australian sports commission ais - hpc hpc sssm...
TRANSCRIPT
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
14/02/2017 11:42:50 AM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A001
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
COVER & DRAWING INDEX10.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
AUSTRALIAN SPORTS COMMISSIONAIS - HPC
HPC SSSM BUILDING PACKAGE 1 WORKS23-15844
23-15844
HPC SSSM BUILDING PACKAGE 1 WORKS
DRAWING INDEX - WORKS 1 & 2
PROJECTNo. SHEET TITLE
6.1 WORKSHOP ARCH - WORKS 1 & 223-15844 19-A001 COVER & DRAWING INDEX23-15844 19-A100 SITE PLAN & SECTIONS23-15844 19-A101 SITE DETAIL PLANS23-15844 19-A110 SITE EST & CONSTRUCTION MGMT PLAN23-15844 19-A210 DEMOLITION ELEVATION23-15844 19-A220 FLOOR PLAN23-15844 19-A270 ROOF PLAN23-15844 19-A300 ELEVATIONS23-15844 19-A400 SECTIONS23-15844 19-A450 SECTION DETAILS - SHEET 123-15844 19-A451 SECTION DETAILS - SHEET 223-15844 19-A500 INTERNAL ELEVATIONS - WORKSHOP 1 - 19A10023-15844 19-A560 INTERNAL ELEVATIONS - WORKSHOP 4 - 19A10423-15844 19-A800 DOOR ELEVATION & SPECIFICATIONS23-15844 19-A810 WINDOW ELEVATIONS & SPECIFICATIONS23-15844 19-A950 3D PERSPECTIVES
8.1 WORKSHOP ELECTRICAL23-15844 19-E001 SPECIFICATION & LEGEND23-15844 19-E200 POWER & COMMS LEVEL A & LOWER GROUND
9.1 WORKSHOP HYDRAULIC23-15844 19-H001 LEGEND & GENERAL NOTES23-15844 19-H400 GENERAL ARRANGEMENT
UP
UP
HPC-SSSMLOCATION OF WORKS
LEGEND
EXISTING BUILDINGS
ROADS
BLOCK 26, SECTION 8
SPORTING FIELDS
10. AQUATIC & FITNESS CENTRE
14. CONFERENCE CENTRE (STF)13. BASKETBALL & NETBALL CENTRE
16. ASC RESIDENCES
12. GYMNASTICS CENTRE
07. ARENA
AIS BUILDING NO.01. GIO STADIUM CANBERRA02. ATHLETIC TRACK CHANGE BLOCK06. CHILDCARE CENTRE
08. TENNIS COURTS
11. MULTI-PURPOSE HALL
15. SOCCER FIELDS
34. HIGH PERFORMANCE CENTRE
19. HIGH PERFORMANCE CENTRE - SSSM BLD
17. CORPORATE SERVICES CENTRE
25. SPORTS VISITORS CENTRE
31. SWIM & RECOVERY CENTRE
18. SPINE BUILDING
27. FFA FOOTBALL CENTRE
AIS BUILDING NO.
22. ATHLETICS TRACK GRANDSTAND
20. JUNIOR RESIDENCES21. LOGISTICS COMPLEX
24. MULTI-PURPOSE CHANGEROOM & FIELDS
26. HORTICULTURE CENTRE
28. MERCHANDISING WAREHOUSE30. ASC ADMINISTRATION BUILDING
35. AIS RESIDENCES
LOCATION OF WORKS
SSSM HALL
EXISTING LEVEL B WORKSHOP
EXISTING LGWORKSHOP 6
EXISTING LGWORKSHOP 5
LOCATION OF WORKS
EXISTING SSSMBUILDING EXTENSION
EXISTING SSSM HALLFACADE & SLIDINGDOORS
THROWINGFIELDS M ULTI-PURPOSE
FIELDS
OUTDOORSYNTHETIC
FIELD
ACTEWSWITCHINGSTATION
MASTERMAN STREET
LEVE
RRIER
STRE
ETBRAY
BROO
KE ST
REET
BATTYE STREET
07
10
12
13
14
16
1718
1925
31
34
PODIUM WAY
GUNGAHLIN DRIVE
27
MASTE
RMAN
STREE
TGIO STADIUM
ATHLETICSTRACK
3520
11
0824
SOCCERFIELD
26
01
02
22
1315
SOCCERFIELD
15
2409
06
21
2830
BLOCK 26, SECTION 8ZONE CFZBLOCK AREA: 387014m²Special Requirements applyunder N.C.P.
BLOCK 6,SECTION 24
BLOCK 7,SECTION 46
BLOCK 28,SECTION 8
BLOCK 37,SECTION 8
BLOCK 37,SECTION 8
FF
EE
DD
CC
B
A
X3.6X0X3 X9.6 X15.6 X21.6 X27.6X30 X36 X42 X48 X54 X60 X66
XX1
XX1
XX5
XX5
XX2
XX2 XX3
XX3 XX4
XX4
19A34 19A31
WORKSHOP 219A36 19A104
19A37
19A35WORKSHOP 3 WORKSHOP 4
WORKSHOP 5
WORKSHOP 6
19A105
19A92METALSTORE
19A93
LOWER GROUNDEXISTINGWORKSHOPS 5 & 6
Sim2
19-A101
LINK TO
MAINRECEPTION
SSSM HALL
LOCATION OF WORKS
ACCESS ROAD
MAIN ENTRY
STAFF ENTRY
BUILDING 34
BUILDING 19HIGH PERFORMANCE CENTRESSSM BUILDING
LEVEL A EXISTINGWORKSHOPS 2,3 & 4
PIT 4
319-A100
Sim__________
319-A100
Sim__________
419-A100
Sim__________419-A100
Sim__________
Sim1
19-A110
Sim1
19-A220
Sim1
19-A270
LOCATION OF WORKS
LEGEND
EXISTING LOWERGROUND
EXISTING ACCESSROAD
EXISTING WALKWAY - PAVING
EXISTING TREES
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 5:20:43 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A100
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
SITE PLAN & SECTIONS10.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 20019-A100SITE SECTION LONG - WST-EST4
SCALE 1 : 20019-A100SITE SECTION SHORT - STH-NTH3
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 5:20:43 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A100
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
SITE PLAN & SECTIONS10.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
0
SCALE 1: AT ORIGINAL SIZE
5 10 15 20 25 m
500
N0
SCALE 1: AT ORIGINAL SIZE
50 100 150 200 250m
5000
0
SCALE 1: AT ORIGINAL SIZE
1000 2000 3000 4000 5000 mm
100
0
SCALE 1: AT ORIGINAL SIZE
2000 4000 6000 8000 10000 mm
200
SCALE 1 : 5000WS - LOCATION PLAN1
SCALE 1 : 200WS - LEVEL A SITE LOCATION PLAN2
UP
UP
UP
F
E
D
C
B
X66 XX1 XX5XX2 XX3 XX4
PROPOSEDWORSHOPLOCATION
EXISTINGCARPARK
EXIS
TING
FEN
CE
PRIVATE ACCESS ROAD
RUNNING TRACK
EXISTINGCONCRETERAMP
DN
EXISTING FENCE & GATE
+ -1180 RL(COS)
20m (H)
+
DEMOLISH CONCRETECOVER & WALLS OF EXISTINGBALLAST TANKS. MAKE GOODTO SITE. SITE TO BE FILLEDWITH COMPACTED FILL TOSTRUCTURAL ENGINEER'SDETAILS.
EXISTING CONCRETELANDINGS, FIRST STEP/PLINTH& CONCRETE PATH TO BEDEMOLISHED. EXISTING STEELSTAIRCASE TO BE REMOVED &RELOCATED.
EXISTING RUNNING TRACK TO BEDEMOLISHED. MAKE GOOD TOAREA. SITE TO BE FILLED WITHCOMPACTED FILL TOSTRUCTURAL ENGINEER'SDETAILS.
STEEL MESH FENCE &GATE TO BE REMOVED &RELOCATED.
STEEL MESH FENCE TO BEREMOVED & REINSTATEDAFTER CONSTRUCTION.
EXISTING FENCE
BALLASTTANK 1
BALLASTTANK 2
CONCRETE TRIM.
RUNNING TRACK
CONCRETE
CONCRETE TRIM.
+ -100 RL(COS)
+ -100mm RL (COS)
+ 0 RL (APPROX)
+ -1000mm RL
+ -600mm RL
TWO REDUNDANT STORMWATERPITS (UNDER STAIRS) &ASSOCIATED PIPEWORK ON THESITE IS TO BE DEMOLISHED ANDBE FILLED WITH COMPACTEDFILL. REFER TO HYDRAULICDRAWINGS FOR DETAILS.
COS
1045
1
PROTECT TREES DURINGCONSTRUCTIONPROVIDE OPENING FOR
NEW DOOR.
MECH-ACU
WORKSHOP 419A104
WORKSHOP 319A36
EQ.22
WB.07
EQ.32
EXISTING EQUIPMENTHIGHLIGHTED IN BLUE ARETO BE RELOCATED TO ALOCATION DETERMINED BYTHE CLIENT.
DEMOLISH DOOR FORNEW OPENING.
+ -80 RL(COS)
+ 0 RL
+ -1180 RL(COS)
+ 0 RL
F
E
D
C
B
XX1 XX5XX2 XX3 XX4
EXISTINGCARPARK
PRIVATE ACCESS ROAD
RUNNING TRACK
DN
+0 RL
20m (H)
+
REINSTATE FENCE.
MASTIC JOINT CONNECTION BETWEENNEW PATH & EXISTING SLOPEDWALKWAY. LEVELLING CONCRETESCREED ON SLOPED WALKWAY TOMEET PATH AT TOP AS REQUIRED. ALLCONCRETE PATHS TO HAVE A BRUSHFINISH & MEET AS/NZS 4586, HB197,AS4654 & STANDARDS AUSTRALIA FORSLIP RESISTANCE.
NEW CONCRETE PATHCC-3
MAKE GOOD TO AREA. REINSTATEGRASS. GRADE SLOPE EVENLYFROM RUNNING TRACK TOMOWING STRIP CC-5.
REINSTATE FENCE & GATE TO SUITNEW LOCATION & LENGTH.
CLEAN EXISTING CAR PARKAFTER WORKS
RELOCATE STEEL STAIRCASE WITH NEWCONCRETE LANDINGS & PLINTH TOSTRUCTURAL ENGINEER'S DETAILS. TWOSTEEL COLUMNS (COL-4) & REBARS FIXEDINTO THE EXISTING LEVEL B SLAB ARE TOSUPPORT THE RELOCATED STEELSTAIRCASE. REFER TO STRUCTURALENGINEER'S DETAILS.
CC-5
DP-1
REMOVE TREE PROTECTIONAFTER WORKS
NEW CONCRETETRIM TO MATCHEXISTING
+ -1180mm RL
+ 0 RL
+ 0 RL (APPROX)
+ -1000mm RL
+ -600mm RL
NEW CONCRETE SPOON DRAIN
9002
4004852
COS5242
EXIS
TING
CUR
B LIN
E
STR-E
COL-4
COL-4CC-6
RSH
CC-4
1% FALL
CLEAN RUNNING TRACKAFTER WORKS.
FALL
CLEAN EXISTINGFACADE & DOORSAFTER WORKS
CLEAN EXISTINGSSSM WORKSHOPEXTENSION AFTERWORKS
UP
NEW CONCRETE PATH TOSTRUCTURAL ENGINEER'SDETAILS.
LEGEND
DEMOLISHRELOCATEREMAINNOT IN SCOPE
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
LEGEND
RELOCATEDNEWEXISTING
NOT IN SCOPE
THESE DRAWINGS INCLUDE COLOURED INFORMATION. IFYOU HAVE A BLACK AND WHITE COPY YOU DO NOT HAVETHE INFORMATION. THIS NOTE IS COLOURED IN RED.
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 6:24:08 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A101
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
SITE DETAIL PLANS10.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 10019-801DEMO DETAIL PLAN1
SCALE 1 : 10019-801PROPOSED SITE DETAIL PLAN2
0
SCALE 1: AT ORIGINAL SIZE
1000 2000 3000 4000 5000 mm
100
N
KEYNOTES & FFE SCHEDULE
KEYNOTE DESCRIPTIONCC-3 CONCRETE - CONCRETE EXTERNAL PATH-BRUSH FINISH WITH
EXPANSION JOINTS - TO ENGINEER'S DESIGNCC-4 CONCRETE - CONCRETE LANDING & STEP - TO ENGINEER'S DESIGNCC-5 CONCRETE - CONCRETE MOWING STRIP/SPOON DRAIN - 600mm
WIDTHCC-6 CONCRETE - REINFORCED CONCRETE LANDING TO TOP OF
RELOCATED STAIRS - TO ENGINEER'S DESIGNCOL-4 STEEL 152x6 CHS COLUMN. REFER STRUCTURAL DWGS.DP-1 LYSAGHT COLORBOND DOWNPIPE WITH RAINWATER HEAD-TO
MATCH EXISTING SSSM BUILDING DOWNPIPES.REFER TOHYDRAULIC ENGINEER'S DWGS FOR ALL DETAILS.
EQ.22 EXISTING CARBATEK TABLE SAWEQ.32 EXISTING RUSSIAN MILLF4 EXTERNAL LUMINAIREMECH-ACU EXISTING A/C CONDENSORRSH LYSAGHT TRIMDEK COLORBOND ROOF SHEETSSTR-E EXISTING STEEL STAIRCASE - REFER TO STRUCTURAL DRAWINGS
FOR DETAILSWB.07 EXISTING STEEL WORKBENCH
UP
F
E
D
C
B
X66 XX1 XX5XX2 XX3 XX4
EXISTINGWORKSHOPEXTENSION
PROPOSEDWORSHOPLOCATIONGROSS FLOORAREA : 116m2
NEW ACCESS ROAD(PREV. CAR PARKING)
EXISTING FENCE
EXIS
TING
FEN
CE
EXISTING CARPARK
PRIVATE ACCESS ROAD
TO MASTERMANSTREET
RUNNING TRACK
EXISTINGCONCRETERAMP
DN
EXISTING FENCE
SSSMBUILDING
20m (H)20m (H)
VEHI
CULA
RSI
TE A
CCES
S
SITE ACCESS
WASTESTORAGE
AREA
MATERIALSSTORAGE
AREA
CURRENTLY THISPARKING AREA IS VOIDOF LINEMARKING.SIGNAGE TO INDICATEPARKING ONLY ON THISSIDE DURINGCONSTRUCTION.
7900
1089
4
CLEAR ZONE FORTURNING CIRCLE
DN S3
S3
USE EXISTING FENCE
4600 3300
3000
680
5501500
+
+TREES TO BEPROTECTED DURINGCONSTRUCTION
TEMPORARY RAMPOVER CURB FORVEHICLE ACCESS
WORK SITEENTRY
FENCE TO PROTECTRUNNING TRACK. ENSURERUNNING TRACK IS NOTDAMAGED DURINGCONSTRUCTION
1800mm HIGH TEMPORARYCYCLONE CHAIN MESH FENCING
LEGEND
SILT FENCING
ROADS
PARKING
LANDSCAPE, TREES
S3 AS1319 COMPLIANT SITE SIGNAGE
LOCATION OF WORKS
ALL WORK TO CONFORM TO BCA, ACT ENVIRONMENTPROTECTION AUTHORITY, ENVIRONMENT PROTECTIONGUIDELINES FOR CONSTRUCTION & LANDDEVELOPMENT IN THE ACT.ALL BUILDING WASTE IS TO BE STORED ON THE SITE INSUITABLE RECEPTABLES AND COLLECTEDREGULARLY. CONTRACTORS ARE TO TAKEREASONABLE STEPS TO ENSURE THAT WASTE,PARTICULARLY WIND BORNE LITTER DOES NOTAFFECT ADJOINING LAND.CONTRACTORS TO ESTABLISH BOUNDARY LOCATIONSBEFORE COMMENCING ANY WORK.THE CONTRACTOR IS RESPONSIBLE FOR SITEESTABLISHMENT & CONSTRUCTION MANAGEMENT.
GENERAL NOTE
1.
2.
3.
4.
5.
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 6:24:22 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A110
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
SITE EST & CONSTRUCTION MGMT PLAN17.08.16
D. BELL*
JL JL* DB*
ARCHITECTURE
0ISSUE FOR TENDER0 10.02.17
FOR TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 10019-801
SEDIEMENT & EROSION CONTROLPLAN1
0
SCALE 1: AT ORIGINAL SIZE
1000 2000 3000 4000 5000 mm
100
N
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
E
D C
RLWSH ROOF - LEVEL B
618.205 m
RLLOWER GROUND - WORKSHOP
610.280 m
RLPARAPET- LEVEL B
619.742 m
DEMOLISH 2 x HALFEXISTING CFCS PANELS& INTENAL WALL LININGFOR A NEW DOOR.MAKE GOOD TO FLOOR,WALL & WINDOWABOVE.
F5
DEMOLISH BALLASTTANKS. REFER TODEMOLITION NOTES ONDWG 19-101.
WA-E
319-A800
EXISTING CFCPANELS FORDEMOLITION
HOIST DOOR
2 x EXISTING SHS COLUMNSBEYOND
EXISTING STEELTOP HATS BEYOND
EXISTING GLAZEDPANELS TOREMAIN. REFERDWG 19-A500 FORDETAILS.
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
XX1 XX2
EXISTING PVC PIPING FROMWORKSHOP 4 - 19A104 TO BEREMOVED. MAKE GOOD TO WALL.
EXISTING A/C CONDENSOR UNITS &ASSOCIATED CONDUITS TO BEREMOVED & RELOCATED. REFERMECHANICAL DWGS FOR DETAILS.
DOOR TO BE DEMOLISHED.ADJACENT COLORBOND WALL TOREMAIN. MAKE GOOD TO OPENING.
EXISTING 2 X PVC PIPING.REFER HYDRAULIC DWGS FORDETAILS.
EXISTING FIRE SPRINKLER LINE TOEXTEND INTO NEW WORKSHOP.REFER HYDRAULICS DWGS FORDETAILS.
CONCRETE LANDING FOR STAIRSTO BE DEMOLISHED. CUT BACK TOALIGN WITH LEVEL B FLOOR SLAB.
EXISTING WHITE SYRENE INSULATION& CONCRETE SLAB EXTENDSAPPROX. 100mm FROM FACE OFEXISTING COLORBOND FACADE.CONCRETE TO BE CUT BACK IN LINEWITH EDGE BEAM & HIDDEN FROMVIEW WITH A NEW VERTICAL FIRESEPARATION PANEL (WA-04).
EXISTING DOWNPIPE (DP-E) FROMSSSM ROOF TO BE REDIRECTEDTHROUGH NEW WORKSHOP. REFERHYDRAULICS DWGS FOR DETAILS.
DOOR TO BE DEMOLISHED.MAKE GOOD TO WALL.
29B
137A
TOP C FCPANEL TO REMAIN. ALLOTHER PANELS TO BEDEMOLISHED.
DP-E
MECH-ACU
MECH-ACU
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
XX1
RLWSH ROOF - LEVEL B
618.205 m
XX5XX2
119-A810
XX3 XX4
WIRE MESH FENCE &GATE TO BE REMOVED& RETAINED.
STEEL STAIRS & RAILINGS TOBE REMOVED FORRELOCATION. THE STEELSHELF FIXED TO TOP OFRAILING IS TO BE DEMOLISHED.
EXTERNAL LIGHTING (F6) TOBE DEMOLISHED. REFER TOELECTRICAL DWGS FORDEMOLITION DETAILS.
CCTV CAMERA TO BEREMOVED & REINSTATEDFOLLOWING WORKS. REFERELECTRICAL DWGS FORDETAILS.
CCTV
CONDUITS (ELECT-CDT) TOBE DEMOLISHED. REFERTO ELECTRICAL DWGSFOR DETAILS.
ELECT-CDT ELECT-CDT
F6
F6 MECH-CAS
PROTECT FLOODLIGHT (F5) &ASSOCIATED WIRING DURINGCONSTRUCTION.
F5
WA-E
WA-10137A
FC FACIA FOR DEMOLITION.
EXISTING CFC PANELS FORDEMOLITION
THESE DRAWINGS INCLUDE COLOURED INFORMATION. IFYOU HAVE A BLACK AND WHITE COPY YOU DO NOT HAVETHE INFORMATION. THIS NOTE IS COLOURED IN RED.
LEGEND
DEMOLISHRELOCATEREMAIN
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
1 : 50
13/02/2017 6:27:17 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A210
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
DEMOLITION ELEVATION10.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 5019-A220WSH - DEMO EAST ELEVATION3
SCALE 1 : 50DEMO SOUTH EL CORNER DETAIL1
SCALE 1 : 5019-A220DEMO SOUTH ELEVATION2
0
SCALE 1: AT ORIGINAL SIZE
500 1000 1500 2000 2500 mm
50
KEYNOTES & FFE SCHEDULE
KEYNOTE DESCRIPTIONCCTV CCTV CAMERA TO BE REMOVED & REINSTATED WITH NEW
CABLINGDP-E EXISTING 150 DIA DOWNPIPEELECT-CDT EXISTING EXTERNAL ELECTRICAL CONDUITSF5 EXISTING EXTERNAL FLOOD LIGHT LUMINAIREF6 EXISTING EXTERNAL BATTEN LIGHTINGMECH-ACU EXISTING A/C CONDENSORMECH-CAS EXISTING EXTERNAL COMPRESSED AIR SERVICE LINE- LOWER
LEVEL TO LEVEL B - REFER TO MECHANICAL DRAWINGSWA-10 EXISTING CHAIN MESH FENCINGWA-E EXISTING COLORBOND CUSTOM ORB CLAD TIMBER STUD
FRAMED EXTERNAL WALL
UP
F
E
D
X66 XX1 XX5XX2 XX3 XX4
19-A560D B
C
A
19-A2103
19-A210
2
19-A3001
19-A300
2
A19-A400
__________
A19-A400
__________
B19-A400
__________
B19-A400
__________
EQ.50
LOWER GROUNDWORKSHOP
NEW CONCRETE STAIRS& LANDING (CC-4) FORRELOCATED STEELSTAIRCASE. REFERSTRUCTURALENGINEER'S DETAILS.
151A
150A
COS13548
612
D151
A
2700
370
D150
A
1061
3927
COS
110
2526 665OPENING & LINEMARKING
1200 8725184
205
W1
W2
LN-FD
EXTERNAL LIGHTING (F4)OVER DOOR 150A
NOSNOS
CC-3
F4
GRATED LINEAR FLOORDRAIN TO COVER DOOROPENINGS. ENSURETHRESHOLD OF DOOR150A COMPLIES WITHAS1428.1. GRADECONCRETE PATH AWAYFROM BUILDING.
SKT-2
LINE OF MULLION ON WA-09
COL-SC2
WA-05
LINE OF EXISTING BRICKRETAINING WALL (BRK-E) BELOW.SCREED TOP OF WALL TO MATCHLEVEL OF FLOOR SLAB. FS -EPFINISH TO MATCH.
