bel catalog 2008

76
2008 CATALOG Viscometers, Rheometers & Texture Analyzers for Laboratory and Process Applications

Upload: yogiindraprayoga

Post on 21-Jul-2016

49 views

Category:

Documents


9 download

DESCRIPTION

brookfield

TRANSCRIPT

Page 1: BEL Catalog 2008

2008 CATALOG Viscometers, Rheometers & Texture Analyzersfor Laboratory and Process Applications

Page 2: BEL Catalog 2008

� T: 800.6�8.8139 or 508.946.6�00 F: 508.946.6�6� www.brookfieldengineering.com

To our customers,

This past year, we have focused on the importance of quality improvements, both in our internal procedures and in our products. For instance, we introduced a new look and added more options, including enhanced electronics and data output, with the launch of our new DV-I Prime Viscometer. In addition, our popular AST-100 In-line Viscometers are now available in a flange mount design for convenient mounting and also in a probe style for insertion into tanks from above. We also introduced two new time-saving options for our digital viscometer line: our Quick Action Lab Stand moves viscometers up and down the lab stand with a push of a button while the EZ-Lock Spindle Coupling System allows operators the convenience of quickly attaching spindles without the need of threading.

We continue to look forward to providing you with improved measurement systems. Coming in 2008, a new Texture Analyzer with tension and compression capabilities normally found in much higher priced instruments will be introduced. Also coming soon, one of our most popular instruments will get a new look, and we are also excited about the debut of a new robust viscometer that can stand on its own in just about any industrial environment. Be sure to check our website for the introduction of these exciting new instruments in 2008.

David Brookfield,President

IndexWhy Measure Viscosity ..................................4Laboratory DV-II+Pro Viscometer ............................6 DV-I Prime Viscometer ..........................8 DV-E Viscometer ................................... 10 Dial Reading Viscometer ................... 11 Wells/Brookfield Cone & Plate ......... 1� CAP �000+ and CAP 1000+ .............. 14 DV-III Ultra Rheometer ....................... 16 PVS Rheometer ..................................... 18 R/S Plus Rheometers ........................... �0 R/S-SST Rheometer ............................. �3 YR-1 Rheometer ................................... �4 KU-� Viscometer ................................... �6Temperature Control Water Baths ............................................ �7 Thermosel ............................................... 30Accessories: Small Sample Adapter ....................... 3� Enhanced UL Adapter ........................ 34 Helipath Stand ...................................... 36 Vane Spindles ........................................ 37 Adapters (DIN, Spiral) ......................... 38 Spindles, Cups, Chambers ................ 39 Quick Connect ...................................... 43 Protective Cover ................................... 43 Torque Decals ........................................ 43 Viscosity Standards ............................. 44Texture Analyzers What is Texture Analysis? .................. 46 LFRA Texture Analyzer ....................... 48 QTS-�5 Texture Analyzer ................... 50Brookfield Systems Starch ....................................................... 5� Chocolate ............................................... 5� Paints/Coatings/Ink ............................. 53 Asphalt..................................................... 53 Personal Care Products ...................... 54 Electronics Paste .................................. 55 Pharmaceutical ..................................... 55 Petroleum ............................................... 56 Dairy Products ...................................... 57 Adhesives ............................................... 57 Sauces & Dressings .............................. 58 Construction Materials ...................... 58Process Why Process? ......................................... 59 AST-100 Viscometer Series ............... 60 TT-100 Viscometer Series .................. 6� TT-�00 Viscometer Series .................. 64 Probe Viscometer Series .................... 65 Viscosel Series (VTE & VTA) ............... 66 Accessories ............................................. 68General Testing & Consulting Services ......... 69 Ball Bearing Suspension .................... 70 Calibration and Certification ........... 70 IQ, OQ, PQ ............................................... 70 Education ................................................ 71 Glossary ................................................... 7� Dealers ..................................................... 73

Page 3: BEL Catalog 2008

3

This year’s highlights.

EZ-Lock Spindle Coupling SystemSafely attach spindles in much less time with this innovative, spring-loaded spindle coupling design. Attach the new coupling to your spindle and simply insert the spindle into the chuck. That’s it! EZ-Lock can be purchased as an option with new instruments or retrofitted to many existing instruments. Available on the following models: DV-I+/Prime Viscometers, DV-II+ series Viscometers, and DV-III+/Ultra Rheometers.

NEW Protective Keypad CoversProtect keypads against dirt, scratches, spillage and dust with our new “peel and stick” flexible covers. Packaged in quantities of 10, they are ideal for instruments with multiple users and busy, high traffic work areas. Use with DV-I series, DV-II series, CAP series, DV-III series, YR-1, VTE series and AST-300SY touch screen controller models.

DV-I Prime Viscometer Note the attractive look and feel along with several exciting new features including “Timed Option” and “Print” buttons. Optional WINGATHER software allows use of a PC to collect, analyze and record viscosity test data. Continuous torque sensing and data display easily make the DV-I Prime Viscometer one of the best values in the market!

AST-100 Process Viscosity Controller DesignsThe popular AST-100 in-line viscosity control system now has new mounting design options.Both instrument options maintain the features of our standard AST-100 design, with no moving parts and no need for recalibration.

Flange MountFlange mount designs are available to allow direct mounting onto a process tank through a sidewall flange.

Probe StyleThis design allows for insertion into the tank from above.

Quick Action Lab StandSimply push a button. Your viscometer moves in an easy, continuous motion up/down the lab stand, allowing for quick positioning and faster testing. Perfect for environments with heavy workloads, multiple users and varied testing situations. Available as an option for use with both new and existing Brookfield Viscometers/Rheometers.

Page 4: BEL Catalog 2008

4 T: 800.6�8.8139 or 508.946.6�00 F: 508.946.6�6� www.brookfieldengineering.com

DV-IIIUltra

Cone/Plate

SpecialPurposeInstruments

Price

Performance

R/SSoft

SolidsTester

• Torque

• Calculates Viscosity• Torque

• Optional Temp Probe• Calculates Viscosity• Torque

• Temp Probe• RS232 (PC control)• Calculates Viscosity• Torque

• Stand Alone Programmable• Temp Probe• RS232 (PC control)• Data Analysis• Calculates Viscosity• Torque• Yield Stress

DialReading

DV-E

DV-II+Pro

R/SCoaxial

Cylinder

• Controlled Stress & Rate• Yield Stress• Stand Alone Programmable• Temp Probe• RS232 (PC control)• Calculates Viscosity• Torque

YR-IYield

TestRheometer

CAP I000+Cone/Plate

• Yield Stress • KREBS Viscosity• Required for Paint and Coatings

• Single Shear Rate• Required for Paint and Coatings

• Yield Stress• Creep• Recovery

PVSRheometer

• Pressurized Sample Chamber• Controlled Rate• Temp Probe• RS232 (PC control)• Calculates Viscosity• TorqueCAP

2000+Cone/Plate

• Small Sample Size• Defined Shear Rate

• Small Sample Size• Defined Shear Rate

• Small Sample Size• Defined Shear Rate

• Broad Shear Rate Range• Peltier Plate Temp Control• RS 232 (PC control)

• Peltier Plate

DV-IPrimeCone /

Plate

Choices for InstrumentationThis chart shows the Brookfield family of Laboratory Viscometers and Rheometers at a glance. This will help to give you a general idea of what is available before making a decision. The horizontal axis indicates performance capability and features while the vertical axisaddresses price level.

Need to measure viscosity in-line? Brookfield also offers a complete line of process viscometers. (p59)

DV-II+Pro

Cone/Plate

R/SCone/Plate

DV-IIIUltra

KU-2KREBS

Brookfield also offers several special purpose instruments which are used to perform a specific type of test or are used to evaluate certain types of materials.

DV-IPrime

BROOKFIELD VISCOMETERS & RHEOMETERS

Why measure viscosity?The ability to gather data on a material’s viscosity behavior gives manufacturers an important “product dimension.” Knowledge of a material’s rheological characteristics is valuable in predicting its pourability, its performance in a dipping or coating operation, or the ease with which it may be handled, processed, or used. The interrelation between rheology and other product dimensions often makes the measurement of viscosity the most sensitive or convenient way of detecting changes in color, density, stability, solids content, and molecular weight.

Why Choose Brookfield?Ease of use, flexibility, reliable performance and quality of service have made Brookfield Viscometers favorites all over the world. All Brookfield Viscometers are accurate within ±1.0% of the range in use and have a reproducibility within ±0.�%. Test results can be duplicated anywhere in the world when the same model instrument is used.

Page 5: BEL Catalog 2008

5

** Standard torque range values * Minimum ranges can be extended to as lowas 1 cP with the use of Brook�eld Accessories

M = 1 million

LVTLVDV-ELVDV-I+LVDV-II+PLVDV-IIIURVTRVDV-ERVDV-I+RVDV-II+PRVDV-IIIUHATHADV-EHADV-I+HADV-II+PHADV-IIIUHBTHBDV-EHBDV-I+HBDV-II+PHBDV-IIIU

1*1*1*1*1*

100100100100100200200200200200800800800800800

2 M2 M2 M6 M6 M8 M

13 M13 M40 M40 M16 M26 M26 M80 M80 M64 M

104 M104 M320 M320 M

44444666666666666666

81818

54 selectable0.01 to 250

101818

54 selectable0.01 to 250

101818

54 selectable0.01 to 250

101818

54 selectable0.01 to 250

**MODEL

Hig

h Vi

scos

ityM

ediu

m V

isco

sity

Low

Vis

cosi

ty

SPEE

DS

# of S

pind

les

Sup

plie

d

Min. cP

(mPa

•s)

VISC

OSITY R

ANGE

Max. cP

(mPa

•s)

VISC

OSITY R

ANGE

Model Selection TableBrook�eld StandardViscometers/Rheometers

Questions to Consider1. What is the viscosity range of your material: Low, medium, high?

�. What rotational speeds or shear rates are important?

3. How much sample is available for testing?

4. Is temperature measurement/control necessary?

5. Do you need to record the viscosity data?

The Selection MethodThe Model Selection Table (shown at right) shows detailed information on standard Brookfield Viscometers/Rheometers, including the Dial Reading, DV-E, DV-I Prime, DV-II+Pro, and DV-III Ultra. The Applications Table (shown at lower right) shows information on typical applications of the standard Brookfield viscosity ranges. There may be industry or supplier/vendor specifications that you need to duplicate. Before making a final selection, we suggest that you confer with people in your industry to find out which Brookfield Viscometer they are using so that your data can be correlated. More application details may be found throughout this catalog for other Brookfield instruments on the following pages:

CAP1000+/�000+ Viscometers (p14-15) YR-1 Rheometer (p�4-�5)

PVS Rheometer (p18-19) KU-� Viscometer (p�6)

R/S Plus series Rheometers (p�0-�3) Texture Analyzers (p46-51)

In addition, you may wish to call us and discuss your application or refer to our extensive library of technical papers which covers a complete spectrum of applications. We can also test your materials at Brookfield to recommend the instrument most suitable for your application.

SpindlesStandard Brookfield Viscometers/Rheometers are supplied with a standard spindle set constructed of stainless steel (#30�). Additional spindle options are available in #316 stainless steel or with Teflon coating for increased corrosion resistance. Other spindles and accessories are also available. (p39-43)

Cylindrical SpindlesCylindrical spindles are particularly valuable when measuring non-Newtonian fluids and are applicable to any Brookfield Viscometer model with the use of appropriate range tables. Cylindrical spindles may be substituted for standard spindles upon request.

LV Spindle Set RV/HA/HB Spindle SetOptional

Cylindrical Spindle Set

Need additional assistance? Our website, www.brookfieldengineering.com, contains additional information on the measurement selection process as well as detailed application notes.

Applications TableConsider application and viscosity range when selecting model (LV, RV, HA, HB)

LV SERIES – LOW VISCOSITY Adhesives (solvent base) Inks Photo ResistBiological Fluids Juices Polymer SolutionsChemicals Latex Rubber SolutionsCosmetics Oils SolventsDairy Products Paints and Coatings Hot Waxes Pharmaceuticals

RV SERIES – MEDIUM VISCOSITY Adhesives (hot melt) Gums PlastisolsAsphalt (SHRP) Inks (screen printing) StarchesCeramic Slurries Organisols Surface CoatingsCreams Paints ToothpasteDairy Products Paper Coatings Varnish Food Products Paper Pulp

HA/HB SERIES – HIGH VISCOSITY Asphalt Pastes Caulking Compounds Peanut Butter Chocolate Putty Epoxies Roofing Compounds Gels Sealants Inks (ballpoint, offset, lithographic) Sheet Molding Compound Molasses Tars

Page 6: BEL Catalog 2008

� T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

LVDV-II+PRVDV-II+PHADV-II+PHBDV-II+P

MODEL Min.

VISCOSITYRANGE

cP(mPa•s)

Max. RPMNumber ofIncrements

6M40M80M

320M

SPEEDS

1†100††200††800††

54545454

.01-200

.01-200

.01-200

.01-200† 1 cP achieved with UL Adapter accessory. 15 cP on LV with standard spindles. †† Minimum viscosity is achieved with optional RV/HA/HB-1 spindle.M = 1 million cP = Centipoise mPa•s = Millipascal/seconds

Displayed Info:–Viscosity (cP or mPa•s)–Temperature (°C or °F)–Shear Rate/Stress–% Torque–Speed/Spindle

Accuracy: ±1.0% of range

Repeatability: ±0.2%

Customizable Options

Scroll Keys for Simple Selection of Speed & Spindle

Built-in RTD Temperature Probe

Bi-directional RS-232 PC interface provides optional computer control and

automatic data gathering capability

Auto Range Showing–Full Scale Range (FSR) at 100%–Maximum viscosity measured

with Spindle/Speed combination

54 selectable speeds provide superior range of

viscosity/shear rate measurements

Download custom test programs with DV Loader software

(included with instrument)

Complete computer control with optional Rheocalc software

DV-II+Pro Viscometer our most versatile continuous sensing viscometer

BROOKFIELD VISCOMETERS

Page 7: BEL Catalog 2008

DV-II+Pro CP The DV-II+Pro is available in a Wells/Brookfield Cone & Plate Version (p12)Must be ordered when instrument is first purchased.

What’s Included?Instrument

� spindles (RV/HA/HB) (p39)

or 4 spindles (LV) (p39)

DV Loader software E

RTD Temperature Probe

Spindle Guard Leg*

Lab Stand (Model S)

Carrying Case *Not applicable to HA or HB versions

Optional AccessoriesRheocalc32 Software E

Wingather Software E

Ball Bearing Suspension (RV/HA/HB) (p�0)

Viscosity Standards (p44)

RV/HA/HB-1 Spindle (p39)

EZ-Lock Spindle Coupling System (p3)

Quick Action Lab Stand (p3)

Temperature Bath (p2�)

Small Sample Adapter (p32)

UL Adapter (p34)

Thermosel (p30)

Helipath Stand with T-bar Spindles (p3�)

Spiral Adapter (p38)

DIN Adapter (p38)

Quick Connect/Extension Links (p43)

Vane Spindles (p3� & 42)

Protective Keypad Covers (p3)

DV Loader Software IncludedCreate custom tests using your PCDV Loader allows users to create repeatable custom tests with choices of parameters for speed, test duration, etc. to be downloaded from a PC to a DV-II+ Pro Viscometer. Disconnect the DV-II+Pro from the PC for secure, user-defined test methods.

Connect DV-II+Pro to a PC to create a custom test program on your PC and then download test parameters to your viscometer

Rheocalc32 Software OptionalGet total control of your instrument and test parametersAutomatically control and collect data with Rheocalc32 and a dedicated computer. Rheocalc32 can analyze data, generate multiple plot overlays, print tabular data, run math models and perform other time-saving routines. Data can be saved in the program or exported to Excel. –Controls test parameters with powerful scripting capabilities–NEW wizard for self-guiding creation of test programs–Looping functions for repetitive tasks–Automates data collection to save time–Math modeling for yield stress calculations, plastic index–Plot up to five data sets for comparisons

Wingather Software Optional Data collection software to collect, analyze and record test dataWingather software provides an easy way to gather data and plot graphs while creating permanent test records. Data can be saved in the program or exported to Excel. –Automates data collection to save time–Reduces operator error–Math modeling for yield stress calculations, plastic index–Plot up to five data sets for comparisons

Page 8: BEL Catalog 2008

8 T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

Accuracy: ±1.0% of range Repeatability: ±0.2%

Optional RTD Temperature Probe DVP-94Y Must be ordered when instrument is first purchased.

Displayed info:–Viscosity (cP or mPa•s)–% Torque–Speed/Spindle–Temperature (°C or °F) if optional RTD Temperature Probe is installed

New Sleek look with simple-to-use keypad

Analog outputs for recording torque and temperature(optional)

18 speeds provide great range capability

Displays under/over range conditions

Scroll Keys for Simple Selection

of Speed & Spindle

Auto Range Showing–Full Scale Range (FSR) at 100%–Maximum viscosity measured

with Spindle/Speed combination

New RS-232 PC interface for use with optional Wingather Software

New Direct access to time measurement function (time to torque, time to stop)

New Temperature off-set capability to ±1°C

New Output connection to printer

LVDV-IPRVDV-IPHADV-IPHBDV-IP

MODEL** Min.

VISCOSITYRANGE

Max. RPMNumber ofIncrements

2M13M26M

104M

SPEEDS

1*100200800

18181818

.3-100

.3-100

.3-100

.3-100* Minimum ranges can be extended to as low as 1 cP with the use of Brook�eld Accessories

** Standard torque range values

BROOKFIELD VISCOMETERS

NEW DV-I Prime Viscometer The only viscometer in its class to offer continuous sensing and data display!

Page 9: BEL Catalog 2008

9

What’s Included?Instrument � spindles (RV/HA/HB) (p39) or 4 spindles (LV) (p39) Spindle Guard Leg* Lab Stand (Model S) Carrying Case *Not applicable to HA or HB versions

Optional AccessoriesRTD Temperature Probe

Ball Bearing Suspension (RV/HA/HB) (p�0)

Viscosity Standards (p44)

RV/HA/HB-1 Spindle (p39)

Quick Action Lab Stand (p3)

EZ-Lock Spindle Coupling System (p3)

Temperature Bath (p2�)

Small Sample Adapter (p32)

UL Adapter (p34)

Thermosel (p30)

Helipath Stand with T-bar Spindles (p3�)

Spiral Adapter (p38)

DIN Adapter (p38)

Quick Connect/Extension Links (p43)

Vane Spindles (p3� & 42)

Protective Keypad Covers (p3)

DV-I Prime CP The DV-I Prime is available in a Wells/Brookfield Cone & Plate Version (p12)Must be ordered when instrument is first purchased.

Wingather Software Optional Data collection software to collect, analyze and record test dataWingather software provides an easy way to gather data and plot graphs while creating permanent test records. Data can be saved in the program or exported to Excel. –Automates data collection to save time–Reduces operator error–Math modeling for yield stress calculations, plastic index–Plot up to five data sets for comparisons

Page 10: BEL Catalog 2008

10 T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

LVDV-ERVDV-EHADV-EHBDV-E

MODEL Min.

VISCOSITYRANGE

cP(mPa•s)

Max. RPMNumber ofIncrements

2M13M26M

104M

SPEEDS

1†

100††

200††

800††

18181818

.3-100

.3-100

.3-100

.3-100† 1 cP achieved with UL Adapter accessory. 15 cP on LV with standard spindles. †† Minimum viscosity is achieved with optional RV/HA/HB-1 spindle.M = 1 million cP = Centipoise mPa•s = Millipascal/seconds

Displayed info:–Viscosity (cP or mPa•s)–% Torque–Speed/Spindle

Accuracy: ±1.0% of range

Repeatability: ±0.2%

Spindle/SpeedSelection

Flip to “Speed”–Turn the knob

–Choose RPMFlip to “Spindle”–Turn the knob

–Choose spindle

Auto Rangepush for

determining full scale

range (FSR) viscosity

Easy-to-Use: –Flip a switch –Turn a knob 18 Speeds

for complete range capability

No calculations required –Direct reading of viscosity in cP or mPa•s

DV-E Viscometerour lowest cost digital viscometer

BROOKFIELD VISCOMETERS

What’s Included?Instrument

� spindles (RV/HA/HB) (p39)

or 4 spindles (LV) (p39)

Spindle Guard Leg*

Lab Stand (Model A)

Carrying Case *Not applicable to HA or HB versions

Optional AccessoriesViscosity Standards (p44)

RV/HA/HB-1 Spindle (p39)

Quick Action Lab Stand (p3)

Temperature Bath (p2�)

Small Sample Adapter (p32)

UL Adapter (p34)

Thermosel (p30)

Spiral Adapter (p38)

DIN Adapter (p38)

Quick Connect/Extension Links (p43)

Vane Spindles (p3� & 42)

Page 11: BEL Catalog 2008

11

LVTRVTHATHBT

MODEL Min.

