bgc plasterboard fire & acoustic - shg trade solutions brochure... · 2014. 10. 13. · the bgc...

109
Australian Owned & Manufactured www.bgc.com.au/plasterboard www.bgcinnovadesign.com.au BGC PLASTERBOARD FIRE & ACOUSTIC GUIDE MARCH / 2013

Upload: others

Post on 05-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

Australian Owned & Manufactured www.bgc.com.au/plasterboard www.bgcinnovadesign.com.au

BGC PLASTERBOARDFIRE & ACOUSTIC GUIDE

MA

RC

H / 2013

Page 2: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

1

The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers, designers, builders and contractors in the selection of the correct system for projects when fire and acoustic properties are required.

Each of the systems in this Guide has been given a unique system number to help with ease of identification. A quick reference guide to these numbers is noted further in the Guide.

The data contained in this Guide meets all Australian standards and is correct at the time of publication.

SAFETY In normal circumstances there are no known health hazards when using or applying plasterboard. However, BGC Plasterboard recommends that the following precautions are followed.

Avoid creating dust when handling BGC Plasterboard or plasterboard products. BGC Plasterboard suggests that P1 or P2 particulate respirator (dust mask), which comply with Australian and New Zealand Standard AS/NZS 1715: Selection, Use and Maintenance of Respiratory Protective Devices, and Australian and New Zealand Standard AS/NZS 1716: Respiratory Protective Devices when Exposed to Dust), be used at all times.

FIRST AID

Eyes Flush with clean water for 15 minutes. Seek medical attention if irritation persists.

Skin Wash with mild soap and water. Seek medical attention if irritation persists.

Inhalation Drink plenty of water. Seek medical attention.

Material Safety Data Sheets for BGC Plasterboardand BGC Fibre Cement products are available at any BGC state office or the BGC website

www.bgc.com.au/plasterboardwww.bgcinnovadesign.com.au

CERTIFICATION DETAILSAll systems in the BGC Plasterboard Fire and Acoustic Guide have been assessed to meet all requirements of Australian Standards and the Building Code of Australia.

Acoustic testing has been carried out to Australian Standards.

The acoustic testing has been carried out by the following institutions:

• Royal Melbourne Institute of Technology (RMIT)• CSIRO

The fire testing has been carried out to Australian Standard AS1530 – part 4 ‘Fire and Resistance Tests of Elements of Building Construction’ and were carried out by:

• CSIRO• Exova Warringtonfire Aus Pty Ltd.

Fire and acoustic test reports and opinions can be obtained upon request. The systems detailed in this Guide and their warranties are only valid if constructed in accordance with BGC Plasterboardor BGC Fibre Cement installation methods and using only BGC Plasterboard or BGC Fibre Cement products.

BGC manufactures plasterboard and fibre cement products under the rigorous Quality Management System of the International Standard ISO 9001:2008 and is the holder of Licence Agreement numbers QEC 2955/13 and QEC 29633.

INTRODUCTION TO BGC PLASTERBOARD FIRE AND ACOUSTIC GUIDE

Page 3: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

2

PRODUCT & THICKNESS mm

PLASTERBOARD 10mm

PLASTERBOARD 13mm

CEILINGBOARD 13mm

WATER RESISTANT PLASTERBOARD 10mm

WATER RESISTANT PLASTERBOARD 13mm

FIREBOARD 13mm

FIREBOARD 16mm

CURVEBOARDTM 6.5mm

SOUNDBOARDTM 10mm

SOUNDBOARDTM 13mm

WET AREA FIREBOARD 13mm

WET AREA FIREBOARD 16mm

IMPACTBOARD13mm

BGC ENVIROBOARD COMMERCIAL

BGC ENVIROBOARD ULTIMATE

BGC PRODUCTSBGC PLASTERBOARD

WEIGHT KG/M²

7.00

9.00

7.20

7.80

9.40

10.60

12.70

4.20

9.00

12.50

10.60

12.60

11.50

9.50

10.60

12001350120013501200135012001350120013501200

1200

1200

120013501200

1200

1200

1200

1200

1200

WIDTH mm

x

xxxxxxx

x

x

x

x

x

x

x

x

x

x

xxxxxxx

xxx

x

x

x

x

xxxxxxxxxxx

x

x

x

x

x

x

x

x

x

xxxxxx

xxxx

xxxxxxxx

xx

x

x

x

xxx

xxxx

2400 2700 3000 3600 4200 4800 5400 6000

LENGTH mm

COMPOUNDSPRODUCT BUCKET/BAG SIZEStud Adhesive 1.25kgStud Adhesive 5.2kgMulti Purpose Joint Compound 6kgMulti Purpose Joint Compound 20kgWater Resistant Taping Cement 1.65kgWater Resistant Taping Cement 6.4kgLightweight All Purpose Compound 15kgTop Coat 20kgBase Coat 45 20kgBase Coat 60 5kgBase Coat 60 10kgBase Coat 60 20kgBase Coat 90 20kgCornice Cement 45 20kgCornice Cement 60 5kgCornice Cement 60 10kgCornice Cement 60 20kgCornice Cement 90 20kgMasonry Adhesive 20kgBack Blocking Cement 20kgExterior and Wet Area Base Coat 12kgExterior and Wet Area Top Coat 13kgFibreglass Tape 50mm x 20mFibreglass Tape 50mm x 90m

Page 4: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

3

x

DURASHEETTM 4.5mm

DURASHEETTM 6.0mm

DURAPLANKTM 7.5MM SMOOTH AND

WOODGRAINDURAPLANKTM 7.5mm

RUSTICATEDNULINETM PLUS 14.0mm

DURATEXTM 7.5mm

DURATEXTM 9.0mmDURALATTICETM 6.0mm

DURAGRIDTM 9.0mm

DURACOMTM 9.0mm

DURACOMTM 12.0mmDURASCAPETM 9.0mm

DURAGROOVETM 9.0mmCOMPRESSED 15.0mm

COMPRESSED 18.0mm

COMPRESSED 24.0mmDURALINERTM 6.0mm

DURALINERTM 9.0mm

DURALINERTM 12.0mmDURALUXTM 4.5mm

DURALUXTM 6.0mm

*DURALUXTM 9.0mmCTU 6.0mm

VCU 5.0mmSTONESHEETTM 9.0mm

* Available only in Queensland

PRODUCT & THICKNESS mm

WEIGHT KG/M²

7.58

10.00

2.903.80

2.50

4.834.1312.5

15.387.69

11.70

16.95

22.7312.50

12.5028.57

34.48

47.6210.00

15.38

19.007.4

9.52

159.52

8.3315.38

1200900750600450

1200900300230

205

205175

1200900

12001200900

29901190890590

1200900

12001200900

12001200900

1200900

1200900

120013501200135012001200900

1200900

12001200900900

1200

WIDTH mm

xx

xx

x

x

xx

xxxx

x

xx

x

xxxx

x

xxx

x

x

xx

xxx

xx

x

x

xx

x

x

x

x

x

xx

x

xx

xx

xxx

xxxxxxxxxx

xxxxxxx xxx

x

xxxxxxx

xxx

xxx

xxxxxxxxx

xxx x

xxxx

xxx

xx

x

xx

xx

1190 1200 1500 1790 1800 2100 2390 2400 2440 2450 2700 2725 2750 3000 3600 4200 4800 5400 6000

LENGTH mm

BGC PRODUCTSBGC FIBRE CEMENT

Page 5: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

4

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER1 x 10mm BGC Plasterboard 1 x 10mm BGC Plasterboard -/-/- S001 271 x 13mm BGC Plasterboard 1 x 13mm BGC Plasterboard -/-/- S002 272 x 13mm BGC Plasterboard 1 x 13mm BGC Plasterboard -/-/- S003 272 x 13mm BGC Plasterboard 2 x 13mm BGC Plasterboard -/-/- S005 281 x 10mm BGC SoundboardTM 1 x 10mm BGC SoundboardTM -/-/- S006 281 x 13mm BGC SoundboardTM 1 x 13mm BGC SoundboardTM -/-/- S007 282 x 10mm BGC SoundboardTM 1 x 10mm BGC WR Plasterboard -/-/- S009 292 x 10mm BGC SoundboardTM 2 x 10mm BGC SoundboardTM -/-/- S010 291 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard -/60/60 S011 291 x 13mm BGC Fireboard 1 x 10mm BGC Plasterboard 1 x 13mm BGC Fireboard -/60/60 S012 301 x 13mm BGC Fireboard 2 x 13mm BGC Fireboard -/60/60 S018 301 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard -/60/60 60/60/60 S019 302 x 13mm BGC Fireboard 2 x 13mm BGC Fireboard -/120/120 S021 312 x 16mm BGC Fireboard 2 x 16mm BGC Fireboard -/120/120 90/90/90 S023 313 x 13mm BGC Fireboard 3 x 13mm BGC Fireboard - /120/120 S025 313 x 16mm BGC Fireboard 3 x 16mm BGC Fireboard -/180/180 S026 321 x 6mm BGC DuralinerTM 1 x 6mm BGC DuralinerTM -/-/- S027 321 x 9mm BGC DuralinerTM 1 x 9mm BGC DuralinerTM -/-/- S028 321 x 12mm BGC DuralinerTM 1 x 12mm BGC DuralinerTM -/-/- S029 331 x 10mm BGC SoundboardTM 1 x 6mm BGC DuralinerTM -/-/- S031 331 x 13mm BGC Plasterboard 1 x 6mm BGC DuralinerTM -/-/- S033 331 x 13mm BGC Plasterboard 1 x 9mm BGC DuralinerTM -/-/- S034 341 x 13mm BGC Fireboard 1 x 6mm BGC DuralinerTM -/-/- S035 341 x 16mm BGC Fireboard (against studs) 1 x 16mm BGC Fireboard (against studs) 1 x 9mm BGC DuralinerTM 1 x 9mm BGC DuralinerTM -/60/60 S041 341 x 9mm BGC DuralinerTM (against studs) 1 x 9mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard 120/120/120 S043 352 x 16mm BGC Wet Area Fireboard 2 x 16mm BGC Wet Area Fireboard -/180/180 S044 35----- 3 x 16mm BGC Wet Area Fireboard -/120/120 120/120/120 S045 36----- 2 x 16mm BGC Fireboard -/60/60 S046 36----- 3 x 16mm BGC Fireboard -/120/120 120/120/120 - S048 36

QUICK REFERENCE GUIDESTEEL FRAME - SINGLE STUD

QUICK REFERENCE GUIDESTEEL FRAME - STAGGERED STUD

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER1 x 10mm BGC Plasterboard 1 x 10mm BGC Plasterboard -/-/- SS001 371 x 13mm BGC Plasterboard 1 x 13mm BGC Plasterboard -/-/- SS002 371 x 10mm BGC SoundboardTM 1 x 10mm BGC SoundboardTM -/-/- SS006 371 x 13mm BGC SoundboardTM 1 x 13mm BGC SoundboardTM -/-/- SS007 382 x 10mm BGC SoundboardTM 2 x 10mm BGC SoundboardTM -/-/- SS010 381 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard -/60/60 SS011 381 x 13mm BGC Fireboard 1 x 13mm BGC Plasterboard 1 x 13mm BGC Fireboard -/60/60 SS014 392 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard -/60/60 SS018 391 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard -/60/60 SS019 391 x 16mm BGC Fireboard 1 x 13mm BGC Fireboard 1 x 16mm BGC Fireboard -/60/60 SS020 40 2 x 13mm BGC Fireboard 2 x 13mm BGC Fireboard -/120/120 SS021 402 x 16mm BGC Fireboard 2 x 16mm BGC Fireboard -/120/120 SS023 403 x 16mm BGC Fireboard 3 x 16mm BGC Fireboard -/180/180 SS026 411 x 9mm DuralinerTM 1 x 9mm BGC DuralinerTM -/-/- SS028 412 x 10mm BGC SoundboardTM 1 x 6mm BGC DuralinerTM -/-/- SS032 411 x 13mm BGC Plasterboard 1 x 6mm BGC DuralinerTM -/-/- SS033 421 x 13mm BGC Plasterboard 1 x 9mm BGC DuralinerTM -/-/- SS034 421 x 13mm BGC Fireboard 1 x 6mm BGC DuralinerTM -/-/- SS035 421 x 9mm BGC DuralinerTM 1 x 16mm BGC Fireboard -/-/- SS036 431 x 16mm BGC Fireboard (against studs) 1 x 16mm BGC Fireboard (against studs) 1 x 9mm BGC DuralinerTM 1 x 9mm BGC DuralinerTM -/60/60 SS041 431 x 9mm BGC DuralinerTM (against studs) 1 x 9mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard 120/120/120 SS043 43

Page 6: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

5

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER1 x 10mm BGC Plasterboard 1 x 10mm BGC Plasterboard -/-/- T001 551 x 13mm BGC Plasterboard 1 x 13mm BGC Plasterboard -/-/- T002 552 x 10mm BGC Plasterboard 2 x 10mm BGC Plasterboard -/-/- T004 552 x 13mm BGC Plasterboard 2 x 13mm BGC Plasterboard -/-/- T005 561 x 10mm BGC SoundboardTM 1 x 10mm BGC SoundboardTM -/-/- T006 561 x 13mm BGC SoundboardTM 1 x 13mm BGC SoundboardTM -/-/- T007 561 x 10mm BGC SoundboardTM 1 x 10mm BGC WR Plasterboard -/-/- T008 572 x 10mm BGC SoundboardTM 2 x 10mm BGC SoundboardTM -/-/- T010 571 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard -/60/60 60/60/60 T011 571 x 13mm BGC Plasterboard 1 x 10mm BGC Plasterboard 1 x 13mm BGC Fireboard -/-/- T015 581 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard -/60/60 60/60/60 T019 582 x 13mm BGC Fireboard 2 x 13mm BGC Fireboard -/120/120 T021 582 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard 60/60/60 T022 592 x 16mm BGC Fireboard 2 x 16mm BGC Fireboard -/120/120 T023 593 x 16mm BGC Fireboard 3 x 16mm BGC Fireboard -/180/180 T026 591 x 6mm BGC DuralinerTM 1 x 6mm BGC DuralinerTM -/-/- T027 601 x 10mm BGC SoundboardTM (against studs) 1 x 10mm BGC SoundboardTM (against studs) 1 x 6mm BGC DuralinerTM 1 x 6mm BGC DuralinerTM -/-/- T037 601 x 6mm BGC DuralinerTM (against studs) 1 x 6mm BGC DuralinerTM (against studs) 1 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard 60/60/60 T039 601 x 6mm BGC DuralinerTM (against studs) 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard 90/90/90 T042 612 x 16mm BGC Wet Area Fireboard 2 x 16mm BGC Wet Area Fireboard -/180/180 T044 61----- 2 x 16mm BGC Fireboard -/60/60 T046 61----- 3 x 16mm BGC Fireboard -/90/90 T048 62

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER3 x 16mm BGC Fireboard 3 x 16mm BGC Fireboard 120/120/120 SC001 504 x 16mm BGC Fireboard 4 x 16mm BGC Fireboard 120/120/120 SC002 50

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER1 x 10mm BGC Plasterboard 1 x 10mm BGC Plasterboard -/-/- SD001 441 x 13mm BGC Plasterboard 1 x 13mm BGC Plasterboard -/-/- SD002 441 x 10mm BGC SoundboardTM 1 x 10mm BGC SoundboardTM -/-/- SD006 441 x 13mm BGC SoundboardTM 1 x 13mm BGC SoundboardTM -/-/- SD007 451 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard -/60/60 SD011 451 x 16mm BGC Fireboard (against studs) 1 x 16mm BGC Fireboard (against studs) 1 x 10mm BGC Plasterboard 1 x 10mm BGC Plasterboard -/60/60 SD016 451 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard -/60/60 60/60/60 SD019 462 x 13mm BGC Fireboard 2 x 13mm BGC Fireboard -/120/120 90/90/90 SD021 462 x 16mm BGC Fireboard 2 x 16mm BGC Fireboard -/120/120 SD023 462 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard -/60/60 SD024 473 x 13mm BGC Fireboard 3 x 13mm BGC Fireboard -/120/120 SD025 473 x 16mm BGC Fireboard 3 x 16mm BGC Fireboard -/180/180 SD026 471 x 6mm BGC DuralinerTM 1 x 6mm BGC DuralinerTM -/-/- SD027 481 x 9mm BGC DuralinerTM 1 x 9mm BGC DuralinerTM -/-/- SD028 481 x 13mm BGC Fireboard (against studs) 1 x 13mm BGC Fireboard (against studs) 1 x 6mm BGC DuralinerTM 1 x 6mm BGC DuralinerTM -/60/60 SD038 481 x 6mm BGC DuralinerTM (against studs) 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard -/60/60 SD042 491 x 9mm BGC DuralinerTM (against studs) 1 x 9mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard 120/120/120 SD043 49

QUICK REFERENCE GUIDETIMBER FRAME - SINGLE STUD

QUICK REFERENCE GUIDESTEEL FRAME - CINEMA WALL

QUICK REFERENCE GUIDESTEEL FRAME - DOUBLE STUD

Page 7: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

6

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER1 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard -/60/60 TD011 681 x 13mm BGC Plasterboard (against studs)1 x 13mm BGC Plasterboard (against studs) 1 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard -/60/60 TD013 681 x 10mm BGC Plasterboard (against studs)1 x 10mm BGC Plasterboard (against studs) 1 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard -/60/60 TD017 681 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard -/60/60 60/60/60 TD019 692 x 13mm BGC Fireboard 2 x 13mm BGC Fireboard -/120/120 TD021 692 x 16mm BGC Fireboard 2 x 16mm BGC Fireboard -/120/120 TD023 693 x 16mm BGC Fireboard 3 x 16mm BGC Fireboard -/120/120 TD026 701 x 6mm BGC DuralinerTM 1 x 6mm BGC DuralinerTM -/-/- TD027 701 x 9mm BGC DuralinerTM 1 x 9mm BGC DuralinerTM -/-/- TD028 701 x 6mm BGC DuralinerTM (against studs) 1 x 6mm BGC DuralinerTM (against studs) 1 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard 60/60/60 TD039 711 x 16mm BGC Fireboard (against studs) 1 x 16mm BGC Fireboard (against studs) 1 x 6mm BGC DuralinerTM 1 x 6mm BGC DuralinerTM 60/60/60 TD040 711 x 6mm BGC DuralinerTM (against studs) 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard 90/90/90 TD042 71

