behrmann_brooke medical offices id 312 fall 2016
TRANSCRIPT
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
12/1
2/20
15 7
:52:
36 P
M
ID-1.00
COVER SHEET
CheckerAuthor
Dec.18 2015Art Institute of Houston
3 PAIR BUTTS
1 EACH LATCHSET3 PAIR BUTTS
1 EACH LOCKSET1 EACH SURFACE MOUNTED CLOSER
1 EACH DOOR STOP
1 EACH DOOR STOP (FLOOR MOUNTED)
SET "A"
SET "B"
1.
3.
2.
6.
5.
4. ALL DOOR FRAMES TO HAVE BUILDING STANDARD SILENCERS.
REFER TO DOOR SCHEDULE FOR HARDWARE COMBINATIONS.
ALL DOUBLE DOORS ARE TO HAVE DUMMY HARDWARE ON THE INACTIVE LEAF.
ALL DOORS TO BE UNDERCUT 5/8" FOR CARPET CLEARANCE.
ALL DOORS, HARDWARE AND FRAMES ARE TO BE BUILDING STANDARD UNLESS NOTED OTHERWISE.
ALL DOORS IN FIRE RATED WALLS SHALL HAVE HARDWARE AS REQUIRED TO MEET FIRE RATINGS.
DOOR HDWR. COMBINATIONS
DOOR NOTES
MULLION
MANUFACTURER
MINIMUM
HORIZONTALINFORMATION TO FOLLOW
AMPEREABOVE FINISHED FLOOR
CENTER LINE
CEILING
COLUMN
CASED OPENING
H.V.A.C.
HORZ.I.T.F.
MIN.
MFR.
MUL.
OVER HEAD DOOR
NOT IN CONTRACTON CENTER
TELEPHONE BOARD
REFRIGERATOR
SOLID CORE
REQUIRED
SECTION
VERIFY IN FIELD
WITH
VOLT
WITHOUT
VERTICAL
VINYL COMPOSITION TILE
UNLESS NOTED OTHERWISE
STAINLESS STEEL
TB
DOOR
DRAWING
CONTRACTOR
EQUAL
ELEVATIONELECTRICAL PANEL
ELECTRIC WATER COOLER
ELECTRICAL
W/
V.
GUAGE
FINISH
FIRE HOSE CABINET
FIRE EXTINGUISHER CABINET
HARDWARE
HOLLOW METAL
GYSUM BOARD
GLASS
O.H. DOOR
REF.
O.C.N.I.C.
REQD.
SECT.
S.S.
U.N.O.
S.C.
V.C.T.
V.I.F.
VERT.
W/O
CONTINUOUS
AMP.A.F.F.
CL
CLG.
COL.
C.O.
DR.CONTR.
DWG.
EP
E.W.C.
ELEV.
EQ.
ELEC.
GA.
FIN.
F.H.C.
F.E.C.
HDWR
GYP. BD.
H.M.
GL.
CONT.
ABBREVIATIONS
WATER HEATER
HEATER
WH
HTR.HT. HEIGHT
WD. WOOD
1.
3.
2.
4.
5.
7.
FABRICATION.
6.
9.
10.
CONTRACTOR.
11.
12.
8.
13.
CONTRACTOR.
15.
14.
16.
17.
DEFECTIVE.
19.
OF THE WORK.
20.
18.
DESIGNER PRIOR TO INSTALLATION (TO BE INCLUDED IN BASE BID OF CONSTRUCTION)COORDINATE HOLES FOR PLUMBING CLEANOUTS AND ACCESS PANELS WITH INTERIOR
TO PROCEEDING WITH THE WORK.
COORDINATE IN ALL PORTIONS OF THE WORK.
BEHIND, UNLESS NOTED OTHERWISE.
PERMITS AND CERTIFICATES OF OCCUPANCY.
HOURS OF OPERATION, ETC.
ALL CONSTRUCTION TO BE IN COMPLIANCE WITH LEGAL AND LOCAL CODES.
SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL
OPENED WITHOUT THE USE OF A KEY FROM THE SIDE FROM WHICH EGRESS IS MADE.
ALL CUSTOM CABINET WORK TO BE FURNISHED, DELIVERED, AND INSTALLED BY THE CABINET
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES: AND SHALL
THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE CONTRACTOR'S BEST
ALL DOORS USED IN CONJUNCTION WITH EXITS, SHALL BE SO ARRANGED AS TO BE READILY
WHERE DROPPED FASCIA IS INDICATED, GYPSUM BOARD SOFFIT IS TO BE RETURNED TO WALL
CONTRACTOR TO COORDINATE REQUIREMENTS WITH MILLWORKERS.
DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN.
