baying systems ts 8 - steven engineering

20
Baying systems TS 8 Height: 1200, depth: 500/height: 1400, depth: 500 138 Rittal Catalogue 32/Industrial Enclosures B 1.3 Baying systems TS 8 T F1 G1 H B B T F1 H G1 Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12. Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate. Approvals, see page 30. Detailed drawing/nominal dimensions, see page 1184 – 1185. Width (B) mm Packs of 600 800 1200 600 800 1200 Page Height (H) mm 1200 1200 1200 1400 1400 1400 Depth (T) mm 500 500 500 500 500 500 Mounting plate width (F1) mm 499 699 1099 499 699 1099 Mounting plate height (G1) mm 1096 1096 1096 1296 1296 1296 Model No. TS 1 8615.500 8815.500 8215.500 8645.500 8845.500 8245.500 Door(s) 1 1 2 1 1 2 Weight (kg) 74.5 92.1 140.0 86.0 107.5 163.5 Walls Side panels 2 8115.235 8115.235 8115.235 8145.235 8145.235 8145.235 917 Divider panel 1 8609.450 8609.450 8609.450 921 Base/plinth Components front and rear Height 100 mm 1 set 8601.600 8601.800 8601.200 8601.600 8601.800 8601.200 893 Height 200 mm 1 set 8602.600 8602.800 8602.200 8602.600 8602.800 8602.200 893 Trim panels (sides) Height 100 mm 1 set 8601.050 8601.050 8601.050 8601.050 8601.050 8601.050 893 Height 200 mm 1 set 8602.050 8602.050 8602.050 8602.050 8602.050 8602.050 893 Accessories Cable clamp rails for cable clamps 2 4191.000 4192.000 4196.000 4191.000 4192.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4947.000 4944.000 4945.000 4947.000 999 Support strips for door 20 4596.000 4598.000 4596.000 4596.000 4598.000 4596.000 964 Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 4116.000 4118.000 4116.000 967 Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Signal pillar LED compact, Model No. see page 1125. Baying cover, top, Model No. see page 932. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Upload: others

Post on 16-Oct-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Baying systems TS 8 - Steven Engineering

Baying systems TS 8Height: 1200, depth: 500/height: 1400, depth: 500

138 Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

T

F1

G1

H

BB

TF1

H

G1

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated

Protection category:IP 55 to EN 60 529/09.2000, complies with NEMA 12.

Supply includes:Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate.

Approvals, see page 30.

Detailed drawing/nominal dimensions, see page 1184 – 1185.

Width (B) mm Packs of 600 800 1200 600 800 1200 Page

Height (H) mm 1200 1200 1200 1400 1400 1400

Depth (T) mm 500 500 500 500 500 500

Mounting plate width (F1) mm 499 699 1099 499 699 1099

Mounting plate height (G1) mm 1096 1096 1096 1296 1296 1296

Model No. TS 1 8615.500 8815.500 8215.500 8645.500 8845.500 8245.500Door(s) 1 1 2 1 1 2

Weight (kg) 74.5 92.1 140.0 86.0 107.5 163.5

WallsSide panels 2 8115.235 8115.235 8115.235 8145.235 8145.235 8145.235 917

Divider panel 1 – – – 8609.450 8609.450 8609.450 921

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.600 8601.800 8601.200 8601.600 8601.800 8601.200 893

Height 200 mm 1 set 8602.600 8602.800 8602.200 8602.600 8602.800 8602.200 893

Trim panels (sides)Height 100 mm 1 set 8601.050 8601.050 8601.050 8601.050 8601.050 8601.050 893

Height 200 mm 1 set 8602.050 8602.050 8602.050 8602.050 8602.050 8602.050 893

AccessoriesCable clamp rails for cable clamps 2 4191.000 4192.000 4196.000 4191.000 4192.000 4196.000 1061

Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4947.000 4944.000 4945.000 4947.000 999

Support strips for door 20 4596.000 4598.000 4596.000 4596.000 4598.000 4596.000 964

Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 4116.000 4118.000 4116.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request.

Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329

Signal pillar LED compact, Model No. see page 1125.

Baying cover, top, Model No. see page 932.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 2: Baying systems TS 8 - Steven Engineering

Height: 1600, depth: 500

Baying systems TS 8

139Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329

T

F1

G1

H

BB

TF1

H

G1

Width (B) mm Packs of 600 800 1200 Page

Height (H) mm 1600 1600 1600

Depth (T) mm 500 500 500

Mounting plate width (F1) mm 499 699 1099

Mounting plate height (G1) mm 1496 1496 1496

Model No. TS 1 8665.500 8865.500 8265.500Door(s) 1 1 2

Weight (kg) 100.0 103.0 159.3

WallsSide panels 2 8165.235 8165.235 8165.235 917

Divider panel 1 8609.650 8609.650 8609.650 921

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.600 8601.800 8601.200 893

Height 200 mm 1 set 8602.600 8602.800 8602.200 893

Trim panels (sides)Height 100 mm 1 set 8601.050 8601.050 8601.050 893

Height 200 mm 1 set 8602.050 8602.050 8602.050 893

AccessoriesCable clamp rails for cable clamps 2 4191.000 4192.000 4196.000 1061

Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4947.000 999

Support strips for door 20 4596.000 4598.000 4596.000 964

Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request.

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated

Protection category:IP 55 to EN 60 529/09.2000, complies with NEMA 12.

Supply includes:Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate.

Approvals, see page 30.

Detailed drawing/nominal dimensions, see page 1184 – 1185.

Connector gland for connecting a keyboard, mouse or scanner, Model No. see page 1057.

Hinge attachment for partial mounting plates, Model No. see page 985.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 3: Baying systems TS 8 - Steven Engineering

Baying systems TS 8Height: 1800, depth: 400

140 Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

Width (B) mm Packs of 600 800 1000 1000 1200 Page

Height (H) mm 1800 1800 1800 1800 1800

Depth (T) mm 400 400 400 400 400

Mounting plate width (F1) mm 499 699 899 899 1099

Mounting plate height (G1) mm 1696 1696 1696 1696 1696

Model No. TS 1 8684.500 8884.500 8084.500 8080.500 8284.500Door(s) 1 1 1 2 2

Weight (kg) 91.3 113.5 136.4 140.0 170.6

WallsSide panels 2 8184.235 8184.235 8184.235 8184.235 8184.235 917

Divider panel 1 8609.840 8609.840 8609.840 8609.840 8609.840 921

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.600 8601.800 8601.000 8601.000 8601.200 893

Height 200 mm 1 set 8602.600 8602.800 8602.000 8602.000 8602.200 893

Trim panels (sides)Height 100 mm 1 set 8601.040 8601.040 8601.040 8601.040 8601.040 893

Height 200 mm 1 set 8602.040 8602.040 8602.040 8602.040 8602.040 893

AccessoriesCable clamp rails for cable clamps 2 4191.000 4192.000 4336.000 4336.000 4196.000 1061

Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4946.000 4946.000 4947.000 999

Support strips for door 20 4596.000 4598.000 4599.000 4309.000 4596.000 964

Wiring plan pocket, sheet steel 1 4116.000 4118.000 4124.000 4115.000 4116.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request.

Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Ppage 632

T

F1

G1

H

BB

TF1

H

G1

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated

Protection category:IP 55 to EN 60 529/09.2000, complies with NEMA 12.

Supply includes:Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate.

Accessories:Corner enclosures, see page 933.

Possible alternative:

Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634.

Approvals, see page 30.

Detailed drawing/nominal dimensions, see page 1184 – 1185.

Snap-on nut for screw-fastening to the vertical section, Model No. see page 1005.

System window to protect against unauthorised access and preserve the protec-tion category, Model No. see page 943.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 4: Baying systems TS 8 - Steven Engineering

Height: 1800, depth: 500

Baying systems TS 8

141Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

T

F1

G1

H

BB

TF1

H

G1

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated

Protection category:IP 55 to EN 60 529/09.2000, complies with NEMA 12 (except TS 8485.510).

Supply includes:Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate.

Accessories:Corner enclosures, see page 933.

Possible alternative:

Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634.

Approvals, see page 30.

Detailed drawing/nominal dimensions, see page 1184 – 1185.

Width (B) mm Packs of 400 600 800 800 1200 Page

Height (H) mm 1800 1800 1800 1800 1800

Depth (T) mm 500 500 500 500 500

Mounting plate width (F1) mm – 499 699 699 1099

Mounting plate height (G1) mm – 1696 1696 1696 1696

Model No. TS 1 8485.5101) 8685.500 8885.500 8880.500 8285.500Door(s) 1 1 1 2 2

Weight (kg) 49.2 93.8 115.8 122.5 173.3

WallsSide panels 2 8185.235 8185.235 8185.235 8185.235 8185.235 917

Divider panel 1 8609.850 8609.850 8609.850 8609.850 8609.850 921

Divider panel for module plates 1 8609.100 8609.100 8609.100 8609.100 8609.100 922

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.400 8601.600 8601.800 8601.800 8601.200 893

Height 200 mm 1 set 8602.400 8602.600 8602.800 8602.800 8602.200 893

Trim panels (sides)Height 100 mm 1 set 8601.050 8601.050 8601.050 8601.050 8601.050 893

Height 200 mm 1 set 8602.050 8602.050 8602.050 8602.050 8602.050 893

AccessoriesCable clamp rails for cable clamps 2 4193.000 4191.000 4192.000 4192.000 4196.000 1061

Cable clamp rails (C section) for cable clamps 6 – 4944.000 4945.000 4945.000 4947.000 999

Support strips for door 20 – 4596.000 4598.000 4594.000 4596.000 964

Wiring plan pocket, sheet steel 1 – 4116.000 4118.000 4114.000 4116.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

1) Without tubular door frame, mounting plate and gland plates. Available to order as accessories: Mounting plate, see page 987, gland plates, see from page 911. To order enclosures in textured RAL 7032 please add extension .600 or .610 to the Model No., and for primed enclosures use extension .800 or .810.Delivery times available on request.

Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632

Interface flap for safe, modular accommoda-tion of sockets and interfaces, Model No. see page 1151.

Compact light for space-saving installation on a vertical or horizontal section, Model No. see page 1027.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 5: Baying systems TS 8 - Steven Engineering

Baying systems TS 8Height: 1800, depth: 600

142 Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside

Mounting plates and gland plates: Zinc-plated

Supply includes:Enclosure frame with doors, mounting plate, gland plates, rear panel, roof plate and 2 support strips(TS 4696.000, see page 997), fitted in the enclosure depth.

Protection category:IP 55 to EN 60 529/09.2000, complies with NEMA 12 (except TS 8486.510).

Accessories:Corner enclosures, see page 933.

Possible alternative:

Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634.

Approvals, see page 30.

Detailed drawing/nominal dimensions, see page 1184 – 1185.

Width (B) mm Packs of 400 600 800 800 1200 Page

Height (H) mm 1800 1800 1800 1800 1800

Depth (T) mm 600 600 600 600 600

Mounting plate width (F1) mm – 499 699 699 1099

Mounting plate height (G1) mm – 1696 1696 1696 1696

Model No. TS 1 8486.5101) 8686.500 8886.500 8881.500 8286.500Door(s) 1 1 1 2 2

Weight (kg) 51.7 96.8 120.3 125.8 179.9

WallsSide panels 2 8186.235 8186.235 8186.235 8186.235 8186.235 917

Divider panel 1 8609.860 8609.860 8609.860 8609.860 8609.860 921

Divider panel for module plates 1 8609.110 8609.110 8609.110 8609.110 8609.110 922

Climate control side panel 1 3331.XXX 3331.XXX 3331.XXX 3331.XXX 3331.XXX 635

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.400 8601.600 8601.800 8601.800 8601.200 893

Height 200 mm 1 set 8602.400 8602.600 8602.800 8602.800 8602.200 893

Trim panels (sides)Height 100 mm 1 set 8601.060 8601.060 8601.060 8601.060 8601.060 893

Height 200 mm 1 set 8602.060 8602.060 8602.060 8602.060 8602.060 893

AccessoriesCable clamp rails for cable clamps 2 4193.000 4191.000 4192.000 4192.000 4196.000 1061

Cable clamp rails (C section) for cable clamps 6 – 4944.000 4945.000 4945.000 4947.000 999

Support strips for door 20 – 4596.000 4598.000 4594.000 4596.000 964

Wiring plan pocket, sheet steel 1 – 4116.000 4118.000 4114.000 4116.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

1) Without tubular door frame, mounting plate and gland plates. Available to order as accessories: Mounting plate, see page 987, gland plates, see from page 913. To order enclosures in textured RAL 7032 please add extension .600 or .610 to the Model No., and for primed enclosures use extension .800 or .810.Delivery times available on request.

T

F1

G1

H

BB

TF1

H

G1

TFT monitor for installation in doors and side panels, Model No. see page 1133.