VISCOSITYRANGE

cP(mPa•s)

Max. RPMNumber ofIncrements

2M8M

16M64M

SPEEDS

1†

100††

200††

800††

8101010

.3-60

.5-100

.5-100

.5-100† 1 cP achieved with UL Adapter accessory. 15 cP on LV with standard spindles. †† Minimum viscosity is achieved with optional RV/HA/HB-1 spindle.M = 1 million cP = Centipoise mPa•s = Millipascal/seconds

Electronic Drive means quiet, reliable operation

Easy–to–SelectSpeeds

Available in explosion proof U.L. Class 1, Group D locations

(w/o Electronic Drive)

Analog display –Shows % Torque

–Use Factor Finder to convert reading

to centipoise

The Worldwide Standard Viscometer

Accuracy: ±1.0% of range

Repeatability: ±0.2%

Simple-to-use, easy setup

2–Year Limited Warranty

Easy Speed Adjustmentand On/Off Control

What’s Included?Instrument

� spindles (RV/HA/HB) (p39)

or 4 spindles (LV) (p39)

Spindle Guard Leg*

Lab Stand (Model A)

Carrying Case *Not applicable to HA or HB versions

Optional AccessoriesViscosity Standards (p44)

RV/HA/HB-1 Spindle (p39)

Quick Action Lab Stand (p3)

Temperature Bath (p2�)

Small Sample Adapter (p32)

UL Adapter (p34)

Thermosel (p30)

Helipath Stand with T-bar Spindles (p3�)

Spiral Adapter (p38)

DIN Adapter (p38)

Quick Connect/Extension Links (p43)

Vane Spindles (p3� & 42)

Dial Reading Viscometer our original now with electronic drive

Page 12: BEL Catalog 2008

12 T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

RPMNumber ofIncrements

SPEEDS

2.6K5418

2.6K5418

2.6K5418

2.6K5418

.01 - 250

.01 - 2000.3 - 100.01 - 250.01 - 2000.3 - 100.01 - 250.01 - 2000.3 - 100.01 - 250.01 - 2000.3 - 100

LVDV-IIIUCPLVDV-II+PCPLVDV-IPCPRVDV-IIIUCPRVDV-II+PCPRVDV-IPCPHADV-IIIUCPHADV-II+PCPHADV-IPCPHBDV-IIIUCPHBDV-II+PCPHBDV-IPCP

MODEL.1 - 3K.2 - 3K.3 - 1K1 - 32K

1.6 - 32K3 - 10K

2.6 - 65K3 - 65K

6.6 - 21K10.5 - 261K13 - 261K26 - 87K

.5 - 11K

.6 - 11K1 - 3K

5 - 122K6 - 122K12 - 41K

10 - 245K12 - 245K24 - 81K

39 - 982K49 - 982K98 - 327K

.2 - 6K

.3 - 6K

.6 - 2K2 - 64K3 - 64K6 - 21K

5 - 128K6 - 128K12 - 42K

20 - 512K25.6 - 512K51 - 170K

2 - 48K2 - 48K5 - 16K

20 - 512K25 - 512K51 - 170K41 - 1M51 - 1M

102 - 341K163 - 4M204 - 4M409 - 1M

3 - 92K4 - 92K9 - 30K

39 - 983K49 - 983K98 - 327K78 - 2M98 - 2M

196 - 655K314 - 7.8M393 - 7.8M786 - 2.6M

N = RPM e.g. Spindle CPE-40 7.50 x 10 (rpm) = 75.0 sec-1* Dependant upon cone selected.

Cone

Spin

dle C

PE-4

0

Sam

ple V

olum

e .5m

L

Shea

r Rat

e (se

c-1

7.5N

Cone

Spin

dle C

PE-4

1

Sam

ple V

olum

e 2.0

mL

Shea

r Rat

e (se

c-1

2.0N

Cone

Spin

dle C

PE-4

2

Sam

ple V

olum

e 1.0

mL

Shea

r Rat

e (se

c-1

3.84

N

Cone

Spin

dle C

PE-5

2

Sam

ple V

olum

e .5m

L

Shea

r Rat

e (se

c-1

2.0N

Cone

Spin

dle C

PE-5

1

Sam

ple V

olum

e .5m

L

Shea

r Rat

e (se

c-1

3.84

N

Accuracy: ±1.0% of range

Repeatability: ±0.2%

RTD Temperature Sensor in Sample Cup (Optional)provides direct measurement of sample temperature

Electronic Gap Adjustment™–simplified setup

–accurate–easy-to-use

Control Sample Temperature using a Brookfield circulating water bath (p2�)

Determine absolute viscosity of small samples (0.5 – 2.0 mL)

Precise shear rates for determining a material’s

flow curve behaviorAvailable in these models –DV-III Ultra Rheometer –DV-II+Pro Viscometer –DV-I Prime Viscometer

Rapid temperature control due to small sample size

BROOKFIELD VISCOMETERS

Wells/Brookfield Cone & Plate for small samples

Page 13: BEL Catalog 2008

13

ElectronicGap LED’s

VernierAdjustment Ring

Cone Spindle

CupOptional Embedded Temperature Probe (not shown) for direct temperature measurement of sample

Luer Fittingfor sample inlet

Purge Fittingschoice of 2, 3, or 4

What’s Included?Instrument

Lab Stand

Choice of one Cone Spindle (p40)

Sample Cup (p40)

Optional AccessoriesEmbedded Temperature Probe in Sample Cup (p40)

Luer and Purge fittings

NEW Ball Bearing Suspension (p3)

Additional Cone Spindles (p40)

Viscosity Standards (p44)

Circulating Temperature Bath (p2�)

Rheocalc32 Software E (DV-III+ Ultra & DV-II+Pro only)

Wingather Software E (DV-II+Pro only)

Optional Sample Cup with luer and purge fittings for introducing and removing test sample while cup remains attached to instrument

Rheocalc32 Software OptionalGet total control of your instrument and test parametersAutomatically control and collect data with Rheocalc32 and a dedicated computer. Rheocalc32 can analyze data, generate multiple plot overlays, print tabular data, run math models and perform other time-saving routines. Data can be saved in the program or exported to Excel. –Controls test parameters with powerful scripting capabilities–NEW wizard for self-guiding creation of test programs–Looping functions for repetitive tasks–Automates data collection to save time–Math modeling for yield stress calculations, plastic index–Plot up to five data sets for comparisons

Wingather Software Optional Data collection software to collect, analyze and record test dataWingather software provides an easy way to gather data and plot graphs while creating permanent test records. Data can be saved in the program or exported to Excel. –Automates data collection to save time–Reduces operator error–Math modeling for yield stress calculations, plastic index–Plot up to five data sets for comparisons

Page 14: BEL Catalog 2008

14 T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

CAP 1000+CAP 2000+

MODEL Min.

VISCOSITYRANGE*

cP(mPa•s)

Max. RPMNumber ofIncrements

SPEEDS

2995

900/7505-1K

* Dependant on cone selected.M = 1 million K = 1 thousand cP = Centipoise mPa•s = Millipascal/seconds

see chart on

(p15)

Keypad for direct input of test parameters

Easy–to–Use Control Handle for accurate, automatic cone positioning

4–Line Display allows simultaneous viewing

of all test parameters

Choice of instruments:CAP1000+ (single speed)

CAP2000+ (variable speed)

Automatic cone/gap positioning

Cone Spindleis easily removed for cleaning

Built-in Peltier Platefor temperature

control of sample: L Series: 5°C — �5°C

H Series: 50°C — 235°C

Small sample size (less than 1 mL)

Designed to handle repetitive testing in production environments

with easy setup and cleaning

BROOKFIELD VISCOMETERS

CAP 1000+ & CAP 2000+ Cone & Plate Viscometers

Page 15: BEL Catalog 2008

15

Perfect forPaints & Coatings Meets Industry Standards:ASTM D428�, ISO 2884, BS 3900High Shear Rate Cone & Plate (10,000 sec-1)

What’s Included?Instrument

Choice of Torque Range:

High Torque (ICI Specification): 181,000 dyne • cm

Low Torque: �,9�0 dyne • cm

Choice of One Cone Spindle (p40)

Choice of Temperature Control: L or H

Optional AccessoriesCAP Viscosity Standards (p45)

Additional Cone Spindle (p40)

Capcalc32 Software E

Protective Keypad Covers (p3)

CAP1000+: Single speed �50 or 900 rpm instrument, ideal for QC. Optional choice of alternative speed is available upon request. See examples below at 400 rpm and 100 rpm.

CAP2000+: Variable speed 5-1000 rpm instrument ideal for R&D as well as more detailed QC testing. Automated PC control (using optional Capcalc32 software).

Capcalc32 Software OptionalTurn your CAP2000+ Viscometer into a more powerful rheometerCapcalc32 allows control of the CAP2000+ Viscometer while providing automatic data capture and graphical display. Automate your CAP 2000+ Viscometer and generate flow curves quickly and easily. –Controls test parameters with powerful scripting capabilities–Looping functions for repetitive tasks–Automates data collection to save time–Reduces operator error–Math modeling for yield stress calculations, plastic index–Plot up to five data sets for comparisons

ApplicationsMEDIUM VISCOSITY Adhesives (hot melt) Coatings ResinsArchitectural Coatings Industrial Coatings StarchesAutocoats (Hi-performance) Inks (screen printing) SurfaceCreams Organisols UV CoatingsFood Products Paints Varnish Gels Paper CoatingsGums Plastisols

HIGH VISCOSITY Adhesives Gels Sealants Asphalt Inks (ballpoint, offset, lithographic) Sheet Molding CompoundChocolate Molasses TarsComposite Polymers Pastes Vinyl EstersEpoxies Roofing Compounds

Page 16: BEL Catalog 2008

1� T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

LVDV-IIIURVDV-IIIUHADV-IIIUHBDV-IIIU

MODEL Min.

VISCOSITYRANGE

cP(mPa•s)

Max. RPMNumber ofIncrements

6M40M80M

320M

SPEEDS

1†

100††

200††

800††

2.6K2.6K2.6K2.6K

.01-250

.01-250

.01-250

.01-250† 1 cP achieved with UL Adapter accessory. 15 cP on LV with standard spindles.†† Minimum viscosity is achieved with optional RV/HA/HB-1 spindle.M = 1 million K = 1 thousand cP = Centipoise mPa•s = Millipascal/seconds

Bi-directional RS-232 PC interface provides optional computer control and

automatic data gathering capability

Displayed info:–Viscosity (cP or mPa•s)–Temperature (°C or °F)–Shear Rate/Stress–% Torque–Speed/Spindle–Step Program Status–Math Model Calculations

2�00 Speeds to characterize a wide range of flow behavior

Built-in RTD Temperature Probe

Stand-alone programming: Enter test method steps, temperature

requirements, start program, see results on built-in display

Complete computer control using optional Rheocalc32 software lets

you control all aspects of rheological testing directly from the computer

Built-in math models for data analysis in stand-alone mode. E.g. Casson, Bingham, Power Law

Accuracy: ±1.0% of range

Repeatability: ±0.2%

The “all-in-one” tool to easily predict a material’s complete flow behavior

Analyze characteristics such as yield stress, flow curves,

(mixing, pumping, spraying), leveling and recovery

Download custom test programswith RheoLoader software(included with instrument)

DV-III Ultra Rheometer for measuring viscosity and yield stress

BROOKFIELD RHEOMETERS

Page 17: BEL Catalog 2008

1�

EZ-Yield Test Plots for Multiple Samples

LVRVHAHB5xHB

Pa dyne/cm2

SHEAR STRESSRANGE

5-1K10-2K40-8K

200-40K

.5-1001-2004-80020-4K

TORQUERANGE

Contact Brook�eld

DV-III Ultra CP The DV-III Ultra is available in a Wells/Brookfield Cone & Plate Version (p12)Must be ordered when instrument is first purchased.

Rheocalc32 Software OptionalGet total control of your instrument and test parametersAutomatically control and collect data with Rheocalc32 and a dedicated computer. Rheocalc32 can analyze data, generate multiple plot overlays, print tabular data, run math models and perform other time-saving routines. Data can be saved in the program or exported to Excel. –Controls test parameters with powerful scripting capabilities–NEW wizard for self-guiding creation of test programs–Looping functions for repetitive tasks–Automates data collection to save time–Math modeling for yield stress calculations, plastic index–Plot up to five data sets for comparisons

What’s Included?Instrument

� spindles (RV/HA/HB) (p39)

or 4 spindles (LV) (p39)

RheoLoader software E

EZ-Yield Software E

RTD Temperature Probe

Spindle Guard Leg*

Lab Stand Base

Carrying Case *Not applicable to HA or HB versions

Optional AccessoriesRheocalc32 Software E

NEW Ball Bearing Suspension (p3)

Viscosity Standards (p44)

RV/HA/HB-1 Spindle (p39)

EZ-Lock Spindle Coupling System (p3)

Temperature Bath (p2�)

Small Sample Adapter (p32)

UL Adapter (p34)

Thermosel (p30)

Helipath Stand with T-bar Spindles (p3�)

Spiral Adapter (p38)

DIN Adapter (p38)

Quick Connect/Extension Links (p43)

Vane Spindles (p3� & 42)

Protective Keypad Covers (p3)

RheoLoader Software IncludedCustomize your test criteria for routine product QC This exclusive Brookfield software allows you to create customized programs for your instrument, each with as many as 50 commands. Once a program is downloaded from a host computer, comprehensive viscosity tests can be run automatically in stand-alone mode.

EZ-Yield Software Included Yield tests can be performed with EZ-Yield software and vane spindles.

Page 18: BEL Catalog 2008

18 T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

PVS-B1-D-HCPVS-B2-D-HCPVS-B5-D-HCPVS-TA5B5-D-HC

BOB/STATORSAMPLE CUP

VISCOSITYRANGE

cP (mPa•s)

SHEARRATE(sec-1)

SAMPLEVOLUME

(mL)

VAPORVOLUME

(mL)1-3M

20-36M5-9M.5-1M

1.7N0.38N0.85N0.85N

235340

150

90909090

M = 1 million N = RPM mL = MilliliterHC = Hastelloy C

PVS Rheometer Ranges

PVSMODEL Min.

VISCOSITYRANGE*

cP(mPa•s)

Max. RPMNumber ofIncrements

36M

SPEEDS

.5 10K.05-1K* Ranges depend on “Bob” spindle selected.M = 1 million K = 1 thousand cP = Centipoise mPa•s = Millipascal/seconds

Robust Motor capable of speeds up to 1000 rpm

Vacuum to high pressure measurements up to 1,000 psi

Safety Relief Valve1000psi (high pressure)

Couette Geometry -Outside Cylinder Rotates, “Bob” inside remains stationary, generating shear rates up to 1�00 sec-1

RTD on the inner cylinder insures accurate sample temperature measurement

Hastelloy C cup and bobsfor operation in severe field environments

Avoids sample boil-off

Quick and easy setup in minutes

Low Shear Rate Viscosity (LSRV) measurement to .02 sec-1

Temperature conditions: from -40°C to +200°C

Test to industry standards

BROOKFIELD RHEOMETERS

PVS Rheometer1’ x 1’ x 2’ instrument for portable site-to-site mobility

Page 19: BEL Catalog 2008

19

Thermo Bath option for sample heating with small space requirement. Call for details.

Carrying Case for portability in the field

RheoVision Software IncludedFor automation and control of all test parametersSpecifically designed for sophisticated rheological analysis, RheoVision makes viscosity measurement under pressurized and temperature controlled conditions an easy task. Powerful scripting language provides simple to complex data collection programs including automatic calculation of yield stress using Bingham, Herschel-Bulkley, Power Law equations. –Enhanced graphing capabilities–Instantaneous flow curves–Built in math modeling–User-friendly ramp wizard for quick API testing–Seal history tracking feature

What’s Included?Instrument

Choice of spindle (bob) (p41)

Sample Cup (p41)

RheoVision software E

Carrying Case (shown below)

Optional AccessoriesViscosity Standards (p44)

Additional spindle (bobs) (p41)

Computer

Temperature Control Bath

Thermo Bath

Available with triple annulus geometry for increased sensitivity when measuring low viscosity fluids

ApplicationsFracturing FluidsDrilling MudsVolatile ChemicalsPetroleum ProductsBlack Liquor

Page 20: BEL Catalog 2008

20 T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

R/S CPS Models R/S-CPS Cone/Plate R/S-CPS Plate/PlateR/S Coaxial CylinderR/S-SST

MODEL Min.

VISCOSITYRANGE*

Max. RPMNumber ofIncrements

3.2M9.9M30M

SPEEDS

20201

>10K>10K>10K>10K

0.1-10000.1-10000.1-10000.1-1000

* Using spindles provided. Ranges can be expanded or reduced using accessories.

see page 23 for ranges

R/S-CPS Cone/Plate

R/S-CC Coaxial Cylinder

R/S-SST Soft Solids Tester

BROOKFIELD RHEOMETERS

R/S Plus Rheometersfor Controlled Rate/Stress Measurement

R/S represents the best that Brookfield has to offer — an instrument that operates both in controlled Rate (rpm) and controlled shear Stress (torque) modes. The Brookfield R/S Plus Rheometers out perform and offer greater flexibility than other rheometers in their class.

The R/S Plus series of rheometers is now available with enhanced encoder for increased measuring and control capabilities while maintaining sophisticated rheological analysis — all at an affordable price.

The R/S Plus is available in three configurations: Model R/S-CC (coaxial cylinder), Model R/S-CPS (cone and plate) and Model R/S-SST (soft solids tester with vane spindles) for a variety of samples.

All R/S Plus Rheometers have a rugged design for many years of trouble-free operation. Rapid spindle attachment and easy to clean surfaces ensure its use will save you time and money.

R/S Plus Rheometers include such unique features as:

E Wide torque range: 0.05 to 50 mNm

E Variable speed from 0.01 to 1000 rpm

E Stand-alone operation for quick single point evaluation or programmed tests using keypad

E PC interface for powerful capability of flow curve analysis, determination of yield stress and thixotropy when running Rheo2000 software

E Measurement of yield stress and strain, modulus and creep

E Test method sequencing capability to assess complete flow behavior of sample including rebuild/recovery evaluation after shearing

E Quality control mode enables tolerance bands to be placed around measure- ment data for immediate visual pass/fail determination

ApplicationsCoatings InksCosmetics PaintsCreams PastesGels Putties

ApplicationsChemicals Dairy Products Inks JuicesOilsPaints/CoatingsPolymer SolutionsSlurries

ApplicationsAdhesives Pastes Cosmetics Sealants Foods Viscous Polymers Gels

Page 21: BEL Catalog 2008

21

R/S-CPSR/S-CPS-P1R/S-CPS-P2R/S-CPS-E1

MODELBathPeltier P1Peltier P2Electronic

Description Temperature

Cone/Plate Temperature Control Options

-15° to 250°C0° to 135°C20° to 180°C60° to 250°C

See page 41 for spindle ranges and sample volumes.

User-friendly keypad and display for stand-alone operation

Quick and easy Cone/Plate

or Plate/Plate Gap Setting

Precision Height Gauge Shows Actual Gap Setting

Very small sample size permits rapid test set up and clean up (p41)

Quick Connect Spindle Coupling

Temperature Control via Brookfield Bath, Peltier Device or Electrical Heating

Controlled shear stress/shear rate operation makes it easy to study

material behavior from initial yield to flow curve response (p41)

Rapid temperature control of plate with Peltier option provides quick

profiling of viscosity vs. temperature

Choice of several cone spindles to accommodate all sample and measurement requirements (p41)

Plate/Plate measurement capability for highly filled sample

What’s Included?Instrument

Choice of Spindle: cone spindles, plate spindles (p41)

Optional AccessoriesRheo2000 Software H

Viscosity Standards (p44)

Additional Spindles (p41)

Water Baths (p2�)

Solvent Trap

Thermal Barrier* *two part chamber provides thermal isolation of the measurement zone

R/S-CPS RheometerCone/Plate & Plate/Plate Systems for small samples

Rheo2000 Software OptionalFor programmed control and data analysis with a computerProgram shear stress or shear rate, temperature and test time requirements, and let your PC do the data collection and analysis work for you! Mathematical data analysis models included: Newton, Bingham, Casson, Herschel-Bulkley, Ostwald, Steiger-Ory

Page 22: BEL Catalog 2008

22 T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

Immersion ChambersFTK Water Jacket ChambersDisposable Chambers

Chambers Temperature

Sample Chamber Options

See page 41 for spindle ranges and sample volumes.

