basic ueh exception

32
Title Doc. Nr. Revision Date 4/8/2010 Abstract Revision History PA1 ETCHLUO Open Issues References Ref[1] UEH Exception for NTC Purpose_PA3 Ref[2] UEH_EXCEPTION Introduction A UEH Exception Decriptions for Troubleshoot PA1 This workbook contains the description of UEH_E live network. It opens a way to investigate the root 2

Upload: zehara

Post on 08-Apr-2016

505 views

Category:

Documents


16 download

TRANSCRIPT

Page 1: Basic UEH Exception

Title

Doc. Nr.

Revision

Date 4/8/2010

Abstract

Revision History

PA1 ETCHLUO

Open Issues

References Ref[1] UEH Exception for NTC Purpose_PA3

Ref[2] UEH_EXCEPTION Introduction

A UEH Exception Decriptions for Troubleshooting in Live Network

PA1

This workbook contains the description of UEH_EXCEPTION Codes for troubleshooting purpose in the

live network. It opens a way to investigate the root cause of the problem in depth step by step.

C:\elxmm\2009Feb21\ueh_

Page 2: Basic UEH Exception

First draft

A UEH Exception Decriptions for Troubleshooting in Live Network

PA1

This workbook contains the description of UEH_EXCEPTION Codes for troubleshooting purpose in the

live network. It opens a way to investigate the root cause of the problem in depth step by step.

C:\elxmm\2009Feb21\ueh_

C:\elxmm\2009Feb21\ueh_

Page 3: Basic UEH Exception

Codes rbId

171 -

529 -

223 -

521 -

54 2

222 -

Page 4: Basic UEH Exception

141 -

552 -

220 -

221 -

12 -

200 -

500 -

533 -

142 -

327 -

318 -

54 -

276 -

Page 5: Basic UEH Exception

545 -

409 -

201 -

351 -

311 -

Page 6: Basic UEH Exception

523 -

407 -

54 3

225 -

800 -

563 -

80 -

54 16

350 -

331 -

283 -

940 -

607 -

509 -

Page 7: Basic UEH Exception

6 -

310 -

110 -

400 -

554 -

501 -

557 -

352 -

921 -

757 -

120 -

140 -

504 -

850 -

711 -

359 -

Page 8: Basic UEH Exception

210 -

54 4

512 -

365 -

10 -

122 -

Page 9: Basic UEH Exception

601 3

660 -

312 -

281 -

404 -

650 -

405 -

11 -

57 -

451 -

180/181/182/183/184 -

310/311/312/327 -

54 -

521/523/552 -

58 -

800 -

54 -

181 -

350/351 -

220/221/222 -

171 -

529 -

Page 10: Basic UEH Exception

EC_String

Received signal admissionRej on rnhIfCellControlP

TIMER inactivityDchTimerId has expired

Received signal decreaseResourceReq on RnhIfCellEventP

TIMER rrcSetuptimerId has expired

Received signal spProcessingFailure on DcsIfEventP

Received signal cellLockedInd on RnhIfCellEventP

Page 11: Basic UEH Exception

Received signal ranapDisconnectInd on UehRanapProcP

TIMER T_CH_SWITCH_1 has expired (DCH<->FACH)

