automatic tintometer - · pdf filepfxi 995/p lovibond rybn, gardner, saybolt colour, astm...

17
Model Description PFXi 995 Lovibond RYBN, AOCS-Tintometer, Gardner, Pt-Co/Hazen/APHA, FAC, beta, Carotene, Iodine, Hunter Lab, Kreis, Chlorophyll A & B, CIE Values, Spectral Data PFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, Pt-Co/Hazen/APHA, CIE Values, Spectral Data, IP Units PFXi 950/P Saybolt Colour, ASTM Colour, Pt-Co/Hazen/APHA, IP Units, CIE Values, Spectral Data PFXi880/IP7 Lovibond RYBN, CIE Values, Spectral Data PFXi880/L Lovibond RYBN, CIE Values, Spectral Data PFXi880/AT AOCS-Tintometer Colour, CIE Values, Spectral Data PFXi880/P Saybolt Colour, ASTM Colour, CIE Values, Spectral Data PFXi880/S Lovibond RYBN, ICUMSA Colour (420, 560, 720nm) CIE Values, Spectral Data All above models are available with Heater option ORDERING INFORMATION Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected] 41 Automatic Tintometer FEATURES RCMSi Remote Calibration & Maintenance Service via internet, USB & LAN Interface Extensive yet flexible choice of standard colour scales Optional heated sample chamber for maintaining samples at high temp. Accommodates cells of up to 6" (153 mm) in length Remote upgrade facility for adding scales once in service Allows calculation and description of off-hue status Gives closest match to stored references Generates a customised colour scale from reference samples Robust steel construction with excellent chemical resistance Easy maintenance with removable sample chamber Supplied with colour control software for data analysis Output conforming to GLP including date, time, sample & user ID The PFXi series of spectrophotometric colorimeters introduces a unique concept in liquid colour control: RCMSi technology (Remote Calibration & Maintenance Service via internet). Users can benefit from the capability for remote calibration and servicing via the internet - eliminating any costs and time delays associated with servicing and guaranteeing compliance with standards. The PFXi range is supplied with a full range of colour scales for specific markets including, but not limited to, Petroleum, Edible Oils, Pharmaceuticals, Brewing and Honey. Users can upgrade scales remotely at any time. The PFXi-880, -950 & -995 series are available with an optional integrated heater unit. SPECIFICATION Measuring principle 16 interference filters Spectral response 420 – 710 nm • Bandwidth 10 nm • Chromaticity +/– 0.0002 • ?E 0.2 Measurement time Less than 30 seconds Baseline calibration Single key press; fully automated Light source 5 Volt, 10 Watt Tungsten Halogen • Illuminants CIE Illuminant A, B, C, D65 Observer 2°, 10° Lovibond Tintometer Path length 0.1 – 153 mm (0.004" – 6") Interface USB, LAN, RS232 Data storage 100,000+ Measurements Input voltage Universal (90 – 214 Vac), via external power supply Compliance CE, RoHS, WEEE Display 240 x 128, back-lit graphic display, (white on blue) Keypad 23 key tactile membrane keypad; washable polyester with audible feedback Instrument Fabricated steel with tough, housing textured paint finish PFXi-880, 950, 995 Series

Upload: ngocong

Post on 09-Mar-2018

291 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Model Description

PFXi 995 Lovibond RYBN, AOCS-Tintometer, Gardner, Pt-Co/Hazen/APHA, FAC, beta, Carotene, Iodine,

Hunter Lab, Kreis, Chlorophyll A & B, CIE Values, Spectral Data

PFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, Pt-Co/Hazen/APHA, CIE Values, Spectral

Data, IP Units

PFXi 950/P Saybolt Colour, ASTM Colour, Pt-Co/Hazen/APHA, IP Units, CIE Values, Spectral Data

PFXi880/IP7 Lovibond RYBN, CIE Values, Spectral Data

PFXi880/L Lovibond RYBN, CIE Values, Spectral Data

PFXi880/AT AOCS-Tintometer Colour, CIE Values, Spectral Data

PFXi880/P Saybolt Colour, ASTM Colour, CIE Values, Spectral Data

PFXi880/S Lovibond RYBN, ICUMSA Colour (420, 560, 720nm) CIE Values, Spectral Data

All above models are available with Heater option

ORDERING INFORMATION

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected] 41

Automatic Tintometer

FEATURES

• RCMSi Remote Calibration & Maintenance Service via internet, USB & LAN Interface

• Extensive yet flexible choice of standard colour scales

• Optional heated sample chamber for maintaining samples at high temp.

• Accommodates cells of up to 6" (153 mm) in length

• Remote upgrade facility for adding scales once in service

• Allows calculation and description of off-hue status

• Gives closest match to stored references

• Generates a customised colour scale from reference samples

• Robust steel construction with excellent chemical resistance

• Easy maintenance with removable sample chamber

• Supplied with colour control software for data analysis

• Output conforming to GLP including date, time, sample & user ID

The PFXi series of spectrophotometric colorimeters introduces a unique concept in liquid

colour control: RCMSi technology (Remote Calibration & Maintenance Service via internet).

Users can benefit from the capability for remote calibration and servicing via the internet -

eliminating any costs and time delays associated with servicing and guaranteeing compliance

with standards.

The PFXi range is supplied with a full range of colour scales for

specific markets including, but not

limited to, Petroleum,

Edible Oils,

Pharmaceuticals, Brewing

and Honey. Users can

upgrade scales remotely at

any time.

The PFXi-880, -950 & -995

series are available with an

optional integrated heater

unit.

SPECIFICATION

• Measuring principle 16 interference filters

• Spectral response 420 – 710 nm

• Bandwidth 10 nm

• Chromaticity +/– 0.0002

• ?E 0.2

• Measurement time Less than 30 seconds

• Baseline calibration Single key press; fully

automated

• Light source 5 Volt, 10 Watt Tungsten

Halogen

• Illuminants CIE Illuminant A, B, C, D65

• Observer 2°, 10°

®

Lo

vib

on

dT

into

me

ter

• Path length 0.1 – 153 mm (0.004" – 6")

• Interface USB, LAN, RS232

• Data storage 100,000+ Measurements

• Input voltage Universal (90 – 214 Vac), via

external power supply

• Compliance CE, RoHS, WEEE

• Display 240 x 128, back-lit graphic display,

(white on blue)

• Keypad 23 key tactile membrane keypad;

washable polyester with audible

feedback

• Instrument Fabricated steel with tough,

housing textured paint finish

PFXi-880,950, 995

Series

Page 2: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Model Description

PFXi-195/1 Pt-Co/Hazen/APHA, Gardner, Iodine, CIE Values, Spectral Data

PFXi-195/2 Saybolt, ASTM Colour, Pt-Co/Hazen/APHA, CIE Values, Spectral Data

PFXi-195/3 FAC, Gardner, CIE Values, Spectral Data

PFXi-195/4 EBC (CIE & 430nm), ASBC (CIE & 430 nm) Series 52(Brown), CIE Values, Spectral Data

PFXi195/5 Pharmacopoeia, (European & US), Pt-Co/Hazen/APHA, CIE Values, Spectral Data

PFXi195/6 Klett Colour (blue filter KS-42), Pt-Co/Hazen/APHA, Hess-Ives Units, CIE Values, Spectral Data

PFXi195/7 ICUMSA Colour (420, 560, 710 nm) Honey Colour, Series 52(Brown), CIE Values, Spectral Data

PFXi-195/8 ADMi (spectral & tristimulus filter methods) Pt-Co/Hazen/APHA, CIE Values, spectral data

PFXi195/9 CIE Values (standard selection), L*C*h colour space, Hunter Lab colour space, Spectral Data

