B i d S e tJ u l y 2 0 1 8
SHOP DRAWINGS OR CONTRACTOR ENGINEERED DETAILS SHALL BEAR THE SEAL AND SIGNATURE
OF A REGISTERED STRUCTURAL ENGINEER IN THE STATE OF OREGON IF IT DIFFERS FROM THE
DESIGN OF THE STRUCTURAL DRAWINGS. ANY REVISION FROM THE STRUCTURAL DRAWINGS SHALL
BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND IS SUBJECT TO THE REVIEW AND ACCEPTANCE
BY THE ENGINEER.
SHOP DRAWINGS FOR ALL STRUCTURAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO
FABRICATION AND CONSTRUCTION. SUCH ITEMS INCLUDE : STRUCTURAL STEEL.
THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS. THE ARCHITECT AND/OR ENGINEER
SHALL BE NOTIFIED OF ANY DISCREPANCY BETWEEN THE EXISTING CONDITIONS AND CONSTRUCTION
DOCUMENTS.
THE CONTRACTOR SHALL TAKE INTO ACCOUNT COLD WEATHER CONSTRUCTION AND THE EFFECTS
OF THERMAL MOVEMENT DURING THE CONSTRUCTION SCHEDULE.
THE STRUCTURAL DRAWINGS ARE INTENDED FOR THE STRUCTURE TO ACT AS A WHOLE ONCE
CONSTRUCTION IS COMPLETE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE SAFETY
AND STABILITY (I.E. TEMPORARY BRACING IF REQUIRED) DURING CONSTRUCTION AS A RESULT OF
CONSTRUCTION METHODS AND SEQUENCES.
THE GENERAL STRUCTURAL NOTES ARE INTENDED FOR USE IN CONJUNCTION WITH THE PROJECT
SPECIFICATIONS. IN THE EVENT OF A CONFLICT BETWEEN THE TWO, THE GENERAL STRUCTURAL NOTES
SHALL SUPERSEDE THE PROJECT SPECIFICATIONS. ANY DISCREPANCY SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT AND ENGINEER.
THE STRUCTURAL DRAWINGS SHALL BE UTILIZED IN CONJUNCTION WITH OTHER DESIGN CONSULTANT'S
DRAWINGS (ARCHITECTURAL, MECHANICAL, ETC.). IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
COORDINATE THE REQUIREMENTS OF THE DRAWINGS INTO THEIR SHOP DRAWINGS AND
CONSTRUCTION.
ALL CONSTRUCTION SHALL CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE AS AMENDED BY THE
STATE OF OREGON.
GENERAL NOTES:
SUBMITTALS:
CONSTRUCTION SEQUENCE AND METHODS:
B.
A.
5.
6.
B.
A.
4.
3.
2.
1.
25 PSF (PLUS ADDED SNOW DRIFT IF SHOWN ON PLANS)
LOADS AND DESIGN CRITERIA: THE FOLLOWING LIVE LOADS AND CRITERIA WERE USED IN ADDITION
TO THE DEAD LOAD OF THE STRUCTURE.
CODE: ASCE 41-13: SEISMIC EVALUATION AND RETROFIT OF EXISTING BUILDINGS.
SEISMIC BRACING AND RESTRAINT TO THE STRUCTURE OF ANY MEP EQUIPMENT, MACHINERY, AND
ASSOCIATED PIPING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONNECTIONS NOT IN
COMPLIANCE WITH SMACNA (SHEET METAL AND AIR CONDITIONING CONTRACTOR'S NATIONAL
ASSOCIATION) OR THE MEP DESIGN DRAWINGS, SHALL BEAR THE SEAL OF REGISTERED ENGINEER
IN THE STATE OF OREGON AND SHALL BE SUBMITTED ALONG WITH CALCULATIONS TO THE
ARCHITECT FOR APPROVAL PRIOR TO FABRICATION.
ASCE 41-13 VOLUNTARY SEISMIC RETROFIT OF SELECT BUILDING ELEMENTS:
LIVE LOADS:
DESIGN CRITERIA:
PERFORMANCE OBJECTIVE: BASIC PERFORMANCE OBJECTIVE FOR EXISTING BUILDINGS (BPOE)
RISK CATEGORY: III
HAZARD LEVEL: BSE - 1E
STRUCTURAL PERFORMANCE LEVEL: LIFE SAFETY
SITE CLASS D
Sxs = 0.55g Sx = 0.336g
ROOF.................................................
7.
A.
B.
WHERE THE AUTHORITY HAVING JURISDICTION OVER THIS PROJECT REQUIRES ADHERENCE TO ACI
318-11 SECTION D.9.2.2, MANUFACTURER'S FIELD REPRESENTATIVE SHALL PROVIDE INSTALLATION
TRAINING FOR ALL PRODUCTS TO BE USED PRIOR TO THE COMMENCEMENT OF WORK. ONLY
TRAINED INSTALLERS SHALL PERFORM POST INSTALLED ANCHOR INSTALLATION. A RECORD OF
TRAINING SHALL BE KEPT ON SITE AND BE MADE AVAILABLE TO THE ENGINEER OF RECORD AS
REQUIRED.
WHERE THE AUTHORITY HAVING JURISDICTION OVER THIS PROJECT REQUIRES ADHERENCE TO THE
ACI 318-11, SECTION D.9.2.2 INSTALLATION OF ADHESIVE ANCHORS IN HORIZONTAL TO VERTICALLY
OVERHEAD ORIENTATION SHALL BE DONE BY A CERTIFIED ADHESIVE ANCHOR INSTALL (AAI) AS
CERTIFIED THROUGH ACI AND IN ACCORDANCE WITH ACI 318-2011 (SECTION D.9.2.2). PROOF OF
CURRENT CERTIFICATION SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO
COMMENCEMENT OF INSTALLATION.
POST-INSTALLED CONCRETE ANCHORS8.
A.