PARTITIONS SHALL BE DIMENSIONED FROM FINISH TO FINISH, UNLESS NOTED OTHERWISE.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON AT THE JOB SITE
GENERAL CONTRACTOR SHALL REMIT ALL REQUIRED SHOP DRAWINGS (1 SET OF REPRODUCIBLES
CONTRACTOR FOR THE PROJECT SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING
AND SHALL NOTIFY INTERIOR DESIGNER OF ANY ERROR, INCONSISTENCY OR OMMISIONS PRIOR
ALL MILLWORK, BLOCKING, GROUNDS, ROUGH BUCKS, AND MISCELLANEOUS BLOCKING TO BEU.L. APPROVED NON-COMBUSTIBLE MATERIAL IN ACCORDANCE WITH LOCAL MUNICIPAL CODES.
GENERAL CONTRACTOR TO COORDINATE WITH INTERIOR DESIGNER IN REGARD TO BUILDING
AND 1 SET OF BLUE LINE PRINTS) TO INTERIOR DESIGNER FOR APPROVAL PRIOR TO
AT THE TIME OF CONSTRUCTION.
ANYONE NOT SKILLED IN THE TASK ASSIGNED THEM.
PROPER EXECUTION AND COMPLETION OF THE WORK.
WITH THE CONTRACT DOCUMENTS. ALL WORK NOT CONFORMING TO THESE REQUIRMENTS,
THE CONTRACTOR WARRANTS TO THE OWNER THAT ALL MATERIALS AND EQUIPMENT
THE WORK OR PORTIONS THEROF PROVIDED BY THE CONTRACTOR WHICH ARE LEGALLY ENACTED
FURNISHED UNDER THIS CONTRACT WILL BE NEW UNLESS OTHERWISE SPECIFIED, AND THAT ALL
INCLUDING SUBSTITUTIONS NOT PROPERLY APPROVED AND AUTHORIZED, MAY BE CONSIDERED
THE CONTRACTOR SHALL PAY ALL SALES, CONSUMER, USE AND OTHER SIMILAR TAXES FOR
WORK WILL BE OF GOOD QUALITY, FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE
ANY OTHER PERSONS PERFORMING ANY OF THE WORK UNDER A CONTRACT WITH THE
UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL
AND MACHINERY, TRANSPORTATION, AND OTHER FACILITIES AND SERVICES NECESSARY FOR THE
THE CONTRACTOR SHALL AT ALL TIMES ENFORCE STRICT DICIPLINE AND GOOD ORDER AMONGTHE CONTRACTOR'S EMPLOYEES AND SHALL NOT EMPLOY ON THE WORK ANY UNFIT PERSON OR
PROVIDE AND PAY FOR ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT
THE CONTRACTOR'S EMPLOYEES, SUBCONTRACTORS AND THEIR AGENTS AND EMPLOYEES, AND
IN NO WAY RELIEVE THE CONTRACTOR FROM ANY OBLIGATION IN RESECT TO THEIR WORK.
THE CONTRACTOR WILL BE PRESUMED TO HAVE INSPECTED THE SITE AND TO HAVE READ AND
REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE PERFORMANCETHE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES,
OR OMISSION OF ANY CONTRACTOR TO EXAMINE ANY FORM, INSTRUMENT OR DOCUMENT SHALLTO BE THOROUGHLY FAMILIAR WITH PLANS, SPECIFICATIONS, AND DOCUMENTS. THE FAILURE
THE CONTRACTOR SHALL BE RESPONSIBLE TO THE OWNER FOR THE ACTS AND OMISSIONS OF
GENERAL NOTES
1 3D 3/4 VIEW
2 3D BUILDING
LOUIS ARRIOLAID 312 ADVANEDCONSTRUCTION
DOCUMENTSFALL 2016
No. Description Date
ID-3.00
ENLARGED PLANS AND ELEVATIONS
XXXX
X
REVIS
ION #
3
REVIS
ION #
2
REVIS
ION #
1
ORI
GIN
AL IS
SUE
DRAWING NAME
THIRD FLOOR
THIRD FLOOR POWER PLAN
COVER SHEET/GENERAL NOTES
BUILDING SECTIONS
EXTERIOR ELEVATIONS (N/E)
THIRD FLOOR FURNITURE PLAN
THIRD FLOOR RCP PLAN
REVIS
ION #
4
DWG. NO.
