avery-hardoll bm series flowmeters

4
BM Series Flowmeters www.lcmeter.com The positive displacement principle is the ONLY accurate method of measuring fluid flow. No other technology can achieve such accuracy because measurement becomes inferred, that is indirect and subject to assumption. The Avery-Hardoll® bulkmeter directly converts volume to rotational output with minimum scope for error and with minimal disturbance from surrounding conditions, eg. turbulence from nearby valves, bends, etc. The product enters the meter through the inlet manifold (1) and causes the rotor (4) to revolve by pressure on the vanes (3). The proximity of the rotor (4) to the body (2) forms an efficient seal, whilst the profile of the casing ensures that the vanes (3) are guided through the measuring crescent (5), where the volume of product is accurately measured. Product at line pressure fills the spaces between the inner (6) and outer (7) end covers providing pressure balanced inner end covers’ which are therefore protected from distortion due to changes in line pressure. An extension shaft driving through a pressure tight gland in the meter front cover, transmits the rotor revolutions to the calibrating gearing (8) which drives the counter (9). Operation BM Series Flowmeters Precision Positive Displacement Bulk Fuel Meters • Positive displacement liquid measuring instruments • Unequalled performance in measurement to 0.1% accuracy. • Free from installation effects • 115 to 3870 LPM (25 to 850 GPM) flow rates Features Avery-Hardoll bulkmeters are precision made positive displacement liquid measuring instruments that maintain accurate metering over long periods of operation. Simplicity of design together with sustained accuracy has led to widespread global use on aviation refuelling vehicles as well as master meters for use in calibration.

Upload: liquid-controls

Post on 25-Jul-2016

292 views

Category:

Documents


4 download

DESCRIPTION

Avery-Hardoll bulkmeters are precision made positive displacement liquid measuring instruments that maintain accurate metering over long periods of operation.

TRANSCRIPT

Page 1: Avery-Hardoll BM Series Flowmeters

BM

Serie

s F

low

mete

rs

www.lcmeter.com

The positive displacement principle is the ONLY accurate method of measuring fluid flow. No other technology can achieve such accuracy because measurement becomes inferred, that is indirect and subject to assumption. The Avery-Hardoll® bulkmeter directly converts volume to rotational output with minimum scope for error and with minimal disturbance from surrounding conditions, eg. turbulence from nearby valves, bends, etc.• The product enters the meter through the inlet manifold (1) and causes the rotor (4) to revolve by

pressure on the vanes (3).• The proximity of the rotor (4) to the body (2) forms an efficient seal, whilst the profile of the

casing ensures that the vanes (3) are guided through the measuring crescent (5), where the volume of product is accurately measured.

• Product at line pressure fills the spaces between the inner (6) and outer (7) end covers providing pressure balanced inner end covers’ which are therefore protected from distortion due to changes in line pressure.

• An extension shaft driving through a pressure tight gland in the meter front cover, transmits the rotor revolutions to the calibrating gearing (8) which drives the counter (9).

Operation

BM Series Flowmeters

Precision Positive Displacement Bulk Fuel Meters

• Positive displacement liquid measuring instruments

• Unequalled performance in measurement to 0.1% accuracy.

• Free from installation effects• 115 to 3870 LPM (25 to 850 GPM) flow rates

Features

Avery-Hardoll bulkmeters are precision made positive displacement liquid measuring instruments that maintain accurate metering over long periods of operation. Simplicity of design together with sustained accuracy has led to widespread global use on aviation refuelling vehicles as well as master meters for use in calibration.

Page 2: Avery-Hardoll BM Series Flowmeters

BM

Seri

es F

low

mete

rs

Key Dimensions

www.lcmeter.com

BM Series Flowmeters

Operational Specifications and Calibration

Maximum working pressure: 10.5 bar (150 psi)

Test pressure: 21 bar (300 psi)

Temperature range: -28ºC to 100ºC

Volume per revolution:• 2.27 litres (single capsule)• 4.54 litres (double capsule)• 6.82 litres (triple capsule)

Repeatability (typically): .02%

Calibration adjustment is provided to minimize the metererroratanyselectedflowrate.Adjustmentis stepless; no gear changing is necessary; the calibrationscrewiseasilyaccessibleafterbreakingasealandremovingasealingscrew.

Allmetersaretestedto300psi(21bar).

Allmetersaretestedbeforedispatchatarangeofflowratesandtestcertificatescanbesuppliedifrequested.

Thefluidusedfortestingisodorlesskerosene.• Specificgravityat60/60ºF,15/15ºC=0.8• Viscosityat60ºF,15ºC=2.4centistokes.

