Page 1: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

AUXILIARY RELAYS FOR RAILWAY SECTOR.

Page 2: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Moving together

This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products described here.

Page 3: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 3

› Answers for railway applications

› General characteristics

. › Technical standards

› Range of products

› Railway applications

› Instantaneous relays

› Time-Lag relays

› Latching relays

› Breaking capacity

› Pick-up voltage/release voltage-temperature charts

› Model selection

› Dimensions and panel mounting cut-off

INDEX

4.

5.

6.

7.

8.

9.

16.

18.

23.

28.

32.

34.

Page 4: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector4

ARTECHE auxiliary relays are designed to guarantee the best features and complete security even in the hardest working environment.

The design, durability and quality of the different alternatives that ARTECHE relays can offer (FF range and standard range), make them suitable for high responsibility controls in the railway sector, highlighting:

Traction Substations and Station Centres

Interface between infrastructure and rolling stock:

FF RANGE IN THE FOLLOWING APPLICATIONS:

ANSWERS FORRAILWAY APPLICATIONS

ELECTRIFICATION:

INTERLOCKING AND SIGNALLING:

ROLLING STOCK:

› Direct operation on MV / HV (circuit breaker, sectionalizer). › Galvanic isolation between the control system and the primary equipment.

› Applications where high speed operation is a must. › Applications where high breaking capacity is required. › Tripping functions. › Contact multiplication in control systems of HV / MV installations.

› ASFA systems. › RTMC systems. › RTMS systems. › CBTC systems. › ETCS systems. › ATO/ATP/ATS/APR… systems

› Boarding doors locking. › Brake circuit command. › Security loop. › Pantograph control. › Lighting and air conditioned systems operation. › Traction system. › Brake systems.

Page 5: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 5

The main features of ARTECHE’s auxiliary relays are the followings:

In addition, the different number of alternatives that are offered when the equipment is selected, both technically (increase of the breaking capacity by serial contacts or by the magnetic blow out, high speed operation of the output contacts, possibility of adding different options to the relay) and in the assembly method (front, rear or flush mounted sockets, with screws or fastons) must be considered.

› Security contacts (EN 50205 Standard). › Capable to withstand vibrations and seismic conditions (EN 61373; IEEE 344; IEEE 323; IEEE C37.98 Standards).

› Capable to operate under low duty loads, activate digital inputs, and operate without any load. FF Range.

› Wide range of auxiliary voltage levels (Vdc and Vac).

› Sturdy design. › High speed operation (up to 3 ms). › Self-cleaning contacts. › Designed to allow continuous operation even in high temperature ambient, within the whole voltage range.

› High level of electrical insulation between input and output circuits.

› Availability of extended voltage range (+25/-30%) for high security applications.

› An internal diode is included to avoid damaging the relay when connecting with inverse polarity.

› In compliance with the most demanding test standards: IEC, EN, IEEE and bearing the CE mark

› High protection degree (IP40), with transparent cover, making them suitable for use in salty and tropical atmospheres.

› Capable to work under ambient of 100% humidity.

› Simplicity of installation (plug-in relays in a wide range of sockets with different installation configurations).

› No need of maintenance after installation.

GENERALCHARACTERISTICS

Page 6: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector6

› EN 60077 Series. Rolling stock equipment. - Part 1: General conditions in service and general terms. - Part 2: Electrotechnical components.

› EN 50155 (IEC 60571 equivalent). Railway applications - Rolling stock equipment.

› IEC 61373. Railway applications - Shock and vibration tests.

› NFF 16-101 and NFF 16-102. Rolling stock fire behaviour. › EN 50205. Relays with forcibly mechanically guided contacts.

In addition to the specific applicable standards, ARTECHE auxiliary relays are designed based on the fulfilment of the following standards:

› IEC 61810: Electromechanical all-or-nothing relays. › IEC 60255: Electrical relays. Measuring relays and protection equipment.

› IEC 61812: Specified time relays for industrial use. › IEC 60947: Low-voltage switchgear and controlgear. . › IEC 61000: Electromagnetic compatibility.

TECHNICAL STANDARDSRAILWAY APPLICABLE STANDARDS

GENERAL STANDARDS

E322124

UL Recognized Component Marks for USA and Canada: The combined UL signs for the USA and Canada are recognized by the authorities of both countries. All auxiliary relays identified with this mark meet the requirements of both countries.

Page 7: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 7

RANGE OF PRODUCTS

ARTECHE’s auxiliary relays with seismic characteristics are designed to work properly perform under frequent vibration and shock applications, as railway sector, or because of safety requirements as nuclear power plants.

They comply with the extended voltage range (+25 / -30 %).

The sturdy design of our equipment, with a higher appropriate pressure between contacts, permits to withstand vibrations without penalizing the good performance of the relays.

ARTECHE’s general purpose auxiliary relays are designed to directly operate to the tripping and control circuit.

Their pick-up time lower than 20 ms and the high breaking capacity of their contacts make them appropriate to be used as an interface between the protection system and the breaker. Furthermore, its multiple output contacts permit to use these relays in control, interlocking, timing and signalling applications as well as per direct operation on HV and MV primary equipment.

The FF range exhaustive process control ensures a proper operation of the contacts in weak loads or even in no load operations.

ARTECHE offers specific relays intended to be used in tripping applications, where the requirements of pick-up time (with models that assure the trip even in less than 3 ms) and the breaking capacity are demanding, as the trip of HV and MV breakers.

These relays include a standard front LED that indicates when the relay is energized. Relay trip flag is available, which indicates when the relay has operated, as a memory state.

All the relays include a diode in parallel with the coil (see auxiliary relays with overvoltage protection characteristic) and comply with the shock and vibration standards, related to the relays with seismic characteristics.

ARTECHE’s auxiliary relays, either Vdc or Vac, have the possibility of including an element in parallel with the coil (diode or varistance).

In applications with overvoltage, where drop-out time is not important, it is recommended to use diode. Otherwise, varistance is more suitable.