ID-5.00
ID-1.00
ID-1.03
ID-1.01
ID-2.00
ID-1.02
ID-1.04
ORIGINAL ISSUE
REVISED AND REISSUE OF ORIGINAL DRAWINGS
REVISED AND ISSUED ON 8 1/2" X 11" SHEET (S)
INDEX OF DRAWINGS
SCHEDULES AND DIAGRAMSID-6.00
3D VISUALIZATION
DETAILS
ID-4.00
APPROVAL SIGNATURE DATE OF SIGNATURE
ID-9.01
ROOM LEGENDNFC-1
ID-9.003D VISUALIZATION
ID-2.00
1
ID-2.002
-
-
-
-
2ID-3.00
A
A
G
A
A
A A A
A
C
A
A
A
B
B
445 SF
CONFERENCEROOM
111211 SF
KITCHEN110
66 SF
BATHROOM105
165 SF
WOMEN PUBLICRESTROOM
49165 SF
MEN PUBLICRESTROOM
48
665 SF
LOBBY103
47 SF
CLOSET108
341 SF
COPY ROOM127
182 SF
DOCTOR'SOFFICE A
112331 SF
APARTMENT113
208 SF
EXAM ROOM D114
182 SF
EXAM ROOM C115
232 SF
DOCTOR'SOFFICE B
116
167 SF
EXAM ROOM B117
162 SF
EXAM ROOM A118
779 SF
RECEPTION A119
270 SF
KITCHEN120
266 SF
LOUNGE121
201 SF
OFFICE C122
161 SF
OFFICE B123
178 SF
OFFICE A124
1135 SF
OFFICE STATIONS125
166 SF
STORAGE126
A
A
A AA A A
ID-4.002
ID-4.003
VVVV
C
C
B
RECEPTION B130
LOUNGE A131
1ID-3.00
ID-4.004
8' - 11 1/4" 9' - 5 3/4" 13' - 0" 10' - 3 1/4"
18' -
6"
18' -
6"
13' -
10"
25' -
3"
7' - 4 3/4"
18' -
8 1
/2"
10' -
11
3/4"
10' -
9 1
/4"
16' -
3 1
/2"
18' -
1 3
/4"
9' -
1"
3' -
10"
19' -
8 1
/4"
16' -
9 1
/2"
25' -
10
1/4"
17' -
0 1
/2"
45' - 8 1/4"
19' -
3 1
/2"
87.81
°
90.00
°
14' -
0"
2' - 0"
2' -
0"2'
- 0"
13' - 6 1/4" 17' - 5" 10' - 5 1/2" 16' - 6 1/2" 5' - 9 3/4" 19' - 7 1/2" 13' - 3 1/2" 13' - 3 1/4" 12' - 1" 14' - 8 1/2"
3' -
11 3
/4"
5' - 0"
1' -
10 3
/4"
9' - 8 1/4"9' - 5 3/4"
3' - 0"
8' - 6 1/4"
3' - 6"
50.61°
50.77°
90.00°
ID-4.00
6
ID-4.00 9
ID-4.00 5
ID-4.008
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
3/16" = 1'-0"
12/1
2/20
15 7
:53:
35 P
M
ID-1.01
THIRD FLOOR
CheckerAuthor
Dec.18 2015Art Institute of Houston
ARCHITECTURAL NOTES
1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO PRICING AND CONSTRUCTION.
2. CONTRACTOR SHALL PROVIDE AND INSTALL BLOCKING AS REQUIRED IN ALL WALLS WITH NEW SHELVING AND MILLWORK.
3. ALL DOORS ARE TO HAVE 6" RETURNS UNLESS NOTED OTHERWISE.
150 SF
Room name
101
DRAWING NUMBER
SHEET NUMBERA101
1DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
EXTERIOR ELEVATION (NORTH, SOUTH, EAST, OR WEST)
TRANSVERSE OR LONGITUDINAL SECTION FLAGS
NORTH ARROW
DOOR TAG (REFER TO DOOR SCHEDULE)ENLARGED PLAN CALLOUT AREA
ROOM / AREA TAG
FLOOR PLAN SYMBOL LEGEND
SIM
A1011
SIM1
A101
1t WINDOW TAG (REFER TO WINDOW SCHEDULE)
3/16" = 1'-0"1 THIRD FLOOR PLAN
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
DOOR SCHEDULE
Type Mark CountFamily and
Type Width Height Description
A 19 3' - 0" 7' - 0"B 3 Single-Glas
s 1: 36" x84"
3' - 0" 7' - 0" SINGLE-GLASS
C 3 Double-Glass 1: 72" x84"
6' - 0" 7' - 0" DOUBLE-GLASS
G 1 Double-Flush: 72" x 84"
6' - 0" 7' - 0"
VVVV 1 Single-Panel 4: 36" x84"
3' - 0" 7' - 0"
Grand total: 27
1 1 1 1
1 11 1
3333
3333
CLOSET108
KITCHEN110
CONFERENCEROOM
111
DOCTOR'SOFFICE A
112
APARTMENT113
RECEPTION A119
EXAM ROOM A118
EXAM ROOM B117
DOCTOR'SOFFICE B
116
EXAM ROOM C115
EXAM ROOM D114 LOBBY
103
STORAGE126
WOMEN PUBLICRESTROOM
49
MEN PUBLICRESTROOM
48 COPY ROOM127
KITCHEN120
LOUNGE121
OFFICE STATIONS125
OFFICE A124
OFFICE B123
OFFICE C122
2515
25
1720 18
1
1
6
32
23
16
16 16
16
29 29
29
23
23
23
11
11
9 9 9
14
21 21
2
1
21 21
7
29
26
22
22
24
22
22
22
15
30
27
30
26 26 26 26? ??
?
1
1
1
1
1
1
1
32
3233
33
29
6
13
29 29
7
15
3233
7
29 29
15
32
23
33
29
6
27
33
27
6
13 6
10
?
