australia’s favourite air tm 2007fujitsu is australia’s favourite air. ... the highly efficient...
TRANSCRIPT
FUJITSU GENERAL (AUST.) PTY LIMITED
A U S T R A L I A’S FA VO U R I T E A I R T M
Air Conditioning Range
2007Ducted
Cassette
Large Under Ceiling
Multi’s
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 2
2
All over Australia, Fujitsu air conditioning is being installed in some of the most innovative and unusual building applications. That’s because oursystems offer incredible design flexibility, smoother more efficient controland lower running costs.So whether you need to air condition a few rooms or a few towers, Fujitsu has the solution. No wonder it’s Australia’s Favourite Air.
If it can be designed, we can air conditio
Features
Up/Down Swing LouvreThe up/down louvre automaticallyswings up and down.
Right/Left Swing LouvreThe right/left louvre automaticallyswings in either direction.
Double Swing AutomaticComplex swing action of the louvresenables them to swing automatically inboth horizontal and vertical directions.
Automatic LouvreThe position of the louvres is setautomatically to match the operatingmode. It is also possible to adjust thelouvres using the remote control.
Auto Shut LouvreThe auto shut louvres close or openautomatically when the unit stops or starts.
Automatic Air Flow AdjustmentWhen auto mode is selected for thefan, the micro-processor adjusts the airflow to follow changes in room temperature.
Auto RestartShould there be temporary loss ofpower; the unit will automaticallyrestart itself in the same operatingmode, once the power is restored.
Auto-ChangeoverThe unit automatically switchesbetween heating and cooling modesbased on the temperature setting and room temperature.
Sleep TimerThe micro-processor gradually changesthe room temperature, allowing you tosleep comfortably at night.
Program TimerThis timer allows selection of one offour options. ON, OFF, ON ––> OFF, or OFF ––> ON.
ON-OFF TimerON-OFF timer can be set to operateonce every 24 hours.
Weekly TimerDifferent on-off times can be set for up to 7 days.
Weekly + setback TimerWeekly + Setback timer can settemperature for two time spans and foreach day of the week.
Connectable Distributing DuctConditioned air can be distributed toadjacent areas by means of adistribution duct.
Connectable Fresh Air DuctAllows introduction of fresh air to
occupied space.
Fresh air intakeFresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts).*Selected ducted units only
Control Port External inputs and outputs containedwithin the product allow on/offcontrol, fresh air interlock connectionand heater bank element connection.UTD-ECS5A* (optional parts) * Selected ducted units only.
Cooling
Heating
TESAWTop Energy Saver Award for the mostenergy efficient star rated products.www.energyallstars.gov.au
V-PAMV-Pam Inverter technology increases the maximum output of thecompressor significantly and enableshigh power and high efficiency.
I-PAMI-Pam inverter technology enables high output and high efficiencyperformance.
Soft StarterAllows economical and quietcompressor start up for conventionalmodels. Inverter control of compressorin Inverter models does not require itto have a soft starter.
Washable Panel
CPON/OFF
Soft start
C
H
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 3
3
n air condition it.
“With over 100 different brands of air conditioners on the market, how do you
know you’re choosing the right one? Well, my advice is to go with a name you can
trust, which is why I bought a Fujitsu.
No other company can match their wide range, exceptional economy and superior
efficiency. And with their famous 5 year parts and labour warranty, it’s no wonder
Fujitsu is Australia’s Favourite Air.”
Contents
ABOUT DUCTED SYSTEMS 4
INVERTER DUCTED TECHNOLOGY 5
INVERTER TYPE
DUCTED 6
CASSETTE 8
LARGE UNDER CEILING 8
MULTI’S 9
CONVENTIONAL TYPE
SLIM-LINE DUCTED 10
DUCTED 11
CASSETTE 12
LARGE UNDER CEILING 13
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 4
4
Ducted Air ConditioningThe ultimate in air conditioning
Ducted air conditioning is surely the ultimate in comfort. The Fujitsu ducted models offer quiet,
efficient operation, are easy to maintain, and operated via a wall mounted LCD control that controls
all functions of the system.
Invisible comfort
Whatever shape of the room, ducted units create
uniform temperatures throughout. The unit is
totally concealed, usually within a ceiling void.
Cool or warm air is then ducted into each room
through outlets positioned in the walls, floor or
ceiling. Easily controlled, Fujitsu’s ducted systems
provide comfort throughout your house without
leaving cool or hot spots.
The ducted air conditioning system
• Perfect comfort throughout each room
• Visually appealing
• Concealed installation
• Reverse cycle heating and cooling
• Quiet operation
• Easy-to-use LCD controller
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 5
Tem
p.
Set Temp.
Time
Temp.
Power
Tem
p.
Set Temp.
Time
Temp.
Power
On
OnOn
OffOff
CONVENTIONAL MODEL
RoomTemp.
Time
Set Temp.
Conventional
Inverter
T/2T
Room Warming Speed
DC twinrotarycompressor
Compressor COP100
90
80(%)
2 4 6 8
Cooling Capacity(kW)
COP
10 12
Comparison of cooling efficiency of DC compressor(against AC compressor)
AC Twin RotalyDC Twin Rotary
Power and Speed
INVERTER MODEL
The highly efficient DC Inverter twin rotary compressor can reach the room temperature you set up to
15% quicker than conventional models and precisely maintain temperature. The DC Inverter twin rotary
compressor makes operation at high power & high efficiency a reality. *(AOT30/36 models only)
The Inverter component allows
the outdoor unit to vary its speed
and output to match the required
capacity of the indoor unit.
Thus, the Inverter model can achieve
30% more operating efficiency than
conventional models and therefore,
is much cheaper to run.
5
Inverter Ducted TechnologyAs a world leader in energy efficient air conditioning systems, Fujitsu is committed to delivering highly
engineered inverter ducted systems. The new inverter ducted units feature an advanced scroll compressor
(AOT45/54L models only) to deliver optimum power without compromising on efficiency. Equipped with
sophisticated inverter technology, the Fujitsu inverter ducted systems are more economical to operate
and quieter to run than conventional units. The inverter component allows the outdoor unit to vary
its speed and output to match the required capacity of the indoor unit, making it up to 30% cheaper
to run than a conventional ducted system.
Fujitsu's inverter ducted air conditioning systems have been designed for easy installation in the
ceiling and roof space.
What's an inverter?
Through new, advanced technology, Inverter air conditioners are
more economical to operate and quieter to run than conventional
units. They can handle greater extremes in temperature, are
smoother and more stable in operation and reach the desired
temperature more quickly than conventional air conditioners.
Comparison of colloing efficiency of DC compressor(against AC compressor)
DC Inverter
Constant-Speed
50%Off
Approx.
Energy savings over one year
DC Inverter
Constant-Speed
Highly efficient R410A refrigerant
The R410A refrigerant, which is used in Fujitsu's Inverter ducted
systems, has zero ozone depletion potential as it contains no
chlorine. R410A also provides excellent stability and low toxity,
as well as offering superior energy saving.
Inverter control
DC twin rotary compressor*
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 6
Wired remote controller with cover
Compact high static ducted features(LUAK/UUAK)
Temperature set back timer
Group control
One remote controller can control up to 16 air conditioners.
All of the air conditioners will be operated with the same settings.
Dual remote controllers (optional)
An additional controller can be added up to the maximum of two remote
controllers. Either remote controller can control the air conditioner.