EXTERNAL PATH
COL-SC2 WA-E BRK-ESKT-2
SKT-2
SKT-2
WA-G
8670
SKT-2
WA-01
WA-01
19-A500
2
19-A500 319-A500
4
19-A5005
FHRFEWA-E WA-G FE
106.76 m²WORKSHOP 1
19A100
C LC L18
5464
COL-SC1
ALL COLUMNS (COL-SC1) TOALIGN WITH EXISTING LEVEL BWORKSHOP COLUMNS
COL-SC1 COL-SC1WA-01
ALL NEW OPENINGS WITHSS WALL GUARDS (WA-G)
COL-SC2
1% FALL
W1118701178
FS-LMAL
IGN
WORKSHOP 319A36
WB.09
FS-EP
NEW WALL WA-03 & DOOR 154A
+ 0 RL
+ 0 RL + 0 RL
+ 0 RL
WA-03154A
NEW 9mm FC LININGS,ACOUSTIC INSULATION &SKIRTINGS SK-02 ON ALLWALLS IN WORKSHOP 4
WORKSHOP 4
19.09 m²19A104
CONCRETE SCREED TO MATCHLEVEL OF WORKSHOP 1 & 3FLOOR SLABS (0 RL). EPOXYFINISH (FS-EP) AS SPECIFIED.
NOTE: ONE STEP AT DOORTHRESHOLD. CONTRACTORTO PROVIDE DOOR TO SUITWIDTH BETWEEN EXISTINGWALL & COLUMN. PROVIDEA CAUTION SIGN "STEP" ONBOTH SIDES OF DOOR.
NEW WALL IN-FILL(WA-05) TOMATCH EXISTING
2865 2331 3596 3596 3593
SSSM HALL19A37
FS-EP
3455
LINE
MARK
ING
1100
3919
93
81512922D154A
831 COS771135
EQ.34
EQ.33
DP-1
DP-1
OUTSIDE OF STAIRS TO ALIGNWITH LEVEL B WORKSHOPFACADE.
0 RL +
EXISTING & NEW BUILDINGFACADES TO ALIGN
CC-4HR-E
CC-5
ALIG
NAL
IGN
WA-10
WA-E1
SKT-2
SKT-2
SKT-2
SKT-2
PIT 4
PIT 4
PIT
4
918 3169
313
2617
UP
D19-A400
Sim__________ D19-A400
Sim__________
C19-A400
Sim__________C19-A400
Sim__________
E19-A400
Sim__________E19-A400
Sim__________
19A105WORKSHOP 5
1361
1000
2477
NOTE:THE FLOOR MAXIMUM LOADINGVARIES ACROSS THE FLOOR SLAB.PROVIDE MAXIMUM FLOOR LOADINGSIGNAGE WITH AREA PLANS INACCORDANCE WITH STRUCTURALDETAILS. SIGN MATERIAL TO MATCHEXISTING.
THESE DRAWINGS INCLUDE COLOURED INFORMATION. IFYOU HAVE A BLACK AND WHITE COPY YOU DO NOT HAVETHE INFORMATION. THIS NOTE IS COLOURED IN RED.
LEGENDRELOCATEDNEWEXISTING
NOT IN SCOPE
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
ROOF NOTES:
ROOF TO BE DESIGNED & CONSTRUCTED INACCORDANCE WITH SECTION J OF NCC (BCA).ROOF PLUMBING TO COMPLY WITH AS3500.ROOF INSTALLER TO ENSURE ALL ROOFPENETRATIONS ARE MADE WATERTIGHT BYTHE USE OF FLASHINGS.FALL PROTECTION SYSTEMS FOR ROOFACCESS MUST BE INSTALLED TO MUSTCOMPLY WITH AS1657.2013, 1891.2009 &488.1997, ALL REVELANT STANDARDS &CODES.METAL ROOFING TO BE INSTALLED INACCORDANCE WITH AS1562.ROOF SAFETY MESH TO COMPY WITH AS/NSZ4389, NSW CODE OF PRACTICE FOR SAFEWORK ON ROOFS, ALL RELEVANT CODES &STANDARDS.
1.
2.3.
4.
5.
6.
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
1 : 50
13/02/2017 6:27:40 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A220
J LUCAS J LUCAS
D BELL*
D. BELL*
FLOOR PLAN10.02.17
J DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 5019-A100WORKSHOP 1 - DETAIL PLAN1
0
SCALE 1: AT ORIGINAL SIZE
500 1000 1500 2000 2500 mm
50
N
KEYNOTES & FFE SCHEDULEKEYNOTE DESCRIPTIONBRK-E EXISTING DOUBLE BRICK RETAINING WALLCC-3 CONCRETE - CONCRETE EXTERNAL PATH-BRUSH FINISH WITH
EXPANSION JOINTS - TO ENGINEER'S DESIGNCC-4 CONCRETE - CONCRETE LANDING & STEP - TO ENGINEER'S DESIGNCC-5 CONCRETE - CONCRETE MOWING STRIP/SPOON DRAIN - 600mm
WIDTHCOL-SC1 STEEL 200UB25 COLUMN. REFER STRUCTURAL DWGS.COL-SC2 STEEL 76x6 SHS COLUMN. REFER STRUCTURAL DWGS.DP-1 LYSAGHT COLORBOND DOWNPIPE WITH RAINWATER HEAD-TO
MATCH EXISTING SSSM BUILDING DOWNPIPES.REFER TOHYDRAULIC ENGINEER'S DWGS FOR ALL DETAILS.
EQ.33 EXISTING VERTICAL BAND SAWEQ.34 EXISTING PRESSEQ.50 NEW VMAX42SRTi AXIS MACHINING CENTREF4 EXTERNAL LUMINAIREFAK FIRST AID KITFE FIRE EXTINGUISHERFHR FIRE HOSE REELFS-EP EXPOXY FLOOR FINISH - HYCHEM SF12FGFS-LM LINEMARKING-ABRASIVE YELLOW NON-SLIP TAPE OR PAINTHR-E EXISTING STEEL HANDRAILLN-FD STORMTECH LINEAR DRAINAGE SYSTEM - HYDRAULIC ENGINEER
TO SPECIFY DIMENSIONSNOS LATHAM 775SB 1428.1-2009 COMPLIANT EDGE SAFETY NOSINGSKT-2 ALUMINIUM SKIRTING-200mmHW1 NEW DOUBLE GLAZED LIDCO 715 SERIES SYSTEM-LEVEL A-SOUTHW2 NEW DOUBLE GLAZED LIDCO 715 SERIES SYSTEM-LEVEL A-EASTWA-01 EXTERNAL WALL - LYSAGHT CUSTOM ORB CLADDING, 35mm STEEL
TOP HATS, PROMINA 60 BOARD, FLETCHER TITANTUFF™ WALLWRAP WITH R2.7 90MM PINK® SONOBATTS® PREMIUM, 92mmSTEEL STUD FRAMING, 9mm CSR CEMINTEL FIBRE CEMENT WALLPANELS.
WA-03 INTERNAL WALL - IN: 9mm FC SHEETING,92mm RONDO STEELSTUDS WITH ACOUSTIC INSULATION,9mm FC SHEETING : OUT
WA-05 INTERNAL WALL - TO INFILL OPENING - LYSAGHT CUSTOM ORBCLADDING, WALL INSULATION (OPTIONAL), 92mm STEEL STUDFRAMING, PLYWOOD, . WALL TO MATCH EXISTING
WA-10 EXISTING CHAIN MESH FENCINGWA-E EXISTING COLORBOND CUSTOM ORB CLAD TIMBER STUD FRAMED
EXTERNAL WALLWA-E1 EXISTING PLYWOOD TIMBER FACED TIMBER STUD INTERNAL WALLWA-G S/S WALL GUARDWB.09 EXISTING STEEL WORK BENCH - TYPE 9
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
THESE DRAWINGS INCLUDE COLOURED INFORMATION. IFYOU HAVE A BLACK AND WHITE COPY YOU DO NOT HAVETHE INFORMATION. THIS NOTE IS COLOURED IN RED.
E
D
C
XX1 XX5XX2 XX3 XX4
19B20
19B19
19B23
EXISTING LEVEL B WORKSHOP19B21
150B
RSH
DP-1
DP-2DP-1
DP-2GU
STR-E
CC-4
COL-4
CC-6
HR-E
FALL PROTECTION SYSTEMS TO BEDESIGNED & INSTALLED BYTREDRITE. CLIENT TO CONFIRM.THE SYSTEM MUST COMPLY WITHAS1657.2013, 1891.2009 & 488.1997,ALL REVELANT STANDARDS &CODES.
EXISTING DOWNPIPE (DP-E) TO BEREDIRECTED THROUGH BUILDINGTO NEW DOWNPIPE. REFERHYDRAULIC DRAWINGS FORDETAILS. ALL ROOF PENETRATIONSTO HAVE DEKTITE FLASHINGS.
DP-E
ALIG
N
HOIST DOOR
FIX NEW WORKSHOP 1 RAFTERS TOEXISTING COLUMNS IN LEVEL BWORKSHOP 19B21. REFER TOSECTION & STRUCTURAL DETAILS
ALIGN
ALIGN NEW EXTERNALFACE OF WALL WA-1 WITHCORNER OF EXISTINGFACADE
COL-4
WA-10
ALIG
N
ALIG
N
ALIG
N
ALIG
N
ALIG
NOUTSIDE OF STAIRS TOALIGN WITH LEVEL BWORKSHOP FACADE.
NEW WORKSHOP 1
UP
COS
381
COS
4876
D150
B10
61CO
S37
87
SHS-E
SHS-E
COL-EXCOL-EXCOL-EXCOL-EXCOL-EX
SHS-E
SHS-E
SHS-ESHS-E
COL-EXCOL-EXCOL-EXCOL-EX
CROSS BRACING
CROSS BRACING
NEW FIRE DOOR 150B TO BEINSTALLED BETWEEN THE EXISTINGSHS COLUMN (SHS-E) & EXISTINGWALL TOP HAT. SEE DEMOELEVATION FOR DETAILS.
NEW CONCRETE LANDING TO BEDOWELLED INTO THE EXISTINGLEVEL B CONCRETE FLOOR SLAB INACCORDANCE WITH STRUCTURALENGINEER'S DETAILS.
NEW CONCRETE LANDING &PLINTH TO BE BUILT ACCORDINGTO STRUCTURAL ENGINEER'SDETAILS.
LEGENDRELOCATEDNEWEXISTING
NOT IN SCOPE
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
1 : 50
13/02/2017 6:27:58 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A270
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
ROOF PLAN10.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURE
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
SSSM BUILDING WORKS0
SCALE 1: AT ORIGINAL SIZE
1000 2000 3000 4000 5000 mm
100
N
SCALE 1 : 5019-A100ROOF PLAN1
KEYNOTES & FFE SCHEDULE
KEYNOTE DESCRIPTIONCC-4 CONCRETE - CONCRETE LANDING & STEP - TO
ENGINEER'S DESIGNCC-6 CONCRETE - REINFORCED CONCRETE LANDING TO
TOP OF RELOCATED STAIRS - TO ENGINEER'SDESIGN
COL-4 STEEL 152x6 CHS COLUMN. REFER STRUCTURALDWGS.
COL-EX EXISTING 250UB37 STEEL COLUMNDP-1 LYSAGHT COLORBOND DOWNPIPE WITH
RAINWATER HEAD-TO MATCH EXISTING SSSMBUILDING DOWNPIPES.REFER TO HYDRAULICENGINEER'S DWGS FOR ALL DETAILS.
DP-2 LYSAGHT COLORBOND OVER FLOW PIPE-TOMATCH DOWNPIPE. REFER TO HYDRAULICENGINEER'S DWGS FOR ALL DETAILS.
DP-E EXISTING 150 DIA DOWNPIPEF4 EXTERNAL LUMINAIREGU COLORBOND BOX GUTTER - BOX GUTTER 600mm
WIDE 150mm MIN DEPTHHR-E EXISTING STEEL HANDRAILRSH LYSAGHT TRIMDEK COLORBOND ROOF SHEETSSHS-E EXISTING 100x5 SHS. REFER STRUCTURAL DWGS.STR-E EXISTING STEEL STAIRCASE - REFER TO
STRUCTURAL DRAWINGS FOR DETAILSWA-10 EXISTING CHAIN MESH FENCING
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
RLLOWER GROUND - WORKSHOP
610.280 m
RLWSH - PARAPET
615.932 m
RLPARAPET- LEVEL B
619.742 m
CC-4
151A 150A
MECH-ACU
W2
F4
MECH-ACU
150B
DP-E
CC-2CC-3
HOIST DOOR
WA-01
NOSNOS
WA-08
DP-1
COL-4
STR-E
Sim2
19-A810
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
RLWSH - PARAPET
615.932 m
119-A810
W1WA-10
DP-1
WA-04
CC-2
WA-01
DP-1
COL-4
HR-E
STR-E
CCTV
MATERIAL: FIBRE CEMENTCOLOUR: WHITE ON WHITE (TO MATCH EXISTING)
COLOUR BOARD/FINISHES
MATERIAL: LYSAGHT COLORBOND KLIP-LOK 406COLOUR: SURFMIST
MATERIAL: LYSAGHT COLORBOND CUSTOM ORB CLADDINGCOLOUR & PROFILE (TO MATCH EXISTING)
COLOUR: DEEP OCEAN (TO MATCH EXISTING)
DOOR LEAFS WINDOW FRAMESEXTERNAL STAIR (STR)STRINGERS & POSTSDOWNPIPES (DP1)OVERFLOW PIPES (DP-2)
MATERIAL: DULUX METALSHIELD ENAMEL PAINT OR SIMILARCOLOUR: DEEP OCEAN COLORBOND B, C24
ROOF SHEETING (RSH)
WALLING (WA-01)
EXTERNAL FACADEPANELS (WA-02)
MATERIAL: DULUX METALSHIELD ENAMEL PAINT OR SIMILARCOLOUR: WHITE ON WHITE (TO MATCH EXISTING)
MATERIAL: COLORBOND SHEET METALCOLOUR: SURFMISTROOF FLASHINGS (RFL)
MATERIAL: HYCHEM EXPOXY ANTI-SLIP FLOOR COATINGOR SIMILAR ANTI SLIP FLOOR PAINT.
COLOUR: N54 BASALT
DOOR FRAMES
FLOOR FINISHES(FS-EP)
MATERIAL: COLORBOND SHEET METAL OR SIMILARCOLOUR: DEEP OCEAN
EXTERNAL LIGHT HOUSINGPARAPET CAPPING
STAIR NOSING(NOS)
MATERIAL: LATHAM 775SB 1428.1-2009 COMPLIANT EDGE SAFETY NOSING
COLOUR: BLUE LRV32.01
MATERIAL: ALUCOBOND PLUS COMPOSITECOLOUR: WHITE 16-101 (TO MATCH EXISTING)
INTERNAL SPANDRALPANELS (WA-04) & (WA-07)
MATERIAL: FIBRE CEMENTCOLOUR: WHITE ON WHITE (TO MATCH EXISTING)
EXTERNAL FACADEPANELS (WA-08)
ITEM & KEYNOTE SPECIFICATION & FINISHSAMPLEPROFILE
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 6:28:32 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A300
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
ELEVATIONS10.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 5019-A220WSH - EAST ELEVATION1
SCALE 1 : 5019-A220WSH- SOUTH ELEVATION2
0
SCALE 1: AT ORIGINAL SIZE
500 1000 1500 2000 2500 mm
50
KEYNOTES & FFE SCHEDULE
KEYNOTE DESCRIPTIONCC-2 CONCRETE - CONCRETE PERIMETER HOB-TO BE POURED WITH FLOOR SLAB
- TO ENGINEER'S DESIGNCC-3 CONCRETE - CONCRETE EXTERNAL PATH-BRUSH FINISH WITH EXPANSION
JOINTS - TO ENGINEER'S DESIGNCC-4 CONCRETE - CONCRETE LANDING & STEP - TO ENGINEER'S DESIGNCCTV CCTV CAMERA TO BE REMOVED & REINSTATED WITH NEW CABLINGCOL-4 STEEL 152x6 CHS COLUMN. REFER STRUCTURAL DWGS.DP-1 LYSAGHT COLORBOND DOWNPIPE WITH RAINWATER HEAD-TO MATCH
EXISTING SSSM BUILDING DOWNPIPES.REFER TO HYDRAULIC ENGINEER'SDWGS FOR ALL DETAILS.
DP-E EXISTING 150 DIA DOWNPIPEF4 EXTERNAL LUMINAIREHR-E EXISTING STEEL HANDRAILMECH-ACU EXISTING A/C CONDENSORNOS LATHAM 775SB 1428.1-2009 COMPLIANT EDGE SAFETY NOSINGSTR-E EXISTING STEEL STAIRCASE - REFER TO STRUCTURAL DRAWINGS FOR
DETAILSW1 NEW DOUBLE GLAZED LIDCO 715 SERIES SYSTEM-LEVEL A-SOUTHW2 NEW DOUBLE GLAZED LIDCO 715 SERIES SYSTEM-LEVEL A-EASTWA-01 EXTERNAL WALL - LYSAGHT CUSTOM ORB CLADDING, 35mm STEEL TOP
HATS, PROMINA 60 BOARD, FLETCHER TITANTUFF™ WALL WRAP WITH R2.790MM PINK® SONOBATTS® PREMIUM, 92mm STEEL STUD FRAMING, 9mmCSR CEMINTEL FIBRE CEMENT WALL PANELS.
WA-04 INTERNAL VERTICAL FIRE SEPARATION WALL. IN: 13mm GYPROCK FYRCHEK,16mm GYPROCK FYRCHEK, 35mm TOP HATS FIXED TO EXISTING STUD WALL& PORTAL FRAME, EXISTING INTERNAL LINING :OUT (LEVEL B WORKSHOP) -MIN FRL 90/90/90,
WA-08 EXTERNAL PANELS - EXTERNAL GRADE FC WALL PANELS TO MATCHEXISTING
WA-10 EXISTING CHAIN MESH FENCING
RELOCATED A/C CONDENSERS. ALLOWFOR ALL ASSOCIATED WORK,INCLUDING PIPEWORK, PRESSURETESTING, CABLING AND SUPPORTS
19A93
19B21
EXISTING LEVEL BWORKSHOP
WORKSHOP 6
WORKSHOP 119A100
SimA
19-A450
SimB
19-A450
SimC
19-A450
SimD
19-A450
WA-07
COL-SC2 WA-07
SKT-2
BR-VB1
WA-07
EXISTING LEVEL BWORKSHOP
150A 151A
19A104
19B21
WORKSHOP 4
WORKSHOP 119A100
W2 W1
WA-10
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
19A100WORKSHOP 1
COL-SC1COL-SC1COL-SC1 WA-01
W1
BR-VB1
BR-VB1
151A
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
RLWSH ROOF - LEVEL B
618.205 m
RLLOWER GROUND - WORKSHOP
610.280 m
RLWSH - PARAPET
615.932 m
WA-E
WA-04
RSH
WA-02
FHR
151A
WORKSHOP 1
TO WORKSHOP4
Sim1
19-A451
SimF
19-A451
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
RLLOWER GROUND - WORKSHOP
610.280 m
07LG
19A105
WORKSHOP 5 &CHEMICAL STORE
19B21
EXISTING LEVEL BWORKSHOP
CARPARK
SLOPED WALKWAY
WA-10WA-10
RELOCATED A/C CONDENSERSUNDER STAIRS. ALLOW FOR ALLASSOCIATED WORK, INCLUDINGPIPEWORK, PRESSURE TESTING,CABLING AND SUPPORTS. LEGEND
RELOCATEDNEWEXISTING
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
1 : 50
13/02/2017 6:28:54 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A400
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
SECTIONS10.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 5019-A220SECTION A-AA
SCALE 1 : 5019-A220SECTION B-BB
0
SCALE 1: AT ORIGINAL SIZE
500 1000 1500 2000 2500 mm
50
SCALE 1 : 5019-A220SECTION C-CC
SCALE 1 : 5019-A220SECTION D-DD
SCALE 1 : 5019-A220SECTION E-EE
BUILDING FABRIC & FINISHES SCHEDULE..
KEYNOTE DESCRIPTIONBR-VB1 VERTICAL BRACE-76x3.2CHS. REFER STRUCTURAL DWGS.CC-4 CONCRETE - CONCRETE LANDING & STEP - TO ENGINEER'S
DESIGNCOL-SC1 STEEL 200UB25 COLUMN. REFER STRUCTURAL DWGS.COL-SC2 STEEL 76x6 SHS COLUMN. REFER STRUCTURAL DWGS.FHR FIRE HOSE REELHR-E EXISTING STEEL HANDRAILMECH-ACD AIR CONDITIONING DUCT - REFER TO MECHANICAL
DRAWINGSPU PURLIN-Z10012 @ 1200crs LAPPED 900.MIDSPAN BRIDGING.
REFER STRUCTURAL DWGS..RSH LYSAGHT TRIMDEK COLORBOND ROOF SHEETSSKT-2 ALUMINIUM SKIRTING-200mmHW1 NEW DOUBLE GLAZED LIDCO 715 SERIES SYSTEM-LEVEL
A-SOUTHW2 NEW DOUBLE GLAZED LIDCO 715 SERIES SYSTEM-LEVEL
A-EASTW9 EXISTING SINGLE GLAZED PANELS - PAINTED SURFACE TO
BE REMOVED FROM 6 WINDOWS AS INDICATED ON DRWA400A. THE REMAINING PANELS TO BE RE-PAINTED WHITE.
WA-01 EXTERNAL WALL - LYSAGHT CUSTOM ORB CLADDING, 35mmSTEEL TOP HATS, PROMINA 60 BOARD, FLETCHERTITANTUFF™ WALL WRAP WITH R2.7 90MM PINK®SONOBATTS® PREMIUM, 92mm STEEL STUD FRAMING, 9mmCSR CEMINTEL FIBRE CEMENT WALL PANELS.
WA-02 EXTERNAL WALL - OUT: EXTERIOR GRADE FC WALL PANELSTO MATCH EXISTING, EXISTING LEVEL B WALL :LEVEL BWORKSHOP
WA-04 INTERNAL VERTICAL FIRE SEPARATION WALL. IN: 13mmGYPROCK FYRCHEK, 16mm GYPROCK FYRCHEK, 35mm TOPHATS FIXED TO EXISTING STUD WALL & PORTAL FRAME,EXISTING INTERNAL LINING :OUT (LEVEL B WORKSHOP) - MINFRL 90/90/90,
WA-07 INTERNAL PANELS - 9mm FIBRE CEMENT WALL PANELSWA-10 EXISTING CHAIN MESH FENCINGWA-E EXISTING COLORBOND CUSTOM ORB CLAD TIMBER STUD
FRAMED EXTERNAL WALL
RLLEVEL B
614.960 m
RLWSH - PARAPET
615.932 m
PU
RSH
INS-RRF-SP
RF-SMGU
WD-WS1
OUT:1. LYSAGHT COLORBOND BOX GUTTER WITH
OVERFLOWS. REFER TO HYDRAULICDRAWINGS FOR SIZE & TYPE.