These elements are aimed to discharge the energy of the coil when the relay is not longer energized.

These relays are indicated when the customer wish to protect the contact of the equipment that commands the operation of our relay, providing a longer durability of the whole protection and control system.

ROLLING STOCK / SIGNALLING

ELECTRIFICATION

SIGNALING

Auxiliary relays with seismic characteristics

General purpose auxiliary relays

Auxiliary tripping relays

Auxiliary relays with coil overvoltage protection

Instantaneous, latching and timer relays.

Instantaneous, latching and timer relays.

Instantaneous relays.

Page 8: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector8

MODEL ROLLING STOCK(FF Range)

SIGNALING(FF Range)

INFRASTRUCTURE CONTACTS WELD NO TRANSFER CONTACTS

Instantaneous

RD-2SY • • • 2 CO •

RF-4SY • • • 4 CO •

RJ-8SY • • • 8 CO •

RD-2SYDI / RD-2SYV • • • 2 CO •RF-4SYDI / RF-4SYV • • • 4 CO •

RJ-8SYDI / RJ-8SYV • • • 8 CO •RD-2 • • 2 CO •RF-4 • • 4 CO •

RJ-8 • • 8 CO •

RD-2DI / RD-2V • • 2 CO •

RF-4DI / RF-4V • • 4 CO •

RJ-8DI / RJ-8V • • 8 CO •

Timers

TDF-2 • • • 2 CO •TDF-4 • • • 4 CO •

TDF-22 • • • 4 CO(2 inst. + 2 timed)

TDJ-8 • • • 8 CO •

TDJ-44 • • • 8 CO(4 inst. + 4 timed)

Latching

BF-3 • • • 3 CO

BF-4 • • • 4 CO

BJ-8 • • • 8 CO

BF-3BB • • • 3 CO

BF-4BB • • • 4 CO

BJ-8BB • • • 8 CO

Trip

RD-2R • • 2 CO •RD-2XR • • 2 CO •

RF-4R • • 4 CO •

RF-4XR • • 4 CO •

RJ-8R • • 8 CO •

RJ-8XR • • 8 CO •

BF-3R • • 3 CO

BF-4R • • 4 CO

BF-4RP • • 4 CO

BJ-8R • • 8 CO

BJ-8RP • • 8 CO

RAILWAY APPLICATIONS

FF Range: Capable to operate under low duty loads, activate digital inputs, and operate without any load: general applications, as for rolling stock as for signaling.

Page 9: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

9Auxiliary relays | Railway sector

› World-class range of auxiliary relays for energy sector, specially designed for the most demanding applications

TECHNICAL FEATURES PER MODEL

Page 10: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector10

Model RD-2 RF-4 RJ-8

Applications Operate directly to the tripping and control circuit.

Construction characteristics

Contacts no. 2 Changeover 4 Changeover 8 Changeover

Connections

Options With OP options With OP options - Push-to-test button included

Weight (g) 125 250 500

Dimensions (mm) 22,5 x 50,4 x 72 (D short) 42,5 x 50,4 x 72 (F short) 82,5 x 50,4 x 72 (J short)

Coil characteristics

Standard voltages(1) 24, 48, 72, 110, 125, 220 Vdc / 24, 48, 63,5, 110, 127, 230, 400 (4) Vac (50-60 Hz)

Voltage range +10% -20% UN

Pick-up / release voltage See pick-up/release voltage-temperature curves

Consumptions in permanence (UN) 2,6 W; 3,3 VA 3,9 W; 6,6 VA 6 W; 11 VA

Operating time

Pick-up time <20 ms

Drop-out time Vdc: <10 ms • Vac: <50msWith LED: <50ms

Vdc: <15 ms • Vac: <50 msWith LED: <50 ms

Contacts

Contact material AgNi

Contacts resistance(2) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,8 mm

Permanent current 10 A

Instantaneous current 30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc

Breaking capacity See breaking capacity curves (Contact configuration type A)

Max. breaking capacity See value for 50,000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature -40ºC +70ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(3) <2000 m

GENERAL PURPOSE INSTANTANEOUS RELAYS

(1) Other voltage upon request (2) Guarantee data for relays just manufactured

(3) Ask for higher altitudes (4) Voltage not recognized by UL

7

5

8

6

3

4

(+)

1(-)

2

50

51

60

61

70

31

40

41

5

6

7

8

(+)

a(-)

d

10

11

20

21

30

71

80

81

1

2

3

4

11

7

12

8

13

9

14

10

3

4

5

6(+)

1(-)

2

Page 11: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 11

Model RD-2R RD-2XR RF-4R RF-4XR

ApplicationsIntended for tripping applications where high demanding requirements in operating time

(with tripping time from 8ms to 3 ms) and breaking capacity are needed,that is the case of tripping HV and MV circuit breakers.

Construction characteristics

Contacts no. 2 Changeover 4 Changeover

Connections

Options With 0P options • LED included • Diode in parallel with the coil included

Weight (g) 125 250

Dimensions (mm) 22,5 x 50,4 x 72 (D short Type) 42,5 x 50,4 x 72 (F short Type)

Coil characteristics

Standard voltages(1) 24, 48, 110, 125, 220, 250 (4) Vdc /110, 127, 230 Vac (50-60Hz)

24, 48, 110, 125, 220, 250 Vdc

24, 48, 110, 125, 220, 250 (4) Vdc / 110, 127, 230 Vac (50-60 Hz)

24, 48, 110, 125, 220, 250 (4) Vdc

Voltage range +10% -20% UN

Pick-up / release voltage See pick-up/release voltage-temperature curves

Consumptions - In permanence (UN)

