode Setting Change Request form the host, refer to the command format table below.

[Example] s_linkS000000NC1↲

Table 4-16 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

When the ATDM-0604 receives an Audio-Technica LINK Mode Setting Acquisition Request, it sends the Audio-Technica LINK Mode Setting in regard to

Answer to the host.

① Get Command

In case of an Audio-Technica LINK Mode Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_linkO000000NC↲

Table 4-17 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_link000000NC1↲

Table 4-18 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string s_link

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Audio-Technica LINK Mode Audio-Technica LINK Mode string 0 Extention

1 Primary

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_link

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_link

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

Audio-Technica LINK Mode Audio-Technica LINK Mode string 0 Extention

1 Primary

6 End Character Ending character of a message binary 0x0d CR

Page 30: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

25

When the ATDM-0604 receives a Connected Device Limit Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Connected Device Limit Setting Change Request form the host, refer to the command format table below.

[Example] s_connected_limitS000000NC0,,,,,↲

TableTable 4-19 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_connected_limit s_connected_limit

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

Device Access Permission

Restrict Access Restrict Access string 0 Disable

1 Enable

Permission IP Permission IP Addless string 000.000.000.000~2

55.255.255.255

Permission IP 1

000.000.000.000~2

55.255.255.255

Permission IP 2

000.000.000.000~2

55.255.255.255

Permission IP 3

000.000.000.000~2

55.255.255.255

Permission IP 4

000.000.000.000~2

55.255.255.255

Permission IP 5

6 End Character Ending character of a message binary 0x0d CR

Page 31: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

26

When the ATDM-0604 receives a Connected Device Limit Setting acquisition Request, it sends the Connected Device Limit Setting in regard to Answer to

the host.

① Get Command

In case of a Connected Device Limit Setting acquisition Request form the host, refer to the command format table below.

[Example] g_connected_limitO000000NC↲

Table 4-20 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_connected_limit000000NC0,,,,,↲

Table 4-21 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_connected_limit

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_connected_limit g_limit

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

Device Access Permission

Restrict Access Restrict Access string 0 Disable

1 Enable

Permission IP Permission IP Addless string 000.000.000.000~

255.255.255.255

Permission IP 1

000.000.000.000~

255.255.255.255

Permission IP 2

000.000.000.000~

255.255.255.255

Permission IP 3

000.000.000.000~

255.255.255.255

Permission IP 4

000.000.000.000~

255.255.255.255

Permission IP 5

6 End Character Ending character of a message binary 0x0d CR

Page 32: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

27

When the ATDM-0604 receives an Audio System Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of an Audio System Setting Change Request form the host, refer to the command format table below.

[Example] s_audio_systemS000000NC1,0,0,0,1↲

Table 4-22 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_audio_system

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter - -

Gain Unit Type Gain Unit Type string 0 dBu/dBV

1 dB

Delay Unit Type Delay Unit Type string 0 ms

1 M

2 Ft

Output Flip Output Flip string 0 Off

1 On

(Reserved) (Reserved) string 0This parameter is always

0 because is not in use.

Mode change Mode change string 0 Easy Mode

1 Expert Mode

7 End Character Ending character of a message binary 0x0d CR

Page 33: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

28

When the ATDM-0604 receives an Audio System Setting Acquisition Request, it sends the Audio System Setting in regard to Answer to the host.

① Get Command

In case of an Audio System Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_audio_systemO000000NC↲

Table 4-23 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_audio_system000000NC1,0,0,0,1↲

Table 4-24 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_audio_system

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_audio_system

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter - -

Gain Unit Type Gain Unit Type string 0 dBu/dBV

1 dB

Delay Unit Type Delay Unit Type string 0 ms

1 M

2 Ft

Output Flip Output Flip string 0 Off

1 On

(Reserved) (Reserved) string 0This parameter is always 0

because is not in use.

Mode change Mode change string 0 Easy Mode

1 Expert Mode

6 End Character Ending character of a message binary 0x0d CR

Page 34: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

29

When the ATDM-0604 receives a Front Panel Restriction Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Front Panel Restriction Setting Change Request form the host, refer to the command format table below.

[Example] s_front_panelS000000NC1,1,1,1,1,1,0,0,0,0,1,0,1,1,1,1,1,0↲

Table 4-25 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_front_panel

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter - -

Input Lock

Input 1 Input 1 string 0 Disable

1 Enable

Input 2 Input 2 string 0 Disable

1 Enable

Input 3 Input 3 string 0 Disable

1 Enable

Input 4 Input 4 string 0 Disable

1 Enable

Input 5 Input 5 string 0 Disable

1 Enable

Input 6 Input 6 string 0 Disable

1 Enable

(Reserved) (Reserved) string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

Input ST Input ST string 0 Disable

1 Enable

Input USB Input USB string 0 Disable

1 Enable

Output Lock

Output 1 Output 1 string 0 Disable

1 Enable

Output 2 Output 2 string 0 Disable

1 Enable

Output ST Output ST string 0 Disable

1 Enable

Setting Lock

Recall Recall string 0 Disable

Preset Preset 1 Enable

Entering Entering string 0 Disable

Advanced Mode Advanced Mode 1 Enable

LED Dimmer LED Dimmer string 0 Off

1 On

7 End Character Ending character of a message binary 0x0d CR

Page 35: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

30

When the ATDM-0604 receives a Front Panel Restriction Setting Acquisition Request, it sends the Front Panel Restriction Setting in regard to Answer to

the host.

① Get Command

In case of a Front Panel Restriction Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_front_panelO000000NC↲

Table 4-26 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_front_panelO000000NC1,1,1,1,1,1,0,0,0,0,1,0,1,1,1,1,1,0↲

Table 4-27 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_front_panel

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_front_panel

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter - -

Input Lock

Input 1 Input 1 string 0 Disable

1 Enable

Input 2 Input 2 string 0 Disable

1 Enable

Input 3 Input 3 string 0 Disable

1 Enable

Input 4 Input 4 string 0 Disable

1 Enable

Input 5 Input 5 string 0 Disable

1 Enable

Input 6 Input 6 string 0 Disable

1 Enable

(Reserved) (Reserved) string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

string 0This parameter is always 0

because is not in use.

Input ST Input ST string 0 Disable

1 Enable

Input USB Input USB string 0 Disable

1 Enable

Output Lock

Output 1 Output 1 string 0 Disable

1 Enable

Output 2 Output 2 string 0 Disable

1 Enable

Output ST Output ST string 0 Disable

1 Enable

Setting Lock

Recall Recall string 0 Disable

Preset Preset 1 Enable

Entering Entering string 0 Disable

Advanced Mode Advanced Mode 1 Enable

LED Dimmer LED Dimmer string 0 Off

1 On

6 End Character Ending character of a message binary 0x0d CR

Page 36: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

31

When the ATDM-0604 receives an Input Gain&Level Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of an Input Gain&Level Setting Change Request form the host, refer to the command format table below.

[Example] s_input_gain_levelS000000NC0,0,0,0,0,511,0↲

Table 4-28 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_input_gain_level

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST

gain

Mic Mic gain string 0~40 +20dB to +60dB Refer to 6.5 Input Gain Table

Line Line gain string 0~40 -20dBu to -60dBu Refer to 6.5 Input Gain Table

Level Level string 0~511 -∞,-120 to +10dB Refer to 6.1 Fader Table

Max Volume Enable Max Volume On/Off string 0 Off

1 On

Max Volume Max Volume string 0~511 -∞,-120 to +10dB Refer to 6.1 Fader Table

Mute Mute string 0 Off

1 ON

7 End Character Ending character of a message binary 0x0d CR

Page 37: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

32

When the ATDM-0604 receives an Input Gain&Level Setting AcquisitionRequest, it sends the Input Gain&Level Setting in regard to Answer to the host.

① Get Command

In case of an Input Gain&Level Setting AcquisitionRequest form the host, refer to the command format table below.

[Example] g_input_gain_levelO000000NC0↲

Table 4-29 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_input_gain_level000000NC0,0,0,0,0,511,0↲

Table 4-30 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_input_gain_level

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_input_gain_level

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST

gain

Mic Mic gain string 0~40 +20dB to +60dB Refer to 6.5 Input Gain Table

Line Line gain string 0~40 -20dBu to -60dBu Refer to 6.5 Input Gain Table

Level Level string 0~511 -∞,-120 to +10dB Refer to 6.1 Fader Table

Max Volume Enable Max Volume On/Off string 0 Off

1 ON

Max Volume Max Volume string 0~511 -∞,-120 to +10dB Refer to 6.1 Fader Table

Mute Mute string 0 Off

1 ON

6 End Character Ending character of a message binary 0x0d CR

Page 38: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

33

When the ATDM-0604 receives an Output Level Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of an Output Level Setting Change Request form the host, refer to the command format table below.

[Example] s_output_levelS000000NC0,111,0,511↲

Table 4-31 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_output_level

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

Level Level string 0~511 -∞,-120 to +10dB Refer to 6.1 Fader Table

Max Volume Enable Max Volume On/Off string 0 Off

1 ON

Max Volume Max Volume string 0~511 -∞,-120 to +10dB Refer to 6.1 Fader Table

7 End Character Ending character of a message binary 0x0d CR

Page 39: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

34

When the ATDM-0604 receives an Output Level Setting Acquisition Request, it sends the Output Level Setting in regard to Answer to the host.

① Get Command

In case of an Output Level Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_output_levelO000000NC0↲

Table 4-32 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_output_level000000NC0,0,0,0↲

Table 4-33 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_output_level

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_output_level

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

Level Level string 0~511 -∞,-120 to +10dB Refer to 6.1 Fader Table

Max Volume Enable Max Volume On/Off string 0 Off

1 ON

Max Volume Max Volume string 0~511 -∞,-120 to +10dB Refer to 6.1 Fader Table

6 End Character Ending character of a message binary 0x0d CR

Page 40: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

35

When the ATDM-0604 receives an Input Channel Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of an Input Channel Setting Change Request form the host, refer to the command format table below.

[Example] s_input_channel_settingsS000000NC0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,,2E8050↲

Table 4-34 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_input_channel_settings

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST

Input Source Input Source string 0 MIC

1 LINE 0dBV

2 LINE +4dBu

3 LINE -10dBV

4 LINE -20dBV

5 USB ST only

Phantom power Phantom power string 0 Off

1 On

phase phase string 0 Normal

1 Invert

Low cut Low cut string 0 Off

1 On

AEC ON/OFF AEC string 0 Off

1 On

Smart Mix ON/OFF Smart Mix ON/OFF string 0 Off

1 ON

Link 5&6 Link 5&6 string 0 UnLink Input 5/6 ch only

1 Link Input 5/6 ch only

Output Bus

Bus 1 Output Bus 1 string 0 Off

1 Smart Mix Pre Assign Normal Assign

2 Smart Mix Post Assign disabled if Smart Mix is not active

Bus 2 Output Bus 2 string 0 Off

1 Smart Mix Pre Assign Normal Assign

2 Smart Mix Post Assign disabled if Smart Mix is not active

Reserved Reserved string 0 This parameter is always 0 because is

not in use.

string 0 This parameter is always 0 because is

not in use.

string 0 This parameter is always 0 because is

not in use.

string 0 This parameter is always 0 because is

not in use.

string 0 This parameter is always 0 because is

not in use.

string 0 This parameter is always 0 because is

not in use.

string 0 This parameter is always 0 because is

not in use.

string 0 This parameter is always 0 because is

not in use.

