bbv10 rashkin 1020

36
ENERGY STAR Qualified Homes Version 3: Assured Performance with Every Labeled Home ENERGY STAR TRAINING

Upload: bigbuilder

Post on 08-May-2015

875 views

Category:

Business


0 download

TRANSCRIPT

Page 1: Bbv10 rashkin 1020

ENERGY STAR Qualified Homes Version 3:

Assured Performance with Every Labeled Home

ENERGY STAR TRAINING

Page 2: Bbv10 rashkin 1020

ENERGY STAR QUALIFIED HOMES :

GROWTH

0

200000

400000

600000

800000

1000000

1200000

1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009

Column 1

Line 2

NumberLabeledHomes

Year

96 97 98 99 00 0302 04 05 06 0701 08 09

200,000

400,000

600,000

800,000

1,000,000

0

Cumulative

Annual

Page 3: Bbv10 rashkin 1020

0

5

10

15

20

25

2001 2002 2003 2004 2005 2006 2007 2008 2009

1

ENERGY STAR QUALIFIED HOMES:

GROWTH

% MarketPenetration

Year

Page 4: Bbv10 rashkin 1020

ENERGY STAR QUALIFIED HOMES METRICS:

BUILDER INTEREST

300

250

150

50

200

100

0Before Soft Market After Soft Market

~1,000% Growth!

Page 5: Bbv10 rashkin 1020

THE NEW NORMAL

Smaller Universe of Buyers– 75% Fewer Housing Starts– Tighter Credit = Less Qualified Buyers– Less Compelling Reasons to Buy

You Can’t Compete on Price– Massive Inventory of Fire-Sale Homes– Massive Inventory of Homes Under Water

High-Performance Train Has Left the Station– Energy Codes on Hyper Drive– Net-Zero Home Programs

A New Technology Change Everything– Hint, it Has Nothing to Do with Housing

Page 6: Bbv10 rashkin 1020

   

                        

   

           

The best thermal imager for the money.

                                 

LOW COST INFRARED CAMERAS

Page 7: Bbv10 rashkin 1020
Page 8: Bbv10 rashkin 1020

OBSOLETE COMPETITIONOBSOLETE COMPETITION

Page 9: Bbv10 rashkin 1020
Page 10: Bbv10 rashkin 1020
Page 11: Bbv10 rashkin 1020

WHY ENERGY STAR FOR HOMES SPECIFICATIONS CRITICAL

A voluntary labeling program that:

Defines Energy EfficientRigorous SpecificationsThird-Party Verified

Recognizes BuildersGovernment-Backed LabelWeb Site, Marketing, Awards

Page 12: Bbv10 rashkin 1020

PROBLEM: HOMES THAT FAIL

Control

Air Flow

ControlMoisture Flow

(Vapor, Bulk)

Control

Thermal Flow

AffordableComfortable

HealthyDurable

Page 13: Bbv10 rashkin 1020

SOLUTION: HOMES THAT WORK

Control

Air Flow

ControlMoisture Flow

(Vapor, Bulk)

Control

Thermal Flow

AffordableComfortable

HealthyDurable

Page 14: Bbv10 rashkin 1020

Control Moisture FlowVapor Bulk

Control Thermal Flow

Defining Energy Efficient

Control Air Flow

AffordableComfortable

HealthyDurable

Page 15: Bbv10 rashkin 1020

Control Moisture FlowVapor Bulk

Control Thermal Flow

Defining Energy Efficient

EfficientEquipment

Control Air Flow

AffordableComfortable

HealthyDurable

Page 16: Bbv10 rashkin 1020

Control Moisture FlowVapor Bulk

Control Thermal Flow

Defining Energy Efficient

EfficientEquipment

3rd PartyVerification

Control Air Flow

AffordableComfortable

HealthyDurable

Page 17: Bbv10 rashkin 1020

Control Moisture FlowVapor Bulk

Control Thermal Flow

EfficientEquipment

3rd PartyVerification

Control Air Flow

Air Sealing

Tight Ducts

Air Sealing

Tight Ducts

Air Sealing

Tight Ducts

Low-EWindows

EfficientHVAC

InsulationAlignment

Air Barriers

InsulataionR-Value

Air Barriers

EfficientWH System

EfficientLgtg./Appl.

