bid document and special terms & conditions for · bid document and special terms &...

124
AUCTION CATALOGUE BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF 840 MW CAPACITY (4 X 50 MW + 2 X100 MW + 4X110 MW) Auction No. MSTC/RNC/PATRATU VIDYUT UTPADAN NIGAM LIMITED/6/RAMGARH/19-20/17378 Auction Opening Date & Time 15-10-2019::11:00:00 Auction Closing Date & Time 15-10-2019::15:00:00 Inspection Starting Date & Time 02-09-2019::10:00:00 Inspection Closing Date & Time 14-10-2019::17:00:00 Pre-Bid EMD Rs.8,00,00,000/- (INDIAN RUPEES EIGHT CRORES) Starting Price Rs 100,00,00,000/- (INDIAN RUPEES HUNDRED CRORES) Minimum Bid Increment Rs.5,00,000/- (INDIAN RUPEES FIVE LAKHS) Bid Validity period 120 calendar days Seller Details Seller /Company Name Patratu Vidyut Utpadan Nigam limited (PVUNL) Location P.O.-Patratu,Dist-Ramgarh,Jharkhand-829119 Area PTPS, Patratu Approach from Nearby Cities Ranchi (40 Km), Ramgarh (30 Km), Hazaribagh (50 Km) Country India Contact Person at PVUNL 1. Mr. Faiz Taiyab, AGM (De-Commissioning), Cell No 7759903977, email id : [email protected] 2. Mr. S K D Kayasth, AGM (C&M), Cell No 9650992870, email: [email protected] 3. P K Bhoi, DGM (C&M), Cell No 7667509268, email: [email protected] 4. Kumar Niket, Sr Manager (Decommissioning), Cell No 7070096724 , email id : [email protected] Contact Person at MSTC Mr. P Biswas, AM Cell No: 9903248755, email ID: [email protected] Mr. R. K. Singh, Branch Manager, Cell No: 8336928548, email ID: [email protected] PATRATU

Upload: others

Post on 25-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

AUCTION CATALOGUE

BID DOCUMENT AND SPECIAL TERMS & CONDITIONS

FOR

SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF

840 MW CAPACITY (4 X 50 MW + 2 X100 MW + 4X110 MW)

Auction No. MSTC/RNC/PATRATU VIDYUT UTPADAN NIGAM

LIMITED/6/RAMGARH/19-20/17378

Auction Opening Date & Time 15-10-2019::11:00:00

Auction Closing Date & Time 15-10-2019::15:00:00

Inspection Starting Date & Time 02-09-2019::10:00:00

Inspection Closing Date & Time 14-10-2019::17:00:00

Pre-Bid EMD Rs.8,00,00,000/- (INDIAN RUPEES EIGHT CRORES)

Starting Price Rs 100,00,00,000/- (INDIAN RUPEES HUNDRED CRORES)

Minimum Bid Increment Rs.5,00,000/- (INDIAN RUPEES FIVE LAKHS)

Bid Validity period 120 calendar days

Seller Details

Seller /Company Name Patratu Vidyut Utpadan Nigam limited (PVUNL)

Location P.O.-Patratu,Dist-Ramgarh,Jharkhand-829119

Area PTPS, Patratu

Approach from Nearby Cities Ranchi (40 Km), Ramgarh (30 Km), Hazaribagh (50

Km)

Country India

Contact Person at PVUNL

1. Mr. Faiz Taiyab, AGM (De-Commissioning),

Cell No 7759903977, email id : [email protected]

2. Mr. S K D Kayasth, AGM (C&M),

Cell No 9650992870, email: [email protected]

3. P K Bhoi, DGM (C&M),

Cell No 7667509268, email: [email protected]

4. Kumar Niket, Sr Manager (Decommissioning),

Cell No 7070096724 , email id : [email protected]

Contact Person at MSTC

Mr. P Biswas, AM

Cell No: 9903248755, email ID: [email protected]

Mr. R. K. Singh, Branch Manager,

Cell No: 8336928548, email ID: [email protected]

PATRATU

Page 2: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

2

I n d e x

Description Page Nos.