Bus ST Output Bus ST string 0 Off

1 Smart Mix Pre Assign Normal Assign

2 Smart Mix Post Assign disabled if Smart Mix is not active

CH Name Channel Name char ”

string [ASCⅡ] Maximum 10byte

char ”

CH Color Channel Color string 000000~FFFFFF RRGGBB Red(9B4A42),Green(2E8050),Yellow(A58E3

6),Brown(9A6433),Pink(9B4277),Blue(4249

9B),Gray(808080),DarkGray(4D4D4D)

7 End Character Ending character of a message binary 0x0d CR

Page 41: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

36

When the ATDM-0604 receives an Input Channel Setting Acquisition Request, it sends the Input Channel Settings in regard to Answer to the host.

① Get Command

In case of an Input Channel Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_input_channel_settingsO000000NC0↲

Table 4-35 Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_input_channel_settings

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST

7 End Character Ending character of a message binary 0x0d CR

Page 42: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

37

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_input_channel_settingsO000000NC0,,,,,,,,,,,,,,,,,,,,,↲

Table 4-36 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_input_channel_settings

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST

Input Source Input Source string 0 MIC

1 LINE 0dBV

2 LINE +4dBu

3 LINE -10dBV

4 LINE -20dBV

5 USB ST only

Phantom power Phantom power string 0 Off

1 On

phase phase string 0 Normal

1 Invert

Low cut Low cut string 0 Off

1 On

AEC ON/OFF AEC string 0 Off

1 On

Smart Mix ON/OFF Smart Mix ON/OFF string 0 Off

1 ON

Link 5&6 Link 5&6 string 0 UnLink Input 5/6 ch only

1 Link Input 5/6 ch only

Output Bus

Bus1 Output Bus 1 string 0 Off

1 Smart Mix Pre Assign Normal Assign

2 Smart Mix Post Assign disabled if Smart Mix is not active

Bus2 Output Bus 2 string 0 Off

1 Smart Mix Pre Assign Normal Assign

2 Smart Mix Post Assign disabled if Smart Mix is not active

Reserved Reserved string 0 This parameter is always 0 because

is not in use.

0 This parameter is always 0 because

is not in use.

0 This parameter is always 0 because

is not in use.

0 This parameter is always 0 because

is not in use.

0 This parameter is always 0 because

is not in use.

0 This parameter is always 0 because

is not in use.

0 This parameter is always 0 because

is not in use.

0 This parameter is always 0 because

is not in use.

Bus ST Output Bus ST string 0 Off

1 Smart Mix Pre Assign Normal Assign

2 Smart Mix Post Assign disabled if Smart Mix is not active

CH Name Channel Name char ”

string [ASCⅡ] Maximum 10byte

char ”

CH Color Channel Color string 000000~FFFFFF RRGGBB Red(9B4A42),Green(2E8050),Yellow(

A58E36),Brown(9A6433),Pink(9B427

7),Blue(42499B),Gray(808080),DarkG

6 End Character Ending character of a message binary 0x0d CR

Page 43: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

38

When the ATDM-0604 receives an Output Channel Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a nOutput Channel Setting Change Request form the host, refer to the command format table below.

[Example] s_output_channel_settingsS000000NC0,0,,2E8050↲

Table 4-37 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_output_channel_settings

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

Output Type Output Type string 0 +4dBu

1 0dBV

2 -10dBV

3 -33dBV

CH Name Channel Name char ”

string [ASCⅡ] Maximum 10byte

char ”

CH Color Channel Color string 000000~FFFFFF RRGGBB Red(9B4A42),Green(2E8050),Yellow(A58

E36),Brown(9A6433),Pink(9B4277),Blue

(42499B),Gray(808080),DarkGray(4D4D

4D)7 End Character Ending character of a message binary 0x0d CR

Page 44: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

39

When the ATDM-0604 receives an Output Channel Setting Acquisition Request, it sends the Output Channel Settings in regard to Answer to the host.

① Get Command

In case of an Output Channel Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_output_channel_settingsO000000NC0↲

Table 4-38 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_output_channel_settingsO000000NC0,0,,2E8050↲

Table 4-39 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_output_channel_settings

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Input Channel Select Input Channel Select string 0 Output 1

1 Output 2

10 Output ST

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_output_channel_settings

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

Output Type Output Type string 0 +4dBu

1 0dBV

2 -10dBV

3 -33dBV

CH Name Channel Name char ”

string [ASCⅡ] Maximum 10byte

char ”

CH Color Channel Color string 000000~FFFFFF RRGGBB Red(9B4A42),Green(2E8050),Yello

w(A58E36),Brown(9A6433),Pink(9

B4277),Blue(42499B),Gray(808080

),DarkGray(4D4D4D)

6 End Character Ending character of a message binary 0x0d CR

Page 45: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

40

When the ATDM-0604 receives an Input EQ Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of an Input EQ Setting Change Request form the host, refer to the command format table below.

[Example] s_input_eqS000000NC0,0,0,2,16,36,6,1,80,36,6,1,400,36,6,1,2,464,36,6↲

Table 4-40 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_input_eq

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST1

EQ CH ON/OFF EQ CH ON/OFF string 0 Off

1 On

Band# Band1

EQ Enable EQ Enable string 0 Off If enable/disable band1 EQ of

ATDM-0604, it affects band 1 to 4

entirely.

1 On It controls entire bands not only

for band1.

Filter Factors Filter type Filter type string 0 LPF/HPF

1 LSH/HSH

2 PEQ Band2 and Band3 are fixed to

PEQ.

Frequency Frequency string 0~480 20Hz~20kHz Refer to 6.2 Frequency Table

Gain Gain string 0~72 -18dB~+18dB Refer to 6.4 EQ Gain Table

Q value Q value string 0~31 0.3~60 Refer to 6.3 Q Value Table

Band# Band2

EQ Enable EQ Enable string 0 Off

1 On

Filter Factors Frequency Frequency string 0~480 20Hz~20kHz Refer to 6.2 Frequency Table

Gain Gain string 0~72 -18dB~+18dB Refer to 6.4 EQ Gain Table

Q value Q value string 0~31 0.3~60 Refer to 6.3 Q Value Table

Band# Band3 It has same parameter as band2.

Band# Band4 It has same parameter as band1.

7 End Character Ending character of a message binary 0x0d CR

Page 46: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

41

When the ATDM-0604 receives an Input EQ Setting Acquisition Request, it sends the Input EQ Setting in regard to Answer to the host.

① Get Command

In case of an Input EQ Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_input_eqO000000NC0↲

Table 4-41 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_input_eqO000000NC0,0,0,2,16,36,6,1,80,36,6,1,400,36,6,1,2,464,36,6↲

Table 4-42 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_input_eq

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_input_eq

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST1

EQ CH ON/OFF EQ CH ON/OFF string 0 Off

1 On

Band# Band1

EQ Enable EQ Enable string 0 Off If enable/disable band1 EQ of

ATDM-0604, it affects band 1 to 4

entirely.

1 On It controls entire bands not only for

band1.

Filter Factors Filter type Filter type string 0 LPF/HPF

1 LSH/HSH

2 PEQ Band2 and Band3 are fixed to PEQ.

Frequency Frequency string 0~480 20Hz~20kHz Refer to 6.2 Frequency Table

Gain Gain string 0~72 -18dB~+18dB Refer to 6.4 EQ Gain Table

Q value Q value string 0~31 0.3~60 Refer to 6.3 Q Value Table

Band# Band2

EQ Enable EQ Enable string 0 Off

1 On

Filter Factors Frequency Frequency string 0~480 20Hz~20kHz Refer to 6.2 Frequency Table

Gain Gain string 0~72 -18dB~+18dB Refer to 6.4 EQ Gain Table

Q value Q value string 0~31 0.3~60 Refer to 6.3 Q Value Table

Band# Band3 It has same parameter as band2.

Band# Band4 It has same parameter as band1.

6 End Character Ending character of a message binary 0x0d CR

Page 47: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

42

When the ATDM-0604 receives an Output EQ Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of an Output EQ Setting Change Request form the host, refer to the command format table below.

[Example] s_output_eq000000NC0,0,1,2,0,36,6,1,28,36,6,1,76,36,6,1,124,36,6,1,172,36,6,1,224,36,6,1,272,3

6,6,1,320,36,6,1,368,36,6,1,416,36,6,1,464,36,6,1,2,480,36,6↲

Table 4-43Command format

① ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_output_eq

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

EQ CH ON/OFF EQ CH ON/OFF string 0 Off

1 On

Band# Band1

EQ Enable EQ Enable string 0 Off

1 On

Filter Factors Filter type Filter type string 0 LPF/HPF

1 LSH/HSH

2 PEQ Band2 to Band11 are fixed to PEQ.

Frequency Frequency string 0~480 20Hz~20kHz Refer to 6.2 Frequency Table

Gain Gain string 0~72 -18dB~+18dB Refer to 6.4 EQ Gain Table

Q value Q value string 0~31 0.3~60 Refer to 6.3 Q Value Table

Band# Band2

EQ Enable EQ Enable string 0 Off

1 On

Filter Factors Frequency Frequency string 0~480 20Hz~20kHz Refer to 6.2 Frequency Table

Gain Gain string 0~72 -18dB~+18dB Refer to 6.4 EQ Gain Table

Q value Q value string 0~31 0.3~60 Refer to 6.3 Q Value Table

Band# Band3 It has same parameter as band2.

Band# Band4 It has same parameter as band2.

Band# Band5 It has same parameter as band2.

Band# Band6 It has same parameter as band2.

Band# Band7 It has same parameter as band2.

Band# Band8 It has same parameter as band2.

Band# Band9 It has same parameter as band2.

Band# Band10 It has same parameter as band2.

Band# Band11 It has same parameter as band2.

Band# Band12 It has same parameter as band1.

7 End Character Ending character of a message binary 0x0d CR

Page 48: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

43

When the ATDM-0604 receives an Output EQ Setting Acquisition Request, it sends the Output EQ Setting in regard to Answer to the host.

① Get Command

In case of an Output EQ Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_output_eqO000000NC↲

Table 4-44 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_output_eq000000NC0,0,1,2,0,36,6,1,28,36,6,1,76,36,6,1,124,36,6,1,172,36,6,1,224,36,6,1,272,3

6,6,1,320,36,6,1,368,36,6,1,416,36,6,1,464,36,6,1,2,480,36,6↲

Table 4-45 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_output_eq

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_output_eq

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

EQ CH ON/OFF EQ CH ON/OFF string 0 Off

1 On

Band# Band1

EQ Enable EQ Enable string 0 Off

1 On

Filter Factors Filter type Filter type string 0 LPF/HPF

1 LSH/HSH

2 PEQ Band2 to Band3 are fixed to PEQ.

Frequency Frequency string 0~480 20Hz~20kHz Refer to 6.2 Frequency Table

Gain Gain string 0~72 -18dB~+18dB Refer to 6.4 EQ Gain Table

Q value Q value string 0~31 0.3~60 Refer to 6.3 Q Value Table

Band# Band2

EQ Enable EQ Enable string 0 Off

1 On

Filter Factors Frequency Frequency string 0~480 20Hz~20kHz Refer to 6.2 Frequency Table

Gain Gain string 0~72 -18dB~+18dB Refer to 6.4 EQ Gain Table

Q value Q value string 0~31 0.3~60 Refer to 6.3 Q Value Table

Band# Band3 It has same parameter as band2.

Band# Band4 It has same parameter as band2.

Band# Band5 It has same parameter as band2.

Band# Band6 It has same parameter as band2.

Band# Band7 It has same parameter as band2.

Band# Band8 It has same parameter as band2.