Gland plates, Model No. see from page 911.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 6: Baying systems TS 8 - Steven Engineering

Height: 2000, depth: 400

Baying systems TS 8

143Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated

Protection category:IP 55 to EN 60 529/09.2000, complies with NEMA 12.

Supply includes:Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate.

Accessories:Corner enclosures, see page 933.

Possible alternative:

Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634.

Approvals, see page 30.

Detailed drawing/nominal dimensions, see page 1184 – 1185.

Width (B) mm Packs of 600 800 1000 1200 Page

Height (H) mm 2000 2000 2000 2000

Depth (T) mm 400 400 400 400

Mounting plate width (F1) mm 499 699 899 1099

Mounting plate height (G1) mm 1896 1896 1896 1896

Model No. TS 1 8604.500 8804.500 8004.500 8204.500Door(s) 1 1 2 2

Weight (kg) 99.0 124.0 152.8 184.5

WallsSide panels 2 8104.235 8104.235 8104.235 8104.235 917

Divider panel 1 8609.040 8609.040 8609.040 8609.040 921

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.600 8601.800 8601.000 8601.200 893

Height 200 mm 1 set 8602.600 8602.800 8602.000 8602.200 893

Trim panels (sides)Height 100 mm 1 set 8601.040 8601.040 8601.040 8601.040 893

Height 200 mm 1 set 8602.040 8602.040 8602.040 8602.040 893

AccessoriesCable clamp rails for cable clamps 2 4191.000 4192.000 4336.000 4196.000 1061

Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4946.000 4947.000 999

Support strips for door 20 4596.000 4598.000 4309.000 4596.000 964

Wiring plan pocket, sheet steel 1 4116.000 4118.000 4115.000 4116.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request.

Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632

T

F1

G1

H

BB

TF1

H

G1

Cable trunking, vertical, to match the section and horizon-tally to match the mounting plate, Model No. see page 1059 – 1060.

Rail for EMC shielding brackets and cable clamps, Model No. see page 1031.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 7: Baying systems TS 8 - Steven Engineering

Baying systems TS 8Height: 2000, depth: 500

144 Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

T

F1

G1

H

BB

TF1

H

G1

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plate and gland plates: Zinc-plated

Protection category:IP 55 to EN 60 529/09.2000, complies with NEMA 12 (except TS 8405.510).

Supply includes:Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate.

Accessories:Corner enclosures, see page 933.

Possible alternative:

Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634.

Approvals, see page 30.

Detailed drawing/nominal dimensions, see page 1184 – 1185.

Width (B) mm Packs of 400 600 800 1000 1200 Page

Height (H) mm 2000 2000 2000 2000 2000

Depth (T) mm 500 500 500 500 500

Mounting plate width (F1) mm – 499 699 899 1099

Mounting plate height (G1) mm – 1896 1896 1896 1896

Model No. TS 1 8405.5101) 8605.500 8805.500 8005.500 8205.500Door(s) 1 1 1 2 2

Weight (kg) 60.7 101.3 126.3 157.1 190.6

WallsSide panels 2 8105.235 8105.235 8105.235 8105.235 8105.235 917

Divider panel 1 8609.050 8609.050 8609.050 8609.050 8609.050 921

Divider panel for module plates 1 8609.120 8609.120 8609.120 8609.120 8609.120 922

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.400 8601.600 8601.800 8601.000 8601.200 893

Height 200 mm 1 set 8602.400 8602.600 8602.800 8602.000 8602.200 893

Trim panels (sides)Height 100 mm 1 set 8601.050 8601.050 8601.050 8601.050 8601.050 893

Height 200 mm 1 set 8602.050 8602.050 8602.050 8602.050 8602.050 893

AccessoriesCable clamp rails for cable clamps 2 4193.000 4191.000 4192.000 4336.000 4196.000 1061

Cable clamp rails (C section) for cable clamps 6 – 4944.000 4945.000 4946.000 4947.000 999

Support strips for door 20 – 4596.000 4598.000 4309.000 4596.000 964

Wiring plan pocket, sheet steel 1 – 4116.000 4118.000 4115.000 4116.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956 and comfort handle, see page 947 – 948.

1) Without tubular door frame, mounting plate and gland plates. Available to order as accessories: Mounting plate, see page 987, gland plates, see from page 911. To order enclosures in textured RAL 7032 please add extension .600 or .610 to the Model No., and for primed enclosures use extension .800 or .810.Delivery times available on request.

Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632

Cable glands of polyamide or brass, Model No. see page 1054.

Keyboard, pull-out with integral trackball, Model No. see page 1137.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 8: Baying systems TS 8 - Steven Engineering

Height: 2000, depth: 600

Baying systems TS 8

145Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

T

F1

G1

H

BB

TF1

H

G1

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside

Mounting plates and gland plates: Zinc-plated

Supply includes:Enclosure frame with doors, mounting plate, gland plates, rear panel, roof plate and 2 support strips (TS 4696.000, see page 997), fitted in the enclosure depth.

Protection category:IP 55 to EN 60 529/09.2000, complies with NEMA 12 (except TS 8406.510).

Accessories:Corner enclosures, see page 933.

Possible alternative:

Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634.

Approvals, see page 30.

Detailed drawing/nominal dimensions, see page 1184 – 1185.

Width (B) mm Packs of 400 600 800 1000 1200 Page

Height (H) mm 2000 2000 2000 2000 2000

Depth (T) mm 600 600 600 600 600

Mounting plate width (F1) mm – 499 699 899 1099

Mounting plate height (G1) mm – 1896 1896 1896 1896

Model No. TS 1 8406.5101) 8606.500 8806.500 8006.500 8206.500Door(s) 1 1 1 2 2

Weight (kg) 55.7 104.0 130.5 161.2 194.6

WallsSide panels 2 8106.235 8106.235 8106.235 8106.235 8106.235 917

Divider panel 1 8609.060 8609.060 8609.060 8609.060 8609.060 921

Divider panel for module plates 1 8609.130 8609.130 8609.130 8609.130 8609.130 922

Climate control side panel 1 3331.XXX 3331.XXX 3331.XXX 3331.XXX 3331.XXX 635

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.400 8601.600 8601.800 8601.000 8601.200 893

Height 200 mm 1 set 8602.400 8602.600 8602.800 8602.000 8602.200 893

Trim panels (sides)Height 100 mm 1 set 8601.060 8601.060 8601.060 8601.060 8601.060 893

Height 200 mm 1 set 8602.060 8602.060 8602.060 8602.060 8602.060 893

AccessoriesCable clamp rails for cable clamps 2 4193.000 4191.000 4192.000 4336.000 4196.000 1061

Cable clamp rails (C section) for cable clamps 6 – 4944.000 4945.000 4946.000 4947.000 999

Support strips for door 20 – 4596.000 4598.000 4309.000 4596.000 964

Wiring plan pocket, sheet steel 1 – 4116.000 4118.000 4115.000 4116.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

1) Without tubular door frame, mounting plate and gland plates. Available to order as accessories: Mounting plate, see page 987, gland plates, see from page 911. To order enclosures in textured RAL 7032 please add extension .600 or .610 to the Model No., and for primed enclosures use extension .800 or .810.Delivery times available on request.

Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632

Section for cable entry for top mounting on gland plates with routing of the cable clamp strip, Model No. see page 1046.

Module plate for cable entry in the divider panel, Model No. see page 923 – 924.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 9: Baying systems TS 8 - Steven Engineering

Baying systems TS 8Height: 2000, depth: 800

146 Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

T

F1

G1

H

BB

TF1

H

G1

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated

Protection category:IP 55 to EN 60 529/09.2000, complies with NEMA 12.

Supply includes:Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate.

Accessories:Corner enclosures, see page 933.

Possible alternative:

Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634.

Approvals, see page 30.

Detailed drawing/nominal dimensions, see page 1184 – 1185.

Width (B) mm Packs of 600 800 1200 Page

Height (H) mm 2000 2000 2000

Depth (T) mm 800 800 800

Mounting plate width (F1) mm 499 699 1099

Mounting plate height (G1) mm 1896 1896 1896

Model No. TS 1 8608.500 8808.500 8208.500Door(s) 1 1 2

Weight (kg) 111.3 137.0 203.0

WallsSide panels 2 8108.235 8108.235 8108.235 917

Divider panel 1 8609.080 8609.080 8609.080 921

TS 8 internal fan mounting panel 1 3348.200 3348.200 3348.200 707

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.600 8601.800 8601.200 893

Height 200 mm 1 set 8602.600 8602.800 8602.200 893

Trim panels (sides)Height 100 mm 1 set 8601.080 8601.080 8601.080 893

Height 200 mm 1 set 8602.080 8602.080 8602.080 893

AccessoriesCable clamp rails for cable clamps 2 4191.000 4192.000 4196.000 1061

Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4947.000 999

Support strips for door 20 4596.000 4598.000 4596.000 964

Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request.

Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632

Punched section without mounting flange 45 x 88 mm The universal configuration solution with 11 rows of holes for heavy equipment and screw-fastening to the frame, Model No. see page 995.

Mounting plate attach-ment in conjunction with mounting plate infill, Model No. see page 979.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 10: Baying systems TS 8 - Steven Engineering

Height: 2200, depth: 600

Baying systems TS 8

147Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

T

F1

G1

H

BB

TF1

H

G1

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated

Protection category:IP 55 to EN 60 529/09.2000, complies with NEMA 12.

Supply includes:Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate.

Accessories:Corner enclosures, see page 933.

Approvals, see page 30.

Detailed drawing/nominal dimensions, see page 1184 – 1185.

Width (B) mm Packs of 600 800 1200 Page

Height (H) mm 2200 2200 2200

Depth (T) mm 600 600 600

Mounting plate width (F1) mm 499 699 1099

Mounting plate height (G1) mm 2096 2096 2096

Model No. TS 1 8626.500 8826.500 8226.500Door(s) 1 1 2

Weight (kg) 113.1 139.3 208.0

WallsSide panels 2 8126.235 8126.235 8126.235 917

Divider panel 1 8609.260 8609.260 8609.260 921

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.600 8601.800 8601.200 893

Height 200 mm 1 set 8602.600 8602.800 8602.200 893

Trim panels (sides)Height 100 mm 1 set 8601.060 8601.060 8601.060 893

Height 200 mm 1 set 8602.060 8602.060 8602.060 893

AccessoriesCable clamp rails for cable clamps 2 4191.000 4192.000 4196.000 1061

Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4947.000 999

Support strips for door 20 4596.000 4598.000 4596.000 964

Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request.

Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632

Gland plate with sealing bar for sub-dividing the base assembly for varying cable entry, Model No. see page 912.

Module plate with cable sleeves for cable diameters 10 – 65 mm, Model No. see page 924.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 11: Baying systems TS 8 - Steven Engineering

Baying systems TS 8Electronic enclosure

148 Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

T

H

B

465450

484

Z

Z

Material:Enclosure frame: Sheet steel, 1.5 mm Front frame: Extruded aluminium sections with die-cast corner pieces Rear door: 2 mm sheet steel Roof and gland plates: 1.5 mm sheet steelAdaptor sections: Aluminium

Surface finish:Enclosure frame: Dipcoat-primed Front frame, rear door and roof: Powder-coated in RAL 7035 Gland plates: Zinc-plated

Supply includes:Enclosure frame, front frame (r/h hinge, opening angle 130°, held via mechanical snap fas-teners on left), rear door (r/h hinge, may be swapped to opposite side), roof, adaptor sections and gland plates.

Approvals, see page 31.

Detailed drawing/nominal dimensions,see page 1186.

U Packs of 33 33 42 42 Page

Width (B) mm 600 600 600 600

Height (H) mm 1600 1600 2000 2000

Depth (T) mm 600 800 600 800

Model No. TS 1 8410.510 8418.510 8430.510 8438.510Door(s) 1 1 1 1

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.600 8601.600 8601.600 8601.600 893

Height 200 mm 1 set 8602.600 8602.600 8602.600 8602.600 893

Trim panels (sides)Height 100 mm 1 set 8601.060 8601.080 8601.060 8601.080 893

Height 200 mm 1 set 8602.060 8602.080 8602.060 8602.080 893

AccessoriesSide panels 2 8166.235 8168.235 8106.235 8108.235 917

Cable clamp rails for cable clamps 2 4191.000 4191.000 4191.000 4191.000 1061

Cable clamp rails (C section) for cable clamps 6 4944.000 4944.000 4944.000 4944.000 999

Adaptor sections for rear 2 8613.360 8613.360 8613.300 8613.300 1090

Lock systemsStandard double-bit lock insert (in rear door) may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

For primed enclosures, please add extension .810 to the Model No. Delivery times available on request.

Accessories Page 890 482.6 mm (19″) mounting accessories From page 1079 Subrack systems Page 548482.6 mm (19″) climate control Page 698 – 700

Slide rails, Model No. see page 1097.