2x AND 3x MEMBERS
4x MEMBERS
6x MEMBERS
I-JOIST MEMBERS
GLU-LAM MEMBERS
2x AND 4x FRAMING
5x AND GREATER BEAMS
POSTS/ COLUMNS
CUTTING AND NOTCHING OF JOISTS, RAFTERS AND STUDS SHALL BE IN CONFORMANCE WITH BOTH THE
2014 OSSC SECTIONS 2308.8.2,
2308.9.10,
2308.9.11,
AND
2308.10.4.2 AND IN CONFORMANCE WITH THE
FOLLOWING CRITERIA:
ALL WALLS SHALL HAVE DOUBLE TOP PLATES AND SHALL BE SPLICED PER THE TYPICAL TOP PLATE
SPLICE DETAIL, UNLESS NOTED OTHERWISE. TOP PLATES AT WALL INTERSECTIONS SHALL BE LAPPED
AND NAILED WITH (3) 16d NAILS.
HOLES FOR BOLTS SHALL BE DRILLED WITH A BIT OF THE SAME NOMINAL DIAMETER AS THE BOLT + 1/16".
ALL BOLTS, CARRIAGE BOLTS, LAG SCREWS, EXPANSION BOLTS AND EPOXY BOLTS SHALL BE INSTALLED
WITH STANDARD CUT WASHERS UNDER THE BOLT HEADS AND NUTS THAT BEAR DIRECTLY ON THE
WOOD. ALL NUTS SHALL BE TIGHTENED AT THE TIME OF INSTALLATION AND RE-TIGHTENED IF
NECESSARY, DUE TO WOOD SHRINKAGE, PRIOR TO CLOSE-IN OR AT THE COMPLETION OF THE PROJECT.
BOLTS AND LAG SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.2.1-1996.
WHERE FRAMING HANGERS ARE REQUIRED BUT ARE NOT SPECIFICALLY SIZED, THE FOLLOWING SIZES
SHALL BE USED. SLOPE, SKEW, TURN IN FLANGES AND PROVIDE TOP FLANGE HANGERS AS REQUIRED
FOR THE SPECIFIC CONDITIONS AT THE END OF THE MEMBER.
ALL METAL HARDWARE AND FRAMING ACCESSORIES SHALL BE MANUFACTURED BY SIMPSON
STRONG-TIE COMPANY. ALL ITEMS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION
REQUIREMENTS. ALL NAIL HOLES SHALL BE FILLED WITH THE RECOMMENDED FASTENER UNLESS NOTED
OTHERWISE ON THE DRAWINGS.
ALL LUMBER IN CONTACT WITH THE GROUND, CONCRETE OR CMU SHALL BE PRESSURE TREATED.
CONTRACTOR MAY SUBMIT FOR APPROVAL, A MOISTURE BARRIER IN-LIEU OF THE PRESSURE TREATED
WOOD.
ALL SAWN LUMBER SHALL CONFORM TO THE WESTERN WOOD PRODUCTS ASSOCIATION OR THE WEST
COAST LUMBER INSPECTION BUREAU GRADING RULES. LUMBER SHALL BE OF THE SPECIES AND GRADE
SHOWN BELOW:
10.
11.
13.
12.
14.
MEMBER
SAWN LUMBER:
9.
6.
2.
MEMBER
HANGER
U TYPE HANGERS
HU TYPE HANGERS
HUTF TYPE HANGERS
MIT HANGERS
LEG HANGERS
GRADE
DOUGLAS FIR-LARCH NO. 2
DOUGLAS FIR-LARCH NO. 1
DOUGLAS FIR-LARCH NO. 1
LEAD HOLES FOR LAG SCREWS SHALL BE BORED PER NDS 11.1.3
7. FASTENERS FOR PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE OF
HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE, OR COPPER.
FASTENINGS FOR WOOD FOUNDATIONS SHALL BE AS REQUIRED IN AF&PA TECHNICAL REPORT NO. 7.
STORAGE OF ALL LUMBER AND TIMBER ON SITE SHALL BE KEPT OFF GROUND, UNDER COVER AND
PROTECTED FROM DAMAGE.
3.
ALL DIMENSIONAL LUMBER SHALL BE CERTIFIED BY THE SUPPLIER IN WRITING TO BE KILN DRIED.4.
ALL TIMBER SHALL BE CERTIFIED BY THE SUPPLIER IN WRITING TO BE LESS THAN 19% MOISTURE
CONTENT.
5.
ALL PLATES AND LEDGERS SHALL BE FASTENED WITH A MINIMUM (3) ANCHORS PER PIECE.8.
NOTCHES AT THE ENDS OF JOISTS SHAL NOT EXCEED 1/4 THE JOIST DEPTH. HOLES
BORED IN JOISTS SHALL NOT BE WIHTIN 2 INCHES OF THE TOP OR BOTTOM OF THE
JOIST, AND THE DIAMETER OF ANY SUCH HOLE SHALL NOT EXCEED 1/3 THE DEPTH
OF THE JOIST. NOTCHES IN THE TOP OR BOTTOM OF THE JOISTS SHALL NOT
EXCEED 1/6 THE DEPTH AND SHALL NOT BE LOCATED IN THE MIDDLE THIRD OF THE
SPAN.
STUDS ARE PERMITTED TO BE CUT OR NOTCHED TO A MAXIMUM DEPTH NOT
EXCEEDING 25% OF ITS WIDTH. A HOLE NOT GREATER THAN 40% OF THE STUD WITH
IS PERMITTED TO BE BORED IN ANY WOOD STUD. IN NO CASE SHALL THE EDGE OF
THE BORED HOLE BE NEARER THAN 5/8 INCH TO THE EDGE OF THE STUD. BORED
HOLES SHALL NOT BE LOCATED AT THE SAME SECTION AS A CUT OR NOTCH.
NOTCHING AT THE ENDS OF RAFTERS OR CEILING JOISTS SHALL NOT EXCEED 1/4
THE DEPTH. NOTCHES IN THE TOP OR BOTTOM OF THE RAFTER OR CEILING JOIST
SHALL NOT EXCEED 1/6 THE DEPTH AND SHALL NOT BE LOCATED IN THE MIDDLE 1/3
OF THE SPAN, EXCEPT THAT A NOTCH NOT EXCEEDING 1/3 OF THE DPETH IS
PERMITTED IN THE TOP OF THE RAFTER OR CEILING JOIST NOT FURTHER FROM THE
FACE OF THE SUPPORT THAN THE DEPTH OF THE MEMBER. HOLES BORED IN
RAFTERS OR CEILING JOISTS SHALL NOT BE WITHIN 2 INCHES OF THE TOP AND
BOTTOM AND THEIR DIAMETER SHALL NOT EXCEED 1/3 THE DEPTH OF THE MEMBER.