Peak • ≤96 Vdc

Peak • >96 Vdc

0,95 W 1 W

0,8 A / 20 ms 2,5 A / 20 ms 0,8 A / 20 ms 2,5 A / 20 ms

0,3 A / 20 ms 0,8 A / 20 ms 0,3 A / 20 ms 0,8 A / 20 ms

Operating time

Pick-up time <8 ms (<10 ms Vac) <5,5 ms <8 ms (<10 ms Vac) <5,5 ms

Drop-out time Vdc: <40 msVac: <50 ms

Vdc: <40 ms Vdc: <40 msVac: <50 ms

Vdc: <40 ms

Contacts

Contact material AgNi

Contacts resistance(2) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,2 mm

Permanent current 10 A

Instantaneous current 30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc

Breaking capacity See breaking capacity curves (Contact configuration type B)

Max. breaking capacity See value for 50.000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature -25ºC +70ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(3) <2000 m

TRIP RELAYS (I)

(1) Other voltage upon request (2) Guarantee data for relays just manufactured

(3) Ask for higher altitudes (4) Voltage not recognized by UL

(+)

1(-)

2

11

7

12

8

13

9

14

10

3

4

5

6

7

5

8

6

3

4

(+)

1(-)

2

Page 12: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector12

Model RJ-8R RJ-8XR RJ-4XR4

ApplicationsIntended for tripping applications where high quality requirements in operating time (with models even tripping in less than 3 ms) and breaking

capacity are needed, that is the case of tripping HV and MV circuit breakers.

Construction characteristics

Contacts no. 8 Changeover 4 Changeover(5)

Connections

Options With 0P options • LED included • Diode in parallel with the coil included

Weight (g) 500 335

Dimensions (mm) 82,5 x 50,4 x 72 (J short type) 42,5 x 50,4 x 82,5 (F short Type)

Coil characteristics

Standard voltages(1) 24, 48, 110, 125, 220, 250 (4) Vdc / 110, 127, 230 Vac

(50-60 Hz)24, 48, 110, 125, 220,

250(4) Vdc110, 125, 220, 250 (4) Vdc

Voltage range +10% -20% UN +15% -20% UN

Pick-up / release voltage See pick-up/release voltage-temperature curves

Consumptions - In permanence (UN)

Peak • ≤96 Vdc

Peak • >96 Vdc

1,4 W 6,5 W

0,8 A / 20 ms 2,5 A / 20 ms 25 W / 5 ms

0,3 A / 20 ms 0,8 A / 20 ms

Operating time

Pick-up time <8 ms Vdc (<10 ms Vac)(Range 24 Vdc <10 ms)

<6,5 ms Contacts 1-4: <3 msContacts 5-8: <20 ms

Drop-out time Vdc: <40 msVac: <50 ms

Vdc: <40 ms Contacts 1-4: <25 ms Contacts 5-8: <50 ms

Contacts

Contact material AgNi Contacts 1-4: AgNi 10 Contacts 5-8: Ag1000

Contacts resistance(2) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,2 mm Contacts 5-8: 1,2 mm

Distance between contacts 10 A Contacts 5-8: 15 A Contacts 1-4: 8 A

Instantaneous current 30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc

Breaking capacity See breaking capacity curves (Contact configuration type B)

Max. breaking capacity See value for 50,000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature -25ºC +70ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(3) <2000 m

(1) Other voltage upon request (2) Guarantee data for relays just manufactured

(3) Ask for higher altitudes (4) Voltage not recognized by UL

TRIP RELAYS (II)

50

51

60

61

70

31

40

41

5

6

7

8

10

11

20

21

30

71

80

81

1

2

3

4

(+)

a(-)

d

50

51

60

61

70

31

40

41

5

6

7

8

10

11

20

21

30

71

80

81

1

2

3

4

(+)

a(-)

d

Hig

h b

reak

ing

cap

acit

yTr

ip

(5) 4 Changeover + 4 Fast Singles-Inversors without break power

Page 13: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 13

INSTANTANEOUS RELAYS WITH SEISMIC CHARACTERISTICSModel RD-2SY RF-4SY RJ-8SY

ApplicationsFrequent vibration and shock applications, as railway sector, or because of safety

requirements as nuclear power plants.

Construction characteristics

Contacts no. 2 Changeover 4 Changeover 8 Changeover

Connections

Options With OP options With OP options / Push-to-test button included

Weight (g) 125 250 500

Dimensions (mm) 22,5 x 50,4 x 72(D short type)

42,5 x 50,4 x 72(F short type)

82,5 x 50,4 x 72(J short type)

Coil characteristics

Standard voltages(1) 24, 48, 72, 110, 125, 220 Vdc 24, 48, 63,5, 110, 127, 230, 400 (4) Vac (50-60 Hz)

Voltage range +25% -30% UN

Pick-up / release voltage See pick-up/release voltage-temperature curves

Consumptions in permanence (UN) 2,6 W; 3,3 VA 3,9 W; 6,6 VA 6 W; 11 VA

Operating time

Pick-up time < 20 ms

Drop-out time Vdc: <10 ms / Vac: <50 ms / With LED

Vdc: <15 ms / Vac: <50 ms / With LED

Contacts

Contact material AgNi

Contacts resistance(2) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,2 mm

Permanent current 10 A

Instantaneous current 30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc

Breaking capacity See breaking capacity curves (Contact configuration type B)

Max. breaking capacity See value for 50,000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature -40ºC +70ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(3) <2000 m

(1) Other voltage upon request (2) Guarantee data for relays just manufactured

7

5

8

6

3

4

(+)

1(-)

2

11

7

12

8

13

9

14

10

3

4

5

6(+)

1(-)

2

50

51

60

61

70

31

40

41

5

6

7

8

(+)

a(-)

d

10

11

20

21

30

71

80

81

1

2

3

4

(3) Ask for higher altitudes (4) Voltage not recognized by UL

Page 14: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector14

INSTANTANEOUS RELAYS WITH COIL OVERVOLTAGE PROTECTION (I)

Model RD-2DI • RD-2V (4) RF-4DI • RF-4V (4) RJ-8DI • RJ-8V (4)

Applications Intended to protect the contact of the equipment that feeds the coil in our relay.