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER1 x 10mm BGC SoundboardTM 1 x 10mm BGC SoundboardTM -/-/- TS006 632 x 10mm BGC SoundboardTM 2 x 10mm BGC SoundboardTM -/-/- TS010 631 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard -/60/60 TS011 631 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard -/90/90 TS019 642 x 13mm BGC Fireboard 2 x 13mm BGC Fireboard -/120/120 TS021 642 x 16mm BGC Fireboard 2 x 16mm BGC Fireboard -/120/120 TS023 641 x 6mm BGC DuralinerTM 1 x 6mm BGC DuralinerTM -/-/- TS027 651 x 9mm BGC DuralinerTM 1 x 9mm BGC DuralinerTM -/-/- TS028 651 x 6mm BGC DuralinerTM 1 x 10mm BGC Plasterboard -/-/- TS030 651 x 6mm BGC DuralinerTM 1 x 10mm BGC SoundboardTM -/-/- TS031 661 x 6mm BGC DuralinerTM (against studs) 1 x 6mm BGC DuralinerTM (against studs) 1 x 13mm BGC Fireboard 1 x 13mm BGC Fireboard 60/60/60 TS039 661 x 16mm BGC Fireboard (against studs) 1 x 16mm BGC Fireboard (against studs) 1 x 6mm BGC DuralinerTM 1 x 6mm BGC DuralinerTM 60/60/60 TS040 661 x 6mm BGC DuralinerTM (against studs) 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard 1 x 16mm BGC Fireboard 90/90/90 TS042 67

QUICK REFERENCE GUIDETIMBER FRAME - STAGGERED STUD

QUICK REFERENCE GUIDETIMBER FRAME - DOUBLE STUD

Page 8: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

7

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER1 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 60/60/60 TE001 751 x 7.5mm DuratexTM 2 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 90/90/90 TE002 751 x 7.5mm DuratexTM 1 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 60/60/60 TE003 751 x 9mm DuragridTM 2 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 90/90/90 TE004 761 x 9mm DuragridTM 1 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 60/60/60 TE005 761 x 9mm DuracomTM 2 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 90/90/90 TE006 761 x 9mm DuracomTM 1 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 60/60/60 TE007 771 x 14mm NulineTM Plus 2 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 90/90/90 TE008 771 x 14mm NulineTM Plus 1 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 60/60/60 TE009 771 x 9mm DurascapeTM 2 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 90/90/90 TE010 781 x 9mm DurascapeTM 1 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 60/60/60 TE011 781 x 9mm DuragrooveTM 2 x 16mm BGC Wet Area Fireboard 1 x 10mm BGC Plasterboard 90/90/90 TE012 781 x 9mm DuragrooveTM

QUICK REFERENCE GUIDEEXTERIOR WALL - TIMBER STUD

QUICK REFERENCE GUIDEEXTERIOR WALL - STEEL STUD

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER1 x 16mm BGC Wet Area Fireboard 1 x 16mm BGC Fireboard 60/60/60 SE001 791 x 7.5mm DuratexTM 2 x 16mm BGC Wet Area Fireboard 2 x 16mm BGC Fireboard 90/90/90 SE002 791 x 7.5mm DuratexTM 1 x 16mm BGC Wet Area Fireboard 1 x 16mm BGC Fireboard 60/60/60 SE003 791 x 9mm DuragridTM 2 x 16mm BGC Wet Area Fireboard 2 x 16mm BGC Fireboard 90/90/90 SE004 801 x 9mm DuragridTM 1 x 16mm BGC Wet Area Fireboard 1 x 16mm BGC Fireboard 60/60/60 SE005 801 x 9mm DuracomTM 2 x 16mm BGC Wet Area Fireboard 2 x 16mm BGC Fireboard 90/90/90 SE006 801 x 9mm DuracomTM 1 x 16mm BGC Wet Area Fireboard 1 x 16mm BGC Fireboard 60/60/60 SE007 811 x 14mm NulineTM Plus 2 x 16mm BGC Wet Area Fireboard 2 x 16mm BGC Fireboard 90/90/90 SE008 811 x 14mm NulineTM Plus 1 x 16mm BGC Wet Area Fireboard 1 x 16mm BGC Fireboard 60/60/60 SE009 811 x 9mm DurascapeTM 2 x 16mm BGC Wet Area Fireboard 2 x 16mm BGC Fireboard 90/90/90 SE010 821 x 9mm DurascapeTM 1 x 16mm BGC Wet Area Fireboard 1 x 16mm BGC Fireboard 60/60/60 SE011 821 x 9mm DuragrooveTM 2 x 16mm BGC Wet Area Fireboard 2 x 16mm BGC Fireboard 90/90/90 SE012 821 x 9mm DuragrooveTM

Page 9: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

8

QUICK REFERENCE GUIDE FLOOR / CEILING - TIMBER OR STEEL JOISTS

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER1 x 13mm BGC Plasterboard -/-/- C001 852 x 13mm BGC Plasterboard -/-/- C002 851 x 10mm BGC Ceilingboard -/-/- C003 852 x 10mm BGC SoundboardTM -/-/- C004 861 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard 90/90/90 C005 861 x 16mm BGC Fireboard -/-/- C0018 862 x 16mm BGC Fireboard 90/90/90 C006 873 x 16mm BGC Fireboard 120/120/120 C007 87

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER1 x 10mm BGC Ceilingboard -/-/- C010 881 x 13mm BGC Plasterboard -/-/- C011 881 x 6mm BGC DuralinerTM (furring channel at 450mm max centres) -/-/- C012 881 x 9mm BGC DuralinerTM -/-/- C013 892 x 13mm BGC Fireboard 60/60/60 C014 891 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard 90/90/90 C015 892 x 16mm BGC Fireboard 90/90/90 C016 903 x 16mm BGC Fireboard 120/120/120 C017 90

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER1 x 13mm BGC Plasterboard -/-/- C020 911 x 10mm BGC SoundboardTM -/-/- C021 912 x 10mm BGC SoundboardTM -/-/- C022 911 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard 90/90/90 C023 922 x 13mm BGC Fireboard 60/60/60 C024 922 x 16mm BGC Fireboard 90/90/90 C025 92

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER1 x 10mm BGC SoundboardTM -/-/- C030 932 x 10mm BGC SoundboardTM -/-/- C031 931 x 13mm BGC PlasterboardTM -/-/- C032 931 x 13mm BGC SoundboardTM -/-/- C033 942 x 13mm BGC Fireboard 60/60/60 C037 941 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard 90/90/90 C034 942 x 16mm BGC Fireboard 90/90/90 C035 953 x 16mm BGC Fireboard 120/120/120 C036 95

QUICK REFERENCE GUIDE FLOOR / CEILING - TIMBER OR STEEL JOISTS WITH FURRING CHANNELS

QUICK REFERENCE GUIDE FLOOR / CEILING - TIMBER OR STEEL JOISTS WITH FURRING CHANNELS & ACOUSTIC RESILIENT MOUNTS

QUICK REFERENCE GUIDE ROOF/CEILING - TIMBER TRUSSES

Page 10: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

9

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER1 x 10mm BGC Plasterboard -/-/- C040 961 x 10mm BGC SoundboardTM -/-/- C041 961 x 13mm BGC SoundboardTM -/-/- C042 961 x 6mm BGC DuralinerTM (furring channels at 450mm max centres) -/-/- C043 971 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard 90/90/90 C044 972 x 16mm BGC Fireboard 90/90/90 C045 973 x 16mm BGC Fireboard 120/120/120 C046 98

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER1 x 10mm BGC SoundboardTM -/-/- C050 992 x 10mm BGC SoundboardTM -/-/- C051 991 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard 90/90/90 C052 992 x 16mm BGC Fireboard 90/90/90 C053 1003 x 16mm BGC Fireboard 120/120/120 C054 100

LINING FRL SYSTEM NUMBER PAGE NUMBER1 x 13mm BGC Fireboard 30/-/- CB01 103 2 x 13mm BGC Fireboard 60/-/- CB02 103 2 x 16mm BGC Fireboard 90/-/- CB03 103 3 x 13mm BGC Fireboard 90/-/- CB04 103 3 x 16mm BGC Fireboard 120/-/- CB05 103 4 x 16mm BGC Fireboard 180/-/- CB06 103 1 x 13mm BGC Fireboard 30/-/- CB07 104 3 x 13mm BGC Fireboard 60/-/- CB08 104 2 x 16mm BGC Fireboard 90/-/- CB09 104 3 x 16mm BGC Fireboard 120/-/- CB10 104 4 x 16mm BGC Fireboard 180/-/- CB11 104

QUICK REFERENCE GUIDEROOF/CEILING - TIMBER TRUSSES WITH FURRING CHANNELS

QUICK REFERENCE GUIDE ROOF/CEILING - TIMBER TRUSSES WITH FURRING CHANNELS & RESILIENT MOUNTS

QUICK REFERENCE GUIDECOLUMNS & BEAMS

Page 11: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

10B

GC

FIRE & A

CO

US

TIC / M

AR

CH

2013

600mmStud Depth

70mm

90mm

120mm

STRUCTURE OF WALLS & CEILINGS

STRUCTURE

STEEL FRAME DESIGNAS 1170, Structural design actions – General principles defines the loads that steel framed walls are subjected to. Steel framed wall and ceiling systems must be designed according to the relevant standard:

• AS 4100, Steel Structures• AS/NZS 4600, Cold Formed Steel Structures• AS 3623, Domestic Metal Framing• AS/NZS 2785, Suspended Ceilings.

INTERIOR WALLS AND CEILINGSAll interior wall systems and wall height tables published in this Guide comply with the relevant section of BCA Specification C1.8.

• Height tables for non-fire rated walls have been calculated by Rondo Building Services.

As a minimum, all interior wall systems published in this Guide comply with the deflection under Uniformly Distributed Load (UDL) requirements from BCA Specification C1.8. That is, the allowable deflection under a static pressure of 0.25kPa must be less than either:

• Wall height ÷ 240, or• 30mm.

Some applications have additional requirements such as the walls of shafts and fire isolated exits. Unusually strong wind loading conditions such as those experienced in tall buildings may require interior walls and ceilings to be designed to higher pressures than the standard 0.25kPa. (Refer to BCA)

• Ensure fasteners used to fix top and bottom track are appropriate for the Uniform Distributed Loads (UDL) on walls.• At 600mm fastener centres and a UDL of 0.25kPa, the fasteners must withstand a shear load of 0.75kN.• At 600mm fastener centres and a UDL of 0.35kPa, the fasteners must withstand a shear load of 1.1kN.

EXTERIOR WALLS AND CEILINGSFrame design of exterior wall systems must consider:

• Local environmental loading conditions (Refer to AS 1170, Structural Design Actions – General Principles)• Applied vertical load on the studs.

CONTROL JOINTSControl joints allow for any building movement resulting from influences such as moisture migration, loading, structural movement and foundation settlement. Cracks in plasterboard and plasterboard joints can be eliminated by using control joints and the correct installation techniques. Control joints must be installed in plasterboard walls and ceilings at:

• Maximum 12 metre intervals• Control joints in the structure• Any change in the substrate material.

Distance between control joints may need to be reduced to less than 12 metres due to conditions such as large temperature or humidity variations.

3.13.43.43.73.63.94.04.44.44.84.64.85.45.85.96.06.06.0

3.43.73.84.13.94.34.44.84.95.25.15.45.85.96.06.06.06.0

TIMBER STUD HEIGHTS

Noggings in timber stud walls must be spaced at 1350mm max centres and must not protrude past the wall framing surface

Timber Grade

F5

F8

F11

F5

F8

F11

F5

F8

F11

SCREW FIXINGS FOR SOFT WOOD TIMBER AND LIGHTWEIGHT STEEL FRAMING

Framing

Soft Wood Timber

Lightweight Steel up to 0.8mm thickLightweight Steel from 0.8mm to 1.6mm thick

Fireboard Thickness13mm16mm13mm16mm13mm16mm

Screw TypeNo.6 Type ‘W’No.6 Type ‘W’

No.6 Type ‘S’ Needle PointNo.6 Type ‘S’ Needle Point

No.6 Type ‘D’ Drill PointNo.6 Type ‘D’ Drill Point

Screw Length

Stud spacing

Max Wall Height (m)450mm

1st Layer32mm45mm25mm30mm32mm32mm

Stud Thickness 35mm45mm35mm45mm35mm45mm35mm45mm35mm45mm35mm45mm35mm45mm35mm45mm35mm45mm

2nd Layer50mm65mm45mm45mm45mm45mm

3rd Layer65mm75mm50mm65mm65mm65mm

Page 12: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

11STEEL STUD HEIGHTS -

NON LOAD BEARING WALLS

Table 1: 0.25kPa - NON LOAD BEARING WALLS

Table 2: 0.35kPa - NON LOAD BEARING WALLS

Table 3: NOGGING REQUIREMENTS Table 4: WALL HEIGHT LIMITS BASED ON WALL LININGS

WALL FRAME AND LINING CONFIGURATION

WALL FRAME AND LINING CONFIGURATION

LINING CONFIGURATION

600mm CENTRES LINED BOTH SIDES

600mm CENTRES LINED BOTH SIDES

LINED BOTH SIDES

600mm CENTRES ONE SIDE

600mm CENTRES ONE SIDE

LINED ONE SIDE

STAGGERED STUDS

STAGGERED STUDS

STAGGERED STUDS

BOXEDSTAGGERED STUDS

BOXEDSTAGGERED STUDS

STUD SIZE

BMT

LININGS (mm)

10

13

16

(-/180/180)

10

13

16

10

10

STUD SIZE

BMT

LININGS (mm)

10

13

16

(-/180/180)

10

13

16

10

10

0 - 4400

4400 - 8800

0 - 3000

3000 - 6000

6000 - 8000

All

WALL HEIGHT

0

1

1

2

3

0

NO. OF NOGGINGS

MAXIMUM WALL HEIGHT (mm)

MAXIMUM WALL HEIGHT (mm)

51

51

0.5 0.75

0.5 0.75

2770 2910

3200 3320

3380 3520

2310 2620

2310 2620

2310 2620

2420 2550

2810 2920

3000 3120

2070 2340

2070 2340

2070 2340

*6600 *7230

7030 7530

7220 7650

5300 *6800

5300 6800

5290 6800

0.75 1.15

0.75 1.15

0.5 0.75 1.15

0.5 0.75 1.15

3330 3920 4160

3720 4210 4420

3910 4340 4510

2720 3130 3520

2720 3240 3570

2750 3270 3590

2230 2740 3300

2710 3360 4160

2930 3480 3700

3290 3740 3930

3450 3830 3990

2430 2800 3150

2430 2880 3170

2430 2900 3180

2020 2470 2960

2490 3040 3710

3710 4420 4650

4140 5010 5220

4300 5250 5420

3230 3590 4060

3260 3830 4060

3260 3880 4060

4550 4830 5110

4950 5500 5750

5190 5710 5930

3740 4160 4710

3740 4210 4710

3740 4220 4710

0.55 0.75 1.15

0.55 0.75 1.15

0.55 0.75 1.15

0.55 0.75 1.15

150

150

64

64

76

76

92

92

Notes to Tables: Information provided by Rondo Building Services and as such the performances detailed are limited to the Rondo range of products Deflection limited to the lesser of H/240 or 30mm, in accordance with the BCA Specification C1.8 All walls are non load bearing, except for self weight Table 1 loadings: Pultimate = 0.375kPa, Pservice = 0.25kPa Table 2 loadings: Pultimate = 0.525kPa, Pservice = 0.35kPa All loadings in accordance with AS1170:2002 Walls analysed in accordance with AS/NZS4600 Noggings are to be installed as per Table 3 Staggered stud walls have been checked based on zero noggings, and assumed 92mm tracks Tables have been prepared by Rondo Building Services Pty Ltd The design pressures are not suitable for external wall applications The wall heights assume the stud and track sections are of the same, or similar, gauge Wall heights do not consider connection capacity, which should be checked as per Table 4 *Green highlights indicate wall height may be limited by plasterboard linings

LINING CONFIGURATION

LINED BOTH SIDES

LINED ONE SIDE

STAGGERED STUDS

1 x 10mm

1 x 13mm

1 x 16mm

0.50/0.55BMT

1 x 10mm

1 x 13mm

1 x 16mm

1 x 10mm

WALL HEIGHT

5330

8000

12000

5330

5330

8000

10000

5330

3800

5710

8570

3800

3800

5710

7140

3800

MAX WALL HEIGHTS0.25kPa 0.35kPa

3260 *3880 *4090

3650 4420 4600

3790 4610 4770

2890 3210 3630

2890 3380 3630

2890 3420 3630

*4030 *4220 *4480

4400 4840 5060

4610 5010 5200

3340 3720 *4210

3340 3720 4210

3340 3720 4210

*5840 *6420

*6250 *6780

6410 6910

*4790 *6210

4790 *6210

4780 6210

Page 13: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

12

ENVIRONMENTALINFORMATION

BGC Plasterboard shares the general community concern for the environment and seeks to reduce its environmental footprint in all aspects of its operations.

Natural gypsum, the principal ingredient of BGC’s plasterboard products is mined locally at Cape Cuvier, Western Australia, which is renowned for having some of the highest purity gypsum in the world.

BGC Plasterboard has set prudent environmental targets for waste minimisation and energy and water use, and is an active participant in environmental reporting through the Energy Efficiency, Waterwise and Emissions reporting programs.

Through strict quality control systems, productionwaste is minimised and wastage is recycled back into new plasterboard.

