Electrical switching takes place every time a control system as-
sumes control or automatic functions. Remote control switches
for pulse control or Insta contactors switch the loads. The
range of different demands ask for a broad spectrum of differ-
ent contacts and rated currents.
When things start hotting up:
bet_07_seite2.fm Seite 2 Mittwoch, 16. Februar 2005 1:16 13
7/3
7
BETA Electrical Switching
Everything runs automatically.
bet_07_seite3.fm Seite 3 Mittwoch, 16. Februar 2005 1:23 13
Product overview
7/4 Siemens ET B1 · 2005
Switching Devices
■ Overview
DefinitionsIe = Rated operational currentUe = Rated operational voltageIc = Rated control supply currentUc = Rated control supply voltagePs = Rated operational capacity1 MW = 18 mm modular width
Uniform mounting depthFitted with a transparent cap, these devices have the same uniform mounting depth valid for all products.
Devices Application Standards Usage
No
n-r
es. b
uild
ing
s
Res
. bu
ildin
gs
Ind
ust
ry
Remote-control switches
• without central switching Switching of lighting by pushbutton DIN EN 61095 (VDE 0637)DIN EN 60669 (VDE 0632)
• •
• with central switching •
• with central and group switching •
Blind and series remote-control switch • •
Electronic series remote-control switch •
Flush-mounting remote-control switches • •
System remote-control switches
• without central switching • •
• with central switching •
• with central and group switching •
Relays
• for PLCs Switching of small loads or application in controllers
DIN EN 60255 (VDE 0435) • •
• for capacitive loads Specially suited for the switching of luminaires such as fluorescent lamps or high-pressure and metal-halide lamps, with capacitive properties
• •
Insta contactors Switching of motors, heating or lighting, such as fluorescent lamps or filament lamps, and resistive and inductive loads
EN 60947-4-1, EN 60947-5-1, EN 61095
• • •
Soft-starting devices
• 5TT3 441, 230 V AC Protection of machines with transmis-sion, belt or chain drives, conveyor belts, fans, pumps, compressors, pack-ing machines, door operating mecha-nisms
DIN EN 60947-4-2, (VDE 0660 Part 117)
•
• 5TT3 440, 400 V AC •
N-type EMERGENCY-STOP modules
• 5TT5 200, 10 A EMERGENCY-STOP switching of ma- chines in industrial, commercial and private economic applications
acc. to the EC directive for machines 98/37/EG, DIN EN 954-1
• •
Electrical switching There are a number of general operational demands, particularly with regard to the switching of lighting, that need to be taken into consid-eration during planning. The technical background represented here is for illustration and clarification purposes and is intended to help you avoid planning errors and prevent the time and hassle caused by premature failures.
Switching Devices
bet_07_00.fm Seite 4 Mittwoch, 16. Februar 2005 1:24 13
5TT5 remote-control switches
7/5Siemens ET B1 · 2005
Switching Devices 12
345678910111213
■ Overview
Remote-control switches
Blind and series remote control switches
Electronic series remote control switches
Flush-mounting remote control switches
System remote-control switches
5TT5 55TT5 15
5TT5 16 5TT5 650 5TT5 431 5TT5 605TT5 615TT5 62
Manual operation • • – – –
Switch position indication • – – – –
Fuse protected against continuous voltage
• • – • •
For different phases between magnet coil and terminals for central and group input
Yes, 5TT5 15 No no no no yes
Operating noises Standard quiet very quiet quiet very quiet
Short-circuit strength up to 800 A
• – – – –
Switching Devices
bet_07_01.fm Seite 5 Mittwoch, 16. Februar 2005 1:25 13
5TT5 remote-control switches
7/6 Siemens ET B1 · 2005
Switching Devices
■ Selection and ordering data
Version Ue Ie Uc MW Order No. Price PG Weight PS*/ P. unit1 item 1 item
V AC A AC V AC V DC kg Items
5TT5 511
5TT5 150
Remote-control switches with transparent capContact gap 3 mm, short-circuit strength up to 800 A
1 NO contacts 230 16 8 – 1 5TT5 511 027 0.090 1/1212 – 5TT5 501 027 0.090 1/12
– 12 5TT5 551 027 0.090 1/12