2. FLASHING3. INSULATION3. GUTTER BOARD4. EA & TOP HAT CONNECTIONS TO RAFTER
RA-RB1.IN:
FIXINGS & INSULATION TO BE IN ACCORDANCEWITH MANUFACTURER'S SPECIFICATIONS
GUTTER (GU)
OUT:1. LYSAGHT TRIMDEK COLORBOND ROOF SHEETS(RSH).2. FLETCHER ROOF RACK INSULATION SPACER(RF-SP)3. R3.5 130mm FLETCHER PERMASTOPREFLECTIVE INSULATION (INS-R)3. FLETCHER ROOFSAFE SAFETY MESH (RF-SM)IN:MIN TOTAL R3.7 UPWARDS CONSTRUCTIONFIXINGS TO BE IN ACCORDANCE WITHMANUFACTURER'S SPECIFICATIONS
ROOF
RA-RB1
COL-SC1
OUTSIDE
OUT:1. LYSAGHT CUSTOM ORB CLADDING2. 35mm STEEL BATTENS OR TOPHATS,3. PROMINA 60 BOARD4. FLETCHER TITANTUFF™ WALL WRAP WITH
R2.7 90MM PINK® SONOBATTS® PREMIUM5. STEEL STUD FRAMING6. 9mm CSR CEMINTEL FIBRE CEMENT WALLPANELS.IN:
MIN TOTAL R2.8 THERMAL PERFORMANCE
FIXINGS TO BE IN ACCORDANCE WITHMANUFACTURER'S SPECIFICATIONS
EXTERNAL WALL WA-01
3.00°
RLLEVEL A
611.460 m
CC-1
CC-5
COL-SC1W1
WALL & WINDOW FLASHINGSTO WALL MANUFACTURER'SSPECIFICATIONS
100CC-2
MONLOLITHIC HOB (CC-2) &FLOOR SLAB (CC-1). REFER TOSTRUCTURAL DETAILS.
IN:1. MONOLITHIC CONCRETE SLAB,
FOUNDATION & HOB2. WATERPROOF MEMBRANE.3. R1.0 RIGID INSULATION4. GRAVEL BASE5. COMPACTED FILLOUT:
MIN TOTAL R1.0 DOWNWARDSCONSTRUCTION
REFER TO STRUCTURALDRAWINGS FOR SLAB, SUBGRADE & SUB BASE DETAILS
SLAB & FOUNDATION
IN:1. 600mm WIDE CONCRETE MOWING
STRIP/SPOON DRAIN.3. 10mm JOINTEX MASTIC AT ALL JUNCTIONS4. TERMINATION OF WATERPROOFMEMBRANEOUT:
MOWING STRIP/SPOON DRAIN CC-5
SKT-2
200
EGL
NEW GROUNDLEVELSTO SUIT
NGL
NEW WORKSHOP 1OUTSIDE
WA-01
RLLEVEL A
611.460 m
D
SKT-2
WA-E
BRK-E
CC-1
NEW WORKSHOP 1
OUTSIDE
LOWER GROUND WORKSHOP 5
EXISTING DOUBLE BRICKRETAINING WALL (BRK-E)
SCREED TOP OF BRICK LEVEL WITH NEWSLAB CC-1 EPOXY PAINT TO MATCH NEWSLAB
COL-SC2
RLLEVEL B
614.960 m
D
RLWSH ROOF - LEVEL A
615.396 m
RLWSH - PARAPET
615.932 m
IN:
1. 13mm GYPROCK FYRCHEK2. 16mm GYROCK FYRCHEK,3. 35mm STEEL TOPHATS,4. EXISTING STUD WALL & PORTAL FRAME5. EXISTING INTERNAL LINING
19B21:
MIN FRL 90/90/90 & MIN TOTAL R2.8 THERMALPERFORMANCE. USE FIRE MASTIC FOR ALL SEALS
FIXINGS & FLASHINGS TO BE IN ACCORDANCE WITHMANUFACTURER'S SPECIFICATIONS
SPANDRAL VERTICAL FIRESEPARATION WALL WA.04
PURF-SP
RA-RB1
INS-RRSH
NEW FIRE SPRINKLER LINES.REFER DWG 19-H500.
COL-EX
NEW STEEL RAFTER RA-RB1 TO BE FIXEDTO EXISTING STEEL COLUMN COL-EX.REFER TO STRUCTURAL DRAWINGS FORDETAILS.
50x10 'U' GAL STEELPERIMETER TRIM. SEALWITH FIRE MASTIC.
FC SPANDRAL PANEL(WA-04)
COL-SC2
SEAL JUNCTIONS WITH COLOURBONDSURFMIST STEEL FLASHINGS (RFL) &MASTIC SEALANT TO WALLMANUFACTURER'S DETAILS
EXTERNAL WALL LEVEL BWA-02OUT:1. EXTERIOR GRADE FC WALL PANELS TO
MATCH EXISTING2. EXISTING WALL19B21:
SEAL JUNCTIONS WITHCOLOURBOND SURFMIST STEELFLASHINGS (RFL) & MASTICSEALANT TO WALLMANUFACTURER'S DETAILS
EXISTING LEVEL B WORKSHOP HIGHLEVEL WINDOW
EXISTING LEVEL B WORKSHOP WALL
OUTSIDE
INSIDE
WORKSHOP LEVEL B19B21
LOWERGROUND WORKSHOP 619A93
WA-02
WA-04
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
LEGEND
NEW
EXISTING
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 6:29:19 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A450
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
SECTION DETAILS - SHEET 110.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 1019-A400DETAIL SECTION BA
SCALE 1 : 1019-A400DETAIL SECTION AB
SCALE 1 : 1019-A400DETAIL SECTION CC
SCALE 1 : 1019-A400DETAIL SECTION DD
0
SCALE 1: AT ORIGINAL SIZE
100 200 300 400 500 mm
10
KEYNOTES & FFE SCHEDULE
KEYNOTE DESCRIPTIONBRK-E EXISTING DOUBLE BRICK RETAINING WALLCC-1 CONCRETE - FLOOR SLAB - TO ENGINEER'S DESIGNCC-2 CONCRETE - CONCRETE PERIMETER HOB-TO BE POURED WITH FLOOR SLAB -
TO ENGINEER'S DESIGNCC-5 CONCRETE - CONCRETE MOWING STRIP/SPOON DRAIN - 600mm WIDTHCOL-EX EXISTING 250UB37 STEEL COLUMNCOL-SC1 STEEL 200UB25 COLUMN. REFER STRUCTURAL DWGS.COL-SC2 STEEL 76x6 SHS COLUMN. REFER STRUCTURAL DWGS.FS-EP EXPOXY FLOOR FINISH - HYCHEM SF12FGGU COLORBOND BOX GUTTER - BOX GUTTER 600mm WIDE 150mm MIN DEPTHINS-R R3.5 130mm FLETCHER PERMASTOP REFLECTIVE INSULATION LAID OVER
SAFETY MESH (RF-SM) EXPOSED TO VIEWPU PURLIN-Z10012 @ 1200crs LAPPED 900.MIDSPAN BRIDGING. REFER
STRUCTURAL DWGS..RA-RB1 STEEL RAFTER-200UB25. REFER STRUCTURAL DWGS.RF-SM AS4389 COMPLIANT ROOF SAFETY MESH - FLETCHER ROOFSAFE SAFETY
MESHRF-SP INSULATION SPACER - FLETCHER ROOF RACKRSH LYSAGHT TRIMDEK COLORBOND ROOF SHEETSSKT-2 ALUMINIUM SKIRTING-200mmHW1 NEW DOUBLE GLAZED LIDCO 715 SERIES SYSTEM-LEVEL A-SOUTHWA-01 EXTERNAL WALL - LYSAGHT CUSTOM ORB CLADDING, 35mm STEEL TOP HATS,
PROMINA 60 BOARD, FLETCHER TITANTUFF™ WALL WRAP WITH R2.7 90MMPINK® SONOBATTS® PREMIUM, 92mm STEEL STUD FRAMING, 9mm CSRCEMINTEL FIBRE CEMENT WALL PANELS.
WA-02 EXTERNAL WALL - OUT: EXTERIOR GRADE FC WALL PANELS TO MATCHEXISTING, EXISTING LEVEL B WALL :LEVEL B WORKSHOP
WA-04 INTERNAL VERTICAL FIRE SEPARATION WALL. IN: 13mm GYPROCK FYRCHEK,16mm GYPROCK FYRCHEK, 35mm TOP HATS FIXED TO EXISTING STUD WALL &PORTAL FRAME, EXISTING INTERNAL LINING :OUT (LEVEL B WORKSHOP) - MINFRL 90/90/90,
WA-E EXISTING COLORBOND CUSTOM ORB CLAD TIMBER STUD FRAMED EXTERNALWALL
WD-WS1 WINDOW SUPPORT-150PFC. REFER STRUCTURAL DWGS.
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
XX1
RLWSH - PARAPET
615.932 m
RLWSH - LIGHTING LEVEL A
613.860 m
NEW EXTERNAL GRADE CFCPANEL TO MATCH EXISTING
NEW LYSAGHT COLORBONDSURFMIST STEEL PANEL (RFL)FIXED TO EXISTING FACADE FIXINGSYSTEM IN ACCORDANCE WITHLYSAGHT RECOMMENDATIONS.
NEW FACADE FIXING SYSTEM WITHFLASHINGS TO LYSAGHTRECOMMENDATIONS.
FIX NEW FC PANELS TO THEEXISTING FIXING SYSTEM
FIX NEW EXTERNAL GRADE CFCPANELS TO EXISTING SYSTEM
INS-R
PU
RA-RB2
COL-SC2
EXTERNAL FILM ON GLAZEDPANELS TO BE REMOVED.CLEAN WINDOWS, REAPPLYPAINT TO FRAME & CLEANCONCRETE HOB
REFER TO STRUCTURALDRAWINGS FOR ALL EXISTINGTO NEW CONCRETE FLOORSLAB DETAILS.
WA-07
EXISTING INTERNALSTEEL PORTAL FRAME
SSSM HALL INSIDE
OUTSIDE
EXISTING CONCRETE HOBGENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
LEGEND
NEW
EXISTING
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
XX5
RLWSH - PARAPET
615.932 m
1. LYSAGHT COLORBOND STEEL CAPPING2. LYSAGHT C0LORBOND STEEL (SURFMIST)3. WATERPROOF MEMBRANE4. FLASHING5. STEEL APRON FOR OVER FLOW6. STEEL BATTEN7. CAVITY SPRAY FOAM8. 92mm STEEL STUD FRAMING9. FLETCHER TITANTUFF WALL WRAP10. PROMINA 60 BOARD11. 35mm STEEL TOP HATS12. LYSAGHT CUSTOM ORB CLADDING TO
MATCH EXISTING
FIXINGS & FLASHING TO BE IN ACCORDANCE WITHMANUFACTURER'S SPECIFICATIONS
FIXINGS & FLASHINGSTO BE IN ACCORDANCEWITH WALLMANUFACTURER'SSPECIFICATIONS
1% FALL
LN-FD CC-3CC-1
SKT-2
WA-01
PURF-SPINS-R
RA-RB1
ST-S1
100X10 EA GIRT POSTWELDED TO SC1 COLUMNTYPICAL. REFER TOSTRUCTURAL DRAWINGSFOR ALL STRUCTURALDETAILS
151A
F4
FIXINGS & FLASHINGS TO BE INACCORDANCE WITH WALLMANUFACTURER'SSPECIFICATIONS
10mm JOINTEX
REFER TO ELECTRICALDRAWING FOR ALLLIGHTING DETAILS.
LINEAR FLOOR DRAIN (LN-FD)TO BE INSTALLED INACCORDANCE WITHMANUFACTURER'S DETAILS
INSIDE NEWWORKSHOP
OUTSIDE
OUTSIDE
PARAPET
WA-02
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 6:29:32 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A451
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
SECTION DETAILS - SHEET 210.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 1019-A400DETAIL SECTION FF
KEYNOTES & FFE SCHEDULE
KEYNOTE DESCRIPTIONCC-1 CONCRETE - FLOOR SLAB - TO ENGINEER'S DESIGNCC-3 CONCRETE - CONCRETE EXTERNAL PATH-BRUSH FINISH WITH
EXPANSION JOINTS - TO ENGINEER'S DESIGNCOL-SC2 STEEL 76x6 SHS COLUMN. REFER STRUCTURAL DWGS.F4 EXTERNAL LUMINAIREINS-R R3.5 130mm FLETCHER PERMASTOP REFLECTIVE INSULATION
LAID OVER SAFETY MESH (RF-SM) EXPOSED TO VIEWLN-FD STORMTECH LINEAR DRAINAGE SYSTEM - HYDRAULIC ENGINEER
TO SPECIFY DIMENSIONSPU PURLIN-Z10012 @ 1200crs LAPPED 900.MIDSPAN BRIDGING.
REFER STRUCTURAL DWGS..RA-RB1 STEEL RAFTER-200UB25. REFER STRUCTURAL DWGS.RA-RB2 STEEL RAFTER-150PFC. REFER STRUCTURAL DWGS.RF-SP INSULATION SPACER - FLETCHER ROOF RACKSKT-2 ALUMINIUM SKIRTING-200mmHST-S1 STEEL STRUT-150PFC. REFER STRUCTURAL DWGS.WA-01 EXTERNAL WALL - LYSAGHT CUSTOM ORB CLADDING, 35mm
STEEL TOP HATS, PROMINA 60 BOARD, FLETCHER TITANTUFF™WALL WRAP WITH R2.7 90MM PINK® SONOBATTS® PREMIUM,92mm STEEL STUD FRAMING, 9mm CSR CEMINTEL FIBRE CEMENTWALL PANELS.
WA-02 EXTERNAL WALL - OUT: EXTERIOR GRADE FC WALL PANELS TOMATCH EXISTING, EXISTING LEVEL B WALL :LEVEL B WORKSHOP
WA-07 INTERNAL PANELS - 9mm FIBRE CEMENT WALL PANELS
0
SCALE 1: AT ORIGINAL SIZE
100 200 300 400 500 mm
10
SCALE 1 : 1019-A400DETAIL SECTION E1
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
LEGEND
RELOCATEDNEWEXISTING
NOT IN SCOPE
SKT-2
WA-03EXISTING CONCRETE COLUMN
DOOR TO SUIT WIDTH860
WA-G
COS973
COS300 dia
COS2552
COS
3250
154A
200
SS WALL GUARDS (WA-G)
NEW FC LINED STUDWALL (WA-03)
WORKSHOP 3 WORKSHOP 4 WORKSHOP 6
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
WA-E
SKT-2
WA-03
EX1WORKSHOP 4
WA-G
NEW 9mm FC LININGS,ACOUSTIC INSULATION &SKIRTINGS SK-02 ON ALLEXISTING PLYWOODWALLS IN WORKSHOP 4
COS5050110
2124
WORKSHOP 1
SKT-2
W2
WORKSHOP 5
CONCRETE SCREED TO MATCH FLOORLEVEL OF NEW WORKSHOP 1 & EXISTINGWORKSHOP 3 FLOOR SLABS (0 RL). EPOXYFINISH (FS-EP) AS SPECIFIED.
COS
80
CC-1
NEW WORKSHOP 1CONCRETE FLOOR SLAB(CC-1)
NEW FC LINED STUD WALL (WA-03)
NEW WALL OPENING
WORKSHOP 4EX1
WA-G
SKT-2 SKT-2
EXISTING COLUMN
WORKSHOP 1
WA-G WA-GWALL INFILL
SKT-2
WA-05
SKT-2
WORKSHOP 3
2140
EXIT LIGHTING (EX1)RUNNING MAN EXIT LUMINAIRETO MATCH EXISTING.
WORKSHOP 6
COS1393
COS630
COS1233
COS574
INFILL WALL WA-05 THEN LINEENTIRE WALL WITH FCPAINTED TO MATCH EXISTING
NEW OPENING WITH SS WALLGUARD (WA-G)
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
2140
1800
CONCRETE SCREED TO MATCH LEVEL OFWORKSHOP 1 & 3 FLOOR SLABS (0 RL).EPOXY FINISH (FS-EP) AS SPECIFIED.
COS
80
WORKSHOP 4WORKSHOP2 & 3
SKT-2
WA-05
WA-E
EXISTING COLUMN EXISTING COLUMN
1360 1000
WA-GWA-G
SKT-2
WA-03
NEW 9mm FC LININGS,ACOUSTIC INSULATION &SKIRTINGS SK-02 ON ALLEXISTING WALLS INWORKSHOP 4
NEW OPENING WITH SSWALL GUARDS (WA-G)
WORKSHOP 5WORKSHOP 1
CC-1
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 6:36:46 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A560
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
INTERNAL ELEVATIONS - WORKSHOP 4 - 19A10417.08.16
J. DAVID*
JL JL* DB*
ARCHITECTURE
0ISSUE FOR TENDER0 10.02.17
FOR TENDER
23-15844
HPC SSSM BUILDING WORKS0
SCALE 1: AT ORIGINAL SIZE
200 400 600 800 1000 mm
20
N
SCALE 1 : 2019-A220INT ELEVATION A - RM 19A104A
SCALE 1 : 2019-A220INT ELEVATION B - RM 19A104B
SCALE 1 : 2019-A220INT ELEVATION C - RM 19A104C
SCALE 1 : 2019-A220INT ELEVATION D - RM 19A104D
BUILDING FABRIC & FINISHES SCHEDULE..
KEYNOTE DESCRIPTIONCC-1 CONCRETE - FLOOR SLAB - TO ENGINEER'S DESIGNEX1 EMERGENCY EXIT SIGNAGE-SINGLE SIDED-RUNNING MANSKT-2 ALUMINIUM SKIRTING-200mmHW2 NEW DOUBLE GLAZED LIDCO 715 SERIES SYSTEM-LEVEL
A-EASTWA-03 INTERNAL WALL - IN: 9mm FC SHEETING,92mm RONDO
STEEL STUDS WITH ACOUSTIC INSULATION,9mm FCSHEETING : OUT
WA-05 INTERNAL WALL - TO INFILL OPENING - LYSAGHT CUSTOMORB CLADDING, WALL INSULATION (OPTIONAL), 92mmSTEEL STUD FRAMING, PLYWOOD, . WALL TO MATCHEXISTING
WA-E EXISTING COLORBOND CUSTOM ORB CLAD TIMBER STUDFRAMED EXTERNAL WALL
WA-G S/S WALL GUARD
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
LEGEND
RELOCATEDNEWEXISTING
NOT IN SCOPE
SKT-2
WA-03EXISTING CONCRETE COLUMN
DOOR TO SUIT WIDTH860
WA-G
COS973
COS300 dia
COS2552
COS
3250
154A
200
SS WALL GUARDS (WA-G)
NEW FC LINED STUDWALL (WA-03)
WORKSHOP 3 WORKSHOP 4 WORKSHOP 6
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
WA-E
SKT-2
WA-03
EX1WORKSHOP 4
WA-G
NEW 9mm FC LININGS,ACOUSTIC INSULATION &SKIRTINGS SK-02 ON ALLEXISTING PLYWOODWALLS IN WORKSHOP 4
COS5050110
2124
WORKSHOP 1
SKT-2
W2
WORKSHOP 5
CONCRETE SCREED TO MATCH FLOORLEVEL OF NEW WORKSHOP 1 & EXISTINGWORKSHOP 3 FLOOR SLABS (0 RL). EPOXYFINISH (FS-EP) AS SPECIFIED.
COS
80
CC-1
NEW WORKSHOP 1CONCRETE FLOOR SLAB(CC-1)
NEW FC LINED STUD WALL (WA-03)
NEW WALL OPENING
WORKSHOP 4EX1
WA-G
SKT-2 SKT-2
EXISTING COLUMN
WORKSHOP1
WA-G WA-GWALL INFILL
SKT-2
WA-05
SKT-2
WORKSHOP 3
2140
EXIT LIGHTING (EX1)RUNNING MAN EXIT LUMINAIRETO MATCH EXISTING.
WORKSHOP 6
COS1393
COS630
COS1233
COS574
INFILL WALL WA-05 THEN LINEENTIRE WALL WITH FCPAINTED TO MATCH EXISTING
NEW OPENING WITH SS WALLGUARD (WA-G)
RLLEVEL B
614.960 m
RLLEVEL A
611.460 m
2140
1800
CONCRETE SCREED TO MATCH LEVEL OFWORKSHOP 1 & 3 FLOOR SLABS (0 RL).EPOXY FINISH (FS-EP) AS SPECIFIED.
COS
80
WORKSHOP 4WORKSHOP2 & 3
SKT-2
WA-05
WA-E
EXISTING COLUMN EXISTING COLUMN
1360 1000
WA-GWA-G
SKT-2
WA-03
NEW 9mm FC LININGS,ACOUSTIC INSULATION &SKIRTINGS SK-02 ON ALLEXISTING WALLS INWORKSHOP 4
NEW OPENING WITH SSWALL GUARDS (WA-G)
WORKSHOP 5WORKSHOP 1
CC-1
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 6:36:09 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A560
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
INTERNAL ELEVATIONS - WORKSHOP 4 - 19A10417.08.16
J. DAVID*
JL JL* DB*
ARCHITECTURE
0ISSUE FOR TENDER0 10.02.17
FOR TENDER
23-15844
HPC SSSM BUILDING WORKS0
SCALE 1: AT ORIGINAL SIZE
200 400 600 800 1000 mm
20
N
SCALE 1 : 2019-A220INT ELEVATION A - RM 19A104A
SCALE 1 : 2019-A220INT ELEVATION B - RM 19A104B
SCALE 1 : 2019-A220INT ELEVATION C - RM 19A104C
SCALE 1 : 2019-A220INT ELEVATION D - RM 19A104D
BUILDING FABRIC & FINISHES SCHEDULE..
KEYNOTE DESCRIPTIONCC-1 CONCRETE - FLOOR SLAB - TO ENGINEER'S DESIGNEX1 EMERGENCY EXIT SIGNAGE-SINGLE SIDED-RUNNING MANSKT-2 ALUMINIUM SKIRTING-200mmHW2 NEW DOUBLE GLAZED LIDCO 715 SERIES SYSTEM-LEVEL
A-EASTWA-03 INTERNAL WALL - IN: 9mm FC SHEETING,92mm RONDO
STEEL STUDS WITH ACOUSTIC INSULATION,9mm FCSHEETING : OUT
WA-05 INTERNAL WALL - TO INFILL OPENING - LYSAGHT CUSTOMORB CLADDING, WALL INSULATION (OPTIONAL), 92mmSTEEL STUD FRAMING, PLYWOOD, . WALL TO MATCHEXISTING
WA-E EXISTING COLORBOND CUSTOM ORB CLAD TIMBER STUDFRAMED EXTERNAL WALL
WA-G S/S WALL GUARD
1020
S1
H
H
H
H
HA2120
EXTERNAL ELEVATION
SECURITY CARD READER (CDR)CARD ENTRY & EXIT PROXIMITYREADER TO MATCH EXISTING
FIRE EXIT SIGNAGE (S1)SIGNAGE TO READ "FIRESAFETY DOOR, DO NOTOBSTRUCT, DO NOT KEEPOPEN" IN COMPLIANCE WITHNCC, BCA D2.23(B)(i).SIGNAGE MATERIAL TOMATCH EXISTING.
HINGE (H)4 OFF 100 x 75 x 2.5mmNOVAS BUTTON TIPPED S/SBALL BEARING TYPE HINGESOR SIMILAR. MINIMUM 4 PERDOOR, FIXED PIN.
150A
CDR
LEVER PLATE & HANDLE (HA)NOVAS SERIES P - LEVER 50WITH SNIB DOOR & KEYHOLEOR A SIMILAR AS1428.1COMPLIANT DOOR HANDLE.HANDLE TO BE INSTALLED @1000mm FROM FFL.
KP
KICK PANEL (KP)KICKPLATE - 304 S/SCONCRETE HOB HEIGHT xDOOR LEAF WIDTH, TO BESCREWED AND GLUED INTOPOSITION. FIXINGS ONSECURE SIDE ONLY.