GOOD ENVIRONMENTAL CHOICE AUSTRALIAGood Environmental Choice Australia is an environmental labelling program which aims to provide consumers with the knowledge that the product they are purchasing has met certain environmental performance standards which have been developed and assessed in line with International labelling standards.

Scientifically recognised benchmarks for environmental performance have been developed against which products and services are assessed and evaluated to determine whether the product or service should be awarded the Good Environmental Choice Label.

All BGC Plasterboard products have been certified by GECA which means that the products and their manufacturing environment have been evaluated and deemed to comply with the strict guidelines set by GECA.

GECA certification is recognised by the Green Building Council of Australia and may assist in achieving up to 3 Green Star points.

BGC-2011GECA 04-2011v2-PANEL BOARDS

PRODUCT

PLASTERBOARD

CEILINGBOARD

WATER RESISTANT BOARD

SOUNDBOARDTM

FIREBOARD

WATER RESISTANT

FIREBOARD

IMPACTBOARD

CURVEBOARDTM

APPLICATION

• Interior Wall lining system• Suitable for residential & commercial applications• Cost Effective• Ready for decoration• Quick and simple to install• Excellent acoustic performance

• Interior ceiling lining system• Suitable for residential and commercial applications• Cost effective• Quick and simple to install

• Specifically designed for wet areas• Has a low absorption core• Light blue face for ease of identification• Quick and simple to install

• Eliminates or greatly reduces unwanted noise travelling between rooms• Has a higher density core than standard plasterboard• Is ideal for upgrading the acoustic performance of existing walls or ceilings• Is lightweight and easy to install• Installation and handling is similar to that of standard board

• Higher resistance to fire than standard plasterboard• Suitable for interior walls and ceilings• Suitable for fire isolated exits and public corridors• Quick and simple to install • Has a light pink face for ease of identification

• Designed for wet areas where FRL is required• Ideal in partitioning situations• Can be used in ceilings if required• Quick and simple to install

• Specifically designed for high impact areas• Suitable for residential & commercial applications• High resistance to soft body impact• Reduced indentations from hard body impact• Equivalent acoustic performance to BGC Soundboard• Stronger than standard 13mm plasterboard• Same installation as standard plasterboard• Easy to join and finish• Easy to repair

• Provides design flexibility and freedom• Enables construction of contoured walls or ceilings• Allows bending to small radii• Has recessed edges on long edges to provide a continuous surface once flushed• Saves time and money on installation requiring curved surfaces• Lightweight and easy to install• Can be easily applied to timber or light-steel framing• Can be easily finished in a number of finishes

Page 14: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

13

BOUNDARY/EXTERIOR WALLSCertain BGC Fibre Cement products when used in conjunction with 16mm Wet Area Fireboard can achieve both 60/60/60 and 90/90/90 FRL (Fire Resistance Level) fire ratings from the outside as required by the BCA.

Where an exterior wall is required to achieve 60/60/60 FRL from the outside, 1 layer of 16mm Wet Area Fireboard installed with certain BGC Fibre Cement products over the Wet Area Fireboard will meet minimum BCA requirements.

Similarly 2 layers of 16mm Wet Area Fireboard used in conjunction with certain BGC Fibre Cement products will achieve 90/90/90 from the outside.

There are 6 BGC Fibre Cement products that can be used in conjunction with 16mm Wet Area Fireboard to achieve the fire ratings required for boundary/exterior walls. These are:

• 7.5mm DuratexTM

• 9.0mm DuragridTM

• 9.0mm DuracomTM

• 9.0mm DurascapeTM

• 9.0mm DuragrooveTM

• 14.0mm NulineTM Plus

NOTE: All exterior walls must have sarking beneath the BGC Fibre Cement products. No adhesives are to be used when installing Wet Area Fireboard and the BGC Fibre Cement products. Nails or screws must be used.

BUSHFIRE INFORMATIONAS3959:2009 sets out a series of Bushfire threat levels to buildings described as BAL (Bushfire Attack Levels) as follows:

BAL-Low, BAL-12.5, BAL-19, BAL-29, BAL-40 or BAL-FZ (Flamezone).

BGC Fibre Cement and BGC Plasterboard products are eminently suited for both bushfire and boundary wall applications in residential and multi residential buildings when used correctly.

The chart on the next pages shows the different BAL levels that different BGC Fibre Cement and BGC Plasterboard products can achieve if installed correctly.

For detailed Fire and Acoustic results as well as fixing sketches for different products, please see the Exterior Wall pages in the Fire and Acoustic Data section of this guide on pages 75-82.

EXTERIOR WALLS/BUSHFIRE INFORMATION

Page 15: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

BAL 12.5DurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mm

DuracomTM 12.0mmDuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mm

APPLICATIONS

MATERIALS TO ENCLOSE SUBFLOOR SPACES TO BUILDINGS

EXTERIOR WALLS (PARTS LESS THAN

400MM FROM GROUND OR NEAR

HORIZONTAL SURFACE

(<18 ̊TO HORIZONTAL) AND >110MM IN

WIDTH FROM WALL

EXTERIOR WALLS (OTHER)

EAVES LINING

FASCIAS AND BARGEBOARDS

BAL 40 DuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 9.0mmNulineTM Plus 14.0mmDurascapeTM 9.0mmDuragrooveTM 9.0mm

DuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 9.0mm

NulineTM Plus 14.0mmDurascapeTM 9.0mmDuragrooveTM 9.0mm

DuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 9.0mm

NulineTM Plus 14.0mmDurascapeTM 9.0mmDuragrooveTM 9.0mm

DurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmNulineTM Plus 14.0mmDurascapeTM 9.0mmDuragrooveTM 9.0mm

BUSHFIREMATRIX

BAL 29DurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmNulineTM Plus 14.0mmDurascapeTM 9.0mmDuragrooveTM 9.0mm

DurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmNulineTM Plus 14.0mmDurascapeTM 9.0mmDuragrooveTM 9.0mm

DurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mm

BAL FZ>10m

BGC system - T051Exposed side

7.5mm DuratexTM or 9mm DuragridTM or 9mm/12mm

DuracomTM or 9mm DurascapeTM or 9mm

DuragrooveTM or 14mm NulineTM Plus

16mm Wet Area FireboardUnexposed Side

10mm Plasterboard

BGC system - T051Exposed side

7.5mm DuratexTM or 9mm DuragridTM or 9mm/12mm

DuracomTM or 9mm DurascapeTM or 9mm

DuragrooveTM or 14mm NulineTM Plus

16mm Wet Area FireboardUnexposed Side

10mm Plasterboard

BAL 19 DurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mm

DuracomTM 12.0mmDuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mm

BAL FZ <10m

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

14

Page 16: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

BAL 12.5DurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheet TM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 4.5mm

(over 400mm)DurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mm

APPLICATIONSGABLES (PARTS

LESS THAT 400MM FROM GROUND OR NEAR HORIZONTAL SURFACE (<18˚ TO HORIZONTAL) AND >110MM IN WIDTH

FROM WALL

GABLES (OTHER)

MATERIALS TO ENCLOSE

SUBFLOOR SPACES OF VERANDAS, DECKS STEPS,

RAMPS AND LANDINGS

BAL 40 DuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 9.0mmNulineTM Plus 14.0mmDurascapeTM 9.0mmDuragrooveTM 9.0mm

DuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 9.0mmNulineTM Plus 14.0mmDurascapeTM 9.0mmDuragrooveTM 9.0mm

DuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 9.0mmNulineTM Plus 14.0mmDurascapeTM 9.0mmDuragrooveTM 9.0mm

BAL 29DurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmNulineTM Plus 14.0mmDurascapeTM 9.0mmDuragrooveTM 9.0mm

DurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mm

BAL FZ>10mBAL 19 DurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 4.5mmDurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mmDurasheetTM 4.5mm

(over 400mm)DurasheetTM 6.0mmDuracomTM 9.0mmDuracomTM 12.0mm

DuratexTM 7.5mmDuratexTM 9.0mm

DuraplankTM 7.5mmDurascapeTM 9.0mmDuragrooveTM 9.0mmNulineTM Plus 14.0mm

BAL FZ <10m

01 / GEN

ERA

L INFO

RM

ATION

15BUSHFIRE

MATRIX

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

Page 17: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

01 / GEN

ERA

L INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

16

Page 18: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

SOUND INSULATIONEvery partition has a sound insulation rating.A very basic partition may have a sound insulation rating of approximately Rw30. A cinema partition on the other hand may have a rating of around Rw70.

The Rw value is the sound insulation rating, for airborne sound. STC is another sound insulation rating. However STC is no longer in common use in Australia.

A higher Rw rating means a better partition for sound insulation. Airborne sound insulation ratings can range from as low as Rw 10 -15 up to values of Rw 75 and greater. Examples of Rw ratings for different types of partitions are shown below.

Sometimes the Rw value includes a Ctr rating, Rw + Ctr. Ctr is a sound insulation rating for low-frequency noise, like trucks and stereo subwoofers.

For example, the Rw40 partition below has a Ctr rating of -10.

Here, the combined sound insulation rating is Rw + Ctr 30.

Ctr is a negative number and values typically range from about -4 to about -12. The Ctr rating depends on the mass of the partition. A heavier partition will have a smaller Ctr rating.

Choosing the right partition for the job means choosing a partition with the right sound insulation rating. If acoustics is important for your project, we recommend that you contact a qualified acoustic consultant for advice.

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

17ACOUSTICS

BASIC WALL

S001S002

S001

Rw30 Rw70Rw40

Ctr-10

Rw + Ctr30

CINEMA WALL

EG: PARTITIONS SEPARATING:CONSTRUCTION Typical

Rw

30

40

55

65

70

RETAIL TENANCIES

PRIVATE OFFICES

BOARD ROOMS

APARTMENTS

CINEMAS

SC001

S010

SS010

SD023

SD025

02 / AC

OU

STIC

INFO

RM

ATION

Page 19: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

18

ACOUSTICS

BUILDING CODE OF AUSTRALIA: WHO, WHAT, WHY AND HOW?

Who?The Building Code of Australia (BCA) sets acoustic ratings for residential buildings.

What?The BCA sets acoustic ratings for a range of buildings including apartments, hotels, student accommodation and aged-care buildings. The acoustic ratings are for inter-tenancy walls and floors in these buildings.

For example, a wall between two apartments should have an airborne sound insulation rating of Rw+Ctr 50.

Acoustic ratings also apply to entry doors and to services such as ducting and water, soil and waste pipes in the inter-tenancy walls, floors and riser shafts.

Why?The BCA ratings are a minimum acoustic standard for residential buildings. This means that someone living in an apartment can expect a reasonable amount of acoustic privacy from their neighbours.

The BCA ratings are a minimum standard. Apartments and buildings built to a higher quality level generally require walls and floors which exceed BCA standards.

How?Different sound insulation ratings apply to different building elements, depending on the rooms being separated. In some cases ratings include the Ctr. Some cases also include a requirement for the partition to be discontinuous (see below for further discussion).

The specific acoustic requirements from the BCA are detailed in the table below.

BCA INTER-TENANCY AIRBORNE SOUND INSULATION REQUIREMENTS Inter-tenancy partitionWall separating habitable roomssuch as living areas and bedroomsWall separating wet areassuch as bathrooms and laundriesWall separating a wet area or kitchen from a habitable roomWall separating a sole-occupancy unit from a stairway, public corridor, public lobby, etcWall separating a sole-occupancy unit from a plant room or lift shaftFloor separating sole-occupancy unitsFloor separating a sole-occupancy unit from a plant room, lift shaft, stairway, public corridor, public lobby or the likeDoor separating a sole-occupancy unit from a public corridor, public lobby, etcWall, floor or riser separating a duct, soil, waste or water supply pipe from a habitable roomWall floor or riser separating a duct, soil, waste or water supply pipe from a wet area or kitchen

Notes

Wall impact isolation not required

Wall impact isolation not required

Discontinuous construction required

Wall impact isolation not required

Discontinuous construction required

Floor impact isolation criteriaalso apply

Floor impact isolation treatment also required

Sound insulation

Rw + Ctr ≥ 50

Rw + Ctr ≥ 50

Rw + Ctr ≥ 50

Rw ≥ 50

Rw ≥ 50

Rw + Ctr ≥ 50

Rw + Ctr ≥ 50

Rw ≥ 30

Rw + Ctr ≥ 40

Rw + Ctr ≥ 25

Note: BCA Requirements in Queensland and Northern Territory differ from those stated in the table above. BGC recommends further investigation as to BCA requirements in Queensland and Northern Territory.

02 / AC

OU

STIC

INFO

RM

ATION

Page 20: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

02 / AC

OU

STIC

INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

19ACOUSTICS

The figure below shows an example of the type of acoustic performance required to inter-tenancy partitions separating two apartments.

Example of BCA performance requirements for different sections of inter-tenancy partitions

CORRIDOR

Rw + Ctr ≥ 50 discontinuousRw + Ctr ≥ 50Rw ≥ 50

BATHROOM

BATHROOM

BEDROOM

BEDROOMBEDROOM LIVINGLIVING

KITCHENKITCHEN

The acoustic performance of the wall depends on the type of room on each side of the partition. For example, where the wall separates a bedroom or living area in one apartment from a wet area such as

a kitchen or bathroom in another apartment, the partition should be of discontinuous construction.The acoustic performance of a partition between an apartment and a common corridor does not include the Ctr.

APARTMENT INTER-TENANCY WALLWhere acoustic amenity is required to exceed the BCA minimum performance requirement, BGC recommend wall system SD021 for inter-tenancy walls between apartments.

The system has been laboratory tested to Rw 65 and Rw + Ctr 58.

This wall system is classified as a discontinuous construction and exceeds the inter-tenancy partition requirements of the BCA. It will provide a good level of acoustic separation around an apartment and is recommended for all apartment types up to medium-to-high quality.

BGC RECOMMENDEDWALL TYPE

SD021

Page 21: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

02 / AC

OU

STIC

INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

20

ACOUSTICCONCEPTS

INSULATION IN WALL, FLOOR AND ROOF CONSTRUCTIONS Acoustic ratings in this Guide are provided for two different types of polyester insulation: 50mm thick, 9kg/m3 polyester and 75mm thick, 30kg/m3.Fibreglass insulation of the same thickness and mass may be used in lieu of these two types of polyester without changing the acoustic ratings.

ON-SITE PERFORMANCEIn an acoustic laboratory, sound insulation ratings are measured using purpose built rooms which give very accurate, reproducible results. The Rw value is a laboratory result.

Things are not so simple on site. For example, the rating of a wall can be affected by the floor it is mounted on, the overhead ceiling, the side walls and any penetrations and services which run through the wall or floor above. The DnT,w value is an on site result.

The Rw and DnT,w values are similar in concept but are not the same. The difference is the DnT,w accounts for the imperfect testing conditions found on site. As a guide, the DnT,w value of a partition is typically around 5dB lower than the Rw value.

The Ctr correction can be applied to both Rw and DnT,w ratings. For example, the BCA states that walls separating adjacent apartments should have a minimum DnT,w + Ctr 45 rating, when site verificationis being used for assessment purposes.

FLANKINGFlanking transmission means sound transmission around the partition rather than through it.

Flanking transmission can occur when the floor, walls or ceiling around a separating partition have poor sound insulation, which decreases the performance of the separating partition. Flanking transmission is common on site and should be carefully assessed.

IMPACT SOUND AND DISCONTINUITYSo far, we have covered airborne sound which means sound such as voices and audio-speakers which travels through air. Impact sound means sound generated from impact on the partitions and floors of the building.

For example, if someone walks on their tiled floor, a person on the floor beneath will hear the impact sound. Another example is someone closing a kitchen cupboard. If the cupboard is connected to the wall, a person on the other side of the wall will hear the impact sound from the cupboard door. For example,double stud partitions are discontinuous and singlesteel studs partitions are not.

In the BCA some partitions need to provide wall impact isolation. For example, a partition between a kitchen or bathroom in one apartment and a living room or bedroom in another apartment should have a discontinuous construction. This means the partition should include a structural break.

There are a number of resilient acoustic mounts available in the market place. It is critical that a suitable resilient acoustic mount be selected in order for wall, floor or roof construction to achieve the acoustic rating. Good quality resilient acoustic mounts should be selected and loaded appropriately to ensure that static deflection is sufficient to achieve good acoustic performance. A suitable static deflection is typically around 5mm. Rondo and Embelton supply suitable resilient acoustic mounts.

Flanking sound transmission

Impact sound

Page 22: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

QUALITY CONSTRUCTIONS / GENERAL DETAILINGQuality on-site construction is critical to achieve a good level of acoustic performance in any building project. Small gaps and holes can often occur in and around a wall or floor. If these are left untreated they significantly down-rate the acoustic performance. Any gaps and holes must be minimised. Gaps and holes which do occur, including those around services penetrations, should be acoustically sealed to minimise the leakage effect on acoustic performance.

ACOUSTIC RATINGSAcoustic ratings in this Guide have been prepared by Marshall Day Acoustics Pty Ltd. Acoustic ratings have been developed based upon laboratory test data for BGC wall and floor systems, other available laboratory data for comparable constructions and calculations based on theoretical models. Ratings are expected to be accurate to within ± 2.5 Rw.

DISCONTINUOUS CONSTRUCTION e.g. SD019

CONTINUOUS CONSTRUCTION e.g. S001

02 / AC

OU

STIC

INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

21ACOUSTIC

CONCEPTS

S001

SD019

Page 23: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

02 / AC

OU

STIC

INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

22

GLOSSARY OFACOUSTIC TERMS

dB

NOISE

SOUND INSULATION orSOUND REDUCTION

Rw

DnT,w

Ctr

Rw+Ctr

DnT,w+Ctr

FLANKING

STRUCTURE-BORNE TRANSMISSION

Decibel. The unit of sound level.

Unwanted sound.

When sound hits a surface, some of the sound energy travels through the material. ‘Sound insulation or sound reduction’ refers to ability of a material to stop sound travelling through it.