Construction characteristics

Contacts no. 2 Changeover 4 Changeover 8 Changeover

Connections

Options With OP options With OP options / Push-to-test button included

Weight (g) 125 250 500

Dimensions (mm) 22,5 x 50,4 x 72 (D short type)

42,5 x 50,4 x 72(F short type)

82,5 x 50,4 x 72(J short type)

Coil characteristics

Standard voltages(1) 24, 48, 72, 110, 125, 220 Vdc 24, 48, 63,5, 110, 127, 230, 400 (4) Vac (50-60 Hz)

Voltage range +10% -20% UN

Pick-up / release voltage See pick-up/release voltage-temperature curves

Consumptions in permanence (UN) 2,6 W; 3,3 VA 3,9 W; 6,6 VA 6 W; 11 VA

Operating time

Pick-up time < 20 ms

Drop-out time V Series: <25ms / DI Series: <50 ms

Contacts

Contact material AgNi

Contacts resistance(2) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,8 mm

Permanent current 10 A

Instantaneous current 30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc

Breaking capacity See breaking capacity curves (Contact configuration type A)

Max. breaking capacity See value for 50,000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature -40ºC +70ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(3) <2000 m

(1) Other voltage upon request (2) Guarantee data for relays just manufactured

(3) Ask for higher altitudes (4) Voltage not recognized by UL

7

5

8

6

3

4

(+)

1(-)

2

(+)

1(-)

2

RD

-2D

IR

D-2

V

(+)

1(-)

2

(+)

1(-)

2

RF

-4D

IR

F-4

V

11

7

12

8

13

9

14

10

3

4

5

6

50

51

60

61

70

31

40

41

5

6

7

8

10

11

20

21

30

71

80

81

1

2

3

4

(+)

a(-)

d

(+)

a(-)

d

RJ-

8D

IR

J-8

V

Page 15: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 15

INSTANTANEOUS RELAYS WITH COIL OVERVOLTAGE PROTECTION (II)

Model RD-2SYDI • RD-2SYV (4) RF-4SYDI • RF-4SYV (4) RJ-8SYDI RJ-8SYV (4)

ApplicationsFrequent Vibration and Shock applications, as railway sector, or because of safety requirements as nuclear

power plants. Intended to protect the contact of the equipment that feeds the coil in our relay.

Construction characteristics

Contacts no. 2 Changeover 4 Changeover 8 Changeover

Connections

Options With OP options With OP options Push-to-test button included

Weight (g) 125 250 500

Dimensions (mm) 22,5 x 50,4 x 72(D short type)

42,5 x 50,4 x 72(F short type)

82,5 x 50,4 x 72(J short type)

Coil characteristics

Standard voltages(1) 24, 48, 72, 110, 125, 220 Vdc 24, 48, 63,5, 110, 127, 230, 400 (4) Vac (50-60 Hz)

Voltage range +25% -30% UN

Pick-up / release voltage See pick-up/release voltage-temperature curves

Consumptions in permanence (UN) 2,6 W; 3,3 VA 3,9 W; 6,6 VA 6 W; 11 VA

Operating time

Pick-up time < 20 ms

Drop-out time V Series: <25ms • DI Series: <50 ms

Contacts

Contact material AgNi

Contacts resistance(2) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,2 mm

Permanent current 10 A

Instantaneous current 30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc

Breaking capacity See breaking capacity curves (Contact configuration type B)

Max. breaking capacity See value for 50,000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature -40ºC +70ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(3) <2000 m

(1) Other voltage upon request (2) Guarantee data for relays just manufactured

(3) Ask for higher altitudes (4) Voltage not recognized by UL

7

5

8

6

3

4

(+)

1(-)

2

(+)

1(-)

2

RD

-2SY

DI

RD

-2SY

V

(+)

1(-)

2

(+)

1(-)

2

RF

-4SY

DI

RF

-4SY

V

11

7

12

8

13

9

14

10

3

4

5

6

50

51

60

61

70

31

40

41

5

6

7

8

10

11

20

21

30

71

80

81

1

2

3

4

(+)

a(-)

d

(+)

a(-)

d

RJ-

8SY

DI

RJ-

8SY

V

Page 16: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector16

Model TDF-2 TDF-4 TDF-22

Applications Electrical command timing

Construction characteristics

Timing Contacts no. 2 Changeover 4 Changeover 2 Changeover

Instantaneous contact no. 0 Changeover 0 Changeover 2 Changeover

Connections

Options With OP options

Weight (g) 265

Dimensions (mm) 42,5 x 50,4 x 96,6 (F large type)

Coil characteristics

Standard voltages(1) 24, 48, 72, 96, 110, 125, 250 (4) Vdc/Vac (50-60 Hz)

Voltage range +25% -30% UN (except range 250) (4)

Pick-up / release voltage See power supply-temperature charts for time-lag relays

Consumptions In permanence (UN) ≤3,2 W ≤4 W ≤5,5 W

Operating time

Time range between 0,03 s y 99 h

Pick-up time < 23 ms

Drop-out time < 40 ms

Contacts

Contact type 2 Changeover 4 Changeover

Contact material AgNi (FF Range)

Contact resistance(2) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,2 mm

Permanent current 10 A

Instantaneous current 30 A 0 A during 1s / 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc 30 A / 1 s / 36 Vdc / 30.000 operations (1 op / 15 s)

Breaking capacity See breaking capacity curves (Contact configuration type B)

Max. breaking capacity See value for 50,000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature Up to 125 Vdc: -40ºC +70ºC / 220 Vdc - 250 Vdc: -40º+55ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(3) <2000 m

TIME-LAG RELAYS (I)