ORDERING INFORMATION

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected]

SPECIFICATION

• Measuring principle 9 interference filters

• Spectral response 420 – 710 nm

• Bandwidth 10 nm

• Repeatability On measurements of de-

ionised water

• Chromaticity (x y) +/– 0.0004

• ÄE 0.4

• Measurement time Less than 30 seconds

• Baseline calibration Single key press; fully

automated

• Light source 5 Volt, 10 Watt Tungsten

Halogen

• Illuminants CIE Illuminant A, B, C, D65

®

Lo

vib

on

dT

into

me

ter

• Observer 2°, 10°

• Path length 0.1 – 50 mm

• Interfaces USB, LAN, RS232

• Data storage 100,000+ Measurements

• Input voltage Universal (90 – 240 Vac), via external

power supply

• Compliance CE, RoHS, WEEE

• Display 240 x 128, back-lit graphic display,

(white on blue)

• Keypad 23 key tactile membrane keypad;

washable polyester with audible

feedback

• Instrument Fabricated steel with tough,

housing textured paint finish

The PFXi series of spectrophotometric colorimeters introduces a unique concept in liquid colour

control: RCMSi technology (Remote Calibration & Maintenance Service via internet).

The PFXi range is supplied with a full range of colour scales for specific markets including, but

not limited to, Petroleum, Edible Oils, Pharmaceuticals, Brewing and Honey. Users can upgrade

scales remotely at any time.

Every PFXi is supplied with colour control software for data analysis (LAN & USB cable provided).

Optical glass cells, a certified glass calibration filter, a spare lamp and user instructions included.

Electronic Tintometer

PFXi-195Series

FEATURES

• RCMSi Remote Calibration &

Maintenance Service via

internet

• USB & LAN Interface

• Large clear LCD screen

for ease of use and

ability to display

graphs and data in

a wide variety of

languages

• Extensive yet flexible choice of

standard colour scales

• Remote upgrade facility for adding scales once in service

• Allows calculation and description of off-hue status

• Gives closest match to stored references

• Generates a customised colour scale from reference samples

• Robust steel construction with excellent chemical resistance

• Easy maintenance with removable sample chamber

• Supplied with colour control software for data analysis

• Output conforming to GLP including date, time, sample & user ID

• Accommodates a range of sample cells and tubes

Page 3: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Model Description

Model F Standard model for applications including fats and fatty oils, bleached lac, liquid

chemicals and pharmaceuticals.

Model F (BS 684) Version for measuring animal and vegetable fats and oils according to BS 684 Section

1.14, ISO 15305 and AOCS Method Cc 13e-92. Racks are fitted with colourless glass

compensating slides in the sample field.

ORDERING INFORMATION

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected] 43

Model FSeries

The Model F is a visual colorimeter designed to optimise the use of Lovibond® glass filters in order

to express colour in terms of Lovibond® Red, Yellow, Blue and Neutral.

It is arranged with two adjacent fields of view, seen through the viewing tube, so that the product in

the sample field and a white reflective surface in the comparison field are observed side by side,

suitably illuminated.

The Lovibond® glasses are introduced into the comparison field by a simple system of sliding racks,

allowing the user to compare the colour of light which is either transmitted through, or reflected

from, the sample.

A series of neutral glasses in racks is also supplied; these can be introduced into the sample field to

'dull' the colour of products which are too bright to obtain a good colour match using Lovibond®

Red, Yellow or Blue glasses. The racks allow a visual colour match to be found from the light from

the sample and its colour can then be expressed in Lovibond® units.

SPECIFICATION

• Measuring principle Visual, in terms of Lovibond® units

• Modes Transmittance, reflectance

• Range 0.1 - 7 Red, Yellow; 0.1 - 4 Blue; 0.1 - 3.9 Neutral

• Resolution 0.1 Lovibond® unit

• Optical system 11 glass-filled nylon racks containing a graduated range of Lovibond® colour standards

• Viewing system Fully adjustable, prismatic with integral blue filter for light standardisation

• Light source 2 x 12 Volt, 10 Watt tungsten halogen lamp

• Illuminant Approximates to daylight

• Path length Up to 153 mm (6”)

• Power pack Universal, via external power supply

• Approvals CE

• Instrument housing Fabricated sheet steel with a tough, textured paint finish

FEATURES

• Glass colour standards housed in durable racks

• External, low-voltage regulated power supply

• Prismatic optical system provides improved colour matching

• Balanced field of view

• Diffused tungsten-halogen light source

• Replaceable sample chamber liner

Lovibond Tintometer

®

Lo

vib

on

dT

into

me

ter

Page 4: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Colour Scale Nominal Certified Value Order Code Accreditation Standard

AOCS-Tintometer 0.3R 2.0 Y (5¼") 134240 ISO 9001

Colour 1.0R 9.0Y (5¼") 134250 ISO 9001

(AOCS Cc 13j-97, 1.2R 12.0Y (5¼") 134260 ISO 9001

Cc 13b-45) 2.2R 22.0Y (5¼") 134270 ISO 9001

3.6R 28.0Y (5¼") 134280 ISO 9001

ASTM Color 0.4 (<0.5) 134290 UKAS

(ASTM D6045, 1 134000 UKAS

D1500) 3 134010 UKAS

5 134020 UKAS

Gardner Colour 2 134200 UKAS

(ASTM D1544, 5 134210 UKAS

D6166) 8 134220 UKAS

Lovibond 0.4R 1.9Y 0.1N (5¼") 134080 ISO 9001

RYBN Colour 1.0R 4.3Y 0.1N (5¼") 134090 ISO 9001

(AOCS Cc 13j-97) 1.4R 7.3Y 0.2N (5¼") 134100 ISO 9001

1.6R 11.0Y 0.1N (5¼") 134110 ISO 9001

1.8R 14.0Y 0.3N (5¼") 134120 ISO 9001

2.5R 24.0Y 0.5N (5¼") 134130 ISO 9001

3.3R 33.0Y 0.3N (5¼") 134230 ISO 9001

Platinum-Cobalt 5 mg Pt/l 134140 ISO 9001

Colour 10 mg Pt/l 134150 ISO 9001

(ASTM D1209) 15 mg Pt/l 134160 ISO 9001

30 mg Pt/l 134170 ISO 9001

50 mg Pt/l 134180 ISO 9001

100 mg Pt/l 134190 ISO 9001

500 mg Pt/l 462803 UKAS

Saybolt Colour -10 134040 UKAS

(ASTM D6045, 0 134050 UKAS

D1500) +12 134060 UKAS

+25 134070 UKAS

ORDERING INFORMATION

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected]

®

Lo

vib

on

dT

into

me

ter

W600 Optical Glass Cells for Lovibond Tintometers

10 mm 60 59 60 W600/OG/10

25 mm 60 59 90 W600/OG/25

33 mm 60 60 10 W600/OG/33

40 mm 60 60 20 W600/OG/40

50 mm 60 62 00 W600/OG/50

100 mm 60 60 30 W600/OG/10011/16" 60 60 40 W600/OG/ / "16

1/4" 60 60 60 W600/OG/¼"

1/2" 60 60 70 W600/OG/½"

1" 60 60 80 W600/OG/1"

2" 60 60 90 W600/OG/2"

51/4" 60 61 30 W600/OG/5¼"

6” 60 61 50 W600/OG/6”

Path Length Order Code Cell Type

Cells for PFX995/950/880/195 Series, Tintometer Model F The Cells are 21mm width, 40 mm height and are supplied without lids.