Received signal eulLockedInd on RnhIfCellEventP

Received signal hsDschLockedInd on RnhIfCellEventP

Received signal faultyTrBrInd on DrhIfTrBrP

Received signal cellParamsRC2CharRej on RnhIfCellInfoP

TIMER T_RABEST_1 has expired waiting for RRC Radio Bearer Setup Response

TIMER rcsHsRlLostTimerId has expired

Received signal ranapInitialUeRej on UehRanapProcP

Received signal NBAP RADIO LINK FAILURE INDICATION

Received signal NBAP COMMON MEASUREMENT INITIATION FAILURE

Received signal spProcessingFailure on DcsIfEventP

Security Check failed for Cell or Ura update message

Page 12: Basic UEH Exception

TIMER esvRrcTimerId has expired

Received signal RRC Physical Channel Reconfiguration Failure

Received signal cellParamsRej on RnhIfCellInfoP

Received signal RNSAP RADIO LINK ADDITION FAILURE

Received signal NBAP RADIO LINK ADDITION FAILURE

Page 13: Basic UEH Exception

TIMER timer_RRC_ASU has expired

Received signal RRC CellUpdate with Failure Cause

Received signal spProcessingFailure on DcsIfEventP

Received signal capabilityChangeInd on RnhIfCellEventP

LOGICAL ERROR IN RANAP RAB ASSIGNMENT REQUEST

TIMER rcsAllRlLostTimerId has expired

Received signal rrcConnRejectInd on RnhIfRrcP

Received signal spProcessingFailure on DcsIfEventP

Received signal RNSAP RADIO LINK SETUP FAILURE

Received an NBAP Message Reject

Failed to build Ranap Relocation Required

INTERNAL STATE INCOMPATIBLE WITH REQUESTED OPERATION

Internal Subsystem Communication barred (Uu)

TIMER tcpmPcr has expired

Page 14: Basic UEH Exception

Received signal connNotOk on DrhIfDcRhDcP

Received signal NBAP RADIO LINK SETUP FAILURE

Received signal messageReject on UehNbapDedicatedP

Received signal RRC Radio Bearer Setup Failure

TIMER T_CH_SWITCH_3 has expired (DCH->DCH)

TIMER T_RABEST_1 has expired waiting for RRC Radio Bearer Reconfiguration Complete

TIMER UehRrcCellChangeHsTimer

Received signal RNSAP RADIO LINK RECONFIGURATION FAILURE

UNEXPECTED UL RRC DCCH MESSAGE TYPE

LOGICAL ERROR IN RRC RADIO BEARER RECONF COMPLETE

Received signal messageReject on UehRnsapDedicatedSrncP

Received signal messageReject on UehRanapProcP

TIMER T_RABREL_1 has expired waiting for RRC Radio Bearer Release Response

LOGICAL ERROR FAILED TO DECODE RRC MESSAGE

LOGICAL ERROR IN RNSAP RADIO LINK READY IND

Received signal RNSAP RADIO LINK FAILURE INDICATION

Page 15: Basic UEH Exception

Received signal asynch_forcedReleaseInd on UehUeCtxtAsynchIndicP

Received signal spProcessingFailure on DcsIfEventP

TIMER cellChangeTimerId has expired

Received a RNSAP Message Reject

Received signal setupLocalIpUdpTrBrRej on DrhIfTrBrP

Received signal sccpConnectionDisconnectionInd on UehRnsapDedicatedSrncP

Page 16: Basic UEH Exception

Internal Subsystem Communication barred (UEH)

LOGICAL ERROR IN NBAP RL FAILURE IND

Received signal NBAP RADIO LINK RECONFIGURATION FAILURE

Unhandled GPEH Service Class in call to incrementGpehCounter

Received signal RRC Measurement Control Failure

LOGICAL ERROR IN NBAP RADIO LINK SETUP RESPONSE

Received signal RRC Radio Bearer Reconfiguration Failure

Received signal setupTrBrRej on DrhIfTrBrP

Received signal interRATHandoverExInd on DcsIfEventP with invalid targetId

Received signal RANAP Relocation Preparation Failure

Page 17: Basic UEH Exception

Causes Impact

Admisson rejected due to following limitation: 1

Congestion

2 AseUl - Admission limit for UL ASE exceeded

3 AseDl - Admission limit for DL ASE exceeded

4 DlPwr

5 DlCode

6 SF8

7 SF16

8 SF32

9 CompModeLimit

10 CellDeactivated

11 RoutingFailure

12 LoadSharing

13 UniSaalCongestion

14 RbsUlHwResources

15 RbsDlHwResources

16 PhysHsChanLimit

17 SF4UL

18 SF8UL

19 SF16UL

20 SF8gUL

21 SF16g

22 EdchLimitServingCell

23 EdchLimitNonServingCell,

24 SctpCongestion

Performance degrade

The inactivityDchTimer defines the maximum time of inactivity on the

DCH allowed after the establishment of a RRC connection in

CELL_DCH. It is restarted at the reception of the following messages:

Downlink Direct Transfer

Uplink Direct Transfer

Initial Direct Transfer After timeout, releasing the

signaling connection is a normal behaviour for an UE in state

CELL_DCH with Stand-alone SRB only to save system resources.