-20°C to 180°C-20°C to 180°C-20°C to 180°C

User-friendly keypad and display

Small sample size facilitates rapid temperature control during testing

Quick Connect Coupling

Stand-alone operation permits use on production floor

Coaxial sensing geometry for single point QC or full

rheological profiling

Chambers

Water Jacket

Coaxial Cylinder Spindles

Controlled shear stress/shear rate operation makes it easy to study

material behavior from initial yield to flow curve response (p41)

BROOKFIELD SPECIALTY INSTRUMENTS

R/S-CC Coaxial Cylinder Rheometerfor accurate shear rate control and absolute viscosity measurement

What’s Included?Instrument Choice of Spindle/Chamber

Optional AccessoriesRheo2000 Software H Viscosity Standards (p44) Additional Spindles (p41) Disposable Chambers

Quick Connect Bayonet Chambers FTK Water Jacket for Temperature Control PT-E Immersion Temperature Sensor PT100 KE Cooling Device* *required for temperatures over 90°C

Rheo2000 Software OptionalFor programmed control and data analysis with a computerProgram shear stress or shear rate, temperature and test time requirements, and let your PC do the data collection and analysis work for you! Mathematical data processing models included: Newton, Bingham, Casson, Herschel-Bulkley, Ostwald, Steiger-Ory. For integrated temperature control, contact Brookfield for details.

Page 23: BEL Catalog 2008

23

V80-40V60-30V40-20V30-15V20-10V10-5

6-20015-505

51-1700120-4000

408-136003276-109200

Spindle Shear Stress Range (Pa)

R/S-SST Spindle Ranges

Custom vane spindles available. Call for details.

Quantifies meaningful properties like wobbliness, sloppiness,

consistency and texture

Vane Spindle Geometry– Quick-Connect coupling– Easy-to-test method– Allows spindle insertion without compromising sample structure

Smooth Height Adjustment for easy insertion of spindle

into sample without disrupting structure of sample

Provides Viscoelastic Data– Yield Stress– Shear Modulus– Recovery– Creep

Rugged base with adjustable sample

container clamp for precise positioning of sample

Coaxial Cylinders can also be used for complete

flow curve analysis

R/S-SST Soft Solids Testerfor pastes, slurries and materials with particulates

What’s Included?Instrument with adjustable height

Choice of one Vane Spindle (p41)

Adjustable Sample Container Clamp on Lab Stand

Optional AccessoriesRheo2000 Software with Soft Solids Module H

Viscosity Standards (p44)

Additional Vane Spindles (p41)

Coaxial Cylinder Spindles (p41)

Rheo2000 Software Optionalwith Soft Solids Module

Software provides visual information and test data on viscoelastic behavior such as viscous creep and recovery

Quality Control Mode enables tolerance bands to be placed around

measurement data for immediate visual pass/fail determination

Page 24: BEL Catalog 2008

24 T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

EZ-Yield Software included for use with a PC

Excellent repeatability

Affordable

Displayed Information:– Yield Stress Value (Pascal)– % Torque

Temperature Probe included (not shown)

Vane Spindle Geometry works with thin to highly viscous materials(Does not disturb sample during spindle insertion)

User-friendly Keypadand display for

stand-alone operation

Simple to use

Choice of Spindle Sizesto fit any sample container

Ideal for QC

BROOKFIELD SPECIALTY INSTRUMENTS

YR-1 Yield Stress Rheometera low-cost QC tool to enhance material characterization

Page 25: BEL Catalog 2008

25

Note: 1. 1 Pa = 10 dyne/cm2 2. Viscosity Range is given at rotational speed of 10 RPM 3. 5xHB is the highest torque range available 4. Not for use with DV-E ViscometersM = 1 million K = 1 thousand Pa = Pascal cP = Centipoise mPa•s = Millipascal/seconds

Vane Spindle Ranges

V-71V-72V-73V-74V-75V-71V-72V-73V-74V-75V-71V-72V-73V-74V-75V-71V-72V-73V-74V-75

1/4RV1/4RV1/4RV1/4RV1/4RV

RVRVRVRVRVHAHAHAHAHAHBHBHBHBHB

TORQUERANGE

.125-1.25.5-5

2.5-2525-25010-100

.5-52-20

10-100100-1K40-400

1-104-40

20-200200-2K80-800

4-4016-16080-800800-8K

320-3.2K

SHEAR STRESSRANGE (Pa)SPINDLE

Applications1/4 RV SERIES — VERY LOW YIELD Juices Beverages

RV SERIES — LOW YIELD Food Products Shampoo Gels Yogurt Hair Gels

HB SERIES — MEDIUM YIELD Chocolate Lotions Food Products Ketchup Hand Cream Personal Care Products Jelly Toothpaste

5xHB SERIES — HIGH YIELD Adhesive Caulk Pastes Cheese Spread Peanut Butter Fruit Preserves Shortening

EZ-Yield software features a simple parameter menu for set up of 10 different test programs. Test parameters include: test number and name, spindle #, immersion mark, pre-shear (rpm), wait time before test startup, run speed (rpm), and low & high yield control limits (Pa) for QC use.

Streaming data can be viewed and test data — torque vs. time, stress vs. strain — is displayed in both tabular and graphical formats on a PC when using EZ-Yield software.

YR-1 Vane Spindles V-�2 and V-�3 vane spindles with case are supplied with YR-1. V-�1 (large), V-�4 (small) and V-�5 (small) vane spindles are optional.

EZ-Yield Data Collection EZ-Yield Test Plotsfor Multiple Samples

EZ-Yield Software IncludedEasily program and capture dataEZ-Yield software is included with all YR-1 Yield Stress Rheometers and allows for simple data collection on a PC. Collecting data affords you a record of all your valuable testing results.

What’s Included?Instrument

V-�2 & V-�3 Vane Spindles (p3� & 42) H

EZ-Yield Software E

Carrying Case

Optional AccessoriesRTD Temperature Probe

V-�1, V-�4 & V-�5 Vane Spindles (p3� & 42)

Viscosity Standards (p44)

Temperature Bath (p2�)

Protective Keypad Covers (p3)

Quick Action Lab Stand (p3)

Page 26: BEL Catalog 2008

2� T: 800.�28.8139 or 508.94�.�200 F: 508.94�.�2�2 www.brookfieldengineering.com

ApplicationsPaints Coatings AdhesivesInks Pastes

Accuracy: ±1.0% of range

Repeatability: ±0.5%

Easy to useno weights, simplifies an established test procedure

LED Display Info:–Krebs Units–Gram Units

(Weight)–Centipoise*

Select Krebs or Grams or Centipoise

ASTM D5�2 Compatible (industry specification)

Adapter provided for 1/2 Pint, Pint, &

Quart Containers

Lock-In Test Results with Hold Switch

Standard Krebs Spindle

Measurement range: 40 to 141 KU, 32 to 1099 gm,

and 2� to 52�4 cP*

Printer Connection for automatic test

documentation

KU-2 Viscometerfor Paints, Coatings, and Inks

What’s Included?Instrument

Krebs-type Spindle (p42)

Communications Port for Printer

Adapter for Quart, Pint and Half-Pint Cans†

Optional AccessoriesAir Purge

Paste Spindle (p42)

*Centipoise values based on the conversion from Krebs Units as defined in the ASTM D5�2.

†Adapters which accommodate metric size cans are available for an additional fee — contact Brookfield to discuss your requirements

BROOKFIELD SPECIALTY INSTRUMENTS

Page 27: BEL Catalog 2008

27

** Tap water connection required.N/A - Not Applicable

† Temperature stability may vary depending on bathvolume, surface area, insulation and type of �uid

* For use at lower temperatures, use the built-in tap water cooling, or use model TC-351 Cooler for control to -20°C. FOR TEMPERATURES HIGHER THAN 80°C, PLEASE CONTACT BROOKFIELD FOR FLUID RECOMMENDATIONS.

Note: 1. Specify voltage and frequency when ordering.

Tem

pera

ture

Ran

ge Lo

wTe

mpe

ratu

re

Ran

ge H

igh

Cont

rolle

r

Cool

ing

Tem

pera

ture

Sta

bilit

y†

Digita

l Rea

dout

/

Acc

urac

y

Rese

rvoi

r C

apac

ity

Inte

rnal

Wor

k Are

a

DxWxH

(inch

es)

Overa

ll D

imen

sions

DxW

xH (in

ches

)

Wei

ght

(Gro

ss)

Temperature Baths

MODEL

TC-602PTC-602DTC-502PTC-502DTC-202P*TC-202D*TC-102P*TC-102D*TC-351

-20°C-20°C-20°C-20°C-20°C-20°C-20°C-20°C-20°C

+200°C+150°C+200°C+150°C+150°C+150°C+200°C+150°C

N/A

ProgrammableDigital

ProgrammableDigital

ProgrammableDigital

ProgrammableDigital

N/A

RefrigeratedRefrigeratedRefrigeratedRefrigeratedTap Water**Tap Water**Tap Water**Tap Water**

N/A

0.01°C0.05°C0.01°C0.05°C0.01°C0.05°C0.01°C0.05°C

N/A

LCD/±.25LED/±.5

LCD/±.25LED/±.5

LCD/±.25LED/±.5

LCD/±.25LED/±.5

N/A

6.0 liters6.0 liters6.0 liters6.0 liters

10.0 liters10.0 liters6.0 liters6.0 liters

N/A

51/4 x 51/4 x 51/2

51/4 x 51/4 x 51/2

51/4 x 51/4 x 51/2

51/4 x 51/4 x 51/2

51/4 x 81/2 x 73/451/4 x 81/2 x 73/451/4 x 51/4 x 51/2

51/4 x 51/4 x 51/2

N/A

70 lbs64 lbs78 lbs67 lbs39 lbs33 lbs29 lbs23 lbs72 lbs

153/4 x 81/4 x 221/2

153/4 x 81/4 x 221/2

153/4 x 183/4 x 17153/4 x 183/4 x 17

151/2 x 107/8 x 143/4151/2 x 107/8 x 143/4

141/4 x 81/4 x 14141/4 x 81/4 x 14

17 x 14 x 14

Full Graphic DisplayProgrammable Controller shown

Temperature ControlYou need to control sample temperature

during viscosity measurements

BROOKFIELD TEMPERATURE CONTROL

Programmable Controllers offer the highest level of performance, flexibility, and control for the most demanding applications. Full graphic display with help menus Intuitive, one-touch control Time and temperature programming with data logging RS-232 Interface – Use with Rheocalc™ (p7) or RheoVision™ (p19) Software Built-in service reminder Five speed pump control Digital Controllers have easy-to-use controls. Just dial in your set-point and push a button, you’re done! LED readout displays set point and fluid temperature 3 adjustable temperature pre-sets Unique rotary control allows rapid set-point adjustments Two speed pump

Temperature control during viscosity measurement helps insure accurate test results. The addition of a Brookfield circulating water bath is a smart investment. The Brookfield TC Series Circulating Water Baths are uniquely configured for use with your Brookfield Viscometer or Rheometer.

Page 28: BEL Catalog 2008

28 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

ProgrammableController shown

ProgrammableController shown

TC-502 Circulating Water BathRefrigeratedAvailable with Programmable Controller or enhanced Digital Controller Provides stand-alone operation – No tap water required Easy control of set-point Configured to measure viscosity directly in the bath – accommodates 600 mL beaker Programmable Controller version is designed to automate sample temperature control Built-in circulator to pump to external devices

TC-602 Circulating Water BathCompact-RefrigeratedAvailable with Programmable Controller or enhanced Digital Controller Compact — small “footprint” on your lab bench, only 8 1/4 inches wide Specifically designed for use with water-jacketed devices–Wells-Brookfield Cone/Plate–Small Sample Adapter Accessory–Ultra-Low Adapter Accessory–R/S-CC Rheometer–R/S-CPS Rheometer Provides stand-alone operation – no tap water is required Easy control of set-point Programmable Controller version is designed to automate sample temperature control

BROOKFIELD TEMPERATURE CONTROL

Page 29: BEL Catalog 2008

29

EnhancedDigital

Controllershown

EnhancedDigital

Controllershown

TC-102 Circulating Water BathNon-Refrigerated

Available with Programmable Controller or enhanced Digital Controller Configured for measuring multiple samples directly in the bath Work area accommodates 600 mL and 1000 mL beakers (cover is removable for large sample container requirements) Built-in tap water cooling coil Built-in circulator pump

Water Bath AccessoriesHigh Temperature Fluid 1 gal. DC510 50°C to 150°C DC550 100°C to 200°C Heat transfer fluids provide superior thermal stability

Low Temperature Fluid 1 gal. Dynalene -50°C to +58°C Excellent low temperature performance Little or no evaporation For continuous low temperature applications

Algaecide 8 oz. Keeps circulator baths clean, odor free and resists black algae Economical 10-15 drops per gallon

Ethylene Glycol 1 gal. -20°C to +100°C Laboratory grade bath fluid Normally mixed with water at 50:50 ratio

18” Lab Stand Rod This optional accessory is available for increased instrument height

TC-202 Circulating Water BathNon-Refrigerated

TC-351 Cooler Not Shown

Eliminates tap water requirements on non-refrigerated baths Increases lower range of most baths to –20°C

Available with Programmable Controller or enhanced Digital Controller Compact – small “footprint” Built-in circulator pump Built-in tap water cooling coil Perfect choice for use with Brookfield water-jacketed devices–Wells-Brookfield –Cone/Plate–Small Sample Adapter –Accessory–Ultra-Low Adapter –Accessory–R/S-CC Rheometer–R/S-CPS Rheometer

Page 30: BEL Catalog 2008

30 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

Provides control of sample temperature up to +300°C

Thermo Container (Heating Chamber)

Programmable Temperature Controller offers single set point or up to 10

programmable set points.

Computer Controlledwhen used with DV-II+Pro or DV-III Ultra

and Rheocalc32 Software

Temperature Ramping between set points is possible if used with

Rheocalc (DV-III Ultra & DV-II+Pro) Software Note: Requires optional cable HT-106

Compatible with standard

Brookfield Viscometers

and DV-III Ultra Rheometers

Note: requires optional cable DVP-141

The difficulty with viscosity measurements of hot melts and liquids at elevated temperatures has been in maintaining accurate temperature control that is consistent from sample to sample so that meaningful data could be obtained. The Brookfield Thermosel solves this problem by providing a stable, precisely controlled sample environment. This, together with the inherent accuracy of the Brookfield Viscometers, is fundamental to the Thermosel System, which produces viscosity measurements that are not only accurate but entirely reproducible. Several factors contribute to the stable environment: Non-fluctuating temperature control Small sample volume and insulated sample chamber which reduces temperature gradients within the sample The rotating spindle, which acts as a built-in stirring device The test procedure is quite straightforward. Once familiar with the system, unskilled operators can easily produce accurate, reproducible data.

BROOKFIELD TEMPERATURE CONTROL

What’s Included?Choice of one SC4 SpindleSpecify when ordering

Alignment BracketThermo Container with safety guard and insulating cap1 Removable Sample Chamber (p41)

5 Disposable Sample Chambers (p41) Order additional chambers in quantities of 100, HT-2DB-100

18” Lab Stand RodExtracting ToolsTemperature Controller with an RTD probe

ApplicationsHot Melts AsphaltWax Polymers

Thermosel™

for Elevated Temperature Testing

Page 31: BEL Catalog 2008

31

MODEL

Not applicable for historical reasons. However, it is possible to use the above spindles with any of these

instruments. Digital Viscometers/Rheometers will

automatically calculate viscosity. Please contact Brook�eld or an authorized dealer if you require information on viscosity range.

Not applicable for historical reasons. However, it is possible to use the above spindles with any of these instruments.

Digital Viscometers/Rheometers will automatically calculate viscosity. Please contact Brook�eld or an authorized dealer

if you require information on viscosity range.

*Optional disposable SC4-27D spindle is available in quantities of 100, Part No. SC4-27D-100. Requires special chuck/closer, Part No. SC4-DSY, for attachment to viscometer.

**The 81 spindle, Part No. HT-DIN-81, works in an HT-2 or HT-2DB chamber.

LVDV-IIIULVDV-II+PLVDV-IPLVDVELVTRVDV-IIIURVDV-II+PRVDV-IPRVDVERVTHADV-IIIUHADV-II+PHADV-IPHADVEHATHBDV-IIIUHBDV-II+PHBDV-IPHBDVEHBT

1.2-30K1.5-30K3-10K3-10K5-10K

12-300K15-300K30-100K30-100K50-100K

24-600K30-600K60-200K60-200K

100-200K20-500K25-500K50-170K50-170K50-100K40-1M50-1M

100-300K100-300K100-200K160-4M200-4M

400-1.3M400-1.3M400-800K

100-2.5M125-2.5M250-830K250-830K250-500K200-5M250-5M

500-1.7M500-1.7M500-1M

800-20M1K-20M2K-6.7M2K-6.7M2K-4M

200-5M250-5M

500-1.7M500-1.7M500-1M

400-10M500-10M1K-3.3M1K-3.3M1K-2M

1.6K-40M2K-40M

4K-13.3M4K-13.3M

4K-8M

400-10M500-10M1K-3.3M1K-3.3M1K-2M

800-20M1K-20M2K-6.7M2K-6.7M2K-4M

3.2K-80M4K-80M

8K-26.7M8K-26.7M8K-16M

SC4-188mL

1.32N

SPINDLESAMPLE VOLUMESHEAR RATE (sec-1

SC4-3110mL.34N

SC4-349.5mL.28N

SC4-218mL.93N

SC4-27*10.5mL

.34N

SC4-2811.5mL

.28N

SC4-2913mL.25N

1.0-10K3.4-10K3.4-10K

N/A5.7-10K

14.6-10K36.5-10K36.5-10K

N/A36.5-10K29.2-10K73.0-10K73.0-10K

N/A73.0-10K

116.8-10K292.0-10K292.0-10K

N/A292.0-10K

HT-DIN-81**7mL

1.29N

Alignment Bracket ensures concentricity of spindle and sample chamber.

Extracting Tool enables the sample chamber to be handled easily and safely.

Additional Information

Other components supplied include sample chamber holder, RTD probe, insulating cap, coupling link, coupling nut and choice of SC4 spindle.

Option: Disposable Sample Chamber with Optional Disposable Spindle SC4-27D* is ideal for asphalts or any difficult-to-clean material.Order disposable SC4-27D spindle in quantities of 100, Part No. SC4-27D-100. Requires special chuck/closer, Part No. SC4-DSY, for attachment to viscometer. Order disposable HT-2DB chambers in quantities of 100, Part No. HT-2DB-100.

Page 32: BEL Catalog 2008

32 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

Standard Sample Chamber with embedded

temperature probe provides direct temperature

measurement of sample

Disposable Sample Chamber(Requires SSA-DCU Water Jacket)

8.

9.

6.

5.

BROOKFIELD ACCESSORIES

Small Sample Adapter for rheological evaluation where sample volume is limited

The Small Sample Adapter provides a defined geometry system for accurate viscosity measurements at precise shear rates. Consisting of a cylindrical sample chamber and spindle, the Small Sample Adapter is designed to measure small sample volumes of 2 to 16 mL, and easily attaches to all standard Brookfield Viscometers/Rheometers. Removable Sample Chamber The design of the Small Sample Adapter allows the sample chamber to be easily changed and cleaned without disturbing the set-up of the viscometer or temperature bath. This means that successive measurements can be made under identical conditions. Temperature Control The sample chamber fits into a water jacket so that precise temperature control can be achieved when the Brookfield circulating temperature bath is used. The stirring action of the rotating spindle, plus the small sample volume, helps to keep the temperature gradient across the sample to a minimum. Direct readout of sample temperature is provided using sample chambers with optional embedded RTD sensor connected to the DV-I Prime and DV-II+Pro Viscometers and the DV-III Ultra Rheometer. Working temperature range for the Small Sample Adapter is from –15°C to 100°C. Cylindrical Geometry The Small Sample Adapter’s coaxial cylinder geometry provides extremely accurate viscosity measurements at defined shear rates. Disposable Sample Chambers Disposable 13R chambers, for hard-to-clean materials, are available in a kit that comes complete with 100 chambers and special-sized water jacket (Part No. SSA-DCU). Additional disposable chambers can be purchased in quantities of 100 (Part No. SC4-13RD-100).

Complete system shows the DV-II+Pro Viscometer and Small Sample Adapter

with Circulating Water Bath for temperature control.

Page 33: BEL Catalog 2008

33

Not applicable for historical reasons. However, it is possible to use the above spindle/chamber combinations with any of these

instruments. Digital Viscometers/Rheometers will automatically calculate viscosity. Please contact Brook�eld or an authorized

dealer if you require information on viscosity range.

Not applicable for historical reasons. However, it is possible to use the

above spindle/chamber combinations with any of these instruments. Digital

Viscometers/Rheometers will automatically calculate viscosity. Please contact Brook�eld or an authorized dealer if you require information on viscosity range.

N/A = Not applicable for historical reasons. However, it is possible to use any spindle/chamber combination with any torque range. Digital viscometers/rheometers will automatically calculate viscosity.