(1) Other voltage upon request (2) Guarantee data for relays just manufactured

(3) Ask for higher altitudes (4) Voltage not recognized by UL

+2-

1A1 B1

TEMP

11

7

12

8

13

9

14

10

3

4

5

6

+2-

1A1 B1

TEMP

11

7

12

8

13

9

14

10

3

4

5

6

INST

13

9

14

10

5

6

+1-

2B1 A1

TEMP

Page 17: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 17

Model TDJ-8 TDJ-44

Applications Electrical Command Timing

Construction characteristics

Timing Contacts no. 8 Changeover 4 Changeover

Instantaneous contact no. 0 Changeover 4 Changeover

Connections

Options With OP options

Weight (g) 500

Dimensions (mm) 82,5 x 50,4 x 96,6 (J large type)

Coil characteristics

Standard voltages(1) 24, 48, 72, 96, 110, 125, 250 (4) Vdc/Vac (50-60 Hz)

Voltage range +25% -30% UN (except range 250 (4): +10% -20%))

Pick-up / release voltage See power supply-temperature charts for time-lag relays

Consumptions Permanencia (UN) ≤7,5 W ≤10 W

Operating time

Time Range between 0,03 s y 99 h

Pick-up time <23 ms

Drop-out time <40 ms

Contacts

Contact type 8 Changeover

Contact material AgNi (Gama FF)

Contact resistance (2) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,2 mm

Permanent current 10 A

Instantaneous current 30 A 0 A during 1s / 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc30 A / 1 s / 36 Vdc / 30.000 operations (1 op / 15 s)

Breaking capacity See breaking capacity curves (Contact configuration type B)

Max. breaking capacity See value for 50,000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature Up to 125 Vdc: -40ºC +70ºC / 220 Vdc - 250 Vdc: -40º+55ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(2) <2000 m

TIME-LAG RELAYS (II)

(1) Other voltage upon request (2) Guarantee data for relays just manufactured

(3) Ask for higher altitudes (4) Voltage not recognized by UL

50

51

60

61

70

31

40

41

5

6

7

8

10

11

20

21

30

71

80

81

1

2

3

4

+c-

b

a d

TEMP

+-

50

51

60

61

70

31

40

41

5

6

7

8

10

11

20

21

30

71

80

81

1

2

3

4

+c-

b

a d

TEMP

+-

INST

Page 18: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector18

(1) Other voltage upon request (2) Ask for higher altitudes(3) Typical data for newly manufactured relays

GENERAL PURPOSE LATCHING RELAYSModel BF-3 BF-4 BJ-8

Applications Relays with two stable positions. Required when the position memory(open-close, automatic-manual, local-remote...) is needed.

Construction characteristics

Contacts no. 3 Changeover 4 Changeover 8 Changeover

Connections

Options Options are not available

Weight (g) 300 600

Dimensions (mm) 45 x 45 x 96,5 (F short Type) 90 x 50 x 100,5(J short Type)

Coil characteristics

Standard voltages(1) 24, 48, 72, 110, 125, 220 Vdc / 63,5, 110, 127, 230 Vac (50-60 Hz)

Voltage range +25% -30% UN

Pick-up voltage See pick-up voltage / temperature curves for Latching relays

Consumptions only in the change-over ≤6 W ≤12 W

Operating time

Pick-up time <20 ms

Contacts

Contact material AgNi

Contact resistance(3) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,8 mm

Permanent current 10 A

Instantaneous current 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc

Breaking capacity See breaking capacity curves (Contact configuration type A)

Max. breaking capacity See value for 50.000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature -40ºC +70ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(2) <2000 m

B1

11

7

12

8

13

9

14

10

3

4

5

6

Reset+

+1

-2

Set

b

Reset+

+d

Set

-c

-a

50

51

60

61

70

31

40

41

5

6

7

8

10

11

20

21

30

71

80

81

1

2

3

4

11

7

12

8

13

9

3

4

5

14

Reset+

+2

Set

-1

-10

Page 19: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 19

(1) Other voltage upon request (2) Ask for higher altitudes(3) Typical data for newly manufactured relays

TRIP AND LOCKOUT RELAYS (I)Model BF-3R BF-4R BJ-8R

Applications Intended for trip and lockout applications where high demanding requirements in operating time and breaking capacity are needed.

Construction characteristics

Contacts no. 3 Changeover 4 Changeover 8 Changeover

Connections

Options Options are not available

Weight (g) 300 600

Dimensions (mm) 45 x 45 x 96,5 (F short Type) 90 x 50 x 100,5(J short Type)

Coil characteristics

Standard voltages(1) 24, 48, 72, 110, 125, 220 Vdc / 63,5, 110, 127, 230 Vac (50-60 Hz)

Voltage range +10% -20% UN

Pick-up voltage See pick-up voltage / temperature curves for Latching relays

Consumptions only in the change-over 27 W 23 W 35,5 W

Operating time

Pick-up time <10 ms (Vdc) <20 ms (Vac) <10 ms (Vdc) <20 ms (Vac)

Contacts

Contact material AgNi

Contact resistance(3) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,8 mm

Permanent current 10 A

Instantaneous current 880 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc

Breaking capacity See breaking capacity curves (Contact configuration type A)

Max. breaking capacity See value for 50.000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature -40ºC +70ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(2) <2000 m

1+

-2

Set -

B1+R

eset =

11

7

12

8

13

9

14

10

3

4

5

6

+d

-c

Set -

+b

-a

Res

et=

50

51

60

61

70

31

40

41

5

6

7

8

10

11

20

21

30

71

80

81

1

2

3

4

+2

-1

Set -

+14

-10

Res

et=

11

7

12

8

13

9

3

4

5

Page 20: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector20

(1) Other voltage upon request (2) Ask for higher altitudes(3) Typical data for newly manufactured relays

TRIP AND LOCKOUT RELAYS (II)Model BF-4RP BJ-8RP

Applications Intended for tripping and locking applications where high quality requirements in operating time and breaking capacity are needed, with manual reset.