Band# Band9 It has same parameter as band2.

Band# Band10 It has same parameter as band2.

Band# Band11 It has same parameter as band2.

Band# Band12 It has same parameter as band1.

7 End Character Ending character of a message binary 0x0d CR

Page 49: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

44

When the ATDM-0604 receives a FBS Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a FBS Setting Change Request form the host, refer to the command format table below.

[Example] s_fbsS000000NC0,0,0,,,,,,,,↲

Table 4-46Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_fbs

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

Processing Type Processing Type 0 Band setting

1 Reset

2 Copy to Output EQ

Enable FBS Enable string 0 Off

1 On

Band# Band1

Filter Factors Static Static Select string 0 Dynamics

2 Statics

Band# Band2 It has same parameter as band1.

Band# Band3 It has same parameter as band1.

Band# Band4 It has same parameter as band1.

Band# Band5 It has same parameter as band1.

Band# Band6 It has same parameter as band1.

Band# Band7 It has same parameter as band1.

Band# Band8 It has same parameter as band1.

7 End Character Ending character of a message binary 0x0d CR

Page 50: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

45

When the ATDM-0604 receives a FBS Setting Acquisition Request, it sends the FBS Setting in regard to Answer to the host.

① Get Command

In case of a FBS Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_fbsO000000NC0↲

Table 4-47Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_fbs000000NC0,0,0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,↲

Table 4-48 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_fbs

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_fbs

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

Processing Type Processing Type 0 Band setting

1 Reset Not in use

2 Copy to Output EQ Not in use

Enable Enable string 0 Off

1 On

Band# Band1

Filter Factors Static Static Select string 0 Dynamics

2 Statics

Frequency Frequency string 0~480 20Hz~20kHz Refer to 6.2 Frequency Table

Gain Gain string 0~72 -18dB~+18dB Refer to 6.4 EQ Gain Table

Q value Q value string 0~31 0.3~60 Refer to 6.3 Q Value Table

Band# Band2 It has same parameter as band1.

Band# Band3 It has same parameter as band1.

Band# Band4 It has same parameter as band1.

Band# Band5 It has same parameter as band1.

Band# Band6 It has same parameter as band1.

Band# Band7 It has same parameter as band1.

Band# Band8 It has same parameter as band1.

6 End Character Ending character of a message binary 0x0d CR

Page 51: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

46

When the ATDM-0604 receives a FBS Common Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a FBS Common Setting Change Request form the host, refer to the command format table below.

[Example] s_fbs_generalS000000NC2,1↲

Table 4-49Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_fbs_general

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Derection Derection string 0 Low

1 Mid

2 High

Response Response string 0 slow

1 fast

7 End Character Ending character of a message binary 0x0d CR

Page 52: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

47

When the ATDM-0604 receives a FBS Common Setting Acquisition Request, it sends the FBS Common Setting in regard to Answer to the host.

① Get Command

In case of a FBS Common Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_fbs_generalO000000NC↲

Table 4-50 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_fbs_general000000NC2,1↲

Table 4-51 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_fbs_general

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No item Description Type Value Value Description Remarks

1 Command Command String string g_fbs_general

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

Derection Derection string 0 Low

1 Mid

2 High

Response Response string 0 slow

1 fast

6 End Character Ending character of a message binary 0x0d CR

Page 53: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

48

When the ATDM-0604 receives a Dynamics&Delay Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Dynamics&Delay Setting Change Request form the host, refer to the command format table below.

[Example] s_dynamics_delay000000NC0,0,50,1,100,400,10,0,0,0↲

Table 4-52 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_dynamics_delay

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

Output Channel Select Output channel select string 0 OUT 1

1 OUT 2

10 OUT ST

Dynamics

Dynamics Enable Dynamics On/Off string 0 Off

1 On

Compressor Threshold Compressor Threshold string 0~60 -60 to 0dB 1.0 step

Compressor Ratio Compressor Ratio string 0 1:1.4

1 1:2

2 1:4

3 1:6

4 1:10

5 +∞

Compressor Attack Compressor Attackstring 0,25,50,100,200,400,800

,1600,3200,100000 to 100msec

Compressor Release Compressor Releasestring 50,100,200,400,800,100

0,200050 to 2000msec

Output Gain Output Gain string 0~20 10 to -10dB

Limiter Threshold Limiter Threshold string 0~60 -60 to 0dB 1.0 step

Delay Delay string 0 Off

1 On

Delay Time Delay Time string 0~1000 0 to 1000msec 1.0 step

7 End Character Ending character of a message binary 0x0d CR

Page 54: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

49

When the ATDM-0604 receives a Dynamics&Delay Setting Acquisition Request, it sends the Dynamics&Delay Setting in regard to Answer to the host.

① Get Command

In case of a Dynamics&Delay Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_dynamics_delayO000000NC↲

Table 4-53Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_dynamics_delay000000NC0,0,50,1,100,400,10,0,0,0↲

Table 4-54 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_dynamics_delay

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_dynamics_delay

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

Dynamics

Dynamics Enable Dynamics On/Off string 0 Off

1 On

Compressor Threshold Compressor Threshold string 0~60 -60 to 0dB 1.0 step

Compressor Ratio Compressor Ratio string 0 1:1.4

1 1:2

2 1:4

3 1:6

4 1:10

5 +∞

Compressor Attack Compressor Attackstring 0,25,50,100,200,400,80

0,1600,3200,100000 to 100msec

Compressor Release Compressor Releasestring 50,100,200,400,800,100

0,200050 to 2000msec

Output Gain Output Gain string 0~20 10 to -10dB

Limiter Threshold Limiter Threshold string 0~60 -60 to 0dB 1.0 step

Delay Delay string 0 Off

1 On

Delay Time Delay Time string 0~1000 0 to 1000msec 1.0 step

6 End Character Ending character of a message binary 0x0d CR

Page 55: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

50

When the ATDM-0604 receives an AEC Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of an AEC Setting Change Request form the host, refer to the command format table below.

[Example] s_aec_generalS000000NC0,0,60,0,0,0,100,100,1,0,0↲

Table 4-55 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_aec_nc_general

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

AEC Mode AEC Mode string 0 Off

1 AEC

2 Noise Canceling

AEC Reference AEC Reference string 0 IN 1

1 IN 2

2 IN 3

3 IN 4

4 IN 5

5 IN 6

10 IN ST

12 OUT 1

13 OUT 2

22 OUT ST When Output Flip is ON,"ST" changed "L/R"

23 External

Reference Level Reference Level string 0~40 -20~+20dB 1.0 step

Send Reference Send Reference string 0 Off

1 On

AEC Sensitivity AEC Sensitivity string 0 Low

1 High

Output Bus Output Bus string 0 BUS1

1 BUS2

2 BUS ST

Noise Cancel Attenuation Level

AEC AEC string 0~200 0 to 100 1.0 step

Noise Canceling Noise Canceling string 0~200 0 to 100 1.0 step

Non Lineer Processing Non Lineer Processing string 0 Off

1 On

Non Lineer Processing Sensitivity Non Lineer Processing Sensitivity string 0 Low

1 High

AEC Status Apply Save AEC Parameter string 0 Off

1 On It will return to 0 after FIR is saved

7 End Character Ending character of a message binary 0x0d CR

Page 56: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

51

When the ATDM-0604 receives an AEC Setting Acquisition Request, it sends the AEC Setting in regard to Answer to the host.

① Get Command

In case of an AEC Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_aec_generalO000000NC0↲

Table 4-56 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_aec_general000000NC0,0,60,0,0,0,100,100,1,0,0↲

Table 4-57 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_aec_nc_general

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_aec_nc_general

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

AEC Mode AEC Mode string 0 Off

1 AEC

2 Noise Canceling

AEC Reference AEC Reference string 0 IN 1

1 IN 2

2 IN 3

3 IN 4

4 IN 5

5 IN 6

10 IN ST

12 OUT 1

13 OUT 2

22 OUT ST When Output Flip is ON,"ST" changed "L/R"

23 External

Reference Level Reference Level string 0~40 -20~+20dB 1.0 step

Send Reference Send Reference string 0 Off

1 On

AEC Sensitivity AEC Sensitivity string 0 Low

1 High

Output Bus Output Bus string 0 BUS1

1 BUS2

2 BUS ST

Noise Cancel Attenuation Level

AEC AEC string 0~200 0 to 100 1.0 step

Noise Canceling Noise Canceling string 0~200 0 to 100 1.0 step

Non Lineer Processing Non Lineer Processing string 0 Off

1 On

Non Lineer Processing Sensitivity Non Lineer Processing Sensitivity string 0 Low

1 High

AEC Status Apply Save AEC Parameter string 0 Off

1 On It will return to 0 after FIR is saved

6 End Character Ending character of a message binary 0x0d CR

Page 57: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

52

When the ATDM-0604 receives an AEC Calibration Test Request、It sends the processing result to Information to the host.

① Set Command

In case of an AEC Calibration Test Request form the host, refer to the command format table below.

[Example] aec_calibration_testS000000NC↲

Table 4-58 Command format

② AEC Calibration Measurment Result Notice

When Host send AEC Calibration test request, ATDM-0604 send the test result or timeout message to information to the host.

Measurement result notification is called ace calibration notice, and is send to the PC that started measurement.

In case of a AEC calibration Measurement Result Notice to the host, refer to the command format table below.

[Example] MD_aec_calibration_notice 0000 0 NC 0,0,0↲

Table 4-59 Answer Command format

Also, Information is described later in Chapter5.

No Item Description Type Value Value Description Remarks

1 Command Command String string aec_calibration_test

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string aec_calibration_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Result Result string 0 Normal

1 Reverb Time NG While the reverbe time is

more than 250ms.

2 Delay Time NG While the delay time is

more than 160ms.

3 Time Out If thirty seconds passed

since command is sent.

Reverb Time Reverb Time string 0~ Reverb Time (ms) it's 0ms in test mode.

Delay Time Delay Time string 0~ Delay Time (ms) it's 0ms in test mode.

7 End Character Ending character of a message binary 0x0d CR

Page 58: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

53

When the ATDM-0604 receives an AEC Calibration Start Request、It sends the processing result to Information to the host.

① Set Command

In case of an AEC Calibration Start Request form the host, refer to the command format table below.

[Example] aec_calibration_startS000000NC↲

Table 4-60 Command format

② AEC Calibration Measurment Result Notice

When Host send AEC Calibration Start request, ATDM-0604 send the test result or timeout message to information to the host.

Measurement result notification is called ace calibration notice, and is send to the PC that started measurement.

In case of a AEC calibration Measurement Result Notice to the host, refer to the command format table below.

[Example] MD_aec_calibration_notice00000NC↲

Table 4-61 Answer Command format

Also, Information is described later in Chapter5.

When the ATDM-0604 receives an AEC Calibration Stop Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of an AEC Calibration Stop Request form the host, refer to the command format table below.

[Example] aec_calibration_stopS000000NC↲

Table 4-62 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string aec_calibration_start

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string aec_calibration_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Result Result string 0 Normal

1 Reverb Time NG While the reverbe time

is more than 250ms.

2 Delay Time NG While the delay time is

more than 160ms.

3 Time Out If thirty seconds passed

since command is sent.

Reverb Time Reverb Time string 0~ Reverb Time (ms) it's 0ms in test mode.

Delay Time Delay Time string 0~ Delay Time (ms) it's 0ms in test mode.

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string aec_calibration_stop

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

Page 59: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

54

When the ATDM-0604 receives a USB Out Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a USB Out Setting Change Request form the host, refer to the command format table below.