No impact

Congestion Control in RNC requested to decrease the resources usage

on the existing connections of cell in congestion to admit a new

connection or service with higher QoS priority by pre-emption or

channel switching, system resources released.

Call drop

Timeout waiting neither RRC Connection Setup Complete or NBAP

Radio Link Restore Indication, caused by coverage or RF

environmental related issues, like power, interference, shadowing,

and so on...

Performance degrade

RLC data transport failure on SRB2, caused by coverage or RF

environmental related issues, like power, interference, shadowing,

and so on...

Call drop

Locking cell caused many affected UeContexts release. Call drop

Page 18: Basic UEH Exception

The SRNC might receive an unexpected SCCP release indication for an

established Iu connection. This could be initiated by either of the

following:

a) A SCCP RLSD message sent from the CN is received by the SRNC.

b) A local detection in SRNC on that the SCCP connection is lost. After

reception of the SCCP release indication for one CN if the UE had

signalling connections towards two CNs, all resources associated

with the CN for which the SCCP release indication comes is released.

The signalling connection towards the other CN remains.

Call drop

Timeout waiting RRC Radio Bear Reconfiguration Complete for

ChannelSwitching in between Cell_DCH and Cell_FACH, caused by

coverage or RF environmental related issues, like power, interference,

shadowing, and so on...

Call drop

Locking Eul channel caused many affected UeContexts release.Call drop

Locking hsDsch channel caused many affected UeContexts release.Call drop

Call drop

Resource calculation(Mapping parameters) for Radio Connection was

not passed for a new RRC connection establishment or radio link

setup, caused by capability limitation of the cell in current snapshot.Performance degrade

Call drop

For a connection that includes HSDPA, the PS part of the connection is

considered lost by the RCS when the RLS that contains the Serving HS-

DSCH cell, has been out-of-sync for a time given by the parameter

hsDschRcLostT. This means that when the hsDschRcLostT timer

expires, an Iu Release will be requested to the PS CN and when the

dchRcLostT timer expires, an Iu Release will be requested to all

involved CNs. It caused by coverage or RF environmental related

issues, like power, interference, shadowing, and so on...

Call drop

Case 1: Establishing a signaling connection to CN but the Ue reference

has already have an iuSigConnId, the ranapInitialUeMessage was

rejected, but sent over RANAP Direct Transfer to CN instead.

Case 2: In other case could be RANAP failure causing the

commuication to CN lost completely.

Depends

See NBAP REJECT CAUSE Depends

See NBAP REJECT CAUSE Performance degrade

RLC data transport failure on RB, caused by coverage or RF

environmental related issues, like power, interference, shadowing,

and so on...

Call drop

Security algorithm syncing failure in state CellUpdate or UraUpdate,

see details on following ErrorCode 545Call drop

Page 19: Basic UEH Exception

Timeout waiting for RRC Security Mode Complete, caused by

RLC_RESET PDU received at pending RX activation of Ciphering

configuration in SecurityControl, UL message(SecurityMode Command

Complete) in SRB was discared. It's often a clash between different

RNC and/or CN procedures.

Call drop

1 Configuration Unsupported

2 Physical Channel Failure

3 Incompatible Simultaneous Reconfiguration

4 Compressed mode runtime error

5 Protocol Error

6 Cell Update Occurred

7 Invalid Configuration

8 Configuration Incomplete

9 Unsupported Measurement

10 MBMS Session Already Received Correctly

11 Lower Priority MBMS Service

12 Spare5

13 Spare4

14 Spare3

15 Spare2

16 Spare1

In the case of ChannelSwitching from Cell_FACH to Cell_DCH, it often

the UE failed to establish the physical channel(s) indicated in the

received CELL UPDATE CONFIRM message. When a physical dedicated

channel establishment is initiated by the UE, the UE shall start a timer

T312 and wait for layer 1 to indicate N312 "in sync" indications. On

receiving N312 "in sync" indications, the physical channel is

considered established and the timer T312 is stopped and reset. If the

timer T312 expires before the physical channel is established, the UE

shall consider this as a "physical channel failure". In such a situation,

coverage or RF environmental issues are always the contributor.