Lovibond Certified Colour Reference Materials (500 ml) Certified

• Ideal for routine calibration of colour measuring instruments & verification of test data

• Ensure good inter-laboratory and inter-instrument correlation

• Applications in statistical quality control (SQC) and statistical process control (SPC)

• High stability standards with a guaranteed 12-month shelf-life

• Full traceability to internationally recognised standards

• All classified as non-hazardous according to EU directives

• Each bottle supplied with full certification including MSDS

The values indicated are typical nominal values; individual values may vary but these

are always specified on the certificate of calibration supplied with each standard:

We supply precision fused cells in a range of dimensions and path lengths, made from optical glass to the highest standards at our own factory. For instruments equipped with a heater unit and whenever cells are subjected to thermal shock, it is recommended that borosilicate cells be used.

Page 5: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Model Description

Lovibond Comparator & Nessleriser Instruments

14 20 00 Comparator 2000+

— DB 424-13.5mm, 10ml, Plastic Comparator Cells each

17 10 10 Daylight 2000 Comparator

17 10 20 Daylight 2000 Nessleriser

17 21 50 Nessleriser 2150 with stand

17 22 50 Nessleriser 2250 with stand

17 20 30 Nessleriser 2150 with Daylight 2000

17 20 40 Nessleriser 2250 with Daylight 2000

35 30 60 AF 306 Pair of Nessler Cylinders 50ml 113mm (BS 612)

35 30 80 AF 306/P Pair of Nessler Cylinders 50ml 113mm with glass anti-meniscus plungers

35 42 00 DB 420 Pair of Nessler Cylinders 250 mm with glass anti-meniscus plungers

35 31 50 AF 315 Special Nessler tube pair (determination of oxygen with disc NOE)

Colour Disc for Colour Comparison

284170 NSH, Hazen Scale Disc, 10 - 90

284120 NSB, Hazen Scale Disc, 70 - 250

284130 NSX, Hazen Scale Disc, 50 - 300

284150 CAA, Hazen Scale Disc, 0 - 30

284160 CAB, Hazen Scale Disc, 30 - 70

243030 4/30AS, Gardner Scale Disc, 1 - 9

243040 4/30BS, Gardner Scale Disc, 10 - 18

Pt-Co/Hazen/APHA Colour Kit (Option 1)

AF 329 Pt-Co/Hazen/APHA Colour, 0-250mg Pt/l, Nessleriser

Nessleriser 2150 with Daylight 2000 Lighting Unit and Nessler cylinders, Nessleriser 2250 upgrade with

Nessler cylinders, Discs CAA range 0-30mg Pt/l, Discs CAB range 30-70mg Pt/l, Discs NSB range 70-

250mg Pt/l

Pt-Co/Hazen/APHA Colour Kit (Option 2)

AF 325 Pt-Co/Hazen/APHA Colour, 10-250mg Pt/l, Nessleriser

Nessleriser 2150 with Daylight 2000 Lighting Unit and Nessler cylinders, Discs NSH range 10-90mg Pt/l,

Discs NSB range 70-250mg Pt/l

Pt-Co/Hazen/APHA Colour Kit (Option 3)

AF 328 Pt-Co/Hazen/APHA Colour Low Range, 0-70mg Pt/l, Nessleriser

Nessleriser 2250 with Daylight 2000 Lighting Unit and Nessler cylinders, Discs CAA range 0-30mg Pt/l,

Discs CAB range 30-70mg Pt/l

Gardner Colour Scale Kit

AF 334 Gardner Colour, 1 - 18 units, Comparator

Lovibond Comparator 2000+ with Daylight 2000 Lighting Unit, W680/OG/10 mm Cell, Disc 4/30 AS

range 1 - 9 units & Disc 4/30 BS range 10 - 18 units

Lubricating Petroleum Oil Comparator (Option 1)

AF509/C ASTM Colour Ltd. Range ASTM D1500, 1 - 5 units, Comparator

Comparator 2000+ with W680/OG/33mm Cell and Disc 4/81 1.0-5.0 units

Lubricating Petroleum Oil Comparator (Option 2)

AF 650 ASTM Colour, ASTM D1500, 0.5 -8 units, Comparator

Comparator 3000 with AF 763 Tube and Disc 1 0.5-7.5 units and Disc 2 1.0-8.0 units

EBC Colour Scale (for Breweries)

AF 330 EBC Colour European Brewery Convention, 2 - 27 units, Comparator

Comparator 2000+ with Daylight 2000 Lighting Unit, W680/OG/25 mm Cell with Disc 4/14A 2-6 unit,

Disc 4/14B 6-10 unit, Disc 4/14C 10-18 unit and Disc4/14D 19-27 unit

ORDERING INFORMATION

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected] 45

®

Lo

vib

on

dT

into

me

ter

Color Comparator

Color Comparator

Lovibond® Comparator System 2000+

A flexible, modular system for Visual Colour Grading

Using a suitable Comparator instrument, the sample

is visually matched against calibrated, colour stable

glass standards in test discs. The Comparator 2000+

is a short path length instrument (up to 40 mm) for

visually matching samples with relatively dark

colours. Nessleriser systems are longer path length

instruments for matching a column of sample in a

glass cylinder of appropriate path length.

Lovibond® Gardner Comparator 3000

A single scale, 3-fi eld instrument for visual colour grading by direct comparison between the sample and Lovibond® glass

colour standards housed in a pair of discs. The advantage of a 3-section field of view is that the sample and two consecutive

glasses on the colour scale are viewed simultaneously, making it easier to achieve the optimum colour match.

Page 6: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Model Description

400300 RT300:0°/45°

400400 RT400:diffuse/8° sphere

400500 Rt500:diffuse/8° sphere

400610 RT Colour Software (for RT300, RT500)

400620 Benchtop Stand

400630 Liquid Cell Holder (recommended for use with benchtop stand)

400640 Powder Cell Holder

400660 V-block Sample Holder

400680 Pellet Holder

ORDERING INFORMATION

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected]

®

Lo

vib

on

dT

into

me

ter

Reflactance Portable Spectrophotometer

FEATURES

• Lightweight, compact, portable instruments

• Diffuse/8° sphere or 0º/45º optical geometry

• Large, easy-to-read graphical LCD display

• Opacity and colour strength measurement

• Flip-back target shoe for flexible use

• Rugged construction

• Rechargeable battery for remote use

SPECIFICATION

• Measuring geometry RT300: 0°/ 45°; RT400 & 500: diffuse/8° sphere

• Spectral response 400 - 700 nm

• Bandwidth 10 nm measured; 10 nm output

• Repeatability RT300 & 400: rE=ab* = 0.1 on white reference

RT500: rE=ab* = 0.05 on white reference

• Measurement range 0 - 200% reflectance

• Measurement area RT300: 7 mm; RT400 & RT500: 8 mm

• Measurement time Approximately 2 seconds

• Light Source Gas-filled tungsten lamp

• Illuminant C, D50, D65, D75, A, F2, F7, F11 & F12

• Observer 2°, 10°

• Interface RT400: RS232; RT300 & 500: interface to RT Colour Software via patented bi-

directional RS232, 300 - 57600 baud

• Data Storage 1024 standards with tolerances, 2000 samples

• Display 128 x 256 pixel in-built graphic LCD

• Lamp Life Approx. 500,000 measurements

• Power Supply Removable (Ni-metal hydride) battery

• AC adapter requirements 90 - 130VAC or 100 - 240VAC, 50 - 60Hz, 15W max

• Charge time Approx. 4 hours - 100% capacity

• Measurements per charge 1000 measurements within 8-hour period

• Sphere Spectralon® (a durable, highly reflective material that prevents premature

(RT400 & RT500) degradation)

RTSeries

The RT 250, RT 300, RT 400 and RT 500 are versatile, portable spectrophotometers in a choice

of diffuse/8° sphere or 0°/45° optical geometry that are designed to give fast, precise and

accurate colour measurement information on a range of products. They provide absolute and

difference measurements in various colorimetric systems.