2525
32
9
9
919
24
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
3/16" = 1'-0"
12/1
2/20
15 7
:54:
13 P
M
ID-1.02
THIRD FLOORFURNITURE PLAN
CheckerAuthor
Dec.18 2015Art Institute of Houston
2.
1.
3.
4.
5.
6.
OTHERWISE.
8.
7.
9.
T.A.S. REGULATIONS.
WHERE INDICATED, ROD AND SHELF TO HAVE SEMI-GLOSS ENAMEL PAINT APPLIED TO MATCH ADJACENT WALLS.
BY BUILDING OFFICIALS, APPLY FLAMEPROOFING TO FABRIC WALLCOVERINGS.
ALL TRIM AND DETAILING TO CONFORM WITH BUILDING STANDARD QUALITY LEVELS UNLESS NOTED
ALL WALLCOVERINGS TO BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS FOR THEPARTICULAR SURFACE APPLICATION, INCLUDING TEMPERATURE AND DUST CONTROL. REFER TOSHEET "FX" FOR SPECIAL NOTE REGARDING WALLCOVERING YARDAGE.
INSPECT DRYWALL AND VERIFY THAT CONDITIONS ARE SUITABLE FOR THE APPLICATION OF
ALL INTERIOR FINISH MATERIALS TO BE IN COMPLIANCE WITH LOCAL CODES. WHEN REQUIRED
ALL PAINT SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS FOR
CONTRACTOR TO NOTIFY INTERIOR DESIGNER OF ANY SURFACES NOT HAVING A FINISH
THE PARTICULAR SURFACE, 2 COAT MINIMUM APPLICATION IS REQUIRED.
MEET. RUBBER STRIP COLOR TO MATCH BASE COLOR. THRESHOLD HEIGHT TOLERANCE TO MEETPROVIDE RUBBER STRIP THRESHOLD AT ALL POINT WHERE CARPET AND RESILIENT FLOORING
CONTRACTOR TO SUBMIT 8" X 8" GYPSUM BOARD SAMPLE OF ALL PAINT FINISHES TO INTERIORDESIGNER FOR APPROVAL.
WALLCOVERINGS PRIOR TO INSTALLATION.
SPECIFICATION PRIOR TO SUBMITTING A BID. REFER TO SHEET "FX" FOR SPECIAL NOTE.
FINISH NOTES
FURNITURE SCHEDULE
Type Mark Family and Type Count
121 Haworth_Chair_Very-Perforated Conference: Arms 182 Dining_Table_w_2Chair - Copy: 762 mm x 1525 mm 13 Modern_Office_Desk_8428:
Modern_Office_Desk_84288
6 Sofa-Corbu: Sofa 57 Chair-Task Arms: Chair-Task Arms 39 Armchair_-_Crescent: Armchair_-_Crescent 610 Steelcase Coalesse - Circa - Seating - Round
Ottoman: Ottoman1
11 Ricoh_copier_14254 (1): Ricoh_copier_14254 (1) 213 Table-Coffee: 24" x 24" x 24" 214 Corporate_Desk_-_Designer_Series_11327:
Corporate_Desk_-_Designer_Series_113271
15 Credenza_1066: Credenza_1066 416 Chair-Corbu: Chair 417 HighTower_Arroyo_Bench: HighTower_Arroyo_Bench 118 blaise_sofa_6129: blaise_sofa_6129 119 Coffee_table_10605: Coffee_table_10605 120 6_Drawer_Dresser_12521: 6_Drawer_Dresser_12521 121 Medical_scale_bascula_medica_11736:
Medical_scale_bascula_medica_117364
23 File_Cabinet_1024: File_Cabinet_1024 624 Archipelago_Table_Ø85_H35:
Archipelago_Table_Ø85_H351
25 Gus_Modern_Return_Bench_10855:Gus_Modern_Return_Bench_10855
4
26 Tinto_Center_Easy_Chair: Tinto_Center_Easy_Chair_ 427 Coffee_Table_13936 - Copy: Coffee_Table_13936 -
Copy3
29 Haworth_Chair_Crossoft: Arms 1030 Poltrona_00009_13200 - Copy:
Poltrona_00009_13200 - Copy2
32 iMac_20quot_Intel_Computer_4508:iMac_20quot_Intel_Computer_4508
6
33 Prisma_Desks with credenza support_160cmcredenza unit (1): PM75
5
Grand total: 116
3/16" = 1'-0"1 THIRD FLOOR FURNITURE PLAN
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
POWER PLAN LEGENDElectrical Fixtures : Outlet Floor-Duplex : Single
Electrical Fixtures : Outlet Floor-Single : Single
Electrical Fixtures : Outlet-GFI : Single
Electrical Fixtures : Outlet-Range : Single
Electrical Fixtures : Switch-Dimmer : Dimmer
Electrical Fixtures : Switch-Single : Single
Electrical Fixtures : Switch-Double
Electrical Fixtures : Outlet-Communications : CATV
Electrical Fixtures : Outlet-Communications : TelData
Electrical Fixtures : Outlet-Communications : Telephone
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
3/16" = 1'-0"
12/1
2/20
15 7
:54:
45 P
M
ID-1.03
THIRD FLOORPOWER PLAN
CheckerAuthor
Dec.18 2015Art Institute of Houston
1.