1000
RLLEVEL A
611.460 m
S1
1000
INTERNAL ELEVATION
PB
KP 300
LIGHT SWITCHESCOMFIRM & CO-ORDINATEWITH ELECTRICALDRAWINGS
1300
EX1
EXIT LIGHTING (EX1)RUNNING MAN EXIT LUMINAIRETO MATCH EXISTING. REFERELECTRICAL DWGS FORDETAILS.
PUSH BAR EMERGENCY EXIT (PB)LOCKWOOD 9300/9500 SERIESELECTROMECHANICAL VERTICALTYPE PANIC EXIT DEVICE.
SKT-2 SKT-2
KICK PANEL (KP)KICKPLATE - 304 S/S 300mmh xDOOR LEAF WIDTH, TO BESCREWED AND GLUED INTOPOSITION. FIXINGS ONINTERNAL SIDE.
DOOR FRAME50mm WIDTH STEEL DOORFRAMES WITH 1.6mm BMT .
DOOR LEAFPAINTED TIMBER SOLID CORE45mm 2HR FIRE RATED DOORWITH NO EDGE TRIM.
150A
DC DOOR CLOSER (DC)FOR AS1428.1 COMPLIANCE THEFORCE TO OPEN & CLOSE DOORSHALL NOT EXCEED 20N.RECOMMENDED, GEZE TS4000 DANHO SIL SCISSOR ARM OR ASIMILAR AS1428.1 COMPLIANTSYSTEM. .
RS
REED SWITCH (RS)TO MATCH EXISTING
CDR
BGD
BREAK GLASSDETECTOR (BGD)TO MATCH EXISTING
2700
EXTERNAL ELEVATIONRLLEVEL A
611.460 m
2180
240
2700
INTERNAL ELEVATION
FB FB
FLUSH BOLTADI SLIMLINE SL5 PADLOCKWITH MASTER KEY SYSTEM
DRUM
AS1905.2 COMPLIANT SERIES75 AIRPORT ROLLER SHUTTERSWITH 2 HR FIRE RATING. TO BEPOWDERCOATED TO THECOLOUR SPECIFIED IN THECOLOURBOARD ON DWG A300.
S1
KP
H
H
H
H
HA
EXTERNAL ELEVATION
1000
2060
1020
CDR
1300
300
RLLEVEL B
614.960 m
KP
INTERNAL ELEVATION
S1
PB
EX1
DC
DOOR FRAME50mm WIDTH STEEL DOORFRAMES WITH 1.6mm BMT.TO BE CO-ORDINATED WITHTHE FACADE WORKS.
DOOR LEAFPAINTED TIMBER SOLID CORE45mm 2HR FIRE RATED DOORWITH NO EDGE TRIM.
RS
CDRBGD
EXIT LIGHTING (EX1)SECURELY FIX RUNNING MANEXIT LUMINAIRE TO WINDOWFRAME. LIGHT SIGNAGE TOMATCH EXISTING. REFERELECTRICAL DWGS FORDETAILS.
LEVEL B
BGD BREAK GLASS DETECTORCDR SECURITY CARD READERDC DOOR CLOSEREX1 RUNNING MAN EXIT SIGNAGEH HINGESHA HANDLES & PLATESKP S/S KICKPLATESPB PUSH BAR EXITRS REED SWITCHSKT SKIRTINGVS VISION PANEL
DOOR LEGEND
ALL DOOR FRAMES AND DOOR LEAFS ARE TO BE CONFIRMEDBY CONTRACTOR WITH FINAL WALL DIMENSIONS PRIOR TOFABRICATION. ALL DOOR HARDWARE IS TO BE INSTALLED BY AQUALIFIED LOCKSMITH, PROVIDE EVIDENCE OF QUALIFICATIONS.CONTRACTOR SHALL CONFIRM THE LENGTH OF BACKSETS FORALL DOORS FITTED WITH FIRE SEALS AND PROVIDE CORRECTLENGTH TO SUIT. HEAD CONTRACTOR AND THE DOORCONTRACTOR SHALL CO ORDINATE THE INSTALLATION OF ALLDOOR HARDWARE DEVICES TO AVOID CUTTING SEALS ANDFOULING DOOR HARDWARE.ALL DOORS & DOOR HARDWARE TO BE SELECTED &CONSTRUCTED TO AS/NZS 1905.1 (2HR RATED FIRE DOOR) &AS1428.1 (DESIGN FOR ACCESS & MOBILITY).
DOOR NOTES & SPECIFICATIONS
GENERAL NOTES
TO BE COMPATABLE WITH THE EXISTING CARD SYSTEM ASSPECIFIED BY AUSTRALIAN SPORTS COMMISSION (ASC). USE AMAGNETIC REED SWITCH TO MATCH EXISTING. PROGRAMME CARDREADER TO DEACTIVATE DOOR LOCK ON FIRE TRIP OR POWERFAILURE. OBTAIN NEW CYLINDERS & KEY TO EXISTING KEYINGSYSTEM. ASC TO CONFIRM ALL KEYING SYSTEMS. CONTRACTORTO PROVIDE KEYING SCHEDULE FOR APPROVAL
CARD & KEYING SYSTEMS (CDR)
DOOR CLOSERS TO HAVE ALL NECESSARY BRACKET, FIXINGS,CORRECT VALVES AND BE SELECTED TO SUIT THE DOOR LEAFSIZE AND FUNCTION. DOOR CLOSERS TO HAVE ABILITY TO BEADJUSTED TO 1 AND 20N OPENING FORCE TO COMPLY WITHAS1428.1. CO-ORDINATE CLOSER WITH ALL SECURITY FIXTURES.IT MAY BE NECESSARY TO HAVE THE CLOSER EXTERNALLY ORINTERNALLY MOUNTED DEPENDING ON REMAINING SPACEALLOWANCES .
CLOSERS (DC)
DOOR FRAME & JAMB TO BE FIRE RATED. TYPICALLY SECUREDOOR FRAMES BACK TO STRUCTURE. DOOR FRAME FROM THEFACTORY MUST BE FABRICATED WITH CUT OUTS AND BACKINGPLATES TO ACCOMMODATE THE STRIKER TONGUE AND FERRULEPLATES. TYPICALLY ALLOW A 5mm TOLERANCE BETWEEN FRAMEEDGE AND BASE WALL, SEAL GAP WITH MASTIC FIRE RATEDSEALANT. TYPICALLY ALLOW A 2mm TOLERANCE BETWEEN DOORFRAME AND BACK OF REBATE AND 1mm AT THE FACE. BASEMETAL THICKNESS OF A MINIMUM 1.6 MM.
DOOR FRAME & JAMB
PROVIDE ALL HARDWARE, SEALS AND INTERFACE / COORDINATEWITH SECURITY DEVICES & ACCESS CONTROL SYSTEMS IFSPECIFIED. DOOR LEAF MUST BE FIRE RATED TO 2 HOURS.
DOOR LEAF
ALL EXPOSED FIXINGS TO BE ON THE SECURE SIDE.TYPICALLY PRIMARY DOOR HARDWARE TO BE 1000mm FROM THEFINISHED FLOOR LEVEL.
FURNITURE TYPE (HA)
CONTRACTOR TO CONFIRM SPECIFIED HINGE TYPE PRIOR TOORDERING. WELD HINGES TO FRAME OR USE POP RIVETS.
HINGE TYPE
ALL KICK PLATES TO BE SCREWED AND GLUED IN POSITION ANDPROVIDED TO BOTH SIDES OF THE DOOR LEAF. ALLOW FORBOTTOM THRESHOLD SEALS
KICK PLATES
ALL VISIBLE FIXINGS TO BE ON THE SECURE SIDE. ALL HANDLESTO BE SELECTED & INSTALLED TO BE AS1428.1 COMPLIANT LEVERHANDLES.
LEVER PLATES
FIRE DOOR SEALS REQUIREDTHRESHOLD PLATE: RAVEN RP115, WIDE THRESHOLD PLATE
75x6mmHEAD: RAVEN RP120 BAT WINGJAMB: RAVEN RP78Si
ALL DOOR & DOOR THRESHOLDS MUST BE CONSTRUCTED TOAS1428.1 & FIRE RATED
SEALS
NOVAS 250 SC, DOOR STOPS TO LIMIT WALL DAMAGE BY DOORHANDLES BUT POSITIONED TO AVOID TRIPPING.
STOPS
CLIENT TO CONFIRM IF STRIKER SHIELDS ARE REQUIRED. IFREQUIRED USE NOVAS NH097 GRADE 316 STEEL STRIKER SHIELD.
STRIKER SHIELD (SS)
ROLLER DOOR NOTES & SPECIFICATIONS
GENERAL NOTES
KEYING SYSTEM TO MATCH EXISTING BUILDING SYSTEM.CONTRACTOR TO PROVIDE KEYING SCHEDULE FOR APPROVALAND KEYING HIERARCHY, CONSULT WITH CLIENT FOR MASTERKEYING SYSTEM AND HIERARCHY.HAND-OPERATEDSERIES 75 ROLLER SHUTTERS ARE FITTED WITH TWOSHOOT-BOLTS, FITTED INTERNALLY OR EXTERNALLY TO EACHEND OF THE BOTTOM RAIL.CHAIN OPERATEDSTEEL ROLLER SHUTTERS ARE TO BE FITTED WITH A STEELCHAIN LOCK DESIGNED TO ACCOMMODATE A PAD BOLT.ELECTRIC OPERATED (MOTORISED)DOORS ARE SECURED BY THE MOTOR AND ITS CONTROLS.
KEYING/LOCKING SYSTEMS
PROVIDE WIND LOCK END CLIPS AND GUIDES TO RETAIN THECURTAIN IN WIDE OPENINGS OR UNDER EXTREME WINDCONDITIONS. WINDLOCK CLIPS SHALL BEINSTALLED AND 1.6MM HD ALUM. BOX SECTION SHALL BEINSTALLED AT THE BOTTOM AND FITTED WITH A FIRE & WEATHERSEAL.
WINDLOCKSMAXIMUM DRUM DEFLECTION: 1/360TH OF THE SPAN.SPRINGS: HELICAL TORSION SPRINGS HOUSED IN THE DRUM ANDARRANGED TO COUNTERBALANCE THE CURTAIN WEIGHT WITHOUTEXCEEDING THE SAFE WORKING STRESS OF THE SPRING MATERIAL.
DRUM
PROVIDE DOORS WITH METAL FRAME AND FACINGS TO MATCHTHE CURTAIN, AND MANUFACTURER’S STANDARD LOCKSET ANDFURNITURE.
WICKETS
CLIENT TO CONFIRM OPERATION TYPE.MANUAL OPERATION- INSTALL SO THAT THE FORCE REQUIRED TO OPERATE THE DOOR
MANUALLY DOES NOT EXCEED 220 N.MOTORISED OPERATION- MANUAL RELEASE HANDLE TO DISENGAGE DOOR FROM DRIVE
MECHANISM IN THE EVENT OF A POWER FAILURE.- OPERATION BY BATTERY-POWERED RADIO REMOTE
CONTROLLER, SUPPLIED AS PART OF THE SYSTEM.. QUANTITY OF PROGRAMMED REMOTE CONTROLLERS: CLIENT TO
CONFIRM. MEMORY REGISTER QUANTITY: CLIENT TO CONFIRM- ADDITIONAL OPERATION BY PUSH-BUTTON OR KEY SWITCH,
LOCATED 1500 MM ABOVE FLOOR LEVEL.
OPERATION
REQUIREMENT: INSTALL FRAMES AS FOLLOWS:- PLUMB, LEVEL, STRAIGHT, TRUE, AND WITHIN TOLERANCES AND
CLEARANCES RECOMMENDED BY THE MANUFACTURER.- FIXED OR ANCHORED TO THE BUILDING STRUCTURE USING
MECHANICAL FIXINGS SUITABLE FOR THE SUBSTRATE AND THEIMPOSED LOADS.
- ISOLATED FROM ANY BUILDING LOADS, INCLUDING LOADS CAUSEDBY STRUCTURAL DEFLECTION OR SHORTENING.
FRAMES
PROVIDE A STIFFENING MEMBER AS FOLLOWS:- INTERLOCKING WITH THE BOTTOM EDGE OR LOWEST PART OF THE
CURTAIN.- EXTENDING BETWEEN THE INNER FACES OF THE VERTICAL GUIDES.- FORMED OR ADAPTED AS REQUIRED TO FOLLOW THE CONTOUR OF A
SLOPING FLOOR OR THRESHOLD.- ADAPTED TO HOUSE A LOCKING DEVICE, IF REQUIRED.
BOTTOM RAIL
AS1905.2 COMPLIANT SERIES 75 AIRPORT ROLLER SHUTTERS WITH 2HR FIRE RATING. ROLL FORMED 1.0mm GALVANISED STEEL SLATSWITH 75mm PROFILE ARE TO BE POWDERCOATED TO THE COLOURSPECIFIED IN THE COLOURBOARD ON DWG A300.
TYPE & FINISH
2HR FIRE RATED DOOR GUIDES ARE TO BE MANUFACTURED FROM2.5MM THICK ROLL-FORMED GALVANISED STEEL WITH A DEPTH OF78mm. DOOR GUIDES ARE WELDED DIRECTLY TO STEEL COLUMNS.
GUIDES
THE ROLLER DOOR FRAME AND SHUTTER ARE TO BECONFIRMED BY CONTRACTOR WITH FINAL WALL DIMENSIONSPRIOR TO FABRICATION. ALL DOOR HARDWARE IS TO BEINSTALLED IN ACCORDANCE WITH MANUFACTURER'SSPECIFICATIONS. HEAD CONTRACTOR AND THE DOORCONTRACTOR SHALL CO ORDINATE THE INSTALLATION OF ALLDOOR HARDWARE.
ADI SLIMLINE SL5 PADLOCK WITH MASTER KEY SYSTEM. THE FIXINGSSHOULD BE BOLTED RIGHT THROUGH THE DOOR LEAF WITH DOMEDHEADS ON THE EXTERNAL SIDE. WHEN USED ON ROLLER DOORSPROVIDE OPERATION LIMITER TO AVOID OVER LOADING THE MOTORS.
FLUSH BOLT
PROVIDE RAVEN FIRE DOOR & WEATHER SEALSJAMB : REFER WIND LOCKSTHRESHOLD: RAVEN RP115, WIDE THRESHOLD PLATE 75x6mmHEAD: RAVEN RP74
SEALS
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
INTERNAL ELEVATION
83DOOR TO SUIT WIDTH
820 79
KP
H
H
H
H
HA
VP
DCEXISTINGCOLUMN
S3
CONTRACTOR TO PROVIDENON FIRE EGRESS DOOR TOSUIT WIDTH BETWEENEXISTING WALL & COLUMN.
RS
RLLEVEL A
611.460 m
XX2
EXTERNAL ELEVATION
KP
HA
VP
STEP DOWN AT DOORTHRESHOLD TOWORKSHOP 5 - 19A105.CHECK LEVELS ON SITE
WA-03
S2
8021
00
700
300
200
600
200
WARNING SIGNAGE (S2)SIGNAGE TO READ,"WARNING, STEP UP".SIGNAGE MATERIAL TOMATCH EXISTING.
VISION PANEL (VS)AS1288 COMPLIANTSAFETY GLASS
WARNING SIGNAGE (S3)SIGNAGE TO READ,"WARNING, STEPDOWN". SIGNAGEMATERIAL TO MATCHEXISTING.
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 6:37:24 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A800
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
DOOR ELEVATION & SPECIFICATIONS10.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 20DOOR ELEVATIONS 150A
SCALE 1 : 20DOOR ELEVATIONS 151A
SCALE 1 : 20DOOR ELEVATIONS 150B
0
SCALE 1: AT ORIGINAL SIZE
200 400 600 800 1000 mm
20
SCALE 1 : 20DOOR ELEVATION 154A
RLLEVEL A
611.460 m
D
C L10
89C L
1091 W2
NEW
WOR
KSHO
P EX
TENS
ION
50 950 50 950 50 900 50
NEW DOUBLE GLAZED LIDCO 715 SERIESFRAMING TO MATCH EXISTING. GLASSTO BE AS1288 COMPLIANT WITH HIGHSOLAR PERFORMANCE. USE FLASHINGSTO MATCH THE COLOUR OF ADJACENTWALL. FIRE SEALANT FOR JOINTING.
3000
EXIS
TING
BUILD
ING
EXTE
NSIO
N
561
GENERAL NOTES:
ALL NEW WORK TO BE UNDERTAKEN INACCORDANCE WITH THE CURRENT NCC (BCA),REFERENCE APPLICABLE AUSTRALIANSTANDARDS & LOCAL AUTHORITYREQUIREMENTS.ALL DIMENSIONS & LEVELS TO BE CHECKED &CONFIRMED ON SITE PRIOR TOCOMMENCEMENT OF CONSTRUCTION.FOR STRUCTURAL, ELECTRICAL & HYDRAULICINFORMATION, REFER TO ENGINEER'SDETAILS.ALL DRAWINGS MUST BE READ INCONJUNCTION WITH NOTES, SCHEDULES &SPECIFICATIONS.REFER TO KEYNOTES & FFE SCHEDULE FORDETAILS OF ALL CODED ELEMENTS SHOWN ONTHE DRAWINGS.REFER TO THE SCHEDULES & COLOURBOARDON ELEVATION DRAWINGS 19-A300 FOR ALLFINISHES & COLOUR SELECTIONS.ALL FLOOR SURFACES SHOULD BE DESIGNED& CONSTRUCTED IN ACCORDANCE WITHAS/NZS 4586, HB197 & STANDARDS AUSTRALIAFOR SLIP RESISTANCE.WATERPROOFING TO COMPLY WITH AS3740.TERMITE MANAGEMENT AS PER AS3660.1
1.
2.
3.
4.
5.
6.
7.
8.
9.10.
LEGEND
NEW
EXISTING
CLIENT TO VIEW A MOCK OF SAMPLE OR INSPECTA COMPLETED BUILDING BEFORE CONFIRMATIONIS GIVEN TO GLASS DESIGN/ SPECIFICATION.- PROVIDE NEW WINDOW SILL AND FLASHINGS.- ALL DIMENSIONS, SETOUTS, LEVELS AND FINISHBUILDINGS RL'S TO BE CONFIRMED ON SITEBEFORE COMMENCING WORK. DO NOT SCALEDRAWINGS.- CHECK ON SITE ALL BUILT DIMENSIONS &EXISTING STRUCTURE MEASUREMENTS PRIOR TOSHOP DRAWINGS AND FABRICATION.CONTRACTOR TO PROVIDE SHOP DRAWINGS FORARCHITECTURE APPROVAL PRIOR TO ANYFABRICATION OF WORKS.NOM DIM* - NOMINAL DIMENSIONS - REFERMECHANICAL ENG. DRAWINGS FOR DETAILS(GRILLES DIMENSIONS, TYPES, AND FIXINGDIMENSION ABOVE FFL)
WINDOW NOTES & SPECIFICATIONS
GENERAL NOTES
ALL GLASS TO BE SELECTED AND INSTALLED INACCORDANCE BUT NOT EXCLUSIVELY WITH THEFOLLOWING AUSTRALIAN AND/ OR NEW ZEALANDSTANDARDS.- AS 1288 GLASS IN BUILDINGS SELECTION ANDINSTALLATION- AS 1170 MINIMUM WIND LOADS ON STRUCTURES- AS/NZ 2208 SAFETY GLAZING MATERIALS INBUILDINGS- AS/NZ 4666 INSULATING GLASS UNITS- AS/NZ 4667 QUALITY REQUIREMENTS FORCUT-TO-SIZE AND PROCESSED GLASS
AUSTRALIAN STANDARDS
PROVIDE JOINTING MATERIALS TO MANUFACTURER'SRECOMMENDATIONS WHICH ARE COMPATIBLE WITH EACH OTHERAND WITH THE CONTACT SURFACES AND NON-STAINING TOFINISHED SURFACES. DO NOT PROVIDE BITUMINOUS MATERIALSON ABSORBENT SURFACES.MAKE ACCURATELY FITTED TIGHT JOINTS SO THAT NEITHERFASTENERS NOR FIXING DEVICES SUCH AS PINS, SCREWS,ADHESIVES AND PRESSURE INDENTATIONS ARE VISIBLE ONEXPOSED SURFACES.SEALANTS: IF PRIMING IS RECOMMENDED, PRIME SURFACES INCONTACT WITH JOINTING MATERIALS. IF FRAMES ARE POWDERCOATED, APPLY A NEUTRAL CURE SEALANT.
JOINTING
GENERAL: CORROSION RESISTANT, COMPATIBLE WITH THEOTHER MATERIALS IN THE INSTALLATION, AND COATED WITH ANON-STAINING COMPOUND WHERE NECESSARY.STANDARD: TO AS/NZS 2904.
FLASHING
GENERAL: INSTALL WINDOWS AND GLAZED DOORS FRAMES ASFOLLOWS:- PLUMB, LEVEL, STRAIGHT AND TRUE WITHIN BUILDINGTOLERANCES.- FIXED OR ANCHORED TO THE BUILDING STRUCTURE INCONFORMANCE WITH THE WIND ACTION LOADINGREQUIREMENTS.- ISOLATED FROM ANY BUILDING LOADS, INCLUDING LOADSCAUSED BY STRUCTURAL DEFLECTION OR SHORTENING.- ALLOW FOR THERMAL MOVEMENT.
INSTALLATION
FLASHING AND WEATHERINGS: INSTALL FLASHINGS, WEATHERBARS, DRIPS, STORM MOULDS, CAULKING AND POINTING SOTHAT WATER IS PREVENTED FROM PENETRATING THEBUILDING BETWEEN THE WINDOW FRAME AND THE BUILDINGSTRUCTURE UNDER THE PREVAILING SERVICE CONDITIONS,INCLUDING NORMAL STRUCTURAL MOVEMENT OF THEBUILDING
WATERPROOFING
REQUIREMENT: PROVIDE THE STANDARD HARDWARE ANDINTERNAL FIXING POINTS FOR PERSONNEL SAFETY HARNESSATTACHMENT, IF REQUIRED BY AND CONFORMING WITH THEGOVERNING REGULATIONS
PROPRIETARY WINDOW SYSTEMSFASTENERS AND FASTENER SPACING: CONFORM TO THERECOMMENDATIONS OF THE MANUFACTURER.FASTENERS: CONCEAL FASTENERS. PROVIDE A CORROSION-RESISTANT FINISHPACKING: PACK BEHIND FIXING POINTS WITH DURABLE FULL WIDTHPACKING.
