2
Why use baffled flasks? Due to limited oxygen transfer, cell growth is restricted in standard Erlenmeyer flasks Larger surface of the content results in a higher possible oxygen intake due to increased gas exchange area Baffled flasks – interrupt the laminar flow to create a turbulent flow – increase the surface of the liquid and the gas exchange surface – produce a higher oxygen transfer compared to standard Erlenmeyer flasks Benefits of DURAN ® baffled flasks completely automated machine manufacturing = reproducible geometry = comparable results complete with membrane screw cap (reproducible gas exchange) with retrace code (batch certificate via Internet) Comparison of the produced microbial mass (experiment with E.coli bacteria): DURAN ® BAFFLED FLASKS DURAN ® Erlenmeyer flask DURAN ® baffled flask 0 0.5 1 1.5 2 2.5 3 3.5 Microbial Mass (g/L) DURAN Group GmbH • Hattenbergstrasse 10 • D-55122 Mainz • info.duran@duran-group.com • www.duran-group.com

Upload: boom-bv

Post on 26-Mar-2016

213 views

Category:

Documents


1 download

DESCRIPTION

Chicanekolven van Duran, natuurlijk verkrijgbaar bij Boom B.V., wilt u weten waarom en wanneer u juist chicanekolven moet gebruiken? lees dan deze brochure, vragen? neem contact op met een van onze collega's

TRANSCRIPT

Why use baffled flasks?

● Due to limited oxygen transfer, cell growth is restricted in standard Erlenmeyer flasks

● Larger surface of the content results in a higher possible oxygen intake due to increased gas exchange area

● Baffled flasks

– interrupt the laminar flow to create a turbulent flow

– increase the surface of the liquid and the gas exchange surface

– produce a higher oxygen transfer compared to standard Erlenmeyer flasks

Benefits of DURAN® baffled flasks

● completely automated machine manufacturing

= reproducible geometry

= comparable results

● complete with membrane screw cap (reproducible gas exchange)

● with retrace code (batch certificate via Internet)

Comparison of the produced microbial mass (experiment with E.coli bacteria):

DURAN® BAFFLED FLASKS

DURAN® Erlenmeyer flask

DURAN® baffled flask

0

0.5

1

1.5

2

2.5

3

3.5

Mic

robi

al M

ass

(g/L

)

DURAN Group GmbH • Hattenbergstrasse 10 • D-55122 Mainz • [email protected] • www.duran-group.com

AP

PR

OX

.V

OL

.

200

300

400

500

Made in Germany

500 ml

Retrace Code00000000

NARUD

OHCS

200

300

400

500

Made in Germany

500 ml

Retrace Code00000000

NARUD

OHCS±5%

Movement of fluid on an orbital shaker:

Cat. No. Description Pack/Quantity

21 283 36 5 DURAN® baffled flask, GL 45, with 4 bottom baffles, complete with membrane screw cap and pouring ring, PP, 250 ml

4

21 283 44 5 DURAN® baffled flask, GL 45, with 4 bottom baffles, complete with membrane screw cap and pouring ring, PP, 500 ml

4

Order information:

When cultivating microorganisms in Erlenmeyer flasks on an orbital shaker, the oxygen intake is frequently the limiting factor for cell growth. The DURAN® Erlenmeyer flask with four baffles on the bottom interrupts the laminar flow to create a turbulent flow. The surface of the liquid and the gas exchange surface is increased, so that the oxygen intake can be increased.

DURAN® Erlenmeyer flask DURAN® baffled flask

DURAN Group GmbH • Hattenbergstrasse 10 • D-55122 Mainz • [email protected] • www.duran-group.com