Weighted sound reduction index. A single number rating of the sound insulation performance of a specific building element such as a wall or floor. Rw is measured in a laboratory.

Weighted standardised level difference. A single number rating of the sound level difference between two rooms. DnT,w is typically used to measure on-site sound insulation performance of building elements such as a walls or floors.

The on-site DnT,w value is typically about 5 points less than the laboratory Rw value.

Ctr is a sound insulation adjustment, commonly used with Rw and DnT,w. Ctr adjusts for low frequency noise, such as noise from trucks and subwoofers. Ctr values typically range from about -4 to about -12.

The combined value of Weighted sound reduction index Rw + Spectrum adaptation term Ctr.A single number rating of the sound insulation performance of a building element with the Ctr correction included. Rw+Ctr values are measured in the laboratory and are lower than Rw values.

The combined value of Weighted standardised level difference DnT,w + spectrum adaptation term Ctr.A single number rating of the sound level difference between two rooms with the Ctr correction included. DnT,w+Ctr is used to measure on-site sound insulation performance of building elements such as a walls or floors. DnT,w+Ctr values are lower than DnT,w values.

Transmission of sound energy through paths adjacent to the building element being considered. For example, sound may be transmitted around a wall by travelling up into the ceiling space and then down into the adjacent room.

Transmission of sound energy as vibrations inside the structure of a building.

Page 24: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

03 / FIRE IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201323

BGC FIRE-RESISTANT (FR)PLASTERBOARD PARTITION SYSTEMS

INTRODUCTIONBGC fire-rated systems consist of single or multiple layers of BGC Fireboard sheets, screw-fixed to steel framing and nail or screw fixed to timber stud framing.

BGC Fireboard is manufactured to the requirements of Australian Standards AS/NZS 2588:1998 - “Gypsum plasterboard” and must be installed in accordance with the Australian Standards AS/NZS 2589:2007 Gypsum linings - Application and Finishing.

BGC fire rated systems have been tested according to AS/NZS 3837: 1998 and AS/NZS 1530.4, by NATA accredited testing laboratories.

BGC Fireboard has a light-pink facing liner board and BGC Wet Area Fireboard has a blue/grey facing liner board for easy identification and is available in 13mm and 16mm thicknesses with recessed edges, ready for taping and jointing with proprietary jointing materials.

EARLY FIRE HAZARD INDICESBGC Fireboard complies with the Building Code of Australia (BCA) Material Group Number Classification and Deemed to Satisfy Provisions, as determined by AS/NZS 3837: 1998 tests.

• Material Classification: Group 1. (BCA) Specification A2.4)

• Suitability as Wall and Ceiling Lining In Fire-Isolated Exits, Public Corridors, Specified and Other Areas. (BCA Specification C1.10a Section 3(c) and Table 2: Wall and Ceiling Linings Material Groups Permitted.

• CSIRO BCE Certificate No 482

APPLICATIONBGC Fireboard systems are suitable for industrial, commercial and residential applications, both in the new construction and renovation sectors.

Load bearing, non-load bearing walls and partitions can be clad with single or multiple layers of BGC Fireboard, with or without cavity infill insulation, to achieve the required results for fire resistance: FRL and acoustic properties: RW.

NON-LOAD BEARING WALLSThe maximum wall heights for non-load bearing fire rated walls, in this Installation Guide are for laterally loaded walls of 0.25 kPa and 0.35 kPa, as set out in the Rondo Tables on page 11.

The maximum stud height is based H/240 or 30mm maximum deflection, to comply with BCA 2004 Specification 1.8 Clause 3.4.

LOAD BEARING WALLSLoad bearing walls in this Installation Guide must be designed and constructed in accordance with AS 1684 and AS 1720, for timber construction and AS/NZS 4600 and AS 3623 for light-weight Cold-Formed-Steel (CFS) construction.

Load bearing walls must be designed and constructed to take all loads without any cladding or lining.

INSTALLATIONInstallation is to be in accordance with AS/NZS 2589:2007 Gypsum linings - Application and Finishing and as set out in this manual.

All fire rated plasterboard must be mechanicallyfastener fixed to steel or timber framing. Stud adhesive must not be used.

For multiple layered systems all joints must be staggered and butt joints in the outer layer may be reinforced with laminating screws.

All perimeter gaps and penetrations must be fully sealed with an AS/NZS approved fire rated mastic sealant, to attain the required FRL and RW ratings.

Page 25: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

03 / FIRE IN

FOR

MATIO

N24

FIRE RESISTANCE TERMS AND DEFINITIONS

FIRE RESISTANCE LEVEL (FRL)The nominal grading period, in minutes, that is determined by subjecting a specimen to the standard time temperature curve regime as set out in AS1530.4.

This is to specify—

(a) Structural adequacy(b) Integrity(c) Insulation

These are expressed in that order. Refer to the example below

60/60/60. This indicates that it is a loadbearing system as it has a figure (60) in the first area (Structural adequacy)

-/60/60. This indicates that it is a non loadbearing system as it has no figure (-) in the first area (Structural adequacy)

The definitions as set out in the Standard are below: STRUCTURAL ADEQUACYThe ability of a load-bearing element of construction to support a load when tested in accordance with AS1530.4.

Eg: 60/60/60

INTEGRITYThe ability of an element of construction to resist the passage of flames and hot gases from one space to another, when tested in accordance with AS1530.4.

Eg: 60/60/60

INSULATIONThe ability of an element of construction to maintain a temperature on the surface that is not exposed to the furnace, below the limits specified, when tested in accordance with AS1530.4.

Eg: 60/60/60

This means that during a fire test, the system did not fail for 60 minutes for each of the criteria.

Ensure fasteners used to fix top and bottom track are appropriate for the Uniform Distributed Loads (UDL) on walls.

At 600mm fastener centres and a UDL of 0.25kPa, the fasteners must withstand a shear load of 0.75kN.

At 600mm fastener centres and a UDL of 0.35kPa, the fasteners must withstand a shear load of 1.1kN.

Below is the standard time vs temperature table which is represented in the STANDARD TIME VS TEMPERATURE CURVE.

This shows the rise in temperature vs the associated time.

As indicated, in 5 minutes the temperature in the test facility has risen to 576 degrees Celsius, in 15 minutes 738 degrees Celsius and 90 minutes over 1,000 degrees Celsius and so on.

Where a wall or ceiling is required to meet the various requirements under the BCA it is the job of the Fireboard and the framing to prevent the flames, smoke and temperature from getting through to the other side.

For example, where there is a wall required to achieve a -/120/120 system number SO21 shows 2 layers of 13mm Fireboard both sides of a metal stud. Effectively overall there is 52mm of fire rated plasterboard and framing to stop a peak of over 1,000 degrees of heat reaching through to the other side for a period of 2 hours.

Time Mins 0 5 10 15 30 60 90 120 180 240 360Temp Celsius 20 576 679 738 841 945 1006 1049 1110 1153 1213

VERTICAL - TEMP CELSIUS/ HORIZONTAL - TIME MINS

1400

1200

1000

800

600

400

200

00 100 200 300 400

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

Page 26: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

03 / FIRE IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201325

BGC FIRE-RESISTANT (FR)PLASTERBOARD PARTITION SYSTEMS

CONTROL JOINTSA joint between or within discrete elements of construction, which allows for relative movement of the elements.

Control joints can allow for a degree of building movement which can result from such things as moisture, loads, structural movement and foundation settlement etc. Cracks in plasterboard and plasterboard joints should be eliminated by using control joints and the correct installation techniques. Control joints must be installed in plasterboard walls and ceilings at:

• Maximum 12 metre intervals• Control joints in the structure• Any change in the substrate material• Junctions of dissimilar structural products• When long runs of plasterboard meet at right angle (change of direction)

Distance between control joints may need to be minimised to less than 12 metres due to on site conditions such as humidity or temperature variations or where ever excessive structural movement is likely to occur.

ACCEPTABLE VARIATIONS TO FIRE RATED SYSTEMSFire rated systems must be built according to BGC installation instructions. However, there are some variations allowed that will not degrade the performance of the system:

• Increasing the width of the cavity (between stud walls in a double stud wall system)• Increasing the stud size or the metal thickness• Adding noggings to support fixtures or services• Decreasing stud spacing (increasing amount of studs)• Additional fasteners• Adding non-combustible layers to a system up to a weight of 20kg/m2 and no thicker than 25mm. This includes fibre cement board up to 9mm thick and plasterboard up to 25mm thick. For load bearing walls, the load per stud must include the extra lining.

MODIFICATIONS TO FIRE RATED SYSTEMSFire rated systems may be modified by the installation of the following examples but not limited to these:

• Fire rated inspection hatches• Fire rated power points• Fire rated light fittings• Fire rated doors

It is the responsibility of the manufacturer of additional components in a fire system to ensure that the fire and acoustic properties of the plasterboard system are maintained. Any modification not covered in this manual must be according to the relevant manufacturer’s instructions.

Page 27: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

03 / FIRE IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201326

Page 28: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM SINGLE STUD

FRL

- / - / -

FRL

- / - / -

FRL

- / - / -

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 10mm BGC Plasterboard Side 2 1 x 10mm BGC Plasterboard

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Plasterboard Side 2 1 x 13mm BGC Plasterboard

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 13mm BGC Plasterboard Side 2 1 x 13mm BGC Plasterboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

STUD DEPTH mm

51 64 76 92 150

Rw/Rw+Ctr

30/25 31/25 31/26 32/26 33/27

38/29 39/29 40/30 41/31 43/34

38/29 40/30 40/30 42/31 44/34

71 84 96 112 170

51 64 76 92 150

Rw/Rw+Ctr

33/28 34/28 34/28 35/29 37/31

41/31 42/32 43/32 44/33 46/37

42/31 43/32 44/32 45/34 47/37

77 90 102 118 176

51 64 76 92 150

Rw/Rw+Ctr

38/32 38/32 39/32 40/33 42/34

45/34 46/34 47/37 49/40 49/41

45/34 46/34 48/37 49/40 49/42

90 103 115 131 189

S001

S002

S003

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

27

Page 29: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

28B

GC

FIRE & A

CO

US

TIC / M

AR

CH

2013

STEEL FRAME INTERIOR WALL SYSTEM SINGLE STUD

FRL

- / - / -

FRL

- / - / -

FRL

- / - / -

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 13mm BGC Plasterboard Side 2 2 x 13mm BGC Plasterboard

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 10mm BGC SoundboardTM Side 2 1 x 10mm BGC SoundboardTM

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC SoundboardTM Side 2 1 x 13mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

STUD DEPTH mm

51 64 76 92 150

Rw/Rw+Ctr

41/34 42/33 43/37 44/37 46/38

49/38 50/41 52/43 53/45 55/48

49/38 50/41 53/43 54/46 55/48

103 116 128 144 202

51 64 76 92 150

Rw/Rw+Ctr

33/28 35/29 35/29 36/29 38/31

41/31 42/32 44/33 44/34 47/38

41/31 43/32 44/33 45/34 48/39

71 84 96 112 170

51 64 76 92 150

Rw/Rw+Ctr

36/31 37/31 38/32 39/33 41/34

44/33 45/34 46/37 46/38 48/42

44/33 45/35 46/38 47/38 49/43

77 90 102 118 176

S005

S006

S007

Page 30: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM SINGLE STUD

FRL

- / - / -

FRL

- / - / -

FRL

- / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 10mm BGC SoundboardTM

Side 2 1 x 10mm BGC WR Plasterboard

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 10mm BGC SoundboardTM Side 2 2 x 10mm BGC SoundboardTM

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard Side 2 1 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

STUD DEPTH mm

51 64 76 92 150

Rw/Rw+Ctr

38/32 38/32 39/32 40/33 42/34

44/34 46/34 47/36 48/39 49/41

45/34 47/34 47/36 49/39 49/41

81 94 106 122 180

51 64 76 92 150

Rw/Rw+Ctr

42/34 43/36 44/37 44/37 46/38

50/40 52/41 53/43 54/46 55/48

50/40 52/42 53/44 54/46 55/49

91 104 116 132 190

51 64 76 92 150

Rw/Rw+Ctr

34/29 35/29 36/30 37/31 39/33

42/32 43/32 44/33 45/36 47/40

42/32 44/33 44/34 46/37 48/41

77 90 102 118 176

PREVIOUSLY BGC001

S009

S010

S011

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

29

Page 31: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

30B

GC

FIRE & A

CO

US

TIC / M

AR

CH

2013

STEEL FRAME INTERIOR WALL SYSTEM SINGLE STUD

FRL

- / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard 1 x 10mm BGC Plasterboard Side 2 1 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 51 64 76 92 150

Rw/Rw+Ctr

38/33 39/33 40/33 41/34 43/35

46/34 47/36 48/39 49/39 50/42

46/34 48/36 49/39 49/39 50/42

87 100 112 128 186

S012

FRL

- / 60 / 60

60 / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Fireboard Side 2 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 51 64 76 92 150

Rw/Rw+Ctr

36/31 37/31 38/32 39/33 41/34

44/33 45/34 46/37 46/38 48/42

44/33 45/35 46/38 47/38 49/43

83 96 108 124 182

PREVIOUSLY BGC003 S019

FRL

- / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard Side 2 2 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 51 64 76 92 150

Rw/Rw+Ctr

39/33 40/33 40/34 41/35 43/37

47/35 48/38 49/41 50/41 52/44

48/35 49/39 49/41 51/42 52/45

90 103 115 131 189

S018

Page 32: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM SINGLE STUD

FRL

- / 120 / 120

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 13mm BGC Fireboard Side 2 2 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 51 64 76 92 150

Rw/Rw+Ctr

43/36 44/38 45/39 46/39 48/41

50/42 52/43 54/46 54/47 56/49

50/42 52/44 54/47 55/48 56/49

103 116 128 144 202

PREVIOUSLY BGC002 S021

FRL

-/120/120

STEEL STUDS AT 600mm MAX CENTRES Side 1 3 x 13mm BGC Fireboard Side 2 3 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 51 64 76 92 150

Rw/Rw+Ctr

47/41 48/41 49/42 50/43 53/45

57/49 57/50 58/51 58/52 59/54

57/49 58/51 58/52 58/53 59/55

129 142 154 170 228

FRL

- / 120 / 120

90 / 90 / 90

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm BGC Fireboard Side 2 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 51 64 76 92 150

Rw/Rw+Ctr

45/38 47/40 47/39 48/40 50/42

53/43 54/46 55/47 55/48 56/49

54/44 55/47 55/47 56/49 56/49

115 128 140 156 214

PREVIOUSLY BGC004 S023

S025

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

31

Page 33: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

32B

GC

FIRE & A

CO

US

TIC / M

AR

CH

2013

STEEL FRAME INTERIOR WALL SYSTEM SINGLE STUD

FRL

- / 180 / 180

FRL

- / - / -

FRL

- / - / -

STEEL STUDS AT 600mm MAX CENTRES Side 1 3 x 16mm BGC Fireboard Side 2 3 x 16mm BGC Fireboard

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 6mm BGC DuralinerTM Side 2 1 x 6mm BGC DuralinerTM

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 9mm BGC DuralinerTM Side 2 1 x 9mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

STUD DEPTH mm

51 64 76 92 150

Rw/Rw+Ctr

50/43 51/44 51/44 52/45 54/46

58/49 58/51 58/53 59/54 59/56

58/49 58/52 59/54 59/54 59/56

147 160 172 188 246

51 64 76 92 150

Rw/Rw+Ctr

32/26 33/26 33/26 33/27 35/28

41/31 41/31 43/32 44/32 46/35

41/31 42/31 43/32 44/32 46/35

63 76 88 104 162

51 64 76 92 150

Rw/Rw+Ctr

39/32 40/33 41/33 41/34 42/34

45/33 47/35 48/37 49/38 49/42

46/34 47/35 49/37 49/38 49/43

69 82 94 110 168

S026

S027

S028

Page 34: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM SINGLE STUD

FRL

- / - / -

FRL

- / - / -

FRL

- / - / -

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 12mm BGC DuralinerTM Side 2 1 x 12mm BGC DuralinerTM

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 10mm BGC SoundboardTM Side 2 1 x 6mm BGC DuralinerTM

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Plasterboard Side 2 1 x 6mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

STUD DEPTH mm

51 64 76 92 150

Rw/Rw+Ctr

40/33 40/33 41/35 43/36 44/37

48/36 49/40 49/40 52/44 54/47

48/37 49/40 49/40 53/44 54/47

75 88 100 116 174

51 64 76 92 150

Rw/Rw+Ctr

34/28 35/29 35/28 36/29 38/31

41/31 42/32 44/32 44/33 46/36

42/31 43/32 44/32 45/33 47/37

67 80 92 108 166

51 64 76 92 150

Rw/Rw+Ctr

34/28 35/28 35/28 36/29 38/31

41/31 42/31 43/32 44/33 46/36

41/31 42/32 44/32 45/33 47/37

70 83 95 111 169

S029

S031

S033

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

33

Page 35: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

34

STEEL FRAME INTERIOR WALL SYSTEM SINGLE STUD

FRL

- / - / -

FRL

- / - / -

FRL

- / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Plasterboard Side 2 1 x 9mm BGC DuralinerTM

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard Side 2 1 x 6mm BGC DuralinerTM

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Fireboard (against studs) 1 x 9mm BGC DuralinerTM Side 2 1 x 16mm BGC Fireboard (against studs) 1 x 9mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

STUD DEPTH mm

51 64 76 92 150

Rw/Rw+Ctr

36/30 36/30 37/31 38/31 41/34

42/32 44/33 45/34 46/36 49/40

43/32 45/33 46/34 47/37 49/40

73 86 98 114 172

51 64 76 92 150

Rw/Rw+Ctr

34/28 35/28 35/28 36/29 38/31

41/31 43/32 45/33 46/35 49/39

42/31 44/33 45/33 46/35 49/40

70 83 95 111 169

51 64 76 92 150

Rw/Rw+Ctr

45/38 47/40 47/39 48/40 50/42

53/43 54/46 55/47 55/48 56/49

54/44 55/47 55/47 56/49 56/49

73 86 98 114 172

S034

S035

S041

Page 36: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM SINGLE STUD

FRL

120 / 120 / 120

FRL

- / 180 / 180

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 9mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard Side 2 1 x 9mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm Wet Area Fireboard Side 2 2 x 16mm Wet Area Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