FASTENERS
RLLEVEL A
611.460 m
XX1 XX5XX2
EXISTING LEVEL B LIDCO 715 SINGLEGLAZED RIBBON WINDOW & GLAZEDLOUVER SYSTEMCO
SEQ
XX3 XX4
NEW LIDCO 715 DOUBLE GLAZED RIBBONWINDOW & GLAZED LOUVER SYSTEM TOMATCH TO THE EXISTING LEVEL BWINDOW SYSTEM I.E SPACING OF FRAME,FRAME TYPE, SIZE OF GLAZED PANELARE TO MATCH THE EXISTING LEVEL BWINDOW SYSTEM. CONFIRM SPACINGAND ALIGNMENT ON SITE. GLASS TO BEDOUBLE GLAZED & AS1288 COMPLIANTWITH HIGH SOLAR PERFORMANCE. USEFLASHINGS TO MATCH THE COLOUR OFADJACENT WALL. FIRE SEALANT AT ALLJUNCTIONS.TO
MAT
CH LE
VEL B
WIN
DOW
S12
0090
0
W1
ALIG
NAL
IGN
ALIG
NAL
IGN
ALIG
NAL
IGN
ALIG
NAL
IGN
ALIG
NAL
IGN
ALIG
NAL
IGN
ALIG
NAL
IGN
ALIG
NAL
IGN
ALIG
NAL
IGN
ALIG
NAL
IGN
CC-2 CONCRETE HOB
EXISTING WORKSHOPWINDOWSLEVEL B
NEW WORKSHOPWINDOWSLEVEL ASSSM HALL
CLCLCLCLCLCLCLCLCLCOS575
COS590 1320 1500 600 1500 1500 600 1500 1500 600 1200
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
13/02/2017 6:38:03 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A810
J. LUCAS J. LUCAS
D. BELL*
D. BELL*
WINDOW ELEVATIONS & SPECIFICATIONS10.02.17
J. DAVID*
JL JL* DB*
ARCHITECTURAL SERVICES
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 2019-A300WINDOW ELEVATION W2 - EAST2
0
SCALE 1: AT ORIGINAL SIZE
200 400 600 800 1000 mm
20
SCALE 1 : 2019-A210WINDOW ELEVATION W1 - SOUTH1
RA-RB2
RA-RB1
COL-SC2
COL-SC1
WD-WS1
WD-WS2
WD-WS1
WD-WS1
WD-WS1
WD-WS1
WD-WS2
WD-WS1
CC-2
COL-SC1
COL-SC1
COL-SC1
BR-VB1
BR-BR1
PO-DP1PO-DP1
WD-WS1
WD-WS1
PO-DP1PO-DP1
PO-DP1PO-DP1
PO-DP1
CC-2CC-1
CC-1
WD-WS1WD-WS1
RF-SP
PU
COL-EX
ALL ROOF BEAMS RA-RB1 ARETO CONNECT TO EXISTINGCOLUMNS COL-EX
BR-VB1
COL-EX
COL-EX
COL-EX
BR-BR1
BR-BR1
BR-BR1
ST-S1
CC-4
STR-E
COL-4
COL-4
LANDING TO BE FIXED TOLEVEL B FLOOR SLAB &SUPPORTED BY 2 OFF CHS TOENGINEER'S DETAILS.
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
13/02/2017 6:44:13 PM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-A950
J. LUCAS J. LUCAS
-
-
3D PERSPECTIVES-
-J.L J.L D.B
J.L J.L D.B
J.L J.L D.B
ARCHITECTURE
CISSUE FOR CLIENT REVIEWA 19.07.16
ISSUE FOR INFORMATION ONLYB 17.08.16
ISSUE FOR INFORMATION ONLYC 10.02.17
FOR INFORMATION ONLY
23-15844
HPC SSSM BUILDING WORKS
SCALE3D PERSPECTIVE 12
SCALE3D PERSPECTIVE 23
SCALESTRUCTURAL 3D1
GENERAL CONDITIONS
INFORMATION
CODES, RULES, PERMITS, FEES
DEFECTS LIABILITY
LOCATION OF SERVICES
WORKSHOP DRAWINGS AND SAMPLES
WORKMANSHIP
LICENSED ELECTRICAL CONTRACTOR
RELATED ELECTRICAL WORKS
SCOPE OF WORK
BACKGROUND
DEMOLITION
LIGHTING
LIGHTING CONTROLS
EMERGENCY AND EXIT LIGHTING
GENERAL POWER
OUTLETS AND ACCESSORIES
FIRE DETECTION AND SSISEP
EARTHING
CABLE SELECTION
TESTING AND COMMISSIONING
AS-BUILT HARD COPY DRAWINGS ANDMAINTENANCE MANUALS
SPECIFICATION FOR ELECTRICAL SERVICESCO-ORDINATE THE LOCATION OF THE SERVICES UNDER CONTRACTOR'SWORK SCOPE WITH OTHER TRADES, AND TO SUIT HYDRAULIC ANDMECHANICAL SERVICES ETC. ALL WORK IS TO COMPLY WITH ALL RELEVANTBRIEFS & REQUIREMENTS.
THE CONTRACTOR IS TO FULLY INFORM THEMSELVES OF ALL ASPECTS OFTHIS EXISTING INSTALLATION PRIOR TO TENDER & COMMENCEMENT OFCONSTRUCTION. UNDERTAKE A MANDATORY SITE INSPECTION TO ASSESSTHE SCOPE OF DEMOLITION AND NEW WORKS. PARTICULAR ATTENTIONSHOULD BE PAID TO THE LOCATION OF THE EXISTING FIRE INDICATORPANEL, AND LOCATION OF EXISTING IN CEILING SMOKE DETECTION.
ALL MATERIALS, SUPPLIES, AND ALL WORK INSTALLED SHALL COMPLY WITHTHE CODES, STANDARDS, RULES AND REGULATIONS OF RELEVANTSTATUTORY AUTHORITIES INCLUDING, BUT NOT NECESSARILY LIMITED TO:
a. BUILDING CODE OF AUSTRALIA (2013)b. AS 3000:2007 ELECTRICAL INSTALLATIONS (WIRING RULES).c. AS/NZS 2293 PARTS 1 AND 2 (EMERGENCY LIGHTING)d. AS/NZS 3439 (SWITCHBOARDS)e. AS/NZS 3008 ELECTRICAL INSTALLATIONS - SELECTION OF CABLES.f. AS3017 ELECTRICAL INSTALLATIONS - TESTING GUIDELINESg. SUPPLY AUTHORITY REGULATIONS
MAKE ALL APPLICATIONS AND PAY ALL FEES REQUIRED TO COMPLY WITHRELEVANT AUTHORITY REQUIREMENTS, INCLUDING SELF-CERTIFICATIONCOSTS FOR ELECTRICAL INSPECTION, EMERGENCY LIGHTING ANDCOMMUNICATIONS.
GUARANTEE ALL WORK AND MATERIALS AS TO QUALITY, WORKMANSHIPAND AGAINST DEFECTS, FOR A PERIOD OF TWELVE MONTHS FROM THEDATE OF ISSUE OF THE 'CERTIFICATE OF PRACTICAL COMPLETION'. DURINGTHIS PERIOD, PROMPTLY REPLACE ALL DEFECTIVE EQUIPMENT, FIXTURESAND MATERIALS AT NO ADDITIONAL COST.
THE LOCATION AND MOUNTING HEIGHTS OF THE SERVICES SHOWN ON THEDRAWINGS ARE APPROXIMATE ONLY. FINAL LOCATIONS, MOUNTINGHEIGHTS AND SET-OUTS AS NOMINATED ON THE ARCHITECTURALDRAWINGS, AND SHALL BE CONFIRMED ON SITE PRIOR TO INSTALLATION.
SUBMIT THE FOLLOWING DETAILED SHOP DRAWINGS TO THESUPERINTENDENT FOR REVIEW PRIOR TO COMMENCING INSTALLATIONWORKS:· SWITCH BOARDALLOW A MINIMUM OF 10 WORKING DAYS FOR RECEIPT OF COMMENTS
PROVIDE THE FOLLOWING SAMPLES TO THE SUPERINTENDENT FORREVIEW PRIOR TO COMMENCING INSTALLATION WORKS:· LIGHT FIXTURES COMPETE WITH LAMPS AND CONTROL GEAR.· EMERGENCY LIGHTING· OCCUPANCY SENSORS· GENERAL PURPOSE OUTLETS.
ALL WORKMANSHIP AND MATERIALS SHALL BE TO THE SATISFACTION OFTHE SUPERINTENDENT. ALL MATERIALS SHALL BE NEW UNLESSOTHERWISE NOTED. ANY MATERIALS OR WORKMANSHIP, WHICH ARECONSIDERED INFERIOR OR NON-CONFORMING BY THE SUPERINTENDENTSHALL BE REPLACED AT THE CONTRACTOR'S COST.
ALL WORKS SHALL BE UNDERTAKEN BY LICENSED ELECTRICALCONTRACTOR'S, QUALIFIED AND EXPERIENCED IN THE TYPE OF WORKREQUIRED FOR THIS PROJECT.
CO-ORDINATE AND CO-OPERATE WITH THE BUILDER AND OTHER TRADES(MECHANICAL, HYDRAULIC, ETC) AS REQUIRED.
THE SCOPE OF WORK INCLUDES THE DEMOLITION, SUPPLY, DELIVERY,INSTALLATION, TESTING AND SETTING TO WORK OF THE SYSTEMS ANDEQUIPMENT AS SHOWN ON THE ELECTRICAL SERVICES DRAWINGS ANDNOMINATED IN THE SPECIFICATION. SUPPLY ALL REQUIRED MATERIALSUNLESS OTHERWISE SPECIFIED. REFER ARCHITECTURAL DRAWINGS FORFINAL SETOUT.
THE SCOPE OF WORK INCLUDES BUT IS NOT NECESSARILY LIMITED TO THEFOLLOWING:
THE AUSTRALIAN SPORTS COMMISSION REQUIRES MODIFICATIONS TO THEEXISTING SSSM BUILDING, WHICH INCLUDES RELOCATION OF THE EXISTINGWORKSHOP ON LEVEL A. THIS SHALL INCLUDE THE DEMOLITION OF EXISTINGELECTRICAL, LIGHTING, FIRE DETECTION AND COMMUNICATION SERVICES, ANDINSTALLATION OF NEW SERVICES AS OUTLINED ON THE DRAWINGS.IN DETAIL THIS WORKS SHALL INCLUDE:- RETENTION OF THE LOAD CENTRE LOCATED WITHIN THE LOWER
GROUND WELDING AREA AND RECONNECTION TO DB.G2.- REPLACEMENT OF CIRCUIT PROTECTION AND SUBMAIN TO DB.G2.- NEW LIGHTING, POWER AND COMMUNICATIONS TO THE SSSM
WORKSHOP EXTENSION ON LEVEL A, OFFICE ON LEVEL B AND WELDINGAREA ON THE LOWER LEVEL.
a. INSPECT THE SITE TO ASCERTAIN THE EXTENT OF EXISTINGELECTRICAL, LIGHTING AND FIRE SERVICES TO BE REMOVED TOREFER TO THE DEMOLITION PLANTO CONFIRM EXTENT OF POWER OUTLET & LIGHTINGLOCATIONS TO THE RETAINED.
b. REMOVE ALL REDUNDANT CABLING.c. PROVIDE ALL TEMPORARY POWER AND LIGHTING AS REQUIRED
THROUGHOUT THE WORKS AND IN ACCORDANCE WITH AS/NZS 3012.d. DECOMMISSION, ISOLATE, DEMOLISH AND REMOVE FROM SITE ALL
REDUNDANT CABLES AND EQUIPMENT INCLUDING MINOR ASSOCIATEDCOMPONENTS THAT BECOME REDUNDANT AS A RESULT OF THE WALLS.
e. INVESTIGATE WIRING AS WORK PROCEEDS; FOR ALL WORK WHICHENCROACHES THE DEMOLITION AREA ASCERTAIN THE ORIGIN OF THESUPPLY AND WHERE THE CABLES TERMINATE. IF THE SERVICE IS NOTCLEARLY DOCUMENTED TO BE DEMOLISHED, ADVISE THESUPERINTENDENT WHO WILL PROVIDE A DIRECTIVE AS TO WHETHERTHE DEMOLITION IS TO PROCEED AND THE CABLE IS TO BE RETAINED
a. PROVIDE NEW LIGHTING AS SPECIFIED ON THE DRAWINGS.b. ALTERNATE LIGHT FITTINGS WILL NOT BE ACCEPTED WITHOUT
APPROVAL FROM SUPERINTENDENT OR ELECTRICAL ENGINEER.PROVIDE PRODUCT SHEETS FOR ALL ALTERNATIVE FIXTURES.
c. ALL FLUORESCENT LUMINAIRES SHALL BE SUPPLIED WITH HIGHEFFICIENCY 4000 KELVIN TRIPHOSPHOR LAMPS (COLOUR 84).ALL LIGHTING CIRCUITS MODIFIED AS PART OF THESE WORKS SHALL BEPROVIDED WITH NEW RCD PROTECTION. MAXIMUM OF 30 BALLASTS /CIRCUIT.
d. INSPECT EXISTING DISTRIBUTION BOARDS TO DETERMINE EXISTINGRCD INSTALLATION.
e. MAXIMUM EARTH LEAKAGE CURRENT PER BALLAST SHALL BE LESSTHAN 0.3mA.
f. COORDINATE FINAL SET-OUTS FOR LIGHT FIXTURES FROM ON-SITEDIMENSIONED SETOUTS. COORDINATE ALL LUMINAIRE INSTALLATIONS
WITH CEILING SETOUTS AND
PROVIDE SWITCH CONTROLS TO ALL OF THE REFURBISHED SPACESAS NOMINATED ON THE DRAWINGS.LIGHTING TO THE WORKSHOPS AND OFFICES ARE TO BE SWITCHCONTROLLED WITH OCCUPANCY SENSOR OVERRIDE. LIGHTING ISACTIVATED VIA WALL MOUNTED SWITCHPLATES. IF NO MOVEMENT ISSENSED BY THE OCCUPANCY SENSORS WITHIN THE ACTIVATEDSPACE AFTER 30 MINUTES, THE LIGHTING SHALL SWITCH OFF.
a. PROVIDE NEW EMERGENCY AND EXIT LIGHTING WITH MINIMUMCLASSIFICATIONS AS DOCUMENTED IN THE LEGEND.
b. UTILISE THE EXISTING ACTIVE SUPPLY AT DB-LG2N TO SUPPLYEACH EMERGENCY LUMINAIRE AND EXIT SIGN ORIGINATING FROMTHE TEST SWITCH CONTROL PANEL.
c. CONNECT EMERGENCY LUMINAIRES AND EXIT SIGNS TO THE SAMELIGHTING CIRCUITS AS ADJACENT LIGHT FITTINGS.
d. ALL EMERGENCY LUMINAIRES SHALL BE TESTED TO A MINIMUM 120MINUTES AT INSTALLATION.
a. PROVIDE NEW POWER CONNECTIONS AS SHOWN ON THE DRAWINGS.
a. SUPPLY, INSTALL AND CONNECT ALL NEW POWER OUTLETS ANDACCESSORIES AS SHOWN.
c. ALL POWER OUTLETS SHALL HAVE CIRCUIT REFERENCE LABELS WITHBLACK LETTERS ON WHITE BACKGROUND FIXED BY INTEGRAL CIRCUITDESIGNATION LABEL WINDOW ON SWITCH PLATE COVER. LABELS SHALLREFER TO THE SWITCHBOARD ORIGIN AND CIRCUIT BREAKER NUMBER.NEW SWITCHBOARD LABELS SHALL SHOW ID AND ORIGIN ON INTERNALESCUTCHEON. ALSO LABEL GPO WITH PERMANENT MARKER OR OTHERMEANS WHICH SHALL BE VISIBLE WHEN COVER PLATE IS REMOVED.
d. PROVIDE AND INSTALL CIRCUIT BREAKERS INCLUDING 30mA RCDPROTECTED POWER CIRCUITS. INSPECT EXISTING CIRCUIT BREAKERSTO DETERMINE IF RCD'S HAVE BEEN INSTALLED.
e. COORDINATE OUTLETS AND CONNECTIONS TO DEDICATED EQUIPMENTWITH THE INSTALLER OF THAT EQUIPMENT.
a. SUPPLY, INSTALL AND COMMISSION NEW FIRE DETECTION AND SSIESPSPEAKERS WITHIN THE AFFECTED & NOMINATED AREAS, CONNECTED BACKTO THE EXISTING FIRE DETECTION AND WARNING SYSTEM INSTALLED WITHINTHE BUILDING.
b. MAINTAIN THE SAME FIRE ZONE FOR THE BUILDING AREAS. UPDATE THE BLOCKDIAGRAMS TO REFLECT THE NEW ROOM LAYOUT, AND NEW DETECTORLOCATIONS.
a. THE INSTALLATION BY THE CONTRACTOR SHALL BE EARTHED.b. EARTHING SHALL BE CARRIED OUT IN ACCORDANCE WITH THE
RELEVANT SUPPLY AUTHORITY REQUIREMENTS AND AS/NZS3000:2007 AND ACIF S009.
a. SUPPLY, INSTALL AND CONNECT ALL NEW POWER AND LIGHTINGNECESSARY TO COMPLETE THE INSTALLATION.
b. ALL POWER AND LIGHTING CABLES SHALL BE THERMOPLASTICINSULATED (T.P.I) AND SHEATHED (T.P.S) 0.6/1.0kV GRADE ASAPPLICABLE WITH AS 5000.1. INSULATION SHALL BE V75 GRADE UNLESSOTHERWISE NOTED.
c. LIGHTING SUB-CIRCUITS, INCLUDING EMERGENCY LIGHTING: 2.5mm²MIN.
d. GENERAL PURPOSE POWER CIRCUITS: MIN 2.5mm².e. CONTROL CIRCUITS INCLUDING ALARMS, FIP, ETC: MIN 2.5mm².f. FLEXIBLE CORDS: MIN 30/0.25mm²g. SEGREGATE LV POWER CABLING AND COMMUNICATIONS/CONTROL
CABLING TO AS3000 AND S009.h. ALL CABLING AND CABLE TRAYS SHALL BE CONCEALED IN CEILING
SPACES OR WALLS UNLESS INDICATED OR APPROVED OTHERWISE.i. ALL CABLING INDICATED OR APPROVED TO NOT BE IN A CONCEALED
CEILING SPACE ARE TO BE ENCASED IN CONDUIT OR DUCT ANDSECURELY MOUNTED IN FLAT FORMATION AGAINST A WALL OR SLAB INACCORDANCE WITH AS3008.
a. CARRY OUT TESTING, OPERATING AND ADJUSTING THE SYSTEM ANDEQUIPMENT, AND FOR FULLY INSTRUCTING THE SUPERINTENDENT ORHIS REPRESENTATIVE IN THE OPERATION OF THE SYSTEM ANDEQUIPMENT. PROVIDE FULL OPERATOR'S MANUAL.
b. DEMONSTRATE TO THE SUPERINTENDENT AND NOMINATEDREPRESENTATIVES THE FULL OPERATION OF THE LIGHTING CONTROLSYSTEM (INCLUDING ALL PRESETS AND CONTROLS OUTLINED WITHINTHIS DOCUMENT AND ALL MOTION SENSOR / TIMER CONTROLSPRESCRIBED) IN ACCORDANCE WITH THE PERFORMANCEREQUIREMENTS OUTLINED ON THE DRAWINGS.
c. ALLOW TO RETURN TWICE (2) DURING THE DEFECTS LIABILITY PERIODTO ADJUST PROGRAMMING TO SUIT BUILDING OWNER/MANAGERREQUIREMENTS.
d. SUBMIT TEST REPORTS. PROVIDE THE SUPERINTENDENT WITH ALLTEST RESULTS, BOUND, FOR REVIEW. THE CERTIFICATE OF PRACTICALCOMPLETION WILL ONLY BE SIGNED AFTER THE COMPLETE TESTREPORTS HAVE BEEN REVIEWED. INCLUDE A HARD AND SOFT COPY OFTHE FULL TEST REPORTS IN THE OPERATION AND MAINTENANCEMANUALS.
e. CARRY OUT TESTING IN ACCORDANCE WITH AS 3000 CLAUSE 8.3 & 8.33MANDATORY TESTS 8.3.10. OPERATION OF RCD'S.
PROVIDE A FULL SET AND A 'DWG' (AUTOCAD LATEST VERSION) SET ONDISK OF AS-BUILT DRAWINGS, TO THE SATISFACTION OF THESUPERINTENDENT INCLUDING ALL LAYERS AS SEPERATE,WITHIN 7 DAYS OF PRACTICAL COMPLETION. THE AS-BUILT DRAWINGSSHALL COMPREHENSIVELY REFLECT DETAILS OF ALL INSTALLED SYSTEMSAND COMPONENTS, AS DETAILED IN THE SCOPE OF WORK.PROVIDE TWO SETS OF OPERATION AND MAINTENANCE MANUALS, THE AIMOF THESE BEING TO PROVIDE A DETAILED UNDERSTANDING OF THE ITEMSOF EQUIPMENT AND ITS OPERATION, AN AID FOR TRAINING OF OPERATORS,A REFERENCE FOR FAULT DIAGNOSIS AND A FRAMEWORK FORPREVENTIVE AND BREAKDOWN MAINTENANCE.
THE MANUALS SHALL INCLUDE, AS A MINIMUM:a. NAME, ADDRESS, TELEPHONE AND FACSIMILE NUMBERS OF THE MANUFACTURER AND SUPPLIER OF ITEMS OF EQUIPMENT INSTALLED, TOGETHER WITH CATALOGUE LIST NUMBERS. ALSO INCLUDE SUCH DETAILS FOR ALL CONSULTANTS AND CONTRACTORS INVOLVED IN THE
DESIGN AND CONSTRUCTION PHASES. ITEMS SHALL INCLUDE, BUT ARENOT LIMITED TO ALL LIGHT FIXTURES, SWITCHES, GPOS, DATAOUTLETS, SKIRTING AND DISTRIBUTION BOARD.
b. TECHNICAL DESCRIPTION AND MODES OF OPERATION OF THESYSTEMS INSTALLED.
c. PRODUCT LITERATURE FOR THE SYSTEMS INSTALLED AND CONTACT DETAILS FOR SUPPLIERS AND MANUFACTURERS' OF THESE SYSTEMS.d. CONTROL AND SWITCHING SEQUENCES AND FLOW DIAGRAMS FOR SYSTEMS INSTALLED, INCLUDING SAFETY FEATURES. ALSO PROCEDURES FOR OPERATING AND ADJUSTING CONTROL SYSTEMS.e. MANUFACTURERS' OPERATIONAL AND SAFETY LITERATURE, AS APPROPRIATE.f. EMERGENCY MAINTENANCE PROCEDURES, INCLUDING TELEPHONE NUMBERS FOR EMERGENCY SERVICES, AND AFTER HOURS CONTACTS FOR SUPPIERS AND CONTRACTORS AND PROCEDURES FOR FAULT FINDING.g. STATUTORY CERTIFICATES OF COMPLIANCE FOR ALL ELECTRICAL AND COMMUNICATIONS WORK, COPIES OF MANUFACTURERS' WARRANTIES, CERTIFICATES FROM AUTHORITIES AND UTILITIES, PRODUCT CERTIFICATION, COPIES OF TEST CERTIFICATES, ETC.h. AS-BUILT DRAWINGS, SHOP DRAWINGS, SYSTEM SCHEMATICS ETC.i. COMMISSIONING RECORDS.