However, the timer functions cannot be used at the slave unit.
Connectable quantity: Maximum 16 indoor units for 1 remote controller
Wired remote controller Example of ducted system configuration
Indoor Outdoor
Fresh air
Heater
Indoor
SET BACK temperatureON 28°c
24°c 24°c
OFF
NORMAL temperature
40cm
125cm80cm
40cm
105cm50cm
CURRENT MODEL: 75kg NEW MODEL: 50kg
Cobalt blue heat exchanger
The outdoor unit fins are coated with a blue corrosion
resistant material to enhance durability and extend
performance life of your air conditioner.
Use this timer function to change the set temperature
in the operation times set for each day of the week.
This can be used together with other timer settings.
Commercial mode
By enabling the indoor
unit’s internal controls,
you can achieve a
continual fan operation
in the heating mode, as
required for commercial
installations.
Child lock function
Simply pressing a combination of buttons
on the standard wired remote controller,
locks and unlocks the keypad, stopping
accidental and unauthorised use.
Simplified wired remote controller (optional)
This controller can be used as an optional slave
controller for dual comfort. It offers easier operation
and backlit display.
1. Fresh air output port. External fresh air fans can be
connected to run in conjunction with the fan motor of
the indoor unit.
2. Electrical heater output port. An External Electrical
heater can be set to operate in conjunction with the
heating cycle.
3. External input port. Start/stop of the air conditioner
can be controlled from external equipment.
Advanced features (UTD-ECS5A Required)
Hydrophillic coatingCobalt Blue protectionStandard cromate protectionAluminium base material
Detecting point can be changed easily
DAY NIGHT
Remote Sensor Opt
Wired Remote Controller
6
Room temperature sensor selection
• Remote controller has remote
sensor included.
• User can select between remote
controller sensor and/or
return air sensor or
remote sensor.
Remote Sensor in the bedroom
(effective at night)
Remote Controller in the living room
(effective during the day)
Example of ducted system configuration
Easy installation (compact size & light weight).
Size & weight have been reduced making installation considerably easier.
Operation sound (low noise)
The new ducted models have increased airflow volume
& decreased noise levels to 49dBA by adopting a
plastic case, plastic fan and three airflow volume
switch positions.
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 7
7
INVERTER Ducted
ART30L
8.80kW / 30,000BTU/h
9.20kW / 31,400BTU/h
C
H
ART36L
10.00kW / 34,100BTU/h
10.00kW / 34,100BTU/h
C
H
ART45L
12.50kW / 42,700BTU/h
14.00kW / 47,800BTU/h
C
H
ART54L
14.50kW / 49,500BTU/h
16.00kW / 54,600BTU/h
C
H
ARY36L*
10.00kW / 34,100BTU/h
11.20kW / 38,250BTU/h
C
H
Wired type (with weekly/setback timer) For ARY36L
Wired type (with weekly/setback timer)
For ART45L/54L
For ART30L/36L
* Project order only. Minimum Delivery time 16 weeks
Control Features
Turbulent air flow is reduced by cutting off the corners of the conventional
indoor unit front panel and fan case. Uniform internal air pressure
decreases the noise level down to 41dBA (ART45L) and 42dBA (ART54L).
• Large air flow volume of 972 Litres/second (ART45/54L) is achieved
by adopting a larger fan. (Figures given at 100Pa).
• Low noise is achieved by use of a plastic case, plastic fan and
3-step airflow volume switch.
• Sirocco fan for airflow and indoor unit fan casing are also made
from plastic.
Operation sound (Low noise)
Current model NEW MODEL
Current model : Metal fan [53.1dB(A)]
* Model : Material (At 100Pa : Actual noise measurement value)
NEW MODEL : Plastic fan [41dB(A)]
800mm
Metal fan (ø240mm)
Casing (Metal Sheet)
40
0m
m
Heat exchangerPlastic fan
Casing (Plastic)
500mm
40
0m
m
ø225mmHeat exchanger
1 2 3
Various remote controllers and sensors can be
selected.
1. Wired Remote Controller with Thermo Sensor
• Room temperature sensor selection
• WEEKLY timer
• Temperature SET BACK timer
• Group control system
• Child lock
• Dual remote controllers (optional parts)
• AUTO restart
• Energy saving
• Auto changeover (for heating)
• Hot start (for heating)
2. Simple Remote Controller (optional parts)
3. Remote Sensor (optional parts)
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 8
8
INVERTER Cassette
INVERTER Large Under Ceiling
Wired type (with weekly/setback timer) For AUT30L/36L For AUT45L/54L
AUT36L
10.0kW / 34,100BTU/h
11.2kW / 38,200BTU/h
C
H
AUT30L
8.5kW / 29,000BTU/h
10.0kW / 34,100BTU/h
C
H
AUT45L
12.5kW / 42,700BTU/h
14.0kW / 47,800BTU/h
C
H
AUT54L
14.0kW / 47,800BTU/h
16.0kW / 54,600BTU/h
C
H
ABT30L*
TBA
TBA
C
H
Control Features (AUT30/36/45/54L)
Duct connection hole opening
Easy maintenance (AUT30/36/45/54L)
Long-life filter
Various remote controllers and sensors can
be selected.
Wired Remote Controller with Thermo Sensor
• Room temperature sensor selection
• Temperature SET BACK timer
• Group control system
• Child lock
• Dual remote controllers (optional)
• Hot start (for heating)
The control box is easily accessible for maintenance work.
Wide opening for easy access. Detachable, washable filter
and intake grille. Wide opening and long-life filter.
High efficiency, long-life filter extends the cleaning cycle.Long life filter
Conditioned air can be distributed by means
of a distribution duct.
Distribution duct
Distribution duct
Fresh air
Fresh air can be introduced through this opening.
Fresh air can be introduced
through thisopening
Distribution duct Fresh air
Distributionduct
Two-way
Two-wayAUT30/36/45/54L
One-way
One-wayAUT30/36/45/54L
Condensate pump
For ABT30/36L For ABT45L
Ultra thin and wide air flow design for elegance and comfort.
Low noise realised
The outdoor unit’s fan shape (large
metal plate integrated bell mouth)
reduces the air flow resistance and
lowers noise levels (external fan
guard) so units are less obtrusive
to neighbours.
Improved installation/maintenance
Check joint standard equipment
Service port is provided at the high pressure side of the
refrigerant circuit. The operation of the air conditioning
refrigeration system can be checked by connecting a pressure
gauge, etc. and installation and maintenance work is improved.
Improved handling during installation
The new outdoor unit is equipped with handles at the front
and back at about the same height as the left and right so
that the unit can be easily carried during installation, etc.
* Due late 2007. Check with yourFujitsu dealer for availability.