Aluminium cross rail, for sub-division of the front, Model No. see page 1090.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 12: Baying systems TS 8 - Steven Engineering

For modular front design

Baying systems TS 8

149Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

T

H

B

The basic enclosures without ● Mounting plate

for universal interior installa-tion with − Partial mounting plates − Component shelves and

drawers − Punched sections and rails

● Doors Frame for the installation of − Partial doors with and

without viewing panels − Fully glazed doors − Drawers and desk sections − Profile blanking frame − Vertically divided doors − Trim panels hinged at the top

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm

Surface finish:Enclosure frame: Dipcoat-primed Door and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Gland plates: Zinc-plated

Supply includes:Enclosure frame, roof, rear panel, gland plates, three-piece.

Detailed drawing (TS basic enclosures without door), see page 1186.

Accessories Page 890 Partial doors Page 941 Partial mounting plates Page 984

Width (B) mm Packs of 600 800 Page

Height (H) mm 2000 2000

Depth (T) mm 600 600

Model No. TS 1 8606.512 8806.512Weight (kg) 52.5 63.0

WallsSide panels 2 8106.512 8106.512 942

Divider panel 1 8609.060 8609.060 921

Divider panel for module plates 1 8609.130 8609.130 922

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.600 8601.800 893

Height 200 mm 1 set 8602.600 8602.800 893

Trim panels (sides)Height 100 mm 1 set 8601.060 8601.060 893

Height 200 mm 1 set 8602.060 8602.060 893

To order enclosures in textured RAL 7032 please add extension .612 to the Model No., and for primed enclosures use extension .812. Delivery times available on request.

Trim panels TSFor height trim at the top and bottom, Model No. see page 941.

Protective bar and holder,Model No. see page 938.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 13: Baying systems TS 8 - Steven Engineering

Baying systems TS 8For isolator door locking

150 Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

TB

B2

H

F

G

Material:Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door and trim panel: 2.0 mm Mounting plate: 3.0 mm

Surface finish:Enclosure frame: Dipcoat-primedDoor, trim panel, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated

Protection category:IP 55 to EN 60 529/09.2000 Complies with NEMA 12 (with fitted/sealed isolator switch actuation)

Supply includes:Enclosure frame, door (l/h hinge), trim panel (r/h hinge, with a swing lever at the top and bottom, with cut-out for isolator switch actuation), roof, rear panel, mounting plate, three-piece gland plates.

Rittal service:Enclosures with 100 mm (instead of 200 mm) wide trim panel on request.

Approvals, see page 31.

Detailed drawing/nominal dimensions,see page 1187.

Width (B) mm Packs of 800 800 800 800 Page

Height (H) mm 1800 1800 2000 2000

Depth (T) mm 400 500 500 600

Mounting plate width (F) mm 699 699 699 699

Mounting plate height (G) mm 1696 1696 1896 1896

Model No. TS 1 8984.500 8985.500 8905.500 8906.500Door(s) 1 1 1 1

Weight (kg) 113.5 115.8 126.3 130.5

Base/plinth

Components front and rearHeight 100 mm 1 set 8601.800 8601.800 8601.800 8601.800 893

Height 200 mm 1 set 8602.800 8602.800 8602.800 8602.800 893

Trim panels (sides)Height 100 mm 1 set 8601.040 8601.050 8601.050 8601.060 893

Height 200 mm 1 set 8602.040 8602.050 8602.050 8602.060 893

Also requiredDoor latch for bayed suites 960

AccessoriesIsolator door locking (USA version) 1 8611.310 8611.310 8611.310 8611.310 960

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

To order enclosures in RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request.

Accessories Page 890 Adjacent door locking Page 951

Cable glandCable glands made from polyamide or brass, Model No. see page 1054.

Snap-on nutfor screw-fastening to the vertical section, Model No. see page 1005.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 14: Baying systems TS 8 - Steven Engineering

IP 66/NEMA 4x, NEMA 4

Baying systems TS 8

151Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

T

H

B

G

F

Material:NEMA 4x: Stainless steel 1.4301 (AISI 304)

NEMA 4: Sheet steel, spray-finished

Enclosure frame, roof, base/plinth, rear panel, side panels: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm (sheet steel)

Surface finish:NEMA 4x: Enclosure frame: Uncoated Door, roof, base, rear panel, side panels: Brushed on the outside, grain size 400 Mounting plate: Zinc-plated

NEMA 4: Enclosure frame, door, roof, base, rear panel, side panels: Dipcoat-primed and powder-coated in textured RAL 7035 on the outside Mounting plate: Zinc-plated

Protection category:IP 66 to EN 60 529/09.2000 (complies with NEMA 4x/ NEMA 4)

Supply includes:NEMA 4x/NEMA 4: Enclosure frame with door, roof/base plate, rear panel, side panels, mounting plate.

Rittal service:Enclosures with depth 800 mm on request.

Approvals, see page 31.

Packs of NEMA 4x, stainless steel NEMA 4, sheet steel Page

Width (B) mm 600 800 600 800 600 800 600 800

Height (H) mm 1800 1800 2000 2000 1800 1800 2000 2000

Depth (T) mm 600 600 600 600 600 600 600 600

Mounting plate width (F) mm 499 699 499 699 499 699 499 699

Mounting plate height (G) mm 1696 1696 1896 1896 1696 1696 1896 1896

Model No. TS 1 8458.640 8459.640 8452.640 8450.640 8686.540 8886.540 8606.540 8806.540Door(s) 1 1 1 1 1 1 1 1

Base/plinth

Components front and rearHeight 100 mm 1 set 8701.600 8701.800 8701.600 8701.800 8601.600 8601.800 8601.600 8601.800 893, 899

Height 200 mm 1 set 8702.600 8702.800 8702.600 8702.800 8602.600 8602.800 8602.600 8602.800 893, 899

Trim panels (sides)Height 100 mm 1 set 8701.060 8701.060 8701.060 8701.060 8601.060 8601.060 8601.060 8601.060 893, 899

Height 200 mm 1 set 8702.060 8702.060 8702.060 8702.060 8602.060 8602.060 8602.060 8602.060 893, 899

Base/plinth trim, modular SO 4 2913.000 2913.000 2913.000 2913.000 – – – – 899

AccessoriesCable clamp rails 2 4191.000 4192.000 4191.000 4192.000 4191.000 4192.000 4191.000 4192.000 1061

System support rails 2 4361.000 4362.000 4361.000 4362.000 4361.000 4362.000 4361.000 4362.000 1000

Support strips for door 20 4596.000 4598.000 4596.000 4598.000 4596.000 4598.000 4596.000 4598.000 964

Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 4118.000 4116.000 4118.000 4116.000 4118.000 967

Lock systemsStandard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948.