UNDAMAGED.
b. AS PART OF THE DEMOLITION & REFURBISHMENT WORKS, A NEW MAIN SITCHBOARD IS TO BE PROVIDED. SUPPLY & INSTALL A NEW BOARD ON THE LOCATIONS AS SHOWN ON THE DRAWINGS.
c. ALLOW TO LOCATE THE PATH OF THE FOLLOWING SUBMAINS: - INCOMING CONTROL MAINS - POWER SUPPLIES TO EXISITING SPOTLIGHTING - SUBMAINS TO SEWER PUMPS & RELOCATE & TERMINATE INTO NEW DB LOCATION IT IS ANTICIPATED THERE IS SUFFICIENT LENGTH ON ALL SUBMAINS, WITH THE EXCEPTION OF THE NORTHERN SPORTSFIELD
d. AS PART OF THE SCOPE, RELOCATE THE CONTROLS FOR THE SEWER PUMPS ADJACENT TO THE NEW DB. RE-CONNECT SUBMAINS & CONTROLSTO THIS LOCATION.
e. RELOCATE EXISTING CONTROLS CUBICLE FOR SPORTS LIGHTING & MOUNT ADJACENT TO NEW DB. ALLOW TO REMOVE ANY EXISTING RELAYS, BUTTONS & INDICATOR LAMPS & RECONNECT INTO A NEW, LOCKABLE & IP RATED ENCLOSURE. ALLOW TO RE-WIRE ALL CONTROLS TO MATCH EXISTING FUNCTIONALITY.
b. WHERE EXISITING OUTLET POINTS ARE TO BE RETAINED, PROVIDE NEW OUTLETS & WIRING.
a.
b.
EMERGENCY LIGHTING
SYMBOL
LIGHTING LEGEND
DESCRIPTIONLAMP
TYPE QTY WATTAGE COLOUR TEMP.MOUNTING ARRANGEMENT LOUVRE/ DIFFUSER/ REFLECTOR BALLAST EQUAL TO MANUFACTURER/ MODEL No. NOTES
SUSPENDED FLUORESCENT TROFFER
LIGHTING CONTROL
POWER ANNOTATION
10A ONE WAY LIGHT SWITCH
230V, 10A SINGLE GPO MOUNTED AT 300mm AFFL UNLESS OTHERWISE NOTED.COORDINATE ALL OUTLET LOCATIONS WITH JOINERY AND FURNITURE
F OUTLET FOR FRIDGE.
C MOUNTED WITHIN CEILING
230V, 10A DOUBLE DOUBLE GPO MOUNTED AT 300mm AFFL UNLESS OTHERWISENOTED. COORDINATE ALL OUTLET LOCATIONS WITH JOINERY AND FURNITURE.
SURFACE MOUNTED EMERGENCY LUMINAIRE EQUAL TO CLEVERTRONICLIFE LIGHT CLASSIFICATION C0=D32, C90=D32.
EMERGENCY EXIT LUMINAIRE. ARROWS INDICATE DIRECTION OFTRAVEL EQUAL TO CLEVERTRONICS CIRCUIT.
EM1
EX1DISTRIBUTION BOARD - EXISTING
HTR OVERHEAD HEATER. REFER TO MECHANICAL DRAWINGS
NOTES:1. ELECTRICAL CONTRACTOR TO TEST AND TAG ALL
APPLIANCES. REFER APPLIANCE CONTRACT.
NEW 63A THREE PHASE SWITCHED SOCKET OUTLET. OUTLET EQUAL TO CLIPSAL66CY463 COLOUR ORANGE.
TP 63A
FIRE PROTECTIONFIRE INDICATOR PANEL - EXISTING
SMOKE DETECTOR - NEW
RECESSED CEILING MOUNTED SPEAKER - NEW
FIP
THERMAL DETECTOR - NEW
E EXISTING OUTLET TO REMAIN
WP
AB ABOVE BENCH. 100mm ABOVE BENCH.
SP
WS WORKSTATION. 300mm AFFL.WEATHERPROOF. 300mm AFFL.
SINGLE PHASE.
10A TWO WAY LIGHT SWITCH
TP TRIPLE PHASE.
LED 1 50 4000K CHAIN SUSPENSION TO 1500 AFFL ACRYLIC DIFFUSER ELECTRONIC THORN COLLEGE LED CAT. NO. COLLEGE LED 3700-840L1200 PC CL.
POWDER COATED WHITE SHEET STEEL BODYS1
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
14/02/2017 10:35:57 AM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-E001
J. LUCAS C. HEINRICH
D. BELL*
D. BELL*
SPECIFICATION & LEGEND10.02.17
J. DAVID*
JD JL* DB*
ELECTRICAL
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
UP
E
D
XX1 XX5XX2 XX3 XX4
EQ.50
150A
+0 RL
WP WP WP WP
WPWPWP63A TPWP
N2WP
+0 RL
WP
WP
EXISTING DB-G2
151A
WORKSHOP 119A100
WA-01
WA-E
N1.
POWER NOTES - LEVEL ARETAIN EXISTING POWER TO AIR COMPRESSOR
N2. PLUG TYPE TO MATCH PLUG ON MILLINGMACHINE TO BE INSTALLED COORDINATEWITH ASC ON MODEL & MAKE OF THEMACHINE
N3. ALL NEW CIRCUITS SHALL BE PROTECTEDWITH NEW QUICK LAG RCBOS, AS REQUIREDBY AS/NZS 3000
N4. MAINTAINTHE EXISTING DB.G2. THIS DB IS TOBE ISOLATED, DISCONNECTED ANDREMOVED TO MAKE WAY FOR A NEW DB.G2DURING THE WORKS, INCLUDING NEWSUBMAINS AND CIRCUIT PROTECTION ATTHE MSB.
XX1 XX5XX2 XX3 XX4
RA-RB1LOCATION OFEQ.50 - NEW MILL
ROOF SAFETY MESH,INSULATION & STRUCTURESEXPOSED TO VIEW
@ 3156 FROMLEVEL 1 FFL
BR-BR1
PU
RA-RB1
N1
EM1S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1S1
DB.G2. NOTE D4
19A37
MSB
DBG1
WORKSHOP 5
WORKSHOP 6WORKSHOP 4
19A43
19A105
19A9319A104
MSB - EXT
SSSM HALL
PROPOSEDWORKSHOP 1
19A100
Sim1
19-E200
MAINRECEPTION
STAFF ENTRY
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
14/02/2017 10:35:22 AM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-E200
J. LUCAS C. HEINRICH
D. BELL*
D. BELL*
POWER & COMMS LEVEL A & LOWER GROUND10.02.17
J. DAVID*
JD JL* DB*
ELECTRICAL
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 50POWER & COMMS LAYOUT
0
SCALE 1: AT ORIGINAL SIZE
1000 2000 3000 4000 5000 mm
100
N
SCALE 1 : 50RCP - LIGHTING LAYOUT
CB47DB-62
CB22-24DB-G2
CB21DB-62
CB7DB-G2
KEYNOTE LEGEND
KEYNOTE DESCRIPTIONBR-BR1 ROOF BRACING-16dia ROD + TURNBUCKLE. REFER
STRUCTURAL DWGS.EM1 EMERGENCY LIGHTING ON RAFTERSPU PURLIN-Z10012 @ 1200crs LAPPED 900.MIDSPAN
BRIDGING. REFER STRUCTURAL DWGS..RA-RB1 STEEL RAFTER-200UB25. REFER STRUCTURAL DWGS.S1 SUSPENDED FLUORESCENT LIGHT TROFFERWA-01 EXTERNAL WALL - LYSAGHT CUSTOM ORB CLADDING,
35mm STEEL TOP HATS, PROMINA 60 BOARD,FLETCHER TITANTUFF™ WALL WRAP WITH R2.7 90MMPINK® SONOBATTS® PREMIUM, 92mm STEEL STUDFRAMING, 9mm CSR CEMINTEL FIBRE CEMENT WALLPANELS.
WA-E EXISTING COLORBOND CUSTOM ORB CLAD TIMBERSTUD FRAMED EXTERNAL WALL
SCALE 1 : 200ELECTRICAL POWER DEMOLITION PLAN - LEVEL A
BLK 26 SEC 8 BRUCE
PLUMBING PLAN APPROVEDDESIGNED IN ACCORDANCE WITH AS3500
SEWERAGE AND WATER SUPPLY REGULATIONS.APPROVED UNDER REGULATION 7 OF THE CANBERRADATE.........................................................................
REGISTRATION No......................................................
APPROVED.................................................................
SERVICE LOCATION MATERIAL nom. SIZE (mm) COMMENTSPIPEWORK MATERIALS SCHEDULE
DRAWINGS
LEVELS
REGULATIONS
TESTING AND INSPECTION
MEASUREMENTS
EXISTING SERVICES
FIRE RATED PENETRATIONS
PIPE DIAMETERS
THERMAL INSULATION OF PIPEWORK
ACOUSTIC SEPARATION OF PIPEWORK
MARKING SERVICES
GENERAL
GENERAL NOTES
OCCUPATIONAL HEALTH AND SAFETY
ABBREVIATIONS
CWXX
LEGENDNEW COLD WATER PLUMBINGNEW HOT WATER PLUMBING
EXISTING COLD WATER PLUMBINGEXISTING HOT WATER PLUMBING
EXISTING SANITARY DRAIN
NEW VENT PIPENEW SANITARY DRAIN
NEW CONTROLLED TEMP. HOT WATER PLUMBING
REDUNDANT SERVICE
SYMBOLS
VALVE SYMBOLS
SIGNAGE INDICATORS
DRAINAGE SYMBOLS
BALL VALVE (NORMALLY OPEN)DOUBLE CHECK VALVENON-RETURN VALVECOLD WATER FIXTURE CONNECTIONHOT & COLD WATER FIXTURE CONNECTION
PIPE CONTINUATIONFLOW DIRECTIONELBOW (PIPE OFFSET)CAPPED PIPE END OR CONNECTION
PUMP
AIR GAP
CONTINUATION
HOSE TAP
SERVICE FLOW INDICATORSERVICE ABBREVIATIONNOMINAL DIA.SERVICE FLOW INDICATOR
THERMOSTATIC MIXING VALVEWWV
GEN01. THE DRAWINGS ARE A GUIDE ONLY FOR THE LOCATION AND LAYOUT OF THE SERVICE PIPES.GEN02. DO NOT SCALE FROM THESE DRAWINGS.GEN03. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE OTHER CONTRACT
DOCUMENTS, SPECIFICATIONS AND DRAWINGS. FOR THE FINAL LOCATION OF FIXTURES ANDFITTINGS REFER TO ARCHITECTURAL DRAWINGS.
GEN04. VERIFY THAT ALL INVERT LEVELS, SURFACE LEVELS AND CLEARANCES ARE CORRECT ANDOBTAINABLE PRIOR TO COMMENCING WORKS. IF NOT, NOTIFY SUPERINTENDENT IN WRITING,DETAILING REASONS FOR CONCERN.
GEN05. ALL LEVELS ARE SHOWN IN METRES AHD. UNO.GEN06. FULL SITE COORDINATION WITH ALL UNDERGROUND (NEW AND EXISTING) MUST BE
UNDERTAKEN PRIOR TO COMMENCEMENT OF ANY CONTRACT WORKS TO ENSURE SERVICESCAN BE LAID PROPERLY.
GEN07. ALL WORKS TO BE CONSTRUCTED IN ACCORDANCE WITH AS/NZS 3500, THE LOCAL AUTHORITYAND THE NATIONAL CONSTRUCTION CODE 2012 / PLUMBING CODE OF AUSTRALIA.
GEN08. ALL PLUMBING AND DRAINAGE MATERIALS SHALL BE IN ACCORDANCE WITH AS/NZS 3500, THELOCAL AUTHORITY AND THE NATIONAL CONSTRUCTION CODE 2012 / PLUMBING CODE OFAUSTRALIA.
GEN09. WORKS SHALL BE CONSTRUCTED BY SUITABLY QUALIFIED, COMPETENT AND LICENSED TRADESPEOPLE.
GEN10. PAY ALL COSTS FOR THE TESTING OF THE INSTALLATION AND COSTS FOR INSPECTION BYLOCAL AUTHORITY. UNO.
GEN11. UNDERTAKE ALL OF THE TESTING REQUIREMENTS OF THESE DRAWINGS, THE CONTRACTDOCUMENTS, RELEVANT CODES, STANDARDS AND LEGISLATION. UNO.
GEN12. ALL DISTANCES ARE SHOWN IN MILLIMETRES. UNO.GEN13. ALL LEVELS ARE SHOWN IN METRES. UNO.GEN14. MEASUREMENTS OF QUANTITIES ARE IN ACCORDANCE WITH AS ISO 1000:1998.
GEN15. ALL EXISTING SERVICES MADE REDUNDANT FROM THESE WORKS AND EXISTING REDUNDANTSERVICES SHALL BE REMOVED OR SEALED OFF IN ACCORDANCE WITH THESE DRAWINGS, THECONTRACT DOCUMENTS AND TO THE SATISFACTION OF THE LOCAL AUTHORITY. OBTAINRECORDS OF EXISTING SERVICES, CONFIRM LOCATION OF IN GROUND SERVICES PRIOR TOCOMMENCEMENT OF WORKS. UNDERTAKE COMPLETE AND THOROUGH INVESTIGATION BYRECORDS SEARCH AND SITE INVESTIGATION, BEFORE COMMENCING ANY WORKS.
GEN16. CONTRACTOR TO UNDERTAKE SERVICES SEARCH TO CONFIRM LOCATIONS AND COMPLETEDIAL BEFORE YOU DIG.
GEN17. PROVIDE FIRE RATED PENETRATIONS FOR SERVICES PASSING THROUGH EACH FIRE RATEDELEMENT. FIRE RATED PENETRATIONS SHALL ACHIEVE THE SAME RATING AS THE BUILDINGELEMENT PENETRATED. SEAL PENETRATIONS WITH A SYSTEM CONFORMING TO AS 4072.1.
GEN18. THE METHOD AND MATERIALS USED SHALL BE IDENTICAL WITH A PROTOTYPE ASSEMBLY FORTHE SERVICE AND BUILDING ELEMENT WHICH HAS BEEN TESTED IN ACCORDANCE WITH AS4072.1:2005 AND AS 1530.4:2005 AND HAS ACHIEVED THE REQUIRED FRL OR RESISTANCE TO THEINCIPIENT SPREAD OF FIRE OR COMPLY WITH OTHER RELEVANT PROVISIONS OF PART 3.7.1FIRE SEPARATION OF THE BUILDING CODE OF AUSTRALIA VOLUME 2. ANY PENETRATIONSCREATED OR TREATED SHALL BE PROVIDED WITH A SERVICE LABEL COMPLYING WITH AS1851:2012 CLAUSE 17.2.4.2.
PROVIDE A SCHEDULE OF ALL PENETRATIONS EITHER CREATED OR TREATED. THE SCHEDULESHALL BE SET OUT IN ACCORDANCE WITH AS 4072.1-2005, FIGURE B1 - AND SHALL BE SUITABLEFOR SUBSEQUENT USE BY THE BUILDING OWNER AS REQUIRED BY AS 1851:-2012 CLAUSE 17.4.
GEN19. WHEREVER OR WHENEVER THE PROPOSED WORKS REQUIRE THE PENETRATION OF ANELEMENT HAVING A FIRE RESISTANCE RATING, THE BUILDER SHALL ENSURE THAT ANY PERSONRESPONSIBLE FOR THE INSTALLATION OF ANY SYSTEM USED TO PROTECT/REINSTATE THE FRLOF THE PENETRATION;A. HOLDS AN APPROPRIATE LICENSEB. PROVIDES AN INSTALLATION STATEMENT IN THE FORMAT PRESCRIBED BY APPENDIX B OF
AS 4072.1 TO DESCRIBE THE PENETRATION, ITS LOCATION AND METHOD OF TREATMENT;AND
C. THE BUILDING SHALL FURNISH A COPY OF THE INSTALLATION STATEMENT AS PROVIDED IN(B) ABOVE TO THE INSPECTING OFFICER PRIOR TO REQUESTING AN INSPECTION FOR'SUBSTANTIAL COMPLETION'.
GEN20. PROVIDE ACCESS TO PASSIVE FIRE PROTECTION DEVICES FOR INSPECTION IN ACCORDANCEWITH AS 1851:2012.
GEN21. ALL PIPE DIAMETERS DETAILED ON THESE DRAWINGS ARE SHOWN AS NOMINAL DIAMETERS.GEN22. WHERE PE, PEX, PP, PB AND COMPOSITE PLASTIC PIPEWORK MATERIALS ARE NOMINATED, THE
NOMINAL DIAMETER SHALL BE TAKEN AS THE INTERNAL DIAMETER OF THE PIPEWORK AND NOTTHE OUTSIDE DIAMETER. FOR NOMINAL DIAMETERS UP TO DN50, REFER TO AS/NZS 3500.1APPENDIX J UNO.
GEN23. THERMAL INSULATION SHALL COMPLY IN ALL RESPECTS WITH AS/NZS 3500.4:2003 SECTION 8UNO.
GEN24. "KEMLAG" OR SIMILAR WILL NOT BE ACCEPTED FOR THERMAL INSULATION.GEN25. FOR INSULATED PIPING, COMPLETELY COVER THE PIPE WITH INSULATION FITTED TIGHTLY TO
THE PIPE SURFACE AND SECURED IN ACCORDANCE WITH THE MANUFACTURERSINSTRUCTIONS. IF INSULATION IS INSTALLED IN SECTIONS, BUTT THE JOINTS CLOSELYTOGETHER WITHOUT GAPS. INSTALL INSULATION SO THAT IT IS READILY REMOVABLE ATUNIONS AND COUPLERS.
GEN26. PROVIDE METAL SHEATHING TO INSULATION WHERE PIPEWORK IS IN PLANT ROOMS AND,EXTERNAL LOCATIONS. COVER PIPING WITH METAL SHEATHING SPRUNG OVER THE INSULATIONIN ONE PIECE WITH LAPS AT LEAST 30mm WIDE, AND FASTENED WITH SELF TAPPING SCREWSOR SNAP HEAD RIVETS AT 150mm MAXIMUM CENTRES. PREFORM THE SHEATHING TO MATCHTHE SHAPE OF THE INSULATED PIPE AND FITTINGS. POSITION LAPS TO AVOID WATERPENETRATION. IN EXTERNAL LOCATIONS WEATHERPROOF THE JOINTS AND FIXINGS USING ANON-SETTING MASTIC.
GEN27. ACOUSTIC SEPARATION SHALL BE PROVIDED IN ACCORDANCE WITH THE BCA. LIAISE WITH THEARCHITECT TO DETERMINE THE EXTENT AND METHOD OF SEPARATION UNO.
GN28. UNDERGROUND MARKING TAPE: TO AS/NZS 2648.1. LAY PLASTIC WARNING TAPE WITHINTEGRATED WIRE TRACE, 350mm ± 50mm ABOVE ALL BURIED PIPING, FOR THE FULL LENGTH OFTHE PIPING. COVER THE TAPE WITH APPROXIMATELY 100mm DEEP SAND.
GN29. PROVIDE TRENCH MARKER TAPE THAT CLEARLY IDENTIFIES THE SERVICE BELOW.
OHS01. FOR RESIDUAL RISKS IDENTIFIED FROM THE DESIGN PROCESS, REFER TO THE PROJECT RISKREGISTER.
OHS02. CHANGES TO HYDRAULIC SERVICES DESIGN SHALL BE REVIEWED AGAINST THE PROJECT RISKREGISTER AND MAY REQUIRE FURTHER RISK ASSESSMENT.
AFFL ABOVE FINISHED FLOOR LEVELAHD AUSTRALIAN HEIGHT DATUMAS AUSTRALIAN STANDARDB BASINCI CAST IRONCO CLEAR OUT TO SURFACE
CW COLD WATERDIA DIAMETERDN NOMINAL DIAMETERDWV DRAINAGE WASTE VENT
EX EXISTINGFFL FINISHED FLOOR LEVEL
HDPE HIGH DENSITY POLYETHYLENEHL HIGH LEVELHTVB HOSE TAP WITH VACUUM BREAKERHW HOT WATERHWU HOT WATER UNITIL INVERT LEVELIO INSPECTION OPENINGkPa KILOPASCALLL LOW LEVELNTS NOT TO SCALEPVC-U UNPLASTICISED POLYVINVL CHLORIDERL RELATIVE LEVELSHR SHOWERSK SINKTD TUNDISH
UNO UNLESS NOTED OTHERWISEWC WATER CLOSET
FIRE FIGHTING PURPOSES
NON-POTABLE
POTABLE
RAINWATER OUTLET
SAFETY SHOWER EYE WASH
'P' TRAP'S' TRAPTUNDISH
GN30. PROVIDE IDENTIFICATION LABELS TO ALL PIPEWORK WITH INDICATORS SHOWING FLUID FLOWDIRECTION.
(E)HW(E)W
FW FLOOR WASTE
NEW HOT WATER RETURN PLUMBING
GD GRATED DRAIN
WWV WATER WATER VALVE
TD/AC TUNDISH AIR/CONDITIONERTD/HWS TUNDISH HOT WATER SYSTEM
FWG FLOOR WASTE GULLY
eFHR EXISTING FIRE HOSE REEL
CTW CONTROLLED TEMPERATURE WATER
DESIGNATION FE1 FE2FIRE EXTINGUISHERS SCHEDULE
LOCATION GENERAL - REFER TO DRAWINGS ALL LOCATIONSUNIT TYPE 2.5kg DRY CHEMICAL POWDER CLASS AB(E) 4.5kg DRY CHEMICAL POWDER CLASS AB(E)CLASSIFICATION & RATING 3A:40B:(E) 4A:60B:(E)
STORMWATER DRAINAGE IN-GROUND uPVC TO AS/NZS 1260 100-225 SOLVENT WELDEDSTORMWATER DRAINAGE IN-GROUND uPVC TO AS/NZS 1342 300-375 RUBBER RING JOINTEDCOLD WATER ABOVE GROUND COPPER TO AS1432 15-100 TYPE 'B', BRAZEDSTORMWATER DRAINAGE ABOVE GROUND 25-50 TYPE 'B', LABEL TO AS1234COPPER TO AS1432
SSEW
RW
P
NP
FFPNEW POTABLE WATER SUPPLYCWNEW STORMWATER LINESWEXISTING STORMWATER LINEEX SWNEW SPRINKLER BRANCHSPB
FHR (PLAN)
NEW PIT 1
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
N.T.S.
14/02/2017 11:06:31 AM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-H001
J. LUCAS S. WILSON
D. BELL*
D. BELL*
LEGEND & GENERAL NOTES10.02.17
J. DAVID*
JD JL* DB*
HYDRAULIC
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
UP
GYMNASTICS PIT
225
IL 610.81
IL 610.81
EXISTINGJOINT OF 100SEEPAGE TO100 V.CSTORMWATER
EXISTING 150OUTLET TO DOORTRACKS. I.L 610.71TYP
EXISTING 225 R.C CLASSX STORMWATERGRADE 1% TO BE MADEREDUNDANT
EXISTING 900 x 900CAST IN SITUCONCRETE
STORMWATER PIT TOBE DEMOLISHED
IL 610.45IL 610.35
IL 610.58
EXISTING CONCRETESTORMWATER PIT UNDERCONCRETE STEPS TO BE
DEMOLISHED.
