bcl2fastq2 for nextseq and hiseq x systems · • (optionally) samplesheet.csv. reminder: sample...
TRANSCRIPT
![Page 1: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/1.jpg)
© 2013 Illumina, Inc. All rights reserved.
Illumina, IlluminaDx, BaseSpace, BeadArray, BeadXpress, cBot, CSPro, DASL, DesignStudio, Eco, GAIIx, Genetic Energy, Genome Analyzer, GenomeStudio, GoldenGate, HiScan, HiSeq, Infinium,
iSelect, MiSeq, Nextera, NuPCR, SeqMonitor, Solexa, TruSeq, TruSight, VeraCode, the pumpkin orange color, and the Genetic Energy streaming bases design are trademarks or registered trademarks
of Illumina, Inc. All other brands and names contained herein are the property of their respective owners.
Bcl2fastq2 For NextSeq
and HiSeq X Systems
![Page 2: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/2.jpg)
2
By the end of this training you will:
– Know how to obtain bcl2fastq2
– Create a SampleSheet to be used by bcl2fastq
– Understand the bcl2fastq workflow for the NextSeq 500 and/or HiSeq X
– Be able to perform basic de-multiplexing troubleshooting
Session Objectives
![Page 3: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/3.jpg)
3
Download Bcl2fastq2
http://support.illumina.com/downloads/bcl2fastq_conversion_software.html
![Page 4: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/4.jpg)
4
Use IEM to create
Sample Sheet
Place Data on Analysis Server
Putty into Analysis Server
Run bcl2fastq2
View fastqfiles
Workflow
![Page 5: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/5.jpg)
5
Select Sequencer and Click Next
HiSeq X
Use IEM to create
Sample Sheet
Place Data on Analysis Server
Putty into Analysis Server
Run bcl2fastq2
View fastqfiles
NextSeq
![Page 6: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/6.jpg)
6
Select FastQ Only and Click Next
Use IEM to create
Sample Sheet
Place Data on Analysis Server
Putty into Analysis Server
Run bcl2fastq2
View fastqfiles
HiSeq X NextSeq
![Page 7: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/7.jpg)
7
Select Workflow Parameters
Use IEM to create
Sample Sheet
Place Data on Analysis Server
Putty into Analysis Server
Run bcl2fastq2
View fastqfiles
SampleSheet must be entered in reagent
barcode field in order for bcl2fastq2 to
recognize the sample sheet.
![Page 8: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/8.jpg)
8
Add Samples and Select Indices
Use IEM to create
Sample Sheet
Place Data on Analysis Server
Putty into Analysis Server
Run bcl2fastq2
View fastqfiles
![Page 9: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/9.jpg)
9
Exercise: Illumina Experiment Manager for
NextSeq
![Page 10: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/10.jpg)
10
Reviewing the Sample Sheet
Open in Excel immediately after
sample sheet creation within IEM
Review Sample Sheet on Linux Analysis Server
immediately before running bcl2fastq2
1) Navigate to run folder
2) Use command cat SampleSheet.csv to view
in terminal
![Page 11: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/11.jpg)
11
Analysis Server Requirements
Use IEM to create
Sample Sheet
Place Data on Analysis Server
Putty into Analysis Server
Run bcl2fastq2
View fastqfiles
NextSeq HiSeq X The BCL to FASTQ converter
needs the following input files :
• BCL files (*.bcl.bgzf) or (bcl.gz)
• *.bci files
• *.filter files
• *.locs or s.locs file
• RunInfo.xml file.
• (Optionally) SampleSheet.csv.
Reminder: Sample sheet
must be named SampleSheet.csv
![Page 12: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/12.jpg)
12
Use IEM to create
Sample Sheet
Place Data on Analysis Server
Putty into Analysis Server
Run bcl2fastq2
View fastqfiles
Open PUTTY.EXE
Enter your Server Details
Login to Server
Open Terminal Session on Analysis Server
![Page 13: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/13.jpg)
13
Use IEM to create
Sample Sheet
Place Data on Analysis Server
Putty into Analysis Server
Run bcl2fastq2
View fastqfiles
Invoke bcl2fastq in the following way:
1) Navigate to the root run folder by using the cd command
2) Use the command nohup /usr/local/bin/bcl2fastq
3) When process completes, command line reappears
A Few Helpful Linux Commands and options
Step 1
Steps 2 & 3
![Page 14: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/14.jpg)
14
Command Usage
cd To change directory
ls -alh Lists all files in directory in human readable format with sizes
cat Displays the contents of a file (use with small files)
zcat Displays the contents of a compressed file
Head [option] Shows the first specified number of lines in a file
cd .. Moves up one level in the directory structure
/usr/local/bin/bcl2fastq [options] Invokes bcl2fastq (See user guide for all available options)
A Few Helpful Linux Commands and Options
Options Usage
& Allows script to run in the background (placed at end of line)
nohup Closing the terminal session will not terminate process
![Page 15: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/15.jpg)
15
Use IEM to create
Sample Sheet
Place Data on Analysis Server
Putty into Analysis Server
Run bcl2fastq2
View fastqfiles
View Completed FastQ files
View FastQ directly on Linux system by
navigating to
Runfolder>Data>Intensities>BaseCalls*
*or location specified by option -- output-dir
View FastQ files in terminal by navigating to the
BaseCalls folder and using the command ls –alh
![Page 16: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/16.jpg)
16
Troubleshooting Demultiplexing
![Page 17: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/17.jpg)
17
Bcl2fastq2 Demultiplexing Scenarios
Is SampleSheet.csv present in run folder?
Or sample sheet does not contain [Data] Section
All reads placed in default Undetermined FASTQ files by lane
Are indexes provided in Sample sheet?
All reads placed in sample FASTQ files
Do reads match defined indexes?
Reads with no valid index placed in Undetermined_S0 FASTQ files
Reads with valid indexes placed in FASTQ files as defined in the sample sheet.
If project is defined in sample sheet, converter will
output fastq files to project folders
![Page 18: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/18.jpg)
18
Bcl2fastq2 Resources
C
Converter User Guide and Release
Notes available on website
http://support.illumina.com/downloads/
bcl2fastq_conversion_software.html
![Page 19: Bcl2fastq2 For NextSeq and HiSeq X Systems · • (Optionally) SampleSheet.csv. Reminder: Sample sheet must be named SampleSheet.csv. 12 Use IEM to create Sample Sheet Place Data](https://reader034.vdocuments.net/reader034/viewer/2022050323/5f7d0722a6e52f22162adba4/html5/thumbnails/19.jpg)
19
Questions?