baby scar gamma radiography - ndt · pdf filewho we are conventional and advanced ndt and...

18
DACON INSPECTION SERVICES SCAR RADIOGRAPHY SCAR and ‘Baby’ SCAR GAMMA RADIOGRAPHY

Upload: vanphuc

Post on 18-Feb-2018

240 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES

SCAR RADIOGRAPHY

SCAR and ‘Baby’ SCAR

GAMMA RADIOGRAPHY

Page 2: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

Who we are

Conventional and

Advanced NDT and

Inspection Services

Oil and Gas, Refinery,

Petrochemical, Heavy

Industry, Mining

Over 400 personnel

including more than

300 inspectors

Thailand headquarters

with International

expertise since 1979

Page 3: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Operational Excellence - Our Customers

Page 4: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

SCAR

Small Controlled Area Radiography Two different SCAR systems

1. ‘Baby’ SCAR 989 Se 75, (Max 20 Curie) 2. SCAR 959M. 80 Ci of Se 75 or 15 Ci of Ir 192

Page 5: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

• Se-75 working range of 5-30mm steel thickness

• Ir 192 working range of 10-50mm steel thickness

• Se-75 has a softer gamma ray spectrum (66-401 keV)

than Iridium-192 (295-612 keV)

• Se 75 = Half Life of 119.8 days, (120 days)

• Ir 192 = Half Life of 73.83 days. (74 days)

Approx 46 days difference

SCAR

Page 6: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Baby SCAR Projector

Page 7: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

SCAR Radiography

• Se75 is mid-thickness gamma radiography

• ‘Baby’ SCAR has a tungsten shield

• Weighs 7.5 kg

• ‘Encapsulated source’ NEVER leaves container

Page 8: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Baby SCAR Projector

Baby SCAR container showing lock device and beam port.

Page 9: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Octagonal Cross Section

Pellet shape improves Geometric Unsharpness

therefore better quality radiograph

Page 10: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Octagonal Cross Section

Diagonal of the octagonal

pellet is 1.145 times pellet

diameter. Diagonal of cylinder

of the same diameter,

is 1.414 times its diameter.

The pellet geometry allows

source to be up to 23.5%

closer. This increases exposure

rate per Curie at the object.

Page 11: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Projector Placement

Page 12: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Shielding Projector

Page 13: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Survey Safe Distance

Page 14: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Record Measurement of Safe Zone

Page 15: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Reduced Area of Safe Zone From Football Pitch Size to Centre Circle Or Less

Page 16: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

Baby SCAR Radiography

Advantages of SCAR System

Safety Improvements - daylight working

No Downtime

Allows Continuous Construction Work

Schedules Maintained or Improved

On-line Radiography - Allows Instant Welder Performance Monitoring

‘Nucleonics’ Type instruments Not Affected

Page 17: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

SCAR Summary

• SCAR + Baby SCAR is safe to use 24 hours a day - no need for specific

radiography windows.

• Cost efficient.

• The barriered area is always very small, plus collimation less than 10 m

diameter (SCAR).

• Safe area is easier to see & control.

• SCAR will rarely affect other work.

• Equipment fits most pipe geometries.

• SCAR can replace most conventional radiography when planned in

advance.

Page 18: Baby SCAR GAMMA RADIOGRAPHY - NDT · PDF fileWho we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400

DACON INSPECTION SERVICES P E R F O R M A N C E Y O U C A N T R U S T

How Can We Help?

Contact

Tim Shaw

Chief Marketing Officer

Email : [email protected]

Mobile Phone : +66 (0) 89 245 9966

www.dacon-inspection.com