IL 610.31
EX S
W
EX SW
EX S
W
EX SW
EX S
W
EXISTING 150 DOWNPIPETO REMAIN
EXISTING STORMWATER PIPE TO BECAPPED & MADE REDUNDANT WITH APURPOSE MADE WATERTIGHTFITTING. CO-ORDINATE WITHSTRUCTURAL FOOTINGS
EXISTING STORMWATER LINETO BE MADE REDUNDANT
+ 0 RL
ALL REDUNDANT PLUMBING ONSITE IS TO BE REMOVED AND SITETO BE FILLED WITH COMPACTED
FILL TO STRUCTURAL ENGINEER'SDETAIL
GYMN
ASTIC
S PI
T
IL 610.58
EX/IL 610.810
EX SW
SWSW
SWSW
SW
SW SW SW SW
EX S
W
+ 0 RL
MAKE CONNECTION OFEXISTING SEEPAGE LINETO NEW SEEPAGE LINE
PROVIDE NEW 100mmHDPE SEEPAGE LINE.ENCASE IN CLEAN FILL &WITH WARNING TAPELAID OVER.
PROVIDE NEW 160mmHDPE STORMWATER.PIPELINE AT HIGH LEVELTO UNDERSIDE OFROOF. JOINTS TO BEELECTROFUSION TYPE.
SWSWSW
SW
EX/IL 610.810
MAKE CONNECTIONDIRECTLY TO PIT
NEW PIT 1FSL: TBC.IL: 610.230
NEW PIT 2FSL: TBCIL: TBC
300 Upvc @1%
300 U
pvc @
1%
CW
SW
25
LOCATE & MAKE CONNECTION TOEXISTING POTABLE WATERSUPPLY PLANT ROOM. POSSIBLERE-USE OF EXISTING HIGH LEVELPVC PIPING FROM EXTERNAL TOPLANT ROOM AT THE REQUIREDLOCATION. INVESTIGATIONREQUIRED.
19A100+ 0 RL
MAKE CONNECTIONOF EXISTING SEEPAGELINE
PROVIDE A 25mm RPZDFIXED 300mm FROMFGL WITH TUNDISHINSTALLED DIRECTLYUNDER
TD
PROVIDE A 36 METREFIRE HOSE REEL.CONNECT TO EXISTINGPOTABLE WATERSUPPLY WITH FIREEXTINGUISHER
FHR
FE
FECW
CC-5
GENERAL NOTES:REFER TO ARCHITECTURAL DOCUMENTSFOR MEASURED LAYOUTS.HYDRAULIC CONTRACTOR TO CONFIRMEXACT LOCATION & SIZES OF EXISTINGSERVICES.CO-ORDINATE INSTALLATION WITH OTHERSERVICES.THESE DRAWINGS ARE NOT FORCONSTRUCTION.
1.
2.
3.
4.
NEW WORKSHOP 1ROOF AREA: 109m2
3° PITCH
DP-1DP-1
GUWA-01
RSH
LN-FD
CC-5 CONCRETE SPOON DRAIN(CC.05)DP-2DP-2
FALL
WHERE STORMWATER PIPEPENETRATES ROOF SHEETINGPROVIDE A COMPLETELYWEATHER TIGHT SEAL
DOWNPIPE CONNECTINTO BACK OFRAINWATER HEAD
PROPOSEDSTORMWATER LINE INCEILING SPACE
BOX GUTTER 600 WIDE150MIN DEPTH
DP150
FALL FALL
RAINWATER HEAD &DOWN PIPE TO MATCHEXISTING
RAINWATER HEAD &DOWN PIPE TO MATCHEXISTING
EXISTING 150 DP
DP-E
DP150
LINEAR DRAINAGE SYSTEM(LN-FD) ACROSS OPENINGS.
CONCRETE SPOONDRAIN. (CC-5) REFER TOSECTION DETAILS.
RSH
SPB
LINE OF ROOF PURLIN
SPBSPB
SPB SPBSPB
SPB SPBSPB
NEW SPRINKLER BRANCHLINE FROM EXISTING
19A100
+ 0 RL + 0 RL
FHRFE
FE
SPB
SPB
SPB
EXISTING SPRINKLER LINETO EXTERNAL
No Revision Note: * indicates signatures on original issue of drawing or last revision of drawing Drawn Job Project Date
Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose. Scale
Drawn
Drafting
Approved
Date
Check
Designer
DesignCheck
DO NOT SCALE Client
Project
Title
Original Size
A1 Drawing No: Rev:This Drawing must not beused for Construction unlesssigned as Approved
Plot Date: Cad File No:
-Level 7, 16 Marcus Clarke Street, Canberra ACT 2601 AustraliaGPO Box 1877 Canberra ACT 2601T 61 2 6113 3200 F 61 2 6113 3299E [email protected] W www.ghd.comManager Director
(Project Director)
As indicated
14/02/2017 11:38:31 AM C:\Users\jlucas\Desktop\Revit Local\23-14879_HPC SSSM Workshop Tender 1_LOCAL.rvt
AUSTRALIAN SPORTS COMMISSION
19-H400
J. LUCAS S. WILSON
D. BELL*
D. BELL*
GENERAL ARRANGEMENT10.02.17
J. DAVID*
JL JL* DB*
HYDRAULICS
0ISSUE FOR TENDER0 10.02.17
TENDER
23-15844
HPC SSSM BUILDING WORKS
SCALE 1 : 100HYDRAULIC - SITE DEMO LAYOUT
0
SCALE 1: AT ORIGINAL SIZE
500 1000 1500 2000 2500 mm
50
N
SCALE 1 : 100HYDRAULIC - SW DRAINAGE & COLD WATER LAYOUT
SCALE 1 : 50HYDRAULIC - ROOF STORMWATER DRAINAGE LAYOUT
SCALE 1 : 50HYDRAULIC - FIRE SPRINKLER LAYOUT
KEYNOTE LEGEND
KEYNOTE DESCRIPTIONCC-5 CONCRETE - CONCRETE MOWING STRIP/SPOON
DRAIN - 600mm WIDTHDP-1 LYSAGHT COLORBOND DOWNPIPE WITH RAINWATER
HEAD-TO MATCH EXISTING SSSM BUILDINGDOWNPIPES.REFER TO HYDRAULIC ENGINEER'SDWGS FOR ALL DETAILS.
DP-2 LYSAGHT COLORBOND OVER FLOW PIPE-TO MATCHDOWNPIPE. REFER TO HYDRAULIC ENGINEER'SDWGS FOR ALL DETAILS.
F4 EXTERNAL LUMINAIREFE FIRE EXTINGUISHERFHR FIRE HOSE REELGU COLORBOND BOX GUTTER - BOX GUTTER 600mm
WIDE 150mm MIN DEPTHLN-FD STORMTECH LINEAR DRAINAGE SYSTEM -
HYDRAULIC ENGINEER TO SPECIFY DIMENSIONSRA-RB1 STEEL RAFTER-200UB25. REFER STRUCTURAL
DWGS.RA-RB2 STEEL RAFTER-150PFC. REFER STRUCTURAL DWGS.RF-SP INSULATION SPACER - FLETCHER ROOF RACKRSH LYSAGHT TRIMDEK COLORBOND ROOF SHEETSWA-01 EXTERNAL WALL - LYSAGHT CUSTOM ORB
CLADDING, 35mm STEEL TOP HATS, PROMINA 60BOARD, FLETCHER TITANTUFF™ WALL WRAP WITHR2.7 90MM PINK® SONOBATTS® PREMIUM, 92mmSTEEL STUD FRAMING, 9mm CSR CEMINTEL FIBRECEMENT WALL PANELS.
11.5
STRUCTURAL STEEL1. ALL WORKMANSHIP AND MATERIALS TO BE IN ACCORDANCE WITH AS 4100 AND AS 15542. ALL STEEL TO BE GRADE 300 TO AS 3679 UNLESS NOTED OTHERWISE:-
2.1. HOLLOW SECTIONS TO BE GRADE C350 TO AS 11632.2. PURLINS AND GIRTS TO BE GRADE G450 TO AS 13972.3. PLATES TO BE GRADE 250 TO AS 3678
3. ALL CONNECTIONS AND STIFFENER PLATES TO BE 10mm THICK U.N.O.4. ALL WELDS TO BE 6mm CONTINUOUS FILLET WELDS U.N.O.
ALL WELDING TO BE SP U.N.O. FROM E48XX (ELECTRODES) / W50X (WIRE)ALL FILLET WELDS TO BE FULL (COMPLETE) PENETRATIONALL FILLET WELDS TO BE CONTINUOUS ALL ROUND BOTH SIDES U.N.O.
5. ALL BOLTS TO BE M20 AND NO CONNECTION TO HAVE LESS THAN 2 BOLTS U.N.O.ALL BOLTS TO BE HOT DIP GALVANISED GRADE 8.8/s U.N.O.PURLIN CONNECTIONS TO BE AS PER MANUFACTURER'S SPECIFICATION U.N.O.ALL HOLDING DOWN BOLTS TO BE HOT DIP GALVANISED GRADE 8.8/s U.N.O.
6. UNLESS NOTED OTHERWISE IN THE SPECIFICATION, STRUCTURAL STEEL WHICH IS PROTECTED FROMWEATHER TO BE ABRASIVE BLAST CLEANED TO CLASS 2.5 TO AS 1627.4. TO BE PRIMED BY INTERZINC 7OR APPROVED EQUIVALENT TO 75µm DFT. ALL OTHER STRUCTURAL STEEL ITEMS TO BE FULLYGALVANISED TO AS 4680 U.N.O. ON THE DRAWINGS. REFER TO ARCHITECTURAL DETAILS FOR TOPCOATS.
7. SHOP DRAWINGS TO BE SUBMITTED IN TRIPLICATE TO THE DESIGNER FOR APPROVAL. FABRICATION NOTTO COMMENCE UNTIL APPROVAL HAS BEEN GIVEN.
8. EXAMINATION OF WELDS TO BE (INSPECTION AND TEST RECORDS TO BE SUBMITTED TO THEDESIGNER):-
-- VISUAL SCANNING TO AS 1554.1 SECTION 7 ON 100% OF WELDS-- VISUAL EXAMINATION TO AS 1554.1 SECTION 7 ON 10% OF GP WELDS AND 20% OF SP WELDS-- MAGNETIC PARTICLE EXAMINATION TO BE PERFORMED ON 1% OF GP WELDS AND 5% OF SP WELDS
AND AS NOTED ON THE DRAWINGS.-- ULTRASONIC TESTING TO BE PERFORMED ON 2.5% OF FILLET WELDS AND 10% OF BUTT WELDS
AND AS NOTED ON THE DRAWINGS. IF EXAMINATION REVEALS SUBSTANDARD WELDS, FURTHEREXAMINATION AND / OR REPAIRS SHALL BE AT THE CONTRACTOR'S EXPENSE.
9. THE FABRICATION AND ERECTION OF THE STRUCTURAL STEELWORK TO BE SUPERVISED BY ANENGINEER EXPERIENCED IN SUCH SUPERVISION TO ENSURE THAT ALL THE REQUIREMENTS OF THEDESIGN ARE MET.
10. THE SUBCONTRACTOR TO PROVIDE ALL CLEATS AND DRILL ALL HOLES NECESSARY FOR FIXING STEELELEMENTS WHETHER OR NOT DETAILED ON THE DRAWINGS.
11. SUITABLE EQUIPMENT TO BE USED DURING LOADING, TRANSPORT AND ERECTION OF STEELWORK TOAVOID DAMAGE TO THE STEELWORK FINISHES. STEELWORK STORED ON SITE TO BE PROTECTEDAGAINST CORROSION OR DETERIORATION OF PAINTED SURFACES.
12. AFTER TIGHTENING, EXPOSED FACES OF BOLTS, NUTS AND WASHERS SHALL BE PREPARED ANDCOATED AS SPECIFIED OR AS FOR ADJACENT STEELWORK.
13. THE ENDS OF ALL HOLLOW SECTIONS SHALL BE SEALED.14. ALL COLD FORMED SECTIONS TO CONFORM TO AS 1163 AND SHALL BE ROLL-FORMED FROM ZINC
COATED HIGH STRENGTH STEEL, ZINC-HIGH-TEN MINIMUM YIELD STRESS 450 MPa, 350 g/m² MINIMUMCOATING MASS UNLESS NOTED OTHERWISE ON DRAWINGS. ALL PURLINS AND GIRTS AND BRIDGING TOBE LYSAGHT OR APPROVED EQUIVALENT.
15. ALL CASES OF DAMAGE TO THE PROTECTIVE COATING OF STEELWORK SHALL BE BROUGHT TO THEATTENTION OF THE DESIGNER. WITH THE DESIGNER'S APPROVAL MINOR DAMAGE MAY BE REPAIRED ASFOLLOWS:-
MECHANICALLY GRIND SURFACE TO ACHIEVE SMOOTH AND BRIGHT METAL COMPARABLE TO CLASS 2½. APPLY ZINC RICH PRIMER TO A DRY FILM THICKNESS AS PER SPECIFICATION REQUIREMENTS.
16. ABBREVIATIONS:-CFW - CONTINUOUS FILLET WELDFSBW - FULL PENETRATION BUTT WELDPPBW - PARTIAL PENETRATION BUTT WELD
17. THE LOCATION OF ALL EXISTING ELEMENTS SHALL BE SITE MEASURED PRIOR TO THE PREPARATION OFSHOP DRAWINGS.
18. ALL REACTIONS ARE SHOWN IN kN UNLESS OTHERWISE NOTED.19. SERVICES AND CEILINGS SHALL BE SUSPENDED FROM PURLIN WEBS ONLY. SUSPENDED FROM BOTTOM
FLANGES IS NOT PERMITTED.20. THE SUBCONTRACTOR SHALL HAVE SAMPLE BOLTS TESTED TO DESTRUCTION IN ACCORDANCE WITH
THE SPECIFICATION.21. WIRE HANG HORIZONTAL BRACING FROM PURLINS AT MIDPAN.
GENERAL1. ALL MATERIALS AND WORKMANSHIP TO BE IN ACCORDANCE WITH THE RELEVANT AND CURRENT S.A.A.
CODES AND WITH THE BY-LAWS AND ORDINANCES OF THE RELEVANT BUILDING AUTHORITIES.2. SETTING-OUT DIMENSIONS AND SIZES OF STRUCTURAL MEMBERS NOT TO BE OBTAINED BY SCALING
THE STRUCTURAL DRAWINGS. ANY SETTING-OUT DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGSTO BE CHECKED BY THE CONTRACTOR BEFORE CONSTRUCTION COMMENCES. REFER ANYDISCREPANCY TO THE DESIGNER BEFORE PROCEEDING WITH THE WORK.
3. DURING CONSTRUCTION IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE STRUCTUREIS MAINTAINED IN A SAFE AND STABLE CONDITION AND NO PART IS OVERSTRESSED. TEMPORARYBRACING TO BE PROVIDED BY THE CONTRACTOR AS REQUIRED TO KEEP THE WORKS AND EXCAVATIONSTABLE AT ALL TIMES.
4. UNLESS NOTED OTHERWISE, ALL LEVELS ARE IN METRES AND ALL DIMENSIONS ARE IN MILLIMETRES.5. THE STRUCTURAL COMPONENTS DETAILED ON THESE DRAWINGS HAVE BEEN DESIGNED IN
ACCORDANCE WITH THE RELEVANT S.A.A. CODES AND BUILDING CODE OF AUSTRALIA FOR THEFOLLOWING LOADINGS:-
WIND LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS 1170.2 BASED UPON A BASIC WIND VELOCITY OF 46m/s (VR) AND TERRAIN CATEGORY 3.EARTHQUAKE LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS 1170.4
6. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE CURRENT CODES OFPRACTICE EXCEPT WHERE VARIED BY THE SPECIFICATION AND / OR DRAWINGS.AS 3600 CONCRETE STRUCTURES CODEAS 4671 STEEL REINFORCING MATERIALSAS 4100 STEEL STRUCTURES CODEAS 1302 STEEL REINFORCING BARS FOR CONCRETEAS 1163 STRUCTURAL STEEL HOLLOW SECTIONSAS 1554 PART 1 WELDING OF STEEL STRUCTURESAS 1720.1 TIMBER ENGINEERING CODEAS 1289 METHODS OF TESTING SOILS FOR ENGINEERING PURPOSESAS 3700 MASONRY CODEAS 3798 GUIDELINES FOR EARTHWORKS FOR COMMERCIAL AND RESIDENTIAL
DEVELOPMENTSAS 3610 FORMWORK FOR CONCRETE
ELEMENT LIVE LOAD (kPa)
SLAB ON GROUND 10.0
NON TRAFFICABLE ROOF 0.25
FOUNDATIONS1. FOOTINGS HAVE BEEN DESIGNED FOR AN ALLOWABLE BEARING INTENSITY OF 100 kPa.
FOUNDATION MATERIAL TO BE APPROVED FOR THIS PRESSURE BY THE CONTRACTOR'S GEOTECHNICALENGINEER BEFORE REINFORCEMENT AND / OR CONCRETE ARE PLACED.
2. FOOTINGS TO BE LOCATED CENTRALLY UNDER WALLS AND COLUMNS UNLESS NOTED OTHERWISE.3. RETAINING WALLS (OTHER THAN CANTILEVER WALLS) NOT TO BE BACKFILLED UNTIL FLOOR
CONSTRUCTION AT TOP AND BOTTOM IS COMPLETED. ENSURE FREE DRAINING BACKFILL IS USED ANDDRAINAGE IS IN PLACE. CANTILEVER WALLS TO BE BACKFILLED ONLY AFTER MINIMUM CONCRETESTRENGTH IS ACHIEVED.
4. BLINDING CONCRETE TO BE PLACED ON THE SAME DAY AS THE FINAL EXCAVATION TO THE FOUNDATIONDESIGN LEVEL.
5. FOOTING LEVELS WHERE SHOWN ARE ESTIMATES ONLY AND WILL BE ESTABLISHED DURING SITEINSPECTION.
6. UNLESS OTHERWISE APPROVED BY THE SUPERINTENDENT / ENGINEER THE LIMITATIONS OFEXCAVATIONS NEAR FOOTINGS SHALL BE AS FOLLOWS:-
7. SUB GRADE AND SUB BASE FOR SLABS ON GROUND SHALL COMPLY WITH THE FOLLOWING:-
SUB GRADE:UNLESS OTHERWISE SPECIFIED THE SUB GRADE BELOW BASE COURSES FOR SLABS SHALL BE SUITABLEMATERIAL COMPACTED TO 95% OF MAXIMUM DRY DENSITY DETERMINED BY TEST AS 1289-E 2.1 OR 65% MINIMUM DENSITY INDEX FOR COHESIONLESS SOILS.BASE:BASE SHALL BE APPROVED WELL GRADED NATURAL GRAVEL OR CRUSHED ROCK (MAX. SIZE 40mm) SPREAD AND COMPACTED TO 98% OF MAXIMUM DRY DENSITY DETERMINED BY TEST AS 1289-E 2.1 OR 80% MINIMUM DENSITY INDEX FOR COHESIONLESS SOILS.
8. ALL FREE DRAINING GRANULAR FILL MATERIAL BEHIND RETAINING WALLS SHALL BE OF STRONGDURABLE PARTICLES CONFORMING TO THE FOLLOWING GRADINGS:-
AS SIEVE SIZE % PASSING53mm 1009.5mm 45-1002.36mm 20-75600µm 10-2075µm <15
9. WHERE SELECT FILL IS SHOWN ON THE DRAWINGS, FILL SHALL COMPLY WITH THE FOLLOWING:-9.1 REMOVE TOPSOIL (IF ANY) AND EXISTING FILL.9.2 COMPACT SURFACE TO 95% MMDD9.3 PLACE FILL IN MAX. 150 THICK LAYERS, EACH LAYER COMPACTED TO 95% MMDD9.4 FILL TO COMPLY WITH:-
- MAX. PARTICLE SIZE 75mm- PERCENTAGE PASSING 0.075mm SIEVE 25% MAX.- PLASTICITY INDEX NOT GREATER THAN 15% AND NOT LESS THAN 2%- MINIMUM SOAKED CBR TO BE 15%
BACKFILLED TRENCHOR OTHER EXCAVATIONCRITICAL LINE
FOOTING EXCAVATION
SLAB
BASE
NATURAL GROUND OR COMPACTED FILL - SUB GRADE
CONCRETE1. ALL WORKMANSHIP AND MATERIALS TO BE IN ACCORDANCE WITH AS 3600 AND THE CONCRETE
SPECIFICATION.2. CONCRETE QUALITY:-
MINIMUM CEMENT CONTENT = 270 kg/m³ MAX. W/C RATIO = 0.5PROJECT CONTROL TESTING TO BE CARRIED OUT IN ACCORDANCE WITH AS 3600
3. NO ADMIXTURES TO BE USED IN CONCRETE UNLESS APPROVED IN WRITING.4. CONCRETE DIMENSIONS SHOWN DO NOT INCLUDE THICKNESSES OF APPLIED FINISHES.5. DEPTHS OF BEAMS ARE GIVEN FIRST AND INCLUDE SLAB THICKNESS U.N.O.6. ALL EXPOSED EDGES AND CORNERS TO BE PROVIDED WITH 25mm FILLETS OR CHAMFERS. MAINTAIN
COVER TO REINFORCEMENT AT THESE DETAILS UNLESS OTHERWISE INDICATED.7. NO HOLES, CHASES OR EMBEDMENT OF PIPES, OTHER THAN THOSE SHOWN ON THE STRUCTURAL
DRAWINGS, TO BE MADE IN CONCRETE MEMBERS WITHOUT THE PRIOR WRITTEN APPROVAL OF THESUPERINTENDENT.
8. CONSTRUCTION JOINTS WHERE NOT SHOWN TO BE LOCATED TO THE APPROVAL OF THESUPERINTENDENT. DETAILS OF CONSTRUCTION JOINTS TO BE SUBMITTED TO THE SUPERINTENDENTFOR APPROVAL.
9. THE FINISHED CONCRETE TO BE A DENSE HOMOGENEOUS MASS, COMPLETELY FILLING THE FORMWORK,THOROUGHLY EMBEDDING THE REINFORCEMENT AND FREE OF STONE POCKETS. ALL CONCRETEINCLUDING SLABS ON GROUND AND FOOTINGS, TO BE COMPACTED WITH MECHANICAL VIBRATORS.
10. CURING OF ALL CONCRETE TO BE ACHIEVED BY KEEPING SURFACES CONTINUOUSLY WET FOR A PERIODOF 3 DAYS, AND PREVENTION OF LOSS OF MOISTURE FOR A TOTAL OF 7 DAYS FOLLOWED BY A GRADUALDRYING OUT. APPROVED SPRAYED OR CURING COMPOUNDS MAY BE USED WHERE COMPATIBLE WITHFLOOR FINISHES. POLYTHENE SHEETING OR WET HESSIAN MAY BE USED IF PROTECTED FROM WINDAND TRAFFIC.
11. CONSTRUCTION SUPPORT PROPPING TO BE LEFT IN PLACE WHERE NEEDED TO AVOID OVERSTRESSINGTHE STRUCTURE DUE TO CONSTRUCTION LOADING.
12. CONDUITS, PIPES ETC. ONLY TO BE LOCATED AS SHOWN IN THE DRAWINGS OR AS APPROVED BY THESUPERINTENDENT.
13. ALL FORMWORK AND PROPPING UNDER SUSPENDED CONCRETE WORKS SHALL BE SHALL BE REMOVEDBEFORE ANY MASONRY WORK IS BUILT ABOVE.