B. JOISTS
C. WALL STUDS
D. RAFTERS
ALL WOOD FRAMING MEMBERS INCLUDING BUT NOT LIMITED TO WALL STUDS AND JOISTS, ARE
INTENDED TO ACT AS A SYSTEM AS DETAILED IN THE STRUCTURAL DRAWINGS AND ONCE
CONSTRUCTION IS COMPLETE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE SAFETY
AND STABILITY OF WOOD FRAMING SYSTEMS (I.E. TEMPORARY BRACING IF REQUIRED) DURING
CONSTRUCTION AS A RESULT OF CONSTRUCTION METHODS AND SEQUENCES.
1.
GENERAL STRUCTURAL NOTES
WELDS SHALL UTILIZE E70XX ELECTRODES AND SHALL BE A MINIMUM OF 3/16" IN SIZE UNLESS NOTED
OTHERWISE.
WELDING SHALL CONFORM TO THE AWS CODES FOR BUILDING CONSTRUCTION. WELDING SHALL BE
PERFORMED IN ACCORDANCE WITH A WELDING PROCEDURE SPECIFICATION (WPS) AS REQUIRED IN AWS
D1.1 AND APPROVED BY THE ENGINEER OF RECORD. THE WPS VARIABLES SHALL BE WITHIN THE
PARAMETERS ESTABLISHED BY THE FILLER-METAL MANUFACTURER.
BOLTS SHALL CONFORM TO ASTM SPECIFICATIONS FOR A307 BOLTS.
STEEL DESIGN, FABRICATION, AND ERECTION SHALL CONFORM WITH "AISC SPECIFICATION FOR THE
DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" AND THE "CODE OF
STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES".
THE GRADE AND SPECIFICATION OF THE STEEL MEMBERS SHALL BE AS FOLLOWS:
HOLLOW STRUCTURAL SECTIONS (PIPES)
HOLLOW STRUCTURAL SECTIONS (TUBES)
CHANNELS, PLATES, AND ANGLES (U.N.O.)
4.
5.
3.
STRUCTURAL STEEL:
2.
1.
ASTM A53 GRADE B (Fy=35 KSI)
ASTM A500 GRADE B (Fy=46 KSI)
ASTM A36
CUTTING AND NOTCHING OF EXISTING JOISTS, RAFTERS, AND STUDS IS NOT
ALLOWED WITHOUT WRITTEN ACCEPTANCE FROM ABHT STRUCTURAL ENGINEERS.
A. JOISTS, STUDS,
RAFTERS
WOOD SYMBOLS:15.
ALL NAILS FOR STRUCTURAL WORK SHALL BE COMMON WIRE NAILS UNLESS NOTED OR DETAILED
OTHERWISE. HOLES SHALL BE PRE-DRILLED WHERE NECESSARY TO PREVENT SPLITTING. NAILING NOT
SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE PER THE NAILING SCHEDULE BELOW:
16.
NAIL TYPE
6d
8d
10d
12d
16d
20d
CONTINUOUS
MINIMUM PENETRATION - INCHES
BLOCKING
0.113
0.131
0.148
0.148
0.162
0.192
SHANK DIAMETER - INCHES
NAILING SCHEDULE
1.13
1.31
1.48
1.48
1.63
1.92
NAILING SCHEDULE NOTES:
1. ALL OTHER NAILING REQUIREMENTS NOT SHOWN ON DRAWINGS OR IN SCHEDULE ABOVE SHALL BE IN
ACCORDANCE WITH 2012 IBC TABLE 2304.9.1.
2. POWER DRIVEN OR PNUEMATIC NAILS OTHER THAN COMMON NAILS MAY BE USED IF DATA IS SUBMITTED
TO THE ARCHITECT/ENGINEER FOR APPROVAL PRIOR TO USE.
3. MINIMUM NAIL LENGTHS SHALL BE SUFFICIENT TO ACHIEVE MINIMUM PENETRATION INTO MAIN MEMBER
AS NOTED IN SCHEDULE ABOVE.
DOUBLE TOP PLATES - BETWEEN SPLICE NAILING..............................
DOUBLE TOP PLATES - EACH SIDE OF SPLICED PLATE.......................
JOIST SITTING ON SILL OR GIRDER........................................................
RIM JOIST TO TOP PLATE OR SILL PLATE...............................................
CONTINUOUS (2) AND (3) PIECE HEADERS.............................................
CEILING JOIST LAPS OVER PARTITIONS.................................................
RAFTER TO TOP PLATE OR SILL PLATE..................................................
TONGUE AND GROOVE DECKING............................................................
D. STUD TO SILL PLATE.................................................................................
DOUBLE STUDS..........................................................................................
BLOCKING TO TOP PLATE.........................................................................
BUILT-UP CORNER STUDS........................................................................
CROSS BRIDGING.......................................................................................P.
I.
J.
M.
N.
L.
K.
F.
G.
H.
E.
BRIDGING TO JOIST...................................................................................
TOP PLATE TO STUD.................................................................................
B.
C.
A. (3) 8d TOENAILS, EA. SIDE
(2) 8d TOENAILS, EA. SIDE, EA. END
16d AT 16" o.c. FACE NAILS
16d AT 24" o.c.
16d AT 24" o.c.
(3) 8d TOE NAILS EACH SIDE
8d TOENAILS AT 6" o.c.
16d AT 16" o.c. ALONG EACH EDGE
(3) 16d FACE NAILS, MINIMUM
(3) 8d TOENAILS EACH SIDE
(2) 16d AT EACH BEARING
(2) 10d EACH END
(2) 16d END NAILS OR (4) 8d TOE NAILS
(8) 16d
(2) 16d END NAILS
SAWN LUMBER CONTINUED:
COMPOSITE WOODS SHALL BE MANUFACTURED BY TRUSS JOIST, OR AN APPROVED EQUAL,
COMPOSITE WOODS:
AND BE OF THE TYPE AND SIZE AS SHOWN ON THE DRAWINGS. THE MATERIAL TYPE AND
COMPOSITE WOOD BEAM SYMBOLS:
COMPOSITE MEMBER
4.
