balokoniniai armavimo elemetai halfen hit

41
HALFEN HIT HALFEN HIT INSULATED CONNECTION INSULATED CONNECTION 1 BALKONINIAI ARMAVIMO ELEMENTAI

Upload: stanislavas-puodziunas

Post on 12-Apr-2017

1.307 views

Category:

Engineering


5 download

TRANSCRIPT

Page 1: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

1

BALKONINIAI ARMAVIMO ELEMENTAI

Page 2: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

2

OverviewOverview

1. Introduction2. Applications3. Product overview4. Structural calculations5. Competition & market6. Advantages7. Distribution8. Technical literature & contacts9. Summary

Page 3: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

3

1. Introduction

1.1 Application, effect, function Application: Connecting balcony slabs, beams, projecting parapets, other projecting

construction elements as well as full storey-high projecting walls

Effect: Thermal separation avoids condensation and the formation of moulds; it

also reduces heat losses and its associated CO2 emissions

Function: Thermally separated reinforcement system for connecting detached

reinforced concrete components to the building

Page 4: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

4

1. Introduction

1.2 State of technology According to recent technical standards, the junctions between balconies

and buildings have to be thermally separated. The intention is to interrupt the flow of heat from the inside to the outside. This is achieved by inserting insulation between the two components.

“…thermally separated construction should be used…”DIN 4108 Supplement 2:2006-01

Page 5: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

5

1. Introduction

1.2 State of technologyOur solutionHalfen – Insulated – ElemenT → HIT

“A reinforcement element for providing a thermally insulated connection between reinforced concrete elements and concrete.”

Page 6: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

6

OverviewOverview

1. Introduction2. Applications3. Product overview4. Structural calculations5. Competition & market6. Advantages7. Distribution8. Technical literature & contacts9. Summary

Page 7: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

7

2. Applications

2.1 Application examplesExamples:

cantilevered balcony

outside corner balcony

HIT-HP MV HIT-HP MV

HIT-HP MV HIT-HP MV

Page 8: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

8

2. Applications

2.1 Application examplesExamples:

HIT-BD HIT-BDHIT-BD

HIT-BQ

Supported balcony

Loggia

Loggia

HIT-BD

HIT-BQ

HIT-BQ

Page 9: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

9

Overview Overview

1. Introduction2. Applications3. Product overview4. Structural calculations5. Competition & market6. Advantages7. Distribution8. Technical literature & contacts9. Summary

Page 10: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

10

Naming Concept

HALFEN HIT HPHALFEN HIT SP Insulation thickness : 120 mm

Insulation thickness : 80 mm

Superior Performance

Compression Shear Bearing

High Performance

3. Product overview

3.1 The HIT of the 2nd Generation

10

Page 11: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

11

HIT-HP MV-1008-20-100-35

Prod

uct d

escr

iptio

n

M =

Mom

ent

V =

Shea

r for

ce

No.

of t

ensi

on b

ars

Num

ber o

f CSB

Hei

ght [

cm]

Wid

th [c

m]

Con

cret

e co

ver [

mm

]

HP:

80

mm

In

sula

tion

3. Product overview

3.1 The HIT of the 2nd GenerationNaming concept

11

Page 12: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

12

Stainless steel compression bearings and shear

bars Unequal thermal insulation regarding fire

protection requirements

Balcony Ceiling

HIT (1. Generation)

Compression shear bearings (CSB) made of ultra-high strength fibre-reinforced mortar Equal thermal insulation due to rock wool

HIT-HP/SP (2. Generation)

12

Balcony Ceiling

3. Product overview

3.1 The HIT of the 2nd Generation

Support Support

Page 13: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

13

Flash-butt-welded tension

Compression shear bearing (CSB) made of ultra-high strength fibre-reinforced mortar

Casing for TB made of plastic

material

Mineral wool as insulation against fire and

low temperature

Assembly

13

Concrete steelStainless blank steel with fixing ringEnd Cap

Eligible for 80 mm and 120 mm

3. Product overview

3.1 The HIT of the 2nd Generation

Page 14: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

1414

Bild einführen

3. Product overview

3.1 The HIT of the 2nd Generation

HIT-HP MV, B=100cm, B=50cm, B=25cm

For cantilevering balcony slabs Transfers bending moments and shear forces Most frequent application case

Page 15: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

15

3. Product overview

3.1 Products

HIT-BX±Q, HIT-BF±QThe new HIT-HP-MD / HIT-SP-MD

For cantilevering balcony slabs Transfer of shear forces in positive

and negative direction Suitable for precast concrete works (two-part

element with upper and lower part HIT-BF±Q) Can also be supplied in a smaller version known

as “HIT module” (HIT-BX±Q-MOD)

Page 16: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

16

3. Product overview

3.1 Products

HIT-HP/-SP MV-OD

For cantilevering balcony slabs with stepped level Balcony slab is lower than the floor slab Transfer of bending moments and shear forces Suitable for element slabs (ES-Version)

Page 17: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

17

3. Product overview

3.1 Products

HIT-HP/-SP MV-OU

For cantilevering balcony slabs with stepped level Balcony slab is higher than the floor slab Transfer of bending moments and shear forces Suitable for element slabs (ES-Version)

Page 18: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

18

3. Product overview

3.1 Products

HIT-HP/-SP MV-OU

For cantilevering balcony slabs supported by a wallwith a upward connection

Transfer of bending moments and shear forces Suitable for element slabs (ES-Version)