[Example] s_usb_outS000000NC0,411↲

Table 4-63 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_usb_out

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

USB Out

Source Select Source pattern select

Pattern1 string 0 Off

Pattern2 string 1 OUT1

Pattern3 string 2 OUT2

Pattern4 string 3 ST

Pattern5 string 4 AEC

Pattern6 string 5 OUT1/OUT2

Pattern7 string 6 OUT1/AEC

Pattern8 string 7 OUT2/AEC

Send Level Send Level for USB Out string 0~411 -∞,-120 to 0dB Refer to 6.1 Fader Table

7 End Character Ending character of a message binary 0x0d CR

Page 60: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

55

When the ATDM-0604 receives a USB Out Setting Acquisition Request, it sends the USB Out Setting in regard to Answer to the host.

① Get Command

In case of a USB Out Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_usb_outO000000NC↲

Table 4-64 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_usb_out000000NC0,411↲

Table 4-65 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_usb_out

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_usb_out

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not

available

USB Out

Source Select Source pattern select

Pattern1 string 0 Off

Pattern2 string 1 OUT1

Pattern3 string 2 OUT2

Pattern4 string 3 ST

Pattern5 string 4 AEC

Pattern6 string 5 OUT1/OUT2

Pattern7 string 6 OUT1/AEC

Pattern8 string 7 OUT2/AEC

Send Level Send Level for USB Out string 0~411 -∞,-120 to 0dB Refer to 6.1 Fader Table

6 End Character Ending character of a message binary 0x0d CR

Page 61: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

56

When the ATDM-0604 receives a Smart Mix Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Smart Mix Setting Change Request form the host, refer to the command format table below.

[Example] s_smart_mixS000000NC0,30,,,,0,0,40↲

Table 4-66 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_smart_mix

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

Smart Mix

Gain Share

Weight Gain Share Weight 0.5 step

Group Group string 0~60 -15 to 15

(Reserved) (Reserved)string 0 This parameter is always 0

because is not in use.

(Reserved) (Reserved)string 0 This parameter is always 0

because is not in use.

(Reserved) (Reserved)string 0 This parameter is always 0

because is not in use.

Gate

Priority Priority string 0 Off

1 On

Can Cut Can Cut string 0 Off

1 On

Off attenuation of closed mic Off attenuation of closed mic string 0~60 0~-60dB 1.0 step

7 End Character Ending character of a message binary 0x0d CR

Page 62: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

57

When the ATDM-0604 receives a Smart Mix Setting acquisition Request, it sends the Smart Mix Setting in regard to Answer to the host.

① Get Command

In case of a Smart Mix Setting acquisition Request form the host, refer to the command format table below.

[Example] g_smart_mixO000000NC0↲

Table 4-67 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_smart_mix000000NC0,,30,,,,0,0,40↲

Table 4-68 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_smart_mix

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_smart_mix

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

Input Channel Select Input channel select string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

Smart Mix

Gain Share

Weight Gain Share Weight 0.5 step

Group Group string 0~60 -15 to 15

(Reserved) (Reserved)string 0 This parameter is always 0

because is not in use.

(Reserved) (Reserved)string 0 This parameter is always 0

because is not in use.

(Reserved) (Reserved)string 0 This parameter is always 0

because is not in use.

Gate

Priority Priority string 0 Off

1 On

Can Cut Can Cut string 0 Off

1 On

Off attenuation of closed mic Off attenuation of closed mic string 0~60 0~-60dB 1.0 step

6 End Character Ending character of a message binary 0x0d CR

Page 63: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

58

When the ATDM-0604 receives a Smart Mix Common Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Smart Mix Common Setting Change Request form the host, refer to the command format table below.

[Example] s_smart_mix_generalS000000NC2,0,2500,0,6,1↲

Table 4-69 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_smart_mix_general

2 Sequence Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is

not available

General Setting

Smart Mix Mode Smart Mix Mode string 0 Off

1 Gate

2 Gain Share

Last Mic ON Last Mic ON string 0 Off

1 On

Gate Hold Time Gate Hold Time

string 500,1000,1500,2000,2500,300

0,3500,4000,4500,5000,5500,

6000,6500,7000,7500,8000,85

00,9000,9500,10000

500~10000 msec

NOMA NOMA string 0 Off

1 On

Num Of Open Mic Num Of Open Mic string 1~6 1 mic~6mic

Priority Mode Priority Mode string 0 Mode1

1 Mode2

7 End Character Ending character of a message binary 0x0d CR

Page 64: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

59

When the ATDM-0604 receives a Smart Mix Common Setting acquisition Request, it sends the Smart Mix Common Setting in regard to Answer to the host.

① Get Command

In case of a Smart Mix Common Setting acquisition Request form the host, refer to the command format table below.

[Example] g_smart_mix_generalO000000NC↲

Table 4-70 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_smart_mix_general000000NC2,0,2500,0,6,1↲

Table 4-71 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_smart_mix_general

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_smart_mix_general

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is

not available

General Setting

Smart Mix Mode Smart Mix Mode string 0 Off

1 Gate

2 Gain Share

Last Mic ON Last Mic ON string 0 Off

1 On

Gate Hold Time Gate Hold Time

string 500,1000,1500,2000,2

500,3000,3500,4000,4

500,5000,5500,6000,6

500,7000,7500,8000,8

500,9000,9500,10000

500~10000 msec

NOMA NOMA string 0 Off

1 On

Num Of Open Mic Num Of Open Mic string 1~6 1 mic~6mic

Priority Mode Priority Mode string 0 Mode1

1 Mode2

6 End Character Ending character of a messagebinary 0x0d CR

Page 65: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

60

When the ATDM-0604 receives an Output Mute Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

Output Mute Setting is saved in presets.

When the ATDM-0604 restarts, it takes over the output mute setting before restarting.

① Set Command

In case of an Output Mute Setting Setting Change Request form the host, refer to the command format table below.

[Example] s_output_muteS000000NC0,0↲

Table 4-72 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_output_mute

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

Mute Mute string 0 Off

1 ON

7 End Character Ending character of a message binary 0x0d CR

Page 66: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

61

When the ATDM-0604 receives an Output Mute Setting Acquisition Request, it sends the Output Mute Setting in regard to Answer to the host.

① Get Command

In case of an Output Mute Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_output_muteO000000NC0↲

Table 4-73 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_output_mute000000NC0,0↲

Table 4-74 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_output_mute

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Output Channel Select Output channel select string 0 Output 1

1 Output 2

10 Output ST

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_output_mute

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter Abbreviating all is not available

Output Channel Select Output Channel Select string 0 Output 1

1 Output 2

10 Output ST

Mute Mute string 0 Off

1 ON

7 End Character binary 0x0d CR

Page 67: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

62

When the ATDM-0604 receives a Logging Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Logging Setting Change Request form the host, refer to the command format table below.

[Example] s_logS000000NC1,0↲

Table 4-75 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_log

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter Abbreviating all is not available

Enabled Enabled string 0 Off

1 On

Output destination Output destination string 0 Internal

2 Syslog

7 End Character Ending character of a message binary 0x0d CR

Page 68: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

63

When the ATDM-0604 receives a Logging Setting Acquisition Request, it sends the Logging Setting in regard to Answer to the host.

③ Get Command

In case of a Logging Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_logO000000NC↲

Table 4-76 Command format

④ Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_log000000NC1,0↲

Table 4-77 Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_log

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_log

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

Enabled Enabled string 0 Off

1 On

Output destination Output destination string 0 Internal

2 Syslog

6 End Character Ending character of a message binary 0x0d CR

Page 69: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

64

When the ATDM-0604 receives a Web Remote Operator Page Common Setting Change Request, it sends the processing result regarding ACK or NAK to

the host.

① Set Command

In case of a Web Remote Operator Page Common Setting Change Request form the host, refer to the command format table below.

[Example] s_operator_generalS000000NC1,6,0,1,0↲

Table 4-78 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_operator_general

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Operator Page Restrictions

Recall Preset Recall Preset string 0 Off

1 On

Number of Preset Number of Preset string 1 1

2 2

3 3

4 4

5 5

6 6

Fader position Resume Fader position Resume string 0 Off

1 On

Logout Buttan Logout Buttan string 0 Off

1 On

(Reserved) (Reserved) string 0This parameter is always 0

because is not in use.

7 End Character Ending character of a message binary 0x0d CR

Page 70: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

65

When the ATDM-0604 receives a Web Remote Operator Page Common Setting Acquisition Request, it sends the Web Remote Operator Page Setting in

regard to Answer to the host.

① Get Command

In case of a Web Remote Operator Page Common Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_operator_pageO000000NC↲

Table 4-79 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_operator_page000000NC1,6,0,1,0↲

Table 4-80 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_operator_general

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_operator_general

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

Operator Page Restrictions

Recall Preset Recall Preset string 0 Off

1 On

Number of Preset Number of Preset string 1 1

2 2

3 3

4 4

5 5

6 6

Fader position Resume Fader position Resume string 0 Off

1 On

Logout Buttan Logout Buttan string 0 Off

1 On

(Reserved) (Reserved) string 0This parameter is always 0

because is not in use.

6 End Character Ending character of a message binary 0x0d CR

Page 71: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

66

When the ATDM-0604 receives a Web Remote Operator Page Channel Setting Change Request, it sends the processing result regarding ACK or NAK to

the host.

① Set Command

In case of a Web Remote Operator Page Channel Setting Change Request form the host, refer to the command format table below.

[Example] s_operator_channelS000000NC1,0,”Mic”,0,70,0,100,1,0,0,0,0,0,0,0,0,0↲

Table 4-81 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_operator_channel

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Fader Channel

Fader Channel Select Fader Channel Select string 1 Fader Ch1

2 Fader Ch2

3 Fader Ch3

4 Fader Ch4

5 Fader Ch5

6 Fader Ch6

7 Fader Ch7

8 Fader Ch8

Fader Setting

Show Show string 0 Off

1 On

Name Name char "

string [ASCⅡ] Maximum 10 Character

char "

Icon Icon string 0 Mic

1 Aux

2 PC

3 Chat

4 Spk

5 Rec

Level Level string 0~100 0 to 100 1.0step

Max Volume Enable Max Volume On/Off string 0 Off

1 On When turneed ON,set to value

Max Volume Max Volume string 0~100 0 to 100 1.0step

Assign

Input1 Input1 string 0 Off Assignment of Fader channel for IN or OUT

1 On channel is exclusive.

Input2 Input2 string 0 Off

1 On

Input3 Input3 string 0 Off

1 On

Input4 Input4 string 0 Off

1 On

Input5 Input5 string 0 Off

1 On

Input6 Input6 string 0 Off

1 On

Input ST Input ST string 0 Off

1 On

Output 1 Output 1 string 0 Off You can select from OUT1, OUT2 and ST.

1 On And you can not select the OUT CH that

Output 2 Output 2 string 0 Off is selected already in other channel.

1 On

Output ST Output ST string 0 Off

1 On

7 End Character Ending character of a message binary 0x0d CR

Page 72: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

67

When the ATDM-0604 receives a Web Remote Operator Page Channel Setting Acquisition Request, it sends the Web Remote Operator Page Channel

Setting in regard to Answer to the host.