24 24 5TT5 521 027 0.090 1/12110 110 5TT5 541 027 0.090 1/12230 220 5TT5 531 027 0.090 1/12
2 NO contacts 400 16 8 – 1 5TT5 512 027 0.097 1/1212 – 5TT5 502 027 0.097 1/12
– 12 5TT5 552 027 0.097 1/12
24 24 5TT5 522 027 0.097 1/12110 110 5TT5 542 027 0.097 1/12230 220 5TT5 532 027 0.097 1/12
1 CO contact 230 16 8 – 1 5TT5 516 027 0.091 1/1212 – 5TT5 506 027 0.091 1/1224 24 5TT5 526 027 0.091 1/12
110 110 5TT5 546 027 0.091 1/12230 220 5TT5 536 027 0.091 1/12
with central switching, contact gap 3 mm, short-circuit strength up to 800 A
1 CO contact 230 16 230 – 1 5TT5 535 027 0.091 1/12
2 NO contacts 400 16 230 – 1 5TT5 534 027 0.114 1/12
3 NO contacts 400 16 230 – 2 5TT5 537 027 0.137 1/6
with central and group switching, µ-contact, very quiet operation
1 NO contacts 230 16 24 – 2 5TT5 150 027 0.150 1230 – 5TT5 151 027 0.150 1
2 NO contacts 230 16 24 – 2 5TT5 152 027 0.150 1230 – 5TT5 153 027 0.150 1
5TT5 503
Remote-control switches without transparent capContact gap 3 mm, short-circuit strength up to 800 A
3 NO contacts 400 16 22 – 2 5TT5 503 027 0.150 1/624 24 5TT5 523 027 0.150 1/6
110 110 5TT5 543 027 0.150 1/6
230 230 5TT5 533 027 0.150 1/6
5TT5 163
Blind remote-control switch with transparent capContact sequence 1 – 0 – 2 – 0, contact gap 3 mm
2 NO contacts 230 16 230 – 1 5TT5 163 027 0.100 1
5TT5 166
Series remote-control switches with transparent capContact sequence 1 – 2 – 1 + 2 – 0, contact gap 3 mm
2 NO contacts 230 16 12 – 1 5TT5 166 027 0.100 124 – 5TT5 165 027 0.100 1
230 – 5TT5 164 027 0.100 1
* You can order this quantity or a multiple thereof.
bet_07_01.fm Seite 6 Mittwoch, 16. Februar 2005 1:25 13
5TT5 remote-control switches
7/7Siemens ET B1 · 2005
Switching Devices 12
345678910111213
* You can order this quantity or a multiple thereof.
■ Selection and ordering data
Version Ue Ie Uc MW Order No. Price PG Weight PS*/ P. unit1 item
V AC A AC V AC V DC 1 item kg Items
5TT5 650
Electronic series remote-control switch with transparent cap
Contact sequence 1 – 2 – 1 + 2 – 0, µ-contacts
2 NO contacts 230 16 12 – 1 5TT5 650 027 0.100 1
5TT5 601
5TT5 613
5TT5 621
Remote-control system switches with transparent cap µ-contact, very quiet operation
1 NO contact 230 16 24 – 1 5TT5 601 027 0.065 1230 – 5TT5 602 027 0.065 112 – 5TT5 603 027 0.073 1
with 2 switching systems
1 NO contact per switching system
230 10 24 – 1 5TT5 605 027 0.080 1230 – 5TT5 606 027 0.065 112 – 5TT5 607 027 0.073 1
with central switching
1 NO contact 230 10 230 – 1 5TT5 611 027 0.065 1
with central switching, with 2 switching systems
1 NO contact per switching system
230 8 230 – 1 5TT5 612 027 0.080 1
with central switching, with 3 switching systems
1 NO contact per switching system
230 10 230 – 2 5TT5 613 027 0.140 1
with central switching, with 3 switching systems
1 NO contact per switching system
230 10 230 – 2 5TT5 614 027 0.160 1
with central and group switching with transparent cap
1 NO contact 230 10 230 – 1 5TT5 621 027 0.065 1
with central and group switching, with 3 switching systems
1 NO contact per switching system
230 10 230 – 2 5TT5 623 027 0.140 1
5TG8 230
Compensator, mounting depth 55 mm
PTC resistor combination for increasing glow lamp loads
230 – – – 1 5TG8 230 027 0.050 1
5TG8 236 5TG8 238
Transparent caps
Spare part for devices with an overall width of 1 MW 5TT5 5.Only for devices with an overall width of 1 MW. 1 set(1 set = 5 items) 1 5TG8 236 027 0.025 1 set
Spare part for devices with an overall width of 1 MW 5TT3 0., 5TT3 1, 5TT3 4., 5TT5 1. and 5TT5 6. For devices with an overall width of 2 MW 5TT5 1. you need 2 transparent caps. 1 set(1 set = 5 items) 1 5TG8 237 027 0.025 1 set
Spare part for devices with an overall width of 2 MW 5TT3 4., 5TT5 6. and 5TT6 1. 1 set(1 set = 5 items) 2 ‡ 5TG8 238 027 0.045 1 set
bet_07_01.fm Seite 7 Mittwoch, 16. Februar 2005 1:25 13
5TT3 0 switching relays
7/8 Siemens ET B1 · 2005
Switching Devices
■ Selection and ordering data
1) For spare transparent caps see page 7/7.