* ExamplesSC4-13R Sample Chamber SC4-13RP Sample Chamber with RTD temperature probeSC4-13RPY Sample Chamber with RTD temperature probe and cable to viscometer/rheometer SC4-13RD-100 Disposable Sample Chamber available in packages of 100

** Disposable chamber available in 13R size and requires SC4-45YD water jacket

Spin

dle SC

4-18

Sam

ple C

ham

ber*

SC4-

13R(

P)

Sam

ple V

olum

e 6.7m

L

Shea

r Rat

e (se

c-1 ) 1

.32N

Spin

dle SC

4-34

Sam

ple C

ham

ber*

SC4-

13R(

P)

Sam

ple V

olum

e 9.4m

L

Shea

r Rat

e (se

c-1 ) .2

8N

Spin

dle SC

4-25

Sam

ple C

ham

ber*

SC4-

13R(

P)

Sam

ple V

olum

e 16.1

mL

Shea

r Rat

e (se

c-1 ) .2

2N

Spin

dle SC

4-27

Sam

ple C

ham

ber*

SC4-

13R(

P)

Sam

ple V

olum

e 10.4

mL

Shea

r Rat

e (se

c-1 ) .3

4N

Sam

ple C

ham

ber*

SC4-

13R(

P)

Sam

ple V

olum

e 9.0m

L

Shea

r Rat

e (se

c-1 ) .3

4N

Spin

dle SC

4-31

Sam

ple C

ham

ber*

SC4-

8R(P

)

Sam

ple V

olum

e 4.2m

L

Shea

r Rat

e (se

c-1 ) .2

9N

Spin

dle SC

4-16

Sam

ple C

ham

ber*

SC4-

13R(

P)

Sam

ple V

olum

e 7.1m

L

Shea

r Rat

e (se

c-1 ) .9

3N

Spin

dle SC

4-21

Spin

dle SC

4-28

Sam

ple C

ham

ber*

SC4-

13R(

P)

Sam

ple V

olum

e 11.0

mL

Shea

r Rat

e (se

c-1 ) .2

8N

Sam

ple C

ham

ber*

SC4-

7R(P

)

Sam

ple V

olum

e 3.8m

L

Shea

r Rat

e (se

c-1 ) .4

8N

Spin

dle SC

4-15

Sam

ple C

ham

ber*

SC4-

13R(

P)

Sam

ple V

olum

e 13.5

mL

Shea

r Rat

e (se

c-1 ) .2

5N

Spin

dle SC

4-29

Spin

dle SC

4-14

Sam

ple C

ham

ber*

SC4-

6R(P

)

Sam

ple V

olum

e 2.1m

L

Shea

r Rat

e (se

c-1 ) .4

0N

MODEL

LVDV-IIIULVDV-II+PLVDV-IPLVDVELVTRVDV-IIIURVDV-II+PRVDV-IPRVDVERVTHADV-IIIUHADV-II+PHADV-IPHADVEHATHBDV-IIIUHBDV-II+PHBDV-IPHBDVEHBT

1.2-30K1.5-30K3-10K3-10K5-10K

12-300K15-300K30-100K30-100K50-100K

20-500K25-500K50-170K50-170K50-100K40-1M50-1M

100-300K100-300K100-200K160-4M200-4M

400-1.3M400-1.3M400-800K

100-2.5M125-2.5M250-830K250-830K250-500K200-5M250-5M

500-1.7M500-1.7M500-1M

800-20M1K-20M2K-6.7M2K-6.7M2K-4M

200-5M250-5M

500-1.7M500-1.7M500-1M

400-10M500-10M1K-3.3M1K-3.3M1K-2M

1.6K-40M2K-40M

4K-13.3M4K-13.3M

4K-8M

400-10M500-10M1K-3.3M1K-3.3M1K-2M

800-20M1K-20M2K-6.7M2K-6.7M2K-4M

3.2K-80M4K-80M

8K-26.7M8K-26.7M8K-16M

24-600K30-600K60-200K60-200K

100-200K

48-1.2M60-1.2M

120-400K120-400K200-400K

192-4.8M240-4.8M800-1.6M800-1.6M800-1.6M

200-5M250-5M

500-1.7M500-1.7M500-1M

400-10M500-10M1K-3.3M1K-3.3M1K-2M

1.6K-40M2K-40M

4K-13.3M4K-13.3M

4K-8M

500-12.5M625-12.5M1.25K-4.2M1.25K-4.2M1.25K-2.5M

1K-25M1.25K-25M2.5K-8.3M2.5K-8.3M2.5K-5M4K-100M5K-100M

10K-33.3M10K-33.3M10K-20M

1.

2.

3.

7.

4.

What’s Included? 1. Water Jacket 2. Locating Channel Assembly 3. Choice of one SC4 Spindle* 4. Choice of one SC4 Sample Chamber* 5. Insulating Cap 6. Extention Link with Coupling Nut Storage Case (not shown)*Specify when ordering

Optional Accessories 7. Embedded RTD temperature Probe in Chamber 8. SC4-13RD Disposable Sample Chambers (p42) Requires special water jacket

9. Temperature Bath (p27)

For more info on Small Sample Adapter Accessory Kits visit our website.

Water jacket allows rapid and precise temperature control of sample

Sample chamber easily changed - slides into water jacket and locks in place

Simultaneous sample temperature measurement is possible by ordering embedded temperature probe in sample chamber

Optional disposable chamber also available

Page 34: BEL Catalog 2008

34 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

K = 1 thousand

LVT, LVDV-ELVDV-IP, LVDV-II+P

LVDV-IIIU1.0 - 2K

RVTRVDV-ERVDV-IP6.4 - 2K

RVDV-II+PRVDV-IIIU

3.0 - 2K

HATHADV-EHADV-IP12.8 - 2K

HADV-II+PHADV-IIIU

6.0 - 2K

HBTHBDV-EHBDV-IP51.2 - 2K

HBDV-II+PHBDV-IIIU24.0 - 2K

Reduces measuring range to as low as 1 cP, depending on viscometer used Simple attachment to a standard Brookfield Viscometer or DV-III Ultra Rheometer Small sample size: 16 mL Cylindrical geometry provides defined shear rates for detailed product analysis Removable cap of low density polyethylene can be considered disposable for one-time use if required Stainless steel parts are easily cleaned

BROOKFIELD ACCESSORIES

The Brookfield UL Adapter is used with any standard Brookfield Viscometer and Rheometer to make accurate and reproducible measurements on low viscosity materials. Newtonian and non-Newtonian materials can be measured. It is most commonly used with the LV series instrument (at 60 rpm, these models have a full scale range of 1-10 cP with the UL Adapter). The UL Adapter consists of a precision cylindrical spindle rotating inside an accurately machined tube. Its rheologically correct cylindrical geometry provides extremely accurate viscosity measurements and shear rate determinations. The tube has a removable end cap which allows the open ended tube to be used in a beaker or tank. With the cap in place, the closed tube can be immersed in a temperature bath or used with the ULA-40Y water jacket for precise temperature control. Working temperature range is from –15°C to 100°C.

Why replace your current UL Adapter? The new design saves a significant amount of time on set up and tear down of equipment. The new spindle with universal connector is easier to thread onto the viscometer. The entire assembly can remain in place between tests with only the chamber being removed to prepare the next sample for testing.

Enhanced UL Adapter ideal for low viscosity materials

Page 35: BEL Catalog 2008

35

Detail of UL Adapter: 1. Locating Channel Assembly, 2. Water Jacket, 3. Chamber Tube, 4. Collar with thumbwheel, 5. Tube End Cap, 6. Spindle with universal coupling

Quick & Easy Design Saves TimeQuick & easy attachment of spindle: Longer coupling nut for better grip and twist action to connect spindle to viscometer. Redesigned bracket for attaching ULA assembly to viscometer. Provides more clearance for finger grip on coupling nut.

Quick & easy removal of chamber: Simply loosen thumbwheel, chamber slides down and out. Permits rapid testing of multiple samples by swapping out chambers. Choice of leaving spindle attached to viscometer or disconnecting spindle and removing it with chamber. Water jacket sleeve remains in place attached to viscometer while chamber and/or spindle only are removed. Saves set up time for the operator.

Unique ULA Assembly Design Provides Multiple Benefits: Sturdy collar attaches to locating channel assembly which is connected to viscometer pivot cup. Sample chamber is held firmly in place by the collar which provides proper alignment for the spindle rotation within the chamber. Universal coupling nut on spindle ensures firm connection with viscometer and automatic self-centering of spindle in chamber during rotation. Direct immersion of chamber in temperature bath is quick and easy. Water jacket grips slide over collar and operator manually aligns the collar/jacket assembly to allow easy insertion of chamber containing sample to be tested.

What’s Included?Locating Channel Assembly

Spindle (304 s/s) (p40) with universal coupling nut

Collar assembly with thumbwheel

Water Jacket

Chamber Tube

Tube End Caps (package of 6)

Optional Accessories

1.2. 3.

4.5.

6.

Closed Tube andSpindle made from 316 s/s

Page 36: BEL Catalog 2008

36 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

LV Viscosity RangeRV Viscosity RangeHA Viscosity RangeHB Viscosity Range

156 - 3,120K2K - 20M4K - 40M

16K - 160M

156 - 9,360K2K - 100M4K - 200M

16K - 800M

156 - 9,360K2K - 100M4K - 200M

16K - 800M

DIAL, DV-E, DV-IP DV-II+P DV-IIIU

BROOKFIELD ACCESSORIES

For viscosity/consistency measurement of gels, pastes, creams, putty, gelatin and other non-flowing substances. A Brookfield Viscometer or Rheometer is mounted on the Helipath drive motor and a T-bar spindle is attached to the viscometer using a special coupling. The drive motor slowly lowers or raises the viscometer so that the T-bar spindle creates a helical path through the test sample thus eliminating the problem of “channeling”. Compatible with standard Brookfield Viscometers and DV-III Ultra Rheometers Simple to set up and clean Provides a solution for hard-to-measure materials Complete with drive motor, 6 T-bar spindles with coupling, case, lab stand, rod and base

Helipath Stand designed for measurement of non-flowing substances

The Helipath Stand can be used with any standard Brookfield Viscometer model, and is supplied complete with a set of six T-bar spindles and a special coupling.

Page 37: BEL Catalog 2008

37

Note: 1. 1 Pa = 10 dyne/cm2 2. Viscosity Range is given at rotational speed of 10 RPM 3. 5xHB is the highest torque range available 4. Not for use with DV-E Viscometers

Vane Spindle Ranges

V-71V-72V-73V-74V-75V-71V-72V-73V-74V-75V-71V-72V-73V-74V-75V-71V-72V-73V-74V-75V-71V-72V-73V-74V-75

LVLVLVLVRVRVRVRVRVHAHAHAHAHAHBHBHBHBHB

5xHB5xHB5xHB5xHB5xHB

TORQUERANGE

.188-1.88

.938-9.389.38-93.83.75-37.5

.5-52-20

10-100100-1K40-400

1-104-40

20-200200-2K80-800

4-4016-16080-800800-8K

320-3.2K20-20080-800

400-40004K-40K

1.6K-16K

SHEAR STRESSRANGE (Pa)

104.04-1.04K502-5.02K5.09-50.9K

1.996K-19.96K262-2.62K

1.11K-11.1K5.35K-53.5K54.3K-543K21.3K-213K524-5.24K

2.22K-22.2K10.7K-107K

108.6K-1.086M42.6K-426K

2.096K-20.96K8.88K-88.8K42.8K-428K

434.4K-4.344M170.4K-1.704M10.48K-104.8K

44.4K-444K214K-2.14M

2.172M-21.72M852K-8.52M

VISCOSITY RANGESPINDLE

NOT RECOMMENDED FOR USE ON LV TORQUE

…for use with paste-like materials, gels and fluids where suspended solids migrate away from the measurement surface of standard spindles.Minimal disruption of sample during spindle immersion

Keeps particles in suspension during testing cycle

Viscosity data includes complete flow curve analysis when software is used

Provides information on yield behavior at low rotational speeds

Follows industry recommendations on length/diameter ratios for vane spindles

3-piece spindle set for versatile range capability

Optional V-74 and V-75 spindles for even greater range capability and immersion into small size sample containers

Brookfield Vane Spindle Set Includes V-71, V-72, and V-73 vane spindles. See the individual specifications in the spindle section. (p42) Optional V-74 and V-75 spindles are smaller in size than V-73.

Vane Spindles for foods, cosmetics, sealants…

The instrument shown is a DV-II+Pro. These spindles also work well with other Brookfield Viscometers.

V-73

V-71

V-72

Page 38: BEL Catalog 2008

38 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

LVT1.9 - 37.9K

LVDV-ELVDV-IP

1.2 - 37.9K

LVDV-II+PLVDV-IIIU1.0 - 50K

RVTRVDV-ERVDV-IP

12.2 - 50K

RVDV-II+PRVDV-IIIU5.0 - 50K

HATHADV-EHADV-IP

24.4 - 50K

HADV-II+PHADV-IIIU10.0 - 50K

HBTHBDV-EHBDV-IP

97.6 - 50K

HBDV-II+PHBDV-IIIU40.0 - 50K

Complies with DIN 53019 requirements for test geometry. DIN is the German equivalent to the U.S. ASTM Standards. Designed to provide an alternative for those customers having limited sample volume. Requires 16 mL to 20 mL sample size. Cylindrical geometry provides defined shear rates. Comes with three spindles and chambers for measurement range of 1 to 50,000 cP.

BROOKFIELD ACCESSORIES

DIN Adapter

Spiral AdapterDesigned for measuring the viscosity of heavy paste-like materials such as solder paste, cosmetics, pharmaceuticals, food products and other non-flowing products. Provides variable shear rates for detecting pseudo plastic and thixotropic behavior. The spiral adapter is mounted onto a Brookfield Viscometer; with the chamber immersed in the test sample and the motor turned on, material is “pumped thru” and reaches a steady flow rate. Shear rate is 0.677 sec-1 per rpm.

Compatible with standard Brookfield Viscometers and DV-III Ultra Rheometers Compatible with electronics industry solder paste specifications Complete with chamber, two spindles, assembly clamp and case Note: RV/HA/HB torque ranges recommended

Spiral AdapterRanges cP(mPa•s)LV SeriesRV SeriesHA SeriesHB Series

K = 1 thousand M = 1 million cP = CentipoisemPa•s = milliPascal•seconds

to 100Kto 1.1Mto 2.2Mto 9.0M

Page 39: BEL Catalog 2008

39

(available as an option)

* Based on standard RV/HA/HB speeds .5-100 RPM.Note: LV and RV/HA/HB spindles are supplied in 302 stainless steel. Optional 316 stainless or te�on coated spindles are available** This spindle available as an option

M = 1 million K = 1 thousand

SPINDLERV-1**HA/HB-1**RV-2HA/HB-2RV/HA/HB-3RV/HA/HB-4RV/HA/HB-5RV/HA/HB-6RV/HA/HB-7

RANGE*RV SERIES100 - 20K100 - 20K100 - 80K100 - 80K

100 - 200K200 - 400K400 - 800K

1K - 2M4K - 8M

RANGE*HA SERIES200 - 40K200 - 40K

200 - 160K200 - 160K200 - 400K400 - 80K

800 - 1.6M2K - 4M

8K - 16M

RANGE*HB SERIES800 - 160K800 - 160K800 - 640K800 - 640K800 - 1.6M1.6K - 3.2M3.2K - 6.4M

8K - 16M32K - 64M

* Based on Standard LV speeds .3 - 60 rpmNote: LV-1 through LV-4 are supplied with LV instruments. LV-2C & LV-3C are optional “cylindrical spindles” o�ering geometry for calculating shear rates. LV and RV/HA/HB spindles are supplied in 302 stainless steel. Optional 316 stainless or te�on coated spindles are available

M = 1 million K = 1 thousand

SPINDLE RANGE*LV-1LV-2LV-3LV-4

LV-5LV-2CLV-3C

15 - 20K50 - 100K

200 - 400K1K - 2M

2K - 4M50 - 100K

200 - 400K

LV-5 is an optional spindle designed to increase measuring range.

LV-1

LV-2

LV-3

LV-4

LV-2C

LV-3C

LV-5

RV/HA/HB-3

RV/HA/HB-4

RV/HA/HB-5

RV/HA/HB-6

RV/HA/HB-7

SPINDLE RACK

RV-1HA/HB-1

RV-2HA/HB-2

Spindles

RV/HA/HB Spindle Set includes spindles #2 - #7 and is supplied with standard Brookfield Viscometers and Rheometers. Spindle #1 is available as an option. Spindle Rack is also available as an option with both LV and RV/HA/HB spindle sets.

Page 40: BEL Catalog 2008

40 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

Note: 1. Wells-Brook�eld cones and cups are calibrated at the factory. Cones ordered after shipment require cups to be returned for calibration to new cone. 2. See page 12 for viscosity ranges

Wells/Brook�eld Spindles & CupsSPINDLECPE-40CPE-41CPE-42CPE-51CPE-52CUPCPE-44YCPE-44PYPCP-3YPCP-6YPCP-4YPCP-7Y

CONERADIUS2.4cm2.4cm2.4cm1.2cm1.2cm

7.50N sec-1

2.00N sec-1

3.84N sec-1

3.84N sec-1

2.00N sec-1

SHEARRATE

.5 mL2.0 mL1.0 mL

.5 mL

.5 mL

SAMPLEVOLUME

.8°3°

1.5°1.5°3°

CONEANGLE

Standard cup without temperature probeStandard cup with RTD temperature probeCup with 1 purge �ttingCup with luer �tting and 1 purge �ttingCup with luer �tting and 2 purge �ttingsCup with luer �tting and 4 purge �ttings

CAP SpindlesSPINDLE

CONERADIUS

SHEARRATE

SAMPLEVOLUME

CONEANGLE

Note: 1. Recommend ordering calibration �uids speci�c to cone for �eld calibration 2. See page 15 for viscosity ranges

CAP-01CAP-02CAP-03CAP-04CAP-05CAP-06CAP-07CAP-08CAP-09CAP-10

13.3N sec-1

13.3N sec-1

13.3N sec-1

3.3N sec-1

3.3N sec-1

3.3N sec-1

2.0N sec-1

2.0N sec-1

2.0N sec-1

5.0N sec-1

67 µL38 µL24 µL

134 µL67 µL30 µL

1700 µL400 µL100 µL170 µL

0.45°0.45°0.45°1.8°1.8°1.8°3.0°3.0°3.0°1.2°

1.511cm1.200cm0.953cm1.200cm0.953cm0.702cm2.399cm1.511cm0.953cm1.511cm

UL Spindles & ChambersSPINDLE

SHEARRATE

SAMPLEVOLUMETYPE

Note: 1. See page 34 for viscosity ranges 2. (E) represents enhanced UL version (introduced Jan. 2006)

N = rpm

YULA-15(E)YULA-15(E)ZULA-31(E)YULA-35(E)YZ

Spindle - 304 stainless steelSpindle - 316 stainless steelSample Chamber - 304 stainless steelSample Chamber - 316 stainless steel

16mL16mL

1.224N1.224N

DIN SpindlesSPINDLE

SHEARRATE

SAMPLEVOLUME

ULA-DIN-85ULA-DIN-86ULA-DIN-87HT-DIN-81 for Thermosel

SC4-DIN-82 for SSA

SC4-DIN-83 for SSA

CHAMBERULA-DIN-6YDAA-1

1.29N1.29N1.29N1.29N1.29N1.29N

17.0 mL6.5 mL2.0 mL7.0 mL1.5 mL1.5 mL

for use with ULA-DIN-86 and 87for use with ULA-DIN-85

CPE-44Y

CPE-40CPE-41CPE-42

CPE-51CPE-52

CABLE SC4-61Y

CAP-XX

YULA-15E

DIN-85

Spindles

Page 41: BEL Catalog 2008

41

*For use with water jacket version only

R/S SpindlesSPINDLECOAXIAL

SAMPLEVOLUME

DGCC48CC45CC25CC14CC8CONERC25-1RC25-2RC50-1RC50-2RC75-1*RC75-2*PLATEPP25PP50PP75*

SHEARRATE

0 - 5039 sec-1

0 - 5143 sec-1

0 - 1290 sec-1

0 - 1290 sec-1

0 - 1290 sec-1

0 - 1290 sec-1

0 - 6000 sec-1

0 - 3000 sec-1

0 - 6000 sec-1

0 - 3000 sec-1

0 - 6000 sec-1

0 - 3000 sec-1

0 - 1309 sec-1

0 - 2618 sec-1

0 - 3926 sec-1

SHEARSTRESS0 - 67 Pa

0 - 206 Pa0 - 195 Pa

0 - 1141 Pa0 - 6502 Pa

0 - 34833 Pa

0 - 12223 Pa0 - 12223 Pa

0 - 1527 Pa0 - 1527 Pa

0 - 452 Pa0 - 452 Pa

0 -16297 Pa0 -2037 Pa0 - 603 Pa

17mL70mL

100mL17mL3mL

0.5mL

.08mL

.15mL

.60mL1.2mL2.0mL3.9mL

1 - 1x103

5 - 3.2x104

20 - 1.5x105

120 - 8x105

670 - 5x106

3.6x103 - 3x107

300 - 1.6x106

500 - 3.2x106

30 - 2x105

60 - 4x105

10 - 6x104

20 - 1.2x105

1500 - 9.9x106

90 - 2x105

20 - 1.2x105

VISCOSITYRANGE (mPa•s)