Condensate pump lift to 800mm(AUT30/36/45/54L)
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 9
Wall Mountedtype (Small Size)
Wall Mountedtype (Large Size)
Cassette type(Compact)
Floor/CeilingUniversal type
Duct type(Small size)
Duct type
AST7LM
AST9LM
AST12LM
AST18LB
AST24LB
AUT18LB
ABT24LB
ABT18LB
ABT14LBAUT14LB
AUT12LB
ART9L
AO
T3
0L
M4
AO
T2
4L
M2
AOT30LM4
AOT24LM21 outdoor unit to 2 indoor unitsThe total capacity of the indoor units that can be connected is 4.4 - 8.7kW(15,000 - 30,000BTU)
1 outdoor unit to 3–4 indoor unitsThe total capacity of the indoor units that can be connected is 7.9 - 14.3kW(27,000 - 49,000BTU)
2.3kW
2.7kW
3.5kW
4.2kW
5.2kW
6.3kW
6.8kW
(7,900BTU)
(9,200BTU)
(11,900BTU)
(14,300BTU)
(17,800BTU)
(21,500BTU)
(23,200BTU)
ART12L
ART14L
ART18L
ART22L
9
INVERTER Multi System
Wired type
ABT14/18/24LB
Universal Type
AUT12/14/18LB
Cassette Compact Type ART12/14/18/22L Duct TypeART9L Duct Type (small)
AST7/9/12LM
Wall Mounted Type
AST18/24LB
Wall Mounted Type
Wired type
AOT24LMAM2
5.8kW / 19,800BTU/h
6.4kW / 21,900BTU/h
C
H
AOT30LMAW4
8.00kW / 27,300BTU/h
9.60kW / 32,800BTU/h
C
H
New Model
AUT12L/14L/18LART9L/12L/14L/18L/22LABT14L/18L/24LAST7L/9L/12L/18L/24L
For AST18/24L only
The New Fujitsu Inverter Multi System is ideal where an
individual indoor unit is required in each room, i.e., a living
room and 3 bedrooms. The Multi Systems allows one
outdoor unit to be connected up to a wide variety of
3 or 4 indoor units including Wall Mounted, Floor/Ceiling
Console, Cassette and Ducted.
Refer to dealer for selection chart.
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 10
10
CONVENTIONAL Ducted
Installation styles
(ART25/30/ARY45)
Low static pressure mode function (ART25/30 ARY45)
Slim & compact design
Optional functionfor comfort andoptional parts
(ART25/30/ARY45)
Year round comfort. A Fujitsu ducted system
provides air conditioned comfort to new and existing
homes. This means you can enjoy climate controlled
comfort all year round, all round the house.
ART25U
7.10kW / 24,100BTU/h
7.70kW / 26,300BTU/h
C
H
ART30U
8.50kW / 29,400BTU/h
9.50kW / 32,400BTU/h
C
H
ARY45U
12.70kW / 43,400BTU/h
14.30kW / 48,800BTU/h
C
H
Wired type (with weekly/setback timer) For ART25U For ART30U For ARY45U
Return air connection can be on the bottom
or rear of the indoor unit (Bottom connection
illustrated). Also, in addition to the already
slim height of the indoor unit at 270mm,
further size reduction is attained by reducing
65mm from the width with the flanking
control box imbedded inside the chassis.
1,200 1,135mm
270mm
Cm
The convexshaped controlbox is nowintegrated withinthe indoor unit(DIP Switch islocated on theinternalsubstrate.)
Static pressure (Pa)
1 2
0 70 100
Air
vo
lum
e(m
3/h
)
1. Low static pressure mode 1 air volume at 70Pa
(fan speed: high)
2. Normal Mode Air volume at 100Pa (fan speed:high)
When installed, normal middle static pressure mode and
low static pressure mode can be selected by switching
over using the DIP switch on the board in the control
box. Therefore, these models can be operated under a
wide range of conditions.
Other features
• Air intake position is selectable.
(Rear or Bottom)
• Air outlet shape is selectable at the
time of purchase. (Round or Square)
• Drain pipe position is selectable.
(Right or Left)
• Fresh air can be taken in.
Concealed ducted airconditioning system
• Perfect comfort throughout
each room.
• Visually appealing
• Concealed installation
• Reverse cycle heating & cooling
• Quiet operation
• Easy-to-use LCD remote controller
• Remote sensor (ART25/30/ARY45)
Optional partsRemote sensor unit UTD-RS100
Simple remote controller UTB-TPB
Flange (square) UTD-SF045T
Flange (round) UTD-RF204
Simple remote controllers (UTB-TPB)
1. Control box
2. Fan casing
3. Fan
4. Motor
Conventional model
2
4
1
3
Large bottom panel: 1 unit
New model
1
4
32
Bottom panel: 2 units
Conventional model
R SRemote sensor unit
(UTD-RS100)
Embedded
in ceiling
Hanging
in ceiling
One-touch operating and easy-to-install long-lifefilter (Optional Parts) – European model only.
Receiver unit &
Wireless Remote
Controller
New model
Easy maintenance
In the case of rear return air connection as illustrated below, structural improvement is
attained by making the bottom panel two pieces, front and rear. The internal fan casing
is also made dismountable in two pieces, namely, upper and lower sections. Motor and fan
maintenance and dismounting can be easily performed by removing the rear panel and
lower part of the casing with the main chassis installed.
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 11
11
Remote Sensor in the bed room (effective at night)
Remote Cin the livin(effective
Remote Sensor in the bedroom(effective at night)
Remote Controller in the living room (effective during the day)
Wired type (with weekly/Setback timer)
ART36U
10.5kW / 36,000BTU/h
12.0kW / 40,980BTU/h
ART45U
12.7kW / 43,500BTU/h
14.3kW / 48,800BTU/h
ART60U
16.50kW / 56,300BTU/h
19.70kW / 67,200BTU/h
C
H
C
H
C
H
C
HWired type
(with weekly/Setback timer)
Accurate and Comfortable
• Comfortable room temperature control is available by
utilising the thermo sensor in the remote controller.
• Because the remote controller has a switching
function, the user can select which sensor is used.
(Room temperature sensor selection)
Example of roomtemperature sensorselection
Wired Remote Controller Remote Sensor (Optional Parts)The detecting point can be freely changed.
Day NightTHERMOSENSOR
Wired Remote Controller The detecting point can be freely changed. Remote Sensor (Optional Parts)
Sensor part
ART90T
26.40kW / 87,000BTU/h
29.50kW / 100,000BTU/h
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 12
12
Simple maintenence
Control switches are
installed in the grille
for easy maintenance.
Detachable andwashable airintake grille
Wide opening.
Slender setting
250or
more
Standard setting
285or
more
Weekly timer
The sophisticated weekly timer and remote controller not
only makes it easy to adjust air conditioning units, but can
also help achieve considerable savings. It allows the air
conditioning system to be programmed in advance to
operate only as and when required.
The function of weekly timer
• Set different on/off times for each day of the week.
• Set two different on/off times for each day.
• Set time by 5 minute intervals.
• The timer operation of a reserved day can temporarily
be cancelled by pushing the “DAY OFF” button.
• If day function is used, weekly timer will resume next day.
• System can be manually over-riden.
Slender fit (2-way setting)
This new mechanism enables the cassette body to move 35mm
downward and allows installation into a 250mm space.
No special work or options are needed.
Elegant design
This ultra-thin air conditioner can
be installed in any narrow ceiling.
The fascia’s elegant design leaves the
air conditioner flush with the ceiling.
285 or
250
940
94
0
83
0
830
4-STEP SWING 4-STEP SWING
Refer tospecifications.Indoor unit holecut out size.
Swing louvres
The airflow direction, up or down is set automatically to match
the operating mode, i.e. down for heating, up for cooling.
4-Way air flow system
Slim size
The small and compact
body allows space
saving installation.