3.
2.CODE.
5.
7.
OTHERS.
6.
8.
9.
10.
11.
4.
THE ELECTRICAL CONTRACTOR SHALL MAKE FINAL CONNECTIONS FOR FLOOR OR WALL OUTLETS
OF FLOOR OUTLETS FEEDING FURNITURE SYSTEM POWER PANELS.ELECTRICAL CONTRACTOR FOR INTERIOR DESIGNER APPROVAL PRIOR TO THE DRILLINGALL CORE LOCATIONS AND FURNITURE PARTITIONS SHALL BE CHALKED ON THE FLOOR BY THE
INDICATE FUNCTION ONLY AND DO NOT NECESSARILY DEFINE THE TYPE, QUANTITY OR EXACTSYMBOLS FOR ELECTRICAL, TELEPHONE, AND DATA FLOOR OUTLETS SHOWN ON "E" PLAN
PROVIDE MULTIGANG JUNCTION BOX AND COVER PLATE AS REQUIRED.ALL SWITCHES SHALL BE GANGED TOGETHER (WHEN THEY APPEAR TIGHTLY TOGETHER)
LOCATION OF DEVICE OUTLETS REQUIRED.
FINAL EXIT SIGN AND EMERGENCY LIGHT LOCATIONS ARE SUBJECT TO THE APPROVAL OF THE
AS REQUIRED TO LOCAL, MUNICIPAL, FIRE PREVENTION CODES ,AND ADA/TAS CODESALL FIRE ALARM PULL AND SIGNAL STATIONS AND LIFE SAFETY SYSTEMS SHALL CONFORM
WITH TEFLON COATED WIRE APPROVED FOR RETURN-AIR PLENUM USE. WIRING TO BE BYALL TELEPHONE AND DATA OUTLETS TO HAVE A PLASTER RING WITH PULL STRING FOR WIRING
ALL SEPARATE CIRCUITS ARE TO BE FURNISHED WITH DISCONNECT SWITCHES AS REQUIRED BY
STAGGERED TO REDUCE NOISE TRANSMISSION THROUGH PARTITION.WHERE TELEPHONE AND ELECTRICAL OUTLETS APPEAR BACK TO BACK, OUTLET BOXES ARE TO BE
ALL WORK TO BE DONE IN ACCORDANCE WITH THE CITY OF ADDRESS LISTED. ELECTRICALCODES AND ALL OTHER STATE AND LOCAL CODES THAT HAVE AUTHORITY OVER THIS PROJECT.
ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR THE CUTTING AND PATCHING REQUIRED FOR
ACCORDANCE WITH TENANTS LAYOUTS.
CITY OF ADDRESS LISTED PER THIS SHEET.
THE INSTALLATION OF THEIR WORK.
ELEC/TELE NOTES
13.
12.
14.
CONTRACTOR TO IDENTIFY ALL SEPARATE AND/OR DEDICATED CIRCUIT OUTLETS AND VERIFYUSE. DEDICATED CIRCUIT RECEPTACLE COLOR TO BE ORANGE.
AT LOCATIONS WITH SIDE BY SIDE ELECTRICAL AND T-STAT, BOTH DEVICES TO BE LEVEL TOEACH OTHER AND PLUMB.
ALL EXIT SIGNS TO MEET LOCAL CITY CODE PER BULDING RATING.
FEEDING ELECTRICITY TO FURNITURE SYSTEMS POWER PANELS.
3/16" = 1'-0"1 POWER PLAN
3/16" = 1'-0"POWER PLAN LEGEND
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
RCP LEGENDLighting Fixtures : Downlight - Recessed Can : 8" Incandescent - 277V
Lighting Fixtures : Downlight - Wall Washer : 8" Incandescent - 277V
Lighting Fixtures : Downlight - Recessed Can : Fluorescent - 277V
Lighting Fixtures : Troffer Light - Lens : 2'x2' Lamp) - 277V
Lighting Fixtures : Troffer Light - Lens : 2'x4'(4 Lamp) - 277V
Lighting Fixtures : Suspended_Light_11176
Lighting Fixtures : EN HALLA UNDA 2 (suspended)
Lighting Fixtures : Light_Pendant_13143 : Type 1
Lighting Fixtures : EN HALLA ARBO Suspended (suspended) (1)
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
3/16" = 1'-0"
12/1
2/20
15 7
:55:
13 P
M
ID-1.04
THIRD FLOOR RCPPLAN
CheckerAuthor
Dec.18 2015Art Institute of Houston
1.
3.
2.
5.
8.
7.
6.
4.
CONTINUOUS OVER TOP OF BUILDING STANDARD PARTITIONS UNLESS NOTED OTHERWISE.CEILING TO BE INSTALLED ACCORDING TO STANDARD BUILDING PRACTICES. ALL GRID IS TO BE
ALL DIMENSIONS OF INCANDESCENT LIGHTING FIXTURES ARE GIVEN TO CENTER TO CENTER LINE,UNLESS OTHERWISE INDICATED. ALL LIGHT FIXTURES TO ALIGN UNLESS OTHERWISE NOTED.WHERE INCANDESCENT LIGHTING IS SHOWN IN GRID, INSTALL IN CENTER OF TILE.
