New Touch Screen Boiler Controller
Express set up - Remote monitoring & diagnostics
Easy USB programmability - True native BACnet
Intuitive alert system
Easy homeowner DHW temp adjust
VFC 15-150 became the first and industry leading 10:1 turndown ratio residential-scale modulating boiler in North America. Spans the range from small cottage to sprawling mansion.
Sustained high efficiency across firing range even at high temperatures.
Now featuring multiple zone pump control - up to 4 zones replacing the need for external pump controls.
Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler.
Unmatched durability from our exclusive 316Ti stainless steel 80psi “Super Coil” heat exchanger.
Controls 5 independent pumps directly from the boiler without additional relays.
Go anywhere venting options up to 480 feet! IBC boilers are not de-rated because of longer vent runs.
Limited lifetime residential heat exchanger warranty. See website for details.
Premier Boilers
Better Boilers
ibcboiler.com ibcboiler.com ibcboiler.com
VFC 15-150
Express Setup
Menu
IBC 04:30
Load Status
User Setup
Installer Setup
Diagnostics
Back
45,000 to 225,000 BTU/H
Condensing Boilers
VFC 45-225 15,000 to 150,000 BTU/H
H
5 YEAR LIMITED MANUFACTURER’S
PARTS WARRANTY
MULTIPLE ZONE PUMP CONTROL
UP TO 4 ZONES
MFZ - MOISTURE FREE ZONE
MANAGEMENT TECHNOLOGY
Head Offices 8015 North Fraser Way, Burnaby, B.C., Canada V5J 5M8 Tel: 604 877 0277 Fax: 604 877 0295
4203 Industrial Court, Sheboygan, WI 53083 Tel: 920 783 8340 Fax: 920 783 8339
www.ibcboiler.com
Better Boilers
VFC 15-150 / VFC 45-225 Condensing Boiler
Natural Gas boilers require a Propane conversion kit - Part #P174 to be ordered separately if converting a boiler from
Natural Gas to Propane. Propane boilers require a Natural Gas conversion kit - Part # P176 to be ordered separately if
converting a Propane boiler to Natural Gas.
Boilers are shipped with 30psi pressure relief valve.
Specifications VFC 15-150 VFC 45-225
CSA Input (Natural Gas or Propane *) - MBH 15 - 150 45 - 225
CSA Input (Natural Gas or Propane *) - KW 4.4 - 44 13 - 66
CSA Output - MBH 14 - 139 12 - 60
CSA Output - KW 4.1 - 41 12.7 - 70.0
A.F.U.E 95% 95%
Min gas pressure (Nat. Gas or Propane) - inch w.c. 5 5
Max gas pressure (Nat. Gas or Propane) - inch w.c. 14 14
Power (120Vac/60Hz) - Watts @ full fire - Watts 57 57
Weight (empty) - lbs/Kg 150 / 68 153 / 70
Pressure vessel water content – USG/Liters 2.4 / 9 2.4 / 9
Min boiler flow rate - USgpm 4 8
Max boiler flow rate - USgpm 16 25
Max operating pressure - psig 80 80
Min water pressure - psig 8 8
Normal flue temp @ 100°F boiler return water temp - High Fire 100°F to 105°F 100°F to 105°F
Normal flue temp @ 160°F boiler return water temp - High Fire 160°F to 165°F 160°F to 165°F
Approved installation altitude - ASL 0 - 12,000 ft 0 - 12,000 ft
Ambient temperature - Low (°F/°C) 32°F / 0°C 32°F / 0°C
Ambient temperature - High (°F/°C) 122°F / 50°C 122°F / 50°C
Max relative humidity (non-condensing) 90% 90%
Min water temperature (°F/°C) 34°F / 1°C 34°F / 1°C
Max water temperature (electronic-limit) (°F/°C) 190°F / 88°C 190°F / 88°C
Max water temperature (mechanical hi-limit) (°F/°C) 200°F / 93°C 200°F / 93°C
Max ΔT - supply / return (electronic fence) 40°F 40°F
Maximum equivalent vent length each side 2” 50' N/A
Maximum equivalent vent length each side 3” 120' 240'
(Natural Gas or Propane)
Air intake options: either direct vent or indoor supply
Boiler Head Loss
Flow rate (gpm) 4 8 12 16 20
Head loss @ flow (ft wc) 0.7’ 2.5’ 5.0’ 8.3’ 12.3’
Pressure vessel head loss
Description VFC
A Water outlet 1 1/4” NPT - M
B Water inlet 1 1/4” NPT - M
C Gas inlet 1/2” NPT - M
D Knock-outs (6) 1/2”
E Touch screen display 2-1/4” x 4”
F Exhaust vent 4.0” Hole
G Combustion air 4.0” Hole
Surface
Distance from
combustible
surfaces
Recommended distance
for installation and service
Front 2” 24”
Rear 0” 0”
Left side 0” 8” (min. for vent run)
Right side 2” 18”
Top 6” 10”
Exhaust pipe size Maximum equivalent length
Sched.40; Rigid PPs
2” (15-150 only) 50’ (each side)
3” (15-150) 120’
3” (45-225) 240’
90° Vent elbow Allow 8’ equivalent
45° Elbow Allow 3’ equivalent
PP’s 87-90° Elbows Allow 8’ equivalent
Flexible PPs
2” Flexible Not allowed
3” Flexible (VFC 15-150) 60’ (max) Actual lineal x 1.5 = equivalent
3” Flexible (VFC 45-225) 60’ (max) Actual lineal x 3 = equivalent
Note : Unused intake travel cannot be added to the exhaust. Unequal intake and
exhaust piping is allowed
Printed in Canada 12/05/2016