830mm
28
5m
m
30mm
2-way 3-way 4-way
CONVENTIONAL Cassette AUT36U
10.50kW / 35,800BTU/h
12.00kW / 40,900BTU/h
C
H
AUT45U
12.70kW / 43,400BTU/h
14.30kW / 48,800BTU/h
C
H
AUT54U
14.50kW / 49,500BTU/h
16.50kW / 56,300BTU/h
C
H
For AUT36U/45U
Wired type (with weekly/Setback timer)
For AUT54U
Efficient, simple, discreet. Incorporating the latest
fan technology, these units fit neatly into the ceiling
and distribute conditioned air through 2, 3 or 4 sides
of the unit. In addition, louvres allow air to be directed
in either a pre-set or sweep pattern.
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 13
13
Large Under Ceiling
Quiet & Elegant. This lightweight, slim airconditioner fits directly under the ceiling. It is extremely quiet, yet extremely powerful. Because of their design, ceiling suspendedunits can be installed quickly, simply andwith minimum disruption.
CONVENTIONAL
ABT36U
10.50kW / 35,800BTU/h
12.00kW / 40,900BTU/h
C
H
ABT45U
12.70kW / 43,400BTU/h
14.30kW / 48,800BTU/h
C
H
ABT54U
14.50kW / 49,500BTU/h
16.50kW / 56,300BTU/h
C
H For ABT36U For ABT45U/54U
Fresh-air intake
Condensate water pump
The optional condensate water pump offers
more flexible installation by lifting the drain
and discharge point by 400mm.*
(optional)
*Refer to installation instructions.
OUTDOORINDOOR
Fresh Air
SWING
Double auto swing
Right and left
Control over air direction swing is possible through dual use of both an
up/down air direction swing and right/left air direction swing. Since up/down
air direction louvres operate automatically according to the operating mode
of the unit, it is possible to set air direction based on the operation mode.
SWING
Low noise realised
The outdoor unit’s fan shape (large metal
plate integrated bell mouth) reduces the
air flow resistance and lowers noise levels
(external fan guard) so units are less
obtrusive with neighbours.
WIDE AIR FLOW
Improved installation/maintenance
Check joint standard equipment
Service port is provided at the high pressure side
of the refrigerant circuit. The operation of the air
conditioning refrigeration system can be checked
by connecting a pressure gauge, etc. and
installation and maintenance work is improved.
Improved handling during installation
The new outdoor unit is equipped with handles at the front and back at about
the same height as the left and right so that the unit can be easily carried.
Features of new outdoor unit
(ABT36/45/54)
Up and down
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 14
The Fujitsu Airstage VRF J Series is a breakthrough in compact VRF systems.
Ideal for larger domestic or smaller commercial applications, this system
offers many of the features found in Fujitsu’s renowned high-end
VRF systems, including quiet, efficient operation and Inverter Technology.
Our J series can also support up to 8 indoor units for every outdoor
unit, including ducted and ultra-thin ducted, cassette and slim-cassette,
and wall mounted split systems.
So talk to one of Fujitsu’s qualified Sales Engineers about your next
project. No matter what the building, we’ve got the solution.
If it can be designed, we can air condition it.
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 15
When it comes to air conditioning
large buildings, Fujitsu General has the
solution. The new generation Airstage
V-Series. This high performance multi
air conditioning VRF solution is
designed to service a variety of
commercial applications and offers
many improvements on earlier systems.
To make installation easier, the Airstage
V-Series will allow pipe runs up to 150m
between indoor and outdoor units
and pipes of up to 60m long to be
connected between the first separation
tube and the furthest indoor unit.
Improvements to the compressor
operation and the introduction of a
primary inverter compressor mean the
V-Series is better equipped to maintain
a constant and comfortable indoor
environment. New compressor rotation
also equalizes the load on each
compressor to make the system more
durable and reliable. A three-way oil
control system further optimises
compressor efficiency.
For improved comfort, high precision
control technology allows the Airstage
V-Series to maintain the set room
temperature to within 0.5 degrees
Celsius.
The system offers design freedom by
allowing three outdoor units to be
connected together in series, and up
to 48 indoor units to be run on one
refrigerant piping system.
With a wide choice of indoor unit types,
the Airstage V-Series can be installed
in both new and existing buildings.
ir condition it.
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 16
16
Type INVERTER
Model No.Indoor Unit ART30LUAK ART36LUAK ART45LUAK ART54LUAK ARY36LUANOutdoor Unit AOT30LMBDL AOT36LMADL AOT45LJBYL AOT54LJBYL AOY36LMBWL
Reverse Cycle System Yes Yes Yes Yes YesOptional Simple Wired RC UTB-TPB UTB-TPB UTB-TPB UTB-TPB UTB-TPBOptional Remote Sensor UTD-RS100 UTD-RS100 UTD-RS100 UTD-RS100 UTD-RS100
Cooling CapacityWatts 8800 10000 12500 14500 10000BTU/h 30000 34100 42700 49500 34100
RangeWatts 2700-9800 2700-10500 3600-14000 6400-15300 Max 11200BTU/h 9200-33500 9200-36000 12300-47800 21900-52200 Max 38200
Heating CapacityWatts 9200 10000 14000 16000 11200
BTU/h 31400 34100 47800 54600 38250
RangeWatts 3000-11000 3000-12100 4700-18000 6800-20000 Max 12770BTU/h 10200-37600 10200-41300 47800-61500 23200-68300 Max 43600
Power Supply Volts 240 240 240 240 240Phase-Frequency Ph- Hz 1-50 1-50 1-50 1-50 1-50Power Supply Attachment Outdoor Outdoor Outdoor Outdoor Outdoor