The RT 300 and RT 500 can be combined with the OnColorTM software package allowing

measurement data to be downloaded, analysed in detail and stored indefinitely on a PC.

The RT 250, RT 300, RT 400 and RT 500 can also be combined with a wide range of accessories

allowing the repeatable measurement of liquids, gels, powders and other materials.

Page 7: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Model Description

401100 Lovibond® LC 100 Spectrophotometer

401120 Integrated Package : LC 100 & SV 100 Kit

132750 Replacement Cells (10mm, Pk 100)

ORDERING INFORMATION

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected] 47

LC 100 SV 100

®

Lo

vib

on

dT

into

me

ter

FEATURES

• Hand-Held Imaging Spectrocolorimeter

• Unique housing stand to protect sample from ambient light

• Enables measurement of food, powders, cosmetics & pastes

• Versatile Communication of Colour Measurement

• Single, Simple, Reliable, Integrated Tool - no need to connect to PC

• Readings and Comparison Charts within Seconds

• Information on Colour and Surface Texture Effects

• Conformance Reports in PDF and Excel Formats

• Precise Image Sampling with 9 Band Accuracy

SPECIFICATION

• Measuring Geometrics 45/0 Image Capture

• Light Source Independent tri-directional 25 LED (8* visible wavelengths; 1* UV)

• Illuminant/Observer D65&A(10)

• Standards/Sample Storage 20/350

• Measurement Time 1.8 seconds

• Measuring Area 4 & 8mm

• Short Term Repeatability Typical 0.10 ÄE 94 on white (D65/10)

• Display 4.5cm Colour TFT

• Data Interface USB (Mass Storage Device)

• Operating Temperature 0° to 40°C (50° to 104°F)

• Storage Temperature -20° to 60°C (-4° to 140°F)

• Humidity Range 20-80% RH (non-condensing)

• Usage Indoor Use Only

• Altitude 2000m

• Polution Degree 2

• Transient Overvoltage Category II

The Lovibond® LC 100 and SV 100 integrated package provides a unique solution to users looking

to measure food, powders, cosmetics and pastes.

The SV 100 holder supports the LC 100 at an ergonomic viewing angle to enable the

measurements in Lovibond® optical cells. A secure cap is provided to cover the sample, protecting

it from any excessive ambient light, enabling quick yet accurate readings.

The units are provided in a purpose-designed case containing all the accessories required for

accurate colour measurement expected of the Lovibond® brand.

The Lovibond® LC 100 enables setting and maintaining colour standards throughout the

manufacturing process. It is a lightweight tool that is easy to handle and ready to use. In just over a

second, it not only provides a reading of the sample but also a report telling how close the colour is

to a measured standard. Together with the Lovibond® SV 100, it is the ideal solution for the colour

measurement of food, powder, cosmetics, pastes and pharmaceuticals.

The LC 100 automatically creates conformance reports in either PDF or Excel formats for each

stored sample against each standard. These can easily be shared with a PC or directly to a

compatible printer (via USB mass storage mode).

Reflactance Hand-Held Spectrophotometer

Page 8: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected]

COD System

ORDERING INFORMATION

Model Description

2892502 COD-Setup COD complete with photometer, 2 sets of tube tests 25 vials 0-150 mg/l,

and 0-1500 mg/l and Reactor

COD-reactor

COD Reagent Vials

242 07 20 0 - 150 mg/l O2

242 07 21 0 - 1500 mg/l O 2

242 07 22 0 - 15000 mg/l O 2

COD System

Chemical oxygen demand (COD) is an important parameter for the assessment of municipal and

industrial waste water. COD is used to analyse the organic component of water by determining

the amount of oxygen required to oxidise these components.

During COD determination, the sample is heated and strong oxidising agents added to convert

the organic matter present. In combination with high temperatures, the oxidising agents ensure

complete oxidation of the organic components in the water. The COD value therefore indicates the total level of

oxidised organic components in the water sample.®

CHECKIT COD

The COD test setup allows highly sensitive and precise water testing with minimum effort. It measures the

amount of oxygen required for oxidation of the water components by photometric means.

A known sample volume is added to a COD vial test, which is heated in the reactor and then analysed in the

COD vario photometer.

COD vario photometer

With a measuring range from 0 to 15,000 mg/l O , the COD vario photometer is suitable for waste water 2

testing.

Two LEDs light sources with long-term stability (n1 = 605 nm; n2 = 430 nm), a waterproof sample chamber, a

large digital display, and the user-friendly keypad ensure maximum operating reliability and convenience.

COD vario tube tests

The COD tube tests are available for the measuring ranges 0-150 mg/l O , 0-1500 mg/l O and 0-15000 mg/l O . 2 2 2

Their chemical properties and a 16 mm tube diameter is suitable also for use with Hach photometers.

®

Lo

vib

on

dT

into

me

ter

Page 9: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected] 97

BOD System

ORDERING INFORMATION

Model Description

02444406 BOD OxiDirect System with 6 Sensors

02444410 BOD OxiDirect System with 12 Sensors

418328 BOD CM Test Tablets Box/8 Tablets

41 86 45 BOD Sample Bottles, Brown Glass, 500 ml (without sensor head)

02444430 Sensor Head

41 86 57 Overflow Flask, 157 ml

41 86 60 Overflow Flask, 428 ml

2 41 86 34 Potassium Hydroxide Solution, 45 %, 50 ml

2 41 86 42 Nitrification inhibitor (N-ATH), 50 ml

®

Lo

vib

on

dT

into

me

ter

BOD System

Accurate Direct, Easy to use, Flexible, (n=1-28 days)

Environmentally-friendly

Biochemical Oxygen Demand (BOD)

BOD – biochemical oxygen demand – is an expression for the quantity of oxygen

required for biological degradation of organic matter in a waste water sample. BOD

measurement is therefore used as a basis for the detection of biologically degradable

organic matter in water. The difference between BOD and chemical oxygen demand

(COD) is that the COD additionally registers biologically non-degradable organic matter.

BOD measurement is therefore an important measurement of

the effects of domestic and industrial waste water on sewage

plants and outflow points. Manometric, respirometric BOD measurement using

® the Lovibond OxiDirect BOD meter® ®

The Lovibond sensor system OxiDirect is a 6 sample

system that allows precise measurement of BOD

based on the manometric principle. Manometric

respirometers relate oxygen uptake to the change

in pressure caused by oxygen consumption while

maintaining a constant volume. Thanks to the

modern integral pressure sensors, it is no longer

necessary to use mercury for pressure measurement.

®

Incubator with glass door

• Backlit Display

• 2 °C to 40 °C

• adjustable in steps of 0.1 °C

• 20 °C BOD determination

• 4 °C storage of waste water samples

• 25 °C Enzyme activity (TTC test)

• 37 °C Colony count

• BOD-Measurement

• Microbiological Research

• Food industry

• Dairies

• Laboratories

• Research Centres

• Universities

Highlights

Applications

Incubators-Thermostatically Controlled

BOD Measurement System

ORDERING INFORMATION

Model Capacity Type

ET 619 140 ltr. 3 racks

ET 627 195 ltr. 4 racks

ET 637 280 ltr. 5 racks

ET 651 395 ltr. 5 racks

Incubators

Page 10: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected]

TurbiDirect

TurbiCheck

ORDERING INFORMATION

ORDERING INFORMATION

Model Description

194000 Turbidity Meter

Accessories

19 41 50 Set Turbidity Standards T-CAL (<0.1, 20, 200, 800 NTU)

Model Description

26 60 20 Lovibond® TurbiCheck turbidity meter as described above, complete with 4 turbidity

standards < 0.1, 20, 200, 800 NTU, battery and test vial, in case, ready to use

Accessories

19 41 50 < 0.1, 20, 200, 800 NTU Turbidity Standard, 4/set

®

Lo

vib

on

dT

into

me

ter

Turbidity Meter

TurbiDirect with infra-red light source

High-precision instrument for laboratory and mobile use

Turbidity is measured according to EN ISO 7027 by nephelometric means (90° scattered light). The

infra-red light-source permits measurement of coloured and colour-free samples.