Performance degrade

Cell specific info is fetched from TopCell (doff, measurementId,

nodePhasediff, nodePhaseDiffAcc, primaryCPICHPower,

ulInterference, lac, rac, sac, individualoffset).Call drop, or Performance

degrade, depends

IUB FrameSynch DL: TimingAdj CtrlFrame received with ToA > ToAE,

i.e. "crazy off"Performance degrade

Processing hardware unavailable in RBS was received. Performance degrade

Page 20: Basic UEH Exception

Timeout waiting for RRC Active Set Update Complete, caused by

coverage or RF environmental related issues, like power, interference,

shadowing, and so on...

Call drop

1 Configuration Unsupported

2 Physical Channel Failure

3 Incompatible Simultaneous Reconfiguration

4 Compressed mode runtime error

5 Protocol Error

6 Cell Update Occurred

7 Invalid Configuration

8 Configuration Incomplete

9 Unsupported Measurement

10 MBMS Session Already Received Correctly

11 Lower Priority MBMS Service

12 Spare5

13 Spare4

14 Spare3

15 Spare2

16 Spare1

Call drop

RLC data transport failure on SRB3,caused by coverage related issues

like out of coverage, poor coverage, or environmental related issues

like interference, shadowing

Call drop

IE in RANAP RAB ASSIGNMENT REQUEST was not supportedPerformance degrade

Radio Connection Supervision function was timeout, all Radio links

lost, caused by coverage related issues like out of coverage, poor

coverage, or environmental related issues like interference,

shadowing

Call drop

RLC data transport failure for RB16(PS Interactive),caused by coverage

or RF environmental related issues, like power, interference,

shadowing, and so on...

Call drop

See NBAP REJECT CAUSE Performance degrade

1 Encode failed

2 Timeout

3 Transaction removed

Call drop

Performance degrade

CN Hard Handover for PS rab + CS signalling connection was not

supported

Connection to Ue lost, RRC communication failure Performance degrade

Call drop

Page 21: Basic UEH Exception

A Cell program restarted causing internal communication broken to

DcRh.Performance degrade

See NBAP REJECT CAUSE

1 Encode failed

2 Timeout

3 Transaction removed

Case 1: If the Ue roams to a different cell during the Radio Bearer

Setup Procedure the Radio Bearer Setup attempt will fail because the

UE will not be able to

switch to DCH in the original cell while handling a Cell Update to the

new cell. The Ue will send a Radio Bearer Failure in this situation on

the CCH in the

new cell. (The Radio Bearer Setup Failure transaction Id will be

different to the Radio Bearer Setup Transaction Id). The Failure can

thus be ignored and

the use case continues normally (The Cell Update (new cell) is handled

and the RAB Establishment continues from the propagation delay

request. In the case where it is a Cell Update Same Cell,).

Case 2: If the RADIO BEARER SETUP FAILURE is received on the CCH of

the same cell (The transaction Ids are the same), it indicates that the

RAB Establishment has failed in that cell. In this situation, the

resources (dedicated and common) seized for the connection are

released as described in the T_RABEST_1 timeout case.

Call drop

Call drop

Timeout waiting for RRC Radio Bearer Reconfiguration Complete,

caused by coverage or RF environmental related issues, like power,

interference, shadowing, and so on…

Timeout waiting for RRC Cell Change Complete, caused by coverage or

RF environmental related issues, like power, interference, shadowing,

and so on…

Call drop

The RRC message received was not the one expected, Ue was not in

sync with RNCPerformance degrade

Uplink Counter Synchronisation IE not present in RRC RADIO BEARER

RECONF COMPLETE messageCall drop

1 Encode failed

2 Timeout

3 Transaction removed

1 Encode failed

2 Timeout

3 Transaction removed

Timeout waiting RRC Radio Bearer Release Response, caused by

coverage or RF environmental related issues, like power, interference,

shadowing, and so on…

Call drop

InvalidConfiguration in RRC MESSAGE or error decoding UL DCCH

messagePerformance degrade

Call drop

See NBAP REJECT CAUSE Call drop

Page 22: Basic UEH Exception

The function is initiated by RANAP unavailable (a Core Networks is

down), a cell unavailable, cell program restart, PDR SP unavailable,

Cello unavailable,congestion, Pool congestion or RNSAP unavailable.

