automated maze system development group 9 tanvir haque sidd murthy samar shah advisors: dr. herbert...

29
Automated Maze System De velopment Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Upload: chester-williams

Post on 17-Jan-2016

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Automated Maze System Development

Group 9Tanvir HaqueSidd MurthySamar Shah

Advisors: Dr. Herbert Y. Meltzer, PsychiatryDr. Paul King, Biomedical Engineering

Page 2: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Introduction

Microdialysis Method of

measuring physiological activity during task

Dr. Meltzer’s Lab uses it to study brain activity during memory tasks

Page 3: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Experimental Setup

Rat hooked up to Microdialysis

Rat placed in Maze, performs memory tasks

Sample collected during maze run

Sample Analyzed for content

Page 4: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Problems

Dialysis tubes’ entanglement

Rat’s recognition of overhead device psychological

repercussions Manual guiding of

tubes cumbersome for researcher

Page 5: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Constraints

Maze Dimensions Rat Size Rat Speed Rat Cognition Tube Length Dialysis Weight

Depth: 18”

Page 6: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Primary Objective

To develop a fully independent research module that facilitates the study of memory

Page 7: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

System Description

Acquire Mouse Position

Determine Change

in Position

Translate Dialysis Machine

Page 8: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Position Acquisition

Method Pros Cons

Camera High Resolution Real-Time feedback Software intensive

Mounting Issues Processing Limitations$1,355

Sensor Manageable data Less processing$1,160

Low resolution Center of maze difficult to map

Page 9: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Image Processing

Acquire Image Calibrate the Image

Convert the 32 bit image to an 8 bit image

Filter Image 1: Remove Border Objects

Filter Image 2: Remove Small Objects

Pattern Match to a Specified Image

Determine the pixel at the center of the pattern

Translate pixel value into physical coordinates

Output Physical coordinates in array form

Page 10: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

LabVIEW Software Code

Page 11: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Image Processing

Unprocessed Image Processed Image

Page 12: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

LabVIEW Screen Shot

Page 13: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Choosing a Microprocessor

Motorola 68HC11E One 8-bit input Low cost On board A to D

converter $200

NI PCI-7342 Four 8-bit inputs More processing

capabilities Software

Compatibility with LabView

$895

Page 14: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Processing the Information

Continually Given one set of coordinates (X,Y)

Compares the coordinates of (Xn-1,Yn-1) to (Xn,Yn), computes the difference, and rounds the significant digits

Converts the difference into specified timed waveform for the driver

Driver amplifies signal and controls motor speeds

Page 15: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Drive System

Lead-screw Device Easy to build Inefficient $1,576.72

Pulley/Belt System Complicated System Efficient $6,000

Page 16: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

The Lead-Screw Device

• Motor Driven

• Rotational Energy converted to Linear Energy

Page 17: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Device Apparatus

Page 18: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Device Apparatus

• Driven by dual motor system

• Translation responds to mouse movements

• Open Loop Feedback

Page 19: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Choosing a Motor

Design Considerations: Speed of Mouse: 2 ft/s Torque

Torque needed to drive apparatus Torque needed to provide acceleration

Stepper Motor or DC Motor?

Page 20: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Speed

Lead (in/rev) RPM

.125 11520

.25 5760

.5 2880

RPM = 25.5 in/s / Lead*60 s/min

Target RPM Range 3000 -12000

Page 21: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Torque

Driving Torque Driving Torque

Acceleration

Driving Torque

2 ft/s I

L = 2.37 lbsP = .5 in/revef= .4 (for ACME)

Tf = 53 mNm

Posi

tion

Time

25 in

-25 in

I = 0.001207 lb-in-s2

α = 265 rad/s2

T = 36 mNm

Worst Case Scenario

Page 22: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Stepper or DC?

Stepper Torque < 3.53 Nm RPM < 2000

DC High Torque High RPM

Page 23: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

DC Motor

3000 RPM (using 0.5 lead)

87 mNm Torque Powered by Driver Monitored by

external Optical Encoder

Page 24: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Flow Chart

Image Calculate Δ(x,y)

Micro-Processor

DriverMotor Translation

Image Calculate Δ(x,y)

Micro-Processor

DriverMotor Translation

Page 25: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Budget

Support Scaffolding $99.70

Mechanical Arm (including driver electronics)

$1576.72

Microcontroller $895.00

Labview/Imaging Software $1,355.00

Grand Total $3926.42

Page 26: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Departmental Reconsiderations

Budget limitations caused the psychiatry department to reconsider the value of their experimental setup.

Thus, our design, though it was considered valuable by the department, was not approved.

Page 27: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Contingency plan

Develop a model which represents fundamental principles of design

Image acquisition system demonstration – LabVIEW software

Mechanical arm system demonstration – Erector set

Page 28: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Overall Status

Developing Theoretical Model Next step: Final Report and Poster Board

Month/Tasks January February March April

Breakdown of parts needed        

Researched parts and obtained quotes        

Offer proposal for parts        

Develop theoretical model        

Build theoretical model        

Work on Poster Board        

Work on Final Report        

Page 29: Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering

Conclusion

Though no tangible design will be developed, a better understanding of image acquisition systems, micro-processing and linear actuators was obtained

With the development of the theoretical model, the perceived design was realized and used for its educational purposes