Version Ue Ie Uc MW Order No. Price PG Weight 1 item
PS*/ P. unit
V AC A AC V AC V DC 1 item kg Items
5TT3 041
5TT3 061
Switching relay with transparent cap 1)
1 NO contact 230 16 8 – 1 5TT3 041 027 0.100 112 – 5TT3 042 027 0.100 124 – 5TT3 043 027 0.100 1
110 – 5TT3 044 027 0.100 1230 – 5TT3 045 027 0.100 1
2 NO contacts 230 16 8 – 1 5TT3 051 027 0.100 112 – 5TT3 052 027 0.100 124 – 5TT3 053 027 0.100 1
110 – 5TT3 054 027 0.100 1230 – 5TT3 055 027 0.100 1
1 CO contact 230 16 8 – 1 5TT3 061 027 0.100 112 – 5TT3 062 027 0.100 124 – 5TT3 063 027 0.100 1
110 – 5TT3 064 027 0.100 1230 – 5TT3 065 027 0.100 1
2 CO contacts 230 16 8 – 1 5TT3 071 027 0.100 112 – 5TT3 072 027 0.100 124 – 5TT3 073 027 0.100 1
110 – 5TT3 074 027 0.100 1230 – 5TT3 075 027 0.100 1
for control with direct voltage
2 CO contacts 230 16 – 12 1 5TT3 078 027 0.105 1– 24 5TT3 076 027 0.100 1
– 30 5TT3 082 027 0.120 1– 110 5TT3 077 027 0.100 1
for switching capacitive loads; of lighting
1 NO contact 230 16 230 – 1 5TT3 081 027 0.100 1
for control of PLCsContact: 15 to 60 V, 2 to 30 mA according to EN 61131-2, type 1
1 NO contact 230 16 230 – 1 5TT3 085 027 0.110 1
5TT3 080
Sealable enable relay, mounting depth 55 mm
Used for boiler/storage relays.In the case of continuous duty, a distance of 1 MW must be maintained between the devices.
1 CO contact 230 16 230 – 1 5TT3 080 027 0.100 1
Switching Devices
* You can order this quantity or a multiple thereof.
bet_07_02.fm Seite 8 Mittwoch, 16. Februar 2005 1:25 13
5TT5 7 Insta contactors
7/9Siemens ET B1 · 2005
Switching Devices 12
345678910111213
■ Selection and ordering data
1) For NC contacts 30 A.
Version Ue Ie Uc MW Order No. Price PG Weight 1 item
PS*/ P. unit
V AC A AC V AC V DC 1 item kg Items
5TT5 700-0
5TT5 730-0
5TT5 740-0
Insta contactor
for alternating current continuous operation, with switch position indication, with alternating current magnet system
2 NO contacts 250 20 230 – 1 5TT5 700-0 027 0.132 124 – 5TT5 700-2 027 0.132 1
1 NO contact, 1 NC contact
250 20 230 – 1 5TT5 701-0 027 0.132 1
24 – 5TT5 701-2 027 0.132 1
2 NC contacts 250 20 230 – 1 5TT5 702-0 027 0.132 124 – 5TT5 702-2 027 0.132 1
for AC or DC continuous operation, with switch position indication, with DC magnet system
4 NO contacts 440 24 230 220 2 5TT5 730-0 027 0.247 1115 110 5TT5 730-1 027 0.247 124 24 5TT5 730-2 027 0.247 1
3 NO contacts, 1 NC contact
440 24 230 220 2 5TT5 731-0 027 0.247 1
24 24 5TT5 731-2 027 0.247 1
2 NO contacts, 2 NC contacts
440 24 230 220 2 5TT5 732-0 027 0.247 1
24 24 5TT5 732-2 027 0.247 1
4 NC contacts 440 24 230 220 2 5TT5 733-0 027 0.247 124 24 5TT5 733-2 027 0.247 1
4 NO contacts 440 40 230 220 3 5TT5 740-0 027 0.410 124 24 5TT5 740-2 027 0.410 1
3 NO contacts, 1 NC contact
440 401) 230 220 3 5TT5 741-0 027 0.410 1
24 24 5TT5 741-2 027 0.410 1
2 NO contacts, 2 NC contacts
440 401) 230 220 3 5TT5 742-0 027 0.410 1
24 24 5TT5 742-2 027 0.410 1
4 NO contacts 440 63 230 220 3 5TT5 750-0 027 0.410 124 24 5TT5 750-2 027 0.410 1
3 NO contacts, 1 NC contact
440 631) 230 220 3 5TT5 751-0 027 0.410 1
24 24 5TT5 751-2 027 0.410 1
2 NO contacts, 2 NC contacts
440 631) 230 220 3 5TT5 752-0 027 0.410 1
24 24 5TT5 752-2 027 0.410 1
5TT5 900
Auxiliary switch
for left-sided mounting on the 24-A, 40-A and 63-A Insta contactor; max. one auxiliary switch per Insta contactor. Minimum contact load 24 V AC; 5 mA
2 NO contacts 230, AC-15 4 0.5 5TT5 900 027 0.039 1
1 NO contact, 1 NC contact
230, AC-15 4 0.5 5TT5 901 027 0.039 1
5TG8 240
Spacer
for heat conduction between the Insta contactors. We recommend placing a spacer between each second Insta contactor. Can be mounted reciprocally, so that two spacers enable greater cable penetration
0.5 5TG8 240 027 0.010 2
5TT5 903
Sealable terminal covers 1 set
for Insta contactor 24 A, (1 set = 2 items) 2 5TT5 902 027 0.010 1 set
1 setfor Insta contactors 40 A and 63 A, (1 set = 2 items) 3 5TT5 903 027 0.010 1 set
Switching Devices
* You can order this quantity or a multiple thereof.