Page 19: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

19

3. Product overview

3.1 Products

HIT-HP/-SP MV-OD

For cantilevering balcony slabs supported by a wall with an downward connection

Transfer of bending moments and shear forces Suitable for element slabs (ES-Version)

Page 20: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

20

3. Product overview

3.1 Products

HIT-HP/-SP MV

For cantilevering balconies at external corners Use of standard elements, no special element required Transfer of bending moments and shear forces via external corner

Indirect support

Direct support

Page 21: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

21

3. Product overview

3.1 Products

HIT-BQThe new HIT-HP-ZV / HIT-SP-ZV• For balcony slabs with non-restrained bearing

on uprights• Transfer of shear forces• Available in 1 m length and shorter (30/40/50 cm)• 12 load groups

Page 22: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

22

3. Product overview

3.1 Products

HIT-BDThe new HIT-HP-DD / HIT-SP-DD• For balcony slabs projecting from floor slab fields (continuous slabs)• Transfer of positive and negative moments

and shear forces• 3 load groups

Page 23: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

23

3. Product overview

3.1 Products

HIT-FT(The new planned) Insulation between front-mounted parapet and

floor/ceiling slab Short pieces (30 cm) for point application 1 load group

Page 24: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

24

3. Product overview

3.1 Products

HIT-OT(The new planned) Insulation between console and ceiling slab Short pieces (30 cm) for point application 1 load group

Page 25: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

25

3. Product overview

3.1 Products

HIT-AT(The new planned) Insulation between parapet and ceiling slab Short pieces (30 cm) for point application 1 load group

Page 26: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

26

3. Product overview

3.1 Products

HIT-ST

Insulation between consoles/cantilever beam and wall Point transfer of high bending moments and

shear forces Variations require many non-standard designs 4 load groups

Page 27: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

27

3. Product overview

3.1 Products

HIT-WT

Insulation of projecting walls with full storey-height

Point transfer of bending moments and shear forces, mainly in vertical direction Variations require many non-standard designs 4 load groups

Page 28: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

28

Overview Overview

1. Introduction2. Applications3. Product overview4. Structural calculations5. Competition & market6. Advantages7. Distribution8. Technical literature & contacts9. Summary

Page 29: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

29

1. StepFinding the necessary shearforce

4. Structural calculations4.1 Structural safety

Procedure for component configuration

29

Requirements for above shown example:

h = 180 mmcv = 35 mmconcrete C25/30

MEd = 35 kNm/mVEd = 60 kN/m

Component 1 m

Page 30: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

30

2. Step:Search for the concrete cover!

3. Step:Search for the slab thickness!

4. Step:Search for the necessary moment!

5. StepIdentify the necessary element!

4. Structural calculations4.1 Structural safetyProcedure for component configuration

Page 31: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

3131

The HIT of the 2nd Generation

The abbreviation REI has the following meaning :

R The structural safety of the connection is ensured for the specified duration

E The room-separating effect of the connection is ensured for the specified duration

I The thermal insulating ability of the connection is ensured for the specified duration

120 The functions above mentioned are ensured for 120 minutes of fire exposure in compliance with the standard

time/temperature curve

4. Structural calculations

4.2 Fire protection

Page 32: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

3232

The temperature field in the cross-section (shown as isotherms) illustrates the advantages of the HALFEN HIT Insulated connection for the required minimum thermal insulation

4. Structural calculations

4.3 Thermal protection

Page 33: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

3333

For normal load ranges of the slab connections the thermal transmission coefficient and the temperature factor are listed in tables.

4. Structural calculations

4.3 Thermal protection

Page 34: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

34

4. Structural calculations

4.4 Sound insulationWith balconies and access balconies, vibration is transferred into the main structure of the building and distributed into adjacent rooms as airborne sound.

DIN 4109 specifies the maximum level of airborne sound pressure level, which penetrates to the adjacent units of the building and which is measured with a standardized tapping machine.

erf. L´n,W = 53 dB

The standard versions of HALFEN HIT insulated connections can fulfill the sound insulation requirements for balconies.

Page 35: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

35

4. Structural calculations

4.4 Sound insulation

Basis: laboratory testsFrom laboratory measurements, the difference

in the impact sound pressure level ΔL was examined on a balcony slab made with units in

comparison to a continuous floor slab.

Page 36: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

36

4. Structural calculations

4.6 Software

current version: HIT 7.20 used intuitively 12 languages 11 calculation codes manual customisation facility for optimisation

Page 37: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

37

Overview Overview

1. Introduction2. Applications3. Product overview4. Structural calculations5. Competition & market6. Advantages7. Distribution8. Technical literature & contacts9. Summary

Page 38: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

38

5. Competition & market

5.2 Competition

Schöck Isokorb H-Bau Isopro Plakabeton IsotecEGCO Egcobox

www.schoeck.com www.h-bau.de www.egco.info www.plakabeton.com

AVI Thermokorb SFS Isolan Aschwanden ArboBasys Basycon

HALFEN HIT

www.avi.at www.sfslocher.biz www.basys.ch www.aschwanden.ch

Page 39: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

39

Overview Overview

1. Introduction2. Applications3. Product overview4. Structural calculations5. Competition & market6. Advantages7. Distribution8. Technical literature & contacts9. Summary

Page 40: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

40

8. Technical literature & contacts

8.2 Installation instructions

Multilingual assembly instruction

Page 41: Balokoniniai armavimo elemetai HALFEN HIT

HALFEN HITHALFEN HIT INSULATED CONNECTION INSULATED CONNECTION

41

Kontaktai

Stanislavas Puodžiūnase: [email protected]: +370 655 78565w: www.denia.lt