51 64 76 92 150

Rw/Rw+Ctr

45/38 47/40 47/39 48/40 50/42

53/43 54/46 55/47 55/48 56/49

54/44 55/47 55/47 56/49 56/49

73 86 98 114 172

51 64 76 92 150

Rw/Rw+Ctr

45/38 47/40 47/39 48/40 50/42

53/43 54/46 55/47 55/48 56/49

54/44 55/47 55/47 56/49 56/49

73 86 98 114 172

PREVIOUSLY BGC DL001 S043

S044

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

35

Page 37: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

36

STEEL FRAME INTERIOR WALL SYSTEM SINGLE STUD

FRL

- / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 Side 2 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 51 64 76 92 150

Rw/Rw+Ctr

35/32 - - - -

- - - - -

- - - - -

83 96 108 124 182

FRL

- / 120 / 120

120 / 120 / 120

STEEL STUDS AT 600mm MAX CENTRES Side 1 Side 2 3 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 51 64 76 92 150

Rw/Rw+Ctr

38/36 - - - -

- - - - -

- - - - -

99 112 124 140 198

S046

FRL

- / 120 / 120

120 / 120 / 120

STEEL STUDS AT 600mm MAX CENTRES Side 1 Side 2 3 x 16mm BGC Wet Area Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 51 64 76 92 150

Rw/Rw+Ctr

38/36 - - - -

- - - - -

- - - - -

99 112 124 140 198

S045

S048

Page 38: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM STAGGERED STUD

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 10mm BGC Plasterboard Side 2 1 x 10mm BGC Plasterboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

33/27 33/27 34/28

42/32 43/33 46/36

42/32 44/33 47/37

96 112 170

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Plasterboard Side 2 1 x 13mm BGC Plasterboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

36/30 37/31 39/33

46/34 47/36 49/38

46/34 47/36 49/38

102 118 176

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 10mm BGC SoundboardTM Side 2 1 x 10mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

36/30 37/30 39/32

46/35 47/36 49/38

47/35 48/36 49/38

96 112 170

SS001

SS002

SS006

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

37

Page 39: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

38B

GC

FIRE & A

CO

US

TIC / M

AR

CH

2013

STEEL FRAME INTERIOR WALL SYSTEM STAGGERED STUD

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 10mm BGC SoundboardTM Side 2 2 x 10mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

46/39 46/39 49/41

54/44 56/46 58/49

55/44 57/47 59/50

116 132 190

SS010

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC SoundboardTM Side 2 1 x 13mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

38/32 39/33 41/34

48/38 49/39 52/44

49/38 50/39 53/45

102 118 176

SS007

FRL

- / 60 / 60

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard Side 2 1 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

38/32 39/33 41/35

47/36 49/38 50/42

48/36 49/38 51/42

102 118 176

SS011

Page 40: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM STAGGERED STUD

FRL

- / 60 / 60

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Fireboard Side 2 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

38/32 39/33 41/34

48/38 49/39 52/44

49/38 50/39 53/45

108 124 182

SS019

FRL

- / 60 / 60

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 13mm BGC Fireboard Side 2 1 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

41/35 43/37 45/38

52/43 53/43 55/47

53/43 54/43 57/48

115 131 189

SS018

FRL

- / 60 / 60

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard 1 x 13mm BGC Plasterboard Side 2 1 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

40/33 42/36 44/37

50/42 52/42 55/46

50/42 54/42 56/47

115 131 189

SS014

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

39

Page 41: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

40

FRL

- / 60 / 60

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Fireboard 1 x 13mm BGC Fireboard Side 2 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

43/36 44/38 46/39

53/42 54/45 56/48

54/43 55/45 57/49

121 137 195

SS020

FRL

- / 120 / 120

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 13mm BGC Fireboard Side 2 2 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

46/40 47/40 50/42

56/46 57/48 59/52

57/46 58/49 60/52

128 144 202

FRL

- / 120 / 120

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm BGC Fireboard Side 2 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

47/40 48/41 51/43

57/48 58/49 61/54

58/49 59/50 61/54

140 156 214

SS021

SS023

STEEL FRAME INTERIOR WALL SYSTEM STAGGERED STUD

Page 42: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM STAGGERED STUD

FRL

- / 180 / 180

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 3 x 16mm BGC Fireboard Side 2 3 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

50/42 51/43 54/45

60/52 61/53 62/56

61/53 61/54 62/57

172 188 246

SS026

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 9mm BGC DuralinerTM

Side 2 1 x 9mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

39/31 39/32 41/33

48/37 49/37 52/42

49/37 50/38 54/43

94 110 168

SS028

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 10mm BGC SoundboardTM Side 2 1 x 6mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

39/32 39/32 41/33

47/36 49/39 52/43

49/37 50/39 54/43

102 118 176

SS032

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

41

Page 43: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

42

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard Side 2 1 x 6mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

36/29 37/30 39/32

46/34 47/36 49/38

47/34 48/36 49/38

95 111 169

SS035

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Plasterboard Side 2 1 x 6mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

35/28 36/29 38/31

45/34 46/35 49/38

46/34 47/35 49/38

95 111 169

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Plasterboard Side 2 1 x 9mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

38/32 39/32 42/35

47/35 49/38 50/42

48/36 49/38 51/40

98 114 172

SS033

SS034

STEEL FRAME INTERIOR WALL SYSTEM STAGGERED STUD

Page 44: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM STAGGERED STUD

FRL

- / 60 / 60

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Fireboard (against studs) 1 x 9mm BGC DuralinerTM Side 2 1 x 16mm BGC Fireboard (against studs) 1 x 9mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

47/39 48/40 51/43

57/47 58/49 60/52

58/48 59/50 61/53

98 114 172

FRL

120 / 120 / 120

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 9mm BGC DuralinerTM (against studs) 1 x 16mm BGC FireboardSide 2 1 x 9mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

47/39 48/40 51/43

57/47 58/49 60/52

58/48 59/50 61/53

98 114 172

PREVIOUSLY BGC DL001

SS041

SS043

FRL

- / - / -

STAGGERED STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 9mm BGC DuralinerTM

Side 2 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY WIDTH mm 76 92 150

Rw/Rw+Ctr

39/31 39/32 41/33

48/37 49/37 52/42

49/38 50/38 53/43

101 117 175

SS036

04 / STEEL FR

AM

E INFO

RM

ATION

43B

GC

FIRE & A

CO

US

TIC / M

AR

CH

2013

Page 45: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

44B

GC

FIRE & A

CO

US

TIC / M

AR

CH

2013

STEEL FRAME INTERIOR WALL SYSTEM DOUBLE STUD

FRL

- / - / -

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 10mm BGC Plasterboard Side 2 1 x 10mm BGC Plasterboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 34/28 34/28 35/28 36/28 44/33 45/35 46/37 46/39 46/35 47/37 48/39 48/41 47/36 49/38 49/40 49/41 49/36 49/38 49/39 50/42 168 192 224 340

FRL

- / - / -

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 10mm BGC SoundboardTM Side 2 1 x 10mm BGC SoundboardTM

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 39/32 39/33 40/33 42/33 51/41 52/43 52/44 52/46 53/43 54/45 55/46 55/49 54/43 55/45 56/46 56/49 56/44 57/46 57/47 58/49 168 192 224 340

SD001

SD006

FRL

- / - / -

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Plasterboard Side 2 1 x 13mm BGC Plasterboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 39/33 39/32 40/33 42/34 51/42 52/43 52/44 52/46 53/43 54/44 54/46 55/48 54/43 54/44 55/46 56/48 56/45 57/45 57/47 58/49 174 198 230 346

SD002

Page 46: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM DOUBLE STUD

FRL

- / - / -

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC SoundboardTM Side 2 1 x 13mm BGC SoundboardTM

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320Rw/Rw+Ctr

42/35 42/35 43/36 46/37 54/45 55/47 55/48 56/49 56/45 57/48 57/49 58/49 57/46 57/48 58/49 59/50 59/48 60/49 60/49 61/50 174 198 230 346

FRL

- / 60 / 60

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard Side 2 1 x 13mm BGC Fireboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 40/34 41/34 42/35 43/35 52/43 52/45 53/45 53/48 54/45 54/46 55/47 55/49 55/46 56/47 57/48 57/49 57/46 58/47 58/48 59/49 174 198 230 346

SD011

SD007

FRL

60 / 60 / 60

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Fireboard (against studs) 1 x 10mm BGC Plasterboard Side 2 1 x 16mm BGC Fireboard (against studs) 1 x 10mm BGC Plasterboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 46/39 47/39 48/39 49/40 58/48 59/49 59/49 59/50 60/51 61/52 61/53 62/53 61/51 62/52 62/53 63/54 63/52 65/53 65/54 66/55 200 224 256 372

SD016

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

45

Page 47: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

46

STEEL FRAME INTERIOR WALL SYSTEM DOUBLE STUD

FRL

- / 60 / 60

60 / 60 / 60

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Fireboard Side 2 1 x 16mm BGC Fireboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 41/34 41/34 42/35 45/36 53/45 54/46 54/47 55/49 55/46 56/45 56/49 57/51 56/46 56/47 57/49 58/51 58/48 59/49 60/50 61/52 180 204 236 352

SD019

FRL

- / 120 / 120

90 / 90 / 90

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 13mm BGC Fireboard Side 2 2 x 13mm BGC Fireboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 48/40 49/41 50/41 53/44 60/51 60/52 61/53 61/55 62/52 62/53 63/55 63/57 63/53 64/54 65/56 65/58 65/58 66/58 67/58 68/60 200 224 256 372

SD021

FRL

- / 120 / 120

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm BGC Fireboard Side 2 2 x 16mm BGC Fireboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 48/40 49/41 51/42 54/44 60/52 61/53 61/54 62/56 62/53 63/54 63/55 64/58 63/53 64/54 64/56 65/58 65/58 66/58 66/58 67/60 212 236 268 384

SD023

Page 48: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME INTERIOR WALL SYSTEM DOUBLE STUD

FRL

- / 60 / 60

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 13mm BGC Fireboard Side 2 1 x 13mm BGC Fireboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 45/38 46/39 47/39 49/40 57/48 57/49 58/49 59/50 59/50 59/51 60/52 61/53 60/50 61/51 62/53 63/54 62/54 63/54 64/54 65/55 187 211 243 359

FRL

- / 120 / 120

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 3 x 13mm BGC Fireboard Side 2 3 x 13mm BGC Fireboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 54/45 55/46 56/47 59/49 67/58 67/59 68/60 68/62 68/58 68/59 69/61 69/63 69/58 69/60 70/61 71/64 71/59 71/60 72/62 73/65 226 250 282 398

SD025

SD024

FRL

- / 180 / 180

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 3 x 16mm BGC Fireboard Side 2 3 x 16mm BGC Fireboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 55/46 56/46 57/47 60/49 67/59 68/60 68/61 69/63 69/60 70/61 70/63 71/65 70/60 71/61 71/63 72/65 72/61 73/62 73/63 74/67 244 268 300 416

SD026

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

47

Page 49: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

48

STEEL FRAME INTERIOR WALL SYSTEM DOUBLE STUD

FRL

- / 60 / 60

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard (against studs) 1 x 6mm BGC DuralinerTM Side 2 1 x 13mm BGC Fireboard (against studs) 1 x 6mm BGC DuralinerTM

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 46/38 46/38 48/39 49/39 58/48 58/49 59/49 59/50 60/50 61/51 62/52 62/53 61/50 62/51 63/53 64/54 63/52 64/52 65/53 66/55 186 210 242 358

SD038

FRL

- / - / -

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 6mm BGC DuralinerTM Side 2 1 x 6mm BGC DuralinerTM

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 38/31 39/32 39/32 41/33 50/40 51/41 51/43 52/45 52/41 53/43 53/44 54/46 53/42 54/43 54/45 55/47 55/43 57/45 57/47 58/49 160 184 216 332

FRL

- / - / -

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 9mm BGC DuralinerTM Side 2 1 x 9mm BGC DuralinerTM

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320Rw/Rw+Ctr

42/35 43/35 44/36 46/38 54/44 55/45 55/47 56/49 56/46 57/47 57/48 58/49 57/46 58/48 58/49 59/49 59/48 60/49 60/49 62/50 166 190 222 338

SD027

SD028

Page 50: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

49STEEL FRAME INTERIOR WALL SYSTEM

DOUBLE STUD

FRL

- / 60 / 60

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard Side 2 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 48/40 49/40 50/41 51/42 60/51 60/52 61/53 61/55 62/52 62/53 63/54 63/57 63/53 64/54 65/55 65/58 65/56 66/56 66/56 67/59 192 216 248 364

SD042

FRL

120 / 120 / 120

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 9mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard Side 2 1 x 9mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

CAVITY WIDTH mmCAVITY INFILL

148 172 204 320 Rw/Rw+Ctr 48/39 49/40 50/41 53/43 60/51 61/52 61/53 61/55 62/52 63/53 63/55 64/57 63/52 63/53 64/55 65/58 65/54 66/55 67/57 68/60 198 222 254 370

PREVIOUSLY BGC DL001 SD043

Page 51: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

BGC CINEMA WALL SYSTEM

FRL

120 / 120 / 120

STEEL TOP HATS AT 900mm MAX CENTRES Side 1 3 x 16mm BGC Fireboard Side 2 3 x 16mm BGC Fireboard

2 x Bradford Glasswool 110 (R2.5)2 x Autex AAB32-100

2 x 30kg - 75mm PolyesterWALL THICKNESS

MIN CAVITY mmCAVITY INFILL

SC001

FRL

120 / 120 / 120

STEEL TOP HATS AT 900mm MAX CENTRES Side 1 4 x 16mm BGC Fireboard Side 2 4 x 16mm BGC Fireboard

2 x Bradford Glasswool 110 (R2.5)2 x Autex AAB32-100

2 x 30kg - 75mm PolyesterWALL THICKNESS

MIN CAVITY WIDTH mmCAVITY INFILL

SC002

SYSTEM SET OUT

• Top hat sections (50mm x 35mm x 1.15m) fixed vertically at 900mm max centres to engineers design and supported at the head and the base with tracks• The span of the Top hats between girts shall be nominally 1.9m for single spans and 2.7m for continuous spans. To be confirmed as suitable by the engineer for internal wind pressures.• Steel columns and girts to be engineer specified• Girts to be fixed to vertical steel columns using proprietarty isolation mounts that include a through bolt

PLASTERBOARD FIXINGS

• Layer 1 to Top hat – 30mm bugle head screws at 600mm centres• Layer 2 to Top hat – 45mm bugle head screws at 300mm centres and laminating screws at 300mm centres 200mm from top and bottom• Layer 3 to layer 2 – 38mm laminating screws at 400mm x 400mm grid• Layer 4 to layer 3 – 38mm laminating screws at 400mm x 400mm grid• 2 layers glasswool or polyester insulation. Refer to insulation in system specification• Perimeters to be caulked with fire rated caulking to a depth of 30mm x 10mm wide when used with a backing rod• Vertical control joints to be caulked to a depth of 16mm backed with plaster

375Rw

75/68 75/68 74/67

471

375Rw

79/72 79/72 78/71 503

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

50

Page 52: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

INSTALLATION DETAILSSTEEL STUD

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

51

STEEL FRAME WITH ONE LAYER BGC FIREBOARD - VERTICAL SHEETING

STEEL FRAME WITH ONE LAYER BGC FIREBOARD - HORIZONTAL SHEETING

FASTENER SPACING300mm max. centres300mm max. centres200mm max. centres300mm max. centres

POSITIONCentre of the Board

Recessed EdgesButt Joints

Corners & Openings

FIXING SPECIFICATIONS

1ST LAYER25mm30mm32mm32mm

FRAMINGLightweight Steel up to

0.8mmLightweight Steel 0.8mm

to 1.6mm

FIREBOARD THICKNESS13mm16mm13mm16mm

SCREW TYPENo 6 Type S Needle PointNo 6 Type S Needle Point

No 6 Type D Drill PointNo 6 Type D Drill Point

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING SCREW LENGTH

1ST LAYER25mm30mm32mm32mm

FRAMINGLightweight Steel up to

0.8mmLightweight Steel 0.8mm

to 1.6mm

FIREBOARD THICKNESS13mm16mm13mm16mm

SCREW TYPENo 6 Type S Needle PointNo 6 Type S Needle Point

No 6 Type D Drill PointNo 6 Type D Drill Point

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING SCREW LENGTH

FASTENER SPACING300mm max. centres

At each stud200mm max. centres300mm max. centres

POSITIONCentre of the Board

Recessed EdgesButt Joints

Corners & Openings

FIXING SPECIFICATIONS

Page 53: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

52

INSTALLATION DETAILSSTEEL STUD

STEEL FRAME WITH TWO LAYERS BGC FIREBOARD - VERTICAL SHEETING

STEEL FRAME WITH TWO LAYERS BGC FIREBOARD - FIRST LAYER VERTICAL, SECOND LAYER HORIZONTAL

FASTENER SPACING600mm max. centres600mm max. centres600mm max. centres

LOCATIONCentre of the Board

Recessed EdgesCorners & Openings

FIXING SPECIFICATIONSFIRST LAYER

FASTENER SPACING600mm max. centres600mm max. centres600mm max. centres

LOCATIONCentre of the Board

Recessed EdgesCorners & Openings

FIXING SPECIFICATIONSFIRST LAYER

300mm max. centres300mm max. centres200mm max. centres300mm max. centres

Centre of the BoardRecessed Edges

Butt JointsCorners & Openings

SECOND LAYER

300mm max. centresAt Each Stud

200mm max. centres300mm max. centres

Centre of the BoardRecessed Edges

Butt JointsCorners & Openings

SECOND LAYER

FRAMINGLightweight Steel up to

0.8mmLightweight Steel 0.8mm

to 1.6mm

FIREBOARD THICKNESS13mm16mm13mm16mm

SCREW TYPENo 6 Type S Needle PointNo 6 Type S Needle Point

No 6 Type D Drill PointNo 6 Type D Drill Point

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING SCREW LENGTH1ST LAYER

25mm30mm32mm32mm

2ND LAYER45mm45mm45mm45mm

FRAMINGLightweight Steel up to

0.8mmLightweight Steel 0.8mm

to 1.6mm

FIREBOARD THICKNESS13mm16mm13mm16mm

SCREW TYPENo 6 Type S Needle PointNo 6 Type S Needle Point

No 6 Type D Drill PointNo 6 Type D Drill Point

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING SCREW LENGTH1ST LAYER

25mm30mm32mm32mm

2ND LAYER45mm45mm45mm45mm

Page 54: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

INSTALLATION DETAILSSTEEL STUD

04 / STEEL FR

AM

E INFO

RM

ATION

53

STEEL FRAME WITH THREE LAYERS BGC FIREBOARD - VERTICAL SHEETING

FASTENER SPACING600mm max. centres600mm max. centres600mm max. centres

LOCATIONCentre of the Board

Recessed EdgesCorners & Openings

FIXING SPECIFICATIONS THREE LAYER HORIZONTAL

FIRST LAYER

300mm max. centres600mm max. centres200mm max. centres300mm max. centres

Centre of the BoardRecessed Edges

Butt JointsCorners & Openings

SECOND LAYER

FASTENER SPACING600mm max. centres600mm max. centres600mm max. centres

LOCATIONCentre of the Board

Recessed EdgesCorners & Openings

FIXING SPECIFICATIONS THREE LAYER VERTICAL(Shown)