1.
LSL
LVL
PSL
TYPE
E = 1,700,000 PSI, Fb = 2,600 PSI
E = 1,900,000 PSI, Fb = 2,600 PSI
E = 2,000,000 PSI, Fb = 2,900 PSI
GRADE
LSL
PSL
TYPE
E = 1,300,000 PSI, Fb = 1,700 PSI, FcII = 1,400 PSI
E = 1,800,000 PSI, Fb = 2,400 PSI, FcII = 2,500 PSI
GRADE
A. BEAMS:
B. POSTS:
WHERE LSL MEMBERS ARE UTILIZED AS RIM JOIST, THE MINIMUM THICKNESS SHALL BE 1 3/4"5.
GRADE SHALL BE AS SHOWN BELOW:
STRUCTURAL COMPOSITE LUMBER SHALL BE MANUFACTURED IN ACCORDANCE WITH ASTM D5456.2.
CUTS, NOTCHES AND BORED HOLES SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS.3.
1
PROJECT SUMMARY:
THE CURRENT PROJECT CONSISTS OF A VOLUNTARY SEISMIC UPGRADE OF SELECT ELEMENTS OF
THE OVERALL BUILDING. ELEMENTS UPGRADED INCLUDE:
INTERIOR AND END WALL OUT-OF-PLANE BRACING OF THE MAIN EAST-WEST CORRIDOR WALLS.
OUT-OF-PLANE PARAPET WALL BRACING OVER THE MAIN NORTH ENTRY.
1.
2.
THE EXISTING BUILDING'S PRIMARY LATERAL FORCE RESISTING SYSTEM CONSISTS OF EXTERIOR
UN-REINFORCED MASONRY SHEAR WALLS ON CONTINUOUS CONCRETE SPREAD FOOTINGS AND A
FLEXIBLE ROOF DIAPHRAGM CONSISTING OF 1x6 STRAIGHT SHEATHING OVER A WOOD FRAMED ROOF.
THE REMAINING KNOWN PRIMARY LATERAL FORCE RESISTING SYSTEM DEFICIENCIES INCLUDE:
LACK OF OUT-OF-PLANE ANCHORAGE OF UN-REINFORCED MASONRY WALLS TO ROOF DIAPHRAGM.
EXISTING WOOD LEDGERS ACT IN CROSS GRAIN BENDING.
LACK OF ADEQUATE CONNECTIONS TO TRANSFER IN-PLANE SEISMIC FORCES FROM ROOF DIAPHRAGM TO
SHEAR WALLS.
LACK OF CONTINUOUS CROSS TIES TO FORM ADEQUATE SUB-DIAPHRAGMS.
DIAPHRAGM ASPECT RATIOS EXCEED LIMITS ALLOWED FOR STRAIGHT SHEATHED DIAPHRAGMS.
LACK OF SECONDARY GRAVITY SUPPORT SYSTEM BENEATH CRITICAL GRAVITY LOAD CARRYING ELEMENTS.
LACK OF COLLECTORS TO TRANSFER DIAPHRAGM LOADS TO SHEARWALLS.
UN-REINFORCED MASONRY WALLS LACK OUT-OF PLANE STRENGTH.
LACK OF PARAPET AND CHIMNEY BRACING.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Po
rtla
nd
Pa
rks
an
d R
ecr
ea
tio
n
REVISIONSDATE BYDESCRIPTION
SE
CT
ION
:D
RA
WN
BY
:D
AT
E:
PR
OJE
CT
MA
NA
GE
R:
MA
RLO
ME
DE
LLIN
SC
ALE
:
$FI
LE$
$D
AT
E$
PLO
TT
ED
ON
:D
RA
WIN
G:
NOTE:SCALE INDICATED ON DRAWINGIS CORRECT IF DRAWINGBORDER IS 22" X 34".
PLO
TT
ED
BY
:$
US
ER
NA
ME
$P
LOT
TE
D F
RO
M:
$C
OM
PU
TE
RN
AM
E$
Am
an
da
F
ritz
,
C
om
mis
sio
ne
r
-
Mik
e A
bb
até
,
Dir
ect
or
Mu
ltn
om
ah
Art
s C
en
ter
Vo
lun
tary
Se
ism
ic U
pg
rad
e
B
ID S
ET
76
88
SW
Ca
pit
ol
Hig
hw
ay
P
ort
lan
d,
Ore
go
n
architecture, interiors & planning
419 SW 11th Ave Suite 200
Portland, Oregon 97205
Phone: 503/228-7571
Fax: 503/273-8891
Portland, Oregon 97209
1640 NW Johnson Street
Phone: 503 243 6682
JULY
20
18
SC
S0.1
GENERAL STRUCTURALNOTES
N.T
.S.