The automatic measurement range detection facility (Autorange) enables direct turbidity

measurement from 0.01 to 1100 NTU with an accuracy of ± 2% up to 500 NTU and ± 3% thereafter.

A large graphic display, a choice of several different languages and user-friendly operating

instructions make the device extremely easy to use.

The compact Lovibond® infrared turbidity meter TurbiCheck is designed to allow fast, precise on-

site testing. The unit measures the scattered light at an angle of 90°, as stipulated in EN ISO 7027.

The wide measuring range from 0.01 - 1100 TE/F = NTU = FNU makes the instrument suitable for

various applications, ranging from drinking water to waste water.

As infrared light is used for measurement purposes, the unit can be used to test both coloured and

colourless liquids.

The standards required for calibration of the unit are also supplied. A second adjustment mode

allows alternative adjustment with user-defined turbidity standards.

Highlights

• Meets EN ISO 7027

• Automatic overall range adjustment

with Standards-Set-T-Cal

• High accuracy

• For laboratory and mobile use

• RS232 interface

• Storage for up to 1000 data-sets

• Real-time clock

• Waterproof sample chamber and

housing

Highlights

• Range 0.01 - 1100 NTU

• Measurement with infrared light

at an angle of 90°

• Measurement of coloured liquids

• Easy handling

• 600 tests without battery change

TurbiCheck with infra-red light source (EN ISO 7027)

Page 11: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected] 99

SensoDirect200

ORDERING INFORMATION

Model Description

72 22 20 SensoDirect Con200 Hand Held Meters

72 22 25 SensoDirect Conductivity Cell, 4-Pole Technology

72 22 50 Calibration Solutions 1413 µS/cm

72 32 20 SensoDirect Oxi200 Hand Held Meters

72 32 01 Oxygen Sensor, 1.5 m cable

72 32 50 Service set Oxygen Sensor 3 interchangeable membrane heads, 100 ml plastic bottle KOH-

solution 3 mol/l

®

Lo

vib

on

dT

into

me

ter

ORDERING INFORMATION

Model Description

724610 SD 300 pH (SET 1), instrument, batteries, pH/temp. plastic-electrode type 230, pH-buffer-set

(pH 4.00/7.00/10.00), in case, manual, guarantee sheet

721230BNC pH/temp.-electrode type 230 plastic/gel/temperature NTC30kOhm (Set 1)

724611 SD 300 pH (SET 2), as SET1, but with pH / temperature plastic-electrode type 225,

temperature sensor Pt 1000, manual, guarantee sheet

721225BNC pH-electrode plastic/gel-type 225

SD300 pH

pH/TDS/DO MetersSensoDirect 200 / 300Lovibond® Hand-Held Meters SensoDirect 200 (IP 67 water proof)

Determination of: Conductivity/TDS /Dissolved Oxygen

The new microprocessor-controlled SensoDirect range of handheld meters from Lovibond

meets the day-to-day demands for sturdy and reliable systems for the measurement of

conductivity/TDS and dissolved oxygen.

The water-tight housing complies with IP67 and is equipped as standard with protective armouring and built-

in electrode holder, ensuring reliable operation even in extreme ambient conditions.

The support can be flipped up to hang the meter on pipes or branches.

A direct, easily understood user interface, outlining the required configuration

options for all three systems, facilitates meter operation both outdoors and in the

laboratory.

The automatic Hold function "freezes" stable measuring data in the

display and indicates the presence of stable and reproducible results.

The internal memory allows storage of 20 data sets to facilitate

subsequent evaluation. The integral automatic switch-off feature,

varying from 1 to 120 minutes, increases the operating life of the

units.

The power consumption of all two units has been reduced to a

minimum. As a result, the 4 x 1.5 V integrated batteries have an

operating life of up to 15000 hours, depending on the unit version.

®

SD300 pH (IP 67 waterproof)

Waterproof Hand-held Meter for pH/Redox/Temperature

• Rugged, water resistant (IP 67) designed for field use

• PC interface for data download (USB / serial or analog)

• Automatic buffer detection for calibration

• Data logger and alarm function (min./max.)

• Good Laboratory Practice (GLP-features)

• Clear, concise result reading: easy-to-read backlit LCD display

• Automatic temperature compensation

• High resolution (0.001 pH / 0.1 mV)

• Drinking Water

• Cooling/Boiler Water

• Waste Water

• Pool Water

• Surface Water

Highlights

Applications

TDS

DO2

Page 12: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected]

SensoDirect150 Series

SensoDirect110 Series

ORDERING INFORMATION

ORDERING INFORMATION

Model Description

72 42 00 SensoDirect 150 set, pH / Con / TDS / Oxi instrument, batteries, pH electrode, temperature

probe, conductivity probe, oxygen sensor, pH buffer set 4,00 / 7,00, electrolyte, membrane

heads, instruction manual, guarantee sheet, in case

72 42 10 SensoDirect 150 set, pH / Con / TDS instrument, batteries, pH electrode, temperature probe,

conductivity probe, pH buffer set 4,00 / 7,00, instruction manual, guarantee sheet, in case

72 42 20 SensoDirect 150 set pH / Oxi instrument, batteries, pH electrode, temperature probe, oxygen

sensor, pH buffer set 4,00 / 7,00, electrolyte, membrane heads, instruction manual, guarantee

sheet, in case

721330 Spare electrode, (approx. 1 m cable), plastic/gel type BNC-plug

721250 pH buffer set 4.00/7.00/10.00 (25°C)

721242 Redox electrode, (approx. 1 m cable), plastic/gel type BNC-plug

722250 Calibration solution 1413 ìS/cm

724460 Spare membrane for oxygen sensor

724470 Spare electrolyte for oxygen sensor

724420 Temperature probe PT1000 (approx. 1.5 m cable)

Model Description

72 13 00 SensoDirect pH 110 complete set, instrument, battery, pH buffer (4.0/7.0) pH plastic electrode

110, carry in case

72 13 30 pH-electrode plastic/gel, type pH110

72 23 00 SensoDirect Con110 complete set, instrument, battery, conductivity sensor, carry in case

72 22 50 Conductivity calibration solutions, 1413 µS/cm, 500ml

72 33 00 SensoDirect Salt 110, battery, sensor, in case

®

Lo

vib

on

dT

into

me

ter

Highlights:

• pH/Redox Conductivity

Dissolved Oxygen etc.

• All in one

• Real time data logger

• Large digital display

• Protective casing

• RS 232 / USB

Applications:

• Drinking water

• Cooling/Boiler Water

• Waste Water

• Pool Water

• Surface Water

• Water Treatment Companies

• Industrial and Governmental Laboratories

pH/TDS/DO MetersSensoDirect 150 / 110

SensoDirect 150 Series Multi Parameter Hand-Held Meter

SensoDirect 110 Series for pH, Conductivity & Salinity

pH 110 - The SensoDirect pH 110 is a high quality, portable, battery operated pH meter with a

measuring range of 0 - 14 pH. The instrument is equipped as standard with protective casing and

built-in electrode holder, ensuring reliable operation even in extreme ambient conditions. The unit

is equipped with an automatic battery check feature. If the low battery indicator appears it is time

to change the battery.