FIRST LAYER

300mm max. centres300mm max. centres200mm max. centres300mm max. centres

Centre of the BoardRecessed Edges

Butt JointsCorners & Openings

SECOND LAYER

Laminating Screws at400mm max. grid

Centre of the BoardRecessed Edges

Butt JointsCorners & Openings

THIRD LAYER

Laminating Screws at400mm max. grid

Centre of the BoardRecessed Edges

Butt JointsCorners & Openings

THIRD LAYER

FRAMINGLightweight Steel up to

0.8mmLightweight Steel 0.8mm

to 1.6mm

FIREBOARD THICKNESS13mm16mm13mm16mm

SCREW TYPENo 6 Type S Needle PointNo 6 Type S Needle Point

No 6 Type D Drill PointNo 6 Type D Drill Point

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING SCREW LENGTH1ST LAYER

25mm30mm32mm32mm

2ND LAYER45mm45mm45mm45mm

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

Page 55: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

04 / STEEL FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

54

INSTALLATION DETAILSSTEEL STUD

LOAD BEARING WALL 60/60/60

FASTENER SPACING300mm max. centres

At each stud100mm max. centres300mm max. centres

POSITIONCentre of the Board

Recessed EdgesButt Joints

Corners & Openings

FIXING SPECIFICATIONS

Note: Refer to page 10 for screw lengths.

1ST LAYER25mm30mm32mm32mm

FRAMINGLightweight Steel up to

0.8mmLightweight Steel 0.8mm

to 1.6mm

FIREBOARD THICKNESS13mm16mm13mm16mm

SCREW TYPENo 6 Type S Needle PointNo 6 Type S Needle Point

No 6 Type D Drill PointNo 6 Type D Drill Point

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING SCREW LENGTH

Page 56: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME INTERIOR WALL SYSTEMSINGLE STUD

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

55

FRL

- / - / -

FRL

- / - / -

FRL

- / - / -

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 10mm BGC Plasterboard Side 2 1 x 10mm BGC Plasterboard

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 13mm BGC Plasterboard Side 2 1 x 13mm BGC Plasterboard

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 2 x 10mm BGC Plasterboard Side 2 2 x 10mm BGC Plasterboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

STUD DEPTH mm

70 90 120 140

Rw/Rw+Ctr

31/25 32/26 33/27 33/27

37/28 37/28 38/30 39/32

37/28 38/29 39/30 39/32

90 110 140 160

70 90 120 140

Rw/Rw+Ctr

34/28 35/30 36/30 37/31

39/32 40/32 41/35 41/35

40/32 40/32 41/35 41/35

96 116 146 166

70 90 120 140

Rw/Rw+Ctr

39/31 39/33 40/33 41/34

44/36 45/37 45/40 45/40

44/36 45/38 45/40 46/40

90 110 140 160

T001

T002

T004

Page 57: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

56

TIMBER FRAME INTERIOR WALL SYSTEMSINGLE STUD

FRL

- / - / -

FRL

- / - / -

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 2 x 13mm BGC Plasterboard Side 2 2 x 13mm BGC Plasterboard

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 10mm BGC SoundboardTM Side 2 1 x 10mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

70 90 120 140

Rw/Rw+Ctr

41/35 43/37 43/37 44/37

46/41 47/42 47/42 47/43

46/41 47/42 47/43 47/43

122 142 172 192

70 90 120 140

Rw/Rw+Ctr

34/29 35/29 35/29 36/30

39/31 39/32 40/35 40/34

39/31 39/32 40/35 40/35

90 110 140 160

T005

T006

FRL

- / - / -

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 13mm BGC SoundboardTM Side 2 1 x 13mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

36/31 37/31 38/33 38/33

40/34 40/36 40/37 40/37

40/34 41/36 41/37 41/38

96 116 146 166

T007

Page 58: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME INTERIOR WALL SYSTEMSINGLE STUD

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

57

FRL

- / - / -

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 2 x 10mm BGC SoundboardTM Side 2 2 x 10mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

43/37 44/37 44/38 45/39

47/41 48/43 48/44 48/44

47/42 48/43 48/44 48/44

110 130 160 180

FRL

- / 60 / 60

60 / 60 / 60

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard Side 2 1 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

35/30 36/31 37/32 38/33

40/32 41/35 41/36 41/37

40/33 41/35 41/36 42/37

96 116 146 166

PREVIOUSLY BGC 005 T011

T010

FRL

- / - / -

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

35/29 35/29 36/30 37/30

39/31 40/31 41/35 41/34

39/31 40/32 41/35 41/35

90 110 140 160

T008

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 10mm BGC SoundboardTM Side 2 1 x 10mm BGC WR Plasterboard

Page 59: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

05 / TIMB

ER FR

AM

E INFO

RM

ATION

58

TIMBER FRAME INTERIOR WALL SYSTEMSINGLE STUD

FRL

- / 60 / 60

60 / 60 / 60

FRL

- / 120 / 120

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 16mm BGC Fireboard Side 2 1 x 16mm BGC Fireboard

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 2 x 13mm BGC Fireboard Side 2 2 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

70 90 120 140

Rw/Rw+Ctr

36/31 37/31 38/33 38/33

40/34 40/36 40/37 40/37

40/34 41/36 41/37 41/38

102 122 152 172

70 90 120 140

Rw/Rw+Ctr

44/39 44/39 45/40 46/40

48/43 48/44 48/45 48/45

48/43 48/44 48/45 48/45

122 142 172 192

PREVIOUSLY BGC 007 T019

FRL

- / - / -

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 13mm BGC Plasterboard Side 2 1 x 10mm BGC Plasterboard 1 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

37/31 37/31 39/33 39/32

41/33 42/36 43/37 43/38

42/33 42/37 43/38 43/39

106 126 156 176

T015

T021

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

Page 60: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME INTERIOR WALL SYSTEMSINGLE STUD

05 / TIMB

ER FR

AM

E INFO

RM

ATION

59

FRL

60 / 60 / 60

FRL

- / 120 / 120

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 2 x 16mm BGC FireboardSide 2 1 x 16mm BGC Fireboard

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 2 x 16mm BGC Fireboard Side 2 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

STUD DEPTH mm

70 90 120 140

Rw/Rw+Ctr

40/35 41/37 42/37 42/37

44/39 44/40 44/41 44/41

44/39 44/41 44/41 44/41

122 142 172 192

70 90 120 140

Rw/Rw+Ctr

45/40 46/40 46/41 47/42

48/45 48/45 48/45 48/45

48/45 48/45 48/45 48/45

134 154 184 204

T022

FRL

- / 180 / 180

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 3 x 16mm BGC Fireboard Side 2 3 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

134 154 184 204

T026

T023

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

Page 61: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

FRL

- / - / -

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 6mm BGC DuralinerTM Side 2 1 x 6mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

33/26 33/26 34/27 34/27

40/30 41/31 42/34 42/34

40/30 41/31 43/34 43/34

82 102 132 152

T027

05 / TIMB

ER FR

AM

E INFO

RM

ATION

60

TIMBER FRAME INTERIOR WALL SYSTEMSINGLE STUD

FRL

60 / 60 / 60

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

42/36 43/37 44/38 44/38

47/41 47/43 48/43 48/44

47/41 48/43 48/44 48/44

108 128 158 178

PREVIOUSLY BGC DL003 T039

FRL

- / - / -

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 10mm BGC SoundboardTM (against stud) 1 x 6mm BGC DuralinerTM Side 2 1 x 10mm BGC SoundboardTM (against stud) 1 x 6mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

41/34 42/36 43/36 43/36

46/39 47/41 47/42 47/42

46/39 47/41 47/42 47/43

102 122 152 172

T037

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 6mm BGC DuralinerTM (against studs) 1 x 13mm BGC Fireboard Side 2 1 x 6mm BGC DuralinerTM (against studs) 1 x 13mm BGC Fireboard

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

Page 62: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME INTERIOR WALL SYSTEMSINGLE STUD

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

61

FRL

90 / 90 / 90

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard Side 2 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

44/39 45/39 46/40 46/40

48/43 48/44 48/45 48/45

48/43 48/44 48/45 48/45

114 134 164 184

PREVIOUSLY BGC DL004 T042

70 90 120 140

Rw/Rw+Ctr

45/40 46/40 46/41 47/42

48/45 48/45 48/45 48/45

48/45 48/45 48/45 48/45

114 134 164 184

FRL

- / 180 / 180

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 2 x 16mm Wet Area Fireboard Side 2 2 x 16mm Wet Area Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

T044

FRL

- / 60 / 60

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 Side 2 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

35/32 - - -

- - - -

- - - -

102 122 152 172

T046

Page 63: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

62

TIMBER FRAME INTERIOR WALL SYSTEMSINGLE STUD

FRL

- / 90 / 90

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINGS AT 1350mm MAX CENTRES Side 1 Side 2 3 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm 70 90 120 140

Rw/Rw+Ctr

38/36 - - -

- - - -

- - - -

118 138 168 188

T048

Page 64: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME INTERIOR WALL SYSTEMSTAGGERED STUD

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

63

FRL

- / - / -

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

33/27 34/28 35/29

43/34 45/38 45/37

44/34 46/38 46/38

110 140 160

FRL

- / - / -

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 2 x 10mm BGC SoundboardTM Side 2 2 x 10mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

42/35 43/36 44/36

52/45 52/46 53/47

52/45 53/47 53/47

130 160 180

FRL

- / 60 / 60

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 1 x 13mm BGC Fireboard Side 2 1 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

35/29 37/31 37/32

45/37 46/38 46/40

45/37 46/39 47/40

116 146 166

TS006

TS010

TS011

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 1 x 10mm BGC SoundboardTM Side 2 1 x 10mm BGC SoundboardTM

Page 65: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

64

TIMBER FRAME INTERIOR WALL SYSTEMSTAGGERED STUD

FRL

- / 90 / 90

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 1 x 16mm BGC Fireboard Side 2 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

36/30 38/32 38/32

46/39 46/40 46/41

46/39 46/40 47/42

122 152 172

FRL

- / 120 / 120

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 2 x 13mm BGC Fireboard Side 2 2 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

42/36 43/37 44/37

52/46 53/48 53/48

53/47 53/48 53/49

142 172 192

FRL

- / 120 / 120

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 2 x 16mm BGC Fireboard Side 2 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

43/37 45/38 45/38

53/48 53/49 53/49

53/49 53/50 53/50

154 184 204

TS019

TS021

TS023

Page 66: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME INTERIOR WALL SYSTEMSTAGGERED STUD

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

65

FRL

- / - / -

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 1 x 6mm BGC DuralinerTM Side 2 1 x 10mm BGC Plasterboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

32/25 33/26 33/26

42/31 44/34 45/36

43/31 45/34 46/35

106 136 156

TS030

FRL

- / - / -

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 1 x 9mm BGC DuralinerTM Side 2 1 x 9mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

37/30 39/32 39/31

47/38 48/39 48/40

47/38 48/40 48/40

108 138 158

TS028

FRL

- / - / -

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 1 x 6mm BGC DuralinerTM Side 2 1 x 6mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

33/26 33/25 33/26

43/31 45/35 45/35

43/31 45/35 46/35

102 132 152

TS027

Page 67: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

66

TIMBER FRAME INTERIOR WALL SYSTEMSTAGGERED STUD

FRL

60 / 60 / 60

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 1 x 6mm BGC DuralinerTM (against studs) 1 x 13mm BGC Fireboard Side 2 1 x 6mm BGC DuralinerTM (against studs) 1 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

42/34 43/35 43/36

52/46 53/47 53/47

53/46 53/47 53/47

128 158 178

FRL

60 / 60 / 60

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 1 x 16mm BGC Fireboard (against studs) 1 x 6mm BGC DuralinerTM Side 2 1 x 16mm BGC Fireboard (against studs) 1 x 6mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

42/34 43/36 44/36

52/46 53/48 53/48

53/47 53/48 53/49

134 164 184

FRL

- / - / -

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 1 x 6mm BGC DuralinerTM Side 2 1 x 10mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

33/26 33/26 34/27

43/32 45/36 45/35

43/32 46/36 46/36

106 136 156

TS031

TS039

TS040

Page 68: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME INTERIOR WALL SYSTEMSTAGGERED STUD

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

67

FRL

90 / 90 / 90

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES MIN 20mm CLEARANCE BETWEEN STUD AND OPPOSING WALL LINING Side 1 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard Side 2 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

PLATE WIDTH mm 90 120 140

Rw/Rw+Ctr

42/34 43/36 44/36

52/46 53/48 53/48

53/47 53/48 53/49

134 164 184

PREVIOUSLY BGC DL004 TS042

Page 69: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

68

TIMBER FRAME INTERIOR WALL SYSTEMDOUBLE STUD

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Fireboard Side 2 1 x 13mm BGC Fireboard

FRL

- / 60 / 60

CAVITY WIDTH mmCAVITY INFILL

160 200 260 300Rw/Rw+Ctr

40/34 42/35 43/35 44/36 52/44 53/45 53/47 53/47 54/45 55/47 55/48 55/49 55/45 56/48 56/48 56/49 57/46 58/48 59/49 59/49 186 226 286 326

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 1 x 13mm BGC Plasterboard (against stud) 1 x 13mm BGC Fireboard Side 2 1 x 13mm BGC Plasterboard (against stud) 1 x 13mm BGC Fireboard

FRL

- / 60 / 60

CAVITY WIDTH mmCAVITY INFILL

160 200 260 300Rw/Rw+Ctr

46/37 47/38 48/38 49/39 57/48 57/49 58/49 58/51 60/50 61/52 61/53 61/53 61/50 61/52 62/54 62/55 63/52 64/54 65/55 65/55 212 252 312 352

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

TD011

TD013

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 1 x 10mm BGC Plasterboard (against studs) 1 x 16mm BGC Fireboard Side 2 1 x 10mm BGC Plasterboard (against studs) 1 x 16mm BGC Fireboard

FRL

- / 60 / 60

CAVITY WIDTH mm 160 200 260 300 Rw/Rw+Ctr 46/38 47/39 48/39 49/40 57/49 58/49 58/49 58/51 60/51 61/52 61/53 61/53 61/51 62/53 63/54 63/55 63/52 64/54 65/55 65/55 212 252 312 352

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

TD017

Page 70: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME INTERIOR WALL SYSTEMDOUBLE STUD

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

69

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm BGC Fireboard Side 2 2 x 16mm BGC Fireboard

FRL

- / 120 / 120

CAVITY WIDTH mmCAVITY INFILL

160 200 260 300 Rw/Rw+Ctr 48/39 49/41 51/42 52/43 60/52 61/54 61/55 61/56 62/54 63/55 64/57 64/57 63/54 64/56 65/57 65/58 65/54 66/57 67/58 67/59 224 264 324 364

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 2 x 13mm BGC Fireboard Side 2 2 x 13mm BGC Fireboard

FRL

- / 120 / 120

CAVITY WIDTH mmCAVITY INFILL

160 200 260 300 Rw/Rw+Ctr 48/40 50/41 51/43 52/43 60/51 60/53 61/55 61/55 62/53 63/55 63/56 63/57 63/53 64/55 64/56 64/57 65/54 65/55 66/57 66/58 212 252 312 352

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

TD021

TD023

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Fireboard Side 2 1 x 16mm BGC Fireboard

FRL

- / 60 / 60

60 / 60 / 60

CAVITY WIDTH mmCAVITY INFILL

160 200 260 300 Rw/Rw+Ctr 42/35 43/36 45/37 45/37 54/46 55/48 55/49 55/49 56/48 57/49 57/49 57/50 57/48 58/49 58/49 58/51 59/48 60/49 61/50 61/51 192 232 292 332

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

TD019

Page 71: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

70

TIMBER FRAME INTERIOR WALL SYSTEMDOUBLE STUD

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 3 x 16mm BGC Fireboard Side 2 3 x 16mm BGC Fireboard

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 1 x 9mm BGC DuralinerTM Side 2 1 x 9mm BGC DuralinerTM

FRL

- / 120 / 120

FRL

- / - / -

CAVITY WIDTH mm

CAVITY WIDTH mm

CAVITY INFILL

CAVITY INFILL

160 200 260 300 Rw/Rw+Ctr 54/45 56/46 58/48 59/49 67/59 68/61 69/62 69/63 69/61 70/62 71/64 71/65 70/61 71/63 72/64 72/65 72/61 73/63 73/65 73/65 256 296 356 396