PROVIDE AND INSTALL INSULATION ABOVE CEILING PER LOCAL CODE AUTHORITIES.
DESIGNER EXACT LOCATION OF ACCESS PANELS PRIOR TO INSTALLATION.WHERE THERE IS GYPSUM BOARD OR CONCEALED SPLINE CEILING, VERIFY WITH INTERIOR
ALL CEILING GRILLES TO MATCH EXISTING UNLESS NOTED OTHERWISE.
CONDITIONS, CONTRACTOR IS TO FIELD VERIFY THE FINAL LOCATION OF THE LIGHT FIXTURE AND
PROPERTY MANAGER TO GIVE APPROVAL OF LOCATION PRIOR TO INSTALLATION.CONTRACTOR IS TO IDENTIFY ANY ACCESS PANELS FOR OVER-HEAD CONTROLS, WHERE NEEDED,
NOTIFY INTERIOR DESIGNER OF ANY DISCREPANCIES.
GANG SWITCHES UNDER SINGLE COVER PLATE WHERE MORE THAN ONE IS SHOWN.
WHERE DISCREPANCY OCCURS BETWEEN REFLECTED CEILING GRID AND ACTUAL FIELD
CEILING NOTES
9. THERMOSTAT LOCATIONS TO BE APPROVED BY INTERIOR DESIGNER PRIOR TO INSTALLATION.
3/16" = 1'-0"1 THIRD FLOOR RCP
3/16" = 1'-0"RCP LEGEND
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
Level 10"
ROOF36' - 0"
Level 212' - 0"
Level 324' - 0"
Level 10"
ROOF36' - 0"
Level 212' - 0"
Level 324' - 0"
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
1/8" = 1'-0"
12/1
2/20
15 7
:58:
46 P
M
ID-2.00
EXTERIORELEVATIONA S/E
CheckerAuthor
Dec.18 2015Art Institute of Houston
1/8" = 1'-0"1 SOUTH
1/8" = 1'-0"2 EAST
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
Level 10"
ROOF36' - 0"
Level 212' - 0"
Level 324' - 0"
Level 10"
ROOF36' - 0"
Level 212' - 0"
Level 324' - 0"
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
3/16" = 1'-0"
12/1
2/20
15 7
:59:
15 P
M
ID-3.00
BUILDINGSECTIONS
CheckerAuthor
Dec.18 2015Art Institute of Houston
3/16" = 1'-0"1 LONGITUDINAL BUILDING SECTION
3/16" = 1'-0"2 TRANSVERSE BUILDING SECTION
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
Level 324' - 0"
4' -
0"10
"2'
- 8"
2' -
0"
1' -
1 1/
4"4'
- 10
"1'
- 0"
6' -
11"
0"3'
- 1"6' - 0"
3' - 1" 5' - 1"
MEN PUBLICRESTROOM
48
WOMEN PUBLICRESTROOM
49
5' -
1"3'
- 1"
3' -
1"
1' -
6"
1' -
6"
2' - 0" 2' - 0"
8' - 8"8' - 8"
5' - 0" 5' - 0"
3' -
1"5'
- 1"
19' -
0 1
/2"
BATHROOM105
9' - 8 1/2"
2' - 11"
2' -
11" 1' -
6"
6' -
10"
2' -
0"
KITCHEN120
16' - 0 1/4"
16' -
10
1/4"
2' -
1 1/
4"
2' -
5 1/
2"3'
- 0"
2' - 0"
90.00
°
8' -
8 1/
2"
Level 324' - 0"
Level 324' - 0"
3' -
1"
1' - 11 1/2"1' - 11 1/2"1' - 11 1/2"1' - 11 1/2"2' - 7 1/2" 1' - 11 1/2"
Level 324' - 0"1/
2"2'
- 11
1/2
"7'
- 0
1/2"
1' - 6"
2' -
2 3/
4"4'
- 0"
6 3/
4"
6' - 10"
Level 324' - 0"
7' -
3"2'
- 9"
3' -
5 1/
4"6'
- 6
3/4"
6' - 10"
2' - 11 1/4"
10' -
0"
Level 324' - 0"
3' -
1"
2' - 7 1/2" 2' - 7 1/2" 1' - 5 1/4"2' - 5 1/2"
5' -
7 1/
4"
1' -
11"10
' - 0
"
16' - 10 1/4"
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
3/8" = 1'-0"
12/1
2/20
15 7
:59:
46 P
M
ID-4.00
ENLARGED PLANSAND ELEVATIONS
CheckerAuthor
Dec.18 2015Art Institute of Houston
3/8" = 1'-0"1 MENS RESTROOM
1. ALL MILLWORK IS TO MEET "AWI" QUALITY STANDARDS FOR "CUSTOM" GRADE WORK U.N.O.
MILLWORK NOTES
3.