① Get Command

In case of a Web Remote Operator Page Channel Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_operator_channelO000000NC1↲

Table 4-82 Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_operator_channel

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Fader Channel

Fader Channel Setting Fader Channel Setting string 1 Fader Ch1

2 Fader Ch2

3 Fader Ch3

4 Fader Ch4

5 Fader Ch5

6 Fader Ch6

7 Fader Ch7

8 Fader Ch8

7 End Character Ending character of a message binary 0x0d CR

Page 73: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

68

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_operator_channelS000000NC1,0,”Mic”,0,70,0,100,1,0,0,0,0,0,0,0,0,0↲

Table 4-83 Answer Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_operator_channel

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

Fader Channel

Fader Channel Setting フェーダチャンネル設定 string 1 Fader Ch1

2 Fader Ch2

3 Fader Ch3

4 Fader Ch4

5 Fader Ch5

6 Fader Ch6

7 Fader Ch7

8 Fader Ch8

Fader Setting

Show Show string 0 Off

1 On

Name Name char "

string [ASCⅡ] Maximum 10 Character

char "

Icon Icon string 0 Mic

1 Aux

2 PC

3 Chat

4 Spk

5 Rec

Level Level string 0~100 0 to 100 1.0step

Max Volume Enable Max Volume On/Off string 0 Off

1 On When turneed ON,set to value

Max Volume Max Volume string 0~100 0 to 100 1.0step

Assign

Input1 Input1 string 0 Off Assignment of Fader channel for IN or OUT

1 On channel is exclusive.

Input2 Input2 string 0 Off

1 On

Input3 Input3 string 0 Off

1 On

Input4 Input4 string 0 Off

1 On

Input5 Input5 string 0 Off

1 On

Input6 Input6 string 0 Off

1 On

Input ST Input ST string 0 Off

1 On

Output 1 Output 1 string 0 Off You can select from OUT1, OUT2 and ST.

1 On And you can not select the OUT CH that

Output 2 Output 2 string 0 Off is selected already in other channel.

1 On

Output ST Output ST string 0 Off

1 On

6 End Character Ending character of a message binary 0x0d CR

Page 74: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

69

When the ATDM-0604 receives a Preset Load Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Preset Load Request form the host, refer to the command format table below.

[Example] call_presetS000000NC1↲

Table 4-84 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

When the ATDM-0604 receives a Preset Save Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Preset Save Request form the host, refer to the command format table below.

[Example] save_presetS000000NC1↲

Table 4-85 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string call_preset

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Preset Number Preset Number string 1~6 Preset1~6 abbreviating not available

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string save_preset

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Preset Number Preset Number string 1~6 Preset1~6 abbreviating not available

7 End Character Ending character of a message binary 0x0d CR

Page 75: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

70

When the ATDM-0604 receives a Preset Name Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Preset Name Change Request form the host, refer to the command format table below.

[Example] s_name_bankS000000NC1,”BANK01”↲

Table 4-86 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_name_bank

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Preset Number Preset Number string 1~6 Disable division abbreviating not available

Preset Name Preset Name string " Beginning of the string abbreviating not available

[UTF-8] 10 Characters If " is included, it is defined continuously as ""

" End of the string abbreviating not available

7 End Character Ending character of a message binary 0x0d CR

Page 76: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

71

When the ATDM-0604 receives a Preset Name Acquisition Request, it sends the Preset Name in regard to Answer to the host.

① Get Command

In case of a Preset Name Acquisition Request form the host, refer to the command format table below.

[Example] g_name_bankO000000NC↲

Table 4-87 Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_name_bank000000CS1,”BANK01”↲

g_name_bank000000CS2,”BANK02”↲

g_name_bank000000CS6,”BANK06”↲

Table 4-88 Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_name_bank

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_name_bank

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string CS/CM/CE Disable division

5 Parameter Parameter

Preset Number Preset Number string 1~6 Disable division abbreviating not available

Preset Name Preset Name string " Beginning of the string abbreviating not available

[UTF-8] 10 Characters If " is included, it is defined continuously as ""

" End of the string abbreviating not available

6 End Character Ending character of a message binary 0x0d CR

Page 77: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

72

When the ATDM-0604 receives a Boot Up Preset Setting Change Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Boot Up Preset Setting Change Request form the host, refer to the command format table below.

[Example] s_bootup_presetS000000NC0↲

Table 4-89 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

When the ATDM-0604 receives a Boot Up Preset Setting Acquisition Request, it sends the Boot Up Preset Setting in regard to Answer to the host.

① Get Command

In case of a Boot Up Preset Setting Acquisition Request form the host, refer to the command format table below.

[Example] g_bootup_presetO000000NC

Table 4-90 Answer Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_bootup_preset000000NC0↲

Table 4-91 Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string s_bootup_preset

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Preset Number Preset Number string 0 Disable

1~6 Preset1~6

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_bootup_preset

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string g_bootup_preset

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

Preset Number Preset Number string 0 Disable

1~6 Preset1~6

6 End Character Ending character of a message binary 0x0d CR

Page 78: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

73

When the ATDM-0604 receives a File Transfer Request, it sends the processing result regarding ACK or NAK to the host

① Set Command

In case of a File Transfer Request form the host, refer to the command format table below.

[Example] file_transferS000000CSp1000004001024[binary data]↲

file_transferS000000CMp1000008001024[binary data]↲

file_transferS000000CMp1000010001024[binary data]↲

file_transferS000000CEp100001400256[binary data]↲

Table 4-92 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string file_transfer

2 HandShake Select Sequence execution methodstring S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division methodstring NC/CS/CM/CE With segmentation

6 Parameter Parameter

Kind Transfer data Kind Refer to 6.4 Transfer data Kind abbreviating not available

File offset File offset string 00000000~

FFFFFFFF

Set offset value in the update file by

hexadecimal. Not giving "0x".

Return value from Ftell(FILE*) function.

abbreviating not available

Size Size string 0001~1024 Set the byte count of the size of transfer

data by decimal.

abbreviating not available

Data Data binary - Set the transfer data by binary digits. abbreviating not available

7 End Character Ending character of a messagebinary 0x0d CR

Page 79: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

74

When the ATDM-0604 receives a File Transfer Cancelling Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a File Transfer Cancelling Request form the host, refer to the command format table below.

[Example] file_transfer_cancelS000000NCp1↲

Table 4-93 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string file_transfer_cancel

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Kind Transfer data Kind Refer to 6.4 Transfer data Kind abbreviating not available

7 End Character Ending character of a message binary 0x0d CR

Page 80: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

75

When the ATDM-0604 receives a Export Request, it sends the Export in regard to Answer to the host.

① Get Command

In case of a Export Request form the host, refer to the command format table below.

[Example] exportO000000NCp1↲

Table 4-94Command format

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] export000000CSp1000004001024[binary data]↲

export000000CMp1000008001024[binary data]↲

export000000CMp1000010001024[binary data]↲

export000000CEp100001400256[binary data]↲

Table 4-95 Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string export

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Kind Transfer data Kind Refer to 6.4 Transfer data Kind abbreviating not available

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string export

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC/CS/CM/CE With segmentation

5 Parameter Parameter

Kind Transfer data Kind Refer to 6.4 Transfer data Kind abbreviating not available

File offset File offset string 00000000~

FFFFFFFF

Set offset value in the update file by

hexadecimal. Not giving "0x".

Return value from Ftell(FILE*) function.

abbreviating not available

Size Size string 0001~1024 Set the byte count of the size of transfer

data by decimal.

abbreviating not available

Data Data binary - Set the transfer data by binary digits. abbreviating not available

6 End Character Ending character of a message binary 0x0d CR

Page 81: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

76

When the ATDM-0604 receives an Import Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of an Import Request form the host, refer to the command format table below.

[Example] importS000000NCp1↲

Table 4-96 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

When the ATDM-0604 receives a Level Meter Interval Change Request, it sends the processing result regarding ACK or NAK to the host.

① Get Command

In case of a Level Meter Interval Change Request form the host, refer to the command format table below.

[Example] s_level_meter_intervalS000000NC100↲

Table 4-97 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string import

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Kind Transfer data kind Refer to 6.4 Transfer data Kind abbreviating not available

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string s_level_meter_interval

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter abbreviating all is not available

Interval Intervel time string 100~ msec Preliminary set to over 100msec

7 End Character Ending character of a message binary 0x0d CR

Page 82: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

77

When the ATDM-0604 receives a Level Meter Acquisition Request, it sends the Level Meter in regard to Answer to the host.

① Get Command

In case of a Level Meter Acquisition Request form the host, refer to the command format table below.

[Example] g_level_meterO000000NC0↲

Table 4-98 Command format

No Item Description Type Value Value Description Remarks

1 Command Command String string g_level_meter

2 HandShake Select Sequence execution method string O

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

monitor point

Post Fader metor PostFader metor string 0 Input 1 Show the level of input and

1 Input 2 output page.

2 Input 3

3 Input 4

4 Input 5

5 Input 6

6 Input ST L

7 Input ST R

8 Output 1

9 Output 2

10 Output ST L

11 Output ST R

Pre Fader metor PreFader metor string 12 Input 1 Show the input level while

13 Input 2 changing gain.

14 Input 3

15 Input 4

16 Input 5

17 Input 6

18 Input ST L

19 Input ST R

AEC AEC string 20 ERL show the attenuation in the

21 ERLE level of AEC noise and echo .

22 TER

23 Reference Level

Gain Share Gain Share string 24 Input 1 Show the level that is adjusted

25 Input 2 automatically by Gain Share

26 Input 3 feature.

27 Input 4

28 Input 5

29 Input 6

30 Input ST L

31 Input ST R

Dynamics Dynamics

Input Input string 32 Output 1 Show the input level of

33 Output 2 dynamics.

34 Output ST L

35 Output ST R

Gain Reductiojn Gain Reduction string 36 Output 1 Show the gain level suppressed

37 Output 2 by compressor feature .

38 Output ST L

39 Output ST R

Output Output string 40 Output 1 Show the dynamics output level.

41 Output 2

42 Output ST L

43 Output ST R

7 End Character Ending character of a message binary 0x0d CR

Page 83: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

78

② Answer

Refer to the table below for Answer Command format from the ATDM-0604.

[Example] g_level_meter000000NC0,0↲

Table 4-99 Command format

When the ATDM-0604 receives a Identify Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Identify Request form the host, refer to the command format table below.

[Example] identifyS000000NC↲

Table 4-100 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string g_level_meter

2 Model ID Not in use string 0000 Not in use

3 Unit No Not in use string 00 Not in use

4 Contine Select Massage division method string NC Disable division

5 Parameter Parameter

monitor point monitor point string 0~43 Meter number Refer to Level Parameter

Aquistion Request

level level string 0~61 level

6 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string identify

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

Page 84: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

79

When the ATDM-0604 receives a Date Setting Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Date Setting Request form the host, refer to the command format table below.

[Example] s_dateS000000NC20170125000000↲

Table 4-101 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

When the ATDM-0604 receives a Reboot Request, it sends the processing result regarding ACK or NAK to the host.

① Set Command

In case of a Reboot Request form the host, refer to the command format table below.

[Example] rebootS000000NC↲

Table 4-102 Command format

② ACK/NAK

Refer to Factory Default Setting Request②.

No Item Description Type Value Value Description Remarks

1 Command Command String string s_date

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Date Date string YYYYMMDDHHMMSS Date and Time (A.D.) abbreviating not

available

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Command Command String string reboot

2 HandShake Select Sequence execution method string S

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

7 End Character Ending character of a message binary 0x0d CR

Page 85: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

80

5 UDP communication

For Information (State Change Notification) sent from the ATDM-0604, UDP protocol will be used.

Refer to chapter 4.1, for communication control flow

The Host executes a group registration for Multicast address.

Table 5-1 Communication Control Parameter

No Name Default Setting Remarks

1. IPAddress 225.000.000.100 Multicast address

2. Port No 17000

If the state of the ATDM-0604 changes, the below State Change Notification will be executed.

