australia’s favourite air tm 2007fujitsu is australia’s favourite air. ... the highly efficient...

20
FUJITSU GENERAL ( AUST. ) PTY LIMITED AUSTRALIA’S FAVOURITE AIR TM Air Conditioning Range 2007 Ducted Cassette Large Under Ceiling Multi’s

Upload: dinhduong

Post on 30-Mar-2018

261 views

Category:

Documents


10 download

TRANSCRIPT

Page 1: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

FUJITSU GENERAL (AUST.) PTY LIMITED

A U S T R A L I A’S FA VO U R I T E A I R T M

Air Conditioning Range

2007Ducted

Cassette

Large Under Ceiling

Multi’s

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 2

Page 2: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

2

All over Australia, Fujitsu air conditioning is being installed in some of the most innovative and unusual building applications. That’s because oursystems offer incredible design flexibility, smoother more efficient controland lower running costs.So whether you need to air condition a few rooms or a few towers, Fujitsu has the solution. No wonder it’s Australia’s Favourite Air.

If it can be designed, we can air conditio

Features

Up/Down Swing LouvreThe up/down louvre automaticallyswings up and down.

Right/Left Swing LouvreThe right/left louvre automaticallyswings in either direction.

Double Swing AutomaticComplex swing action of the louvresenables them to swing automatically inboth horizontal and vertical directions.

Automatic LouvreThe position of the louvres is setautomatically to match the operatingmode. It is also possible to adjust thelouvres using the remote control.

Auto Shut LouvreThe auto shut louvres close or openautomatically when the unit stops or starts.

Automatic Air Flow AdjustmentWhen auto mode is selected for thefan, the micro-processor adjusts the airflow to follow changes in room temperature.

Auto RestartShould there be temporary loss ofpower; the unit will automaticallyrestart itself in the same operatingmode, once the power is restored.

Auto-ChangeoverThe unit automatically switchesbetween heating and cooling modesbased on the temperature setting and room temperature.

Sleep TimerThe micro-processor gradually changesthe room temperature, allowing you tosleep comfortably at night.

Program TimerThis timer allows selection of one offour options. ON, OFF, ON ––> OFF, or OFF ––> ON.

ON-OFF TimerON-OFF timer can be set to operateonce every 24 hours.

Weekly TimerDifferent on-off times can be set for up to 7 days.

Weekly + setback TimerWeekly + Setback timer can settemperature for two time spans and foreach day of the week.

Connectable Distributing DuctConditioned air can be distributed toadjacent areas by means of adistribution duct.

Connectable Fresh Air DuctAllows introduction of fresh air to

occupied space.

Fresh air intakeFresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts).*Selected ducted units only

Control Port External inputs and outputs containedwithin the product allow on/offcontrol, fresh air interlock connectionand heater bank element connection.UTD-ECS5A* (optional parts) * Selected ducted units only.

Cooling

Heating

TESAWTop Energy Saver Award for the mostenergy efficient star rated products.www.energyallstars.gov.au

V-PAMV-Pam Inverter technology increases the maximum output of thecompressor significantly and enableshigh power and high efficiency.

I-PAMI-Pam inverter technology enables high output and high efficiencyperformance.

Soft StarterAllows economical and quietcompressor start up for conventionalmodels. Inverter control of compressorin Inverter models does not require itto have a soft starter.

Washable Panel

CPON/OFF

Soft start

C

H

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 3

Page 3: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

3

n air condition it.

“With over 100 different brands of air conditioners on the market, how do you

know you’re choosing the right one? Well, my advice is to go with a name you can

trust, which is why I bought a Fujitsu.

No other company can match their wide range, exceptional economy and superior

efficiency. And with their famous 5 year parts and labour warranty, it’s no wonder

Fujitsu is Australia’s Favourite Air.”

Contents

ABOUT DUCTED SYSTEMS 4

INVERTER DUCTED TECHNOLOGY 5

INVERTER TYPE

DUCTED 6

CASSETTE 8

LARGE UNDER CEILING 8

MULTI’S 9

CONVENTIONAL TYPE

SLIM-LINE DUCTED 10

DUCTED 11

CASSETTE 12

LARGE UNDER CEILING 13

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 4

Page 4: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

4

Ducted Air ConditioningThe ultimate in air conditioning

Ducted air conditioning is surely the ultimate in comfort. The Fujitsu ducted models offer quiet,

efficient operation, are easy to maintain, and operated via a wall mounted LCD control that controls

all functions of the system.

Invisible comfort

Whatever shape of the room, ducted units create

uniform temperatures throughout. The unit is

totally concealed, usually within a ceiling void.

Cool or warm air is then ducted into each room

through outlets positioned in the walls, floor or

ceiling. Easily controlled, Fujitsu’s ducted systems

provide comfort throughout your house without

leaving cool or hot spots.

The ducted air conditioning system

• Perfect comfort throughout each room

• Visually appealing

• Concealed installation

• Reverse cycle heating and cooling

• Quiet operation

• Easy-to-use LCD controller

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 5

Page 5: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

Tem

p.

Set Temp.

Time

Temp.

Power

Tem

p.

Set Temp.

Time

Temp.

Power

On

OnOn

OffOff

CONVENTIONAL MODEL

RoomTemp.

Time

Set Temp.

Conventional

Inverter

T/2T

Room Warming Speed

DC twinrotarycompressor

Compressor COP100

90

80(%)

2 4 6 8

Cooling Capacity(kW)

COP

10 12

Comparison of cooling efficiency of DC compressor(against AC compressor)

AC Twin RotalyDC Twin Rotary

Power and Speed

INVERTER MODEL

The highly efficient DC Inverter twin rotary compressor can reach the room temperature you set up to

15% quicker than conventional models and precisely maintain temperature. The DC Inverter twin rotary

compressor makes operation at high power & high efficiency a reality. *(AOT30/36 models only)

The Inverter component allows

the outdoor unit to vary its speed

and output to match the required

capacity of the indoor unit.

Thus, the Inverter model can achieve

30% more operating efficiency than

conventional models and therefore,

is much cheaper to run.

5

Inverter Ducted TechnologyAs a world leader in energy efficient air conditioning systems, Fujitsu is committed to delivering highly

engineered inverter ducted systems. The new inverter ducted units feature an advanced scroll compressor

(AOT45/54L models only) to deliver optimum power without compromising on efficiency. Equipped with

sophisticated inverter technology, the Fujitsu inverter ducted systems are more economical to operate

and quieter to run than conventional units. The inverter component allows the outdoor unit to vary

its speed and output to match the required capacity of the indoor unit, making it up to 30% cheaper

to run than a conventional ducted system.

Fujitsu's inverter ducted air conditioning systems have been designed for easy installation in the

ceiling and roof space.

What's an inverter?

Through new, advanced technology, Inverter air conditioners are

more economical to operate and quieter to run than conventional

units. They can handle greater extremes in temperature, are

smoother and more stable in operation and reach the desired

temperature more quickly than conventional air conditioners.

Comparison of colloing efficiency of DC compressor(against AC compressor)

DC Inverter

Constant-Speed

50%Off

Approx.

Energy savings over one year

DC Inverter

Constant-Speed

Highly efficient R410A refrigerant

The R410A refrigerant, which is used in Fujitsu's Inverter ducted

systems, has zero ozone depletion potential as it contains no

chlorine. R410A also provides excellent stability and low toxity,

as well as offering superior energy saving.