TABLE 1
REQUIRED STRUCTURAL SPECIAL INSPECTIONS
SYSTEM or MATERIAL
INSPECTION
REMARKSIBC CODE
REFERENCE
CODE or STANDARD
REFERENCE
FREQUENCY
Continuous Periodic
FABRICATORS
FABRICATORS 1704.2 X
SPECIAL INSPECTIONS APPLY TO VERIFICATION OF DETAILED
FABRICATION AND QUALITY CONTROL PROCEDURES
INCLUDING REVIEW FOR COMPLETENESS AND ADEQUACY
RELATIVE TO THE CODE REQUIREMENTS
STEEL
FABRICATION OF STRUCTURAL ELEMENTS 1704.2 X REFER TO INSPECTION OF FABRICATOR REQUIREMENTS
MATERIAL VERIFICATION OF STRUCTURAL
STEEL
1705.2
2203.1
ASTM A6
ASTM STANDARDS
SPECIFIED IN
CONSTRUCTION
DOCUMENTS
AISC 360 A3.1
AISC 360 M5.5
X CERTIFIED MILL TEST REPORTS
MATERIAL VERIFICATION OF ANCHOR BOLTS
AND THREADED RODS1705.2
AISC 360 A3.4
ASTM STANDARDS
SPECIFIED IN
CONSTRUCTION
DOCUMENTS
X MANUFACTURER'S CERTIFIED TEST REPORTS
MATERIAL VERIFICATION OF WELD FILLER
METALS1705.2
AISC 360 A3.5
APPLICABLE AWS A5
DOCUMENTS
X MANUFACTURER'S CERTIFIED TEST REPORTS
VERIFYING USE OF PROPER WPS'S X COPY OF WELDING PROCEDURE SPECIFICATIONS
VERIFYING WELDER QUALIFICATIONS X COPY OF QUALIFICATION CARDS
COMPLETE AND PARTIAL JOINT PENETRATION
GROOVE WELDS1705.2
AWS D1.1
SECTION 6X
ALL WELDS VISUALLY INSPECTED PER AWS D1.1 6.9TABLE
1705.2AWS D1.1, SECTION 6
SINGLE PASS FILLET WELDS LESS THAN OR
EQUAL TO 5/16"X
SPECIAL INSPECTION TABLE
POST INSTALLED CONCRETE ANCHORS
INSPECTION OF ANCHORS INSTALLED IN
HARDENED CONCRETE1909.1
ICC EVALUATION
REPORT
ACI 318:
3.8.6, 8.1.3, 21.1.8
X
SPECIAL INSPECTIONS APPLY TO ANCHOR PRODUCT NAME,
TYPE, AND DIMENSIONS, HOLE DIMENSIONS, COMPLIANCE
WITH DRILL BIT REQUIREMENTS, CLEANLINESS OF THE HOLE
AND ANCHOR, ADHESIVE EXPIRATION DATE,
ANCHOR/ADHESIVE INSTALLATION, ANCHOR EMBEDMENT, AND
TIGHTENING TORQUE
STEEL
MAGNETIC PARTICLE (MT) AND ULTRASONIC (UT)
TESTING OF WELDS1705.2
MT - AWS D1.1 6.14.4
UT - AWS D1.1 6.13 & 6.14.3PER DRAWINGS
TABLE 2
REQUIRED TESTING for SPECIAL INSPECTIONS
SYSTEM or MATERIAL
TESTING
REMARKSIBC CODE
REFERENCE
CODE or STANDARD
REFERENCE
FREQUENCY
Continuous Periodic
TABLE 3
STRUCTURAL OBSERVATIONS
SYSTEM or MATERIAL
INSPECTION
REMARKSIBC CODE
REFERENCE
CODE or STANDARD
REFERENCE
FREQUENCY
Continuous Periodic
STEEL
DURING MISCELLANEOUS STEEL ERECTION 1704.5 X
SPECIAL INSPECTION FOOTNOTES
STRUCTURAL OBSERVATION:
SPECIAL INSPECTIONS SHALL CONFORM TO CHAPTER 17 OF THE 2012 "INTERNATIONAL BUILDING CODE" AND OREGON AMENDMENTS. REFER TO THE TABLES 1 THROUGH 3
FOR SPECIAL INSPECTION AND TESTING REQUIREMENTS.
SPECIAL INSPECTIONS AND ASSOCIATED TESTING SHALL BE PERFORMED BY AN APPROVED ACCREDITED INDEPENDENT AGENCY MEETING THE REQUIREMENTS OF ASTM
E329 (MATERIALS), ASTM D3740 (SOILS), ASTM A880 (STEEL), AND ASTM E543 (NON-DESTRUCTIVE). THE INSPECTION AND TESTING AGENCY SHALL FURNISH TO THE
STRUCTURAL ENGINEER A COPY OF THEIR SCOPE OF ACCREDITATION. SPECIAL INSPECTORS SHALL BE CERTIFIED BY THE BUILDING OFFICIAL. WELDING INSPECTORS SHALL
BE QUALIFIED PER SECTION 6.1.4.1.1 OF AWS D1.1. THE OWNER SHALL SECURE AND PAY FOR SERVICES OF THE INSPECTION AND TESTING AGENCY TO PERFORM ALL
SPECIAL INSPECTIONS AND TESTS.
THE SPECIAL INSPECTOR SHALL OBSERVE THE INDICATED WORK FOR COMPLIANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. ALL DISCREPANCIES SHALL BE
BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, NOTED IN THE INSPECTION REPORTS, AND IF NOT CORRECTED, THEY SHALL BE BROUGHT
TO THE ATTENTION OF THE STRUCTURAL ENGINEER AND THE BUILDING OFFICIAL.
THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS FOR EACH INSPECTION TO THE BUILDING OFFICIAL, STRUCTURAL ENGINEER, CONTRACTOR, AND OWNER.
THE SPECIAL INSPECTION AGENCY SHALL SUBMIT A FINAL REPORT INDICATING THE WORK REQUIRING SPECIAL INSPECTION WAS INSPECTED AND IS IN CONFORMANCE WITH
THE APPROVED CONSTRUCTION DOCUMENTS AND THAT ALL DISCREPANCIES NOTED IN THE INSPECTION REPORTS HAVE BEEN CORRECTED.
THE STRUCTURAL ENGINEER OF RECORD WILL PERFORM STRUCTURAL SITE OBSERVATIONS BASED ON THE REQUIREMENTS OF THE 2014 OREGON STRUCTURAL SPECIALTY
CODE (OSSC) AND AT CRITICAL STAGES OF CONSTRUCTION, REFERENCE TABLE 3 ABOVE. COPIES OF SITE OBSERVATION REPORTS AND FINAL OBSERVATION REPORT WILL BE
SUBMITTED TO THE BUILDING OFFICIAL, ARCHITECT, CONTRACTOR AND OWNER. THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF RECORD AT LEAST
72-HOURS BEFORE A DESIGNATED WORK IS TO BE COVERED.
ALL C.J.P. WELDS 5/16" AND THICKER REQUIRE
UT TESTING
Po
rtla
nd
Pa
rks
an
d R
ecr
ea
tio
n
REVISIONSDATE BYDESCRIPTION
SE
CT
ION
:D
RA
WN
BY
:D
AT
E:
PR
OJE
CT
MA
NA
GE
R:
MA
RLO
ME
DE
LLIN
SC
ALE
:
$FI
LE$
$D
AT
E$
PLO
TT
ED
ON
:D
RA
WIN
G:
NOTE:SCALE INDICATED ON DRAWINGIS CORRECT IF DRAWINGBORDER IS 22" X 34".