Running Current Cooling Amps 13.8 (4.6-17.3) 16.7(4.6-17.6) 18.1(7.1-21.7) 23.5 (7.1-25.3) 17.9 (Max 18.4)Heating Amps 10.7 (4.3-17.3) 11.7 (4.3-17.6) 16.0 (6.3-20.1) 19.8 (6.3-25.3) 13.9 (Max 18.4)
InputCooling Watts 3300 (1080-4150) 4000 (1080-4200) 4300 (1700-5200) 5570 (1700-6060) 4080 (Max 4200)Heating Watts 2550 (1000-4150) 2800 (1000-4200) 3800 (1500-4800) 4700 (1500-6060) 3180 (Max 4150)
Moisture Removal l/hr 3 3 3 4 3E.E.R. Cooling 2.67 2.5 2.91 2.6 2.45C.O.P. Heating 3.61 3.57 3.68 3.40 3.52
Star RatingCooling ★★★ ★★★■ ★★★★ ★★★ -Heating ★★★★★ ★★★★★ ★★★★★★■ ★★★★★■ -
Fan Speeds 3 3 3 3 3Ex Static Pressure Range Pa 100 to 200 100 to 200 100 to 250 100 to 250 30 to 150Air Circulation High l/s 694@100Pa 694@100Pa 972@100Pa 972@100Pa 486Compressor Type DC Twin Rotary DC Twin Rotary DC Scroll DC Scroll DC Twin Rotary
Height mm 400 400 400 400 270I.U. Width mm 1050 1050 1050 1050 1135
Depth mm 500 500 500 500 700Dimensions Net Weight kg 45 45 50 50 43and Weights Height mm 900 900 1290 1290 830
O.U. Width mm 900 900 900 900 900Depth mm 350 350 330 330 330Net Weight kg 70 70 105 105 64
Duct Work Plenum SizeSupply mm 850 x 295 850 x 295 850 x 295 850 x 295 1065 x 202Return mm 865 x 325 865 x 325 865 x 325 865 x 325 1015 x 240
Optional Supply SpigotsSquare Qty 1 - - - - UTD-SFO45TRound Qty 4 - - - - UTD-RF204
I.U. Sound Pressure Level dBA@1mtr 45 45 49 49 43O.U. Sound Pressure Level dBA@1mtr 53 53 54 54 54O.U. Sound Power Level dBA 65 65 65 69 66Refrigerant Type R410A R410A R410A R410A R410A
Connection Pipe SizesGas mm 15.88 15.88 15.88 15.88 15.88Liquid mm 9.52 9.52 9.52 9.52 9.52
Refrigerant Pre Charged Length Metre 10 10 20 20 15Minimum Pipe Length Metre 5 5 5 5 5Maximum Pipe Length Metre 30 30 70 70 50Maximum Pipe Height Metre 20 20 30 30 30Pipe Connection Methods Flare Flare Flare Flare Flare
Outdoor Operating Temp.Cooling Degrees C 0 to 43 0 to 43 -15 to 43 -15 to 43 -10 to 43Heating Degrees C -10 to 21 -10 to 21 -15 to 24 -15 to 24 -10 to 24
DUCTEDINVERTER
Type WALL MOUNTED FLOOR/CEILING CASSETTE
Model No.Indoor Unit AST7LMACW AST9LMACW AST12LMACW AST18LBAJ AST24LBAJ ABT14LBAJ ABT18LBAJ ABT24LBAJ AUT12LBAB AUT14LBAB AUT18LBABOutdoor Unit - - - - - - - - - - -
Reverse Cycle System Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Cooling CapacityWatts 2300 2700 3500 5200 6800 4200 5200 6800 3500 4000 4300
BTU/h 7900 9200 11900 17800 23200 14300 17800 23200 11900 13700 14700
Maximum Watts 2700 3400 3700 6000 7400 5000 6000 7400 3800 4500 5200
BTU/h 9200 11600 12600 20500 25300 17200 20500 25300 13000 15400 17800
Heating CapacityWatts 2700 3300 3800 6000 8200 4800 6000 8200 3800 4300 5000
BTU/h 9200 11300 13000 20500 28000 16400 20500 28000 13000 14700 17100
Maximum Watts 3300 3700 4500 7100 9000 5700 7100 9000 4500 5200 6300
BTU/h 11300 12600 15400 24200 30700 19500 24200 30700 15400 17800 21150Power Supply Volts 240 240 240 240 240 240 240 240 240 240 240Phase-Frequency Ph- Hz 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50Power Supply Attachment Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor OutdoorPlug Size (If Applicable) - - - - - - - - - - -
Cooling Amps - - - - - - - - - - -
Running Current Range Amps - - - - - - - - - - -Heating Amps - - - - - - - - - - -Range Amps - - - - - - - - - - -Cooling Watts - - - - - - - - - - -
InputRange Watts - - - - - - - - - -Heating Watts - - - - - - - - - - -Range Watts - - - - - - - - - - -
Moisture Removal l/hr 1 1.2 1.6 3 3 1.5 1.7 2.5 1.3 1.5 2E.E.R. Cooling - - - - - - - - - - -C.O.P. Heating - - - - - - - - - - -
Star RatingCooling - - - - - - - - - - -Heating - - - - - - - - - -
Fan Speeds 4 4 4 4 4 3 3 3 3 3 3Air Circulation High l/s 119 130 144 263 283 177 216 244 152 152 172Compressor Type - - - - - - - - - - -
Height mm 257 257 257 320 320 199 199 199 235 235 235
I.U.Width mm 808 808 808 1120 1120 990 990 990 580 580 580Depth mm 187 187 187 220 220 655 655 655 580 580 580
Dimensions Net Weight kg 8 8 8 16 16 28 28 28 18 18 18and Weights Height mm - - - - - - - - - - -
O.U. Width mm - - - - - - - - - - -Depth mm - - - - - - - - - - -Net Weight kg - - - - - - - - - - -
I.U. Sound Pressure Level dBA@1mtr 34 36 38 43 47 36 43 48 42 42 44O.U. Sound Pressure Level dBA@1mtr - - - - - - - - - - -O.U. Sound Power Level dBA - - - - - - - - - - -Refrigerant Type R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
Connection Pipe SizesGas mm 9.52 9.52 9.52 12.7 15.88 12.7 12.7 15.88 9.52 12.7 12.7Liquid mm 6.35 6.35 6.35 6.35 9.52 6.35 6.35 9.52 6.35 6.35 6.35
Pre Charged Length Metre - - - - - - - - - - -Minimum Pipe Length (per unit) Metre - - - - - - - - - - -Maximum Pipe Length (per unit) Metre - - - - - - - - - - -Maximum Pipe Length Metre 25 25 25 25 25 25 25 25 25 25 25Maximum Pipe Height Metre 10 10 10 10 10 10 10 10 10 10 10Pipe Connection Methods Flare Flare Flare Flare Flare Flare Flare Flare Flare Flare Flare
Outdoor Operating Temp.Cooling Degrees C - - - - - - - - - - -Heating Degrees C - - - - - - - - - - -
MULTI SYSTEM INVERTERINVERTER
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 17
17
Type OUTDOOR
Model No.Indoor Unit - -Outdoor Unit AOT30LMAW4 AOT24LMAM2
Reverse Cycle System Yes Yes
Cooling CapacityWatts 8000 5800
BTU/h 27300 19800
Maximum CapacityWatts 10100 7800
BTU/h 34500 26600
Heating CapacityWatts 9600 6400
BTU/h 32800 21900
Maximum CapacityWatts 12000 9000
BTU/h 41000 30700Power Supply Volts 240 240Phase-Frequency Ph- Hz 1-50 1-50Power Supply Attachment Outdoor OutdoorPlug Size (If Applicable) N/A N/A