Inverter control

DC twin rotary compressor*

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 6

Page 6: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

Wired remote controller with cover

Compact high static ducted features(LUAK/UUAK)

Temperature set back timer

Group control

One remote controller can control up to 16 air conditioners.

All of the air conditioners will be operated with the same settings.

Dual remote controllers (optional)

An additional controller can be added up to the maximum of two remote

controllers. Either remote controller can control the air conditioner.

However, the timer functions cannot be used at the slave unit.

Connectable quantity: Maximum 16 indoor units for 1 remote controller

Wired remote controller Example of ducted system configuration

Indoor Outdoor

Fresh air

Heater

Indoor

SET BACK temperatureON 28°c

24°c 24°c

OFF

NORMAL temperature

40cm

125cm80cm

40cm

105cm50cm

CURRENT MODEL: 75kg NEW MODEL: 50kg

Cobalt blue heat exchanger

The outdoor unit fins are coated with a blue corrosion

resistant material to enhance durability and extend

performance life of your air conditioner.

Use this timer function to change the set temperature

in the operation times set for each day of the week.

This can be used together with other timer settings.

Commercial mode

By enabling the indoor

unit’s internal controls,

you can achieve a

continual fan operation

in the heating mode, as

required for commercial

installations.

Child lock function

Simply pressing a combination of buttons

on the standard wired remote controller,

locks and unlocks the keypad, stopping

accidental and unauthorised use.

Simplified wired remote controller (optional)

This controller can be used as an optional slave

controller for dual comfort. It offers easier operation

and backlit display.

1. Fresh air output port. External fresh air fans can be

connected to run in conjunction with the fan motor of

the indoor unit.

2. Electrical heater output port. An External Electrical

heater can be set to operate in conjunction with the

heating cycle.

3. External input port. Start/stop of the air conditioner

can be controlled from external equipment.

Advanced features (UTD-ECS5A Required)

Hydrophillic coatingCobalt Blue protectionStandard cromate protectionAluminium base material

Detecting point can be changed easily

DAY NIGHT

Remote Sensor Opt

Wired Remote Controller

6

Room temperature sensor selection

• Remote controller has remote

sensor included.

• User can select between remote

controller sensor and/or

return air sensor or

remote sensor.

Remote Sensor in the bedroom

(effective at night)

Remote Controller in the living room

(effective during the day)

Example of ducted system configuration

Easy installation (compact size & light weight).

Size & weight have been reduced making installation considerably easier.

Operation sound (low noise)

The new ducted models have increased airflow volume

& decreased noise levels to 49dBA by adopting a

plastic case, plastic fan and three airflow volume

switch positions.

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 7

Page 7: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

7

INVERTER Ducted

ART30L

8.80kW / 30,000BTU/h

9.20kW / 31,400BTU/h

C

H

ART36L

10.00kW / 34,100BTU/h

10.00kW / 34,100BTU/h

C

H

ART45L

12.50kW / 42,700BTU/h

14.00kW / 47,800BTU/h

C

H

ART54L

14.50kW / 49,500BTU/h

16.00kW / 54,600BTU/h

C

H

ARY36L*

10.00kW / 34,100BTU/h

11.20kW / 38,250BTU/h

C

H

Wired type (with weekly/setback timer) For ARY36L

Wired type (with weekly/setback timer)

For ART45L/54L

For ART30L/36L

* Project order only. Minimum Delivery time 16 weeks

Control Features

Turbulent air flow is reduced by cutting off the corners of the conventional

indoor unit front panel and fan case. Uniform internal air pressure

decreases the noise level down to 41dBA (ART45L) and 42dBA (ART54L).

• Large air flow volume of 972 Litres/second (ART45/54L) is achieved

by adopting a larger fan. (Figures given at 100Pa).

• Low noise is achieved by use of a plastic case, plastic fan and

3-step airflow volume switch.

• Sirocco fan for airflow and indoor unit fan casing are also made

from plastic.

Operation sound (Low noise)

Current model NEW MODEL

Current model : Metal fan [53.1dB(A)]

* Model : Material (At 100Pa : Actual noise measurement value)

NEW MODEL : Plastic fan [41dB(A)]

800mm

Metal fan (ø240mm)

Casing (Metal Sheet)

40

0m

m

Heat exchangerPlastic fan

Casing (Plastic)

500mm

40

0m

m

ø225mmHeat exchanger

1 2 3

Various remote controllers and sensors can be

selected.

1. Wired Remote Controller with Thermo Sensor

• Room temperature sensor selection

• WEEKLY timer

• Temperature SET BACK timer

• Group control system

• Child lock

• Dual remote controllers (optional parts)

• AUTO restart

• Energy saving

• Auto changeover (for heating)

• Hot start (for heating)

2. Simple Remote Controller (optional parts)

3. Remote Sensor (optional parts)

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 8

Page 8: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

8

INVERTER Cassette

INVERTER Large Under Ceiling

Wired type (with weekly/setback timer) For AUT30L/36L For AUT45L/54L

AUT36L

10.0kW / 34,100BTU/h

11.2kW / 38,200BTU/h

C

H

AUT30L

8.5kW / 29,000BTU/h

10.0kW / 34,100BTU/h

C

H

AUT45L

12.5kW / 42,700BTU/h

14.0kW / 47,800BTU/h

C

H

AUT54L

14.0kW / 47,800BTU/h

16.0kW / 54,600BTU/h

C

H

ABT30L*

TBA

TBA

C

H

Control Features (AUT30/36/45/54L)

Duct connection hole opening

Easy maintenance (AUT30/36/45/54L)

Long-life filter

Various remote controllers and sensors can

be selected.

Wired Remote Controller with Thermo Sensor

• Room temperature sensor selection

• Temperature SET BACK timer

• Group control system

• Child lock

• Dual remote controllers (optional)

• Hot start (for heating)

The control box is easily accessible for maintenance work.

Wide opening for easy access. Detachable, washable filter

and intake grille. Wide opening and long-life filter.

High efficiency, long-life filter extends the cleaning cycle.Long life filter

Conditioned air can be distributed by means

of a distribution duct.

Distribution duct

Distribution duct

Fresh air

Fresh air can be introduced through this opening.

Fresh air can be introduced

through thisopening

Distribution duct Fresh air

Distributionduct

Two-way

Two-wayAUT30/36/45/54L

One-way

One-wayAUT30/36/45/54L

Condensate pump

For ABT30/36L For ABT45L

Ultra thin and wide air flow design for elegance and comfort.

Low noise realised

The outdoor unit’s fan shape (large

metal plate integrated bell mouth)

reduces the air flow resistance and

lowers noise levels (external fan

guard) so units are less obtrusive

to neighbours.

Improved installation/maintenance

Check joint standard equipment

Service port is provided at the high pressure side of the

refrigerant circuit. The operation of the air conditioning

refrigeration system can be checked by connecting a pressure

gauge, etc. and installation and maintenance work is improved.

Improved handling during installation

The new outdoor unit is equipped with handles at the front

and back at about the same height as the left and right so

that the unit can be easily carried during installation, etc.

* Due late 2007. Check with yourFujitsu dealer for availability.

