bd bactec tm 9000 blood culture...

12
BD BACTEC TM 9000 Blood Culture System Unequaled Safety, Performance, Precision and Simplicity in Septicemia Testing

Upload: others

Post on 26-Apr-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

BD BACTECTM 9000Blood Culture SystemUnequaled Safety, Performance, Precision and Simplicity in Septicemia Testing

Page 2: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

The BACTECTM 9240 and 9120 blood culturetesting systems help improve diagnosis

and treatment and reduce health care costs bymaximizing laboratory efficiency, safety andproductivity.

Continuous Monitoring Technology• Patient samples are continuously monitored

every 10 minutes by the instrument to detectpositives as they occur, permitting earliersubculturing and diagnosis for betterpatient care.

• Advanced algorithms for low blood volume,pediatric specimens and slow-growingorganisms such as Haemophilus and

The BD BACTECTM 9240/9120 Blood Culture Systems

Neisseria provide rapid detection in bloodculture and extend delayed vial entrycapability.

• Automated built-in testing provides contin-uous quality control of every station every10 minutes, eliminating the need to performcomplicated calibration procedures toconform with U.S. Federal regulations.*

Noninvasive Design• The BACTEC 9000 Series is the only

truly noninvasive system, minimizing therisk to technologists: No bottle venting, nodangerous aerosols and reduced sharpshazard. No connectors or venting unitsrequired.

• No need for biohazard hoods or specialclothing.

• Exclusive BD VacutainerTM Safety-LokTM

adapter permits direct draw samplecollection, reducing the risk of needleexposure for medical personnel.

High Performance Results• Unique fluorescent sensor technology

enhances testing precision.• No other system has a shorter protocol or

a higher recovery rate than the BACTECBlood Culture System.

• Supports the complete line of BACTECMedia including standard, LYTIC, resin-based (including pediatric) and MYCO/FLYTIC for recovery of yeast, fungi andmycobacteria from blood. (Also supportsMycosis IC/F where available.)

The world’s most efficient andeconomical fully-automatedsystems for septicemia testing.

1

2

3

4

5

6

7

8

9

10

Page

Page 3: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

Simple Operation• Bar code scanning provides easy step-by-

step instructions for rapid bottle entry andtest initiation.

• Bi-directional LIS interface permits directdownload of patient information, elimi-nating 90% of keystrokes and enablingpersonnel on all shifts with differing levelsof experience to master data/bottle entryquickly—reducing labor and improvingtime to results.

• Positive results are automatically flaggedevery 10 minutes for quick processing.Negative bottles can be batch scanned outof the system and unloaded at the end ofthe protocol.

• Up to 50 BACTEC Blood Culture andMycobacteria Instruments can be networkedtogether through the EpiCenterTM DataManagement System for easy use in largelaboratories.

EpiCenterTM Data ManagementSystem• Network integration with all BD instruments• Bi-directional LIS interface with host query• Customizable reporting with full graphics

capabilities• Off-line test entry and result reporting• Advanced query writer with batch results

reporting• User configurable capabilities

Service and Support• Regional Sales Support Specialists are

available for on-site customer training as required.

• Technical Service and Customer ServiceRepresentatives are trained to provide in-depth customer support.**

H E A L T H C A R E S O L U T I O N S T H R O U G H M I C R O B I O L O G Y

* US CLIA ‘88** Call your local BD representative/office for service and support in your area.

1

2

3

4

5

6

7

8

9

10

▲▲

Page

9240/91209240/9120

Page 4: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

The BACTEC 9050 Blood Culture Systemcombines the features of the BACTEC

System into a smaller instrument for laboratoriesprocessing fewer than 5 blood cultures per day.

Continuous Monitoring Technology• Patient samples are continuously monitored

every 10 minutes by the instrument todetect positives as they occur, permittingearlier subculturing and diagnosis forbetter patient care.

• Advanced algorithms for low bloodvolume, pediatric specimens andslow-growing organisms such asHaemophilus and Neisseriaprovide rapid detection in bloodculture and extend delayed vialentry capability.

The BD BACTECTM 9050 Blood Culture System

• Automated built-in testing providescontinuous quality control of every well,every 10 minutes, eliminating the need to perform complicated calibrationprocedures. Complies with CLIA ‘88regulations in the U.S.A.

Noninvasive Design• The BACTEC 9000 Series is the only

truly noninvasive system, minimizing therisk to technologists: No bottle venting,no dangerous aerosols and reducedsharps hazard. No connectors or ventingunits required.

The benefits of the larger BACTECTM Systems in a convenient size for the lower-volume laboratory.

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

7

8

9

10

Page

Page 5: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

• No need for biohazard hoods or specialclothing.

• Exclusive BD Vacutainer Safety-Lokadapter permits direct draw samplecollection, reducing the risk of needleexposure for medical personnel.

High Performance Results• Unique fluorescent sensor technology

enhances testing precision.• No other system has as short a protocol

or as high a recovery rate as the BACTECBlood Culture System.