Con110 - The SensoDirect Con110 is a compact and versatile meter that

can be used wherever there is a need to measure conductivity accurately

and quickly. The unit is extremely easy to use and equipped as standard

with a protective casing and built-in electrode holder.

It is equipped with a LC display showing two or three decimal places and

a measuring range either of 0.001 - 1.999 or 0.01 - 19.99 mS/cm.

Salt110 - The portable SensoDirect Salt110 provides fast, accurate

readings and the convenience of a remote probe separately.

The measuring range of this salt tester is 0 to 10 % salt ( % weight ).

The SensoDirect Salt110 includes an automatic temperature

compensation feature. The unit is extremely easy to use and is equipped

as standard with a protective casing and built-in electrode holder.

The SensoDirect 150 combines the features of several hand-held meters. It is designed for

multipurpose operation and measures pH/Redox, dissolved oxygen and conductivity/TDS.

The SensoDirect 150 incorporates an intuitive user interface, large, easy to read display

and is supplied with a sturdy handy case with electrodes, buffer solution and accessories.

Page 13: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected] 101

MD100Photometer

®

Lo

vib

on

dT

into

me

ter

Photometer

MD 100 PhotometerPrecise Water Analysis in High- Quality Design Small • Mobile • Rapid

Designed to meet the latest technical requirements, the MD 200 photometer can be used in

practically every area of water analysis.

The high-precision optics with its top-quality interference filters uses long-term stable LEDs as

light-source. Because there are no moving parts, the entire measurement device requires absolutely no

maintenance. Precise and reproducible analysis results are obtained in a short time. The units impress with

their user-friendliness, ergonomic design, compact dimensions and easy handling.

The tests are conducted using either Lovibond®tablet reagents with long-term stability and a guaranteed

minimum 5 or 10 year shelf life or using liquid reagents.

Precise results using high-quality interference filters

single Parameter

•COD

2 in 1

•Chlorine, pH

•Copper, pH

•Hydrogen peroxide, pH

3 in 1

•Chlorine, pH, Bromine

•Chlorine, pH, Stabilizer

•Chlorine, pH, Alkalinity-M

4 in 1

•Chlorine, pH, Stabilizer, Alkalinity-M

5 in 1

•Chlorine, pH, Stabilizer, Alkalinity-M, Calcium hardness

6 in 1

•Chlorine, Bromine, pH, Stabilizer, Alkalinity-M, Calcium

hardness

MD 200 Photometer

The MD 100 uses high quality interference filters with long-life LEDs as a light source without any

moving parts in a transparency sample chamber. The units supply accurate, reproducible results

very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and

safe handling. The calibration and software-based adjustment options mean that the MD 100 is also suitable

for use as a testing instrument. The tests are conducted using either Lovibond® tablet reagents with long-term

stability and a guaranteed minimum 5 or 10 year shelf life, VARIO powder reagents or using liquid reagents.

Single Parameters• Aluminium• Ammonia• Ammonium• Monochloramine• Chlorine• Chlorine DUO• Chlorine HR • Chlorine dioxide• COD• Copper• Hardness, total• Hazen• Iron• Iron TPTZ

Single Parameters• Fluoride• Manganese LR• Manganese HR• Molybdenum LR • Molybdenum HR• Molybdenum• Monochloramine • Phosphate• Silica• Silica LR• Silica HR• Suspended solids • Urea

MD200Photometer

Highlights• Scroll Memory• Automatic switch-Off• Real-Time-Clock and Date• Calibration Mode• Backlit Display• Storage Function• One Time Zero (OTZ)• Waterproof**as defined in IP 68, 1 hour at 0.1 meter, buoyant

Highlights

• Scroll Memory

• Automatic switch-Off

• Real-Time-Clock and Date

• Calibration Mode

• Backlit Display

• Storage Function

• One Time Zero (OTZ)

• Waterproof*

*as defined in IP 68, 1 hour at 0.1 meter

2 in 1

3 in 1

•Chlorine, pH, Stabilizer

•Chlorine, pH, Alkalinity-M

•Chlorine, pH, Alkalinity-M (total)

•Chlorine LR, Chlorine HR, Chlorine dioxide

4 in 1

•Chlorine, pH, Stabilizer, Alkalinity-M,

•Chlorine, pH, Stabilizer, Alkalinity-M (total)

5 in 1

•Chlorine, pH, Stabilizer, Alkalinity-M, Calcium hardness

6 in 1

•Chlorine, Bromine, pH,Stabilizer, Alkalinity-M, Calcium hardness

Chlorine, pH

Page 14: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected]

PCMultidirectPhotometer

ORDERING INFORMATION

ORDERING INFORMATION

Model Description

21 40 20 MD600, Modern mobile photometer

Model Description

21 00 00 Multidirect Photometer System

®

Lo

vib

on

dT

into

me

ter

Alkalinity-M

Alkalinity-P

Aluminium

Ammonia

Bromine

Chloride

Chlorine

Chlorine Dioxide

Chromium

COD

Copper

DEHA

Fluoride

Hydrogen Peroxide

Iron

Modern, Mobile Photometer System

The MultiDirect is a contemporary, microprocessor-controlled photometer with ergonomically

designed keypad and large-format graphic display. It is equipped with a wide range of

preprogrammed methods based on the proven range of Lovibond® tablet reagents, liquid

reagents, tube tests and powder reagents (VARIO Powder Packs). Users can also store their own methods.

The MultiDirect is a filter photometer using interference filters at 6 different wavelengths. The unique design

of the optics allows the automatic selection of the required wavelength without any moving parts. This and

the dual beam technology utilizing an internal reference channel, guarantees the highest accuracy.

The MultiDirect Photometer can be used for the following tests:

Photometer

PCmultidirect Photometer System

With the modern design of the MD 600 we have succeeded in combining the

mobility of a portable photometer with the characteristics of a modern

laboratory photometer.

This unit covers all the important parameters of water analysis, from aluminium to zinc. The high

level of accuracy of Lovibond® reagents and the user-friendly nature of the instrument

guarantee rapid and reliable analysis of your water samples. Depending on the application, the

unit will operate with tablet reagents, powder packs, liquid reagents or tube tests (16 / 13 mm).

Highlights

• Automatic wavelength selection

• Easy handling

• Backlit display

• Storage (upto 1000 data)

• More than 120 methods

• 35 user defined methods

• Infrared interface

• Waterproof*

• Mobile

*as defined in IP 68, 1 hour at 0.1 meter

Highlights

• Dual Beam Technology and interference

Filters for highest accuracy

• A wide range of pre-programmed methods

• Long-term stable LEDs as light sources

• Update of new methods and languages via

internet (free of charge)

• Interface

• Memory for 1000 data sets Mobile

MD600Photometer

Manganese

Molybdate

Nitrate Vario

Nitrite

Ozone

PH MB

Phosphate

Potassium

Silica

Sulphte

Sulphide

Sulphite

Nitrogen Total LR

Nitrogen Total HR

Urea

Zinc

Page 15: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected] 103

SpectroDirect

ORDERING INFORMATION

Model Description

71 20 05 Spectrophotometer SpectroDirect

®

Lo

vib

on

dT

into

me

ter

ORDERING INFORMATION

Model Description

511052BT Reagent Tablet, DPD No. 1, Pack of 500

511532 Reagent Tablet, DPD No. 2, 500

511082BT Reagent Tablet, DPD No. 3, Pack of 500

511222BT Reagent Tablet, DPD No. 4, Pack of 500

515371BT Low Range Tablets,Iron LR, Pack of 250

515381 High Range Tablets, Iron HR, Pack of 250

513171 Ozone Tables, Pack of 250

513130 Reagent Tablet, Silica No.1, Pack of 100

513140 Reagent Tablet, Silica No .2, Pack of 100

511752BT Phenol Red Tablet, Phenol Red, Pack of 500

Tablet Reagents

Spectrophotometer SpectroDirectSpectrophotometer for water and waste water testing 330 - 900 nm

The SpectroDirect is a modern single-beam spectrophotometer with an excellent

price/performance ratio that is specifically designed for water testing. The instrument is

equipped with a wide range of pre-programmed methods based on the proven range of ®

Lovibond tube tests, tablet reagents, liquid reagents and powder reagents (Vario Powder Packs).