Condensate pump lift to 800mm(AUT30/36/45/54L)

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 9

Page 9: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

Wall Mountedtype (Small Size)

Wall Mountedtype (Large Size)

Cassette type(Compact)

Floor/CeilingUniversal type

Duct type(Small size)

Duct type

AST7LM

AST9LM

AST12LM

AST18LB

AST24LB

AUT18LB

ABT24LB

ABT18LB

ABT14LBAUT14LB

AUT12LB

ART9L

AO

T3

0L

M4

AO

T2

4L

M2

AOT30LM4

AOT24LM21 outdoor unit to 2 indoor unitsThe total capacity of the indoor units that can be connected is 4.4 - 8.7kW(15,000 - 30,000BTU)

1 outdoor unit to 3–4 indoor unitsThe total capacity of the indoor units that can be connected is 7.9 - 14.3kW(27,000 - 49,000BTU)

2.3kW

2.7kW

3.5kW

4.2kW

5.2kW

6.3kW

6.8kW

(7,900BTU)

(9,200BTU)

(11,900BTU)

(14,300BTU)

(17,800BTU)

(21,500BTU)

(23,200BTU)

ART12L

ART14L

ART18L

ART22L

9

INVERTER Multi System

Wired type

ABT14/18/24LB

Universal Type

AUT12/14/18LB

Cassette Compact Type ART12/14/18/22L Duct TypeART9L Duct Type (small)

AST7/9/12LM

Wall Mounted Type

AST18/24LB

Wall Mounted Type

Wired type

AOT24LMAM2

5.8kW / 19,800BTU/h

6.4kW / 21,900BTU/h

C

H

AOT30LMAW4

8.00kW / 27,300BTU/h

9.60kW / 32,800BTU/h

C

H

New Model

AUT12L/14L/18LART9L/12L/14L/18L/22LABT14L/18L/24LAST7L/9L/12L/18L/24L

For AST18/24L only

The New Fujitsu Inverter Multi System is ideal where an

individual indoor unit is required in each room, i.e., a living

room and 3 bedrooms. The Multi Systems allows one

outdoor unit to be connected up to a wide variety of

3 or 4 indoor units including Wall Mounted, Floor/Ceiling

Console, Cassette and Ducted.

Refer to dealer for selection chart.

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 10

Page 10: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

10

CONVENTIONAL Ducted

Installation styles

(ART25/30/ARY45)

Low static pressure mode function (ART25/30 ARY45)

Slim & compact design

Optional functionfor comfort andoptional parts

(ART25/30/ARY45)

Year round comfort. A Fujitsu ducted system

provides air conditioned comfort to new and existing

homes. This means you can enjoy climate controlled

comfort all year round, all round the house.

ART25U

7.10kW / 24,100BTU/h

7.70kW / 26,300BTU/h

C

H

ART30U

8.50kW / 29,400BTU/h

9.50kW / 32,400BTU/h

C

H

ARY45U

12.70kW / 43,400BTU/h

14.30kW / 48,800BTU/h

C

H

Wired type (with weekly/setback timer) For ART25U For ART30U For ARY45U

Return air connection can be on the bottom

or rear of the indoor unit (Bottom connection

illustrated). Also, in addition to the already

slim height of the indoor unit at 270mm,

further size reduction is attained by reducing

65mm from the width with the flanking

control box imbedded inside the chassis.

1,200 1,135mm

270mm

Cm

The convexshaped controlbox is nowintegrated withinthe indoor unit(DIP Switch islocated on theinternalsubstrate.)

Static pressure (Pa)

1 2

0 70 100

Air

vo

lum

e(m

3/h

)

1. Low static pressure mode 1 air volume at 70Pa

(fan speed: high)

2. Normal Mode Air volume at 100Pa (fan speed:high)

When installed, normal middle static pressure mode and

low static pressure mode can be selected by switching

over using the DIP switch on the board in the control

box. Therefore, these models can be operated under a

wide range of conditions.

Other features

• Air intake position is selectable.

(Rear or Bottom)

• Air outlet shape is selectable at the

time of purchase. (Round or Square)

• Drain pipe position is selectable.

(Right or Left)

• Fresh air can be taken in.

Concealed ducted airconditioning system

• Perfect comfort throughout

each room.

• Visually appealing

• Concealed installation

• Reverse cycle heating & cooling

• Quiet operation

• Easy-to-use LCD remote controller

• Remote sensor (ART25/30/ARY45)

Optional partsRemote sensor unit UTD-RS100

Simple remote controller UTB-TPB

Flange (square) UTD-SF045T

Flange (round) UTD-RF204

Simple remote controllers (UTB-TPB)

1. Control box

2. Fan casing

3. Fan

4. Motor

Conventional model

2

4

1

3

Large bottom panel: 1 unit

New model

1

4

32

Bottom panel: 2 units

Conventional model

R SRemote sensor unit

(UTD-RS100)

Embedded

in ceiling

Hanging

in ceiling

One-touch operating and easy-to-install long-lifefilter (Optional Parts) – European model only.

Receiver unit &

Wireless Remote

Controller

New model

Easy maintenance

In the case of rear return air connection as illustrated below, structural improvement is

attained by making the bottom panel two pieces, front and rear. The internal fan casing

is also made dismountable in two pieces, namely, upper and lower sections. Motor and fan

maintenance and dismounting can be easily performed by removing the rear panel and

lower part of the casing with the main chassis installed.

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 11

Page 11: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

11

Remote Sensor in the bed room (effective at night)

Remote Cin the livin(effective

Remote Sensor in the bedroom(effective at night)

Remote Controller in the living room (effective during the day)

Wired type (with weekly/Setback timer)

ART36U

10.5kW / 36,000BTU/h

12.0kW / 40,980BTU/h

ART45U

12.7kW / 43,500BTU/h

14.3kW / 48,800BTU/h

ART60U

16.50kW / 56,300BTU/h

19.70kW / 67,200BTU/h

C

H

C

H

C

H

C

HWired type

(with weekly/Setback timer)

Accurate and Comfortable

• Comfortable room temperature control is available by

utilising the thermo sensor in the remote controller.

• Because the remote controller has a switching

function, the user can select which sensor is used.

(Room temperature sensor selection)

Example of roomtemperature sensorselection

Wired Remote Controller Remote Sensor (Optional Parts)The detecting point can be freely changed.

Day NightTHERMOSENSOR

Wired Remote Controller The detecting point can be freely changed. Remote Sensor (Optional Parts)

Sensor part

ART90T

26.40kW / 87,000BTU/h

29.50kW / 100,000BTU/h

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 12

Page 12: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

12

Simple maintenence

Control switches are

installed in the grille

for easy maintenance.

Detachable andwashable airintake grille

Wide opening.

Slender setting

250or

more

Standard setting

285or

more

Weekly timer

The sophisticated weekly timer and remote controller not

only makes it easy to adjust air conditioning units, but can

also help achieve considerable savings. It allows the air

conditioning system to be programmed in advance to

operate only as and when required.

The function of weekly timer

• Set different on/off times for each day of the week.

• Set two different on/off times for each day.

• Set time by 5 minute intervals.

• The timer operation of a reserved day can temporarily

be cancelled by pushing the “DAY OFF” button.

• If day function is used, weekly timer will resume next day.

• System can be manually over-riden.

Slender fit (2-way setting)

This new mechanism enables the cassette body to move 35mm

downward and allows installation into a 250mm space.

No special work or options are needed.

Elegant design

This ultra-thin air conditioner can

be installed in any narrow ceiling.

The fascia’s elegant design leaves the

air conditioner flush with the ceiling.

285 or

250

940

94

0

83

0

830

4-STEP SWING 4-STEP SWING

Refer tospecifications.Indoor unit holecut out size.

Swing louvres

The airflow direction, up or down is set automatically to match

the operating mode, i.e. down for heating, up for cooling.

4-Way air flow system

Slim size

The small and compact

body allows space

saving installation.

