att internal hosr intercell atinhirc 30

Upload: fima-yuda-ektika

Post on 01-Jun-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/9/2019 Att Internal HOSR Intercell ATINHIRC 30

    1/2

    60 A30808-X3247-H40-1-7618

    Performance Measurement Counter InformationSystem

    If the above mentioned relation is not fulfilled, a corresponding counter of NRFLTCH

    is increased instead of UNIHIALC.

    3. A handover of an HSCSD connection is considered as one single handover.

    3.3.4 Intercell Handover Measurements

    Intercell HOs are HOs from one cell to another cell, managed by the same BSC. The

    handovers include TCH-TCH handovers, SDCCH-TCH handovers (i.e. directed retry)

    and SDCCH-SDCCH handovers.

    SDCCH-SDCCH HO is only initiated due to radio link quality reasons, no forced

    SDCCH-SDCCH HO is supported.

    3.3.4.1 ATINHIRC 30: Attempted Internal Handovers, Intercell, per Cause

    Description:

    This measurement gives the number of attempted handovers from the observed cell into

    a different cell managed by the same BSC.

    Different counters distinguish between the handover causes.

    History:

    In BR 5.5 a new counter is established which counts maintenance forced handover.

    Trigger events:

    receipt of a valid INTERCELL HANDOVER CONDITION INDICATION

    (BTS -> BSC)

    Results:

    Counter sequence:

    Parameter Object / Package Meaning

    T10 PKG_BSCT supervises the receipt of anASSIGNMENT COMPLETE message

    TTrau PKG_BTST supervises the datalink connection to theTRAU during connection establishment andhandover

    Tsync PKG_BTST supervises the handling of TRAU frames

    ----------------------------------------------------------------------

    GSM reference: ---

    Latest modification: BR5.5

    Measurement group: BTSMEAS

    Measurement depth: per cell, per handover cause

    ----------------------------------------------------------------------

    Number of counters: 8Counter type: integer

    Unit: none

    Counter no. Attempted internal intercell handovers with cause

    1 uplink quality

    2 downlink quality

  • 8/9/2019 Att Internal HOSR Intercell ATINHIRC 30

    2/2

    A30808-X3247-H40-1-7618 61

    InformationSystem

    Performance Measurement Counter

    Notes:

    1. INTERCELL HANDOVER CONDITION INDICATION messages with empty target

    cell list are not counted

    2. Only BSC controlled handover attempts are considered. Therefore the setting of the

    following configuration parameter impacts the proper working of this measurement:

    If thefirst targetcell in thehandover condition indication message is an external one,

    the HO is considered as MSC-controlled. This applies even if the HO to the firs (ex-

    ternal) cell is not possible and the second cell in the target cell list is an internal cell

    and LOTERCH is set to true.

    3. A handover of an HSCSD connection is considered as one single handover.

    4. The counter maintenance forced handover counts

    forced handovers due to O&M (i.e. due to shutdown of TRX or TCH objects.)

    forced handovers due to preemption

    3.3.4.2 SINTHINT 45: Successful Internal Handovers, Intercell, per Cause

    Description:

    This measurement gives the number of successful handovers from the observed cell

    into a different cell managed by the same BSC.

    Different counters distinguish between the handover causes.

    History:

    In BR 5.5 a new counter is established which counts maintenance forced handover.

    Trigger events:

    receipt of a valid HANDOVER COMPLETE (MS -> BSC)

    Results:

    3 uplink strength

    4 downlink strength

    5 distance

    6 better cell (power budget related to the neighbourcell)

    7 directed retry8 maintenance forced handover

    Parameter Object / Package Meaning required value

    LOTERCH HAND enables/disables TRUE

    BSC controlled

    intercell handovers

    ----------------------------------------------------------------------GSM reference: ---

    Latest modification: BR5.5

    Measurement group: BTSMEAS

    Measurement depth: per cell, per handover cause

    ----------------------------------------------------------------------

    Number of counters: 8

    Counter type: integer

    Unit: none