• Supports the complete line of BACTECMedia including standard, LYTIC, resin-based (including pediatric) and MYCO/FLYTIC for recovery of yeast,fungi and mycobacteriafrom blood.

Simple Operation• Fixed bar code reader minimizes user

interaction.• Liquid crystal display with operator soft

keys simplifies operation.• Removal of positives.• Removal of negatives.• Printing of patient reports.• Bottle status display features a graphic

representation of all instrument and bottleconditions.

• Positive results are automatically flaggedevery 10 minutes for quick processing.

• No external computer to occupy valuablecounter space or complicate operations.

H E A L T H C A R E S O L U T I O N S T H R O U G H M I C R O B I O L O G Y

1

2

3

4

5

6

7

8

9

10▲1

2

3

4

5

6

7

8

9

10

▲ Page

90509050

Page 6: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

Media is the heart of the BACTECSystem, offering superior performance

with the widest range of media choices.

BACTEC PLUS Media• PLUS aerobic, anaerobic and pediatric

media demonstrate unmatched recovery of pathogens from blood.

• Exclusive resin component effectivelyneutralizes a wide variety of antibiotics,allowing growth of microorganisms thatwould not occur in conventional media.

BD BACTECTM Media

• Increased recovery facilitates a moreaccurate diagnosis and effective treatment,leading to shorter hospital stays, lowerpatient costs and greater overall efficiency.

• Peds PlusTM medium permits excellentrecovery of organisms from smallerpatient samples usually associated withpediatric patients.

BACTEC LYTIC/10 Anaerobic Medium• Lysing agent increases detection of organisms

partially phagocytized by white blood cells.• Provides faster time to detection for

facultative and anaerobic organisms.• Superior recovery rates and time to detec-

tion compared to standard anaerobic media.• Capitalizes on BACTEC System software

algorithms to increase the frequency ofearly detection and diagnosis.

The heart of the BACTECTM

System.

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

7

8

9

10

Page

Page 7: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

BACTEC Standard Media• Provides suitable growth media for all

types of bacteria and yeast.• Superior performance compared to

standard conventional media used inmanual blood culture systems.

• Offers the lowest cost alternative of allmedia choices without compromisingquality.

BACTEC MYCO/F LYTIC Medium• Simple whole blood procedure saves

valuable time, labor, materials and costs,while reducing the risks associated withhandling potentially contaminated blood.

• Recovers more yeast, fungi and myco-bacteria faster than solid media at thelowest cost-per-test.

• Simplifies ordering and inventorying byproviding superior detection of all threemicroorganism groups (including H.capsulatum) with a single test.

• Lysing agent increases detection of organismspartially phagocytized by white blood cells.

BACTEC TM Introduces Blood CultureProcedural TraysNow the hospital’s best choice for safer, morecost-effective and standardized blood collectionand blood culture procedures is the BACTECBlood Culture Procedural Tray. Trays includethe Vacutainer Brand Safety-Lok Blood Collec-tion Set, Standard Needle Holder, and newPersistTM Skin Prep Swabs which apply in onestep and dry in 30 seconds.

• Increase recovery of pathogens• Provide a capitated supply cost• Reduce specimen contamination• Increase labor efficiency and shorten workflow• Enhance cost avoidance and improve

reimbursement potential• Reduce stock loss using a standardized

system• Improve healthcare worker’s safety

Choose from three tray configurations:• Adult Tray 1—includes BACTEC PLUS

Aerobic/F & LYTIC/10 Anaerobic/F media• Adult Tray 2—features BACTEC

Standard/10 Aerobic/F & StandardAnaerobic/F media combination

• Pediatric Tray 3—features BACTECPeds Plus medium, designed for use withchildren or where low blood volumespecimens are anticipated

H E A L T H C A R E S O L U T I O N S T H R O U G H M I C R O B I O L O G Y

1

2

3

4

5

6

7

8

9

10▲1

2

3

4

5

6

7

8

9

10

▲ Page

MediaMedia

Page 8: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

The EpiCenterTM Data Management System

A companion workstation designed to provideadvanced workflow and custom reporting fornetwork integrated BD instruments.

1

2

3

4

5

6

7

8

9

10

The BDProbeTec™ ET system offers an amplifiedSDA probe assay for C. trachomatis andC. trachomatis/N. gonorrhoeae, M. tuberculosisCulture ID Test* and Direct MTB Test.

Phoenix™ 100 Automated Identificationand Susceptibility System, the new choicein automated microbiology.

LIS(Laboratory Information System)

1

2

3

4

5

6

7

8

9

10

Page

Page 9: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

H E A L T H C A R E S O L U T I O N S T H R O U G H M I C R O B I O L O G Y

* M. tuberculosis Culture ID Test not available in the United States.

1

2

3

4

5

6

7

8

9

10▲

BACTEC™ MGIT™ 960 automatedmycobacteria growth and detection system.

BACTEC™ 9000 Blood Culture System,the efficient, economical and fully automated system for detecting bloodstream infections.

1

2

3

4

5

6

7

8

9

10

▲ Page

Data ManagementData Management

Page 10: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

The BD BACTEC Data Management Systemsupports the enhanced capabilities of the

BACTEC 9000 System instruments. Choose from four levels of data management to simplyand effectively harness the BACTEC System’sfull potential.