160 200 260 300 Rw/Rw+Ctr 42/34 43/35 44/36 45/36 55/45 55/46 56/48 56/48 56/46 57/48 58/49 58/50 58/47 58/49 58/49 58/51 59/47 60/49 61/49 61/52 178 218 278 318

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 1 x 6mm BGC DuralinerTM Side 2 1 x 6mm BGC DuralinerTM

FRL

- / - / -

CAVITY WIDTH mmCAVITY INFILL

160 200 260 300 Rw/Rw+Ctr 38/30 38/31 39/32 40/32 51/41 51/43 52/44 52/45 52/42 53/45 54/46 54/46 53/42 54/45 55/47 55/47 55/43 56/46 57/48 57/49 172 212 272 312

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

TD026

TD027

TD028

Page 72: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME INTERIOR WALL SYSTEMDOUBLE STUD

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

71

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 1 x 6mm BGC DuralinerTM (against studs) 1 x 13mm BGC Fireboard Side 2 1 x 6mm BGC DuralinerTM (against studs) 1 x 13mm BGC Fireboard

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard Side 2 1 x 6mm BGC DuralinerTM (against studs) 1 x 16mm BGC Fireboard

FRL

60 / 60 / 60

FRL

90 / 90 / 90

CAVITY WIDTH mm

CAVITY WIDTH mm

CAVITY INFILL

CAVITY INFILL

160 200 260 300 Rw/Rw+Ctr 46/38 47/39 48/39 49/40 58/49 59/49 59/49 59/51 60/50 60/52 61/53 61/53 61/51 62/53 63/54 63/54 63/52 64/53 65/55 65/55 198 238 298 338

160 200 260 300 Rw/Rw+Ctr 48/39 49/40 51/41 52/42 60/51 61/53 61/54 61/55 62/53 63/54 63/56 63/57 63/53 64/54 64/56 64/57 65/53 65/55 66/57 66/58 204 244 304 344

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

MIN 20mm GAP BETWEEN STUD WALLS 2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Fireboard (against studs) 1 x 6mm BGC DuralinerTM Side 2 1 x 16mm BGC Fireboard (against studs) 1 x 6mm BGC DuralinerTM

FRL

60 / 60 / 60

CAVITY WIDTH mmCAVITY INFILL

160 200 260 300 Rw/Rw+Ctr 48/39 49/40 51/41 52/42 60/51 61/53 61/54 61/55 62/53 63/54 63/56 63/57 63/53 64/54 64/56 64/57 65/53 65/55 66/57 66/58 204 244 304 344

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

Nil9kg – 50mm Polyester – 1 side9kg – 50mm Polyester – 2 sides30kg – 75mm Polyester – 1 side30kg – 75mm Polyester – 2 sides

WALL THICKNESS mm

PREVIOUSLY BGC DL003

PREVIOUSLY BGC DL004

TD039

TD040

TD042

Page 73: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

72

INSTALLATION DETAILSTIMBER STUD

TIMBER FRAME WITH ONE LAYER BGC FIREBOARD - HORIZONTAL SHEETING

FASTENER SPACING2 Nails 50mm apart at 300mm max. centres

1 screw at 200mm max. centresAt Each Stud

Nails at 150mm max. centres Screws at

200mm max. centresNails at 150mm

max. centres Screws at 200mm max.

centres

LOCATION

Centre of the Board

Recessed Edges

Butt Joints

Corners & Openings

FIXING SPECIFICATIONS

TIMBER FRAME WITH ONE LAYER BGC FIREBOARD -VERTICAL SHEETING

FASTENER SPACING2 Nails 50mm apart at 300mm max. centres

1 screw at 200mm max. centresAt Each Stud

Nails at 150mm max. centres Screws at

200mm max. centresNails at 150mm

max. centres Screws at 200mm max.

centres

LOCATION

Centre of the Board

Recessed Edges

Butt Joints

Corners & Openings

FIXING SPECIFICATIONS

FRAMINGSoft Wood Timber

FIREBOARD THICKNESS13mm16mm

SCREW TYPENo 6 Type WNo 6 Type W

SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING SCREW LENGTH1ST LAYER

32mm45mm

Page 74: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

INSTALLATION DETAILSTIMBER STUD

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

73

TIMBER FRAME WITH TWO LAYERS BGC FIREBOARD - HORIZONTAL SHEETING

FASTENER SPACINGNails or Screws

600mm max. centresNails or Screws

600mm max. centresNails or Screws

600mm max. centres in stagered pattern

2 Nails 50mm apart at 300mm max. centres

1 screw at 200mm max. centres

Nails or screws at300mm max. centresNails at 150mm max.

centres Screws at 200mm max. centres

Nails at 150mm max. centres Screws

at 300mm max.centres

LOCATION

Centre of the Board

Recessed Edges

Butt Joints

Centre of the Board

Recessed Edges

Butt Jointson noggins

Corners & Openings

FIXING SPECIFICATIONSFIRST LAYER

SECOND LAYER

FRAMINGSoft Wood Timber

FIREBOARD THICKNESS13mm16mm

SCREW TYPENo 6 Type WNo 6 Type W

SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING SCREW LENGTH1ST LAYER

32mm45mm

2ND LAYER50mm65mm

Page 75: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

2 nails 50mm apart at300mm max. centre

1 scew at 200mm max. centres

Fasteners at each studNails 300mm max

Screws 150mm max centres

TIMBER FRAME WITH THREE LAYERS BGC FIREBOARD - VERTICAL SHEETING

2 nails 50mm apart at300mm max. centre

1 scew at 300mm max. centres

300mm max. centresLaminating Screws

200mm max. centresNail screws 150mm max

300mm max. centres

Centre of the Board

Recessed Edges

Butt Joints

Corners & Openings

Centre of the Board

Recessed Edges

Butt Joints on studs

FASTENER SPACING600mm max. centres600mm max. centres600mm max. centres

FASTENER SPACING600mm max. centres

Fasteners at each stud600mm max. centres

LOCATIONCentre of the Board

Recessed EdgesCorners & Openings

LOCATIONCentre of the Board

Recessed EdgesCorners & Openings

FIXING SPECIFICATIONS THREE LAYER VERTICAL-VERTICAL SHEETING (Shown)

FIRST LAYER

FIXING SPECIFICATIONS THREE LAYER HORIZONTAL

FIRST LAYER

SECOND LAYERSECOND LAYER

Laminating Screws at400mm max. grid

Laminating Screws200mm max. centres

Laminating Screws at400mm max. grid

Laminating Screws400mm max. centres

Centre of the BoardRecessed Edges

Corners & Openings

Butt Joints

Centre of the BoardRecessed Edges

Corners & Openings

Butt Joints

THIRD LAYERTHIRD LAYER

05 / TIMB

ER FR

AM

E INFO

RM

ATION

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

74

INSTALLATION DETAILSTIMBER STUD

FRAMINGSoft Wood Timber

FIREBOARD THICKNESS13mm16mm

SCREW TYPENo 6 Type WNo 6 Type W

SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING SCREW LENGTH1ST LAYER

32mm45mm

2ND LAYER50mm65mm

3RD LAYER50mm65mm

Page 76: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME EXTERIOR WALL SYSTEMSINGLE STUD

06 / EXTERIO

R W

ALL IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201375

FRL

60 / 60 / 60

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 7.5mm DuratexTM

Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE001

FRL

90 / 90 / 90

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 7.5mm DuratexTM Side 2 1 x 10mm BGC Plasterboard Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE002

FRL

60 / 60 / 60

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 9mm DuragridTM Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only Timber batten can be substituted for steel batten

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE003

90

41/35

45/38

45/38

123.5

90

45/39

48/42

48/42

123.5

90

38/27

45/34

45/34

125

120

Rw/Rw+Ctr

42/35

46/40

46/41

123.5

120

Rw/Rw+Ctr

45/39

48/44

48/45

123.5

120

Rw/Rw+Ctr

41/31

47/37

47/37

155

140

42/36

46/41

46/41

123.5

140

46/39

48/45

49/45

123.5

140

43/34

48/39

48/39

175

Page 77: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

06 / EXTERIO

R W

ALL IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201376

TIMBER FRAME EXTERIOR WALL SYSTEMSINGLE STUD

FRL

90 / 90 / 90

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 9mm DuragridTM Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only Timber batten can be substituted for stee

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE004

FRL

60 / 60 / 60

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 9mm DuracomTM Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE005

FRL

90 / 90 / 90

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 9mm DuracomTM Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE006

90

42/30

48/37

48/37

141

90

40/28

46/34

46/34

125

90

40/28

49/34

49/34

141

120

Rw/Rw+Ctr

45/35

50/40

50/40

171

120

Rw/Rw+Ctr

43/32

48/37

48/37

155

120

Rw/Rw+Ctr

44/32

50/37

50/37

171

140

47/37

51/41

51/41

191

140

44/34

48/38

48/38

175

140

45/34

51/39

51/39

191

Page 78: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

TIMBER FRAME EXTERIOR WALL SYSTEMSINGLE STUD

06 / EXTERIO

R W

ALL IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201377

FRL

60 / 60 / 60

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 14mm NulineTM Plus Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE007

FRL

90 / 90 / 90

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 14mm NulineTM Plus Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE008

FRL

60 / 60 / 60

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 9mm DurascapeTM Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE009

90

41/30

46/34

46/34

130

90

42/29

48/34

48/34

146

90

42/36

46/39

46/40

125

120

Rw/Rw+Ctr

41/31

47/37

47/37

160

120

Rw/Rw+Ctr

44/31

50/37

50/37

176

120

Rw/Rw+Ctr

43/36

46/41

46/41

155

140

44/33

48/38

48/38

180

140

46/33

50/38

50/38

196

140

43/37

46/41

46/42

175

Page 79: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

06 / EXTERIO

R W

ALL IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201378

TIMBER FRAME EXTERIOR WALL SYSTEMSINGLE STUD

FRL

90 / 90 / 90

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 9mm DurascapeTM Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE010

FRL

60 / 60 / 60

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 9mm DuragrooveTM Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE011

FRL

90 / 90 / 90

TIMBER STUDS AT 600mm MAX CENTRES WITH NOGGINS AT 1350mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 9mm DuragrooveTM Side 2 1 x 10mm BGC Plasterboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD WIDTH mm

TE012

90

45/39

48/43

48/43

141

90

42/36

46/39

46/39

128

90

45/39

48/43

48/43

141

120

Rw/Rw+Ctr

45/39

49/44

49/45

171

120

Rw/Rw+Ctr

43/36

46/41

46/41

155

120

Rw/Rw+Ctr

45/39

49/44

49/45

171

140

46/40

49/44

49/45

191

140

43/37

46/41

46/42

175

140

46/40

49/44

49/44

191

Page 80: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME EXTERIOR WALL SYSTEMSINGLE STUD

06 / EXTERIO

R W

ALL IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201379

FRL

60 / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 7.5mm DuratexTM Side 2 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE001

FRL

90 / 90 / 90

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 7.5mm DuratexTM Side 2 2 x 16mm BGC Fireboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE002

FRL

60 / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 9mm DuragridTM Side 2 1 x 16mm BGC Fireboard

Fire rated from outside only

Timber batten can be substituted for steel

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE003

64

42/36

49/41

50/41

103.5

64

48/41

56/50

57/50

135.5

64

42/30

49/37

49/37

105

76

42/35

50/43

51/43

115.5

76

48/41

57/51

57/51

147.5

76

44/33

51/40

51/40

117

92

43/36

51/44

51/44

131.5

92

49/42

57/51

57/51

163.5

92

46/36

52/42

52/42

133

150

45/37

52/47

52/47

189.5

150

52/44

57/52

57/52

221.5

150

50/42

55/46

55/46

191

Rw/Rw+Ctr

Rw/Rw+Ctr

Rw/Rw+Ctr

Page 81: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

06 / EXTERIO

R W

ALL IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201380

STEEL FRAME EXTERIOR WALL SYSTEMSINGLE STUD

FRL

90 / 90 / 90

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 9mm DuragridTM Side 2 2 x 16mm BGC Fireboard

Fire rated from outside only

Timber batten can be substituted for steel

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE004

FRL

60 / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 9mm DuracomTM Side 2 1 x 16mm BGC Fireboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE005

FRL

90 / 90 / 90

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 9mm DuracomTM Side 2 2 x 16mm BGC Fireboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE006

64

50/40

57/46

57/46

137

64

44/33

49/37

50/38

105

64

51/41

57/45

57/45

137

76

51/42

58/48

58/48

149

76

45/35

52/40

52/40

117

76

53/42

58/46

58/46

149

92

52/43

59/49

59/49

165

92

47/37

53/42

53/42

133

92

54/44

59/48

59/48

165

150

54/46

60/53

60/53

223

150

52/42

56/46

56/46

191

150

56/46

59/51

59/51

223

Rw/Rw+Ctr

Rw/Rw+Ctr

Rw/Rw+Ctr

Page 82: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

STEEL FRAME EXTERIOR WALL SYSTEMSINGLE STUD

06 / EXTERIO

R W

ALL IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201381

FRL

60 / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 14mm NulineTM Plus Side 2 1 x 16mm BGC Fireboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE007

FRL

90 / 90 / 90

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 14mm NulineTM Plus Side 2 2 x 16mm BGC Fireboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE008

FRL

60 / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 9mm DurascapeTM Side 2 1 x 16mm BGC Fireboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE009

64

45/35

50/38

50/38

110

64

52/40

57/44

57/44

142

64

42/36

50/42

50/42

105

76

47/36

51/40

51/40

122

76

51/39

58/45

58/44

154

76

42/36

51/44

51/44

117

92

46/36

52/41

52/41

138

92

53/41

58/46

58/46

170

92

43/36

52/44

52/45

133

150

50/40

54/45

54/45

196

150

56/45

59/50

59/50

228

150

45/38

53/47

53/48

191

Rw/Rw+Ctr

Rw/Rw+Ctr

Rw/Rw+Ctr

Page 83: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

06 / EXTERIO

R W

ALL IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201382

STEEL FRAME EXTERIOR WALL SYSTEMSINGLE STUD

FRL

90 / 90 / 90

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 9mm DurascapeTM Side 2 2 x 16mm BGC Fireboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE010

FRL

60 / 60 / 60

STEEL STUDS AT 600mm MAX CENTRES Side 1 1 x 16mm BGC Wet Area Fireboard 1 x 9mm DuragrooveTM Side 2 1 x 16mm BGC Fireboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE011

FRL

90 / 90 / 90

STEEL STUDS AT 600mm MAX CENTRES Side 1 2 x 16mm BGC Wet Area Fireboard 1 x 9mm DuragrooveTM Side 2 2 x 16mm BGC Fireboard

Fire rated from outside only

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

WALL THICKNESS mm

STUD DEPTH mm

SE012

64

48/41

57/50

57/51

137

64

42/36

50/42

50/42

105

64

48/41

57/50

57/51

137

76

49/42

57/51

57/51

149

76

42/36

51/44

51/44

117

76

49/42

57/51

57/51

149

92

50/43

57/51

58/52

165

92

43/36

52/44

52/45

133

92

50/43

57/51

58/52

165

150

52/44

58/53

58/53

223

150

45/38

53/47

53/48

191

150

52/44

58/53

58/53

223

Rw/Rw+Ctr

Rw/Rw+Ctr

Rw/Rw+Ctr

Page 84: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

06 / EXTERIO

R W

ALL IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201383

INSTALLATION DETAILSEXTERIOR WALLS

TIMBER FRAME WITH ONE LAYER BGC WET AREA FIREBOARD60/60/60 BOUNDARY WALL

TIMBER FRAME WITH TWO LAYERS BGC WET AREA FIREBOARD90/90/90 BOUNDARY WALL

FASTENER SPACINGNails or Screws

600mm max. centresNails or Screws

600mm max. centresNails or Screws

600mm max. centres in stagered pattern

2 Nails 50mm apart at 300mm max. centres

1 screw at 200mm max. centresAt Each Stud

Nails at 150mm max. centres Screws at

200mm max. centresNails at 150mm

max. centres Screws at 300mm max.

centres

LOCATION

Centre of the Board

Recessed Edges

Butt Joints

Centre of the Board

Recessed Edges

Butt Joints

Corners & Openings

FIXING SPECIFICATIONSFIRST LAYER

SECOND LAYER

FASTENER SPACING2 Nails at 300mm max

centres 1 screw at 200mm max centres

At each studNails at 150mm max

centres screws at 200mm max centres

Nails at 150mm max centres screws at

200mm max centres

LOCATION

Centre of the Board

Recessed Edges

Butt Joints

Corners & Openings

FIXING SPECIFICATIONS

FRAMINGSoft Wood Timber

FIREBOARD THICKNESS16mm

SCREW TYPENo 6 Type W

SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING SCREW LENGTH1ST LAYER

45mm

FRAMINGSoft Wood Timber

FIREBOARD THICKNESS16mm

SCREW TYPENo 6 Type W

SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING SCREW LENGTH1ST LAYER

45mm

Page 85: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

INSTALLATION DETAILSEXTERIOR WALLS

06 / EXTERIO

R W

ALL IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201384

STEEL FRAME WITH ONE LAYER BGC WET AREA FIREBOARD60/60/60 BOUNDARY WALL

FASTENER SPACING

300mm max. centres

At Each Stud

100mm max. centres

300mm max.centres

LOCATION

Centre of the Board

Recessed Edges

Butt Joints

Corners & Openings

FIXING SPECIFICATIONS

STEEL FRAME WITH TWO LAYERS BGC WET AREA FIREBOARD 90/90/90 BOUNDARY WALL

FASTENER SPACING

600mm max. centres

600mm max. centres

600mm max. centres

300mm max. centres

At Each Stud

200mm max. centres

300mm max.centres

LOCATION

Centre of the Board

Recessed Edges

Butt Joints

Centre of the Board

Recessed Edges

Butt Joints

Corners & Openings

FIXING SPECIFICATIONSFIRST LAYER

SECOND LAYER

FRAMINGLightweight Steel up to

0.8mmLightweight Steel 0.8mm

to 1.6mm

FIREBOARD THICKNESS

16mm

16mm

SCREW TYPE

No 6 Type S Needle Point

No 6 Type D Drill Point

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING SCREW LENGTH1ST LAYER

30mm

32mm

FRAMINGLightweight Steel up to

0.8mmLightweight Steel 0.8mm

to 1.6mm

FIREBOARD THICKNESS

16mm

16mm

SCREW TYPE

No 6 Type S Needle Point

No 6 Type D Drill Point

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING SCREW LENGTH1ST LAYER

30mm

32mm

2ND LAYER

45mm

45mm

Page 86: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

FLOOR / CEILINGTIMBER OR STEEL JOISTS

FRL

- / - / -

FRL

- / - / -

FRL

- / - / -

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGMIN CAVITY DEPTH OF 190mm Ceiling Lining 1 x 13mm BGC Plasterboard