PLO
TT
ED
BY
:$
US
ER
NA
ME
$P
LOT
TE
D F
RO
M:
$C
OM
PU
TE
RN
AM
E$
Am
an
da
F
ritz
,
C
om
mis
sio
ne
r
-
Mik
e A
bb
até
,
Dir
ect
or
Mu
ltn
om
ah
Art
s C
en
ter
Vo
lun
tary
Se
ism
ic U
pg
rad
e
B
ID S
ET
76
88
SW
Ca
pit
ol
Hig
hw
ay
P
ort
lan
d,
Ore
go
n
architecture, interiors & planning
419 SW 11th Ave Suite 200
Portland, Oregon 97205
Phone: 503/228-7571
Fax: 503/273-8891
Portland, Oregon 97209
1640 NW Johnson Street
Phone: 503 243 6682
JULY
20
18
SC
N.T
.S.
S0.2
SPECIAL INSPECTIONPROGRAM
1
S2.1
STRUCTURAL FLOOR PLANSCALE: 1/16" = 1'-0"
5'-0"
PR
OP
OS
ED
EX
TE
NT
S
OF
3/S
5.1
5'-0"
PR
OP
OS
ED
EX
TE
NT
S
OF
3/S
5.1
5'-0"
PR
OP
OS
ED
EX
TE
NT
S
OF
UP
PE
R
PO
RT
ION
OF
2/S
5.1
5'-0"
EX
TE
NT
S
OF
UP
PE
R
PO
RT
ION
OF
2/S
5.1
TYP.
TYP.
TYP.
TYP.
ABOVE
HS
S10
x10x
3/8
TY
P. (
4) P
LAC
ES
1
S5.1
4
S5.1
TYP.
5
S5.1
1
S5.2
1
S5.2TYP.
1
S5.2
1
S5.2
3
S5.1
2
S5.12
S5.1
Po
rtla
nd
Pa
rks
an
d R
ecr
ea
tio
n
REVISIONSDATE BYDESCRIPTION
SE
CT
ION
:D
RA
WN
BY
:D
AT
E:
PR
OJE
CT
MA
NA
GE
R:
MA
RLO
ME
DE
LLIN
SC
ALE
:
$FI
LE$
$D
AT
E$
PLO
TT
ED
ON
:D
RA
WIN
G:
NOTE:SCALE INDICATED ON DRAWINGIS CORRECT IF DRAWINGBORDER IS 22" X 34".
PLO
TT
ED
BY
:$
US
ER
NA
ME
$P
LOT
TE
D F
RO
M:
$C
OM
PU
TE
RN
AM
E$
Am
an
da
F
ritz
,
C
om
mis
sio
ne
r
-
Mik
e A
bb
até
,
Dir
ect
or
Mu
ltn
om
ah
Art
s C
en
ter
Vo
lun
tary
Se
ism
ic U
pg
rad
e
B
ID S
ET
76
88
SW
Ca
pit
ol
Hig
hw
ay
P
ort
lan
d,
Ore
go
n
architecture, interiors & planning
419 SW 11th Ave Suite 200
Portland, Oregon 97205
Phone: 503/228-7571
Fax: 503/273-8891
Portland, Oregon 97209
1640 NW Johnson Street
Phone: 503 243 6682
JULY
20
18
SC
S2.1
STRUCTURAL FLOORPLAN
MASONRY PARAPET BRACING1/2"=1'-0"1
(E) CEILING JOIST
(E) ROOF JOIST
(E) INTERIOR URM
WALL AT MAIN
ENTRANCE
SISTER (2) LVL1 3/4x5 1/2
w/ SIMPSON SDWS22300
@ 6" o.c., STAGGERED
L5x5x3/8 x REQ'D
LENGTH A36
KICKER WITH (5)
SIMPSON
SDS25112 TYP.
(E) WALL STUDS
(E) ROOF RAFTER
(E) ROOF DECK
SIMPSON HGA10 AT RAFTER
AND TOP OF (E) STUD @
COMPRESSION STRUT TYP.
(2) SIMPSON SDWS22500
SCREW THRU SOLE PLATE
AT EA. COMPRESSION
STRUT
MASONRY WALL BRACING1"=1'-0"2
(E) CONCRETE BEAM
(E) LATH & PLASTER CORRIDOR WALL STUDS
(E) FLOOR JOISTS
(E) WALL DOUBLE TOP PLATE
(E) BLOCKING BETWEEN
FLOOR JOISTS
(E) CRIPPLE WALL STUDS
(E) SOLE PLATE
SIMPSON HDU8 AT EA. CORRIDOR WALL w/
7/8"Ø HAS ROD w/ HILTI HIT-RE 500-V3 w/ 10 1/2"
EMBEDMENT DEPTH, TYP.
DO NOT DAMAGE (E) REBAR DURING DRILLING
SIMPSON HTT4 @ 2'-0" o.c.
w/ 3/4"Ø ANCHOR, TYP.
ADD 4x BLOCKING BETWEEN (E) ROOF JOISTS
TO ALIGN WITH HOLDOWN, ATTACH TO EA.
JOIST w/ SIMPSON A35 CLIP (NOT SHOWN), TYP.
BLOCK (4) BAYS, MIN.
(E) ROOF JOISTS
(E) ROOF DECK
(E) PARAPET EXTENDS
ABOVE THE ROOF LINE
MSTD4 MARRIAGE STRAP
CMSTC16 STRAP. EXTEND TO END OF
BLOCKING
(2) A35 CLIPS w/ #6 x 1/2" SPA X SCREWS @ EA.
BLOCKING, TYP. (1) ON EA. SIDE
ROOF FRAMING ABOVE ENTRY1/2"=1'-0"
(E) ROOF DECK
(E) CONCRETE HEADER
OPENING BELOW
L4x4x1/4 x REQ'D LENGTH A36 w/ (1)
3/4"Ø A307 THRU- BOLT, CONNECT
TO BLOCK IN RAFTER SPACE (32" o.c.
MAX.)
