BDS Design Studies. John Amann ILC Mechanical Engineering 10/24/06. BDS Alcove Layout 4.5m x 6m x 3m. Instrumentation/Control/Vacuum Racks. Rack Mounted Power Supplies. Freestanding 800kW Power Supply. Amann 10/24/06. PDL1 Area 4m Service Tunnel. .75m Cable Penetration. 20m Section. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: BDS Design Studies

BDS Design Studies

John Amann

ILC Mechanical Engineering

10/24/06

Page 2: BDS Design Studies

Amann 10/24/06

BDS Alcove Layout4.5m x 6m x 3m

Freestanding 800kW Power Supply

Rack Mounted Power Supplies

Instrumentation/Control/Vacuum Racks

Page 3: BDS Design Studies

Amann 10/24/06

PDL1 Area 4m Service Tunnel

3.25m floor

.75m Cable Penetration

High Density of Power Supplies20m Section

23 Freestanding PS

15 Rack Mount PS

Page 4: BDS Design Studies

Amann 10/24/06

4m Service Tunnel Installation Issues?

350kW Power Supply Fits

Page 5: BDS Design Studies

Amann 10/24/06

Tunnel Pocket to Accommodate 800kW PS

4m Service Tunnel

4m BDS Tunnel

Clearance Around Racks and PS

Cable Tray

800kW PS

Tunnel Pocket

Need 2 Total for BDS1 for Each BSY

Page 6: BDS Design Studies

Amann 10/24/06

Push Pull IR25m x 100m x 30m

Page 7: BDS Design Studies

Amann 10/24/06

Push Pull IR(Cavern Hidden)

GLD Sized Detector

Mobile Shield Wall

Mobile Platform20m x 30m Electronics/Cryo Shack

1m Shielded

Page 8: BDS Design Studies

Amann 10/24/06

Mobile Shield Wall HalfSteel Reinforced Concrete

3m Thickness

9m Base

Interference with Service Tunnel Opening

25m Height

Structural Rib

Overlapping Rib

Page 9: BDS Design Studies

Amann 10/24/06

Pac Man For BDS Tunnel

Recessed Niche Pac Man Open

Pac Man Closed

Can not locate Pac Man on IR wall.Not enough clearance to open and close.Solution: Create Recessed Niche

Page 10: BDS Design Studies

Amann 10/24/06

Asymmetrical Pac Man

Beam Line Support Here Minimize Unsupported Span~3m

Still need to think about Pac Man “snout” to span IR wall to detector.Should it be integrated into detector?

Detector

Pac Man

Page 11: BDS Design Studies

Amann 10/24/06

IR Concrete Floor DeformationExtreme Case 20,000psi

Max Y Displacement = .6mm

From CMS/ATLAS experience,need 5cm thick steel plates on IR Floor to prevent cracking.

Page 12: BDS Design Studies

Amann 10/24/06

Work in Progress……

-Design of beam line breaking point/location of SC magnets.

-Design of Pac Man snout to enclose breaking point.

-Air caster modules for mobile platform and shield wall.

-Service tunnel entrance/access from IR.

-More detailed IR floor deformation studies.