V80-40V60-30V40-20V30-15V20-10V10-5

806040302010

40302015105

6 - 200 Pa15 - 505 Pa

51 - 1700 Pa120 - 4000 Pa

408 - 13600 Pa3276 - 109200 Pa

VANESPINDLE

VANELENGTH (mm)

VANEDIAMETER (mm)

SHEARSTRESS

Note: See page 31 for spindle ranges

CHAMBER TYPEHT-2HT-2DB-100

Sample Chamber - Reuseable, stainless steelSample Chamber - Disposable, aluminum, 100 units

Thermosel Spindles and ChambersLink hanging con�guration is standard

SPINDLESHEARRATE

SAMPLEVOLUME

*SC4-XXBS = Solid Shaft. Not available for SC4-18 and SC4-21 spindles**Also available as SC4-27D-100 = Disposable spindle, 100 units

SC4-18SC4-31SC4-34SC4-21SC4-27**SC4-28SC4-29HT-DIN-81

1.32N.34N.28N.93N.34N.28N.25N

1.29N

8.0 mL10.0 mL

9.5 mL8.0 mL

10.5 mL11.5 mL13.0 mL

7.0 mL

PVS Spindles and ChambersBOB

SHEARRATE

SAMPLEVOLUME

B1B2B5CHAMBERPVS-30 (standard)Triple Annulus

1.7N0.38N0.85N

23 mL53 mL40 mL

for use with B1, B2 or B5 spindlefor use with PVS - TA5 B5 - D - HC

PVS SPINDLE

PVS CHAMBER

SC4-XXBS SOLID SHAFT*

SC4-XX LINK HANGING

HT-2

HT-2DB-100

CHAMBER RACK HT-54

CC-XX

RCXX-X

V80-40

Spindles

Page 42: BEL Catalog 2008

42 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

KU-2 SpindlesSPINDLEKU1-10KU1-75Y

TYPEStandard Krebs SpindleOptional Paste Spindle

Small Sample Spindles and ChambersSPINDLE

SHEARRATE

SAMPLEVOLUME

SC4-18SC4-31SC4-34SC4-16SC4-25SC4-21SC4-27SC4-15SC4-28SC4-29SC4-14SC4-DIN-82SC4-DIN-83CHAMBER TYPESC4-13RSC4-13RPYSC4-8RSC4-8RPYSC4-7RSC4-7RPYSC4-6RSC4-6RPYSC4-13RD-100

1.32N0.34N0.28N0.29N0.22N0.93N0.34N0.48N0.28N0.25N0.40N1.29N1.29N

6.7 mL9.0 mL9.4 mL4.2 mL

16.1 mL7.1 mL

10.4 mL3.8 mL

11.0 mL13.5 mL

2.1 mL1.5 mL1.5 mL

Note: See page 33 for spindle/chamber ranges**Solid shaft option available for spindles SC4-21 (Part No. SC4-21SD) and SC4-27 (Part No. SC4-27SD).

Sample Chamber w/o temperature probeSample Chamber w/RTD temperature probe & cableSample Chamber w/o temperature probeSample Chamber w/RTD temperature probe & cableSample Chamber w/o temperature probeSample Chamber w/RTD temperature probe & cableSample Chamber w/o temperature probeSample Chamber w/RTD temperature probe & cableSample Chamber - Disposable, aluminum, 100 units

M = 1 million K = 1 thousand

T-Bar Spindles cP(mPa•s)SPINDLET-AT-BT-CT-DT-ET-F

LV156 - 62.5K

312 - 124.8K780 - 312K1.5K - 624K3.9K - 1.5M7.8K - 3.1M

RV2K - 400K4K - 800K10K - 2M20K - 4M

50K - 10M100K - 20M

HA4K - 800K8K - 6M

20K - 4M40K - 8M

100K - 20M200K - 40M

HB16K - 3.2M24K - 6.4M80K - 16M

160K - 32M400K - 80M

800K - 160M

Spiral Adapter SpindleSPINDLESA-70

CHAMBERSA-1Y

Note: See page 38 for ranges

Vane SpindlesSPINDLEV-71V-72V-73V-74V-75

VANELENGTH (in)

2.7081.706.998.463.632

VANEDIAMETER (in)

1.354.853.499.232.316

Note: Container diameter should be twice (2x) the vane diameter when possible. See page 37 for ranges.*When used with an RV Viscometer

T-BAR SPINDLE T-A THRU T-F

CHUCK/WEIGHT/CLOSER ASSEMBLY BTU-18Y

SPIRAL ADAPTER SPINDLE SA-70

PASTE SPINDLE KU1-75Y

KREBS SPINDLE KU1-10

SC4-27SD SOLID SHAFT**

SC4-27 LINK HANGING

CABLE SC4-61Y

SC4-13RPY

SC4-13RD

V-71

Spindles

Page 43: BEL Catalog 2008

43

Type D Extension LinkSPINDLE TYPEYDX-1SP1-UC-YSXV-XX

Male coupling nut; attaches to spindleFemale coupling nut; attaches to viscometerExtension link; see below for lengths

Type S Extension LinkSPINDLEAvailable in LV-4 and RV/HA/HB spindle con�gurations

ExtensionLINKSXV-08SXV-09SXV-24SXV-32SXV-48SXV-80SXV-96

LENGTH1"

1.12"3"4"6"

10"12"

USED WITHUL Adapter

Small Sample AdapterThermosel

Type D/S ExtensionType D/S ExtensionType D/S ExtensionType D/S Extension

Note: Other lengths available; call for details

Quick Connect Coupling (SP-7Y)PARTSP-3SP-4SP-5

coupling to viscometer/rheometercoupling to spindlesleeve (to hold together)

SP1-UC-Y YDX-1

SP1-UC-Y

EXTENSION LINK

MVS-1Y

ABZ

4B2

SP-7Y QUICK CONNECT COUPLING

SP-5

Torque DecalsInstrument CoversKeypad Covers

SP-3SP-4

Specialty Items

4B2 Spindle Required for viscosity testing in accordance with ASTM D2983 (Low Temperature Viscosity Measurement of Automotive Fluid Lubricants)

ABZ SpindleUsed for viscosity testing of thick film pastes. Short spindle length is suitable for immersion into shallow depth containers. Sensing length of spindle is less than 1-inch.

MVS-1Y Flag Impeller Spindle Use with the Small Sample Adapter to help keep sample materials in suspension

Custom Spindles Custom spindles can be developed to meet your particular test requirements. Contact Brookfield or an authorized dealer for details.

Instrument & Keypad Coversavailable for most instruments to protect from spillage, dirt and dust.

Torque Decalsfor standard Brookfield Viscometers/Rheometers to quickly identify the torque range of your instrument.

Page 44: BEL Catalog 2008

44 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

General Purpose Silicone Fluids

5 cps10 cps50 cps100 cps500 cps1000 cps5000 cps12500 cps30000 cps60000 cps100000cps

51050

100500

1,0005,000

12,50030,00060,000

100,000

25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C

Brook�eldPart #

Nominal ViscositycP (mPa•s) Temp °C

High Temperature Silicone FluidsBrook�eldPart #

Nominal ViscositycP (mPa•s) Temp °C Temp °F

HT30000

HT60000

HT100000

30,0009,0004,500

60,00018,0009,000

100,00030,00015,000

25.0°C93.3°C

149.0°C25.0°C93.3°C

149.0°C25.0°C93.3°C

149.0°C

77°F200°F300°F77°F

200°F300°F77°F

200°F300°F

BROOKFIELD ACCESSORIES

Viscosity StandardsBrookfield Viscosity Standards provide a convenient, reliable way to verify the calibration of your Brookfield Laboratory Viscometer/Rheometer. Brookfield Viscosity Standards

are Newtonian, and they are available as either silicone or oil. Silicone fluids are less temperature sensitive than oil fluids. Note: Brookfield recommends that all fluids be replaced annually

Accuracy: ±1% of viscosity value Excellent temperature stability Recommended for use with Brookfield and most other rotational viscometers Most economical Special viscosity values and temperature calibrations available upon request

VisCal KitThe Brookfield VisCal Kit provides all the necessary items to verify calibration of your Viscometer/Rheometer. Includes Brookfield 600mL Beaker, 1 pint of Silicone Viscosity Standard, Dispersing Bottle for cleanup and Trapper Cleaning Agent (available only in USA).

Silicone Viscosity StandardsThese fluids are most commonly used to verify calibration of Brookfield Viscometers/Rheometers.

Special Order Silicone FluidsFor our customers needing a nonstandard viscosity or temperature range, our silicone fluids can be modified to meet most requirements. Viscosity Blends Calibrated at 25°C (77°F)Minimum: 5 cP (mPa•s)Maximum: 60,000 cP (mPa•s)Blends will be within ±2% of requested value Temperature CalibrationsMinimum: 10°C (50°F)Maximum: 80°C (176°F)Minimum temperature increment: 2°C

Page 45: BEL Catalog 2008

45

CAP Viscometer Oil FluidsFor calibrating CAP Series cones each spindle has its own �uid

HOW TO SELECT A CAP FLUID• Determine which viscometer is being used: High Torque or Low Torque.• Determine which temperature model is being used: Low Temperature (5°C-75°C) or High Temperature (50°C-235°C)• Determine which cone is being used.

Brook�eldPart #

Low Temp 25°CHIGH TORQUE CAP LOW TORQUE CAP

High Temp 60°C Low Temp 25°C High Temp 60°C

CAP1LCAP2LCAP3LCAP4LCAP5LCAP6LCAP7LCAP8LCAP9LCAP10L

ConeSpindle

123456789

10

ViscositycP (mPa•s)

89177354708

1,4173,5421,3285,313

21,250236

Brook�eldPart #CAP1HCAP2HCAP3HCAP4HCAP5HCAP6HCAP7HCAP8HCAP9HCAP10H

ViscositycP (mPa•s)

89177354708

1,4173,5421,3285,313

21,250236

Brook�eldPart #CAP0LCAP1LCAP2LCAP3LCAP4LCAP5LCAP1LCAP3LCAP5LCAP2L

ViscositycP (mPa•s)

5789

177354708

1,41789

3541,417177

Brook�eldPart #CAP0HCAP1HCAP2HCAP3HCAP4HCAP5HCAP1HCAP3HCAP5HCAP2H

ViscositycP (mPa•s)

5789

177354708

1,41789

3541,417177

Krebs Viscometer Oil FluidsBrook�eldPart # Temp °C

25.0°C25.0°C25.0°C25.0°C25.0°C

KU64KU79KU84KU95KU106

Nominal ViscosityKrebs Units

64798495

106

General Purpose Oil Fluids

25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C25.0°C

Brook�eldPart #

Nominal ViscositycP (mPa•s) Temp °C

31210750

1,4002,000

11,00020,00080,000

200,000420,000

B31B210B750B1400B2000B11000B20000B80000B200000B420000

R/S Rheometer Oil Fluids

25.0°C25.0°C25.0°C25.0°C25.0°C

Brook�eldPart #

Nominal ViscositycP (mPa•s) Temp °C

41,00011,00041,0004,9004,900

B41000B11000B41000B4900B4900

SpindleC25-1C50-1C50-2C75-1C75-2

Free jar opener with the purchase of two or more viscosity standards.

Oil Viscosity StandardsThese fluids are used for specific instruments using cone/plate or Krebs spindle geometry. Also, certain industries may require use of oil standards.Rheometers.

Accuracy: ±1% of viscosity value Appropriate for use at shear rates greater than 500 sec-1 Recommended for use with cone/plate Viscometers at viscosities above 5,000 cP Recommended for Brookfield CAP series and KU-2 Viscometers and R/S Rheometers Brookfield oil viscosity standards are hydro-carbon based, either mineral oil or polybutenes Note: Other oil fluids are available – call for details Brookfield Viscosity Standards are accurate to ±1% of the stated viscosity and are certified by methods traceable to the United States National Institute of Standards and Technology (NIST). The selection of one or two fluids will normally provide sufficient measurement points to verify calibration of your instrument. All fluids are supplied in 1/2 liter (1 pint) containers complete with a certificate of calibration. CAP Oil Fluids are supplied in 150 mL (4 oz) containers

Page 46: BEL Catalog 2008

46 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

Primary CharacteristicsPARAMETER SENSORIAL DEFINITION INSTRUMENTAL DEFINITION

HARDNESS

SPRINGINESS

ADHESIVENESS

COHESIVENESS

Force required to compress a food between molars. De�ned as force necessary to attain given deformation.Rate at which a deformed material goes back to its undeformed condition after deforming force is removed.

The work necessary to overcome the attractive forces between the surface of the food and the surface of other materials with which the food comes into contact (e.g. tongue, teeth, palate). Work required to pull food away from a surface.The strength of internal bonds making up the body of the product (greater the value the greater the cohesiveness)

Peak force of the �rst compression cycle.

Height that the food recovers during the time that elapses between the end of the �rst bite and the start of the second bite.The negative area for the �rst bite, representing the work necessary to pull compressing probe away from sample.

The ratio of positive force during the second to that of the �rst compression cycle (downward strokes only)

*Parameters utilized in determining the manner in which a food handles and behaves in the mouth. PARAMETERS AS DENOTED WITHIN ORIGINAL SZCZESNIAK et al (1963) AND BOURNE (1978) TPA WORK

Secondary CharacteristicsPARAMETER SENSORIAL DEFINITION INSTRUMENTAL DEFINITION

BRITTLENESS(Fracture force)

GUMMINESS

CHEWINESS

The first significant break in the first compression cycle.

Calculated parameter: Product of Hardness x Cohesiveness

Calculated Parameter: Product of Gumminess x Springiness (essentially primary parameters of Hardness x Cohesiveness x Springiness)

Force at which a material fractures. Related to the primary parameters of hardness and cohesiveness, where brittle materials have low cohesiveness. Not all foods fracture and thus value may relate to hardness if only single peak is present. Brittle foods are never adhesive.Energy required to disintegrate a SEMI-SOLID food product to a state ready for swallowing. Related to foods with low hardness levels.Energy required to chew a SOLID food product to a state where it is ready for swallowing. attribute is di�cult to quantify precisely due to complexities of mastication (shear, compression, tearing and penetration).

BROOKFIELD TEXTURE ANALYZERS

What is texture analysis?Texture analysis is primarily concerned with the evaluation of mechanical characteristics where a material is subjected to a controlled force from which a deformation curve of its response is generated. These mechanical characteristics in food can be further sub-divided into primary and secondary sensory characteristics which have proven to be correlated to sensory perception.

Page 47: BEL Catalog 2008

47

Why measure texture?

Choices forInstrumentationThe chart shows the Brookfield family of Texture Analyzers at a glance. These two instruments are explained in detail on pages 48 – 51.

Price

Performance

Simple compression forQC Applications

LFRA R&D materials tester for compression and tension methods

QTS-25

Consumer products succeed in the marketplace in part because their “textural characteristics” are pleasing to customers. This is certainly true with food products but it also applies to cosmetics, pharmaceuticals, packaging, industrial materials and even adhesive type materials.

Why Choose Brookfield?Brookfield has over 70 years experience in providing reliable, low cost viscosity measuring instruments while offering high quality product support. We are now using this recipe for success to expand our line of physical testing products to include texture analyzers.

Brookfield’s redesign of the LFRA enhances the load capacity and test speeds of the old model, which evolved from the Stevens range of Texture Analyzers and further back to the Boucher Jelly Tester.

The Brookfield Texture Division provides customers with a complete texture assessment service. We specialize in the development of novel and innovative test applications and accessories for solid and semi-solid materials, enabling our customers to maximize the practical value of their texture studies within all test environments.

Utilizing simple compression or tension forces, we are able to imitate almost all conditions imposed during the manufacture or handling of a wide range of foods, industrial materials and personal care products. Such measures provide a “real life” insight into the physical properties of a product, often invaluable in maintaining consistent quality manufacture while minimizing rejects in production.

ApplicationsQuality Control, Product Development and R & D

Ripeness Fracture ForceYield Point ElasticitySpreadability HardnessTackiness Cohesiveness Consistency Burst Strength Relaxation Breaking PointPliability Gel StrengthAdhesiveness Apparent ModulusChewiness Gumminess

Properties Measured

FoodDairy Yogurt Butter CheeseBakery Dough Bread PastrySnack Foods Chips Granola Bars ConfectionsMeat Beef Poultry SeafoodFruit and vegetables

CosmeticsLipstickMascaraPowdercompactsEye liner pencils Creams Soap bars

PharmaceuticalsGelatinsTablet hardnessOintmentAdhesive dressingEye liner pencils

MaterialsPackagingAdhesivesCaulkingRubberGreaseWax

Page 48: BEL Catalog 2008

48 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

Available Load Cells:–100g (1Kg)–1000g (10Kg)–1500g (1.5Kg)–4500g (4.5Kg)

Variety of Test Probes

Variety of Accessories available

Easy-to-Read Display shows key texture data

RS232 Output

Easy-to-Use, Intuitive Controls

Adjustable Test Table for versatility of sample testing

BROOKFIELD TEXTURE ANALYZERS

LFRA Texture Analyzer compression testing for rapid QC analysis

The LFRA Texture Analyzer is the industry standard

instrument for gelatin Bloom assessment (AOAC

Standard Reference). Improved test capabilities

are now incorporated in the New LFRA in conjunction

with an expanded range of test probes and accessories. Enhanced methods include

Texture Profile Analysis for the food industry and

Target Load Analysis for the adhesives market. The LFRA

may be operated stand alone as shown or with

TexturePro Lite software for enhanced capabilities.

Page 49: BEL Catalog 2008

49

Assortmentof Probes

Junior Punch Accessory

Adjustable Vice Jig Small ScaleShear Blade

Load

Ran

ge

Load

Acc

urac

y

Repe

atab

ility

Spee

d Ra

nge

Posit

ion

Rang

e

Setti

ng R

esol

utio

n

Posit

ion

Accur

acy

*Max

imum

Cyc

les

0-4500g0-1500g0-1000g0-100g

0.5%FS0.5%FS0.5%FS0.5%FS

0.1%FS0.1%FS0.1%FS0.1%FS

6-600mm/min6-600mm/min6-600mm/min6-600mm/min

1-75mm1-75mm1-75mm1-75mm

0.1mm0.1mm0.1mm0.1mm

99999999

0.02mm0.02mm0.02mm0.02mm

LFRA4500LFRA1500LFRA1000LFRA100

MODEL

mm = millimeter g = grams FS = Full Scale min = minute *with cycle until reset

What’s Included?Instrument

Choice of Load Cell (installed)

Optional AccessoriesStandard Probe Kit

TexturePro Lite Software

Bloom Sample Bottles & Stoppers

Calibration Weights

Bloom Test Strip

Cylinder Probes

Conical Probes

Spherical Probes

3-Point Bend Fixture (Snap Test)

Adjustable Vice Jig

Back Extrusion Jig

Knife Edges & Wires

Tackiness Testing Jig

Water Baths

TexturePro Lite Software OptionalCollect data in a familiar Microsoft Excel™ environment and easily analyze and store graphical data. Texture parameters such as hardness, cohesiveness, springiness, adhesiveness and chewiness or gumminess are conveniently built into a test results table. Calculation of these parameters are automatically accomplished by use of a check box. A short tutorial will help get you started quickly!

Standard Probe Kit

Bloom Test Strip

The probes and fixtures shown here are just a small selection from our optional accessories. Brookfield can develop custom equipment to meet most any texture measurement application.

Adhesive Tack Tester

Bloom Gel TestAOAC (GMIA) Approved

Snap Test Jig Back Extrusion Cell

Page 50: BEL Catalog 2008

50 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

Weight Set

Available Load Cells:–5Kg–25Kg–50Kg

Status Lights

Stand-Alone Operation Console

Emergency Safety Stop

Analog & RS232 Interface

Rugged and Robust Design

Choose from 54 Probes & 21 Accessory Fixtures available for either compression or tension forces

Accommodates Wide Range of Sample Sizesmaximum vertical travel 520mm

BROOKFIELD TEXTURE ANALYZERS

QTS-25 Texture Analyzer compression and tension testing for comprehensive analysis of mechanical behavior

The QTS-25 is a rugged, self-contained benchtop

instrument providing laboratory precision, even in production environments. It can operate

in stand-alone mode using the dedicated console or with a PC

using TexturePro Software.