Construction characteristics

Contacts no. 4 Changeover 8 Changeover

Connections

Options Options are not available

Weight (g) 300 600

Dimensions (mm) 45 x 45 x 96,5 (F short Type) 90 x 50 x 100,5 (J short Type)

Coil characteristics

Standard voltages(1) 24, 48, 72, 110, 125, 220 Vdc63,5, 110, 127, 230 Vac (50-60 Hz)

Voltage range +10% -20% UN

Pick-up voltage (20ºC) See pick-up voltage / temperature curves for Latching relays

Consumptions only in the change-over 23 W 35,5 W

Operating time

Pick-up time <10 ms (Vdc) <13 ms (Vac) <10 ms (Vdc) <20 ms (Vac)

Contacts

Contact material AgNi

Contact resistance(3) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,8 mm

Permanent current 10 A

Instantaneous current 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc

Breaking capacity See breaking capacity curves (Contact configuration type A)

Max. breaking capacity See value for 50,000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature -40ºC +70ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(2) <2000 m

1+

-2

Set -

B1+R

eset =

11

7

12

8

13

9

14

10

3

4

5

6

+d

-c

Set -

+b

-a

Res

et=

50

51

60

61

70

31

40

41

5

6

7

8

10

11

20

21

30

71

80

81

1

2

3

4

Page 21: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 21

LATCHING RELAYS WITH COIL OVERVOLTAGE PROTECTIONModel BF-3BB BF-4BB BJ-8BB

Applications Intended to protect the contact of the equipment that feeds the coil in our relay.

Construction characteristics

Contacts no. 3 Changeover 4 Changeover 8 Changeover

Connections

Options Options are not available

Weight (g) 300 600

Dimensions (mm) 45 x 45 x 96,5 (F large Type) 90 x 50 x 100,5 (J large Type)

Coil characteristics

Standard voltages(1) 24, 48, 72, 110, 125, 220 Vdc(3)

Voltage range +25% -30% UN

Pick-up voltage See pick-up voltage / temperature curves for Latching relays

Consumptions only in the change-over ≤6 W ≤12 W

Operating time

Pick-up time <20 ms

Contacts

Contact material AgNi

Contact resistance(4) ≤ 30 mΩ (Range standard) / ≤ 15 mΩ (Range FF)

Max. contacts resistance 40 mΩ at 10 A (Range FF)

Distance between contacts 1,8 mm

Permanent current 10 A

Instantaneous current 80 A during 200 ms / 200 A during 10 ms

Wetting current/voltage 12 Vdc, 10 mA (range FF)

Max. making capacity 40 A / 0,5 s / 110 Vdc

Breaking capacity See breaking capacity curves (Contact configuration type A)

Max. breaking capacity See value for 50,000 operations

Umax opened contact 250 Vdc / 400 Vac

General data

Mechanical endurance 107 operations

Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)

Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)

Insulation resistance >1000 GΩ

Operating temperature -40ºC +70ºC

Storage temperature -40ºC +85ºC

Max. operating humidity 93% / +40ºC

Operating altitude(2) <2000 m

(1) Other voltage upon request (2) Ask for higher altitudes

1+

-2

Set -

B1+R

eset =

11

7

12

8

13

9

14

10

3

4

5

6

+2

-1

Set -

+14

-10

Res

et=

11

7

12

8

13

9

3

4

5

+d

-c

Set -

+b

-a

Res

et=

50

51

60

61

70

31

40

41

5

6

7

8

10

11

20

21

30

71

80

81

1

2

3

4

(3) Vac voltages upon request(4) Typical data for newly manufactured relays

Page 22: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

22 Relés auxiliares | Aplicaciones ferroviarias

BREAKING CAPACITY

› With devices operating worldwide, also heavy industries like oil & gas sector trust in our relays.

Page 23: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 23

24 Vdc voltageDifferent loads configurations.

The breaking capacity is a critical parameter on the design and the applications of the relays. Its mechanical life could be considerably reduced, depending on the value of the load (especially with heavy duty loads), the number of operations and the environmental conditions in which the relay is operating.

In any configuration, ARTECHE’s auxiliary relays have a high breaking capacity values. These limits are showed in the table below, in terms of power and current values. In all the cases, these relays guarantee a right performance during 50,000 operations.

Likewise, the values showed in the following charts have been obtained in standard conditions in the laboratory, and they could be different in real conditions. In any case, the possibility of connecting serial contacts or a bigger distance between contacts makes these values to be considerably increased.

BREAKING CAPACITY

10000

100000

1000000

10000000

0,00 5,00 10,00 15,00 20,00 25,00 0 5 10

107

106

105

104

No

. op

erat

ions

No

. op

erat

ions

Current Current

15 20 25

Resistive load:

› L/R= 0 ms.

Highly inductive load:

› L/R= 40 ms.

Type A Type B

10000

100000

1000000

10000000

0,00 2,00 4,00 6,00 8,00 10,00 12,00

107

106

105

104

0 2 4 6 8 1210

0 ms 20 ms 40 ms

Vdc Contact configuration P(W) I(A) P(W) I(A) P(W) I(A)

24Type A 500 20,83 370 15,42 250 10,42

Type B 450 18,75 300 12,50 210 8,75

Page 24: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector24

Type A Tiype B

110 Vdc voltage Different loads configurations.

No

. op

erat

ions

No

. op

erat

ions

Current Current

Resistive load:

› L/R= 0 ms.

Highly inductive load:

› L/R= 40 ms.

0 ms 20 ms 40 ms

Vdc Contacts configuration P(W) I(A) P(W) I(A) P(W) I(A)

110Type A 170 1,55 140 1,27 90 0,82

Type B 125 1,14 100 0,91 65 0,59

10000

100000

1000000

10000000

0,00 0,20 0,40 0,60 0,80 1,00 1,20 1,40 1,60 1,80 2,00

107

106

105

104

0,00 0,20 0,40 0,60 0,80 1,00 1,20 1,40 1,60 1,80 2,0010000

100000

1000000

10000000

0,00 0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,80 0,90 1,00

107

106

105

104

0,00 0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,80 0,90 1,00

Page 25: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

25Auxiliary relays | Railway sector

Type A Type B

220 Vdc voltage Different loads configurations.

No

. op

erat

ions

No

. op

erat

ions

Current Current

Resistive load:

› L/R= 0 ms.