830mm

28

5m

m

30mm

2-way 3-way 4-way

CONVENTIONAL Cassette AUT36U

10.50kW / 35,800BTU/h

12.00kW / 40,900BTU/h

C

H

AUT45U

12.70kW / 43,400BTU/h

14.30kW / 48,800BTU/h

C

H

AUT54U

14.50kW / 49,500BTU/h

16.50kW / 56,300BTU/h

C

H

For AUT36U/45U

Wired type (with weekly/Setback timer)

For AUT54U

Efficient, simple, discreet. Incorporating the latest

fan technology, these units fit neatly into the ceiling

and distribute conditioned air through 2, 3 or 4 sides

of the unit. In addition, louvres allow air to be directed

in either a pre-set or sweep pattern.

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 13

Page 13: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

13

Large Under Ceiling

Quiet & Elegant. This lightweight, slim airconditioner fits directly under the ceiling. It is extremely quiet, yet extremely powerful. Because of their design, ceiling suspendedunits can be installed quickly, simply andwith minimum disruption.

CONVENTIONAL

ABT36U

10.50kW / 35,800BTU/h

12.00kW / 40,900BTU/h

C

H

ABT45U

12.70kW / 43,400BTU/h

14.30kW / 48,800BTU/h

C

H

ABT54U

14.50kW / 49,500BTU/h

16.50kW / 56,300BTU/h

C

H For ABT36U For ABT45U/54U

Fresh-air intake

Condensate water pump

The optional condensate water pump offers

more flexible installation by lifting the drain

and discharge point by 400mm.*

(optional)

*Refer to installation instructions.

OUTDOORINDOOR

Fresh Air

SWING

Double auto swing

Right and left

Control over air direction swing is possible through dual use of both an

up/down air direction swing and right/left air direction swing. Since up/down

air direction louvres operate automatically according to the operating mode

of the unit, it is possible to set air direction based on the operation mode.

SWING

Low noise realised

The outdoor unit’s fan shape (large metal

plate integrated bell mouth) reduces the

air flow resistance and lowers noise levels

(external fan guard) so units are less

obtrusive with neighbours.

WIDE AIR FLOW

Improved installation/maintenance

Check joint standard equipment

Service port is provided at the high pressure side

of the refrigerant circuit. The operation of the air

conditioning refrigeration system can be checked

by connecting a pressure gauge, etc. and

installation and maintenance work is improved.

Improved handling during installation

The new outdoor unit is equipped with handles at the front and back at about

the same height as the left and right so that the unit can be easily carried.

Features of new outdoor unit

(ABT36/45/54)

Up and down

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 14

Page 14: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

The Fujitsu Airstage VRF J Series is a breakthrough in compact VRF systems.

Ideal for larger domestic or smaller commercial applications, this system

offers many of the features found in Fujitsu’s renowned high-end

VRF systems, including quiet, efficient operation and Inverter Technology.

Our J series can also support up to 8 indoor units for every outdoor

unit, including ducted and ultra-thin ducted, cassette and slim-cassette,

and wall mounted split systems.

So talk to one of Fujitsu’s qualified Sales Engineers about your next

project. No matter what the building, we’ve got the solution.

If it can be designed, we can air condition it.

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 15

Page 15: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

When it comes to air conditioning

large buildings, Fujitsu General has the

solution. The new generation Airstage

V-Series. This high performance multi

air conditioning VRF solution is

designed to service a variety of

commercial applications and offers

many improvements on earlier systems.

To make installation easier, the Airstage

V-Series will allow pipe runs up to 150m

between indoor and outdoor units

and pipes of up to 60m long to be

connected between the first separation

tube and the furthest indoor unit.

Improvements to the compressor

operation and the introduction of a

primary inverter compressor mean the

V-Series is better equipped to maintain

a constant and comfortable indoor

environment. New compressor rotation

also equalizes the load on each

compressor to make the system more

durable and reliable. A three-way oil

control system further optimises

compressor efficiency.

For improved comfort, high precision

control technology allows the Airstage

V-Series to maintain the set room

temperature to within 0.5 degrees

Celsius.

The system offers design freedom by

allowing three outdoor units to be

connected together in series, and up

to 48 indoor units to be run on one

refrigerant piping system.

With a wide choice of indoor unit types,

the Airstage V-Series can be installed

in both new and existing buildings.

ir condition it.

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 16

Page 16: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

16

Type INVERTER

Model No.Indoor Unit ART30LUAK ART36LUAK ART45LUAK ART54LUAK ARY36LUANOutdoor Unit AOT30LMBDL AOT36LMADL AOT45LJBYL AOT54LJBYL AOY36LMBWL

Reverse Cycle System Yes Yes Yes Yes YesOptional Simple Wired RC UTB-TPB UTB-TPB UTB-TPB UTB-TPB UTB-TPBOptional Remote Sensor UTD-RS100 UTD-RS100 UTD-RS100 UTD-RS100 UTD-RS100

Cooling CapacityWatts 8800 10000 12500 14500 10000BTU/h 30000 34100 42700 49500 34100

RangeWatts 2700-9800 2700-10500 3600-14000 6400-15300 Max 11200BTU/h 9200-33500 9200-36000 12300-47800 21900-52200 Max 38200

Heating CapacityWatts 9200 10000 14000 16000 11200

BTU/h 31400 34100 47800 54600 38250

RangeWatts 3000-11000 3000-12100 4700-18000 6800-20000 Max 12770BTU/h 10200-37600 10200-41300 47800-61500 23200-68300 Max 43600

Power Supply Volts 240 240 240 240 240Phase-Frequency Ph- Hz 1-50 1-50 1-50 1-50 1-50Power Supply Attachment Outdoor Outdoor Outdoor Outdoor Outdoor

Running Current Cooling Amps 13.8 (4.6-17.3) 16.7(4.6-17.6) 18.1(7.1-21.7) 23.5 (7.1-25.3) 17.9 (Max 18.4)Heating Amps 10.7 (4.3-17.3) 11.7 (4.3-17.6) 16.0 (6.3-20.1) 19.8 (6.3-25.3) 13.9 (Max 18.4)

InputCooling Watts 3300 (1080-4150) 4000 (1080-4200) 4300 (1700-5200) 5570 (1700-6060) 4080 (Max 4200)Heating Watts 2550 (1000-4150) 2800 (1000-4200) 3800 (1500-4800) 4700 (1500-6060) 3180 (Max 4150)

Moisture Removal l/hr 3 3 3 4 3E.E.R. Cooling 2.67 2.5 2.91 2.6 2.45C.O.P. Heating 3.61 3.57 3.68 3.40 3.52

Star RatingCooling ★★★ ★★★■ ★★★★ ★★★ -Heating ★★★★★ ★★★★★ ★★★★★★■ ★★★★★■ -

Fan Speeds 3 3 3 3 3Ex Static Pressure Range Pa 100 to 200 100 to 200 100 to 250 100 to 250 30 to 150Air Circulation High l/s 694@100Pa 694@100Pa 972@100Pa 972@100Pa 486Compressor Type DC Twin Rotary DC Twin Rotary DC Scroll DC Scroll DC Twin Rotary

Height mm 400 400 400 400 270I.U. Width mm 1050 1050 1050 1050 1135

Depth mm 500 500 500 500 700Dimensions Net Weight kg 45 45 50 50 43and Weights Height mm 900 900 1290 1290 830

O.U. Width mm 900 900 900 900 900Depth mm 350 350 330 330 330Net Weight kg 70 70 105 105 64