Page 51: BEL Catalog 2008

51

Compression Plate

Punch Assembly

3-pt Bend Assembly

Shear Blades

Extrusion Cell Grip Assembly

Friction Assembly

Ottawa Cell

TexturePro Software Optional A convenient one-page test method menu will help you collect data in a familiar Microsoft Excel™ environment and easily store, analyze and graph data. Texture parameters such as hardness, cohesiveness, springiness, adhesiveness and chewiness or gumminess are conveniently built into a test results table. Calculation of these parameters are automatically accomplished by use of a check box. A short tutorial will help get you started quickly!

Load

Ran

ge

Load

Res

olut

ion

Load

Acc

urac

y

Repe

atab

ility

Spee

d Ra

nge

Posit

ion

Rang

e

Posit

ion

Reso

lutio

n

Posit

ion

Accur

acy

Max

imum

Cyc

les

0-25kg0-5kg

1g0.2g

±0.1%FS±0.1%FS

±0.1%FS±0.1%FS

2-1000mm/min2-1000mm/min

100-520mm100-520mm

0.01mm0.01mm

255255

0.02mm0.02mm

QTS-2525QTS-2505

MODEL

mm = millimeter kg = kilogram g = gram FS = Full Scale min = minute

What’s Included?Instrument

Choice of Load Cell (installed)

Controller Console

Position Calibration Rod

Set of three Extension Rods

Optional AccessoriesTexturePro Software

Standard Probe Kit

Standard Base Table

Confectionery Jig

Ottawa Cell

Magness Taylor Probe

3-Point Bend Fixture

FMBRA Dough Pot

Compression Plate

Grip Assembly

Shear Blades

Extrusion Cell

Kramer Shear Cell

Adjustable Vice Jig

Multiple Probe Assembly

Dough & Paste Stickiness

Coefficient of Friction Jig

Calibration Weight

Standard Probe Kit

The probes and fixtures shown here are just a small selection from our optional accessories. Brookfield can develop custom equipment to meet most any texture measurement application.

Page 52: BEL Catalog 2008

52 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

RVDV-II+Pro Viscometer (p6) or RVDV-III Ultra Rheometer (p16) Ball Bearing Suspension (p3)

Small Sample Adapter (p32) SC4-21 SpindleSC4-13RPY Sample Chamber w/RTD probe (p42)

HADV-II+Pro Viscometer (p6) or HADV-III Ultra Rheometer (p16) Ball Bearing Suspension (p3)

TT-200 ProcessViscometer (p64)

TC-102 Water Bath (p29) Small Sample Adapter (p32) SC4-27 Spindle (p42)SC4-13RPY Sample Chamber w/RTD probe (p42)

R/S-CC Plus Rheometer (p22)

TT-100 ProcessViscometer (p62)

TC-112P ProgrammableWater Bath

BROOKFIELD SYSTEMS

The SSB (Starch System Brookfield) is designed to monitor the viscosity of industrial starches during automated quick-cook (gelatinization) and fast cool-down of starch samples. TT-100 Process Viscometer is used for real time starch measurements in paper coatings and adhesives manufacturing. Lab Features & Benefits Fast, reproducible results means production adjustments can be made immediately. Automated, easy-to-compare test results using Optional Software Programmable temperature control +35°C to +95°C Process Features & Benefits Ensures correct viscosity of end product Controls coating thickness during application

Measuring chocolate viscosity is important to the confectioner in order to help optimize chocolate flow properties in a melted condition for various mixing and coating applications. Lab Features & Benefits Determines Casson yield and Plastic Viscosity Conforms to NCA and Bureau of the Technical Committee Office Internationale du Cacao et du Chocolat. Control of melting temperatures assuring reproducible comparisons Easy to clean, easy to operate Process Features & Benefits Provides real time chocolate viscosity measurement and control

Recommended viscometer choices

Chocolate ApplicationsRecommended viscometer choices

SSB: Starch Applications

Page 53: BEL Catalog 2008

53

TT-100 ProcessViscometer (p62)KU-2

Viscometer (p26)

CAP 2000+Viscometer (p14)

AST-100 ProcessViscometer (p60)

RVDV-II+Pro Viscometer (p6) or RVDV-III Ultra Rheometer (p16) Thermosel (p30) SC4-27Spindle (p42)

ProgrammableController (p30)

R/S-CPS Plus Rheometer (p21)

TT-100 ProcessViscometer (p62)

Brookfield has viscometers that have been designed specifically for use in Paint and Coating applications. Whether your requirement is to duplicate results from a Krebs system with the KU-2, simulate behavior at high shear with the CAP, or to measure and control viscosity with the AST-100 or the TT-100 Process Viscometers, we have the solution. Lab Features & Benefits Easy to clean, easy to operate Instant results, no calculations means fewer errors Ensure coating quality Long term reliable performance Economically priced Process Features & Benefits Provides continuous measurement and control Guarantees consistent coating quality Minimize operating costs with less waste

Specific test methods for measuring the viscosity of highway asphalt “binders” at mixing and compacting temperatures using Brookfield’s Thermosel System have been defined by SHRP, the Strategic Highway Research Program, sponsored by the US Government. New methods are also under investigation to ensure consistent asphalt quality during processing using Brookfield’s TT-100 in-line Process Viscometer. Lab Features & Benefits Adheres to ASTM Spec D4402 Ensures asphalt pumpability Provides multiple temperature and shear rate variables for complete viscosity profiles Process Features & Benefits Immediate adjustment of process operations to avoid out-of-spec materials Verify asphalt binder spec without grab samples

Recommended viscometer choices

Asphalt ApplicationsRecommended viscometer choices

Paints, Coatings & Ink Applications

Page 54: BEL Catalog 2008

54 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

R/S-CPS Plus Rheometer (p21)

TT-100 ProcessViscometer (p62)

LFRA Texture Analyzer (p48)

Back Extrusion Cell

BROOKFIELD SYSTEMS

Personal Care Products ApplicationsRecommended instrument choices

Shampoos and lotions need to flow easily yet retain sufficient thickness. Viscosity analysis and temperature profiling are important QC tools to use in confirming the desired behavioral properties. The Brookfield R/S-CPS Rheometer, or any standard Brookfield Rheometer/Viscometer, is important for comprehensive data analysis while the TT-100 Process Viscometer provides in-line viscosity control during processing. Lab Features & Benefits Small sample volume Rapid temperature control with R/S-CPS Process Features & Benefits Correlation with lab data Consistent product quality

The physical consistency of face creams and cosmetic ointments is one of the most important subjective characteristics of these products. Following extrusion principles, the LFRA Texture Analyzer can displace the semi-solid gel of cream or ointment in a controlled manner, revealing the yield and flow characteristics of the product. Texture Features & Benefits Simple, reliable operation for QC or factory environment Real-life measure of sample response Multiple characteristics from a single test

Page 55: BEL Catalog 2008

55

RVDV-I Prime Viscometer (p8) Model D Helipath Stand (p36)

HBDV-II+Pro Viscometer (p6) Spiral Adapter (p38) Ball Bearing Suspension (p3)

R/S-CPS Plus Rheometer (p21)

QTS Texture Analyzer (p50)

Pharmaceutical Applications

Electronics Paste ApplicationsRecommended viscometer choices

Recommended instrument choices

The rheological properties of solder paste affect behavior during application to electronic assemblies. This includes dispensing operations and flow characteristics during screen and stencil printing. The Brookfield RVDV-I Prime Viscometer with Helipath Stand and T-bar spindle provides single point viscosity measurement for QC control. The Brookfield HBDV-II+ Pro Viscometer with Spiral Adapter offers an automated test method for total flow curve evaluation. Lab Features & Benefits Spindle can be inserted directly into paste container Methods comply with IPC test specifications

The physical properties of tablets and capsules are a critical characteristic to both ease of manufacture and product functionality. The hardness of a tablet or the strength of a gel capsule will have an effect on drug release rate in the body. Tests for hardness serve as a QC indicator at the point of packing or filling. The QTS 25 and its associated test accessories can accommodate variable geometries of capsules and tablets while maximizing the value of data obtained from texture investigations. Texture Features & Benefits Multiple applications with single instrument Rapid measurement of physical properties, such as tablet hardness and gelatin strength Stand-alone or PC operation

Most ointments need to be sufficiently thick when standing to prevent them from oozing away from the intended area of use. They also need to flow easily when applied (known as shear thinning behavior). The R/S-CPS Rheometer is the ideal instrument to measure high viscosity at near zero shear rate to determine yield stress values and to create viscosity vs. shear rate flow curves which simulate rubbing and spreading. Lab Features & Benefits Small sample volume Automated test method Rapid temperature equilibration Easily cleaned and maintainable

Page 56: BEL Catalog 2008

56 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

PVS Rheometer (p18)

TT-100 ProcessViscometer (p62)

TT-220 Process Viscometer(p65)

LVDV-II+Pro Viscometer (p6)

Petroleum ApplicationsFor exploration, lab research or drilling/fracturing site fluid monitoring, Brookfield handles your viscosity needs

BROOKFIELD SYSTEMS

PVS Rheometer Fracturing fluids, drilling muds, cements and oil/water emulsions are examples of materials easily analyzed. Compact and portable, the PVS offers the oil and gas industry the most versatile instrument of its kind. Features & Benefits Viscosity measurements under pressure and elevated temperature Automate standard test procedures Easily cleaned and maintained

Recommended viscometer choices

TT-100 & TT-220 Well fracturing operators require in-line viscosity control to ensure the proper rheology of the fracturing fluid being sent down-hole. The TT-100 in-line Viscometers provides real-time measurements of fluids in pressurized lines from storage tanks through blenders before pumping down-hole. The multiple speed TT-220 provides real-time drill mud viscosity data that allows rig operators to obtain yield point and plastic viscosity continuously. Features & Benefits Characterizes drilling fluid viscosity and maintains consistency Eliminates “grab” samples; saves time, provides repeatable measurements

LVDV-II+Pro Viscometer For field engineers at the well site, a simple bench-top Laboratory Viscometer ensures a quick and easy way to check fracturing fluid viscosity before use. The Brookfield LVDV-II+Pro Viscometer with special cylindrical spindles provides coaxial cylinder geometry measurement, simulating appropriate shear rate conditions. Features & Benefits Compact size and versatile for use in the laboratory or field environments Simulates low shear conditions

Page 57: BEL Catalog 2008

57

LFRA Texture

Analyzer (p48)

HBDV-III Ultra CP Rheometer (p16)

RV or HBDV-II+Pro Viscometer (p6)

ProgrammableController (p30)

R/S-SST Plus Rheometer (p23)

RVDV-I Prime Viscometer (p8) Model D Helipath Stand (p36)

Model D Helipath Stand (p36)

LVDV-I Prime Viscometer

(p8)

AST-100 ProcessViscometer (p60)

AST-100FSY ProcessViscometer (p61)

UL Adapter (p34)

Thermosel (p30)

The dairy industry has a broad range of products requiring viscosity and texture measurement, from milk and creams to yogurts and butters. Brookfield offers a selection of instruments to ensure consistent product quality, flow/spread behavior, and mouth-feel. Lab Features & Benefits Accommodates homogenous liquids to mixtures with particles Guarantees customer satisfaction because quality is repeatable Texture Features & Benefits Simple, easy-to-implement test methods Wide choice of probes to simulate customer experience in handling/consumption of product Process Features & Benefits 3A approved designed Real-time process control

Adhesives can vary significantly in viscosity. In-process flow behavior during manufacturing may have lower viscosity values compared to end-point conditions. Final product viscosity can be modest with easy flow capability to paste-like consistency, requiring high force to apply to a substrate. Choosing the proper test method is critical. Lab Features & Benefits Multiple choices for “best-fit” instrument and spindle Guarantees consistent end product from batch-to-batch Small sample size (<2mL) for high value products Process Features & Benefits Continuous control of viscosity when applying to substrate Ensures economic use of adhesives in continuous operations

Recommended instrument choices

Adhesives ApplicationsRecommended instrument choices

Dairy Products Applications

Page 58: BEL Catalog 2008

58 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

RVDV-II+Pro Viscometer (p6) Spiral Adapter (p38)

RVDV-I Prime Viscometer (p8) Model D Helipath Stand (p36)

R/S-SST Plus Rheometer (p23)

LFRA Texture Analyzer (p48)

R/S-SST Plus Rheometer (p23) Vane Spindle (p37)

RVDV-III Ultra Rheometer (p16) Cylindrical Spindle (p39)

BROOKFIELD SYSTEMS

Maintaining consistent food quality and repeatable flow behavior is imperative in the food industry — especially in sauces and dressings. Whether the product will be poured, squeezed from a bottle or used for coating, designing the right test method is key. Lab Features & Benefits Multiple instrument/spindle choices to suit most applications Economically priced to meet low budget requirements Quick, single point viscosity tests often meet the objective Texture Features & Benefits Quick, easy method to quantify flow out of the bottle or tube Rugged, easy-to-use instrument for use on the production floor

The construction industry manufactures a wide range of materials with medium to high viscosity. New methods are available with the introduction of spindle geometries that can handle the mix of product materials ranging from cements, concretes, mortars and grouts to various clay mixtures. Lab Features & Benefits Multiple spindle types can be used with the same instrument minimizing investment cost Yield stress test gives more information than traditional “slump test” Flow curves are quickly generated to show complete shear thinning behavior for consistent quality performance

Recommended instrument choices

Construction MaterialsRecommended viscometer choices

Sauces & Dressings Applications

Page 59: BEL Catalog 2008

59

Questions to Consider1.Whatistheviscosityrangeofyourmaterial?

2.IsyourmaterialNewtonian,Dilatant,Non-Newtonian, ThixotropicorPlastic?

3.Whatistheminimum,maximumandaveragepressure requirementofyourapplication?

4.Whatistheminimum,maximumandaverage temperatureofyourapplication?

5.Whatistheminimum,maximumandaverageflowrate ofyourapplication?

6.Whereinproductionwouldyouliketheviscometer: in-line,onthetopofthetankoronthesideofthetank?

7.Whatelectricalcoderequirementsdoyouhave: NEMA1(generalpurpose—indoor) NEMA4(watertight/dusttightforindoor/outdooruse) NEMA7(explosionproof—Class1,Div.1&2,GroupD) ATEX(explosionproof—Code:EExd11BT6)

Theaboveparametersmayeliminatesomeoftheinstrumentmodelsbecause,forexample,theviscosityishigherthantherangeoftheinstrumentoroutsideofthepressureratingoftheinstrument.Inmanycases,morethanoneinstrumentmaybeapplicable.

Pleaseallowustoassistyouinchoosingthebestviscositycontrolsystemforyourapplication.

AST-100Advancedsensortechnologyfordirectin-lineviscositymeasurement(p60)

TT-100Forin-linesystemapplicationsrequiringpipelinemounting(p62)

TT-200Forin-linesystemapplicationsrequiringflangemounting(p64)

TT-220 ProbeForbothsolventandwaterbasedproducts(p65)

ViscoselForsystemsopentotheatmosphere(p66)

Why Measure Viscosity In-Line?Why Measure Viscosity In-Line?Practicalapplicationofviscositymeasurementdataoftenleadstotheneedforin-processcontrolofviscosity.Theinstallationofviscositycontrolequipmentonaprocesscanprovidealevelofcontrolachievablebynoothermeans.Variationsinviscosityaredetectedandcorrectedinstantlybeforetheycannegativelyaffectproductquality.Realtimeviscositycontrolcanreducedowntimeandmaterialwastebyensuringthattheprocessisoperatingwithinitsspecifiedviscosityparameters.Inmanycases,thesavingsfromincreasedefficiencycanpaybackthecostoftheviscometerinonlyafewmonths.

Why Choose Brookfield?BrookfieldbuildsitsProcessControlViscometerstothesamehighstandardsofperformanceandvalueasitsLaboratoryViscometers.Particularattentionhasbeendevotedtomakingtheseinstrumentsruggedandeasytomaintainforlongserviceindemandingindustrialenvironments.

Page 60: BEL Catalog 2008

60

ProductInlet

Capableofpressuresupto200psi(13.8bar)

andtemperaturesupto250°F(120°C)

Nomovingpartstowear,bindorcontactprocessmaterials

Rugged316SSconstruction

SimpleClean-In-Placedesign

AssemblyGuides

Availableinfoodgradeandexplosion-proofdesigns

ViscositySensor&Chamber

ProductOutlet

Compactdesignforeasyinstallation Savesyoumoney

whileincreasingyourproduction

Availablewithsensorandcontrollerorassensoronly

Continuous,reliable4-20mA,RS232orRS485output

BROOKFIELDPROCESSVISCOMETERS

AST-100 Viscosity Controller Advanced Sensor Technology for simple, direct in-line viscosity measurement

AST-100

T:800.628.8139or508.946.6200F:508.946.6262www.brookfieldengineering.com

Page 61: BEL Catalog 2008

61

VibratingProbe

Sensor

10”

5”

AST-400SYMulti-StationController

12”

5”

AST-300SYSingleStationController

Sensor-only Option: Economicallypriced,sensortransmitterdesignforsimpleequipmentintegration.

Process Viscosity ControllersTheAST-300SYSingleStationViscosityControllerandAST-400SYMulti-StationViscosityControlleraredesignedforusewithBrookfieldAST-100Systemstoaccuratelymeasureandcontrolviscosity.– Precise,programmable,on/offdosingcontrol– Intuitivescreenlayout– Quickselectionofsetupandmenuitems– At-a-glancesetpointandalarmstatus– DisplaysviscosityincP,mPa•s,cStorcup-seconds, currentpHvalueandtemperaturein°Cor°F– ViscosityandpHdatatrending– pHandpumpinterlock– Multi-levelpasswordprotection– Viscosityhigh/lowalarms

AST-300SY Single Station Viscosity ControllerTheAST-300SYSingleStationControllerisdesignedforusewiththeBrookfieldAST-100TSYaspartoftheviscositycontrolsystemtomeasureviscosityandtemperature,interlockwithotherprocessdevices,andaccuratelycontroltheviscosityofyourproductinavarietyofindustrialapplications.

AST-400SY Multi-Station Viscosity ControllerTheAST-400SYMulti-StationControllerisdesignedforusewithuptotenBrookfieldAST-100TSYviscositycontrolunitsaspartofamulti-productviscositycontrolsystem.Thesystemwillmeasureviscosityandtemperature,interlockwithotherprocessdevices,andaccuratelycontroltheviscosityofyourproductsinavarietyofindustrialapplications.