Highly inductive load:

› L/R= 40 ms.

0 ms 20 ms 40 ms

Vdc Contacts configuration P(W) I(A) P(W) I(A) P(W) I(A)

220Type A 150 0,68 115 0,52 66 0,30

Type B 125 0,57 104 0,47 60 0,27

0,00 0,10 0,20 0,25 0,30 0,35 0,400,00 0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,8010000

100000

1000000

10000000

0,00 0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,80

107

106

105

104 10000

100000

1000000

10000000

0,00 0,05 0,10 0,15 0,20 0,25 0,30 0,35 0,40

107

106

105

104

0,05 0,15

Page 26: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector26

These charts show the breaking capacity values, either for resistive and highly inductive loads, in three voltage values of reference (ask for other voltage values). The charts show two different curves:

› Type A: Breaking capacity of the relays with distance between contacts = 1.8 mm.

› Type B: Breaking capacity of the relays with distance between contacts = 1.2 mm.

The distance between contacts is shown in the tables of technical data.

ARTECHE’s auxiliary relays are power relays, designed specially to have a high breaking capacity. Thus, there are applications where the loads are so high that it is necessary to even increase the breaking capacity, keeping the reliability of the contacts of the auxiliary relays.

Thus, ARTECHE relays have the following alternatives and recommendations:

› Possibility of external connection of equipment (serial contacts) getting an important increase of breaking capacity in these equipment is shown, guaranteeing the right performance during a high number of operations.

› Include the magnetic blow-out option: This option is indicated for safety applications (back-up) where the load values are extremely high. The mechanical life of the relay is reduced, but it is able to open very high loads for a certain number of operations.

These values of high breaking capacity are represented in the following table, where the high capacity of the output contacts of ARTECHE’s auxiliary relays is proved:

HOW TO SELECT THE CURVE OF MY RELAY

HOW THE BREAKING CAPACITY CAN BE INCREASED

Relay I V L/R

With contact configuration Type A + magnetic blow out (OP: 1XXXX)

5 A 125 Vdc 40 msWith contact configuration Type B + magnetic

blow out (OP: 1XXXX)

Page 27: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Arteche has more than 100 customer service technical points, an expert engineers network close to you everywhere

Page 28: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

28 Auxiliary relays | Railway sector

PICK-UP VOLTAGE/RELEASE VOLTAGE-TEMPERATURE CHARTS

Page 29: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 29

GENERAL PURPOSE RELAYS AND RELAYS WITH COIL OVERVOLTAGE PROTECTION

TRIPPING RELAYS

Temperature (ºC)

U/U

N (

%)

Upper limit of the pick-up voltage

Lower limit of the Pick-up voltage

Lower limit of the Drop-out voltage

Operative range of the coil voltage

Upper limit of the pick-up voltage

Lower limit of the Pick-up voltage

Lower limit of the Drop-out voltage

Operative range of the coil voltage

Temperature (ºC)

Operative range against ambient temperature

Operative range against ambient temperature

Variability of operative voltage range against temperature for the instantaneous auxiliary relays.

200

150

-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130

100

50

0

200

150

-40 -30 -20 -10 0 10 20 30 40 50 60 70

U/U

N (

%)

80

100

50

0

INSTANTANEUS RELAYS

90 100

Page 30: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector30

LATCHING PURPOSE RELAYS AND RELAYS WITH COIL OVERVOLTAGE PROTECTION

Temperature (ºC)

U/U

N (

%)

Operative range against ambient temperature

Variability of operative voltage range against temperature for the Latching relays.

LATCHING RELAYS

Upper limit of the pick-up voltage

Lower limit of the Pick-up voltage

Operative range of the coil voltage

INSTANTANEOUS RELAYS WITH SEISMIC CHARACTERISTICS AND RELAYS WITH SEISMIC CHARACTERISTICS WITH COIL OVERTAGE PROTECTION

Upper limit of the pick-up voltage

Lower limit of the Pick-up voltage

Lower limit of the Drop-out voltage

Operative range of the coil voltage

Operative range against ambient temperature

U/U

N (

%)

Temperature (ºC)

250

200

150

-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130

100

50

0

200

250

150

-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130

100

50

0

Page 31: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 31

Operative range against ambient temperature

Variability of operative voltage range against temperature forthe time-lag relays.

TIME-LAG RELAYS

TRIP AND LOCKOUT RELAY AND TRIP AND LOCKOUT RELAY WITH RESET PUSH BUTTON

Upper limit of the pick-up voltage

Lower limit of the Pick-up voltage

Operative range of the coil voltage

U/U

N (

%)

Temperature (ºC)

* Operative range against ambient temperature

TIME-LAG RELAYS

Upper limit of the pick-up voltage

Lower limit of the Pick-up voltage

Lower limit of the Drop-out voltage

Operative range of the coil voltage

U/U

N (

%)

Temperature (ºC)

* Up to 125 Vdc

200

250

150

-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130

100

50

0

-40 -30 -20 -10 0 10 20 30 40 50 60 70 80

200

150

100

50

090 100

Page 32: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector32

MODELS SELECTIONInstantaneous Type Range Range

FF(*)Aux. SupplyVdc or Vac.

Options

OP

General purpose range

2 contacts relay RD-2

4 contacts relay RF-4 1

8 contacts relay RJ-8 1

Tripping relays range

Fast R 1

Extra-fast (Vdc only) XR 1

Seismic characteristics range

Seismic SY

With coil overvoltage protection range

Diode in parallel with the coil (only Vdc)

DI

Varistance in parallel with the coil V

With seismic characteristics and coil overvoltage

protection range

Seismic with diode in parallel with the coil (only Vdc)

SYDI

Seismic with varistance in parallel with the coil

SYV

Range

No -

Yes FF

Aux. SupplyVdc o Vac

Indicate voltage level and if it is VDC or VAC (ex: 24 VDC)

Options

High breaking capacity (magnetic arc blow-out)

No 0

Yes 1

Front LEDNo 0

Yes 1

Mechanical contact position indicator

No 0

Yes 1

Trip flagNo 0

Yes 1

Push to test button

No 0

To push the contacts 1

Fix the contacts 2

Restrictio

ns

(*) Indicate just if FF range is required

Page 33: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 33

Timers Type RangeFF(**)

Aux. SupplyVdc or Vac.