Duct Work Plenum SizeSupply mm 850 x 295 850 x 295 850 x 295 850 x 295 1065 x 202Return mm 865 x 325 865 x 325 865 x 325 865 x 325 1015 x 240

Optional Supply SpigotsSquare Qty 1 - - - - UTD-SFO45TRound Qty 4 - - - - UTD-RF204

I.U. Sound Pressure Level dBA@1mtr 45 45 49 49 43O.U. Sound Pressure Level dBA@1mtr 53 53 54 54 54O.U. Sound Power Level dBA 65 65 65 69 66Refrigerant Type R410A R410A R410A R410A R410A

Connection Pipe SizesGas mm 15.88 15.88 15.88 15.88 15.88Liquid mm 9.52 9.52 9.52 9.52 9.52

Refrigerant Pre Charged Length Metre 10 10 20 20 15Minimum Pipe Length Metre 5 5 5 5 5Maximum Pipe Length Metre 30 30 70 70 50Maximum Pipe Height Metre 20 20 30 30 30Pipe Connection Methods Flare Flare Flare Flare Flare

Outdoor Operating Temp.Cooling Degrees C 0 to 43 0 to 43 -15 to 43 -15 to 43 -10 to 43Heating Degrees C -10 to 21 -10 to 21 -15 to 24 -15 to 24 -10 to 24

DUCTEDINVERTER

Type WALL MOUNTED FLOOR/CEILING CASSETTE

Model No.Indoor Unit AST7LMACW AST9LMACW AST12LMACW AST18LBAJ AST24LBAJ ABT14LBAJ ABT18LBAJ ABT24LBAJ AUT12LBAB AUT14LBAB AUT18LBABOutdoor Unit - - - - - - - - - - -

Reverse Cycle System Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Cooling CapacityWatts 2300 2700 3500 5200 6800 4200 5200 6800 3500 4000 4300

BTU/h 7900 9200 11900 17800 23200 14300 17800 23200 11900 13700 14700

Maximum Watts 2700 3400 3700 6000 7400 5000 6000 7400 3800 4500 5200

BTU/h 9200 11600 12600 20500 25300 17200 20500 25300 13000 15400 17800

Heating CapacityWatts 2700 3300 3800 6000 8200 4800 6000 8200 3800 4300 5000

BTU/h 9200 11300 13000 20500 28000 16400 20500 28000 13000 14700 17100

Maximum Watts 3300 3700 4500 7100 9000 5700 7100 9000 4500 5200 6300

BTU/h 11300 12600 15400 24200 30700 19500 24200 30700 15400 17800 21150Power Supply Volts 240 240 240 240 240 240 240 240 240 240 240Phase-Frequency Ph- Hz 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50Power Supply Attachment Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor OutdoorPlug Size (If Applicable) - - - - - - - - - - -

Cooling Amps - - - - - - - - - - -

Running Current Range Amps - - - - - - - - - - -Heating Amps - - - - - - - - - - -Range Amps - - - - - - - - - - -Cooling Watts - - - - - - - - - - -

InputRange Watts - - - - - - - - - -Heating Watts - - - - - - - - - - -Range Watts - - - - - - - - - - -

Moisture Removal l/hr 1 1.2 1.6 3 3 1.5 1.7 2.5 1.3 1.5 2E.E.R. Cooling - - - - - - - - - - -C.O.P. Heating - - - - - - - - - - -

Star RatingCooling - - - - - - - - - - -Heating - - - - - - - - - -

Fan Speeds 4 4 4 4 4 3 3 3 3 3 3Air Circulation High l/s 119 130 144 263 283 177 216 244 152 152 172Compressor Type - - - - - - - - - - -

Height mm 257 257 257 320 320 199 199 199 235 235 235

I.U.Width mm 808 808 808 1120 1120 990 990 990 580 580 580Depth mm 187 187 187 220 220 655 655 655 580 580 580

Dimensions Net Weight kg 8 8 8 16 16 28 28 28 18 18 18and Weights Height mm - - - - - - - - - - -

O.U. Width mm - - - - - - - - - - -Depth mm - - - - - - - - - - -Net Weight kg - - - - - - - - - - -

I.U. Sound Pressure Level dBA@1mtr 34 36 38 43 47 36 43 48 42 42 44O.U. Sound Pressure Level dBA@1mtr - - - - - - - - - - -O.U. Sound Power Level dBA - - - - - - - - - - -Refrigerant Type R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A

Connection Pipe SizesGas mm 9.52 9.52 9.52 12.7 15.88 12.7 12.7 15.88 9.52 12.7 12.7Liquid mm 6.35 6.35 6.35 6.35 9.52 6.35 6.35 9.52 6.35 6.35 6.35

Pre Charged Length Metre - - - - - - - - - - -Minimum Pipe Length (per unit) Metre - - - - - - - - - - -Maximum Pipe Length (per unit) Metre - - - - - - - - - - -Maximum Pipe Length Metre 25 25 25 25 25 25 25 25 25 25 25Maximum Pipe Height Metre 10 10 10 10 10 10 10 10 10 10 10Pipe Connection Methods Flare Flare Flare Flare Flare Flare Flare Flare Flare Flare Flare

Outdoor Operating Temp.Cooling Degrees C - - - - - - - - - - -Heating Degrees C - - - - - - - - - - -

MULTI SYSTEM INVERTERINVERTER

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 17

Page 17: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

17

Type OUTDOOR

Model No.Indoor Unit - -Outdoor Unit AOT30LMAW4 AOT24LMAM2

Reverse Cycle System Yes Yes

Cooling CapacityWatts 8000 5800

BTU/h 27300 19800

Maximum CapacityWatts 10100 7800

BTU/h 34500 26600

Heating CapacityWatts 9600 6400

BTU/h 32800 21900

Maximum CapacityWatts 12000 9000

BTU/h 41000 30700Power Supply Volts 240 240Phase-Frequency Ph- Hz 1-50 1-50Power Supply Attachment Outdoor OutdoorPlug Size (If Applicable) N/A N/A

Running Current Cooling Amps 9.3 7.3

Max 15.7 Max 12.2Heating Amps 10.1 6.9

Max 15.7 Max 12.2

InputCooling Watts 2220 1730

Max 3580 Max 2920Heating Watts 2400 1640

Moisture Removal l/hr Max 3580 Max 2920- -

E.E.R. Cooling 3.6 3.35C.O.P. Heating 4 3.9

Star RatingCooling - -Heating - -

Fan Speeds - -Air Circulation High l/s 972 805Compressor Type Twin Rotary Twin Rotary

Height mm - -

I.U. Width mm - -Depth mm - -

Dimensions Net Weight kg - -and Weights Height mm 835 650

O.U. Width mm 900 830Depth mm 330 320Net Weight kg 68 56

I.U. Sound Pressure Level dBA@1mtr - -O.U. Sound Pressure Level dBA@1mtr 51 49O.U. Sound Power Level dBA 64 62Refrigerant Type R410A R410A

Connection Pipe SizesGas mm 2 x 9.52, 2 x 12.7 1 x 12.7, 1 x 9.52Liquid mm 4 x 6.35 2 x 6.35

Pre Charged Length 50 30Minimum Pipe Length (per unit) Metre 5 5Maximum Pipe Length (per unit) Metre 25 20Maximum Pipe Length Metre Max Total 70 Max Total 30Maximum Pipe Height Metre 10 10Pipe Connection Methods Flare Flare