Delivery times available on request.

Accessories Page 890 Cable entry From page 1045

Cable glands IP 68Cable glands made from polyamide or brass, Model No. see page 1054.

Punched rail25 x 38 mm, Model No. see page 996.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 15: Baying systems TS 8 - Steven Engineering

Baying systems TS 8Prepared for EX pressurisation

152 Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

T

H

B

G

F

With this empty enclosure and an external overpressure con-troller such as those offered by STAHL, Bartec or Gönnheimer, conventional operating materi-als may be used in explosion hazard areas. To this end, a per-manent overpressure is applied to the enclosure which prevents the ingress of potentially explo-sive atmospheres. Empty enclosure, prepared for pressurisation, ensures efficient operation thanks to low leakage rates of approximately 20 l/min, at 2 mbar overpressure. Ex overpressure enclosures must be constructed and oper-ated in conformity with stand-ards DIN EN 60 079-0 and DIN EN 60 079-2.

For populated enclosures of pro-tection type “p”, in accordance with Directive 94/9 EC, type test-ing certification from a designat-ed office is required.

Design: ● Base as for roof ● Reinforced:

− Rear panel − Side panels − Door with additional cams

top and bottom, r/h hinge, l/h hinge on request

Surface finish:Sheet steel: Enclosure frame: Dipcoat-primed door, roof, base, side panels and rear panel: Dipcoat-primed, powder-coated in tex-tured RAL 7035 on the outside Mounting plate: Zinc-plated

Stainless steel: Enclosure frame: Uncoated Door, side panels, roof, base/plinth, and rear panel: Brushed, grain size 400 Mounting plate: Zinc-plated

Protection category:IP 55 to EN 60 529/09.2000 complies with NEMA 12

Supply includes:Enclosure frame with door (with additional cam top and bottom), roof/base plate, rear panel, side panels, mounting plate.

Rittal service:Enclosures for baying available on request.

Width (B) mm 600 800 600 800 600 800 1000 600 800 600 –

Height (H) mm 1400 1400 1600 1600 1800 1800 1800 1800 1800 1800 –

Depth (T) mm 500 500 500 500 400 400 400 500 500 600 –

Mounting plate width (F) mm 499 699 499 699 499 699 899 499 699 499 –

Mounting plate height (G) mm 1296 1296 1496 1496 1696 1696 1696 1696 1696 1696 –

Model No. TS sheet steel 8645.560 8845.560 8665.560 8865.560 8684.560 8884.560 8084.560 8685.560 8885.560 8686.560 –

Width (B) mm 800 600 800 600 800 600 800 600 800 600 800

Height (H) mm 1800 2000 2000 2000 2000 2000 2000 2000 2000 2200 2200

Depth (T) mm 600 400 400 500 500 600 600 800 800 600 600

Mounting plate width (F) mm 699 499 699 499 699 499 699 499 699 499 699

Mounting plate height (G) mm 1696 1896 1896 1896 1896 1896 1896 1896 1896 2096 2096

Model No. TS sheet steel 8886.560 8604.560 8804.560 8605.560 8805.560 8606.560 8806.560 8608.560 8808.560 8626.560 8826.560

Width (B) mm 800 1000 600 800 600 600 800 800 – – –

Height (H) mm 1800 1800 1800 1800 1800 2000 2000 2000 – – –

Depth (T) mm 400 400 500 500 600 600 600 800 – – –

Mounting plate width (F) mm 699 899 499 699 499 499 699 699 – – –

Mounting plate height (G) mm 1696 1696 1696 1696 1696 1896 1896 1896 – – –

Model No. TS stainless steel 8454.660 8461.660 8457.660 8455.660 8458.660 8452.660 8450.660 8460.660 – – –

Delivery times available on request.

Accessories Page 890 Cable entry From page 1045

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 16: Baying systems TS 8 - Steven Engineering

For areas at risk from earthquakes

Baying systems TS 8

153Rittal Catalogue 32/Industrial Enclosures

B

1.3

Bay

ing

syst

ems

TS 8

1

3

4

2

Accessories Page 890 Base/plinth Page 892

TS 8 for earthquake zone 1, 2 and 3 to Bellcore TS 8806.500: W x H x D 800 x 2000 x 600 mm

With base/plinth (base/plinth components front and rear and base/plinth trim, side, see page 893), 100 mm high with a weight load of 125 kg spread evenly over the mount-ing plate.

Note:These versions have been tested and meet the require-ments to Telcordia GR 63-CORE. They should be seen as a com-parative variable to the cus-tomer’s own plant, since the cer-tification of empty enclosures is not possible.

TS 8 for earthquake zone 4 to BellcoreTS 8806.500: W x H x D 800 x 2000 x 600 mm

Fitted with: ● Earthquake kit and ● Earthquake base/plinth,

see page 153,

with weight load of 450 kg distributed evenly over the mounting plate.

Rittal service:● Mounting on the enclosure on request.

Earthquake kit Material:Sheet steel

Surface finish:Zinc-plated, passivated

Supply includes: 2 side reinforcements, bottom

2 bracing struts each, sides

8 gusset plates

Mounting plate attachment and reinforcement including assembly parts

3

2

1

2

3

4

For enclosures W x H x D

mmPacks of Model No. TS

800 x 2000 x 600 1 8613.860600 x 2000 x 600 1 8613.6601) 600 x 2000 x 400 1 8613.6401)

1) Delivery times available on request.

4

Earthquake base/plinth Height 100 mmMaterial:Sheet steel Corner pieces: 5 mm Trim panels: 2 mm

Surface finish:Powder-coated in RAL 7022

Supply includes:1 set = ● 4 corner pieces ● 2 depth stays ● 1 trim panel each front and rear fully assembled.

For enclosures W x D mm

Packs of Model No. TS

800 x 600 1 8601.860600 x 600 1 8601.6601) 600 x 400 1 8601.6401)

1) Delivery times available on request.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 17: Baying systems TS 8 - Steven Engineering

Industrial EnclosuresLarge enclosures

1184 Rittal Catalogue 32/Industrial Enclosures

C

1.

Indu

stria

l Enc

losu

res

i.L. T3

35 35T7

i.L. H

3

H2

H1

463.5

444.5

64.5

30

H5

32.5

62.5i.L. T5

T4

G

5551

25

T6 2

17

T1

H9

H8

i.L. H

7

H6

96

71

i.L. B5

B6

71

22

H4

2.5

B7

B1

4 x

25 (

= 1

00)

Ø 4.6Ø 9

M6

60

H6

i.L. H

7

H8

H9

96

71

60

H4

222.