Running Current Cooling Amps 9.3 7.3
Max 15.7 Max 12.2Heating Amps 10.1 6.9
Max 15.7 Max 12.2
InputCooling Watts 2220 1730
Max 3580 Max 2920Heating Watts 2400 1640
Moisture Removal l/hr Max 3580 Max 2920- -
E.E.R. Cooling 3.6 3.35C.O.P. Heating 4 3.9
Star RatingCooling - -Heating - -
Fan Speeds - -Air Circulation High l/s 972 805Compressor Type Twin Rotary Twin Rotary
Height mm - -
I.U. Width mm - -Depth mm - -
Dimensions Net Weight kg - -and Weights Height mm 835 650
O.U. Width mm 900 830Depth mm 330 320Net Weight kg 68 56
I.U. Sound Pressure Level dBA@1mtr - -O.U. Sound Pressure Level dBA@1mtr 51 49O.U. Sound Power Level dBA 64 62Refrigerant Type R410A R410A
Connection Pipe SizesGas mm 2 x 9.52, 2 x 12.7 1 x 12.7, 1 x 9.52Liquid mm 4 x 6.35 2 x 6.35
Pre Charged Length 50 30Minimum Pipe Length (per unit) Metre 5 5Maximum Pipe Length (per unit) Metre 25 20Maximum Pipe Length Metre Max Total 70 Max Total 30Maximum Pipe Height Metre 10 10Pipe Connection Methods Flare Flare
Outdoor operating Temp.Cooling Degrees C 0 to 43 0 to 43Heating Degrees C -10 to 24 -10 to 24
Type BULKHEAD
Model No.Indoor Unit ART9LUAB ART12LUAD ART14LUAD ART18LUAD ART22LUADOutdoor Unit - - - - -
Reverse Cycle System Yes Yes Yes Yes Yes
Cooling CapacityWatts 2700 3500 4200 5200 6300
BTU/h 9200 11900 14300 17800 21500
Maximum CapacityWatts 3300 4000 5000 6000 6800
BTU/h 11300 13600 17100 20500 23200
Heating CapacityWatts 3300 3800 4800 6000 7500
BTU/h 11300 13000 16400 20500 25600
Maximum CapacityWatts 3600 4500 5800 7100 8800
BTU/h 12300 15400 19800 24200 30000Power Supply Volts 240 240 240 240 240Phase-Frequency Ph- Hz 1-50 1-50 1-50 1-50 1-50Power Supply Attachment Outdoor Outdoor Outdoor Outdoor OutdoorPlug Size (If Applicable) - - - - -
Running Current Cooling Amps - - - - -Heating Amps - - - - -
InputCooling Watts - - - - -Heating Watts - - - - -
- - - - -- - - - -- - - - -- - - - -
Moisture Removal l/hr 1 1.2 1.5 1.7 2.5E.E.R. Cooling - - - - -C.O.P. Heating - - - - -
Star RatingCooling - - - - -Heating - - - - -
Fan Speeds 3 3 3 3 3Air Circulation High l/s 125 161 216 222 288Compressor Type - - - - -
Height mm 217 217 217 217 217I.U. Width mm 663 953 953 953 953
Depth mm 595 595 595 595 595Dimensions Net Weight kg 18 25 25 25 25and Weights Height mm - - - - -
O.U. Width mm - - - - -Depth mm - - - - -Net Weight kg - - - - -
I.U. Sound Pressure Level dBA@1mtr 39 33 40 41 46O.U. Sound Pressure Level dBA@1mtr - - - - -O.U. Sound Power Level dBA - - - - -Refrigerant Type R410A R410A R410A R410A R410A
Connection Pipe SizesGas mm 9.52 9.52 12.7 12.7 12.7Liquid mm 6.35 6.35 6.35 6.35 6.35
Pre Charged Length - - - - -Minimum Pipe Length (per unit) Metre - - - - -Maximum Pipe Length (per unit) Metre - - - - -Maximum Pipe Length Metre 25 25 25 25 25Maximum Pipe Height Metre 10 10 10 10 10Pipe Connection Methods Flare Flare Flare Flare Flare
Outdoor operating Temp.Cooling Degrees C - - - - -Heating Degrees C - - - - -
CASSETTET24LBAJ AUT12LBAB AUT14LBAB AUT18LBAB
- - - -Yes Yes Yes Yes
6800 3500 4000 43003200 11900 13700 147007400 3800 4500 52005300 13000 15400 17800
8200 3800 4300 50008000 13000 14700 17100
9000 4500 5200 63000700 15400 17800 21150240 240 240 2401-50 1-50 1-50 1-50utdoor Outdoor Outdoor Outdoor
- - - -- - - -- - - -- - - -- - - -- - - -- - -- - - -- - - -
2.5 1.3 1.5 2- - - -- - - -- - - -- - -3 3 3 3
244 152 152 172- - - -
199 235 235 235990 580 580 580655 580 580 58028 18 18 18- - - -- - - -- - - -- - - -
48 42 42 44- - - -- - - -
R410A R410A R410A R410A5.88 9.52 12.7 12.79.52 6.35 6.35 6.35
- - - -- - - -- - - -
25 25 25 2510 10 10 10
Flare Flare Flare Flare- - - -- - - -
Type INVERTER
Model No.Indoor Unit ABT30LBAG ABT36LBAG ABT45LBAGOutdoor Unit TBA TBA TBA
Reverse Cycle System Yes Yes Yes
Cooling CapacityWatts TBA TBA TBABTU/h TBA TBA TBA
Heating CapacityWatts TBA TBA TBA
BTU/h TBA TBA TBAPower Supply Volts TBA TBA TBAPhase-Frequency Ph- Hz TBA TBA TBAPower Supply Attachment TBA TBA TBA
Running CurrentCooling Amps TBA TBA TBAHeating Amps TBA TBA TBA
InputCooling Watts TBA TBA TBAHeating Watts Outdoor Outdoor Outdoor
Moisture Removal l/hr TBA TBA TBAE.E.R. Cooling TBA TBA TBAC.O.P. Heating TBA TBA TBA
Star RatingCooling TBA TBA TBAHeating TBA TBA TBA
Fan Speeds TBA TBA TBAAir Circulation High l/s TBA TBA TBACompressor Type TBA TBA TBA
Height mm TBA TBA TBAI.U. Width mm TBA TBA TBA
Depth 830 TBA TBA TBADimensions Net Weight kg TBA TBA TBAand Weights Height mm TBA TBA TBA
O.U. Width mm TBA TBA TBADepth mm TBA TBA TBANet Weight kg TBA TBA TBA
I.U. Sound Pressure Level dBA@1mtr TBA TBA TBAO.U. Sound Pressure Level dBA@1mtr TBA TBA TBAO.U. Sound Power Level dBA TBA TBA TBARefrigerant Type TBA TBA TBA
TBA TBA TBA
Connection Pipe SizesGas mm TBA TBA TBALiquid mm TBA TBA TBA
Pre Charged Length TBA TBA TBAMinimum Pipe Length Metre R410A R410A R410AMaximum Pipe Length Metre TBA TBA TBAMaximum Pipe Height Metre TBA TBA TBAPipe Connection Methods TBA TBA TBA
Outdoor operating Temp.Cooling Degrees C TBA TBA TBAHeating Degrees C TBA TBA TBA
TBA TBA TBA TBA TBA TBA TBAFlare Flare FlareTBA TBA TBATBA TBA TBA
LARGE UNDER CEILINGType INVERTER
Model No.Indoor Unit AUT30LUAS AUT36LUAS AUT45LUAS AUT54LUASOutdoor Unit AOT30LNAWL AOT36LNAWL AOT45LJBYL AOT54LJBYL
Reverse Cycle System Yes Yes Yes Yes
Cooling CapacityWatts 8500 10000 12500 14000BTU/h 29000 34100 42700 47800
RangeWatts 3000-10000 5000-11200 3000-14000 6400-14500BTU/h 10200-34100 17000-38200 10200-47800 21800-49500
Heating CapacityWatts 10000 11200 14000 16000