Right-Sizing

Ventilation

Dehumid. inHot/Humid

InsulationInstallation

PressureBalancing

Min.ThermalBridging

HVACQuality Inst.

Water Man.Roofs

ThermalEnclos. Chk

HVAC Sys. QI Chks

Water Man.System Chk

AffordableComfortable

HealthyDurable

Air Barriers

Water Man.Walls

Defining Energy Efficient

Water Man.Found./Site

BuildingMaterials

ENERGY STAR

Version 3

Page 18: Bbv10 rashkin 1020

Control Moisture FlowVapor Bulk

Control Thermal Flow

EfficientEquipment

3rd PartyVerification

Control Air Flow

Air Sealing

Tight Ducts

Air Sealing

Tight Ducts

Air Sealing

Tight Ducts

Low-EWindows

EfficientHVAC

InsulationAlignment

Air Barriers

InsulataionR-Value

Air Barriers

EfficientWH System

EfficientLgtg./Appl.

Right-Sizing

Ventilation

Dehumid. inHot/Humid

InsulationInstallation

PressureBalancing

Min.ThermalBridging

HVACQuality Inst.

Water Man.Roofs

ThermalEnclos. Chk

HVAC Sys. QI Chks

Water Man.System Chk

AffordableComfortable

HealthyDurable

Air Barriers

Water Man.Walls

Defining Energy Efficient

Water Man.Found./Site

BuildingMaterials

ENERGY STAR

Version 3

Page 19: Bbv10 rashkin 1020

ENERGY STAR QUALIFIED HOMES VERSION 3

MAKING EXISTING HOMES OBSOLETE

70OF

Existing Home:• Thermal Enclosure Defects

Energy Star v3 Home:• Thermal Enclosure System

70OF

Page 20: Bbv10 rashkin 1020

ENERGY STAR QUALIFIED HOMES VERSION 3

MAKING EXISTING HOMES OBSOLETE

70OF

HVAC System

Existing Home:• Thermal Enclosure Defects• HVAC Min. Quality Installation

Energy Star v3 Home:• Thermal Enclosure System• HVAC Quality Installation

70OF

HVAC System

MRT MRT ControlControl

MRT MRT ControlControl√×

Page 21: Bbv10 rashkin 1020

ENERGY STAR QUALIFIED HOMES VERSION 3

MAKING EXISTING HOMES OBSOLETE

70OF

HVAC System

Existing Home:• Thermal Enclosure Defects• HVAC Min. Quality Installation• Water Management Parts

Energy Star v3 Home:• Thermal Enclosure System• HVAC Quality Installation• Water Management System

70OF

HVAC System

MRT MRT ControlControl

MRT MRT ControlControl√×

Page 22: Bbv10 rashkin 1020

ENERGY STAR QUALIFIED HOMES VERSION 3

PROGRAM REQUIREMENTS

MandatoryChecklists:

• Thermal Enclosure

• HVAC Quality Installation (2)

• Water Managed Construction

+

Ref. Design:[Performance or

Prescriptive*]

• Efficient Htg./Cooling

• Efficient Envelope

• Efficient Components

* Prescriptive Path only allowed for homes < Benchmark Home size

Page 23: Bbv10 rashkin 1020

ENERGY STAR QUALIFIED HOMES VERSION 3

PRESCRIPTIVE PATH* Ref. Design:

• Efficient Htg./CoolingEnergy Star or equiv. appropriate to

climate

• Efficient EnvelopeAir-Tight Construction (3 - 6 ACH50)2009 IECC Insulation LevelsRESNET Grade 1 Insulation InstallationEnergy Star Qualified Windows/Doors15% Window-to-Floor Area

• Efficient ComponentsTight DuctsProgrammable ThermostatEfficient Water HeaterEnergy Star Qualified Lighting/FansEnergy Star Qualified Appliances

* Prescriptive Path only allowed for

homes < Benchmark Home

size

Page 24: Bbv10 rashkin 1020

ENERGY STAR QUALIFIED HOMES VERSION 3

PERFORMANCE PATH

Size Adjustment

Factorx =FinalHERS IndexTargetScore

Initial HERS Index Target Score

Assumptions:

• Maximum 15% Glazing• Glazing Evenly Distributed

Reference Design Specifications

• Efficient Heating/Cooling• Efficient Envelope• Efficient Components

Page 25: Bbv10 rashkin 1020

Size Adjustment Factor not to exceed 1.0

Benchmark Home Size

CFA Benchmark Home 0.25 HERS Index

CFA Rated Home Target Score

ENERGY STAR QUALIFIED HOMES VERSION 3

SIZE ADJUSTED TARGET SCORE

BRs 1 2 3 4 5 6 7 8

CFA 1,000 1,600 2,200 2,800 3,400 4,000 4,600 5,200

xx

Page 26: Bbv10 rashkin 1020

ENERGY STAR QUALIFIED HOMES VERSION 3

SIZE ADJUSTMENT EXAMPLE

2,800 sf 4-BR benchmark home

5,000 sf 4-BR rated home

0.25

xx 78

= 67 ENERGY STAR HERS Index Target Score ==

5,000 sf, 4 BR Home with HERS Index Target Score of 78

Page 27: Bbv10 rashkin 1020

Thermal EnclosureSystem:•Air Leakage•Insulation R-Value•Insulation Installation•Air Barriers•Thermal Bridging•High-Perf. Windows

MANDATORY CHECKLISTS

Page 28: Bbv10 rashkin 1020

Thermal EnclosureSystem:•Air Leakage•Insulation R-Value•Insulation Installation•Air Barriers•Thermal Bridging•High-Perf. Windows

HVAC QualityInstallation System:•Efficient Equipment•Right-Sizing•Air Distribution•Refrigerant Charge•Duct Installation•Pressure Balancing•Ventilation•Filtration

MANDATORY CHECKLISTS

Page 29: Bbv10 rashkin 1020

Thermal EnclosureSystem:•Air Leakage•Insulation R-Value•Insulation Installation•Air Barriers•Thermal Bridging•High-Perf. Windows

Water ManagementSystem:•Roof Membranes•Flashing•WRB’s•Fabric Filters•Capillary Breaks•Drainage Layer

HVAC QualityInstallation System:•Efficient Equipment•Right-Sizing•Air Distribution•Refrigerant Charge•Duct Installation•Pressure Balancing•Ventilation•Filtration

MANDATORY CHECKLISTS

Page 30: Bbv10 rashkin 1020

THERMAL ENCLOSURE SYSTEMVALUE PROPOSITION

•Visibly better quality

•Superior comfort and health

•Future resale value

Page 31: Bbv10 rashkin 1020

6

7

8

9

10

11

12

13

14

11 12 13 14 15

Rated SEER

Typical Installation

HVAC SYSTEM QUALITY INSTALLATION

Fie

ld A

dju

sted

SE

ER

Courtesy of Advanced Energy Corp.

Page 32: Bbv10 rashkin 1020

6

7

8

9

10

11

12

13

14

11 12 13 14 15

Rated SEER

Typical Installation

Correct Flow 0.5Proper Charge 1.5

Sized Right .75Airtight Ducts 2.0

Courtesy of Advanced Energy Corp.

Fie

ld A

dju

sted

SE

ER

HVAC SYSTEM QUALITY INSTALLATION

Page 33: Bbv10 rashkin 1020

HVAC System Quality InstallationValue Proposition

Get What You Pay For Engineered Comfort

- Thermal Control- Humidity Control- Noise Control

Assured Fresh/Filtered Air

Page 34: Bbv10 rashkin 1020

Water Management SystemValue Proposition

Better protection for largest investment

Lower maintenance

Healthier home

Page 35: Bbv10 rashkin 1020

THE BUSINESS CASE:

RESPONDING TO NEW NORMAL

Attract Smaller Universe of Buyers

Male Price-Based Competition Obsolete

Exceed High-Performance Expectations

Bring on the Infrared Cameras

Page 36: Bbv10 rashkin 1020

HOW TO GET MORE INFORMATION

On the Web at:http://www.energystar.gov/homes