5

71

B6

i.L. B5

Ø 6

4 x

25 (

= 1

00)

Ø 9

M6

B6

i.L. B5

B1

B7

3030

T2

6565

T1

49 F 49

i.L. B8Ø 1678.5

78.5

30 30

B4

46.5

i.L. T

346

.5i.L. B3

B2

61 61

M12

1815

T1

T2

78.5

65

30

Ø 16

61

30

49

65

30

i.L. T

346

.5

78.5

M12

46.5

61

30

49

B4

F

i.L. B8

B2

i.L. B3

i.L. B8

1815

1

1.3 Baying system TS 8Spray-finished Page 138 – 147

Stainless steel Page 322

Note:With fitted side panels, the overall width (B1) is increased by 9 mm. Between bayed enclo-sures, allow 3 mm for the seal.

Does not apply to TS 8880.500/TS 8881.500

i.L. = Clearance width

1

Base/plinth mounting: B4 x T2 Base/plinth mounting: B4 x T2

Double-door

Model No. TS Width dimensions mm Height dimensions mm Depth dimensions mm Mounting plates mm

Spray-finished

Stainless steel B1 B2 B3 B4 B5 B6 B7 B8 H1 H2 H3 H4 H5 H6 H7 H8 H9 T1 T2 T3 T4 T5 T6 T7 F G

8215.500 – 1197 1192 1112 1075 455 475 1135 500 1205 1197 1112 1177.5 1075 1050 1030 1000 611 505 375 412 468 340 130 – 455 435 1099 1096

8245.500 – 1197 1192 1112 1075 455 475 1135 500 1405 1397 1312 1377.5 1275 1250 1230 1200 711 505 375 412 468 340 130 – 455 435 1099 1296

8080.500 – 997 992 912 875 355 375 935 400 1805 1797 1712 1777.5 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 899 1696

8284.500 8456.X00 1197 1192 1112 1075 455 475 1135 500 1805 1797 1712 1777.5 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 1099 1696

8880.500 – 797 792 712 675 255 275 735 640 1805 1797 1712 1777.5 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 699 1696

8285.500 8453.X00 1197 1192 1112 1075 455 475 1135 500 1805 1797 1712 1777.5 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 1099 1696

8881.500 – 797 792 712 675 255 275 735 640 1805 1797 1712 1777.5 1675 1650 1630 1600 911 605 475 512 568 440 130 – 555 535 699 1696

8286.500 – 1197 1192 1112 1075 455 475 1135 500 1805 1797 1712 1777.5 1675 1650 1630 1600 911 605 475 512 568 440 130 – 555 535 1099 1696

8004.500 – 997 992 912 875 355 375 935 400 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 405 275 312 368 240 130 – 355 335 899 1896

8204.500 – 1197 1192 1112 1075 455 475 1135 500 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 405 275 312 368 240 130 – 355 335 1099 1896

8005.500 – 997 992 912 875 355 375 935 400 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 899 1896

8205.500 – 1197 1192 1112 1075 455 475 1135 500 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 1099 1896

8006.500 – 997 992 912 875 355 375 935 400 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 899 1896

8206.500 8451.X00 1197 1192 1112 1075 455 475 1135 500 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 1099 1896

8208.500 – 1197 1192 1112 1075 455 475 1135 500 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 805 675 712 768 640 130 – 755 735 1099 1896

8226.500 – 1197 1192 1112 1075 455 475 1135 500 2205 2197 2112 2177.5 2075 2050 2030 2000 1111 605 475 512 568 440 130 – 555 535 1099 2096

8265.500 – 1197 1192 1112 1075 455 475 1135 500 1605 1597 1512 1577.5 1475 1450 1430 1400 811 505 375 412 468 340 130 – 455 435 1099 1496

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 18: Baying systems TS 8 - Steven Engineering

Large enclosures

Industrial Enclosures

1185Rittal Catalogue 32/Industrial Enclosures

C

1.

Indu

stria

l Enc

losu

res

73 48 24.5

23

17 23

F

42

24.5

G

236.5

25

12.5 4

25 12.5

4.5

i.L. (

T3)

i.L. (B3)

42.5

42.5

42.5

i.L. (

H3)

i.L. (B3/T3)

42.5 12

.5

11.5

4.5

12.5

12.5 4

10.525

20

Cross-sections vertical

Enclosure

Mounting plate

B1 =B2 =B3 =B4 =

B5 =B6 =

B7 =B8 =

H1 =H2 =H3 =H4 =H5 =H6 =

H7 =H8 =

H9 =

T1 =T2 =

T3 =T4 =T5 = T6 =

T7 =

Overall width Width of door Clearance between the enclosure frames Section length of system punchings/hole spacing base/plinth attachment Clearance between the tubular door frames Distance between axes of tubular door frame holes Distance between the lifting eyes Clearance in the base opening

Overall height Height of rear panel Clearance between the enclosure frame Height of door Section length of system punchings Distance between axes of tubular door frame holes Clearance between the tubular door frame Distance between the fastening bolts of the tubular door frame Distance from base to centre of lock

Overall depth Section length of system punchings/hole spacingClearance between the enclosure frames Depth of base frame Clearance of base opening Possible mounting depth (mounting plate assembly) depth-adjustable on a 25 mm pitch pattern Centre of lifting eye to centre of lifting eye

F = G =

Overall width Overall height

horizontal

Single-door

Model No. TS Width dimensions mm Height dimensions mm Depth dimensions mm Mounting plates mm

Spray-finished

Stainless steel B1 B2 B3 B4 B5 B6 B7 B8 H1 H2 H3 H4 H5 H6 H7 H8 H9 T1 T2 T3 T4 T5 T6 T7 F G

8615.500 – 597 592 512 475 455 475 535 440 1205 1197 1112 1177.5 1075 1050 1030 1000 611 505 375 412 468 340 130 – 455 435 499 1096

8815.500 – 797 792 712 675 655 675 735 640 1205 1197 1112 1177.5 1075 1050 1030 1000 611 505 375 412 468 340 130 – 455 435 699 1096

8645.500 – 597 592 512 475 455 475 535 440 1405 1397 1312 1377.5 1275 1250 1230 1200 711 505 375 412 468 340 130 – 455 435 499 1296

8845.500 – 797 792 712 675 655 675 735 640 1405 1397 1312 1377.5 1275 1250 1230 1200 711 505 375 412 468 340 130 – 455 435 499 1296

8684.500 – 597 592 512 475 455 475 535 440 1805 1797 1712 1777.5 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 499 1696