BTU/h 34100 38200 47800 54600
RangeWatts 3000-11200 5150-12770 3000-16000 6800-16500BTU/h 10200-38200 17600-43300 10200-54600 23200-56300
Power Supply Volts 240 240 240 240Phase-Frequency Ph- Hz 1-50 1-50 1-50 1-50Power Supply Attachment Outdoor Outdoor Outdoor Outdoor
Running CurrentCooling Amps 12 (4.6-14.6) 16.8 (4.6-17.5) 18.6 (7.1-22.6) 23.5 (7.1-24.0)
Heating Amps 11.9 (4.3-14.6) 14.6 (4.3-17.5) 16.6 (6.3-20.0) 20.4 (6.3-21.8)
InputCooling Watts 2860 (1080-3500) 4010 (1080-4200) 4450 (1700-5150) 5600 (1700-5700)
Heating Watts 2840 (1000-3500) 3490 (1000-4200) 3950 (1500-4600) 4850 (1500-5200)
Moisture Removal l/hr 3 4 4.5 5.5E.E.R. Cooling 2.97 2.49 2.81 2.50 C.O.P. Heating 3.52 3.21 3.54 3.30
Star RatingCooling ★★★★ ★★★■ ★★★★■ ★★★■Heating ★★★★★ ★★★★ ★★★★★ ★★★★
Fan Speeds 3 3 3 3Air Circulation High l/s 444 444 486 486Compressor Type DC Twin Rotary DC Twin Rotary DC Scroll DC Scroll
Height mm 296 296 296 296I.U. Width mm 830 830 830 830
Depth mm 830 830 830 830Dimensions Net Weight kg 37 37 40 40and Weights Height mm 830 830 1290 1290
O.U. Width mm 900 900 900 900Depth mm 330 330 330 330Net Weight kg 64 64 105 105
Ceiling Opening Measurement mm 890 x 890 890 x 890 890 x 890 890 x 890I.U. Sound Pressure Level dBA@1mtr 48 48 51 51O.U. Sound Pressure Level dBA@1mtr 53 54 54 54O.U. Sound Power Level dBA 65 65 66 66Refrigerant Type R410A R410A R410A R410A
Connection Pipe SizesGas mm 15.88 15.88 15.88 15.88Liquid mm 9.52 9.52 9.52 9.52
Pre Charged Length Metre 15 15 20 20Minimum Pipe Length Metre 5 5 5 5Maximum Pipe Length Metre 50 50 70 70Maximum Pipe Height Metre 30 30 30 30Pipe Connection Methods Flare Flare Flare Flare
Outdoor Operating Temp.Cooling Degrees C -10 to 43 -10 to 43 -15 to 43 -15 to 43Heating Degrees C -10 to 24 -10 to 24 -15 to 24 -15 to 24
CASSETTEINVERTER
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 18
Type CONVENTIONAL
Model No.Indoor Unit ART36UUAK ART45UUAK ART60UUAK ART90TUAJOutdoor Unit AOT36UNAXT AOT45UMAXT AOT60UMAYT AOT90TPC3L
Reverse Cycle System Yes Yes Yes YesOptional Simple Wired RC UTB-TPB UTB-TPB UTB-TPB UTB-TPBOptional Remote Sensor UTD-RS100 UTD-RS100 UTD-RS100 UTD-RS100
Cooling CapacityWatts 10500 12700 16500 26400
BTU/h 36000 43500 56300 87000
Heating CapacityWatts 12000 14300 19700 29500
BTU/h 40980 48800 67200 100000Power Supply Volts 415 415 415 415Phase-Frequency Ph- Hz 3-50 3-50 3-50 3-50Power Supply Attachment Outdoor Outdoor Outdoor Indoor & Outdoor
Running CurrentCooling Amps 6.2 7.8 10.9 19.5Heating Amps 6.2 7.7 10.6 19.5
InputCooling Watts 3750 4550 6200 10100Heating Watts 3450 4200 5750 10100
Moisture Removal l/hr 2 3 4 7.5E.E.R. Cooling 2.80 2.79 2.66 2.61 C.O.P. Heating 3.48 3.40 3.43 2.92
Star RatingCooling - - - -Heating - - - -
Fan Speeds 3 3 3 1Ex Static Pressue Range Pa 100 to 200 100 to 200 100 to 250 100 to 300Air Circulation High l/s 720@100Pa 750@100Pa 1000@100Pa 1200@200PaCompressor Type Twin Rotary Scroll Scroll Scroll
Height mm 400 400 400 450
I.U.Width mm 1050 1050 1050 1550Depth mm 500 500 500 700
Dimensions Net Weight kg 50 50 50 85and Weights Height mm 1165 1165 1290 1380
O.U. Width mm 900 900 900 1300Depth mm 330 330 330 650Net Weight kg 94 113 118 245
Ductwork Plenum SizeSupply mm 850 x 295 850 x 295 850 x 295 1200 x 350Return mm 865 x 325 865 x 325 865 x 325 1250 x 370
Optional Supply SpigotsSquare Qty 1 - - - -Round Qty 4 - - - -
I.U. Sound Pressure Level dBA@1mtr 44 45 49 50O.U. Sound Pressure Level dBA@1mtr 55 55 55 59O.U. Sound Power Level dBA 68 68 68 70Refrigerant Type R410A R410A R410A R407C
Connection Pipe SizesGas mm 15.88 19.05 19.05 28.58Liquid mm 9.52 9.52 9.52 12.7
Pre Charged Length 20 20 20 30Minimum Pipe Length 5 5 5 5Maximum Pipe Length Metre 50 50 50 50Maximum Pipe Height Metre 30 30 30 30Pipe Connection Methods Flare Flare Flare Flare & Flange
Outdoor operating Temp.Cooling Degrees C 0 to 43 0 to 43 0 to 43 0 to 46Heating Degrees C -10 to 24 -10 to 24 -10 to 24 -10 to 21
Soft Starter No No No No
18
Type
Model No.Indoor Unit ART25UUAN ART30UUAN ARY45UUANOutdoor Unit AOT25UNAKL AOT30UNBWL AOY45UMAXT
Reverse Cycle System Yes Yes YesOptional Simple Wired RC UTB-TPB UTB-TPB UTB-TPBOptional Remote Sensor UTD-RS100 UTD-RS100 UTD-RS100
Cooling CapacityWatts 7100 8500 12700
BTU/h 24100 29400 43400
Heating CapacityWatts 7700 9500 14300
BTU/h 26300 32400 48800Power Supply Volts 240 240 415Phase-Frequency Ph- Hz 1-50 1-50 3-50Power Supply Attachment Outdoor Outdoor Outdoor
Running Current Cooling Amps 11.8 14.3 7.7Heating Amps 10.5 13.1 7.7
InputCooling Watts 2650 3150 4380Heating Watts 2380 2800 4390
Moisture Removal l/hr 2.5 3 5.5 E.E.R. Cooling 2.68 2.7 2.90 C.O.P. Heating 3.24 3.39 3.26
Star RatingCooling ★★★ ★★★ -Heating ★★★★ ★★★★★■ -
Fan Speeds 3 3 3Ex Static Pressue Range Pa 30 to 150 30 to 150 30 to 150Air Circulation High l/s 320@100Pa 400@100Pa 500@100PaCompressor Type Rotary Rotary Scroll
Height mm 270 270 270I.U. Width mm 1135 1135 1135
Depth mm 700 700 700Dimensions Net Weight kg 43 43 45and Weights Height mm 650 830 1165
O.U. Width mm 830 900 900Depth mm 320 330 330Net Weight kg 59 69 113
Ductwork Plenum SizeSupply mm 1065 x 202 1065 x 202 1065 x 202Return mm 1015 x 240 1015 x 240 1015 x 240
Optional Supply SpigotsSquare Qty 1 UTD-SF045T UTD-SF045T UTD-SF045TRound Qty 4 UTD-RF204 UTD-RF204 UTD-RF204
I.U. Sound Pressure Level dBA@1mtr 39 41 44O.U. Sound Pressure Level dBA@1mtr 53 54 55O.U. Sound Power Level dBA 65 67 68Refrigerant Type R410A R410A R410A
Connection Pipe SizesGas mm 15.88 15.88 19.05Liquid mm 9.52 9.52 9.52