MYLARS.
4.
5.
6.
7.
9.DRYWALL PARTITION.
CONDITIONS.
8.
REFER TO ELEVATIONS, SECTIONS, AND DETAILS FOR FINISH SPECIFICATIONS.
SHOP DRAWINGS SHALL BE ORIGINAL DRAWINGS PREPARED BY MILLWORK CONTRACTOR WHICHILLUSTRATE MATERIALS, FABRICATION, LAYOUT, SETTING, AND ERECTION DETAILS, PREPARED
COORDINATE WITH ELECTRICAL CONTRACTOR ON EXACT PLACEMENT OF ELECTRICAL FIXTURES,
WHERE WOOD SURFACES ARE PAINTED, WOOD IS TO PROPERLY SEALED, SANDED, PRIMED, AND
FOR APPROVAL PRIOR TO FABRICATION. ONE SET OF BLUELINES AND ONE SET OF SEPIA
MILLWORKER IS TO FIELD VERIFY ALL CONDITIONS WHERE MILLWORK IS TO BE INSTALLED ANDCOORDINATE WITH THE GENERAL CONTRACTOR. SHOP DRAWINGS SHOULD REFLECT FIELD
BY A QUALIFIED DETAILER.
PRIOR TO CONSTRUCTION.
SWITCHES AND OUTLETS TO BE INSTALLED WITHIN MILLWORK.
MILLWORK WITH SPLASHES TO HAVE THE SPLASH CONTINUE AT ALL LOCATIONS THAT ABUTT A
TO RECEIVE 2 COATS, MINIMUM, SPECIFIED PAINT. SUBMIT SAMPLES TO INTERIOR DESIGNERPRIOR TO CONSTRUCTION.
SUBMIT SAMPLES OF SPECIFIED FINISHES TO INTERIOR DESIGNER FOR APPROVAL
SHOP DRAWINGS FOR MILLWORK CONSTRUCTION TO BE SUBMITTED TO STATTON ASSOCIATES, INC.2.
3/8" = 1'-0"2 PUBLIC RESTROOMS
3/8" = 1'-0"3 APARTMENT BATHROOM
3/8" = 1'-0"4 KITCHEN
3/8" = 1'-0"5 WOMENS BATHROOM
3/8" = 1'-0"6 KITCHEN SOUTH
3/8" = 1'-0"7 APARTMENT BATHROOM EAST
3/8" = 1'-0"8 APARTMENT BATH WEST
3/8" = 1'-0"9 KITCHEN EAST
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
12/1
2/20
15 7
:59:
49 P
M
ID-5.00
DETAILS
CheckerAuthor
Dec.18 2015Art Institute of Houston
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
RCP LEGENDLighting Fixtures : Downlight - Recessed Can : 8" Incandescent - 277V
Lighting Fixtures : Downlight - Wall Washer : 8" Incandescent - 277V
Lighting Fixtures : Downlight - Recessed Can : Fluorescent - 277V
Lighting Fixtures : Troffer Light - Lens : 2'x2' Lamp) - 277V
Lighting Fixtures : Troffer Light - Lens : 2'x4'(4 Lamp) - 277V
Lighting Fixtures : Suspended_Light_11176
Lighting Fixtures : EN HALLA UNDA 2 (suspended)
Lighting Fixtures : Light_Pendant_13143 : Type 1
Lighting Fixtures : EN HALLA ARBO Suspended (suspended) (1)
POWER PLAN LEGENDElectrical Fixtures : Outlet Floor-Duplex : Single
Electrical Fixtures : Outlet Floor-Single : Single
Electrical Fixtures : Outlet-GFI : Single
Electrical Fixtures : Outlet-Range : Single
Electrical Fixtures : Switch-Dimmer : Dimmer
Electrical Fixtures : Switch-Single : Single
Electrical Fixtures : Switch-Double
Electrical Fixtures : Outlet-Communications : CATV
Electrical Fixtures : Outlet-Communications : TelData
Electrical Fixtures : Outlet-Communications : Telephone
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
3/16" = 1'-0"
12/1
2/20
15 7
:59:
59 P
M
ID-6.00
SCHEDULES ANDDIAGRAMS
CheckerAuthor
Dec.18 2015Art Institute of Houston
ROOM SCHEDULE
Name
48 MENPUBLICRESTROOM
49 WOMENPUBLICRESTROOM
127 COPYROOM
103 LOBBY105 BATHROO
M108 CLOSET111 CONFERE
NCEROOM
110 KITCHEN112 DOCTOR'S
OFFICE A113 APARTME
NT114 EXAM
ROOM D115 EXAM
ROOM C116 DOCTOR'S
OFFICE B117 EXAM
ROOM B118 EXAM
ROOM A119 RECEPTIO
N A120 KITCHEN121 LOUNGE122 OFFICE C123 OFFICE B124 OFFICE A125 OFFICE
STATIONS126 STORAGE130 RECEPTIO
N B131 LOUNGE A
FURNITURE SCHEDULE