Suggested correction to be made to the calibrating mechanismwhenusedwithproductswithdifferentviscositiesasfollows:• Gasoline + 0.1% (increase counter readings)• Kerosene 0.0% (decrease counter readings)• Gas Oil - 0.1%• FuelOil-0.22%

Typical accuracy curves for the basic meter build (10:1 turndown)

Page 3: Avery-Hardoll BM Series Flowmeters

BM

Serie

s F

low

mete

rs

www.lcmeter.com

Performance

BM Series Flowmeters

Viscous Products

Avery-Hardollbulkmeterscanbeusedonallpetroleumproductsofallviscosities.Howeverthereisobviouslyanincreaseinpressuredropwithmoreviscousfuelswhich,undernormalcircumstances,willlimitthemaximumflowrateobtainable.

Itisrecommendedthatthepressuredropthroughabulkmetershouldnotexceed15psi(onebar),abovewhichtheloadonthebearingswillstarttocausewear.Consequentlywhenusingproductswithviscosities(atoperatingconditions)above100centistokes,itisnecessarytoreducethemaximumpermittedflowrate.Asaguideitissuggestedthatthepressuredropthroughthemetershouldnotexceed10psi(0.7bar)forcontinuousrunningatmaximumspeedor15psi(onebar)forcontinuousrunningathalfspeed.

Pressure Loss

ThelowpressuredropfortheBMseriesofAvery-Hardollbulkmetersisdisplayedbelow:

Page 4: Avery-Hardoll BM Series Flowmeters

BM

Seri

es F

low

mete

rs

Liquid Controls105 Albrecht Dr.

Lake Bluff, IL 60044www.lcmeter.comCopyright © 2015 Liquid Controls, LLCPub. 500000 (10/15) MS275-10

Standard Materials

ManifoldFabricatedsteelorductileironductile iron not available on triple capsule meters

BodyNi-Resist cast iron

Vanes Carbon

Rotor AluminiumorNi-Resistcastiron

Outer CoversAluminiumorNi-Resistcastiron

Inner Covers Ni-Resist cast iron

BearingsStainless steel

Seals Highnitrileorfluorocarbon

Accuracy/Performance

Maximum Working Pressure10.5 bar (150 PSI) Test Pressure21 bar (300 PSI) Temperature Range-28 to 100 ºCRepeatability 0.02% typically

MASTERLOAD II RegisterTheAvery-HardollMASTERLOADII™isaversatilemicroprocessor-based electronic controller. The system is comprisedofapulsetransmitter,displayunit,flowrateand a totaliser.

MASTERLOAD III RegisterTheAvery-HardollMASTERLOADIII™isadualmicroprocessor-basedelectronicmeterregister.Monitorsandreportsover20fuelingdatapointsandiswirelessreportingcapablewithFlightConnect®(option).

CountersStandardVeeder-Rootcounterswithfivelarge-figurezeroingdrumandaseven-figure,smallnon-zeroingtotaliser.

Ticket PrinterAvailablewithorwithoutidentifier,inthefollowingforms:1.Batchdelivery,startingatzeroandshowingtheamountdelivered.2.Accumulativetotalgivinginitialandfinaltotaliserfigures.

Mechanical Preset and Preset ValveAVeeder-Rootpresetregisterwithfive-figureresettablecountercanbeconfiguredtoperformpresetfuellingsviamechanicallinkagetoalever-operatedpresetvalve,providingtwostageclosureandpreciseshutoffofflow.

Slipstream™ DensitometerProvidesreal-timedensitymeasurementoffuelthroughthesystem.(CanbeusedwithMASTERLOADIIIregister)

Volume Per Revolution2.27 litres single capsule4.54 litres double capsule6.82 litres triple capsule

Maximum Flow Rate1370LPM(82m3/hr)single capsule2500LPM(168m3/hr)double capsule - intermittent 3870LPM(232m3/hr)triple capsule

BM Series Flowmeters

Meter Accessories

Mechanical Preset With MicroswitchesMicroswitchescanbefittedtothepresetregistertocontrolpumpstartandstop,andsolenoidoperatedpreset valves.

Rate Of Flow Indicator SwivelExtended Counter DriveProvidedforinstallationswherethecounterisrequiredtobereadatheightabovethebulkmeter.

Counter ExtensionsCounterextensionsareavailabletoarrangethecounteruprightforBMSeriesflowmetersmountedinverticalpipework.

Additive MechanismMechanicallyinjectsfractionalproportionsofadditivesata pre-determined ratio.

StrainerEssentialtopreventdamagetothemeterandisavailablewith40,60,80,100and120meshbaskets,witheithercast iron or cast steel body.

Air SeparatorPrevents entrained air reaching the meter.

Flow GovernorLimitsflowrateatmaximummetercapacitywhenseveralmetersarefedfromonepump.