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGMIN CAVITY DEPTH OF 190mmCeiling Lining 2 x 13mm BGC Plasterboard

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGMIN CAVITY DEPTH OF 190mmCeiling Lining 1 x 10mm BGC Ceilingboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

39/33

40/36

40/36

Rw/Rw+Ctr

41/35

42/39

42/39

Rw/Rw+Ctr

37/31

39/35

39/35

C001

C002

C003

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201385

Page 87: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201386

FLOOR / CEILINGTIMBER OR STEEL JOISTS

FRL

- / - / -

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGMIN CAVITY DEPTH OF 190mmCeiling Lining 2 x 10mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

41/36

42/39

42/39

FRL

90 / 90 / 90

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGMIN CAVITY DEPTH OF 190mmCeiling Lining 1 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

43/38

44/41

44/41

C004

C005

FRL

30 / 30 / 30

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGMIN CAVITY DEPTH OF 190mmCeiling Lining 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

40/35

40/38

40/38

C018

Page 88: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201387

FLOOR / CEILINGTIMBER OR STEEL JOISTS

FRL

90 / 90 / 90

FRL

120 / 120 / 120

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGMIN CAVITY DEPTH OF 190mmCeiling Lining 2 x 16mm BGC Fireboard

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGMIN CAVITY DEPTH OF 190mmCeiling Lining 3 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

43/38

44/41

44/41

Rw/Rw+Ctr

45/40

46/44

46/44

C006

C007

Page 89: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201388

FLOOR / CEILINGTIMBER OR STEEL JOISTS WITH FURRING CHANNELS TIMBER OR STEEL JOISTS WITH FURRING CHANNELS

Rw/Rw+Ctr

40/33

43/39

43/39

Rw/Rw+Ctr

40/34

43/39

43/39

Rw/Rw+Ctr

39/33

42/38

42/38

FRL

- / - / -

FRL

- / - / -

FRL

- / - / -

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm Ceiling Lining 1 x 10mm BGC Ceilingboard

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm Ceiling Lining 1 x 13mm BGC Plasterboard

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm Ceiling Lining 1 x 6mm BGC DuralinerTM

(furring channel at 450mm max centres)

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

C010

C011

C012

Page 90: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201389

FLOOR / CEILINGTIMBER OR STEEL JOISTS WITH FURRING CHANNELS

FRL

90 / 90 / 90

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm Ceiling Lining 1 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

44/39

47/44

47/44

FRL

- / - / -

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm Ceiling Lining 1 x 9mm BGC DuralinerTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

43/37

45/41

45/41

FRL

60 / 60 / 60

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm Ceiling Lining 2 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

43/38

46/43

46/43

C013

C014

C015

Page 91: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201390

FLOOR / CEILINGTIMBER OR STEEL JOISTS WITH FURRING CHANNELS

Rw/Rw+Ctr

46/41

49/47

49/47

Rw/Rw+Ctr

44/39

47/44

47/44

FRL

90 / 90 / 90

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm Ceiling Lining 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

FRL

120 / 120 / 120

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm Ceiling Lining 3 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

C016

C017

Page 92: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201391

FLOOR / CEILINGTIMBER OR STEEL JOISTS WITH FURRING CHANNELS

AND ACOUSTIC RESILIENT MOUNTS

FRL

- / - / -

FRL

- / - / -

FRL

- / - / -

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS MIN CAVITY DEPTH OF 232mm Ceiling Lining 1 x 13mm BGC Plasterboard

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS MIN CAVITY DEPTH OF 232mm Ceiling Lining 1 x 10mm BGC SoundboardTM

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS MIN CAVITY DEPTH OF 232mm Ceiling Lining 2 x 10mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

42/34

49/42

50/43

Rw/Rw+Ctr

42/34

49/42

50/43

Rw/Rw+Ctr

47/38

54/48

55/49

C020

C021

C022

Page 93: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201392

FLOOR / CEILINGTIMBER OR STEEL JOISTS WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS

FRL

60 / 60 / 60

FRL

90 / 90 / 90

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS MIN CAVITY DEPTH OF 232mm Ceiling Lining 2 x 13mm BGC Fireboard

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS MIN CAVITY DEPTH OF 232mm Ceiling Lining 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

FRL

90 / 90 / 90

19mm TONGUE & GROOVE PARTICLEBOARD FLOORINGWITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS MIN CAVITY DEPTH OF 232mm Ceiling Lining 1 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

48/39

55/49

56/50

Rw/Rw+Ctr

48/39

55/49

56/50

Rw/Rw+Ctr

49/41

56/49

56/50

C023

C024

C025

Page 94: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201393

ROOF / CEILINGTIMBER TRUSSES

FRL

- / - / -

FRL

- / - / -

FRL

- / - / -

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS MAX JOIST OR TRUSS SPACING AT 600mm Ceiling Lining 1 x 10mm BGC SoundboardTM

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS MAX JOIST OR TRUSS SPACING AT 600mm Ceiling Lining 2 x 10mm BGC SoundboardTM

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS MAX JOIST OR TRUSS SPACING AT 600mm Ceiling Lining 1 x 13mm BGC Plasterboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

41/32

42/32

Rw/Rw+Ctr

-

45/36

45/37

Rw/Rw+Ctr

-

41/32

42/32

C030

C031

C032

Page 95: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201394

ROOF / CEILINGTIMBER TRUSSES

FRL

- / - / -

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS MAX JOIST OR TRUSS SPACING AT 600mm Ceiling Lining 1 x 13mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

42/34

43/34

C033

FRL

60 / 60 / 60

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS MAX JOIST OR TRUSS SPACING AT 600mm Ceiling Lining 2 x 13mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

45/37

46/38

C037

FRL

90 / 90 / 90

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS MAX JOIST OR TRUSS SPACING AT 600mm Ceiling Lining 1 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

46/38

47/39

C034

Page 96: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201395

ROOF / CEILINGTIMBER TRUSSES

FRL

90 / 90 / 90

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS MAX JOIST OR TRUSS SPACING AT 600mm Ceiling Lining 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

46/38

46/38

C035

FRL

120 / 120 / 120

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS MAX JOIST OR TRUSS SPACING AT 600mm Ceiling Lining 3 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

48/41

48/40

C036

Page 97: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201396

ROOF / CEILINGFURRING CHANNELS

FRL

- / - / -

FRL

- / - / -

FRL

- / - / -

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS Ceiling Lining 1 x 10mm BGC Plasterboard

PITCHED TILED ROOF WITH OR WITHOUT350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS Ceiling Lining 1 x 10mm BGC SoundboardTM

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS Ceiling Lining 1 x 13mm BGC SoundboardTM

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

40/31

40/31

Rw/Rw+Ctr

-

43/34

43/34

Rw/Rw+Ctr

-

44/37

44/36

C040

C041

C042

Page 98: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201397

ROOF / CEILINGFURRING CHANNELS

FRL

- / - / -

FRL

90 / 90 / 90

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS Ceiling Lining 1 x 6mm BGC DuralinerTM (Furring channels at 450 max centres)

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS Ceiling Lining 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

FRL

90 / 90 / 90

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS Ceiling Lining 1 x 13mm BGC Fireboard 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

41/32

41/32

Rw/Rw+Ctr

-

48/41

48/41

Rw/Rw+Ctr

-

48/41

48/41

C043

C044

C045

Page 99: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201398

ROOF / CEILINGFURRING CHANNELS

FRL

120 / 120 / 120

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS Ceiling Lining 3 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

50/42

51/43

C046

Page 100: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

201399

ROOF / CEILINGFURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS

FRL

- / - / -

FRL

- / - / -

FRL

90 / 90 / 90

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS Ceiling Lining 1 x 10mm BGC SoundboardTM

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS Ceiling Lining 2 x 10mm BGC SoundboardTM

PITCHED TILED ROOF WITH OR WITHOUT 350g/m2 SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS Ceiling Lining 1 x 13mm BGC Fireboard (against frame) 1 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

44/35

45/35

Rw/Rw+Ctr

-

49/38

50/39

Rw/Rw+Ctr

-

50/40

51/40

C050

C051

C052

Page 101: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

2013100

ROOF / CEILINGFURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS

FRL

90 / 90 / 90

PITCHED TILED ROOF WITH OR WITHOUT 350g/m SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS Ceiling Lining 2 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

FRL

120 / 120 / 120

PITCHED TILED ROOF WITH OR WITHOUT 350g/m SARKING OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS Ceiling Lining 3 x 16mm BGC Fireboard

CAVITY INFILL

Nil

9kg - 50mm Polyester

30kg - 75mm Polyester

Rw/Rw+Ctr

-

50/40

52/41

Rw/Rw+Ctr

-

53/43

54/44

C053

C054

Page 102: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

2013101

INSTALLATION DETAILSCEILING

STEEL OR TIMBER WITH ONE OR TWO LAYERS OF BGC FIREBOARD – NAIL OR SCREW FIXING

FASTENER SPACINGEach framing member at 10 to 16mm from sheet edges and at 200mm

max centres150mm max centres150mm max centres

Cornice finish - 200mm max centres. Set finish -

150mm max centres

Framing at 450mm - 150mm max centres Framing at 600mm -

within 50mm of centre line between framing & fix to ist layer with laminating screws at 200mm max centres150mm max centres

Cornice finish - 200mm max centres. Set finish -

150mm max centres

NOTE: One layer systems to be fixed as per

2nd layer. Butt joints between framing are to be fully back blocked

and fixed with laminating screws.

LOCATION

Centre of the Board

Butt JointsOpenings

Sheet ends

Butt Joints

Openings

Sheet ends

FIXING SPECIFICATIONS ONE OR TWO LAYERS OF BGC FIREBOARD-

NAIL OR SCREW FIXINGFIRST LAYER

SECOND LAYER

Note: Refer to page 10 for screw lengths.

Page 103: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

07 / CEILIN

G IN

FOR

MATIO

NB

GC

FIRE & A

CO

US

TIC / M

AR

CH

2013102

INSTALLATION DETAILSCEILING

STEEL OR TIMBER WITH THREE LAYERS OF BGC FIREBOARD – NAIL OR SCREW FIXING

Each framing member at 10 to 16mm from sheet

edges and at 200mm max centres

150mm max centres150mm max centres

Cornice finish - 200mm max centres Set finish - 150mm

max centres

Each framing member at 10 to 16mm from sheet edges and at 200mm

max centresWithin 50mm of centre line between framing &

fix to previous layer with laminating screws at 200mm max centres150mm max centres

Cornice finish - 200mm max centres. Set finish -

150mm max centres

Centre of the Board

Butt JointsOpenings

Sheet ends

Centre of the Board

Butt Joints

Openings

Sheet ends

FASTENER SPACING

150mm max centres150mm max centres

Cornice finish - 200mm max centres Set finish - 150mm

max centres

LOCATIONCentre of the Board

Butt JointsOpenings

Sheet ends

FIXING SPECIFICATIONS THREE OF BGC FIREBOARD - NAIL OR SCREW FIXING

FIRST LAYER

SECOND LAYER

THIRD LAYER

Note: Refer to page 10 for screw lengths.

Page 104: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

08 / CO

LUM

NS

/ BEA

MS

/ PEN

ETRATIO

NS

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

103

COLUMN OR BEAM

STEEL OR TIMBER WITH ONE OR TWO LAYERS OF BGC FIREBOARD – NAIL OR SCREW FIXING

• Steel angle fixed to the soffit or wall junction. • Universal Encasement Clips friction fitted to the remaining column/beam flanges. • Wall Furring Track is held in the back tongue of the clip. • Noggings at each end of the column/beam and behind plasterboard butt joins in single layer systems.

30/-/-60/-/-90/-/-90/-/-

120/-/-180/-/-

CB01CB02CB03CB04CB05CB06

1 x 13mm BGC Fireboard2 x 13mm BGC Fireboard2 x 16mm BGC Fireboard3 x 13mm BGC Fireboard3 x 16mm BGC Fireboard4 x 16mm BGC Fireboard

FRL SYSTEM NO. LININGS

Page 105: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

08 / CO

LUM

NS

/ BEA

MS

/ PEN

ETRATIO

NS

104

COLUMN OR BEAM

30/-/-60/-/-90/-/-

120/-/-180/-/-

CB07CB08CB09CB10CB11

1 x 13mm BGC Fireboard2 x 13mm BGC Fireboard2 x 16mm BGC Fireboard3 x 16mm BGC Fireboard4 x 16mm BGC Fireboard

FRL SYSTEM NO. LININGS

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

STEEL OR TIMBER WITH ONE OR TWO LAYERS OF BGC FIREBOARD – NAIL OR SCREW FIXING

Page 106: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

08 / CO

LUM

NS

/ BEA

MS

/ PEN

ETRATIO

NS

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

105PENETRATIONS

TYPICAL

Special design considerations apply to Fire Rated walls in order to maintain the Fire Rating (FRL) of a system.

• Electrical penetrations must not be placed back to back or more than one penetration per stud spacing.• Proprietary Fire Rated switch boxes are to be used.• BGC Plasterboard recommends the use of min R1.5 insulation batt be included in the wall cavity to assist in maintaining acoustic integrity.• All penetrations shall be sealed with an approved AS/NZS 1530.4 Fire Rated mastic filler. See Figure 1.• Where plumbing penetrations are required - all pipework must be self supporting.

FIGURE 1Pipe Penetration Through Wall (copper)

FIGURE 2 Pipe Penetration Through Ceiling

FIGURE 3 Control Joint - Wall Frame Double Layer

FIGURE 4 Control Joint - Wall Frame Single Layer

FIGURE 5 Control Joint - Wall Frame

FIGURE 6 Electrical Penetration Through Wall (Typical)Note: Do not place switch boxes back to back.

Wire meshflame guard

Fire rated mastic filler

15mm Min

100mm Max(copper) pipe

6mm

I.B.S. Fyreguardfoam 50 x 20

Proprietery firerated switch box

installed tomanufacturers

recommendations

Fire rated masticFire rated mastic

Backing rod

Additional studrequired at control joint

Rondo P53control joint

typical

20 mm min

15 mmFire rated masticMin depth 15mm

Top andbottom track isdiscontinuous

20mm

Fire ratedmastic fillerBacking rod

(not fire rated)Pipewor

k

(152mmmax diam

)

BGC Fibre Cement sheeting

Backing rod

Additional studrequired at control joint

10 mmFire rated masticMin depth 15mm

Top andbottom track isdiscontinuous

Backing rod

15 mm min

Additional studrequired at control joint

Rondo P53control joint

typical

15 mmFire rated masticMin depth 15mm

Top andbottom track isdiscontinuous

BGCFireboard

BGC Fireboard

BGC Fireboard

BGC Fireboard

BGC Fireboard

BGC Fireboard

Page 107: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

08 / CO

LUM

NS

/ BEA

MS

/ PEN

ETRATIO

NS

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

106

PENETRATIONSTYPICAL

FIRE PENETRATIONS FOR SINGLE, DOUBLE & STAGGERED STUD WALLS - ELEVATION

Page 108: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

BG

C FIR

E & AC

OU

STIC

/ MA

RC

H 2013

107WARRANTY

We warrant that our products are free from defects caused by faulty manufacture or materials for a period of 15 years from the date of purchase. If you acquire any defective products, we will repair or

replace them, supply equivalent replacement products or refund the purchase price within 30 days of receiving a valid claim subject to

product inspection and confirmation of the existence of a defect by BGC. We will bear the cost of any such repair, replacement or refund.

This warranty is given by:BGC Plasterboard Pty Ltd

Ground Floor, 290 Bushmead Rd, Hazelmere, WA 6055Phone: (08) 9374 2900 Fax: (08) 9374 2901

To claim under this warranty, you must provide proof of purchase as a consumer and make a written claim (including any costs of claiming)

to us at the address specified above within 30 days after the defect was reasonably apparent, or if the defect was reasonably apparent prior to installation, the claim must be made prior to installation. You may not

claim under this warranty for loss or damage caused by:• faulty or incorrect installation by non-BGC installers (BGC’s installation

procedures are at www.bgc.com.au/plasterboard); • failure to comply with the Building Code of Australia or any applicable legislation, regulations approvals and standards; • products not made or supplied by BGC; • abnormal use of the product; or • normal wear and tear.

The benefits available under this warranty are in addition to other rights and remedies of the consumer under the law. Our goods come with guarantees that cannot be excluded under the Australian Consumer

Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.

You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a

major failure.

Page 109: BGC PLASTERBOARD FIRE & ACOUSTIC - SHG Trade Solutions Brochure... · 2014. 10. 13. · The BGC Plasterboard Fire and Acoustic Guide has been designed to assist architects, specifiers,

Australian Owned & Manufactured www.bgc.com.au/plasterboard www.bgcinnovadesign.com.au

CO

NTAC

T

ADELAIDETELEPHONE 08 8250 4962BRISBANETELEPHONE 07 2371 1711MELBOURNETELEPHONE 03 9392 9444

PERTHTELEPHONE 08 9334 4900SYDNEYTELEPHONE02 9771 9660NEW ZEALANDTELEPHONE0011 64 9264 1457