Pre Charged Length 7.5 7.5 20Minimum Pipe Length 5 5 5Maximum Pipe Length Metre 25 30 50Maximum Pipe Height Metre 15 15 30Pipe Connection Methods Flare Flare Flare
Outdoor Operating Temp.Cooling Degrees C 0 to 43 0 to 43 0 to 43Heating Degrees C -7 to 24 -7 to 24 -10 to 24
Soft Starter Yes Yes No
DUCTEDCONVENTIONAL
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 19
19
Type CONVENTIONAL
Model No.Indoor Unit ABT36UBAG ABT45UBAG ABT54UBAGOutdoor Unit AOT36UNAXT AOT45UMAXT AOT54UMAYT
Reverse Cycle System Yes Yes Yes
Cooling CapacityWatts 10500 12700 14500
BTU/h 35800 43400 49500
Heating CapacityWatts 12000 14300 16500
BTU/h 40900 48800 56300Power Supply Volts 415 415 415Phase-Frequency Ph- Hz 3-50 3-50 3-50Power Supply Attachment Outdoor Outdoor Outdoor
Running CurrentCooling Amps 6.1 7.7 9.7Heating Amps 6.2 7.7 9.8
InputCooling Watts 3550 4380 5230Heating Watts 3750 4390 5400
Moisture Removal l/hr 4 5 6E.E.R. Cooling 2.96 2.90 2.77 C.O.P. Heating 3.20 3.26 3.06
Star RatingCooling - - -Heating - - -
Fan Speeds 3 3 3Air Circulation High l/s 461 513 611Compressor Type Rotary Twin Rotary Scroll Scroll
Height mm 240 240 240I.U. Width mm 1660 1660 1660
Depth mm 700 700 700Dimensions Net Weight kg 48 48 48and Weights Height 830 1165 1165 1290
O.U. Width mm 900 900 900Depth mm 330 330 330Net Weight kg 94 113 118
- - -I.U. Sound Pressure Level dBA@1mtr 45 48 52O.U. Sound Pressure Level dBA@1mtr 55 55 55O.U. Sound Power Level dBA 68 68 68Refrigerant Type R410A R410A R410A
Connection Pipe SizesGas mm 15.88 19.05 19.05Liquid mm 9.52 9.52 9.52
Pre Charged Length 20 20 20Minimum Pipe Length Metre 5 5 5Maximum Pipe Length Metre 50 50 50Maximum Pipe Height Metre 30 30 30Pipe Connection Methods Flare Flare Flare
Outdoor operating Temp.Cooling Degrees C 0 to 43 0 to 43 0 to 43Heating Degrees C -10 to 24 -10 to 24 -10 to 24
LARGE UNDER CEILINGType CONVENTIONAL
Model No.Indoor Unit AUT36UUAS AUT45UUAS AUT54UUASOutdoor Unit AOT36UNAXT AOT45UMAXT AOT54UMAYT
Reverse Cycle System Yes Yes Yes
Cooling CapacityWatts 10500 12700 14500
BTU/h 35800 43400 49500
Heating CapacityWatts 12000 14300 16500
BTU/h 40900 48800 56300Power Supply Volts 415 415 415Phase-Frequency Ph- Hz 3-50 3-50 3-50Power Supply Attachment Outdoor Outdoor Outdoor
Running CurrentCooling Amps 6.1 7.7 9.7Heating Amps 6.4 7.7 9.8
InputCooling Watts 3550 4380 5230Heating Watts 3750 4390 5400
Moisture Removal l/hr 4 5 6E.E.R. Cooling 2.96 2.90 2.77C.O.P. Heating 3.20 3.26 3.06
Star RatingCooling - - -Heating - - -
Fan Speeds 3 3 3Air Circulation High l/s 430 444 486Compressor Type Twin Rotary Scroll Scroll
Height mm 296 296 296I.U. Width mm 830 830 830
Depth mm 830 830 830Dimensions Net Weight kg 37 40 40and Weights Height mm 1165 1165 1290
O.U. Width mm 900 900 900Depth mm 330 330 330Net Weight kg 94 113 118
Ceiling Opening Measurement mm 890 x 890 890 x 890 890 x 890I.U. Sound Pressure Level dBA@1mtr 48 49 52O.U. Sound Pressure Level dBA@1mtr 55 55 55O.U. Sound Power Level dBA 68 68 68Refrigerant Type R410A R410A R410A
Connection Pipe SizesGas mm 15.88 19.05 19.05Liquid mm 9.52 9.52 9.52
Pre Charged Length 20 20 20Minimum Pipe Length Metre 5 5 5Maximum Pipe Length Metre 50 50 50Maximum Pipe Height Metre 30 30 30Pipe Connection Methods Flare Flare Flare
Outdoor Operating Temp.Cooling Degrees C 0 to 43 0 to 43 0 to 43Heating Degrees C -10 to 24 -10 to 24 -10 to 24
CASSETTECONVENTIONAL
Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 20
FUJITSU GENERAL (AUST.) PTY LIMITEDACN 001 229 554
A Subsidiary of FUJITSU GENERAL LIMITEDwww.fujitsugeneral.com.au
HEAD OFFICENSW : 100 Holbeche Road Arndell Park N.S.W. 2148 TEL (02) 8822 2500 FAX (02) 8822 2501VIC/TAS : Unit 7, Lionel Business Park 14 Lionel Road Mount Waverley Vic. 3149
TEL (03) 9543 5899 FAX (03) 9543 8299QLD : 1 Breakfast Creek Rd, Newstead QLD. 4006
TEL (07) 3257 2800 FAX (07) 3257 2184SA/NT : 146 Fullarton Road Rose Park S.A. 5067 TEL (08) 8364 0588 FAX (08) 8364 0591WA : Suite 3, 5 Mumford Place Balcatta WA 6021 TEL (08) 9240 5877 FAX (08) 9240 5866
E-mail: [email protected] – or call 1300 882 201
Distributed by:
PRINTED IN AUSTRALIA TPBFG7079
Heating and cooling capacities are based on AS/NZS 3823.
Cooling Indoor Temp: 27°C DB/19°C WB Outdoor Temp: 35°C DB
Heating Indoor Temp: 20°C DBOutdoor Temp: 7°C DB /6°C WB
Running current is at rated conditions (AS3823) and does not include compressor start-up or variations in power supply and load conditions.
AUSTRALIA’S FAVOURITE A IRTM
Products in this brochure contain R410A, R407C or R22 refrigerant. Please refer to specifications before installation & servicing this product.
Only persons and/or companies qualified and experienced in theinstallation, service and repair of refrigerant products should be permittedto do so. The purchaser must ensure that the person and/or companywho is to install, service or repair this air conditioner has qualificationsand experience in refrigerant products.
Suitable access for warranty & service is required.
For future improvement, specifications, designs of product and availabilityare subject to change without notice. Please check with your dealer.
N807
All products specified in this brochure comply with the Australian Communications Authority’s (ACA) requirements for Electromagnetic Compatibility (EMC).
QAS is Accredited by the Joint Accreditation System of Australia and New Zealand,Acc No. S1250992AS
ISO 9002Certified number: JQA-2005
ISO 14001Certified number: EC98J1137
Hamamatsu Fujitsu General Ltd.