Type Mark Family and Type Count
121 Haworth_Chair_Very-Perforated Conference: Arms 182 Dining_Table_w_2Chair - Copy: 762 mm x 1525 mm 13 Modern_Office_Desk_8428:
Modern_Office_Desk_84288
6 Sofa-Corbu: Sofa 57 Chair-Task Arms: Chair-Task Arms 39 Armchair_-_Crescent: Armchair_-_Crescent 610 Steelcase Coalesse - Circa - Seating - Round
Ottoman: Ottoman1
11 Ricoh_copier_14254 (1): Ricoh_copier_14254 (1) 213 Table-Coffee: 24" x 24" x 24" 214 Corporate_Desk_-_Designer_Series_11327:
Corporate_Desk_-_Designer_Series_113271
15 Credenza_1066: Credenza_1066 416 Chair-Corbu: Chair 417 HighTower_Arroyo_Bench: HighTower_Arroyo_Bench 118 blaise_sofa_6129: blaise_sofa_6129 119 Coffee_table_10605: Coffee_table_10605 120 6_Drawer_Dresser_12521: 6_Drawer_Dresser_12521 121 Medical_scale_bascula_medica_11736:
Medical_scale_bascula_medica_117364
23 File_Cabinet_1024: File_Cabinet_1024 624 Archipelago_Table_Ø85_H35:
Archipelago_Table_Ø85_H351
25 Gus_Modern_Return_Bench_10855:Gus_Modern_Return_Bench_10855
4
26 Tinto_Center_Easy_Chair: Tinto_Center_Easy_Chair_ 427 Coffee_Table_13936 - Copy: Coffee_Table_13936 -
Copy3
29 Haworth_Chair_Crossoft: Arms 1030 Poltrona_00009_13200 - Copy:
Poltrona_00009_13200 - Copy2
32 iMac_20quot_Intel_Computer_4508:iMac_20quot_Intel_Computer_4508
6
33 Prisma_Desks with credenza support_160cmcredenza unit (1): PM75
5
Grand total: 116
DOOR SCHEDULE
Type Mark CountFamily and
Type Width Height Description
A 19 3' - 0" 7' - 0"B 3 Single-Glas
s 1: 36" x84"
3' - 0" 7' - 0" SINGLE-GLASS
C 3 Double-Glass 1: 72" x84"
6' - 0" 7' - 0" DOUBLE-GLASS
G 1 Double-Flush: 72" x 84"
6' - 0" 7' - 0"
VVVV 1 Single-Panel 4: 36" x84"
3' - 0" 7' - 0"
Grand total: 27
3/16" = 1'-0"RCP LEGEND
3/16" = 1'-0"POWER PLAN LEGEND
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
12/1
2/20
15 8
:00:
04 P
M
ID-9.00
3DVISUALIZATIONS
CheckerAuthor
Dec.18 2015Art Institute of Houston
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
RECEPTION 1 APARTMENT
DOCTOR'S OFFICE EXAM ROOM
LOUNGE CONFERENCE ROOM
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
12/1
2/20
15 8
:00:
07 P
M
ID-9.01
3DVISUALIZATIONS
CheckerAuthor
Dec.18 2015Art Institute of Houston
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date
LOBBY RECEPTION 2
OFFICE OFFICE WORK STATIONS
KITCHEN BREAK LOUNGE
MEN PUBLICRESTROOM
48
WOMEN PUBLICRESTROOM
49
COPY ROOM127
Room Legend
APARTMENT
BATHROOM
CLOSET
COPY ROOM
DOCTOR'S OFFICE A
DOCTOR'S OFFICE B
EXAM ROOM A
EXAM ROOM B
EXAM ROOM C
EXAM ROOM D
KITCHEN
LOBBY
LOUNGE
LOUNGE A
MEN PUBLIC RESTROOM
OFFICE A
OFFICE B
OFFICE C
OFFICE STATIONS
RECEPTION A
RECEPTION B
STORAGE
WOMEN PUBLIC RESTROOM
LOBBY103
BATHROOM105
EXAM ROOM C115
DOCTOR'SOFFICE B
116
EXAM ROOM B117
EXAM ROOM A118 EXAM ROOM D
114
RECEPTION A119
CONFERENCEROOM
111
KITCHEN110
DOCTOR'SOFFICE A
112
APARTMENT113
STORAGE126
CLOSET108
OFFICE A124
OFFICE B123
OFFICE C122
1135 SF
OFFICE STATIONS125
KITCHEN120
LOUNGE121
RECEPTION B130
LOUNGE A131
Scale
Date
QUARTER
INSTRUCTOR
INSTITUTION
3/16" = 1'-0"
12/1
2/20
15 8
:01:
06 P
M
NFC-1
ROOM LEGEND
CheckerAuthor
Dec.18 2015Art Institute of Houston
3/16" = 1'-0"1 ROOM LEGEND
LOUIS ARRIOLAADVANCED
CONSTRUCTIONDOCUMENTS
ID 312 FALL 2016
No. Description Date