Functions

• Pre-programmed Lovibond® methods

• Absorption

• Transmission

• Spectral data recording

• User calibration (polynomials)

• Concentration (linear)

• Kinetics

Alkalinity-MAlkalinity-PAluminiumAmmoniaArsenicBromineCadmium

The SpectroDirect can be used for the following tests:

ChlorideChlorineChlorine HRChlorine DioxideChromiumCODCopper

CyanideDEHAFluorideFormaldehydeHazen/APHAHydrogen PeroxideIron

LeadManganeseMolybdateNickelNitrateNitriteOzone

pH valuePhenolsPhosphatePotassiumSilicaSpectr. Absorption CoefficientSulphate Vario

SulphideSulphiteSurfactantsTOCTurbidityZincUrea

Highlights

• Use of round vials and rectangular cells of different sizes without adapter

• 330 to 900 nm

• Interface RS232

• Large illuminated display

• Touch-sensitive film keypad with logical layout

• 35 user-specific methods

• Fast, easy lamp change

• Update via internet

A testing system is only as good as the quality of its indicator ® system. This is why Lovibond tablet reagents with a 5 or 10

year guaranteed shelf life are generally used for the standard

test methods. Each tablet is individually sealed in aluminium

foil and is therefore unaffected by ambient conditions. It

remains "fresh” right up to the time it is removed from the

foil, eliminating the possibility of indicator ageing.

Tablet Reagents

The chemicals are of crystalline white nature. If a reagent

(tablets or powder) is not white but has turned grey/brownish

or purple in colour, it has deteriorated. DPD liquid reagents

should be colourless when fresh and may turn brownish in

colour if the reagent has deteriorated. The use of deteriorated

products must be avoided as they will give false results.

Page 16: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected]

ORDERING INFORMATION

ORDERING INFORMATION

Model Description

14 20 00 Lovibond® Comparator 2000+

DB 424 Plastic Cell, 13.5 mm path length, 10ml (Each)

17 10 10 Daylight 2000 Comparator

17 20 30 Nessleriser 2150 with stand, daylight unit and AF 306/P

17 21 50 Nessleriser 2150 with stand

17 20 40 Nessleriser 2250 with stand, daylight unit and DB 420

17 22 50 Nessleriser 2250 with stand

17 10 20 Daylight Unit for Nessleriser

35 30 60 AF 306 Pair Nessler tubes, 113 mm

35 30 80 AF 306/P Pair Nessler tubes, 113 mm with plungers

35 42 00 DB 420 Pair Nessler tubes, 250 mm with plungers

35 31 50 AF 315 Special Nessler tube (determination of oxygen with disc NOE)

Test Code Disc Disc Reading Range

Test Disc, Reagents & Accessories for Comparator System 2000+

Ammonia 28 31 10 NAA 1; 2; 3; 4; 5; 6; 8; 10 µg 1-10 µg NH3

28 31 20 NAB 10; 12; 14; 16; 18; 20; 22; 24; 26 µg 10-26 µg NH3

28 31 30 NAC 28; 32; 36; 40; 44; 48; 52; 56; 60 µg 28-60 µg NH3

28 31 40 NAD 60; 65; 70; 75; 80; 85; 90; 95; 100 µg 60-100 µg NH3

®

Lo

vib

on

dT

into

me

ter

Comparator& Nessleriser

Water Analysis

Disc

Comparator / Color Disc / Nessleriser

With its accessories, the Lovibond® Comparator system 2000+ is an extremely versatile, modular

system for testing water. It is simple to use yet is uncompromising in terms of precision and

reproducibility of results. It is compact and portable. The integrated prism brings the glass

standards of the test discs and the coloured sample into the same field of view.

Lovibond® Comparator 2000+ & Nessleriser System

The system for colorimetric water analysis

Highlights

• More than 400 different test discs available

• Compensation for coloured and turbid samples

• Guaranteed constancy of the coloured glass

standards

• Integrated prism

Discs for Water Analysis

Lovibond® Comparator System 2000+ & Nessleriser

Applications

• Water Treatment (e.g. Drinking Water)

• Pools

• Research Centres

• Universities

• Special Applications

• Laboratory and Field Testing

The system for colorimetric water analysis

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected]

ORDERING INFORMATION

ORDERING INFORMATION

Model Description

14 20 00 Lovibond® Comparator 2000+

DB 424 Plastic Cell, 13.5 mm path length, 10ml (Each)

17 10 10 Daylight 2000 Comparator

17 20 30 Nessleriser 2150 with stand, daylight unit and AF 306/P

17 21 50 Nessleriser 2150 with stand

17 20 40 Nessleriser 2250 with stand, daylight unit and DB 420

17 22 50 Nessleriser 2250 with stand

17 10 20 Daylight Unit for Nessleriser

35 30 60 AF 306 Pair Nessler tubes, 113 mm

35 30 80 AF 306/P Pair Nessler tubes, 113 mm with plungers

35 42 00 DB 420 Pair Nessler tubes, 250 mm with plungers

35 31 50 AF 315 Special Nessler tube (determination of oxygen with disc NOE)

Test Code Disc Disc Reading Range

Test Disc, Reagents & Accessories for Comparator System 2000+

Ammonia 28 31 10 NAA 1; 2; 3; 4; 5; 6; 8; 10 µg 1-10 µg NH3

28 31 20 NAB 10; 12; 14; 16; 18; 20; 22; 24; 26 µg 10-26 µg NH3

28 31 30 NAC 28; 32; 36; 40; 44; 48; 52; 56; 60 µg 28-60 µg NH3

28 31 40 NAD 60; 65; 70; 75; 80; 85; 90; 95; 100 µg 60-100 µg NH3

®

Lo

vib

on

dT

into

me

ter

Comparator& Nessleriser

Water Analysis

Disc

Comparator / Color Disc / Nessleriser

With its accessories, the Lovibond® Comparator system 2000+ is an extremely versatile, modular

system for testing water. It is simple to use yet is uncompromising in terms of precision and

reproducibility of results. It is compact and portable. The integrated prism brings the glass

standards of the test discs and the coloured sample into the same field of view.