(E) MANSARD ROOF
FRAMING
(E) ROOF DECK
4x BLOCKING w/ SIMPSON
HU HANGERS, TYP.
SIMPSON CMSTC16 COIL
STRAP
SIMPSON HDU4 @ EA. DIAGONAL
BRACE (32" o.c. MAX.) w/ 4x
BLOCKING
(E) MANSARD ROOF FRAMING
AUDITORIUM WALL BRACING1/2"=1'-0"4
EXISTING ROOF TRUSS
(2) L5x5x3/8 x REQ'D LENGTH A36
KICKERS, (1) AT EA. SIDE OF
COLUMN, WITH (3) 3/4"Ø A307 THRU-
BOLTS AT WOOD BEAM, CENTER
MIDDLE BOLT ON BEAM DEPTH, TYP.
(E) ROOF RAFTER
(E) ROOF DECK
HSS 10x10x3/8 COLUMN, MIN. OF (4) ALONG NORTHERN
WALL, ATTACHED TO URM WALL w/ L6x4x3/8 x 0'-4" A36
ANGLES @ 24" o.c. STAGGERED w/ 3/4"Ø ANCHOR, TYP.
HSS 6x6x3/8 HORIZ. STRONGBACK @ 9'-10" o.c. MAX
w/ L4x4x3/8 x 0'-4" A36 @ 24" o.c. MAX w/ 3/4"Ø
ANCHOR, TYP.
EXISTING CEILING FRAMING AND FINISH
EXISTING WOOD FLOORING ON
2x SLEEPERS OVER 4" CONC.
FLOOR
(E) URM WALL
(E) EXTERIOR URM
WALL AT THE WESTERN
ENTRANCE
3
(6) #14x3-1/2" WOOD
SCREWS
(E) EXTERIOR URM
WALL AT MAIN
ENTRANCE
(E) ROOF JOIST(E) PARAPET EXTENDS
ABOVE ROOF LINE
(E) WATER- PROOFING
(E) CONC.
LINTEL AT
OPENING
HSS4x4x3/8 COLUMN
@ 4'-0" o.c. ATTACHED
TO URM WALL w/
L6x4x3/8 x 0'-4" ANGLES
@ 24" o.c. MAX. w/ 3/4"Ø
ANCHOR, TYP.
L4x4x1/4 x REQ'D LENGTH COMPRESSION
STRUT WITH (1) 3/4"Ø A307 THRU-BOLT, TYP.
(E) ROOF RAFTER
(E) ROOF DECK
(3) #14x3" WOOD SCREWS
CENTERED ON (E) CEILING JOIST
(5) SIMPSON SDS25112
HSS4x4x3/8 STRONGBACK
@ 4'-0" o.c.
(1) 3/4"Ø A307 THRU-BOLT
12x10 DF No. 1 - MATCH (E)
BEAM DEPTH & RIP TO 10"
WIDTH. ALIGN w/ COLUMN.
USE (4) SIMPSON HGA 10's, (2)
@ EA. END, TO ATTACH TO (E)
FRAMING, TYP.
16"
MIN
.
HSS 6x6x3/8 HORIZ. STRONGBACK
@ 10'-0" MAX o.c. w/ L4x4x3/8 x 0'-4"
A36 ANGLES @ 24" o.c. MAX w/
3/4"Ø ANCHOR, TYP.
PL3/8x6 x 2'-11" A36
BACK PLATE
(E) URM WALL
(E) URM WALL
(3) 3/4"Ø ANCHORS PER BACK PLATE.
INSTALL ANCHORS & BACK PLATE
BEFORE STRONGBACK. MAY NOTCH
BACK OF STRONGBACK TO FIT OVER
MIDDLE ANCHOR HEAD, IF REQ'D
L3x3x1/4 x 0'-6" A36 ANGLES
WELDED TO BACK PLATE
SUPPORTING HSS HORIZ.
STRONGBACK
L4x4x1/4 x 0'-6" A36
ANGLES WELDED TO HSS
COLUMN SUPPORTING HORIZ.
STRONGBACK
L4x4x1/4x 0'-4" A36 ANGLES
WELDED TO HSS 4x4x3/8 COLUMN
SUPPORTING HORIZ.
STRONGBACK
L4x4x1/4 x 0'-5 1/2" A36 ANGLES WELDED
TO HSS 4x4x3/8 COLUMN SUPPORTING
HORIZ. STRONGBACK
AUDITORIUM STRONGBACK WALL COONECTION1/2"=1'-0"5
1/4" CAP PL
w/ SEAL
WELD
1/4" CAP PL W/
SEAL WELD
5/16TYP
FILL
GAP,
TYP.G
1/4TYP.
(1/4)
G
5/16TYP.
1/4TYP.
1/4TYP.
FILL GAP
TYP.
G
1/4TYP.
1/4TYP.
FILL GAP
TYP.
G5/16
TYP.
1/4(3)SIDES
TYP.
5/8"Ø ROD w/ HIT HY-200 w/ 7"
EMBEDMENT DEPTH, TYP.
DO NOT DAMAGE (E) REBAR
DURING DRILLING
1 1/2" MIN
EDGE DISTANCE,
TYP.
PL 1/4x4x 0'-4" SHEAR TAB,
CENTER ON COLUMN WIDTH
(E) LEDGER
2"
MIN
.
1/2"Ø HAS ROD DRILL & EPOXY w/
HILTI HIT-HY 200 w/ 2 3/4"
EMBEDMENT DEPTH
PL3/8x10 x 1'-6" A36
BASE PLATE G
(1/4)
1/4
HSS 4x4x3/8 HORIZ.
STRONGBACK @ 5'-0" o.c. MAX
w/ L6x4x3/8 x 0'-4" A36 @ 24" o.c.
MAX w/ 3/4"Ø ANCHOR, TYP.
PL3/8x4 1/2 x 0'-8 1/2"
A36 BASE PLATE
SISTER 2'-0" LONG 4x TO (E)
JOIST w/ (8) SIMPSON SDWS22500
FOR FULL COLUMN BEARING
SIMPSON A35 CLIPS @ 8" o.c.,
EA. SIDE, STAGGERED, w/
#6x1/2" SPAX SCREWS
ALONG LENGTH OF NEW
12x10 BEAM
L4x4x1/4 x 0'-5 1/2" A36 ANGLE WELDED
TO HSS 4x4x3/8 COLUMN SUPPORTING
HORIZ. STRONGBACK
1/4TYP.1/4
1/4(3) SIDES
TYP.