bet_07_03.fm Seite 9 Mittwoch, 16. Februar 2005 1:25 13
5TT3 4 soft-starting devices
7/10 Siemens ET B1 · 2005
Switching Devices
* You can order this quantity or a multiple thereof.
■ Overview• 1-phase 1.5 kW• 3-phase 5.5 kW• Increases the service life of one-phase asynchronous motors and
mechanical drive equipment• Can also be retrofitted in existing systems
• Separate setting of acceleration time and starting torque• With LED display for startup or continuous operation• The power semiconductors are bridged after completion of start-
up.
■ Selection and ordering data
1) For spare transparent caps see page 7/7.
Version Ue Pc MW Order No. Price PG Weight 1 item
PS*/ P. unit
V AC W 1 item kg Items
5TT3 441
Soft-starting device with transparent cap 1)
1-phase 230 100 ... 1 500 2 5TT3 441 027 0.135 1
5TT3 440
Soft-starting device, mounting depth 55 mm
3-phase, 2-phase motor actuation 400 300 ... 5 500 6 5TT3 440 027 0.430 1
NL1
T2T1
I2_07513
tacc Mst
tacc: Acceleration time
Mst: Starting torque
A
L1L2L3
T1T2T3
I2_07514
tacc Mst
tacc: Acceleration time
Mst: Starting torque
A
Switching Devices
bet_07_04.fm Seite 10 Mittwoch, 16. Februar 2005 1:26 13
5TT5 2 EMERGENCY-STOP modules
7/11Siemens ET B1 · 2005
Switching Devices 12
345678910111213
■ Overview
ScopeThe scope of the EC Directive Machines is no longer restricted to in-dustrial machinery, but now covers virtually all machines for use in all areas of commercial and private trade and industry and applies to all• Stationary• Movable,• Hand-held,• Mobile• Machine tools and processing machines• Prime movers and production machines
• Compressors• Operating and packaging machines• Machines in underground mining• Earthmoving machines and harvesters• Hoisting equipment• Floor conveyors• Machines for lifting persons• Plants• Interchangeable equipment, such as snow ploughs and mount-
able sweeping devices
Risk analysis and selection of a suitable categoryEngineers and operators assume responsibility for the correct risk assessment.It is difficult to make a quantitative assessment of the risk, so that when selecting the category, the reasonable risk can be determined within a broad band width.
This becomes clear if you select "F2 - frequently to continuous" in-stead of "F1 - rarely to frequently", for the risk parameters "F - Fre-quency and duration" when drawing up a risk graph (see image).The whole band width of safety categories may lie between the as-sessment of "often" and "frequently".
■ Benefits• Acc. to the 98/37/EC EC directive for machines• Safety category 4 acc. to DIN EN 954-1• Acc. to the 98/37/EC EC directive for machines
• Safety category 4 acc. to DIN EN 954-1• Electrical isolation between electric circuit and control• LED display for operation and circuit state
■ Selection and ordering data
I2_0
8404
a
B 1 2 3 4
minor injury
serious and irreversible injury of one or several persons or death of a person
rarely to frequently
frequently to constantly
possible under certain circumstances
possible under certaincircumstances
hardly possible
preferred categories for reference points
possible category which requiresadditional measures with regard to the risk
overdimensioned measures with regard to the risk
Categories
hardly possible
seriousness of injuryRisk parameter F: Risk parameter P:frequency andduration
possibility of avoiding injuries
Risk parameter S:
Version Ue Ie Uc MW Order No. Price PG Weight 1 item
PS*/ P. unit
V AC A V AC 1 item kg Items
5TT5 200
EMERGENCY-STOP module, mounting depth 55 mm
400 5 230 4 5TT5 200 027 0.250 1