Lovibond® Comparator 2000+ & Nessleriser System

The system for colorimetric water analysis

Highlights

• More than 400 different test discs available

• Compensation for coloured and turbid samples

• Guaranteed constancy of the coloured glass

standards

• Integrated prism

Discs for Water Analysis

Lovibond® Comparator System 2000+ & Nessleriser

Applications

• Water Treatment (e.g. Drinking Water)

• Pools

• Research Centres

• Universities

• Special Applications

• Laboratory and Field Testing

The system for colorimetric water analysis

Page 17: Automatic Tintometer -  · PDF filePFXi 995/P Lovibond RYBN, Gardner, Saybolt Colour, ASTM Colour, ... Automatic Tintometer ... ISO 15305 and AOCS Method Cc 13e92

Amkette Analytics Ltd., • Tel.: +91-22-6614 1500 • Fax: +91-22-6668 1600 • Email: [email protected] 105

®

Lo

vib

on

dT

into

me

ter

ORDERING INFORMATION

Test Code Disc Disc Reading Range

Test Disc, Reagents & Accessories for Comparator System 2000+

Chlorine 23 40 60 3/40E 0.02; 0.04; 0.06; 0.08; 0.1; 0.15; 0.2; 0.25; 0.3 mg/l 0.02-0.3 mg/l

free, 29 59 20 0.02; 0.04; 0.06; 0.08; 0.1; 0.2; 0.3; 0.4; 0.5 mg/l 0.02-0.5 mg/l

combined, 23 40 70 3/40F 0.2; 0.25; 0.3; 0.35; 0.4; 0.5; 0.6; 0.7; 0.8 mg/l 0.2-0.8 mg/l

total 23 40 30 3/40G 1.5; 1.8; 2.0; 2.3; 2.5; 2.7; 3.0; 3.2; 3.5 mg/l 1.5-3.5 mg/l

23 40 10 3/40A 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l 0.1-1.0 mg/l

23 41 10 3/40T 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l 0.1-1.0 mg/l

23 39 60 3/40N 1.1; 1.2; 1.3; 1.4; 1.5; 1.6; 1.7; 1.8; 2 mg/l 1.1-2.0 mg/l

23 41 40 3/40J 0.1; 0.2; 0.3; 0.4; 0.6; 0.8; 1; 1.5; 2 mg/l 0.1-2.0 mg/l

23 40 20 3/40B 0.2; 0.4; 0.6; 1; 1.5; 2; 2.5; 3; 4; mg/l 0.2-4.0 mg/l

23 39 30 3/40K 0.5; 1; 1.5; 2; 2.5; 3; 4; 5; 6 mg/l 0.5-6.0 mg/l

23 40 90 3/40S 1; 1.2; 1.4; 1.6; 1.8; 2; 2.5; 3; 4 mg/l 1.0-4.0 mg/l

23 39 20 3/40P 2; 2.3; 2.5; 2.7; 3; 3.2; 3.6; 4; 5 mg/l 2.0-5.0 mg/l

23 40 81 3/40HN 2; 3; 4; 5; 6; 7; 8; 9; 10 mg/l 2.0-10 mg/l

23 39 90 3/40CZ 0.5; 1; 1.5; 2; 4 mg/l Cl2 7; 7.4; 7.6; 8 pH; 0.5-4 mg/l Cl2, 7-8pH

23 20 10 3/2A 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l 0.1-1.0 mg/l

23 20 20 3/2AB 0.15; 0.25; 0.5; 0.75; 1; 1.25; 1.5; 1.75; 2 mg/l 0.15-2.0 mg/l

23 20 50 3/2APC 1; 1.5; 2; 2.5; 3; 3.5; 4; 4.5; 5 mg/l 1.0-5.0 mg/l

Chlorine free 28 34 50 NDPB 0.01; 0.02; 0.03; 0.04; 0.05; 0.06; 0.07; 0.08; 0.1 mg/l 0.01-0.1 mg/l

combined, 28 34 60 NDPC 0.02; 0.04; 0.06; 0.08; 0.1; 0.12; 0.14; 0.16; 0.2 mg/l 0.02-0.2 mg/l

total 28 34 40 NDP 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.35; 0.4; 0.5 mg/l 0.05-0.5 mg/l

28 34 70 NDPD 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l 0.1-1.0 mg/l

29 79 70 3/40ED 0.04; 0.08; 0.11; 0.15; 0.19; 0.28; 0.38; 0.48; 0.57 mg/l 0.04-0.57 mg/l

29 87 50 3/40FD 0.38; 0.48; 0.57; 0.66; 0.76; 0.95; 1.14; 1.33; 1.52 mg/l 0.38-1.52 mg/l

23 05 70 3/157 0.25; 0.5; 0.75; 1; 1.25; 1.5; 2; 3; 5 mg/l 0.25-5.0 mg/l

Chromium 23 59 00 3/59 10; 20; 30; 40; 50; 60; 70; 80; 100 µg 10-100 µg

Hardness total 23 10 70 4/38 0; 5; 10; 15; 20; 25; 30; 40; 60 mg/l CaCO3 0-60 mg/l

Hydrazine 28 37 00 NOH 0; 0.5; 1; 2; 3; 4; 6; 8; 10 µg 0-10 µg/l

Hydrogen 23 50 10 3/50 B 0.1; 0.2; 0.3; 0.4; 0.6; 1; 1.5; 2; 3 mg/l 0.1-3 mg/l

Peroxide 23 50 20 3/50 E 0.01; 0.02; 0.03; 0.04; 0.05; 0.07; 0.09; 0.12; 0.15 mg/l 0.01-0.15 mg/l

Ozone 23 67 00 3/67 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l 0.1-1.0 mg/l

23 67 10 3/67A 0.01; 0.02; 0.03; 0.04; 0.05; 0.06; 0.07; 0.08; 0.1 mg/l 0.01-0.1 mg/l

23 67 70 3/67S 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.35; 0.4; 0.45 mg/l 0.05-0.45 mg/l

23 04 40 3/148 0; 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.4; 0.5 mg/l 0-0.5 mg/l

pH 22 10 10 2/1A 1.2; 1.4; 1.6; 1.8; 2.0; 2.2; 2.4; 2.6; 2.8 1.2 - 2.8 pH

22 10 30 2/1B 2.8; 3; 3.2; 3.4; 3.6; 3.8; 4; 4.2; 4.4 2.8 - 4.4 pH

22 10 50 2/1C 3.6; 3.8; 4; 4.2; 4.4; 4.6; 4.8; 5; 5.2 3.6 - 5.2 pH

22 10 80 2/1E 4.4; 4.6; 4.8; 5; 5.2; 5.4; 5.6; 5.8; 6 4.4 - 6.0 pH

22 11 00 2/1G 5.2; 5.4; 5.6; 5.8; 6; 6.2; 6.4; 6.6; 6.8 5.2 - 6.8 pH

22 11 10 2/1H 6; 6.2; 6.4; 6.6; 6.8; 7; 7.2; 7.4; 7.6 6.0 - 7.6 pH

22 11 30 2/1J 6.8; 7; 7.2; 7.4; 7.6; 7.8; 8; 8.2; 8.4 6.8 - 8.4 pH

22 11 40 2/1K 7.2; 7.4; 7.6; 7.8; 8; 8.2; 8.4; 8.6; 8.8 7.2 - 8.8 pH

22 11 90 2/1L 8; 8.2; 8.4; 8.6; 8.8; 9; 9.2; 9.4; 9.6 8.0 - 9.6 pH

22 12 20 2/1P 4; 5; 6; 7; 8; 9; 9.4; 10; 11 4.0 - 11 pH

Phosphate 23 02 70 3/133 0; 0.25; 0.5; 1; 1.5; 2; 2.5; 3; 4 mg/l 0-4.0 mg/l PO4

23 03 10 3/136 0; 5; 10; 15; 20; 25; 30; 35; 40 mg/l 0 - 40mg/l PO4

28 39 50 NMD 10; 20; 30; 40; 50; 60; 70; 80; 100 µg 10-100 µg/l PO4

Silica 28 36 30 NN 1; 2; 4; 6; 8; 10; 12; 16; 20 mg/l 1.0-20mg/l SiO2

28 38 80 NV 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 0.9; 1.0mg/l 0.2-1.0mg/l SiO2

Discs for Water Analysis