AST-100FSYSanitary Unit

AST-100Compactdesignforeasyinstallation

What’s Available?InstrumentinNema4,Nema7,ATEX,SanitaryorpHControlConfigurations(seepage3foroptionalconfigurations)

Optional AccessoriesSingleStationController

Multi-StationController

MountingBrackets

SolenoidControlValve

ViscosityStandards(p48)

ProtectiveCoversforAST-300SY(p3)

Page 62: BEL Catalog 2008

62

TorqueSensorgives4-20mA

LinearSignal

STT100conformsto3Asanitaryconditionsandhasclean-in-place(CIP)design

Easytocheckandmaintaincalibration

Mountsin-linesupportedbyconnections

Concentriccylinders(Couettetype)providesdefinedshearmeasurement4-20mAoutputsignalprovidesavarietyofdisplayandcontrolcapabilities

Constantspeedorvariablespeedmotor

BROOKFIELDPROCESSVISCOMETERS

STT-100SanitaryUnit

Continuousmeasurementeliminatesneedfor“Grab”

samplingandallowsforpredictionandconstantcontroloffinal

productproperties

Canbeoperatedatshearratesof511sec-1forAmerican

PetroleumInstitute(API)measurementneeds

ShearRates10-1,000sec-1

DefinedshearmeansagreementwithBrookfieldLaboratorymeasurements

atequivalentshearrates

Capableofpressuresupto500psi(34bar)andtemperatures

upto500°F(260°C)

Measurement“Zone”isprotectedfrommainflow,allowingaccurate,repeatablemeasurementundervariableconditions

Availablein1”,1-1/2”,2”or4”pipelineconnections;threadedorflanged,or3”or4”sanitary

T:800.628.8139or508.946.6200F:508.946.6262www.brookfieldengineering.com

TT-100 Viscometer for in-line system applications

Page 63: BEL Catalog 2008

63

What’s Available?InstrumentinNema4,Nema7(explosionproofClassI,Division1&2,GroupDdesign),ATEXorSanitaryConfigurations

Optional AccessoriesOptional12Vor24VDCoperation

ReadoutIndicator

VariableSpeedMotor

TT-100Standardinstrumentforgeneralservice

TT-100VSOptionalvariablespeedinstrumentformultipleshearrates

Page 64: BEL Catalog 2008

64 T:800.628.8139or508.946.6200F:508.946.6262www.brookfieldengineering.com

Continuousmeasurementeliminatesneedfor“Grab”

samplingandallowsforpredictionandconstantcontroloffinal

productproperties

Flangemountabledirectlyintotankorinpipelinetee

Canbeoperatedatshearratesof511sec-1forAmerican

PetroleumInstitute(API)measurementneeds

Synchronousorvariablespeed

drivemotor

Concentriccylindersprovidedefinedshearmeasurement4-20mAoutputsignalprovidesavarietyofdisplayandcontrolcapabilities

Rugged300SSconstruction

Signaltransducerhousing

Flushingfittingoptional

Mountingflange

ShearRates10-1,000sec-1

Repeatableto±.5%ofspan

DefinedshearmeansagreementwithBrookfield

Laboratorymeasurementsatequivalentshearrates

Capableofpressuresupto500psi(34bar)andtemperatures

upto500°F(260°C)

BROOKFIELDPROCESSVISCOMETERS

What’s Available?InstrumentinNema4orNema7(explosionproofClassI,Division1&2,GroupDdesign)Configurations

Optional AccessoriesOptional12Vor24VDCoperation

ReadoutIndicator

VariableSpeedMotor

TT-200 Viscometer for in-line system applications

Page 65: BEL Catalog 2008

65

ConcentricCylindersprovidedefinedshearmeasurement

Lightenoughtobehandheld

Modularforeasyremoval

orinsertion

Adjustablesupportforimmersiondepth

Mountsinopentankorcontainer

Helpsreduceproductionandoperatingcosts

Optional3-speedmotordrive

Continuous,quick,linearresponse

Definedshearmeasurement

Continuouslinear4-20mAoutput

Minimumoperatorinvolvementrequiredforstart-up

Operatesat-40°Cto100°C

Optimizesproductqualitythrough

automaticcontrol

Providespermanentrecordofproductionhistory

Optionalcontrollerprovidesviscosityset-point,

monitorandcontrol

11”,17”,24”,30”and38”probelengthsavailable

TT-220 Probe Viscometer for direct in-tank measurement

What’s Available?InstrumentinNema4orNema7(explosionproofClassI,Division1&2,GroupDdesign)Configurations

Optional AccessoriesReadoutIndicator/Controller

Page 66: BEL Catalog 2008

66 T:800.628.8139or508.946.6200F:508.946.6262www.brookfieldengineering.com

NEWVTE-250 Viscometer

ViscosityRange:10-10,000cP

(mPa•s)

QuickConnectFittings

Universalmountingbracket

In-lineautomaticviscositycontrol

Outputsignal4-20mA

SelectablereadoutdirectlyincPorunitsofchoice

(cupsecondsorotherengineeringunits)

Simpletoinstall,startup,operate

andclean

SampleChamber–Durableand easilycleaned–Availablein plasticor stainlesssteel

Economicallypriced

Easyviscosityrangechangecanbemadewithoutspecial

toolsorrecalibration

Automaticallyoperateswith90-264VAC,47-63Hz

20wattspowersupply

Built-incontrolfeature:(upto3ampsolenoidrelay)

DigitalDisplay

NewEasytoUseControls

BROOKFIELDPROCESSVISCOMETERS

What’s Available?VTE-250In-LineViscometer

Optional AccessoriesSamplechambers,plasticorstainlesssteel(p68)

SolenoidControlValve(p68)

SolventBottle(p68)

TestStand,stationaryorwithwheels(p68)

MountingBrackets(p68)

AdditionalSpindles

ViscosityStandards(p68)

ProtectiveKeypadCovers(p3)

Viscosel Series for systems open to the atmosphere

Page 67: BEL Catalog 2008

67

VTA-120 Viscometer Solventvalve

gauge

Built-inviscosityindicator

Optionalcup-seconds

indicator

Built-In,easily-readsetpoint

indicator/controller

Solventorwateradditionmadedirectlyintothesamplechamberthroughbuilt-invalve

Completein-lineautomaticviscositycontrolsystem

Simpletoinstall,startup,operate

andclean

Easy-to-readIndicator–Responsive–Continuous sensing

Outputsignalwithpneumaticindicator3-15psi(.20-1bar)or4-20mAwithconverter,0-15psi(0-1bar)tosolventvalve

Easyviscosityrangechangecanbemadewithouttools

orrecalibration

Noelectricalcomponentssafeforsolventenvironments

Operateson20-22PSIG(1.4-1.5bar)airinputwith3.5CFMmaximumconsumption

ViscosityRange:1-4,000cP

(mPa•s)

SampleChamberavailableinplasticor

stainlesssteel

What’s Available?VTA-120In-LineViscometer

Optional AccessoriesSamplechambers,plasticorstainlesssteel(p68)

SolenoidControlValve(p68)

SolventBottle(p68)

TestStand,stationaryorwithwheels(p68)

MountingBrackets(p68)

AdditionalSpindles

ViscosityStandards(p68)

Page 68: BEL Catalog 2008

68 T:800.628.8139or508.946.6200F:508.946.6262www.brookfieldengineering.com

VTA106-212AYSolventLineAssembly

VTA106-104AYAirSetAssembly

VTA107-2SupportBracket

SB-248”Column

SB-3YBase

SB-9YPortableBase

VTA107-44SInletQuickConnect

SCV-1HYSolventControl

Valve

TT-100-2894-20mAInput

SignalIndicator

UsedwithViscoselSeries

Viscometers

VTA107-45Outlet

QuickConnect

UsedwithProbeSeriesViscometers

UsedwithTT-100Series

Viscometers

SB-23YPipeStandAssembly

VTA107-36TSampleChamber

VTA107-33TSampleChamber

VTA106-155YSolenoidValve

Assembly

VTA107-44InletQuick

Connect

SB-10YSolventBottle

SB-1YSolventBottle

Holder

BROOKFIELDPROCESSVISCOMETERS

Page 69: BEL Catalog 2008

69

Testing & Consulting

Brookfield’s state-of-the-art laboratory offers a variety of viscosity testing services capable of measuring Newtonian and non-Newtonian fluids using a wide range of spindle geometries. Detailed test results include equipment and measurement system description, viscosity data which includes appropriate tables and graphs, and any recommendations pertinent to your specific material and associated method.

Viscosity Testing Services Available Test and RecommendA simple evaluation designed to help determine the appropriate Brookfield equipment for your application. Fluid ProfilingAnalysis testing to determine properties of your fluid sample. We will supply a complete report on the characteristics of your sample. Dispute ResolutionAnalysis testing for mediating a resolution between producers and/or suppliers obtaining varying viscosity results of the same material. Multiple Sample TestExpands the capability of your laboratory by utilizing Brookfield’s services to accomplish testing work on a timely basis. Viscosity Test Services are performed for a fee with the exception of “Test and Recommend”. For more information, contact our Rheology Laboratory:Tel: 800.628.8139 or 508.946.6200, ext. 144Fax: 508.946.6262E-mail: [email protected]

Methodology Consulting Service On Viscosity Test Development* A detailed report will include: –Sample preparation method –Equipment recommendations –Controlled shear rate and shear stress tests –Temperature profiling –Thixotropic testing –Material structure recovery evaluation –Data collection and reporting –QC viscosity control limit values For more information, contact our Consulting Services Department:Tel: 800.628.8139 or 508.946.6200, ext. 143Fax: 508.946.6262E-mail: [email protected] *Note: Consulting Services can also be scheduled to take place at Brookfield’s facility in Middleboro, MA

The key to successful quality control is designing effective viscosity test methods. Our Methodology Consulting Service brings a Brookfield consulting engineer to your facility to review and recommend appropriate test methods for your materials. We will work with you to define acceptable viscosity behavior taking into consideration relevant shear rates, shear stresses, temperature and time sensitivity issues.

Page 70: BEL Catalog 2008

70 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

For your viscometers and rheometers, we will inspect your instrument for wear, clean, adjust and lubricate the internal mechanisms, replace part of the sensing system element (the pivot

support assembly and, when required, the pointer shaft), and check your spindles. Spindles that are returned to a Brookfield Service Center are also straightened if necessary. In addition to this maintenance, we calibrate and certify in writing that your instrument is operating within proper Brookfield specifications. This certification states that your instrument has been calibrated against standards which are traceable to the National Institute of Standards & Technology (NIST). This is becoming an increasingly important requirement as industry throughout the world takes steps to comply with ISO 9000 regulations.

For texture analyzers, we also inspect for wear, clean, adjust and lubricate internal mechanisms, and adjust, if necessary, the zero and span for proper load cell performance. Certified calibration weights can be purchased for your texture analyzer.

…for long life and optimal performance of your Viscometer, Rheometer and Texture Analyzer

Calibration & Certification

ViscosityStandards

Fluids shouldbe replaced

annuallySee pages 44 & 45

for details.

Brookfield Service CenterCalibration and Certification Brookfield Engineering recommends that you return your instrument to Brookfield or an authorized dealer on an annual basis for our Calibration and Certification Service. Please call for a Return Authorization Number. Special Arrangements:Loan instruments are available should you need a temporary replacement while your instrument is in for service. Contact Brookfield or an authorized dealer. Twenty-Four and 48 hour rush service can be arranged. Call for details. Ball Bearing Retrofit for RV/HA/HB torque range on DV-I Prime, DV-II+ or Pro and DV-III+ or Ultra Contact the Customer Service Department for complete details:T: 800.628.8139 or 508.946.6200 E-mail: [email protected] Outside the United States, contact our authorized representatives. See Pages 73-75 for a comprehensive list.

Brookfield On-Site Service Calibration and Certification* We now offer On-Site Calibration and Certification Service. Ideal for multiple instrument users, this service allows all your instruments to be serviced at your facility by our trained technician in one convenient visit. Benefits include: –Minimal production disruption –Reduced down time –No shipping damage or costs –Expert on-site advice in preventative maintenance For more information, contact our Field Service Specialists:T: 800.628.8139 or 508.946.6200 E-mail: [email protected] *Note: Spindle straightening not performed on-site. Spindles mustbe shipped to Brookfield Engineering in Middleboro, MA

IQ, OQ, PQ for Brookfield Products For those customers in specific industries who need documented validation of installed instrument systems we offer a number of approaches. Call for details or go to www.brookfieldengineering.com.

Ball Bearing Suspension A more durable ball bearing suspension system is available as an option for new viscometers and rheometers as well as a retrofit on your current instrument! This suspension replaces the traditional pivot point and jewel system and is designed for use in busy work areas where instruments experience exceptionally heavy use and/or have multiple operators. This retrofit is available for DV-I Prime, DV-II+Pro Viscometers, or DV-III Ultra Rheometers, including Cone/Plate versions, in the torque ranges of RV, HA, and HB.

Page 71: BEL Catalog 2008

71

Education

Practical Course on Viscosity Measurements A single-day course designed to address the major concerns about Brookfield rotational viscosity measurements. At this course, you will learn: – Principle of Operation: How the viscometer makes measurements – Calibration: The truth about calibration checks – Rheology: Why fluids change their flow behavior and why you need to understand it – Methodology: How to write a method everyone can live with — and use – Data Interpretation: What all the viscosity data really means Two options for attendance are offered: Option #1: At Brookfield, Middleboro, MA – Provides hands-on lab time, small class size and the opportunity to test your sample Option #2: At major metropolitan areas – Regionally located for convenience – Limited hands-on time with your fluid

Advanced Course on Rheology Test Methods A single day course designed to use real sample testing data to determine best methodology. At this course you will address: – Flow behaviors and how to characterize method development – Controlled stress vs. controlled rate measurements – Measuring yield stress, creep and recovery of product structure after flow – Math modeling for advanced data analysis – Measuring viscosity on-line in your process

This course is being offered once per calendar quarter and only at Brookfield in Middleboro MA. Includes hands-on lab time working with your sample to develop best practice test methodology.

Practical Course on Texture Analysis A single-day course designed to provide a better understanding of texture analysis as well as the practical use of Brookfield Texture Analyzers. This course addresses: – Principles of texture analysis – Considerations for successful instrumental measurements – An overview of accessories and their applications – Proper texture testing measurements – Developing test method

Who are the instructors? Experienced presenters from the technical staff of Brookfield Engineering Laboratories lead each seminar.

What else? Customers are encouraged to bring samples of their material for discussion with prior approval. Course Attendees will receive a course workbook and Brookfield Training Certificate for their training records. Note: Classes can be presented at the customer’s site. Please ask for information regarding this option. For more information on the schedules or to register for a course, contact the Customer Training Department at Brookfield:Tel: 800.628.8139 or 508.946.6200Fax: 508.946.6262E-mail: [email protected]

Page 72: BEL Catalog 2008

72 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

GlossaryViscosity Glossary3Aa US industrial standard for process equipment design; required certification for clean-in-place capability.

Absolute Viscositythe viscosity value associated with aNewtonian material

ASTMAmerican Society of Testing and Materials

Autorangemaximum viscosity value that can be measured using a specific spindle at a designed rpm.

bobspindle used with PVS Rheometer;also referred to as “bob/stator” because it does not rotate on this instrument. The sample cup rotates instead, causing the shearing action.

Concentric Cylindera cylinder within a cylinder. For viscosity measurement, a cylindrical spindle rotates within a cylindrical chamber. Also known as “Coaxial Cylinder” because both cylindershave the same center line.

DINDeutsche Industrie Normung, Germanorganization responsible for establishing test standards; similar to ASTM in United States.

dyne•cma unit of measurement for torque.

Footprintthe bench space or area required for an item of equipment.

Gapthe distance between the spindle and the chamber or cup in which the spindle is rotating.

Guard Legthe protective bracket for spindles supplied with standard Brookfield LV and RVViscometers/Rheometers.

In-lineprocess viscometer placement in a pipe.

NISTNational Institute of Standards and Technology. US Government organization for test standards.

Newtoniana material whose viscosity value is the same at all shear rates.

Non-Newtoniana material whose viscosity changes as shear rate changes.

On-lineuse of a process viscometer to provide continuous viscosity measurement of a material.

Pneumaticair operated

PPplate and plate geometry.

Relative Viscositythe viscosity value of a non-Newtonianmaterial at a defined shear rate.

RPMrotations per minute; a unit of measurement for spindle speed.

RTDresistance thermal detector; type of sensorfor measuring temperature

sec-1

the scientific unit of measurement for shear rate; expressed as “reciprocal seconds” or “inverse seconds.”

Shear Ratethe velocity gradient in a flowing material; the shape and rotational speed of the spindle rotating in a chamber or cup are used to calculate shear rate.

Shear Stressthe force per unit area used to move a material.

Spindle Geometrythe shape of a spindle. Brookfield spindles supplied with standard Viscometers/Rheometers (Dial Reading, DV-E, DV-I Prime, DV-II+Pro, DV-III+) are disc type. Other choices include Cylindrical, Cone, Plate, KREBS, etc.

Torque Rangethe torque measurement capability of a Brookfield Viscometer/Rheometer measured in dyneocm;designations such as LV, RV, HA or HB are used to define the Torque Range for a specific instrument.

Torque %the amount of torque resistance measured by a rotating spindle immersed in a material.

Yield Stressthe amount of force required to cause amaterial to flow.

Texture Analysis GlossaryCompression Testingthe sample is “compressed” with a probe of greater surface area to that of the sample.

Deformation the change in height of a sample whena force is applied.

Extrusion Testingthe sample is compressed until flow commences through an outlet. Texture analysis utilizes both forward (forced through an aperture) and backward extrusion (forced back around the compressing probe).

Penetration Testingthe sample is “penetrated” with a probe of smaller surface area than that of the sample. This creates both shear and compression forces within the sample and provides a good indication of product hardness and consistency.

Shear Testingblades or wires are utilized to cut through the sample and evaluate cross-sectioned characteristics using a combination of compression, shear and tearing forces dependant upon the geometry of the cutting fixture.

Snap Testingused to assess the fracture and bendcharacteristics of solid materials supportedat either end and compressed in its center.

Stress Relaxationsample is compressed to a target distance and held for a period of time. The sample relaxes under constant stress and the rate and degree of relaxation is used to evaluate sample elasticity, freshness, etc.

Tension Testingthe sample is fixed to both the base and the traveling beam of the texture analyzer and “stretched” via an upward movement.

Conversion TablesViscosity 1 cP = 1 mPa•s 1 P = 100 cP 1 Pa•s = 1,000 mPa•s

Sample Volume 1 L = 1000 mL 1 mL = 1000 µL 1 gal = 8 pt. = 3.7 L 1 pt = 16 oz.

Torque Range LV = 673.7 dyne•cm RV = 7,187 dyne•cm HA = 14,374 dyne•cm HB = 57,496 dyne•cm 5xHB = 287,480 dyne•cm 1N•m = 107 dyne•cm

Temperature °C = 5 (°F-32) _ 9

Texture 1 Kg = 1000 g 1 Kg = 9.8 N 1 inch = 2.54 cm 1 cm = 10 mm

Please refer to Brookfield’s publication“More Solutions to Sticky Problems” for a detailed explanation of viscosity and Brookfield methodology for making measurements.

Page 73: BEL Catalog 2008

73

Brookfield DealersDOMESTIC DEALERSL = Laboratory P = Process

ALABAMATOTAL EQUIPMENT, INC. – LBrewton, AL 36426Tel: (251) 809-3076E-mail: [email protected]

ARIZONAPHOENIX INSTRUMENTATION, INC. – L,PPhoenix, AZ 85021Tel: (602) 393-3045E-mail: [email protected]: www.phoenixinstrumentation.com

CALIFORNIACFM-SF, INC. – L,PMartinez, CA 94553Tel: (925) 370-1500E-mail: [email protected]: www.cfmcontrols.com

GOLDEN STATE CONTROLS – PIrvine, CA 92618Tel: (949) 559-1941E-mail: [email protected]: www.iwestco.com

PACIFIC PROCESS INC. – LNewhall, CA 91322Tel: (661) 424-1690E-mail: [email protected]

COLORADOCFM - PROCESS CONTROLS LLC – PLakewood, CO 80214-2403Tel: (303) 232-4996E-mail: [email protected]

ROCKY MOUNTAIN SCIENTIFIC SOLUTIONS – LColorado Springs, CO 80921Tel: (719) 484-0045E-mail: [email protected]

FLORIDAHILE CONTROLS OF FLORIDA, INC. – PWinter Springs, FL 32708Tel: (407) 327-8000E-mail: [email protected]: www.hilecontrols.com

PAUL N. GARDNER COMPANY – LPompano Beach, FL 33060Tel: (954) 946-9454 (800) 762-2478E-mail: [email protected]: www.gardco.com

GEORGIAHORTON INSTRUMENT CO., INC. – PAtlanta, GA 30305Tel: (404) 231-3131E-mail: [email protected]

IDAHOFIELD INSTRUMENTS & CONTROLS – PBoise, ID 83709Tel: (208) 867-2276E-mail: [email protected]

ILLINOISBROOKFIELD ENGINEERING LABS. – L,PMt. Prospect, IL 60056Tel: (847) 368-8472E-mail: [email protected]

LOUISIANAPETRO-CHEM EQUIPMENT CO. – PBaton Rouge, LA 70816Tel: (225) 292-8400E-mail: [email protected]: www.petrochemequipment.com

MARYLANDBYK-GARDNER USA – LColumbia, MD 21046-2729Tel: (800) 343-7721 (301) 483-6500E-mail: [email protected]: www.bykgardner.com

MASSACHUSETTSPROCESS EQUIPMENT &TECHNOLOGIES, INC. – L,PHanover, MA 02339Tel: (781) 871-5843E-mail: [email protected]

MICHIGANADVANCE AUTOMATED SYSTEMS, INC. – PSparta, MI 49345Tel: (616) 887-0316E-mail: [email protected]: advanceautomatedsystems.com

MINNESOTACOMBUSTION & CONTROLENGINEERING, INC. – L,PMaplewood, MN 55117Tel: (651) 488-5518E-mail: [email protected]: www.combustionandcontroleng.com

MISSOURIECC SUPPLY COMPANY – L,PSt. Louis, MO 63144Tel: (314) 645-2420E-mail: [email protected]: www.eccstl.com

NEW MEXICOPHOENIX INSTRUMENTATION, INC. – PAlbuquerque, NM 87107Tel: (480) 991-1440E-mail: [email protected]: www.phoenixinstrumentation.com

NORTH CAROLINAW.K. HILE COMPANY, INC. – L,PMatthews, NC 28106-1015Tel: (704) 847-9125E-mail: [email protected]: www.wkhile.com

OHIOFOX & DOLE TECHNICAL SALES, INC. – L,PCleveland, OH 44146Tel: (440) 735-0100E-mail: [email protected]: www.foxanddole.com

W.T. BRYAN & ASSOCIATES, INC. – L,PCincinnati, OH 45231Tel: (513) 522-8532E-mail: [email protected]: www.wtbryan.com

PENNSYVANIAJ.M. WALTERS COMPANY – L,PPottstown, PA 19464Tel: (610) 970-7911E-mail: [email protected]: www.jmwalters.com

FOX & DOLE TECH. SALES, INC. – L,PBridgeville, PA 15017-0256Tel: (412) 257-0200E-mail: [email protected]: www.foxanddole.com