Outdoor operating Temp.Cooling Degrees C 0 to 43 0 to 43Heating Degrees C -10 to 24 -10 to 24

Type BULKHEAD

Model No.Indoor Unit ART9LUAB ART12LUAD ART14LUAD ART18LUAD ART22LUADOutdoor Unit - - - - -

Reverse Cycle System Yes Yes Yes Yes Yes

Cooling CapacityWatts 2700 3500 4200 5200 6300

BTU/h 9200 11900 14300 17800 21500

Maximum CapacityWatts 3300 4000 5000 6000 6800

BTU/h 11300 13600 17100 20500 23200

Heating CapacityWatts 3300 3800 4800 6000 7500

BTU/h 11300 13000 16400 20500 25600

Maximum CapacityWatts 3600 4500 5800 7100 8800

BTU/h 12300 15400 19800 24200 30000Power Supply Volts 240 240 240 240 240Phase-Frequency Ph- Hz 1-50 1-50 1-50 1-50 1-50Power Supply Attachment Outdoor Outdoor Outdoor Outdoor OutdoorPlug Size (If Applicable) - - - - -

Running Current Cooling Amps - - - - -Heating Amps - - - - -

InputCooling Watts - - - - -Heating Watts - - - - -

- - - - -- - - - -- - - - -- - - - -

Moisture Removal l/hr 1 1.2 1.5 1.7 2.5E.E.R. Cooling - - - - -C.O.P. Heating - - - - -

Star RatingCooling - - - - -Heating - - - - -

Fan Speeds 3 3 3 3 3Air Circulation High l/s 125 161 216 222 288Compressor Type - - - - -

Height mm 217 217 217 217 217I.U. Width mm 663 953 953 953 953

Depth mm 595 595 595 595 595Dimensions Net Weight kg 18 25 25 25 25and Weights Height mm - - - - -

O.U. Width mm - - - - -Depth mm - - - - -Net Weight kg - - - - -

I.U. Sound Pressure Level dBA@1mtr 39 33 40 41 46O.U. Sound Pressure Level dBA@1mtr - - - - -O.U. Sound Power Level dBA - - - - -Refrigerant Type R410A R410A R410A R410A R410A

Connection Pipe SizesGas mm 9.52 9.52 12.7 12.7 12.7Liquid mm 6.35 6.35 6.35 6.35 6.35

Pre Charged Length - - - - -Minimum Pipe Length (per unit) Metre - - - - -Maximum Pipe Length (per unit) Metre - - - - -Maximum Pipe Length Metre 25 25 25 25 25Maximum Pipe Height Metre 10 10 10 10 10Pipe Connection Methods Flare Flare Flare Flare Flare

Outdoor operating Temp.Cooling Degrees C - - - - -Heating Degrees C - - - - -

CASSETTET24LBAJ AUT12LBAB AUT14LBAB AUT18LBAB

- - - -Yes Yes Yes Yes

6800 3500 4000 43003200 11900 13700 147007400 3800 4500 52005300 13000 15400 17800

8200 3800 4300 50008000 13000 14700 17100

9000 4500 5200 63000700 15400 17800 21150240 240 240 2401-50 1-50 1-50 1-50utdoor Outdoor Outdoor Outdoor

- - - -- - - -- - - -- - - -- - - -- - - -- - -- - - -- - - -

2.5 1.3 1.5 2- - - -- - - -- - - -- - -3 3 3 3

244 152 152 172- - - -

199 235 235 235990 580 580 580655 580 580 58028 18 18 18- - - -- - - -- - - -- - - -

48 42 42 44- - - -- - - -

R410A R410A R410A R410A5.88 9.52 12.7 12.79.52 6.35 6.35 6.35

- - - -- - - -- - - -

25 25 25 2510 10 10 10

Flare Flare Flare Flare- - - -- - - -

Type INVERTER

Model No.Indoor Unit ABT30LBAG ABT36LBAG ABT45LBAGOutdoor Unit TBA TBA TBA

Reverse Cycle System Yes Yes Yes

Cooling CapacityWatts TBA TBA TBABTU/h TBA TBA TBA

Heating CapacityWatts TBA TBA TBA

BTU/h TBA TBA TBAPower Supply Volts TBA TBA TBAPhase-Frequency Ph- Hz TBA TBA TBAPower Supply Attachment TBA TBA TBA

Running CurrentCooling Amps TBA TBA TBAHeating Amps TBA TBA TBA

InputCooling Watts TBA TBA TBAHeating Watts Outdoor Outdoor Outdoor

Moisture Removal l/hr TBA TBA TBAE.E.R. Cooling TBA TBA TBAC.O.P. Heating TBA TBA TBA

Star RatingCooling TBA TBA TBAHeating TBA TBA TBA

Fan Speeds TBA TBA TBAAir Circulation High l/s TBA TBA TBACompressor Type TBA TBA TBA

Height mm TBA TBA TBAI.U. Width mm TBA TBA TBA

Depth 830 TBA TBA TBADimensions Net Weight kg TBA TBA TBAand Weights Height mm TBA TBA TBA

O.U. Width mm TBA TBA TBADepth mm TBA TBA TBANet Weight kg TBA TBA TBA

I.U. Sound Pressure Level dBA@1mtr TBA TBA TBAO.U. Sound Pressure Level dBA@1mtr TBA TBA TBAO.U. Sound Power Level dBA TBA TBA TBARefrigerant Type TBA TBA TBA

TBA TBA TBA

Connection Pipe SizesGas mm TBA TBA TBALiquid mm TBA TBA TBA

Pre Charged Length TBA TBA TBAMinimum Pipe Length Metre R410A R410A R410AMaximum Pipe Length Metre TBA TBA TBAMaximum Pipe Height Metre TBA TBA TBAPipe Connection Methods TBA TBA TBA

Outdoor operating Temp.Cooling Degrees C TBA TBA TBAHeating Degrees C TBA TBA TBA

TBA TBA TBA TBA TBA TBA TBAFlare Flare FlareTBA TBA TBATBA TBA TBA

LARGE UNDER CEILINGType INVERTER

Model No.Indoor Unit AUT30LUAS AUT36LUAS AUT45LUAS AUT54LUASOutdoor Unit AOT30LNAWL AOT36LNAWL AOT45LJBYL AOT54LJBYL

Reverse Cycle System Yes Yes Yes Yes

Cooling CapacityWatts 8500 10000 12500 14000BTU/h 29000 34100 42700 47800

RangeWatts 3000-10000 5000-11200 3000-14000 6400-14500BTU/h 10200-34100 17000-38200 10200-47800 21800-49500

Heating CapacityWatts 10000 11200 14000 16000

BTU/h 34100 38200 47800 54600

RangeWatts 3000-11200 5150-12770 3000-16000 6800-16500BTU/h 10200-38200 17600-43300 10200-54600 23200-56300

Power Supply Volts 240 240 240 240Phase-Frequency Ph- Hz 1-50 1-50 1-50 1-50Power Supply Attachment Outdoor Outdoor Outdoor Outdoor

Running CurrentCooling Amps 12 (4.6-14.6) 16.8 (4.6-17.5) 18.6 (7.1-22.6) 23.5 (7.1-24.0)

Heating Amps 11.9 (4.3-14.6) 14.6 (4.3-17.5) 16.6 (6.3-20.0) 20.4 (6.3-21.8)

InputCooling Watts 2860 (1080-3500) 4010 (1080-4200) 4450 (1700-5150) 5600 (1700-5700)