Options

OP

General purpose range

Relay with 2 timer contactsTDF-2

Relay with 4 timer contactTDF-4

Relay with 2 instantaneous contacts + 2 timer contacts TDF-22

Relay with 8 timer contactsTDJ-8

Relay with 4 instantaneous contacts + 4 timer contacts TDJ-44

Range FF

No -

Yes FF

Aux. Supply Vdc o Vac

Indicate voltage level and if it is VDC or VAC (ex: 24 VDC)

Options

High Breaking Capacity (magnetic arc blow-out)

No 0

Yes 1

Command sign voltage

Dependent 0

Independent

24 Vdc • Vac 1

48 Vdc • Vac 2

60 Vdc • Vac 3

72 Vdc • Vac 4

96 Vdc • Vac 5

110 Vdc • Vac 6

125 Vdc • Vac 7

220 Vdc • Vac 8

Restrictio

ns

Latching Type Range RangeFF(**)

Aux. SupplyVdc or Vac.

General purpose range

3 contacts relay BF-3

4 contacts relay BF-4

8 contacts relay BJ-8

Options

Diode in parallel with the coil (only Vdc)

BB

Trip relay (only Vdc) R

Fast-acting with reset push button (*)

RP

Range FF

No -

Yes FF

Aux. Supply Vdc o Vac

Indicate voltage level and if it is VDC or VAC (ex: 24 VDC)

(*) Indicate just if FF range is required

(*) Unavailable for 3 contacts (**) Indicate just if FF range is required

Page 34: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector34

SOCKETS: DIMENSIONS AND CUT-OUT

DIMENSIONS OF THE RELAYS

50

,4

22,5

72

10,5

50

,4

82,5

72

10,5

50

,4

42,5

72

10,5

F Short J Short

50

,4

82,5

*100,5 96,6

*depending on the model

96,6

10,5

50

,4

42,5

10,5

F Long J Long

Type D Type F Type J

Relay dimensions

Sockets Accessories

Relay Type Screw Double faston Weight (g)

D

TIP10 Front connection DN-DE IP10 FF DN-DE2C IP10 FF 60

IP20 Front connection DN-DE IP20 FF DN-DE2C IP20 FF 60

Rear connection DN-TR OP FF DN-TR2C OP FF 50

F

IP10 Front connection FN-DE IP10 FF FN-DE2C IP10 FF 110

IP20 Front connection FN-DE IP20 FF FN-DE2C IP20 FF 110

IP20 Rear connection FN-TR OP FF FN-TR2C OP FF 90

IP20 Flush mounting F-EMP OP FF 300

J

IP10 Front connection JN-DE IP10 FF JN-DE2C IP10 FF 225

IP20 Front connection JN-DE IP20 FF JN-DE2C IP20 FF 225

IP20 Rear connection JN-TR OP FF JN-TR2C OP FF 180

IP20 Flush mounting J-EMP OP FF 400

Accessories

Retaining clips

Function signs on the extraction ring

Security pins (*)

(*) Not availble for latching relays

Page 35: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

Auxiliary relays | Railway sector 35

FN-DE IP10 FF • FN-DE2C IP10 FF

FN-TR OP FF • FN-TR2C OP FF

F-EMP OP FF • F-EMP (short) OP FF

F-EMP OP FF • F-EMP (long) OP FF

JN-DE IP10 FF • JN-DE2C IP10 FF

JN-TR OP FF • JN-TR2C OP FF

J-EMP OP FF • J-EMP (short) OP FF

J-EMP OP FF • J-EMP (long) OP FF

DN-DE IP10 FF • DN-DE2C IP10 FF

FN-DE IP20 FF • FN-DE2C IP20 FF JN-DE IP20 FF • JN-DE2C IP20 FFDN-DE IP20 FF • DN-DE2C IP20 FF

DN-TR OP FF • DN-TR2C OP FF

2932,3

105

24

22,719,8

286

4

24

21

2043

6

42

42 42

42

112

3129

51,

2

23

51,

2

29

32,3

44

42,739,8 29

31 82,7 312979,8

43

44

40,5 0,2

4043

6

41,

8

48

64

112

112

105

80

88

12,515

15

75 120

5766

6150

4,5

80 min

90

min

R2

12,5

80

51,

2

84 43680

41,

8

8483

88

1064,5

125

90

min5766

96

29

32,3

64

105

Relays type D Relays type F Relays type J

Sockets for flush mounting

Cut-out

Sockets for DIN

rail

Sockets for rear

connection

101,5

101,5

80

75

12,5

15

8

124

80

120

12,5

15

8

124

106

4,5

125

90 min

5766

96

(1) (2)

= =

==

+- 80,5 0,2+

-

Cut-out

Cut-out

Cut-out

(1) DIN rail according to EN50022

DIN46277/3

(2) Minimum distance between sockets will depend on type of relay and

sockets. Please request sockets user manual for more detailed information.

Front connection for double

faston IP10 sockets

DN-DE2C IP10

FN-DE2C IP10

JN-DE2C IP10

lateral connection for the

rest of the sockets

(*) Not availble for latching relays

Page 36: AUXILIARY RELAYS FOR RAILWAY SECTOR. · 2014-09-25 · 4 Auiliar relays | Railway sector ARTECHE auxiliary relays are designed to guarantee the best features and complete security

www.arteche.com ©Arteche

Updates: ARTECHE_CT_Auxiliary-Relays-Railway Sector_EN Version: D1