TENNESSEEP.O. DES MARAIS CO. – PNorris, TN 37828Tel: (865) 494-9368E-mail: [email protected]: www.podtn.com

TEXASJD INSTRUMENTS, INC. – L,PHouston, TX 77224-9463Tel: (713) 468-8087E-mail:[email protected]: www.jdinstruments.com

UTAHMOUNTAIN STATES INSTRUMENTS – PSalt Lake City, UT 84120Tel: (801) 521-8045E-mail: [email protected]: www.iwestco.com

WASHINGTONFIELD INSTRUMENTS & CONTROLS – PSpokane, WA 99218Tel: (509) 466-8226E-mail: [email protected]: www.fieldinst.com

EXPORT DEALERSL = Laboratory P = Process

ALGERIA, MOROCCO, TUNISIAELCOMETER SA – LB 4681 Hermalle sous Argenteau, BelgiumTel: (32) 4/379-9610E-mail: [email protected]: www.elcometer.be

ARGENTINABIO ANALÍTICA ARGENTINA S. A. – LBuenos Aires, ArgentinaTel: (54) 11/4515-0117E-mail: [email protected]: www.bioanalitica.com.ar

pH. ELECTRONICA S.A. – PCapital Federal BS AS, ArgentinaTel: (54) 11/4331-0707 E-mail: [email protected]: www.phelectronica.com.ar

AUSTRALIABIOLAB (AUST.) PTY LTD – LBraeside, VIC, AustraliaTel: (61) 1300/736767E-mail: [email protected]: www.davidson.com.au

DAVIDSON MEASUREMENT (DIV. OF BIOLAB) - PBraeside, VIC, 3195 AustraliaTel: (61) 1300 SENSOR (736-767)E-mail: [email protected]: www.davidson.com.au

AUSTRIAINULA GmbH – L1082 Vienna, AustriaTel: (43) 1/405-6235E-mail: [email protected]: www.inula.at

BELGIUMANALIS N.V. – L9000 Gent, BelgiumTel: (32) 9/243-7710E-mail: [email protected]: www.analis.com

ELSCOLAB NV – L, P9150 Kruibeke, BelgiumTel: (32) 3/250-1570E-mail: [email protected]: www.elscolab.com

BRAZILALEM MAR COMERCIAL E INDUSTRIAL S.A. – L01026-000 São Paulo, SP, BrazilTel: (55) 11/3229-8344E-mail: [email protected] / [email protected]: www.alemmar.com.br

BRASEQ BRASILEIRA DEEQUIPAMENTOS LTDA. – L, PJarinu, SP, 13240-000, BrazilTel: (55) 11/4016-1313E-mail: [email protected]: www.braseq.com.br

BULGARIA/MACEDONIAMARVEL LTD. – L4004 Plovdiv, BulgariaTel: (359) 32/678026E-mail: [email protected]: www.marvel.bg

CANADACAN-AM INSTRUMENTS LTD. – L,POakville, Ontario L6H 6C9, CanadaTel: 905-829-0030E-mail: [email protected]: www.can-am.net

CANADA - Alberta onlyJD INSTRUMENTS, INC. – PHouston, Texas 77224-9463Tel: (713) 468-8087E-mail: [email protected]: www.jdinstruments.com

CANADA – Quebec & Maritime PROVAN CONTROLES – PSt. Laurent, Quebec H4S 1S3, CanadaTel: (514) 332-3230E-mail: [email protected]: www.provan.ca

CHILEARQUIMED S.A. – L,PSantiago, ChileTel: (56) 2/634-6266E-mail: [email protected]: www.arquimed.cl

CHINA (P.R.)CHE SCIENTIFIC CO. (HONG KONG) LTD. – LHong Kong, P.R. ChinaTel: (852) 2481-1323E-mail: [email protected]: www.chescientific.com

CHELLESON SCIENTIFIC INSTRUMENTS COMPANY - LHong Kong, P.R. ChinaTel: (852) 2413-6700E-mail: [email protected]: www.chelleson.com

Page 74: BEL Catalog 2008

74 T: 800.628.8139 or 508.946.6200 F: 508.946.6262 www.brookfieldengineering.com

PRECISA INTERNATIONAL (SHANGHAI) CO., LTD. - LShanghai, 200030, P.R. ChinaTel: (86) 021/6448-3377E-mail: [email protected] / [email protected]

SHANGHAI RENHE SCIENTIFIC INSTRUMENT CO., LTD. - LShanghai 200070, P.R. ChinaTel: (86) 21-5670-2010E-mail: [email protected]: www.renhe.net

SHANGHAI YINKE TECHNOLOGY CO., LTD. - PShanghai, P.R. ChinaTel: (86) 21-62433309E-mail: [email protected]

SHANXI TIANMEI SCIENTIFIC INSTRUMENT CO., LTD. - LXi’an Hi-Tech Ind Dev Zone, 710075, P.R. ChinaTel: (86) 29-87999888E-mail: [email protected] / [email protected]

SINOINSTRUMENT CO., LTD. - LGuangzhou 510610, P.R. ChinaTel: (86) 020/8351-0088E-mail: [email protected]: www.sinoinstrument.com

STOWELL COMPANY - PBeijing 100021, P.R. ChinaTel: (86) 010-87730218E-mail: [email protected]

TIANJIN DIAMOND INDUSTRY & TRADE CO. LTD. - LTianjin, 300074, P.R. ChinaTel: (86) 022/2332-7102 / 2332-7079E-mail: [email protected]: www.bf17.com

COLOMBIABIOLABOR S.A. – L,PBogota, ColombiaTel: (57) 1/260-0401E-mail: [email protected]: www.biolabor.net

COSTA RICAANALYTICAL INSTRUMENTS, S.A. – LSan Jose, Costa RicaTel: (506) 272-4700E-mail: [email protected]: www.ai.co.cr

CZECH REPUBLIC/UKRAINE/BELARUSSYNPO A.S. – L,PPardubice Czech RepublicTel: (420) 46/606-7293E-mail: [email protected]: www.synpo.cz

DENMARKBlumLab – P4850 Stubbekøbing, DenmarkTel: (45) 55/312009E-mail: [email protected]: www.blumlab.com

VWR/BIE & BERNTSEN – LDK-2370 Herlev, DenmarkTel: (45) 4386-8788E-Mail: [email protected]: www.vwr.com

EGYPTCTS CHEMICAL & TECHNICAL SERVICES – L,PCairo, EgyptTel: (20) 2/2378-2908 / 2378-4973E-mail: [email protected]

ESTONIA/LATVIA/LITHUANIAG. W. BERG OÜ – L12915 Tallinn, EstoniaTel: (372) 6/505658E-mail: [email protected]: www.gwb.ee

FINLANDOY G.W. BERG & CO. AB – L, PFIN-01511 Vantaa, FinlandTel: (358) 201/255255E-mail: [email protected]: www.gwb.fi

FRANCEEQUIPEMENTS SCIENTIFIQUES – P92380 Garches, FranceTel: (33) 1/479-59990E-mail: [email protected]: www.es-france.com

LABOMAT ESSOR – L93287 Saint-Denis Cedex, FranceTel: (33) 1/4809-6611E-mail: [email protected]: www.labomat.com

VWR INTERNATIONAL S.A.S. – LF94126 Fontenay-sous-Bois, FranceTel: (33) 1/4514-8500E-mail: [email protected] Website: www.fr.vwr.com

GERMANYBROOKFIELD ENGINEERING LABS.VERTRIEBS GmbH – L,PD-73547 Lorch, GermanyTel: (49) 7172/927100E-mail: [email protected]: www.brookfield-gmbh.de

VWR INTERNATIONAL GmbH – L64295 Darmstadt, GermanyTel: (49) 6151/3972-152E-mail: [email protected]: www.vwr.com

GREECEP. BACACOS S.A. – L10438 Athens, GreeceTel: (30) 210/523-1271E-mail: [email protected]: www.bacacos.gr

HONG KONGCHE SCIENTIFIC CO. (HONG KONG) LTD. – L58-66 Tai Lin Pai RoadKwai Chung, N.T. , Hong Kong, P.R. ChinaTel: (852) 2481-1323E-mail: [email protected]: www.chescientific.com

HUNGARYSZIKKTI LABOR LTD. – L, P1034 Budapest, HungaryTel: (36) 1/388-8752E-mail: [email protected]: www.szikktilaborkft.hu

ICELANDGROCO ehf – L105 Reykjavik, IcelandTel: (354) 568-8533E-mail: [email protected]: www.groco.is

INDIAM/S. M. J. CORPORATION – LMumbai, 400 021, IndiaTel: (91) 22/2578-5712E-mail: [email protected]: www.cabhay.co.in

SUNJAY BIOTECH SOLUTIONS PVT. LTD. – L,PMumbai, 400 031, IndiaTel: (91) 22/2417-1475E-mail: [email protected]: www.anmalliance.com

INDONESIAPT. TRANSINDOTAMA SINAR PERKASA – L,PJakarta 14240, IndonesiaTel: (62) 21/45840670-72/45845756/45845758E-mail: [email protected] /[email protected]: www.transindotama.com

IRELANDFANNIN LTD – LDublin 18, IrelandTel: (353) 1/290-7000E-mail: [email protected]: www.fannin.ie

FULLBROOK SYSTEM LIMITED – PHerts HP1 2UJ, EnglandTel: (353) 1-442-876777E-mail: [email protected]: www.fullbrook.com

ISRAELAGENTEK (1987) LTD. – L, PTel-Aviv, 61580, IsraelTel: (972) 3/649-3111E-mail: [email protected]: www.agentek.co.il

ITALYGENERALCONTROL S.P.A. – P20151 Milano, ItalyTel: (39) 02/3801-1111E-mail: [email protected]: www.generalcontrol.it

URAI SPA – L20090 ASSAGO (Milano), ItalyTel: (39) 02/892-3991E-mail: [email protected]: www.urai.it

JAPANJAPAN MACHINERY COMPANY – PChuo-Ku, Tokyo 104-0061 JapanTel: (81) 3/3573-5421E-mail: [email protected]

NIPPON S.T. JOHNSON SALES CO., LTD. – LTokyo, JapanTel: (81) 3/5210-5211E-mail: [email protected]: www.njc-net.co.jp

KOREAHWASHIN INSTRUMENT CO., LTD. – L,PSeoul, KoreaTel: (82) 2/3450-5605E-mail: [email protected]: www.hwashin.net

MALAYSIAMECOMB MALAYSIA SDN. BHD. – LSelangor, MalaysiaTel: (60) 3/7874-3422E-mail: [email protected]: www.mecomb.com

PRECISION CONTROL SDN BHD – PSelangor, MalaysiaTel: (60) 3-5191-8113E-mail: [email protected]: www.precisioncontrol.com.my

MEXICOEL CRISOL, S.A. DE C.V. – LMexico D.F. 06700 MexicoTel: 01-800-3-CRISOL (274765)E-mail: [email protected]: www.elcrisol.com.mx

EQUIPAR, S.A. DE C.V. – L03100, Mexico, D.F., MexicoTel: (52) 55/5420-9901E-mail: [email protected]: www.equipar.com.mx

PROVEEDOR CIENTIFICO, S.A. – L14330 Mexico D.F., MexicoTel: (52) 55/5483-1050E-mail: [email protected]: www.proveedorcientifico.com.mx

REACTIVOS Y EQUIPO, SA DE CV - LMonterrey, Nuevo Leon, 64630 MexicoTel: (52) 81/8333-6691E-Mail: [email protected]: www.reactivosyequipos.com.mx

MEXICO, ECUADOR, PANAMAGRUPO MAGNACOLOR, S.A. DE C.V. – P52937 Atizapan, Edo. De MexicoTel: (52) 55/5308-09-41E-mail: [email protected]: grupomagnacolor.com

NETHERLANDSBENELUX SCIENTIFIC BV – LNL-4051 AP Ochten, NetherlandsTel: (31) 344/655556E-mail: [email protected]: www.brookfield.nl

ELSCOLAB NETHERLANDS B.V – P3542 CA Utrecht, NetherlandsTel: (31) 30/241-4200E-mail: [email protected]: www.elscolab.nl

NEW ZEALANDBIOLAB LTD – L, PAuckland 0745, New ZealandTel: (64) 9/980-6753E-mail: [email protected]: www.biolabgroup.com

NORWAYNERLIENS MESZANSKY LABOREL AS – L, P0654 Oslo, NorwayTel: (47) 22/666500E-mail: [email protected]: www.nmas.no

PAKISTANRAYS TECHNOLOGIES – LLahore, PakistanTel: (92) 42/637-1244, 637-4163E-mail: [email protected]: www.raystechno.com

PARAGUAYSIREX PARAGUAY – LMontevideo, UruguayTel: (598) 2/400-3854

Brookfield Dealers

Page 75: BEL Catalog 2008

75

PERUARSA REPRESENTACIONES – LLima 27, PeruTel: (51) 1/4221167E-mail: [email protected]: www.arsarep.com.pe

PHILIPPINESDAKILA TRADING CORPORATION – LMandaluyong City 1550, PhilippinesTel: (63) 2/724-7511 to 16E-mail: [email protected]: www.dakila.com

OPTIMA EQUIPMENT CORPORATION – PSalcedo Village, Makati City, PhilippinesTel: (63) 2/8173130/8173135E-mail: [email protected]

GOLDEN BAT (FAR EAST) INC. – LQuezon City, PhilippinesTel: (63) 2/731-9745 / 731-9746E-mail: [email protected]: www.goldenbat.ph

POLANDLABO PLUS LTD. – L, P02-952 Warszawa, PolandTel: (48) 22/646-7727E-mail: [email protected]: www.laboplus.pl

PORTUGALSOQUÍMICA – L1500-207 Lisboa, PortugalTel: (351) 21/711 9300E-mail: [email protected]: www.soquimica.pt

PUERTO RICOPUERTO RICO PROCESS TECHNOLOGY, INC. – L,PFajardo, PR 00738Tel: (787) 801-4483E-mail: [email protected]

RUSSIAAVRORA LTD. – LMoscow, 119071, RussiaTel: (7) 495 258-8305/06/07E-mail: [email protected]: www.viscometer.ru

ARGOSY TECHNOLOGIES LTD. – PMoscow, 129110, RussiaTel: 095-510-6236E-mail: [email protected]: www.argosy-tech.ru

SAUDI ARABIAK. I. ABDULKADIR &PARTNERS CO. LTD. – LJeddah 21423, Saudi ArabiaTel: (966) 2/640-5846 Ext. 306E-mail: [email protected]: www.kiaksa.com

AL-ABDULKARIM TRADING – PDammam Saudi ArabiaTel: (966) 3/833-7110E-mail: [email protected]: www.akte.com.sa

SERBIA, MONTENEGROMEDIA ZEMUN DOO – L,P11080 Beograd, SerbiaTel: (381) 11/261-4729E-mail: [email protected]: www.mediazemun.com

SINGAPOREMECOMB SINGAPORE LIMITED – LSingapore 589472Tel: (65) 6469-8833E-mail: [email protected]: www.mecomb.com.sg

PRECISION CONTROL PTE. LTD. – PSingapore 369561Tel: (65) 6285-3011E-mail: [email protected]: www.precisioncontrol.com.sg

SLOVAK REPUBLICECOTEST, S.R.O. – L955 01 Topolcany, Slovak RepublicTel: (421) 38/532-0171 / 2E-mail: [email protected]: www.ecotest.sk

SLOVENIA/CROATIA/BOSNIA-HERZEGOVINALABSYS, LJUBLJANA, D.O.O. – L,P1000 Ljubljana, SloveniaTel: (386) 1/511-2559E-mail: [email protected]: www.labsys.si

SOUTH AFRICAMONITORING & CONTROLLABORATORIES (PTY) LTD. – LLyndhurst 2106, South AfricaTel: (27) 11/327-6524E-mail: [email protected]: www.moncon.co.za

WIRSAM SCIENTIFIC & PRECISIONEQUIPMENT (PTY) LTD. – PAuckland Park 2006, South AfricaTel: (27) 11-482 1060/5E-mail: [email protected]: www.wirsam.com

SPAINMAB INDUSTRIAL, S.A.U. – L,P08029 Barcelona, SpainTel: (34) 93/430- 8301E-mail: [email protected]: www.mabindustrial.es

SRI LANKAHEMSONS INTERNATIONAL (PTE) LTD – LColombo 1, Sri LankaTel: (94) 11/232-7948 / 232-3308E-mail: [email protected]: www.hemsons.lk

SWEDENCHEMICAL INSTRUMENTS AB – LSE-191 49 Sollentuna, SwedenTel: (46) 8/5448-1260E-mail: [email protected]: www.ciab.se

CHEMO-INVEST – PS-250 23 Helsingborg, SwedenTel: (46) 42-150810E-mail: [email protected]: www.chemp-invest.se

SWITZERLANDHUNTER & CAPREZ AG – L,PCH-8126 Zumikon, SwitzerlandTel: (41) 44/918-0808E-mail: [email protected]: www.huntercaprez.com

TAIWANCHIN CHI TECHNOLOGY CO., LTD. – LHsinchuang Taipei Hsien, Taiwan,ROCTel: (886) 2/2299-7300E-mail: [email protected]: www.chinchi-tech.com.tw

TODAY’S INSTRUMENTS CO., LTD. – L,PLin-Kou Township, Taipei County, Taiwan,R.O.C.Tel: (886) 2/2603-2311E-mail: [email protected]: www.todays.com.tw

THAILANDPRECISION CONTROL LTD. – PBangkok, 10800 ThailandTel: (66) 2/910-5280E-mail: [email protected]: www.precisioncontrol.com.sg

SCIENTIFIC PROMOTION CO., LTD. – LPrakanong, Bangkok 10260, ThailandTel: (66) 2/185-4333E-mail: [email protected]: www.spcgroup.co.th

TURKEYARIF SALTUK LTD. STI. – L,P80220 Nisantasi Istanbul, TurkeyTel: (90) 212/233-9504E-mail: [email protected]: www.arifsaltuk.com

UKRAINETEC ENGINEERING LTD. – LKiev, Ukraine, 02140Tel: (38) 44/496-2690E-mail: [email protected]: www.tec.com.ua

UNITED ARAB EMIRATES, OMAN, QATAR, BAHRAIN, KUWAIT, YEMENVENKTRON ELECTRONICS L.L.C. – L,PSharjah, United Arab EmiratesTel: (971) 6/532-9797E-mail: [email protected]: www.venktron.com

UNITED KINGDOMBROOKFIELD VISCOMETERS LIMITED – LHarlow, Essex CM19 5TJ, EnglandTel: (44) 1279/451774E-mail: [email protected]: www.brookfield.co.uk

FULLBROOK SYSTEMS LIMITED – PHerts HP1 2UJ, EnglandTel: (44) 1-442-876777E-mail: [email protected]: www.fullbrooksystems.co.uk

URUGUAYLABIMED SA - LMontevideo 11200, UruguayTel: (598) 2/903-2902E-mail: [email protected]: www.labimed.com.uy

VENEZUELADIDACTA, C.A. – LCaracas, VenezuelaTel: (58) 212/278-5811E-mail: [email protected]: www.didacta.com.ve

VIETNAMNANOGEN PHARMACEUTICAL BIOTECHNOLOGY LTD. – LHochiminh City, VietnamTel: (84) 8/861-1388/978-5088E-mail: [email protected] /[email protected]

RONG TIEN CO., LTD – LHochiminh City, VietnamTel: (84) 8/845-7084E-mail: [email protected]: www.rongtien.com

Brookfield Dealers

Brookfield Viscometers Limited 1 Whitehall Estate, Flex Meadow, Pinnacles WestHarlow, Essex CM19 5TJ, EnglandTel: 1279/451774 Fax: 1279/451775E-mail: [email protected]: www.brookfield.co.uk

Brookfield Engineering Laboratories, Inc.Midwest Regional Office 303 N. Eastwood AvenueMt. Prospect, IL 60056 USATel: (847) 368-8472 Fax: (847) 368-8475E-mail: [email protected]: www.belusa.com

Guangzhou Brookfield Viscometers and Texture Instruments Service Co. Ltd. Room C, 5/F, Tianxing Building East Tower, No. 21, Zhongshan Yi Road,Yuexiu District,Guangzhou, 510600, P.R.ChinaTel: (86) 20/3760-0548; -0995; -8953Fax: (86) 20/3760-0548; -8953; -0995E-mail: [email protected]: www.brookfield.com.cn

Brookfield Engineering Labs. Vertriebs GmbH Hauptstrasse 18D-73547 Lorch, GermanyTel: 7172/927100 Fax: 7172/927105E-mail: [email protected]: www.brookfield-gmbh.de

Page 76: BEL Catalog 2008

Brookfield Engineering Laboratories, Inc. 11 Commerce Boulevard, Middleboro, MA 02346-1031 USAT: 800.628.8139 or 508.946.6200 F: 508.946.6262 W: www.brookfieldengineering.com