Heating Watts 2840 (1000-3500) 3490 (1000-4200) 3950 (1500-4600) 4850 (1500-5200)

Moisture Removal l/hr 3 4 4.5 5.5E.E.R. Cooling 2.97 2.49 2.81 2.50 C.O.P. Heating 3.52 3.21 3.54 3.30

Star RatingCooling ★★★★ ★★★■ ★★★★■ ★★★■Heating ★★★★★ ★★★★ ★★★★★ ★★★★

Fan Speeds 3 3 3 3Air Circulation High l/s 444 444 486 486Compressor Type DC Twin Rotary DC Twin Rotary DC Scroll DC Scroll

Height mm 296 296 296 296I.U. Width mm 830 830 830 830

Depth mm 830 830 830 830Dimensions Net Weight kg 37 37 40 40and Weights Height mm 830 830 1290 1290

O.U. Width mm 900 900 900 900Depth mm 330 330 330 330Net Weight kg 64 64 105 105

Ceiling Opening Measurement mm 890 x 890 890 x 890 890 x 890 890 x 890I.U. Sound Pressure Level dBA@1mtr 48 48 51 51O.U. Sound Pressure Level dBA@1mtr 53 54 54 54O.U. Sound Power Level dBA 65 65 66 66Refrigerant Type R410A R410A R410A R410A

Connection Pipe SizesGas mm 15.88 15.88 15.88 15.88Liquid mm 9.52 9.52 9.52 9.52

Pre Charged Length Metre 15 15 20 20Minimum Pipe Length Metre 5 5 5 5Maximum Pipe Length Metre 50 50 70 70Maximum Pipe Height Metre 30 30 30 30Pipe Connection Methods Flare Flare Flare Flare

Outdoor Operating Temp.Cooling Degrees C -10 to 43 -10 to 43 -15 to 43 -15 to 43Heating Degrees C -10 to 24 -10 to 24 -15 to 24 -15 to 24

CASSETTEINVERTER

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 18

Page 18: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

Type CONVENTIONAL

Model No.Indoor Unit ART36UUAK ART45UUAK ART60UUAK ART90TUAJOutdoor Unit AOT36UNAXT AOT45UMAXT AOT60UMAYT AOT90TPC3L

Reverse Cycle System Yes Yes Yes YesOptional Simple Wired RC UTB-TPB UTB-TPB UTB-TPB UTB-TPBOptional Remote Sensor UTD-RS100 UTD-RS100 UTD-RS100 UTD-RS100

Cooling CapacityWatts 10500 12700 16500 26400

BTU/h 36000 43500 56300 87000

Heating CapacityWatts 12000 14300 19700 29500

BTU/h 40980 48800 67200 100000Power Supply Volts 415 415 415 415Phase-Frequency Ph- Hz 3-50 3-50 3-50 3-50Power Supply Attachment Outdoor Outdoor Outdoor Indoor & Outdoor

Running CurrentCooling Amps 6.2 7.8 10.9 19.5Heating Amps 6.2 7.7 10.6 19.5

InputCooling Watts 3750 4550 6200 10100Heating Watts 3450 4200 5750 10100

Moisture Removal l/hr 2 3 4 7.5E.E.R. Cooling 2.80 2.79 2.66 2.61 C.O.P. Heating 3.48 3.40 3.43 2.92

Star RatingCooling - - - -Heating - - - -

Fan Speeds 3 3 3 1Ex Static Pressue Range Pa 100 to 200 100 to 200 100 to 250 100 to 300Air Circulation High l/s 720@100Pa 750@100Pa 1000@100Pa 1200@200PaCompressor Type Twin Rotary Scroll Scroll Scroll

Height mm 400 400 400 450

I.U.Width mm 1050 1050 1050 1550Depth mm 500 500 500 700

Dimensions Net Weight kg 50 50 50 85and Weights Height mm 1165 1165 1290 1380

O.U. Width mm 900 900 900 1300Depth mm 330 330 330 650Net Weight kg 94 113 118 245

Ductwork Plenum SizeSupply mm 850 x 295 850 x 295 850 x 295 1200 x 350Return mm 865 x 325 865 x 325 865 x 325 1250 x 370

Optional Supply SpigotsSquare Qty 1 - - - -Round Qty 4 - - - -

I.U. Sound Pressure Level dBA@1mtr 44 45 49 50O.U. Sound Pressure Level dBA@1mtr 55 55 55 59O.U. Sound Power Level dBA 68 68 68 70Refrigerant Type R410A R410A R410A R407C

Connection Pipe SizesGas mm 15.88 19.05 19.05 28.58Liquid mm 9.52 9.52 9.52 12.7

Pre Charged Length 20 20 20 30Minimum Pipe Length 5 5 5 5Maximum Pipe Length Metre 50 50 50 50Maximum Pipe Height Metre 30 30 30 30Pipe Connection Methods Flare Flare Flare Flare & Flange

Outdoor operating Temp.Cooling Degrees C 0 to 43 0 to 43 0 to 43 0 to 46Heating Degrees C -10 to 24 -10 to 24 -10 to 24 -10 to 21

Soft Starter No No No No

18

Type

Model No.Indoor Unit ART25UUAN ART30UUAN ARY45UUANOutdoor Unit AOT25UNAKL AOT30UNBWL AOY45UMAXT

Reverse Cycle System Yes Yes YesOptional Simple Wired RC UTB-TPB UTB-TPB UTB-TPBOptional Remote Sensor UTD-RS100 UTD-RS100 UTD-RS100

Cooling CapacityWatts 7100 8500 12700

BTU/h 24100 29400 43400

Heating CapacityWatts 7700 9500 14300

BTU/h 26300 32400 48800Power Supply Volts 240 240 415Phase-Frequency Ph- Hz 1-50 1-50 3-50Power Supply Attachment Outdoor Outdoor Outdoor

Running Current Cooling Amps 11.8 14.3 7.7Heating Amps 10.5 13.1 7.7

InputCooling Watts 2650 3150 4380Heating Watts 2380 2800 4390

Moisture Removal l/hr 2.5 3 5.5 E.E.R. Cooling 2.68 2.7 2.90 C.O.P. Heating 3.24 3.39 3.26

Star RatingCooling ★★★ ★★★ -Heating ★★★★ ★★★★★■ -

Fan Speeds 3 3 3Ex Static Pressue Range Pa 30 to 150 30 to 150 30 to 150Air Circulation High l/s 320@100Pa 400@100Pa 500@100PaCompressor Type Rotary Rotary Scroll

Height mm 270 270 270I.U. Width mm 1135 1135 1135

Depth mm 700 700 700Dimensions Net Weight kg 43 43 45and Weights Height mm 650 830 1165

O.U. Width mm 830 900 900Depth mm 320 330 330Net Weight kg 59 69 113

Ductwork Plenum SizeSupply mm 1065 x 202 1065 x 202 1065 x 202Return mm 1015 x 240 1015 x 240 1015 x 240

Optional Supply SpigotsSquare Qty 1 UTD-SF045T UTD-SF045T UTD-SF045TRound Qty 4 UTD-RF204 UTD-RF204 UTD-RF204

I.U. Sound Pressure Level dBA@1mtr 39 41 44O.U. Sound Pressure Level dBA@1mtr 53 54 55O.U. Sound Power Level dBA 65 67 68Refrigerant Type R410A R410A R410A

Connection Pipe SizesGas mm 15.88 15.88 19.05Liquid mm 9.52 9.52 9.52

Pre Charged Length 7.5 7.5 20Minimum Pipe Length 5 5 5Maximum Pipe Length Metre 25 30 50Maximum Pipe Height Metre 15 15 30Pipe Connection Methods Flare Flare Flare