<Example> Refer below for a conference state notification sequence.

Graphic 5-1 Information Command Process Sequence

Refer to chapter 4.1.3.1 for transmitting error sequence.

The Host can delete the group registration at a random timing.

Open_Chann

el_notice

IP Control Host

Change of

ATDM-0604

Administration Setting Function

conference setting

Page 86: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

81

Level Meter Notification will be sent from the ATDM-0604 periodically.

Will be notified, in an interval set by the level meter setting request. (Default 100msec)

Will not be sent in case of 0 (not used) by IP Control Setting Audio Level Notification of Network setting (4.2.4).

[Example] MDlevel_meter_notice000000NC61,61,61,61,61,61,61,61,61,61,61,61,60,60,60,60,60,60,60,

60,60,60,60,60,60,15,15,15,15,15,15,15,15,28,28,28,28,28,28,28,28,28,28,28,28↲

Table 5-2 Command format

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string level_meter_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Post Fader Meter

Level 0 Input 1 string 0~61 Level of Input 1

Level 1 Input 2 string 0~61 Level of Input 2

Level 2 Input 3 string 0~61 Level of Input 3

Level 3 Input 4 string 0~61 Level of Input 4

Level 4 Input 5 string 0~61 Level of Input 5

Level 5 Input 6 string 0~61 Level of Input 6

Level 6 Input ST L string 0~61 Level of Input ST L

Level 7 Input ST R string 0~61 Level of Input ST R

Level 8 Output 1 string 0~61 Level of Output 1

Level 9 Output 2 string 0~61 Level of Output 2

Level 10 Output ST L string 0~61 Level of Output ST L

Level 11 Output ST R string 0~61 Level of Output ST R

Pre Fader metor

Level 12 Input 1 string 0~60 Level of Input 1

Level 13 Input 2 string 0~60 Level of Input 2

Level 14 Input 3 string 0~60 Level of Input 3

Level 15 Input 4 string 0~60 Level of Input 4

Level 16 Input 5 string 0~60 Level of Input 5

Level 17 Input 6 string 0~60 Level of Input 6

Level 18 Input ST L string 0~60 Level of Input ST L

Level 19 Input ST R string 0~60 Level of Input ST R

AEC

Level 20 ERL string 0~60 Level of ERL

Level 21 ERLE string 0~60 Level of ERLE

Level 22 TER string 0~60 Level of TER

Level 23 Reference Level string 0~60 Level of Reference

Gain Share

Level 24 Input 1 string 0~15 Level of Input 1

Level 25 Input 2 string 0~15 Level of Input 2

Level 26 Input 3 string 0~15 Level of Input 3

Level 27 Input 4 string 0~15 Level of Input 4

Level 28 Input 5 string 0~15 Level of Input 5

Level 29 Input 6 string 0~15 Level of Input 6

Level 30 Input ST L string 0~15 Level of Input ST L

Level 31 Input ST R string 0~15 Level of Input ST R

Dynamics

Level 32 Output 1 string 0~28 Level of Output 1

Level 33 Output 2 string 0~28 Level of Output 2

Level 34 Output ST L string 0~28 Level of Output ST L

Level 35 Output ST R string 0~28 Level of Output ST R

Level 36 Output 1 string 0~28 Level of Output 1

Level 37 Output 2 string 0~28 Level of Output 2

Level 38 Output ST L string 0~28 Level of Output ST L

Level 39 Output ST R string 0~28 Level of Output ST R

Level 40 Output 1 string 0~28 Level of Output 1

Level 41 Output 2 string 0~28 Level of Output 2

Level 42 Output ST L string 0~28 Level of Output ST L

Level 43 Output ST R string 0~28 Level of Output ST R

7 End Character Ending character of a message binary 0x0d CR

Page 87: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

82

When the Smart Mix is Enable and Active information is changed, Open Channel State Notification will be sent from the ATDM-0604.

Will not be sent in case of 0 (not used) by IP Control Setting Notification of Network setting (4.2.4).

[Example] MDopen_channel_notice000000NC1,1,1,1,1,1↲

Table 5-3 Command format

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string open_channel_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Input

Input 1 Input 1 string 0 Close

1 Open

Input 2 Input 2 string 0 Close

1 Open

Input 3 Input 3 string 0 Close

1 Open

Input 4 Input 4 string 0 Close

1 Open

Input 5 Input 5 string 0 Close

1 Open

Input 6 Input 6 string 0 Close

1 Open

7 End Character Ending character of a message binary 0x0d CR

Page 88: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

83

When Smart Mix Setting is "Gate" and changes "Priority" or "Can Cut"in input channel, Can Cut state Notification will be sent from the ATDM-0604.

Will not be sent in case of 0 (not used) by IP Control Setting Notification of Network setting (4.2.4).

[Example] MD_cancut_notice000000NC0,0,0,0,0,0↲

When loads designated Preset into current data state, Preset load Notification will be sent from the ATDM-0604.

Will not be sent in case of 0 (not used) by IP Control Setting Notification of Network setting (4.2.4).

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string cancut_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Input

Input 1 Input 1 string 0 Off If even one Off of "Priorty" and "Can

Cut".

1 On When Both "Priority" and "Can Cut"

are Enable.

Input 2 Input 2 string 0 Off It has same parameter as Input1.

1 On

Input 3 Input 3 string 0 Off It has same parameter as Input1.

1 On

Input 4 Input 4 string 0 Off It has same parameter as Input1.

1 On

Input 5 Input 5 string 0 Off It has same parameter as Input1.

1 On

Input 6 Input 6 string 0 Off It has same parameter as Input1.

1 On

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string recall_preset_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Preset Number Preset Number string 1~6 Preset1~6

7 End Character Ending character of a message binary 0x0d CR

Page 89: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

84

When chaneges gain and level setting in input channel, Input Gain and Level setting Notification will be sent from the ATDM-0604.

Will not be sent in case of 0 (not used) by IP Control Setting Notification of Network setting (4.2.4)

When changes level setting in output channel , Output Level Setting Notification will be sent from the ATDM-0604.

Will not be sent in case of 0 (not used) by IP Control Setting Notification of Network setting (4.2.4).

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string input_gain_level_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Input Channel Input Channel string 0 Input 1

1 Input 2

2 Input 3

3 Input 4

4 Input 5

5 Input 6

10 Input ST

gain

Mic Mic string0~40 +20dB to +60dB

Refer to 6.5 Input Gain

Table

Line Line string0~40 -20dBu to -60dBu

Refer to 6.5 Input Gain

Table

Level Level string 0~511 -∞,-120 to +10dB Refer to 6.1 Fader Table

Mute Mute string 0 Off

1 ON

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string output_level_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Output Channel Output Channel string 0 Output 1

1 Output 2

10 Output ST

Level Level string 0~511 -∞,-120 to +10dB Refer to 6.1 Fader Table

7 End Character Ending character of a message binary 0x0d CR

Page 90: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

85

When changes FBS state, FBS Notification will be sent from the ATDM-0604.

Will not be sent in case of 0 (not used) by IP Control Setting Notification of Network setting (4.2.4).

When changes level setting into operator page, Operator Channel setting Notification will be sent from the ATDM-0604.

Will not be sent in case of 0 (not used) by IP Control Setting Notification of Network setting (4.2.4).

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string fbs_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Output Channel Select Output Channel Select string 0 Output 1

1 Output 2

10 Output ST

Processing Type Processing Type string 0 Band setting

Enable FBS On/Off string 0 Off

1 On

Band# Band1

Filter Factors Static Static string 0 Dynamics

2 Statics

Frequency Frequency string 0~480 20Hz~20kHz Refer to 6.2 Frequency Table

Gain Gain string 0~72 -18dB~+18dB Refer to 6.4 EQ Gain Table

Q value Q value string 0~31 0.3~60 Refer to 6.3 Q Value Table

Band# Band2 It has same parameter as Band1.

Band# Band3 It has same parameter as Band1.

Band# Band4 It has same parameter as Band1.

Band# Band5 It has same parameter as Band1.

Band# Band6 It has same parameter as Band1.

Band# Band7 It has same parameter as Band1.

Band# Band8 It has same parameter as Band1.

7 End Character Ending character of a message binary 0x0d CR

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string operator_channel_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Fader Channel

Fader Channel Fader Channel string 1 Fader Ch1

2 Fader Ch2

3 Fader Ch3

4 Fader Ch4

5 Fader Ch5

6 Fader Ch6

7 Fader Ch7

8 Fader Ch8

Fader Setting

Level Level string 0~100 0 to 100 1.0step

7 End Character Ending character of a message binary 0x0d CR

Page 91: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

86

When changes output mute setting, Output Mute Setting Notification will be sent from the ATDM-0604.

Will not be sent in case of 0 (not used) by IP Control Setting Notification of Network setting (4.2.4).