Call drop

RLC data transport failure on SRB4, caused by coverage or RF

environmental related issues, like power, interference, shadowing,

and so on…

Call drop

Timeout waiting for RRC Cell Change, caused by coverage or RF

environmental related issues, like power, interference, shadowing,

and so on…

1 Encode failed

2 Timeout

3 Transaction removed

Call drop

400 drhTrBr_failedUnspecified

401 drhTrBr_rncModuleDown

402 drhTrBr_trBrNotFound

403 "drhTrBr_failedToInsertTrBr"

404 drhTrBr_cppNciRestartOnMp

405 drhTrBr_cppNciNetConnRej

406 drhTrBr_cppNciNodeConnRej

407 drhTrBr_cppNciDiscInd

408 drhTrBr_cepNotFound

409 drhTrBr_failedToInsertCep

410 drhTrBr_eriServerNotReadyForCepComm

411 drhTrBr_cppEriCepReject

412 drhTrBr_cppEriRestartOnMp

413 drhTrBr_auditOngoing

414 drhTrBr_spRestart

415 drhTrBr_ipHostNotFound

416 drhTrBr_failedToInsertIpTp

417 drhTrBr_cppSciSessionSetupRej

418 drhTrBr_ipTpNotFound

419 drhTrBr_cppSciSessionModifyRej

420 drhTrBr_auditInconsistency

421 drhTrBr_cppSciTrafficIndSessionReleased

422 drhTrBr_ipSessionReleased

It's often caused by the underlying TNL resource unavailable

temporarily.

Call drop

The SRNC might receive an unexpected SCCP release indication for an

established Iu connection. This could be initiated by either of the

following:

a) A SCCP RLSD message sent from the CN is received by the SRNC.

b) A local detection in SRNC on that the SCCP connection is lost. After

reception of the SCCP release indication for one CN if the UE had

signalling connections towards two CNs, all resources associated

with the CN for which the SCCP release indication comes is released.

The signalling connection towards the other CN remains.

Depends

Page 23: Basic UEH Exception

The communication in between UEH and DCS was broken, caused by

the release of SRB due to spProcessing failure.Call drop

Logical error in IE RL_InformationResponseList_RL_SetupRspFDD_PDU

1 Configuration Unsupported

2 Physical Channel Failure

3 Incompatible Simultaneous Reconfiguration

4 Compressed mode runtime error

5 Protocol Error

6 Cell Update Occurred

7 Invalid Configuration

8 Configuration Incomplete

9 Unsupported Measurement

10 MBMS Session Already Received Correctly

11 Lower Priority MBMS Service

12 Spare5

13 Spare4

14 Spare3

15 Spare2

16 Spare1

Setting up AAL2 connection got remote reject due to resource

temporary failure.Call drop

GSM Cell target Id could not be mapped to a GSM cell reference in

UehUeCtxt data, wrong data in GSM relation.Performance degrade

CN or BSC failed to prepare the resources for IRATHO Performance degrade

See Ref[1]

See Ref[1]

See Ref[1] and Ref[2]

See Ref[1]

See Ref[1] and Ref[2]

See Ref[1] and Ref[2]

See Ref[1] and Ref[2]

See Ref[1]

See Ref[1]

See Ref[1] and Ref[2]

See Ref[2]

See Ref[2]