8884.500 8454.X00 797 792 712 675 655 675 735 640 1805 1797 1712 1777.5 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 699 1696

8084.500 – 997 992 912 875 855 875 935 840 1805 1797 1712 1777.5 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 899 1696

8485.510 – 397 392 312 275 255 275 335 240 1805 1797 1712 1777.5 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 – –

8685.500 8457.X00 597 592 512 475 455 475 535 440 1805 1797 1712 1777.5 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 499 1696

8885.500 8455.X00 797 792 712 675 655 675 735 640 1805 1797 1712 1777.5 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 699 1696

8486.510 – 397 392 312 275 255 275 335 240 1805 1797 1712 1777.5 1675 1650 1630 1600 911 605 475 512 568 440 130 – 555 535 – –

8686.500 – 597 592 512 475 455 475 535 440 1805 1797 1712 1777.5 1675 1650 1630 1600 911 605 475 512 568 440 130 – 555 535 499 1696

8886.500 – 797 792 712 675 655 675 735 640 1805 1797 1712 1777.5 1675 1650 1630 1600 911 605 475 512 568 440 130 – 555 535 699 1696

8604.500 – 597 592 512 475 455 475 535 440 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 405 275 312 368 240 130 – 355 335 499 1896

8804.500 – 797 792 712 675 655 675 735 640 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 405 275 312 368 240 130 – 355 335 699 1896

8405.510 – 397 392 312 275 255 275 335 240 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 – –

8605.500 – 597 592 512 475 455 475 535 440 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 499 1896

8805.500 – 797 792 712 675 655 675 735 640 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 699 1896

8406.510 – 397 392 312 275 255 275 335 240 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 – –

8606.500 8452.X00 597 592 512 475 455 475 535 440 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 499 1896

8806.500 8450.X00 797 792 712 675 655 675 735 640 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 699 1896

8608.500 – 597 592 512 475 455 475 535 440 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 805 675 712 768 640 130 – 755 735 499 1896

8808.500 – 797 792 712 675 655 675 735 640 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 805 675 712 768 640 130 – 755 735 699 1896

8626.500 – 597 592 512 475 455 475 535 440 2205 2197 2112 2177.5 2075 2050 2030 2000 1111 605 475 512 568 440 130 – 555 535 499 2096

8826.500 – 797 792 712 675 655 675 735 640 2205 2197 2112 2177.5 2075 2050 2030 2000 1111 605 475 512 568 440 130 – 555 535 699 2096

8665.500 – 597 592 512 475 455 475 535 440 1605 1597 1512 1577.5 1475 1450 1430 1400 811 505 375 412 468 340 130 – 455 435 499 1496

8865.500 – 797 792 712 675 655 675 735 640 1605 1597 1512 1577.5 1475 1450 1430 1400 811 505 375 412 468 340 130 – 455 435 699 1496

Mounting plate

i.L. = Clearance width

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 19: Baying systems TS 8 - Steven Engineering

Industrial EnclosuresLarge enclosures

1186 Rittal Catalogue 32/Industrial Enclosures

C

1.

Indu

stria

l Enc

losu

res

1605

/200

5

535/735

1512

/191

2

1466

.6 (

33 H

E)/

1866

.9 (

42 H

E)

465

� 9

.5

44.4

5 31.7

5

7.6

452

452

63

43 48653

592

592

512/

712

512

622/

822

1.3 Baying system TS 8 Electronic enclosures Page 148

HE = U

601.5

12.5

25

568

i.L. 440

77

42.5

4.5 44

3.5

46

2005

1997

i.L. 1

912

535 3135

i.L. 512

7718

50

597/797

18

M12

6161

512/712

42.5

i.L. 5

1246

.5

475/675

3030

Ø 16

601.

565

6547

5

3030

25 12.5

6.5

25

4.5

12.5 4

42.5

42.5

i.L.

i.L.

42.5

42.5

i.L.

i.L. 10.5

20

11.5

4

12.5

4.5

12.5

12.5

25

1.3 Baying system TS 8For modular front design Page 149

60

597/797

535/735

Cross-sections

vertical horizontal

i.L. = Clearance width

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 20: Baying systems TS 8 - Steven Engineering

Large enclosures

Industrial Enclosures

1187Rittal Catalogue 32/Industrial Enclosures

C

1.

Indu

stria

l Enc

losu

res

i.L. T3

3535 T7

H1

i.L. H

346

44

H2

3.5

4.5

42.5

35.5

77H

5

i.L. T5

T4

5551

25

T6 2

17

T1

12.5

1

3030

T2

6565

T1

49 699 49

i.L. 640Ø 1678.5

78.5

30 30

46.5

i.L. T

346

.5i.L. 712

67561 61

M12

1815

592 192

X34

0.5

93

90.52.

5

71

60

i.L. 455i.L. 455

475

735

797

22

Ø 9

M6

Ø 4.6

H9

H8

i.L. H

796

H6

H4

4 x

25

(= 1

00)

12.7

119

.1

25.

4 2

2.2

25.

4

7.1

14.3

1.3 Baying system TS 8 For isolator door locking Page 150

Model No. TSHeight dimensions mm Depth dimensions mm

H1 H2 H3 H4 H5 H6 H7 H8 H9 T1 T2 T3 T4 T5 T6 T7

8984.500 1805 1797 1712 1754 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335

8985.500 1805 1797 1712 1775 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435

8905.500 2005 1997 1912 1975 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435

8906.500 2005 1997 1912 1975 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535

Enclosure Note:The cut-outs in the right-hand trim piece are suitable for the following isolator actuators: Allen Bradley 1494 V-H11, Square D9422A1, ITE Siemens1) Max-Flex series/F HOH, General Electric TDA Type 1 and 2, Moeller NZM-XSHGVR12-NA. 1) Available in USA only.

H1 =H2 =H3 =

H4 =H5 =H6 =

H7 =

H8 =

H9 =

Overall height Height of rear panel Clearance between the enclosure frame Height of door and trim panelSection length of system punchings Distance between axes of the tubular door frame rows of holes Clearance between the tubular door frame Distance between the fastening bolts of the tubular door frame Distance from base to centre of lock

T1 =T2 =

T3 =T4 =T5 =T6 =

T7 =

Overall depth Section length of system punchings/distance between holes of base/plinth attachment Clearance between enclosure frames Depth of base frame Clearance of base opening Possible mounting depth (mounting plate assembly) Centre of lifting eye to centre of lifting eye

Only for TS 8906.5001

Detail X

i.L. = Clearance width

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com