14. CAMBERS, UNLESS NOTED OTHERWISE ON THE DRAWINGS AND EXCEPT FOR PRESTRESSED WORKSHALL BE PROVIDED IN BEAMS AND SLABS AS FOLLOWS:-
i) SPANS - 0.002 x SPANii) CANTILEVERS - 0.004 x CANTILEVER LENGTH
CAMBERS SHALL BE CHECKED BEFORE AND AFTER DEPROPPING TO DETERMINE THE DEFLECTION OF THE MEMBERS UNDER THEIR SELF WEIGHT. PROVISION SHALL BE MADE IN THE FORMWORK SYSTEM FOR THE STRUCTURAL ENGINEER TO VARY THE SPECIFIED CAMBERS ON THE BASIS OF THIS INFORMATION. THE TOP SURFACE OF A CAMBERED MEMBER SHALL BE FINISHED TO MAINTAIN THE SPECIFIED DEPTH OF THE MEMBER.
15. SHRINKAGEMAXIMUM DRYING SHRINKAGE STRAIN MEASURED IN ACCORDANCE WITH AS 1012-PART 13 SHALL NOT EXCEED 650 x 10-6 AT 8 WEEKS. UNDERTAKE TESTING (IE. SHRINKAGE BARS) TO DEMONSTRATE COMPLIANCE WITH THIS REQUIREMENT FOR ALL SUSPENDED CONCRETE ELEMENTS.
16. BACKPROPPING FOR FORMWORK TO BE DESIGNED IN ACCORDANCE WITH AS 3610 AND CERTIFIED BYENGINEER ENGAGED BY THE SUBCONTRACTOR.
17. THE STRUCTURAL DESIGN FOR SUSPENDED STRUCTURES ASSUMES:-1. A MAXIMUM COMBINED VERTICAL DEFLECTION OF FORMWORK AND PROPS OF 2mm UNDER THE WEIGHT OF CONCRETE, REINFORCEMENT AND CONSTRUCTION LIVE LOAD.2. REMOVAL OF FORMWORK AND PROPS SHALL COMPLY WITH CLAUSE 19.6.2 OF AS 3600
ELEMENT SLUMP MAX. SIZEAGGREGATE CEMENT TYPE CONCRETE
GRADEFOUNDATIONS 80 20 GP 32 MPa
FLOOR SLABS 80 20 GP 32 MPa
MASS CONCRETE 80 20 GP 15 MPa
REINFORCEMENT1. CLEAR CONCRETE COVER TO ALL REINFORCEMENT TO BE AS FOLLOWS, UNLESS NOTED OTHERWISE.
2. ALL REINFORCEMENT TO BE FIRMLY SUPPORTED NOT GREATER THAN 1m CENTRES BOTH WAYS,UNLESS NOTED OTHERWISE. BARS TO BE TIED AT ALTERNATE INTERSECTIONS.
3. REINFORCEMENT SYMBOLS:-N - DENOTES GRADE 500 DEFORMED BARS TO AS 4671Y - DENOTES GRADE 400 Y BARS TO AS 1302 GRADE Y (TEMPCORE).R - DENOTES GRADE 250 HOT ROLLED PLAIN BARS TO AS 1302SL, RL - DENOTES FABRIC TO AS 4671 (GRADE 500)F - DENOTES GRADE 450 F HARD-DRAWN WIRE REINFORCING FABRIC TO AS 1304W - DENOTES GRADE 450 W HARD-DRAWN PLAIN WIRE TO AS 130317N20-250 means:-17 - NUMBER OF BARS IN GROUPN - BAR GRADE AND TYPE20 - NOMINAL BAR SIZE IN mm250 - SPACING IN mm
THE FIGURE FOLLOWING THE FABRIC SYMBOL SL IS THE REFERENCE NUMBER FOR FABRIC TO AS 13044. REINFORCEMENT BARS TO BE LAID IN LAYERS TAGGED ON PLANS AS FOLLOWS:-
(1) - DENOTES BARS LAID IN BOTTOM LAYER FIRST.(2) - DENOTES BARS LAID IN BOTTOM LAYER SECOND.(3) - DENOTES BARS LAID IN TOP LAYER FIRST.(4) - DENOTES BARS LAID IN TOP LAYER LAST.
REINFORCEMENT IS REPRESENTED DIAGRAMATICALLY AND NOT NECESSARILY IN TRUE PROJECTION.5. SPLICES IN REINFORCEMENT TO BE MADE ONLY IN POSITION SHOWN, OR OTHERWISE APPROVED IN
WRITING BY THE SUPERINTENDENT / DESIGNER. HOOKS, LAPS, SPLICES AND BENDS TO BE INACCORDANCE WITH AS 3600.LAPS TO BE NOT LESS THAN THE DEVELOPMENT LENGTH FOR EACH BAR SHOWN BELOW U.N.O.
6. WELDING OR REINFORCEMENT NOT TO BE PERMITTED UNLESS SHOWN ON THE STRUCTURAL DRAWINGSOR APPROVED BY THE DESIGNER.
7. JOGGLES TO BARS TO BE 1 BAR DIAMETER OVER A LENGTH OF 12 BAR DIAMETERSU.N.O.8. FABRIC TO BE LAPPED 2 TRANSVERSE WIRES PLUS 50mm. BUNDLED BARS TO BE TIED TOGETHER AT 30
BAR DIAMETER CENTRES WITH 3 WRAPS OF TIE WIRE.9. AT PENETRATIONS IN SLABS, UNLESS OTHERWISE DETAILED, REINFORCEMENT NOT TO BE CUT BUT TO
BE GATHERED EQUALLY TO EACH SIDE OF PENETRATION AND EXTRA REINFORCEMENT PROVIDEDBETWEEN THE PENETRATIONS AS DIRECTED BY THE SUPERINTENDENT.
10. DISTRIBUTION BARS TO MAIN REINFORCEMENT IN SLABS SHALL BE N12-300crs. U.N.O.11. NOTIFY AND PROVIDE ACCESS TO THE ELECTRICAL SUBCONTRACTOR TO CONNECT EARTHING.
ELEMENT COVER (mm) - NOTEXPOSED TO WEATHER
COVER (mm) - EXPOSED TOWEATHER
FLOOR SLABS ON GROUND 20 30
FLOOR BEAMS 30 40
BAR SIZE (mm) SPLICE LENGTH (mm)
N12 475N16 625N20 800N24 950N28 1250N32 1575
FORMWORK1. THE DESIGN, CERTIFICATION, CONSTRUCTION AND PERFORMANCE OF THE FORMWORK AND
FALSEWORK IS THE RESPONSIBILITY OF THE SUBCONTRACTOR. DESIGN AND CONSTRUCTION OFFORMWORK TO BE IN ACCORDANCE WITH AS 3610 UNLESS OTHERWISE APPROVED IN WRITNG BY THEDESIGNER.
MISCELLANEOUS1. NO PENETRATIONS OR CHASES SHALL BE MADE IN MASONRY WALLS OR OTHER STRUCTURE WITHOUT
APPROVAL OF THE STRUCTURAL ENGINEER.
DRAWING LIST
DRAWING NUMBER DRAWING TITLE
23-15844-S001 GENERAL NOTES23-15844-S002 FLOOR PLAN AND ROOF STEELWORK PLAN
AND ELEVATIONS23-15844-S003 FLOOR SLAB DETAILS23-15844-S004 STEELWORK DETAILS
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateDrawnRevisionNo
A1
Original Size
Title
Project
Client
Check
DesignerDrawn
Scale
Design
Conditions of Use.
This document may only be used by
GHD's client (and any other person who
GHD has agreed can use this document)
for the purpose for which it was prepared
and must not be used by any other
person or for any other purpose.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Level 7, 16 Marcus Clarke Street
Canberra ACT 2601 Australia
GPO Box 1877 Canberra ACT 2601
T 61 2 6113 3200 F 61 2 6113 3299
E [email protected] W www.ghd.com
Plot Date: Cad File No:14 February 2017 - 10:50 AM G:\23\15844\CADD\Drawings\23-15844-S001.dwg
Plotted by:
Doug Wilkinson
(Project Director)
Approved
Job
Manager
Project
Director
23-15844-S001
0
D.WILKINSON B.REMEDIOS
B.REMEDIOS* R.THOMPSON
D.BELL*
14.02.2017
NOT TO SCALE
GROUND FLOOR SLAB PLANSCALE 1:50
ROOF STEELWORK MARKING PLANSCALE 1:50
SECTIONC- 50SCALE 1 :
ELEVATIONA- 50SCALE 1 : STEELWORK SCHEDULE
MARK SIZE REMARKSRB1 200 UB 25 RAFTERSRB2 150 PFC RAFTERS
SC1 200 UB 25 COLUMNSC2 75x6 SHS COLUMNSC3 100x5 SHS STAIR COLUMNSC4 89x5 SHS COLUMNDP1 150 PFC DOOR POSTDP2 89x5 SHS DOOR POST
WS1 89x5 SHS WINDOW SUPPORTWS2 150x100x4 RHS WINDOW SUPPORTLB1 200 PFC LANDING BEAMS1 150 PFC STRUT
BR1 16Ø ROD + TURNBUCKLE ROOF BRACINGVB1 76x3.2 CHS VERTICAL BRACE
C-
A-
S1S1 S1 S1
S1 S1
RB1
RB2
RB1
RB1
RB1
S1
BR1
BR1
BR1BR1
B-
SC1SC2
SC1SC1
SC1
DP1
SC2
SC2
DP1
DP1
DP1SC4
SC4
ELEVATIONB- 50SCALE 1 :
DP1
DP1
DP1
DP1
SC4 SC
4
RB1
SC1
RB1
SC1
EXISTING OFFICE
EXISTING WORKSHOP
SC1
SC1
SC1
SC1
SC1
S1 S1 S1 S1
WS1 WS1 WS2 WS1
VB1 VB1
VB1 VB1
150 THICK CONCRETE SLAB U.N.O. ONWATERPROOF MEMBRANE ON 100mmHARDCORE ON NATURAL GROUND ORFILL AS REQUIRED. PROVIDE SL82 MESHTOP AND SL82 MESH BOTTOM WHERESHOWN.
EB1
EB1
EB1
EB1
S1S1S1
Z10012 PURLINS AT 1200crs.LAPPED 900. MIDSPAN BRIDGING
Z10012 PURLINS AT 1200crs.LAPPED 900. MIDSPAN BRIDGING
ES003
JS004
KS004
MS004
LS004
2S004
1S004
3S004
4S004
5S004
WS1 WS1 WS1
SC4
SC4
C10010 GIRTS AT 600crs.MIDSPAN BRIDGING
C10010 GIRTS AT 600crs.MIDSPAN BRIDGING
C10010 GIRTS AT 600crs.MIDSPAN BRIDGINGTYPICAL WHERE SHOWN
EA GIRT POSTS
EA GIRT POSTS
LS004
3500
4000
600 600 600600
600
600
FB1 FB1
FB1
FB1
600 THICK SLAB
LOCATION OF HEAVY MACHINERY.7.6T CNC MILL. FIXINGS AS PERSUPPLIERS DETAILS
HS003
GS003
DS003
FS003
WS1 WS1
WS1
- EXISTING GROUND TO BE COMPACTED TO 95% MMDD- HARDCORE TO BE COMPACTED TO 98% MMDD
9 OFF 90Ø x 200 DEEP POCKETS FORHOLDING DOWN BOLTS. (SET-OUT ASPER HURCO ATTACHMENT 'H')
E.J.
S.J.
S.J.
S.J.
S.J.
S.J.
S.J.
EB2
EB2
EB2
EB2
125mm EXTERNAL CONCRETE SLAB ON100mm HARDCORE ON NATURALGROUND OR FILL AS REQUIRED.PROVIDE SL82 MESH 30mm FROM TOP.
1-N16 x 1000LONG TOP
200 HIGH x 90 WIDE HOBBETWEEN DOORS
3258
EXISTING STAIRRELOCATED
EXISTING CONCRETE LANDING TO BE SAWCUT DEMOLISHED. EPOXY COAT ALLEXPOSED CUT BARS. CUT SURFACE TO BERENDERED TO ARCHITECT'S DETAILS.
JS003
200 H
IGH
x 90 H
OB
LB1
SC3
SC3
EB2
EB2
6S003
WS1 WS1
DP2
DP2
WS1
WS1
WS1 & DP2 LOCATED INLINE WITH WINDOWS
WS2
WS1
WS1
200 HIGH x 90 WIDE HOB
GRATED DRAIN ACROSS OPENINGS -ACO KLASSIKDRAIN K200 ORAPPROVED EQUIVALENT
SPOON DRAINSPOON DRAIN
NS004
PS004
PS004
ELEVATIOND- 50SCALE 1 :
D-
WS1 WS1 WS1 WS1
SC3
EXISTING COLUMNS
EXISTING TIE-BEAMS
KS003
D.J.
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateDrawnRevisionNo
A1
Original Size
Title
Project
Client
Check
DesignerDrawn
Scale
Design
Conditions of Use.
This document may only be used by
GHD's client (and any other person who
GHD has agreed can use this document)
for the purpose for which it was prepared
and must not be used by any other
person or for any other purpose.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Level 7, 16 Marcus Clarke Street
Canberra ACT 2601 Australia
GPO Box 1877 Canberra ACT 2601
T 61 2 6113 3200 F 61 2 6113 3299
E [email protected] W www.ghd.com
Plot Date: Cad File No:14 February 2017 - 10:50 AM G:\23\15844\CADD\Drawings\23-15844-S002.dwg
Plotted by:
Doug Wilkinson
(Project Director)
Approved
Job
Manager
Project
Director
23-15844-S002
0
D.WILKINSON B.REMEDIOS
B.REMEDIOS* R.THOMPSON
D.BELL*
14.02.2017
AS SHOWN
0
SCALE 1:50 AT ORIGINAL SIZE
500 2000 2500mm15001000
EXISTING BRICKRETAINING WALL
EXISTING BRICKRETAINING WALL
EXISTING WORKSHOPFLOOR SLAB
EXISTING WORKSHOPFLOOR SLAB
600
60060
0
600 300
N16-300 EACH WAYTOP & BOTTOM
MASS CONCRETEDOWN TO EXISTINGFOOTING
MASS CONCRETEDOWN TO EXISTINGFOOTING
EXISTING FOOTING
5-N16 Z-BARS INCOLUMN BASE
2-N16 -BARSADDITIONAL TOBEAM BARS
3-N16 BOTTOMR10-600 LIGS.
TYPICAL EDGEBEAM EB1 DETAIL
SECTIONES002 20SCALE 1 :
SECTIONDS002 20SCALE 1 :
SECTIONGS002 20SCALE 1 :
SECTIONHS002 20SCALE 1 :
10mm JOINTEX
10mm JOINTEX
10mm JOINTEX
TYPICAL FLOORBEAM FB1 DETAIL
600
300
3-N16 BOTTOMR10-600 LIGS.
150
150
150
EXISTING GYMNASTICSPIT VENTILATION
150
150
150
EDGE BEAM EB1REINFORCEMENT
EB1
EB1
EB1EB1FB1 FB1
FB1
150
BEAM BARS
BEAM BARS BEAM BARS
SECTIONFS002 20SCALE 1 :
150
2400
SL82 MESH BOTTOMALONG THIS SIDE
10mm JOINTEX
1000
3002 E
QUAL
RIS
ERS
SECTIONJS002 20SCALE 1 :
300
1000 300300
800
A-
SECTIONA- 20SCALE 1 :
DETAIL6S002 20SCALE 1 :
20 G
ROUT
200x200x12pl. BASEPLATE4-M12 H.D. BOLTS150 MIN. EMBEDMENT
100x100x10pl. WASHERS
N16-250 EACH WAYTOP & BOTTOM
SC3
SC3
100kPa MIN. SAFE BEARING PRESSURE
MAKE GOOD EXISTING PAVEMENT
TYPICAL EDGEBEAM EB2 DETAIL
300
300
3-L11TM BOTTOM10mm JOINTEX ALL ROUND
EXISTING STAIR STRINGER
2-M16 CHEMICAL ANCHORSTO EXISTING CLEAT. 150 MIN.EMBEDMENT
RL 611.712
SL82 MESH TOP & BOT.N12-300 BOTH WAYSWHERE SHOWN
10mm JOINTEX
10mm BACKING RODSIKASIL 728 SL ORAPPROVEDEQUIVALENT
10
EXPANSION JOINT (EJ) DETAILSAWN JOINT DETAIL
6
⅓ D
D
SCALE 1:10SCALE 1:10
FILL SAW CUT WITH SIKASIL 728 SLOR APPROVED EQUIVALENT
R20 GALVANISED DOWELS AT 300crs.GREASE AND TAPE ONE END
125
200 H
IGH
HOB
90
1-N12 HORIZONTALLAP 300 WHERE REQ'D.
N12-300 L-BARS IN HOB
10mm JOINTEX
GRATED DRAIN
EB2
600
SPOONDRAIN
10mm JOINTEX
SECTIONKS002 20SCALE 1 :
EB1
10mm JOINTEX
EB2
N20 GALVANISEDDOWELS AT 600crs.
MASSCONCRETE
N20 GALVANISEDDOWELS AT 600crs.
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateDrawnRevisionNo
A1
Original Size
Title
Project
Client
Check
DesignerDrawn
Scale
Design
Conditions of Use.
This document may only be used by
GHD's client (and any other person who
GHD has agreed can use this document)
for the purpose for which it was prepared
and must not be used by any other
person or for any other purpose.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Level 7, 16 Marcus Clarke Street
Canberra ACT 2601 Australia
GPO Box 1877 Canberra ACT 2601
T 61 2 6113 3200 F 61 2 6113 3299
E [email protected] W www.ghd.com
Plot Date: Cad File No:14 February 2017 - 10:49 AM G:\23\15844\CADD\Drawings\23-15844-S003.dwg
Plotted by:
Doug Wilkinson
(Project Director)
Approved
Job
Manager
Project
Director
23-15844-S003
0
D.WILKINSON B.REMEDIOS
B.REMEDIOS* R.THOMPSON
D.BELL*
14.02.2017
AS SHOWN
0 200 800 1000mm600400
SCALE 1:20 AT ORIGINAL SIZE
500
500
SECTIONA- 10SCALE 1 :
SECTIONJS002 10SCALE 1 :
SECTIONKS002 10SCALE 1 :
SECTIONLS002 10SCALE 1 :
A-
DETAIL1S002 10SCALE 1 :
DETAIL2S002 10SCALE 1 :
DETAIL3S002 10SCALE 1 :
DETAIL4S002 10SCALE 1 :
DETAIL5S002 10SCALE 1 :
SECTIONMS002 10SCALE 1 :
500RB1
BR1BR1
BR1BR1
RB1
RB1
SC1
RB1
BR1BR1
S1
S1S1
S1
GIRT
GIRT
VB1
VB1
SC1
WS1
SC1
SC2
RB2
SC2
RB2
SC2
S1S1
DP1
RB1
100x10 EA GIRT POSTWELDED TO DP1 POSTTYPICAL WHERE SHOWNON ELEVATION B. DRG.S002
150 PFC OUTRIGGERWELDED TO RB1.10pl. END PLATE2-M20 BOLTS TO DP1
PURLIN
10pl. FIN PLATE2-M20 BOLTS TO S1
75x10fl. CAP PLATE1-M20 BOLT + 1-M20ANCON HOLLO BOLTINSIDE SHS
10pl. FIN PLATE2-M20 BOLTS TO S1
75x10fl. CAP PLATE2-M20 BOLTS TO RB2
100
150x12fl. BASEPLATE2-M20 HOLDING DOWN BOLTS300 EMBEDMENT
20 G
ROUT
65x65x10pl. WASHERS65x65x10pl.WASHERS
150x16fl. BASEPLATE4-M20 HOLDING DOWN BOLTS300 EMBEDMENT
20 N
ON-S
HRIN
KGR
OUT
65x10fl. CLEAT WELDED TO RB1.2-M16 BOLTS TO BRACE
65x10fl. CLEATSLOTTED FOR RODBRACE - TYPICAL
10pl. STIFFENEREACH SIDE OF WEB
10pl. STIFFENEREACH SIDE OF WEB2-M20 BOLTS TO S1
100x10 EA GIRT POSTWELDED TO SC1 COLUMNTYPICAL
150x12fl. CAP PLATE4-M20 BOLTS TO RB1
150x12fl. END PLATE4-M20 BOLTS TOEXISTING UBCOLUMN FLANGE
EXISTING UBSTEEL COLUMN
EXISTING SUSPENDEDFLOOR SLAB
100x10 EA GIRT POSTWELDED TO SC2 COLUMNTYPICAL
100
10pl. END PLATE
150x90fl. FIN PLATE2-M20 BOLTS
100
6pl. CAP PLATE
90x10fl. CLEAT WELDEDINTO SLOTTED CHS.2-M20 BOLTS
10pl. GUSSET
90x10fL. CLEATWELDED TO SC1.2-M20 BOLTS
10pl. STIFFENERSEACH SIDE OF WEB
SECTIONC- 10SCALE 1 :
B-
C-
SECTIONB- 10SCALE 1 :
PLAN ON NEW STAIR LANDING
LB1
LB1
LB1
LB1
SC3
SC3
LB1
SC3
LB1
EXISTING STAIRSTRINGER
EXISTINGFLOORSLAB
10pl. END PLATE 2-M20 CHEMICALANCHORS INTO EXISTNG FLOORSLAB, CENTRALLY PLACED. 150MIN. EMBEDMENT
EXISTING STAIR
HANDRAIL TO MATCH EXISTING
WEBFORGE C253MSG LANDING PLATFORM INDICATES DIRECTION OF SPAN
10pl. CAP PLATE2-M20 8.8/TB BOLTS
WS2
WS1 WS1
WS1 CONNECTION AS FOR OTHER SIDE90x10 EA CLEATWELDED ACROSSFACE OF COLUMN.2-M20 BOLTSTHROUGH WS1
10pl. FIN PLATEWELDED TO COL.
WS2 WS2
EXISTING STAIRRELOCATED
SECTIONNS002 10SCALE 1 :
SECTIONPS002 10SCALE 1 :
RB1
150x10fl. CLEATWELDED ACROSSFACE OF SC4. 4-M16BOLTS
PURLIN
SC4
WS1
WS1
90x10 EA CLEATWELDED ACROSSFACE OF EXISTINGCOLUMN. 2-M20BOLTS THROUGH WS1
200
200
This Drawing must not be
used for Construction unless
signed as Approved
Date
Check
Drafting
DateDrawnRevisionNo
A1
Original Size
Title
Project
Client
Check
DesignerDrawn
Scale
Design
Conditions of Use.
This document may only be used by
GHD's client (and any other person who
GHD has agreed can use this document)
for the purpose for which it was prepared
and must not be used by any other
person or for any other purpose.
DO NOT SCALE
Note: * indicates signatures on original issue of drawing or last revision of drawing
Level 7, 16 Marcus Clarke Street
Canberra ACT 2601 Australia
GPO Box 1877 Canberra ACT 2601
T 61 2 6113 3200 F 61 2 6113 3299
E [email protected] W www.ghd.com
Plot Date: Cad File No:14 February 2017 - 10:48 AM G:\23\15844\CADD\Drawings\23-15844-S004.dwg
Plotted by:
Doug Wilkinson
(Project Director)
Approved
Job
Manager
Project
Director
23-15844-S004
0
D.WILKINSON B.REMEDIOS
B.REMEDIOS* R.THOMPSON
D.BELL*
14.02.2017
AS SHOWN
0 100 400 500mm300200
SCALE 1:10 AT ORIGINAL SIZE