Level IThe BACTEC 9000 System with bar code iconinterface:• Increases workflow• Monitors instrument status• Tracks and reports in-protocol specimens

Level IILevel I plus:• LIS connectivity to all interfaces written to

ASTM standards• Bi-directional capability to download patient

demographics directly to core system computer

The BD BACTECTM Data Management System

• Saves valuable technologist time, speedsreporting of results

• Records patient demographics andspecimen results

Level III—BACTEC VISIONLevel II plus: extended data management• Local Area Network (LAN) capability• Bi-directional LIS connectivity following

ASTM protocols• Consolidates patient and specimen demo-

graphics for enhanced reporting options• Query launcher which permits user-defined

queries for customized reports

Level IV—EpiCenter DataManagement SystemLevel III plus: advanced data managementcapabilities• The EpiCenter System is a companion

workstation designed to provide advancedworkflow and custom reporting for net-work integrated BD instruments.

• Customizable reports with full graphicalcapabilities track isolate source, recoverycomparisons by media type, contamina-tion rates and trends—all with the abilityto export or print findings.

• Bi-directional interfaces with all LIS systemsand the capability to write to ASTMstandards eliminate duplicate data entryfor important patient demographic andtest information.

• The powerful DataView module opens upthe entire EpiCenter database to userdefined queries—limited only by the user’simagination.

Power and flexibility to addressevery laboratory’s unique information strategy.

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

7

8

9

10

Page

Page 11: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

H E A L T H C A R E S O L U T I O N S T H R O U G H M I C R O B I O L O G Y

1

2

3

4

5

6

7

8

9

10▲1

2

3

4

5

6

7

8

9

10 ▲ Page

BACTEC TM 9000 System Specifications

Requirement BACTECTM 9240 BACTECTM 9120 BACTECTM 9050

Height 37 in. (93.98 cm.) 24 in. (60.96 cm.) 28.5 in. (72.39 cm.)

Width 51 in. (129.54 cm.) 51 in. (129.54 cm.) 24.0 in. (60.96 cm.)

Depth 22 in. (55.88 cm.) 22 in. (55.88 cm.) 25.5 in. (64.77 cm.)

Weight 680 lbs. (308.45 kg.) 450 lbs. (204.12 kg.) 100 lbs. (45.36 kg.)

Temperature 68˚F to 86˚F (20˚C to 30˚C) 68˚F to 86˚F (20˚C to 30˚C) 65˚F to 89˚F (18.3˚C to 31.1˚C)

Humidity (relative) 10% to 85% 10% to 85% 10% to 90%

Input Voltage 115v/220v/±10% 115v/220v/±10% 115v/220v/±10%

Input Current 10 amps max 10 amps max 2.5 amps max

Input Line Frequency 50/60Hz ± 3 Hz 50/60Hz ± 3 Hz 50/60Hz ± 3 Hz

BACTEC TM 9000 System Configurations

Requirement 9120 w/Stand 9240 w/Stand 9120/9240 w/Stand 9240/9240 w/Stand

Height 55 in. (139.7 cm.) 68 in. (172.72 cm.) 66 in. (167.64cm.) 79 in. (200.66 cm.)

Width 58 in. (147.32 cm.) 58 in. (147.32 cm.) 58 in. (147.32 cm.) 58 in. (147.32 cm.)

Depth 27 in. (68.58 cm.) 27 in. (68.58 cm.) 27 in. (68.58 cm.) 27 in. (68.58 cm.)

Configurations & SpecificationsConfigurations & Specifications

Page 12: BD BACTEC TM 9000 Blood Culture Systemtrustgulf.com/bainounah/files/Ktlujat/BD/Bactec_brochure... · 2011-03-31 · manual blood culture systems. • Offers the lowest cost alternative

BD BiosciencesBecton, Dickinson and Company7 Loveton CircleSparks, MD 21152-0999 USATel: 800.638.8663www.bd.com/biosciences/diagnostic

2771 Bristol CircleOakville, OntarioCanada L6H 6R5Tel: 800.268.5430

Monte Pelvoux 111, 9th FloorCol. Lomas de Chapultepec 11000 México D.F.Tel: 52.5.237.1200

11 rue Aristide Bergès38800 Le Pont de Claix, FranceTel: 33.4.7668.3636

Akasaka DS Building5-26 Akasaka 8-chomeMinato-kuTokyo, 107-0052 JapanTel: 81.24.593.5405

30 Tuas Avenue 2Singapore 639461Tel: 65.8610.633

Rua Alexandre Dumas 197604717-004 São Paulo, S.P. BrazilTel: 55.11.5185.9833

BACTEC, BD, BDProbeTec, EpiCenter, Logo, MGIT, Persist, Peds Plus, Safety-Lok and Vacutainer are trademarks of Becton, Dickinson and Company. ©2000.

Windows and Microsoft Access are registered trademarks of Microsoft Corporation.

0-2451 June 2000 Printed in the USA