Page 24: Basic UEH Exception

Trace Object

uehUeCtxtC* 1,3,6,7,enter,return

uehUeCtxtC* 1,3,7,enter,return

Page 25: Basic UEH Exception

uehUeCtxtC* 6,7,enter,return RANAP_ASN

bus_send, bus_receive

uehUeCtxtC* 1,3,6,7,enter,return

UE_TRBR_HANDL 3

UE_GENERAL 3

RRC_ASN bus_send, bus_receive

RANAP_ASN bus_send, bus_receive

CON_HANDL 1,6,7

NBAP_ASN bus_send, bus_receive

DRIFT_DED 6,7

RRC_ASN bus_send, bus_receive

uehUeCtxtC* 1,3, enter, return

Page 26: Basic UEH Exception

CHAN_SWITCH 6,7

CELL_UPDATE 5,6,7

DRIFT_DED 6,7

IRAT_HANDOVER 6,7

RAB_EST 6,7

RAB_REL 3,5,6,7

CON_HANDL 6,7

NBAP_ASN bus_send, bus_receive

RNSAP_ASN bus_send, bus_receive

CON_HANDL 6,7

HANDOVER 1,3,6,7,state_change,enter,return

NBAP_ASN bus_send, bus_receive

RNSAP_ASN bus_send, bus_receive

CON_HANDL 6,7

HANDOVER 1,3,6,7,state_change,enter,return

Page 27: Basic UEH Exception

RRC_ASN bus_send, bus_receive

HANDOVER 6,7

RRC_ASN bus_send, bus_receive

CELL_UPDATE 6,7

GENRAB_EVAL 1,3

GRC_SERV 1,3

RANAP_ASN bus_send, bus_receive

CN_HARD_HANDOVER 6,7

IRAT_HANDOVER 1,6,7

RRC_ASN bus_send, bus_receive

COMPRESSED_MODE 2,6,7

HS_CELL_CHANGE 6,7

POWER_CTRL 6,7

IF_HANDOVER 2,3,6,7

HANDOVER 6,7

Page 28: Basic UEH Exception

RRC_ASN bus_send, bus_receive

IRAT_HANDOVER 2,6,7

RAB_EST 3,6,7

Page 29: Basic UEH Exception

UE_TRBR_HANDL 6,7

Page 30: Basic UEH Exception
Page 31: Basic UEH Exception

Radio Network Layer Cause

0 Unkown C-ID,

1 Cell not available,

2 Power level not supported,

3 DL radio resources not available,

4 UL radio resources not available,

5 RL Already Activated/allocated,

6 Node B Resources Unavailable,

7 Measurement not supported for the object,

8 Combining Resources not available,

9 Requested configuration not supported,

10 Synchronization failure,

11 Priority transport channel established,

12 SIB Origination in Node B not Supported,

13 Requested Tx Diversity Mode not supported,

14 Unspecified,

15 BCCH scheduling error,

16 Measurement Temporarily not Available,

17 Invalid CM Setting,

18 Reconfiguration CFN not elapsed,

19 Number of DL codes not supported,

20 S-CPICH not supported,

21 Combining not supported,

22 UL SF not supported,

23 DL SF not supported,

24 Common Transport Channel Type not supported,

25 Dedicated Transport Channel Type not supported,

26 Downlink Shared Channel Type not supported,

27 Uplink Shared Channel Type not supported,

28 CM not supported,

29 Tx diversity no longer supported,

30 Unknown Local Cell ID,

31 Number of UL codes not supported,

32 Information temporarily not available,

33 Information Provision not supported for the object,

34 Cell Synchronisation not supported,

35 Cell Synchronisation Adjustment not supported,

36 DPC Mode Change not Supported,

37 IPDL already activated,

38 IPDL not supported,

39 IPDL parameters not available,

40 Frequency Acquisition not supported,

41 Power Balancing status not compatible,

42 Requested type of Bearer Rearrangement not supported,

43 Signalling Bearer Rearrangement not supported,

44 Bearer Re-arrangement needed,

45 Delayed Activation not Supported,

Page 32: Basic UEH Exception

46 RL Timing Adjustment not supported,

47 MICH not supported,

48 F-DPCH Not Supported

Transport Layer Cause

Transport resource unavailable,

Unspecified,

Protocol Cause

Transfer syntax error,

Abstract syntax error (reject),

Abstract syntax error (ignore and notify),

Message not compatible with receiver state,

Semantic error,

Unspecified,

Abstract syntax error (falsely constructed message),

Miscellaneous Cause

Control processing overload

Hardware failure,

O&M intervention,

Not enough user plane processing resources,

Unspecified,