1/4(1/4)
G
2"Ø HOLE IN FRONT FACE
OF HSS TUBE (ANCHOR Ø +
1/16" IN BACK) FOR SOCKET
ACCESS
HSS 4x4x3/8 HORIZ.
STRONGBACK @ TOP w/
3/8"Ø ROD w/ HILTI HIT-HY
200 w/ 2 3/8 " EMBEDMENT
DEPTH, TYP.
SIMPSON HGA10 (1) ON EACH SIDE
OF SISTERED LVL
SIMPSON LTT20B w/
3/4"Ø ANCHOR AT EA.
COLUMN, TYP.
3"
3"
4" MIN.BEARING
1 1
/2"
TY
P.
ED
GE
DIS
TA
NC
E
(1/8)(1/8)
G
TYP.
1/4
G
1"MAX.
22 1
/2°
ALL URM ANCHORS: 3/4"Ø A307
THREADED ROD (BENT), DRILL
AND EPOXY w/ HILTI HIT-HY 70 w/
12" MIN. EMBEDMENT DEPTH TO
WITHIN 1" OF OPPOSITE WALL
SURFACE, TYP.
NOTE:
ALL URM ANCHORS: 3/4"Ø A307
THREADED ROD (BENT), DRILL
AND EPOXY w/ HILTI HIT-HY 70 w/
12" MIN. EMBEDMENT DEPTH TO
WITHIN 1" OF OPPOSITE WALL
SURFACE, TYP. REF. 5/S5.1 FOR
DIMS.
NOTE:
ALL URM ANCHORS: 3/4"Ø A307
THREADED ROD (BENT), DRILL
AND EPOXY w/ HILTI HIT-HY 70 w/
12" MIN. EMBEDMENT DEPTH TO
WITHIN 1" OF OPPOSITE WALL
SURFACE, TYP. REF. 5/S5.1 FOR
DIMS.
NOTE:
ALL URM ANCHORS: 3/4"Ø A307
THREADED ROD (BENT), DRILL
AND EPOXY w/ HILTI HIT-HY 70 w/
12" MIN. EMBEDMENT DEPTH TO
WITHIN 1" OF OPPOSITE WALL
SURFACE, TYP. REF. 5/S5.1 FOR
DIMS.
NOTE:
Po
rtla
nd
Pa
rks
an
d R
ecr
ea
tio
n
REVISIONSDATE BYDESCRIPTION
SE
CT
ION
:D
RA
WN
BY
:D
AT
E:
PR
OJE
CT
MA
NA
GE
R:
MA
RLO
ME
DE
LLIN
SC
ALE
:
$FI
LE$
$D
AT
E$
PLO
TT
ED
ON
:D
RA
WIN
G:
NOTE:SCALE INDICATED ON DRAWINGIS CORRECT IF DRAWINGBORDER IS 22" X 34".
PLO
TT
ED
BY
:$
US
ER
NA
ME
$P
LOT
TE
D F
RO
M:
$C
OM
PU
TE
RN
AM
E$
Am
an
da
F
ritz
,
C
om
mis
sio
ne
r
-
Mik
e A
bb
até
,
Dir
ect
or
Mu
ltn
om
ah
Art
s C
en
ter
Vo
lun
tary
Se
ism
ic U
pg
rad
e
B
ID S
ET
76
88
SW
Ca
pit
ol
Hig
hw
ay
P
ort
lan
d,
Ore
go
n
architecture, interiors & planning
419 SW 11th Ave Suite 200
Portland, Oregon 97205
Phone: 503/228-7571
Fax: 503/273-8891
Portland, Oregon 97209
1640 NW Johnson Street
Phone: 503 243 6682
JULY
20
18
SC
AS
NO
TE
D
S5.1
SECTIONS AND DETAILS
CORRIDOR WALL BRACING1/2"=1'-0"1
(E) WOOD CORRIDOR
WALL
A34 CLIP ON EA. SIDE AT
EA. BRACE LOCATION, TYP.
(E) CELING JOISTS
ADD 2x4 DF NO.2
BRACING @ 4'-0" o.c.
MAX. SPACING (E) WOOD CRIPPLE
WALL
(E) ROOF DECK
(E) ROOF
JOISTS
(6) # 14 x 3 1/2"
WOOD SCREWS
CONT. 2x6 DF NO.2 @
MID-LENGTH OF BRACES.
ATTACH TO EA. BRACE w/ (3)
10d NAILS, TYP.
11
Po
rtla
nd
Pa
rks
an
d R
ecr
ea
tio
n
REVISIONSDATE BYDESCRIPTION
SE
CT
ION
:D
RA
WN
BY
:D
AT
E:
PR
OJE
CT
MA
NA
GE
R:
MA
RLO
ME
DE
LLIN
SC
ALE
:
$FI
LE$
$D
AT
E$
PLO
TT
ED
ON
:D
RA
WIN
G:
NOTE:SCALE INDICATED ON DRAWINGIS CORRECT IF DRAWINGBORDER IS 22" X 34".
PLO
TT
ED
BY
:$
US
ER
NA
ME
$P
LOT
TE
D F
RO
M:
$C
OM
PU
TE
RN
AM
E$
Am
an
da
F
ritz
,
C
om
mis
sio
ne
r
-
Mik
e A
bb
até
,
Dir
ect
or
Mu
ltn
om
ah
Art
s C
en
ter
Vo
lun
tary
Se
ism
ic U
pg
rad
e
B
ID S
ET
76
88
SW
Ca
pit
ol
Hig
hw
ay
P
ort
lan
d,
Ore
go
n
architecture, interiors & planning
419 SW 11th Ave Suite 200
Portland, Oregon 97205
Phone: 503/228-7571
Fax: 503/273-8891
Portland, Oregon 97209
1640 NW Johnson Street
Phone: 503 243 6682
JULY
20
18
SC
AS
NO
TE
D
S5.2
SECTIONS AND DETAILS