No Item Description Type Value Value Description Remarks

1 Modify MD string MD

2 Command Command String string output_mute_notice

3 Model ID Not in use string 0000 Not in use

4 Unit No Not in use string 00 Not in use

5 Contine Select Massage division method string NC Disable division

6 Parameter Parameter

Output Channel Output Channel string 0 Output 1

1 Output 2

10 Output ST

Mute Mute string 0 Off

1 ON

7 End Character Ending character of a message binary 0x0d CR

Page 92: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

87

6 Appendix

Value Data[dB] Value Data[dB] Value Data[dB] Value Data[dB] Value Data[dB] Value Data[dB] Value Data[dB] Value Data[dB]0 -Infinity 64 -63.5 128 -36.6 192 -23.8 256 -15.5 320 -9.1 384 -2.7 448 3.71 -120.0 65 -63.0 129 -36.4 193 -23.6 257 -15.4 321 -9.0 385 -2.6 449 3.82 -118.0 66 -62.5 130 -36.2 194 -23.4 258 -15.3 322 -8.9 386 -2.5 450 3.93 -116.0 67 -62.0 131 -36.0 195 -23.2 259 -15.2 323 -8.8 387 -2.4 451 4.04 -114.0 68 -61.5 132 -35.8 196 -23.0 260 -15.1 324 -8.7 388 -2.3 452 4.15 -112.0 69 -61.0 133 -35.6 197 -22.8 261 -15.0 325 -8.6 389 -2.2 453 4.26 -110.0 70 -60.5 134 -35.4 198 -22.6 262 -14.9 326 -8.5 390 -2.1 454 4.37 -108.0 71 -60.0 135 -35.2 199 -22.4 263 -14.8 327 -8.4 391 -2.0 455 4.48 -106.0 72 -59.5 136 -35.0 200 -22.2 264 -14.7 328 -8.3 392 -1.9 456 4.59 -104.0 73 -59.0 137 -34.8 201 -22.0 265 -14.6 329 -8.2 393 -1.8 457 4.610 -102.0 74 -58.5 138 -34.6 202 -21.8 266 -14.5 330 -8.1 394 -1.7 458 4.711 -100.0 75 -58.0 139 -34.4 203 -21.6 267 -14.4 331 -8.0 395 -1.6 459 4.812 -99.0 76 -57.5 140 -34.2 204 -21.4 268 -14.3 332 -7.9 396 -1.5 460 4.913 -98.0 77 -57.0 141 -34.0 205 -21.2 269 -14.2 333 -7.8 397 -1.4 461 5.014 -97.0 78 -56.5 142 -33.8 206 -21.0 270 -14.1 334 -7.7 398 -1.3 462 5.115 -96.0 79 -56.0 143 -33.6 207 -20.8 271 -14.0 335 -7.6 399 -1.2 463 5.216 -95.0 80 -55.5 144 -33.4 208 -20.6 272 -13.9 336 -7.5 400 -1.1 464 5.317 -94.0 81 -55.0 145 -33.2 209 -20.4 273 -13.8 337 -7.4 401 -1.0 465 5.418 -93.0 82 -54.5 146 -33.0 210 -20.2 274 -13.7 338 -7.3 402 -0.9 466 5.519 -92.0 83 -54.0 147 -32.8 211 -20.0 275 -13.6 339 -7.2 403 -0.8 467 5.620 -91.0 84 -53.5 148 -32.6 212 -19.9 276 -13.5 340 -7.1 404 -0.7 468 5.721 -90.0 85 -53.0 149 -32.4 213 -19.8 277 -13.4 341 -7.0 405 -0.6 469 5.822 -89.0 86 -52.5 150 -32.2 214 -19.7 278 -13.3 342 -6.9 406 -0.5 470 5.923 -88.0 87 -52.0 151 -32.0 215 -19.6 279 -13.2 343 -6.8 407 -0.4 471 6.024 -87.0 88 -51.5 152 -31.8 216 -19.5 280 -13.1 344 -6.7 408 -0.3 472 6.125 -86.0 89 -51.0 153 -31.6 217 -19.4 281 -13.0 345 -6.6 409 -0.2 473 6.226 -85.0 90 -50.5 154 -31.4 218 -19.3 282 -12.9 346 -6.5 410 -0.1 474 6.327 -84.0 91 -50.0 155 -31.2 219 -19.2 283 -12.8 347 -6.4 411 0.0 475 6.428 -83.0 92 -49.5 156 -31.0 220 -19.1 284 -12.7 348 -6.3 412 0.1 476 6.529 -82.0 93 -49.0 157 -30.8 221 -19.0 285 -12.6 349 -6.2 413 0.2 477 6.630 -81.0 94 -48.5 158 -30.6 222 -18.9 286 -12.5 350 -6.1 414 0.3 478 6.731 -80.0 95 -48.0 159 -30.4 223 -18.8 287 -12.4 351 -6.0 415 0.4 479 6.832 -79.5 96 -47.5 160 -30.2 224 -18.7 288 -12.3 352 -5.9 416 0.5 480 6.933 -79.0 97 -47.0 161 -30.0 225 -18.6 289 -12.2 353 -5.8 417 0.6 481 7.034 -78.5 98 -46.5 162 -29.8 226 -18.5 290 -12.1 354 -5.7 418 0.7 482 7.135 -78.0 99 -46.0 163 -29.6 227 -18.4 291 -12.0 355 -5.6 419 0.8 483 7.236 -77.5 100 -45.5 164 -29.4 228 -18.3 292 -11.9 356 -5.5 420 0.9 484 7.337 -77.0 101 -45.0 165 -29.2 229 -18.2 293 -11.8 357 -5.4 421 1.0 485 7.438 -76.5 102 -44.5 166 -29.0 230 -18.1 294 -11.7 358 -5.3 422 1.1 486 7.539 -76.0 103 -44.0 167 -28.8 231 -18.0 295 -11.6 359 -5.2 423 1.2 487 7.640 -75.5 104 -43.5 168 -28.6 232 -17.9 296 -11.5 360 -5.1 424 1.3 488 7.741 -75.0 105 -43.0 169 -28.4 233 -17.8 297 -11.4 361 -5.0 425 1.4 489 7.842 -74.5 106 -42.5 170 -28.2 234 -17.7 298 -11.3 362 -4.9 426 1.5 490 7.943 -74.0 107 -42.0 171 -28.0 235 -17.6 299 -11.2 363 -4.8 427 1.6 491 8.044 -73.5 108 -41.5 172 -27.8 236 -17.5 300 -11.1 364 -4.7 428 1.7 492 8.145 -73.0 109 -41.0 173 -27.6 237 -17.4 301 -11.0 365 -4.6 429 1.8 493 8.246 -72.5 110 -40.5 174 -27.4 238 -17.3 302 -10.9 366 -4.5 430 1.9 494 8.347 -72.0 111 -40.0 175 -27.2 239 -17.2 303 -10.8 367 -4.4 431 2.0 495 8.448 -71.5 112 -39.8 176 -27.0 240 -17.1 304 -10.7 368 -4.3 432 2.1 496 8.549 -71.0 113 -39.6 177 -26.8 241 -17.0 305 -10.6 369 -4.2 433 2.2 497 8.650 -70.5 114 -39.4 178 -26.6 242 -16.9 306 -10.5 370 -4.1 434 2.3 498 8.751 -70.0 115 -39.2 179 -26.4 243 -16.8 307 -10.4 371 -4.0 435 2.4 499 8.852 -69.5 116 -39.0 180 -26.2 244 -16.7 308 -10.3 372 -3.9 436 2.5 500 8.953 -69.0 117 -38.8 181 -26.0 245 -16.6 309 -10.2 373 -3.8 437 2.6 501 9.054 -68.5 118 -38.6 182 -25.8 246 -16.5 310 -10.1 374 -3.7 438 2.7 502 9.155 -68.0 119 -38.4 183 -25.6 247 -16.4 311 -10.0 375 -3.6 439 2.8 503 9.256 -67.5 120 -38.2 184 -25.4 248 -16.3 312 -9.9 376 -3.5 440 2.9 504 9.357 -67.0 121 -38.0 185 -25.2 249 -16.2 313 -9.8 377 -3.4 441 3.0 505 9.458 -66.5 122 -37.8 186 -25.0 250 -16.1 314 -9.7 378 -3.3 442 3.1 506 9.559 -66.0 123 -37.6 187 -24.8 251 -16.0 315 -9.6 379 -3.2 443 3.2 507 9.660 -65.5 124 -37.4 188 -24.6 252 -15.9 316 -9.5 380 -3.1 444 3.3 508 9.761 -65.0 125 -37.2 189 -24.4 253 -15.8 317 -9.4 381 -3.0 445 3.4 509 9.862 -64.5 126 -37.0 190 -24.2 254 -15.7 318 -9.3 382 -2.9 446 3.5 510 9.963 -64.0 127 -36.8 191 -24.0 255 -15.6 319 -9.2 383 -2.8 447 3.6 511 10.0

Page 93: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

88

value Frequency [Hz] Display value Frequency [Hz]Display value Frequency [Hz]Display value Frequency [Hz]Display value Frequency [Hz]Display value Frequency [Hz]Display0 20 20.0 Hz 80 63 63.0 Hz 160 200 200 Hz 240 630 630 Hz 320 2000 2.00 kHz 400 6300 6.30 kHz1 20.3 20.3 Hz 81 64 64.0 Hz 161 203 203 Hz 241 642 642 Hz 321 2030 2.03 kHz 401 6420 6.42 kHz2 20.5 20.5 Hz 82 65 65.0 Hz 162 205 205 Hz 242 655 655 Hz 322 2050 2.05 kHz 402 6550 6.55 kHz3 20.7 20.7 Hz 83 67 67.0 Hz 163 207 207 Hz 243 667 667 Hz 323 2080 2.08 kHz 403 6670 6.67 kHz4 21 21.0 Hz 84 68 68.0 Hz 164 210 210 Hz 244 680 680 Hz 324 2100 2.10 kHz 404 6800 6.80 kHz5 21.3 21.3 Hz 85 68.5 68.5 Hz 165 213 213 Hz 245 687 687 Hz 325 2140 2.14 kHz 405 6880 6.88 kHz6 21.5 21.5 Hz 86 69 69.0 Hz 166 217 217 Hz 246 695 695 Hz 326 2170 2.17 kHz 406 6950 6.95 kHz7 21.7 21.7 Hz 87 70 70.0 Hz 167 220 220 Hz 247 703 703 Hz 327 2200 2.20 kHz 407 7030 7.03 kHz8 22 22.0 Hz 88 71 71.0 Hz 168 224 224 Hz 248 710 710 Hz 328 2240 2.24 kHz 408 7100 7.10 kHz9 22.5 22.5 Hz 89 72 72.0 Hz 169 228 228 Hz 249 722 722 Hz 329 2280 2.28 kHz 409 7220 7.22 kHz