Outdoor Operating Temp.Cooling Degrees C 0 to 43 0 to 43 0 to 43Heating Degrees C -7 to 24 -7 to 24 -10 to 24

Soft Starter Yes Yes No

DUCTEDCONVENTIONAL

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 19

Page 19: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

19

Type CONVENTIONAL

Model No.Indoor Unit ABT36UBAG ABT45UBAG ABT54UBAGOutdoor Unit AOT36UNAXT AOT45UMAXT AOT54UMAYT

Reverse Cycle System Yes Yes Yes

Cooling CapacityWatts 10500 12700 14500

BTU/h 35800 43400 49500

Heating CapacityWatts 12000 14300 16500

BTU/h 40900 48800 56300Power Supply Volts 415 415 415Phase-Frequency Ph- Hz 3-50 3-50 3-50Power Supply Attachment Outdoor Outdoor Outdoor

Running CurrentCooling Amps 6.1 7.7 9.7Heating Amps 6.2 7.7 9.8

InputCooling Watts 3550 4380 5230Heating Watts 3750 4390 5400

Moisture Removal l/hr 4 5 6E.E.R. Cooling 2.96 2.90 2.77 C.O.P. Heating 3.20 3.26 3.06

Star RatingCooling - - -Heating - - -

Fan Speeds 3 3 3Air Circulation High l/s 461 513 611Compressor Type Rotary Twin Rotary Scroll Scroll

Height mm 240 240 240I.U. Width mm 1660 1660 1660

Depth mm 700 700 700Dimensions Net Weight kg 48 48 48and Weights Height 830 1165 1165 1290

O.U. Width mm 900 900 900Depth mm 330 330 330Net Weight kg 94 113 118

- - -I.U. Sound Pressure Level dBA@1mtr 45 48 52O.U. Sound Pressure Level dBA@1mtr 55 55 55O.U. Sound Power Level dBA 68 68 68Refrigerant Type R410A R410A R410A

Connection Pipe SizesGas mm 15.88 19.05 19.05Liquid mm 9.52 9.52 9.52

Pre Charged Length 20 20 20Minimum Pipe Length Metre 5 5 5Maximum Pipe Length Metre 50 50 50Maximum Pipe Height Metre 30 30 30Pipe Connection Methods Flare Flare Flare

Outdoor operating Temp.Cooling Degrees C 0 to 43 0 to 43 0 to 43Heating Degrees C -10 to 24 -10 to 24 -10 to 24

LARGE UNDER CEILINGType CONVENTIONAL

Model No.Indoor Unit AUT36UUAS AUT45UUAS AUT54UUASOutdoor Unit AOT36UNAXT AOT45UMAXT AOT54UMAYT

Reverse Cycle System Yes Yes Yes

Cooling CapacityWatts 10500 12700 14500

BTU/h 35800 43400 49500

Heating CapacityWatts 12000 14300 16500

BTU/h 40900 48800 56300Power Supply Volts 415 415 415Phase-Frequency Ph- Hz 3-50 3-50 3-50Power Supply Attachment Outdoor Outdoor Outdoor

Running CurrentCooling Amps 6.1 7.7 9.7Heating Amps 6.4 7.7 9.8

InputCooling Watts 3550 4380 5230Heating Watts 3750 4390 5400

Moisture Removal l/hr 4 5 6E.E.R. Cooling 2.96 2.90 2.77C.O.P. Heating 3.20 3.26 3.06

Star RatingCooling - - -Heating - - -

Fan Speeds 3 3 3Air Circulation High l/s 430 444 486Compressor Type Twin Rotary Scroll Scroll

Height mm 296 296 296I.U. Width mm 830 830 830

Depth mm 830 830 830Dimensions Net Weight kg 37 40 40and Weights Height mm 1165 1165 1290

O.U. Width mm 900 900 900Depth mm 330 330 330Net Weight kg 94 113 118

Ceiling Opening Measurement mm 890 x 890 890 x 890 890 x 890I.U. Sound Pressure Level dBA@1mtr 48 49 52O.U. Sound Pressure Level dBA@1mtr 55 55 55O.U. Sound Power Level dBA 68 68 68Refrigerant Type R410A R410A R410A

Connection Pipe SizesGas mm 15.88 19.05 19.05Liquid mm 9.52 9.52 9.52

Pre Charged Length 20 20 20Minimum Pipe Length Metre 5 5 5Maximum Pipe Length Metre 50 50 50Maximum Pipe Height Metre 30 30 30Pipe Connection Methods Flare Flare Flare

Outdoor Operating Temp.Cooling Degrees C 0 to 43 0 to 43 0 to 43Heating Degrees C -10 to 24 -10 to 24 -10 to 24

CASSETTECONVENTIONAL

Fujitsu07COMMERCIAL_ART.qxd 9/3/07 2:51 PM Page 20

Page 20: AUSTRALIA’S FAVOURITE AIR TM 2007Fujitsu is Australia’s Favourite Air. ... The highly efficient DC Inverter twin rotary compressor can reach ... Fujitsu's inverter ducted air conditioning

FUJITSU GENERAL (AUST.) PTY LIMITEDACN 001 229 554

A Subsidiary of FUJITSU GENERAL LIMITEDwww.fujitsugeneral.com.au

HEAD OFFICENSW : 100 Holbeche Road Arndell Park N.S.W. 2148 TEL (02) 8822 2500 FAX (02) 8822 2501VIC/TAS : Unit 7, Lionel Business Park 14 Lionel Road Mount Waverley Vic. 3149

TEL (03) 9543 5899 FAX (03) 9543 8299QLD : 1 Breakfast Creek Rd, Newstead QLD. 4006

TEL (07) 3257 2800 FAX (07) 3257 2184SA/NT : 146 Fullarton Road Rose Park S.A. 5067 TEL (08) 8364 0588 FAX (08) 8364 0591WA : Suite 3, 5 Mumford Place Balcatta WA 6021 TEL (08) 9240 5877 FAX (08) 9240 5866

E-mail: [email protected] – or call 1300 882 201

Distributed by:

PRINTED IN AUSTRALIA TPBFG7079

Heating and cooling capacities are based on AS/NZS 3823.

Cooling Indoor Temp: 27°C DB/19°C WB Outdoor Temp: 35°C DB

Heating Indoor Temp: 20°C DBOutdoor Temp: 7°C DB /6°C WB

Running current is at rated conditions (AS3823) and does not include compressor start-up or variations in power supply and load conditions.

AUSTRALIA’S FAVOURITE A IRTM

Products in this brochure contain R410A, R407C or R22 refrigerant. Please refer to specifications before installation & servicing this product.

Only persons and/or companies qualified and experienced in theinstallation, service and repair of refrigerant products should be permittedto do so. The purchaser must ensure that the person and/or companywho is to install, service or repair this air conditioner has qualificationsand experience in refrigerant products.

Suitable access for warranty & service is required.

For future improvement, specifications, designs of product and availabilityare subject to change without notice. Please check with your dealer.

N807

All products specified in this brochure comply with the Australian Communications Authority’s (ACA) requirements for Electromagnetic Compatibility (EMC).

QAS is Accredited by the Joint Accreditation System of Australia and New Zealand,Acc No. S1250992AS

ISO 9002Certified number: JQA-2005

ISO 14001Certified number: EC98J1137

Hamamatsu Fujitsu General Ltd.