AvalancheInstallation and Operation Guide

Part #69-2973-062 of Assembly #60-2974-024Copyright 2013. All rights reserved, Teledyne IscoRevision Y, May 2015

http://www.isco.com

Foreword

This instruction manual is designed to help you gain a thorough understanding of the operation ofthe equipment. Teledyne Isco recommends that you read this manual completely before placing theequipment in service.

Although Teledyne Isco designs reliability into all equipment, there is always the possibility of amalfunction. This manual may help in diagnosing and repairing the malfunction.

If a problem persists, call or e-mail Teledyne Isco technical support for assistance. Simple difficul-ties can often be diagnosed over the phone. For faster service, please have your serial numberready.

If it is necessary to return the equipment to the factory for service, please follow the shippinginstructions provided by technical support, including the use of the Return Merchandise Authori-zation (RMA) specified. Be sure to include a note describing the malfunction. This will aid inthe prompt repair and return of the equipment.

Teledyne Isco welcomes suggestions that would improve the information presented in this manualor enhance the operation of the equipment itself.

Teledyne Isco is continually improving its products and reserves the right to change productspecifications, replacement parts, schematics, and instructions without notice.

Contact Information

Customer Service

Phone: (800) 228-4373 (USA, Canada, Mexico)

(402) 464-0231 (Outside North America)

Fax: (402) 465-3022

Email: IscoCSR@teledyne.com

Technical Support

Phone: Toll Free (866) 298-6174 (Samplers, Flow Meters and Multi-parameter Probes)

Toll Free (800) 775-2965 (Syringe Pumps and Liquid Chromatography)

Email: IscoService@teledyne.com

Return equipment to: 4700 Superior Street, Lincoln, NE 68504-1398

Other Correspondence

Mail to: P.O. Box 82531, Lincoln, NE 68501-2531

Email: IscoInfo@teledyne.com

Revised April 2014

Avalanche Portable Refrigerated SamplerSafety

iii

Avalanche Portable Refrigerated SamplerSafety

Avalanche Safety Information

The Isco Avalanche Transportable Sampler is a definitepurpose device, intended for use only with compatible Iscoequipment. Do not use this product with any other manufac-turers equipment, or for any other purpose. Use for any purposenot described in this manual could cause personal injury orproperty damage.

Electrical Requirements The Avalanche requires 12 VDC at 6 amperes. The DC powerinput is through the two-pin connector on the side of the refrig-erated compartment. The Isco-supplied DC connect cablesprovide over-current protection through the use of an in-line 8A,32V fuse. The Avalanche may also be powered by an 87 to 264VAC, 47 to 63 Hz, 2 ampere power source using the attached ACline cord. The AC-powered Avalanche is protected by an internalthermal cut-out. Additionally, the controller circuitry is protectedby an internal 5.0 ampere PTC (Positive Temperature Coeffi-cient) device.

WARNINGElectrocution hazard. Never manipulate electrical switches or power connections with wet hands or when your feet are in contact with water.

WARNINGAC electrical power must meet the applicable electrical code requirements for your installation and must be provided with an earth ground connection. If necessary, consult with a certified electrician to ensure that AC power is provided in accordance with the local electrical code.

AC Powered Avalanches The AC power cord of this device is quipped with a three-pronggrounding plug designed to mate with a grounded power outlet.Grounding minimizes the possibility of electrical shock.

It is the users responsibility to ensure that the AC power sourceis properly grounded. If in doubt, have the outlet checked by aqualified electrician.

If the available AC power outlet only accepts two prongs, or if itis determined that the outlet is improperly grounded, the outletmust be replaced by a qualified electrician before attempting topower this device.

WARNINGNever modify the AC power cord or use a three-prong to two-prong adapter.

WARNINGIf this devices power cord is frayed or otherwise damaged, discontinue its use immediately. The AC power cord is not user-serviceable and must be returned to the factory for repair or replacement.

Avalanche Portable Refrigerated SamplerSafety

iv

General Warnings Before installing, operating, or maintaining this equipment, it isimperative that all hazards and preventive measures are fullyunderstood. While specific hazards may vary according tolocation and application, take heed in the following generalwarnings:

WARNINGThis instrument has not been certified for use in hazardous locations as defined by the National Electrical Code.

WARNINGAvoid hazardous practices! If you use this instrument in any way not specified in this manual, the protection provided by the instrument may be impaired; this will increase your risk of injury.

AVERTISSEMENTviter les usages prilleux! Si vous utilisez cet instrument dune manire autre que celles qui sont specifies dans ce manuel, la protection fournie de linstrument peut tre affaiblie; cela augmentera votre risque de blessure.

Additional safety information can be found in Appendix C.

Hazard Severity Levels This manual applies Hazard Severity Levels to the safety alerts,These three levels are described in the sample alerts below.

CAUTIONCautions identify a potential hazard, which if not avoided, mayresult in minor or moderate injury. This category can also warnyou of unsafe practices, or conditions that may cause propertydamage.

WARNINGWarnings identify a potentially hazardous condition, which if not avoided, could result in death or serious injury.

DANGERDANGER limited to the most extreme situations to identify an imminent hazard, which if not avoided, will result in death or serious injury.

Avalanche Portable Refrigerated SamplerSafety

v

Hazard Symbols The equipment and this manual use symbols used to warn ofhazards. The symbols are explained below.

Hazard Symbols

Warnings and Cautions

The exclamation point within the triangle is a warning sign alerting you of important instructions in the instruments technical reference manual.

The lightning flash and arrowhead within the triangle is a warning sign alert-ing you of dangerous voltage inside the product.

Pinch point. These symbols warn you that your fingers or hands will be seri-ously injured if you place them between the moving parts of the mechanism near these symbols.

Symboles de scurit

Ce symbole signale lexistence dinstructions importantes relatives au produit dans ce manuel.

Ce symbole signale la prsence dun danger dlectocution.

Risque de pincement. Ces symboles vous avertit que les mains ou les doigts seront blesss srieusement si vous les mettez entre les lments en mouvement du mcanisme prs de ces symboles

Warnungen und Vorsichtshinweise

Das Ausrufezeichen in Dreieck ist ein Warnzeichen, das Sie darauf aufmerksam macht, da wichtige Anleitungen zu diesem Handbuch gehren.

Der gepfeilte Blitz im Dreieck ist ein Warnzeichen, das Sei vor gefhrlichen Spannungen im Inneren des Produkts warnt.

Vorsicht Quetschgefahr! Dieses Symbol warnt vor einer unmittelbar drohen-den Verletzungsgefahr fr Finger und Hnde, wenn diese zwischen die beweglichen Teile des gekennzeichneten Gertes geraten.

Advertencias y Precauciones

Esta seal le advierte sobre la importancia de las instrucciones del manual que acompaan a este producto.

Esta seal alerta sobre la presencia de alto voltaje en el interior del pro-ducto.

Punto del machacamiento. Sus dedos o manos seriusly sern daados si usted los coloca entre las piezas mviles cerca de estos smbolos.

Avalanche Portable Refrigerated SamplerSafety

vi

vii

AvalanchePortable Refrigerated Sampler

Table of Contents

Section 1 Introduction

1.1 About this Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11.2 About 700 Series Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21.3 SDI-12 Sondes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21.4 Telephone Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

1.4.1 4200T Landline Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31.4.2 GSM Cellular Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31.4.3 CDMA Cellular Modem for CSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31.4.4 6712Ci Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31.4.5 Software Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

1.5 Memory to Store Monitoring Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-51.6 Pump Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

Section 2 Installation/Preparation

2.1 Receiving Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12.1.1 Case Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Recommended

View more >