10 23 23.0 Hz 90 73 73.0 Hz 170 232 232 Hz 250 735 735 Hz 330 2320 2.32 kHz 410 7350 7.35 kHz11 23.5 23.5 Hz 91 75 75.0 Hz 171 236 236 Hz 251 747 747 Hz 331 2360 2.36 kHz 411 7470 7.47 kHz12 24 24.0 Hz 92 76 76.0 Hz 172 240 240 Hz 252 760 760 Hz 332 2400 2.40 kHz 412 7600 7.60 kHz13 24.2 24.2 Hz 93 77 77.0 Hz 173 242 242 Hz 253 770 770 Hz 333 2430 2.43 kHz 413 7700 7.70 kHz14 24.5 24.5 Hz 94 78 78.0 Hz 174 245 245 Hz 254 780 780 Hz 334 2450 2.45 kHz 414 7800 7.80 kHz15 24.7 24.7 Hz 95 79 79.0 Hz 175 247 247 Hz 255 790 790 Hz 335 2470 2.47 kHz 415 7900 7.90 kHz16 25 25.0 Hz 96 80 80.0 Hz 176 250 250 Hz 256 800 800 Hz 336 2500 2.50 kHz 416 8000 8.00 kHz17 25.5 25.5 Hz 97 81 81.0 Hz 177 255 255 Hz 257 812 812 Hz 337 2550 2.55 kHz 417 8120 8.12 kHz18 26 26.0 Hz 98 82 82.0 Hz 178 260 260 Hz 258 825 825 Hz 338 2600 2.60 kHz 418 8250 8.25 kHz19 26.5 26.5 Hz 99 83 83.0 Hz 179 265 265 Hz 259 837 837 Hz 339 2650 2.65 kHz 419 8370 8.37 kHz20 27 27.0 Hz 100 85 85.0 Hz 180 270 270 Hz 260 850 850 Hz 340 2700 2.70 kHz 420 8500 8.50 kHz21 27.2 27.2 Hz 101 86 86.0 Hz 181 272 272 Hz 261 862 862 Hz 341 2730 2.73 kHz 421 8620 8.62 kHz22 27.5 27.5 Hz 102 87 87.0 Hz 182 275 275 Hz 262 875 875 Hz 342 2750 2.75 kHz 422 8750 8.75 kHz23 27.7 27.7 Hz 103 89 89.0 Hz 183 278 278 Hz 263 887 887 Hz 343 2770 2.77 kHz 423 8870 8.87 kHz24 28 28.0 Hz 104 90 90.0 Hz 184 280 280 Hz 264 900 900 Hz 344 2800 2.80 kHz 424 9000 9.00 kHz25 28.5 28.5 Hz 105 92 92.0 Hz 185 285 285 Hz 265 915 915 Hz 345 2850 2.85 kHz 425 9150 9.15 kHz26 29 29.0 Hz 106 93 93.0 Hz 186 290 290 Hz 266 930 930 Hz 346 2900 2.90 kHz 426 9300 9.30 kHz27 29.5 29.5 Hz 107 95 95.0 Hz 187 295 295 Hz 267 945 945 Hz 347 2950 2.95 kHz 427 9450 9.45 kHz28 30 30.0 Hz 108 96 96.0 Hz 188 300 300 Hz 268 960 960 Hz 348 3000 3.00 kHz 428 9600 9.60 kHz29 30.5 30.5 Hz 109 97 97.0 Hz 189 304 304 Hz 269 970 970 Hz 349 3040 3.04 kHz 429 9700 9.70 kHz30 31 31.0 Hz 110 98 98.0 Hz 190 307 307 Hz 270 980 980 Hz 350 3070 3.07 kHz 430 9800 9.80 kHz31 31.2 31.2 Hz 111 99 99.0 Hz 191 311 311 Hz 271 990 990 Hz 351 3110 3.11 kHz 431 9900 9.90 kHz32 31.5 31.5 Hz 112 100 100 Hz 192 315 315 Hz 272 1000 1.00 kHz 352 3150 3.15 kHz 432 10000 10.0 kHz33 32 32.0 Hz 113 101 101 Hz 193 321 321 Hz 273 1010 1.01 kHz 353 3210 3.21 kHz 433 10100 10.1 kHz34 33 33.0 Hz 114 102 102 Hz 194 327 327 Hz 274 1020 1.02 kHz 354 3270 3.27 kHz 434 10300 10.3 kHz35 33.5 33.5 Hz 115 103 103 Hz 195 333 333 Hz 275 1030 1.03 kHz 355 3340 3.34 kHz 435 10400 10.4 kHz36 34 34.0 Hz 116 105 105 Hz 196 340 340 Hz 276 1050 1.05 kHz 356 3400 3.40 kHz 436 10500 10.5 kHz37 34.5 34.5 Hz 117 106 106 Hz 197 344 344 Hz 277 1070 1.07 kHz 357 3440 3.44 kHz 437 10700 10.7 kHz38 35 35.0 Hz 118 107 107 Hz 198 347 347 Hz 278 1080 1.08 kHz 358 3470 3.47 kHz 438 10900 10.9 kHz39 35.5 35.5 Hz 119 108 108 Hz 199 351 351 Hz 279 1100 1.10 kHz 359 3510 3.51 kHz 439 11100 11.1 kHz40 36 36.0 Hz 120 110 110 Hz 200 355 355 Hz 280 1120 1.12 kHz 360 3550 3.55 kHz 440 11200 11.2 kHz41 36.5 36.5 Hz 121 112 112 Hz 201 361 361 Hz 281 1140 1.14 kHz 361 3610 3.61 kHz 441 11400 11.4 kHz42 37 37.0 Hz 122 115 115 Hz 202 367 367 Hz 282 1160 1.16 kHz 362 3670 3.67 kHz 442 11600 11.6 kHz43 37.5 37.5 Hz 123 118 118 Hz 203 374 374 Hz 283 1180 1.18 kHz 363 3750 3.75 kHz 443 11800 11.8 kHz44 38 38.0 Hz 124 120 120 Hz 204 380 380 Hz 284 1200 1.20 kHz 364 3800 3.80 kHz 444 12000 12.0 kHz45 38.5 38.5 Hz 125 121 121 Hz 205 385 385 Hz 285 1210 1.21 kHz 365 3850 3.85 kHz 445 12200 12.2 kHz46 39 39.0 Hz 126 122 122 Hz 206 390 390 Hz 286 1220 1.22 kHz 366 3900 3.90 kHz 446 12300 12.3 kHz47 39.5 39.5 Hz 127 123 123 Hz 207 395 395 Hz 287 1240 1.24 kHz 367 3950 3.95 kHz 447 12400 12.4 kHz48 40 40.0 Hz 128 125 125 Hz 208 400 400 Hz 288 1250 1.25 kHz 368 4000 4.00 kHz 448 12500 12.5 kHz49 40.5 40.5 Hz 129 127 127 Hz 209 408 408 Hz 289 1280 1.28 kHz 369 4070 4.07 kHz 449 12800 12.8 kHz50 41 41.0 Hz 130 130 130 Hz 210 415 415 Hz 290 1300 1.30 kHz 370 4150 4.15 kHz 450 13000 13.0 kHz51 42 42.0 Hz 131 133 133 Hz 211 422 422 Hz 291 1330 1.33 kHz 371 4220 4.22 kHz 451 13300 13.3 kHz52 43 43.0 Hz 132 136 136 Hz 212 430 430 Hz 292 1360 1.36 kHz 372 4300 4.30 kHz 452 13600 13.6 kHz53 43.5 43.5 Hz 133 137 137 Hz 213 435 435 Hz 293 1370 1.37 kHz 373 4350 4.35 kHz 453 13700 13.7 kHz54 44 44.0 Hz 134 138 138 Hz 214 440 440 Hz 294 1380 1.38 kHz 374 4400 4.40 kHz 454 13800 13.8 kHz55 44.5 44.5 Hz 135 139 139 Hz 215 445 445 Hz 295 1390 1.39 kHz 375 4450 4.45 kHz 455 13900 13.9 kHz56 45 45.0 Hz 136 140 140 Hz 216 450 450 Hz 296 1400 1.40 kHz 376 4500 4.50 kHz 456 14000 14.0 kHz57 45.5 45.5 Hz 137 143 143 Hz 217 457 457 Hz 297 1430 1.43 kHz 377 4570 4.57 kHz 457 14300 14.3 kHz58 46 46.0 Hz 138 146 146 Hz 218 465 465 Hz 298 1460 1.46 kHz 378 4650 4.65 kHz 458 14600 14.6 kHz59 47 47.0 Hz 139 149 149 Hz 219 472 472 Hz 299 1490 1.49 kHz 379 4730 4.73 kHz 459 14900 14.9 kHz60 48 48.0 Hz 140 152 152 Hz 220 480 480 Hz 300 1520 1.52 kHz 380 4800 4.80 kHz 460 15200 15.2 kHz61 48.5 48.5 Hz 141 154 154 Hz 221 485 485 Hz 301 1540 1.54 kHz 381 4850 4.85 kHz 461 15400 15.4 kHz62 49 49.0 Hz 142 156 156 Hz 222 490 490 Hz 302 1560 1.56 kHz 382 4900 4.90 kHz 462 15600 15.6 kHz63 49.5 49.5 Hz 143 158 158 Hz 223 495 495 Hz 303 1580 1.58 kHz 383 4950 4.95 kHz 463 15800 15.8 kHz64 50 50.0 Hz 144 160 160 Hz 224 500 500 Hz 304 1600 1.60 kHz 384 5000 5.00 kHz 464 16000 16.0 kHz65 50.5 50.5 Hz 145 162 162 Hz 225 507 507 Hz 305 1630 1.63 kHz 385 5080 5.08 kHz 465 16300 16.3 kHz66 51 51.0 Hz 146 165 165 Hz 226 515 515 Hz 306 1650 1.65 kHz 386 5150 5.15 kHz 466 16500 16.5 kHz67 52 52.0 Hz 147 167 167 Hz 227 522 522 Hz 307 1680 1.68 kHz 387 5220 5.22 kHz 467 16800 16.8 kHz68 53 53.0 Hz 148 170 170 Hz 228 530 530 Hz 308 1700 1.70 kHz 388 5300 5.30 kHz 468 17000 17.0 kHz69 53.5 53.5 Hz 149 172 172 Hz 229 538 538 Hz 309 1730 1.73 kHz 389 5380 5.38 kHz 469 17300 17.3 kHz70 54 54.0 Hz 150 175 175 Hz 230 545 545 Hz 310 1750 1.75 kHz 390 5450 5.45 kHz 470 17500 17.5 kHz71 55 55.0 Hz 151 177 177 Hz 231 552 552 Hz 311 1780 1.78 kHz 391 5530 5.53 kHz 471 17800 17.8 kHz72 56 56.0 Hz 152 180 180 Hz 232 560 560 Hz 312 1800 1.80 kHz 392 5600 5.60 kHz 472 18000 18.0 kHz73 57 57.0 Hz 153 183 183 Hz 233 570 570 Hz 313 1830 1.83 kHz 393 5700 5.70 kHz 473 18300 18.3 kHz74 58 58.0 Hz 154 186 186 Hz 234 580 580 Hz 314 1860 1.86 kHz 394 5800 5.80 kHz 474 18600 18.6 kHz75 59 59.0 Hz 155 189 189 Hz 235 590 590 Hz 315 1890 1.89 kHz 395 5900 5.90 kHz 475 18900 18.9 kHz76 60 60.0 Hz 156 192 192 Hz 236 600 600 Hz 316 1920 1.92 kHz 396 6000 6.00 kHz 476 19200 19.2 kHz77 60.5 60.5 Hz 157 194 194 Hz 237 608 608 Hz 317 1940 1.94 kHz 397 6080 6.08 kHz 477 19400 19.4 kHz78 61 61.0 Hz 158 196 196 Hz 238 615 615 Hz 318 1960 1.96 kHz 398 6150 6.15 kHz 478 19600 19.6 kHz79 62 62.0 Hz 159 198 198 Hz 239 623 623 Hz 319 1980 1.98 kHz 399 6230 6.23 kHz 479 19800 19.8 kHz

480 20000 20.0 kHz

Page 94: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

89

# Quality0 0.31 0.352 0.413 0.474 0.555 0.646 0.757 0.878 19 1.2

10 1.411 1.612 1.913 2.214 2.515 316 3.517 418 4.519 520 621 722 8.423 1024 1225 1426 1627 1928 2229 2530 3031 60

# Gain # Gain # Gain0 -18 25 -5.5 50 71 -17.5 26 -5 51 7.52 -17 27 -4.5 52 83 -16.5 28 -4 53 8.54 -16 29 -3.5 54 95 -15.5 30 -3 55 9.56 -15 31 -2.5 56 107 -14.5 32 -2 57 10.58 -14 33 -1.5 58 119 -13.5 34 -1 59 11.5

10 -13 35 -0.5 60 1211 -12.5 36 0 61 12.512 -12 37 0.5 62 1313 -11.5 38 1 63 13.514 -11 39 1.5 64 1415 -10.5 40 2 65 14.516 -10 41 2.5 66 1517 -9.5 42 3 67 15.518 -9 43 3.5 68 1619 -8.5 44 4 69 16.520 -8 45 4.5 70 1721 -7.5 46 5 71 17.522 -7 47 5.5 72 1823 -6.5 48 624 -6 49 6.5

Page 95: ATDM-0604 IP Control Protcol Specifications · Revision History Date Version Revised points 2018/04/27 . Ver1.0.2 . 4.2.35, 4.2.36 Modified” Noise Cancel Attenuation Level ” parameters

90

Value Mic [dB] Line [dB] Aux [dB] Value Mic [dB] Line [dB] Aux [dB]0 20 20 -30 21 41 41 -91 21 21 -29 22 42 42 -82 22 22 -28 23 43 43 -73 23 23 -27 24 44 44 -64 24 24 -26 25 45 45 -55 25 25 -25 26 46 46 -46 26 26 -24 27 47 47 -37 27 27 -23 28 48 48 -28 28 28 -22 29 49 49 -19 29 29 -21 30 50 50 0

10 30 30 -20 31 51 51 111 31 31 -19 32 52 52 212 32 32 -18 33 53 53 313 33 33 -17 34 54 54 414 34 34 -16 35 55 55 515 35 35 -15 36 56 56 616 36 36 -14 37 57 57 717 37 37 -13 38 58 58 818 38 38 -12 39 59 59 919 39 39 -11 40 60 60 1020 40 40 -10

No Item Description Type Value Value Description Remarks

1 p1~p6 Preset1~6

2 i1~i20 4Band EQ Input (4Band EQ)

3 iall All 4Band EQ

4 o1~o20 12Band EQ Output (12Band EQ)

5 oall All 12Band EQ

6 l1~l2 Language file1~2

7 log Logging file

Kind Transfer data kind string