1. Auction Details 3

2. Material Details (Broad Description) 4

3. List of Exclusions 4

3.1 Switchyard Details (falling under “Not for Sale with Plant Auction”) 5

4. List of Temporary Exclusions 5

5. Onsite Inspection 5

6. Brief History of Plant 8

7. Sequence of Disposal 9

8. Detail of List of Items under Disposal 11

9. Special Terms and Conditions of Sale of De-Commissioned Plant 101

10. Terms and Conditions of De-Commissioned Plant 105

11. Annexures 127

List of Tables:

Table – 1: List of Exclusions (Indicative List)

Table – 2: List of Temporary Exclusions (to be disposed off after disposal of sixth segment)

Table – 3: Status of Generating Units

Table – 4: Segment wise sequence of disposal

Table – 5: Summary of weights

Page 3: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

3

1. Auction Details

ONLINE AUCTION OF 840 MW DE-CMMISSIONED THERMAL POWER PLANT OF PTPS,

PATRATU Being sold on “AS IS WHERE IS AND NO COMPLAINT BASIS”

Seller Details

Seller /Company Name Patratu Vidyut Utpadan Nigam Limited , Patratu- 829119

Location P.O.-Patratu, Distt- Ramgarh, Jharkhand

Area Patrratu Thermal Power Station

Nearest City Ranchi (40Km), Ramgarh (30Km), Hazaribagh (50 Km)

Country INDIA

Contact Person at PVUNL, Patratu

1. Faiz Taiyab, AGM (De-Commissioning), Cell No

7759903977, email: [email protected]

2. S K D Kayasth, AGM(C&M), Cell No 9650992870,

email: [email protected]

3. P K Bhoi, DGM (C&M), Cell No 7667509268, email:

[email protected]

4. Kumar Niket, Sr Manager (Decommissioning), Cell No

7070096724 , email id : [email protected]

Contact Person at MSTC, Ranchi

Mr. P Biswas, AM

Cell No: 9903248755, email ID: [email protected]

Mr. R. K. Singh, Branch Manager,

Cell No: 8336928548, email ID: [email protected]

Page 4: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

4

2. Material Details

LOT

NO MATERIA

L

QTY UOM GST TCS

PTPS

(Unit 1

to 10)

DISMANTLING AND DISPOSAL OF

DECOMMISSIONED THERMAL POWER PLANT

OF 840 MW CAPACITY COMPRISING OF 400MW

RUSSIAN UNITS (4X50MW + 2X100MW) AND 440

MW INDIAN UNITS(4X110MW) OF

ERSTWHILE PTPS, PATRATU INCLUDING ALL

THE PLANT & MACHINERY, CIVIL STRUCTURE,

PIPE LINES, CABLES, ETC. EXCLUIDING

SWITCHYARD AND OTHER LISTED EXCLUSION

MARKED “NOT FOR SALE WITH PLANT

AUCTION”.

1

Lot

As applicable on the date of

payment

As applicable

on the

date of

payment

NOTE: -

1. Taxes and duties will be charged at the rates prevailing at the time of invoicing.

2. GST is applicable on the entire lot.

3. The following items, which are falling within the area of disposal, are not part of the sale.

The successful bidder will not be allowed to dismantle / lift these items:

3. Exclusion Details

Table – 1: List of Exclusions (Indicative List)

Sl. No. Item description

1. All land belonging to PVUNL /taken on lease by it inside and outside the premises of

PVUNL, Patratu.

2. All trees

3. All Watchtowers and poles being used for lighting purposes.

4. Boundary wall with all gates and associated fencing

5. Switchyard, associated cables & control systems and its compressed air system

6. Coal in the bunkers of Unit # 4, 6 and 10 (Bidder has to evacuate the coal from Bunker and

store at identified place inside plant premises as per instruction of EIC).

7. Administrative building including civil structure with all furniture, fans, coolers, ACs,

files, record and computers etc.

8. Plant Canteen and FQA Building including laboratory, civil structure with all furniture,

fans, coolers, ACs, files, record, computers etc.

9 All furniture, Fans, Coolers, ACs‟, Files, Records and Computers of Utility Building

10. Items stored in some of the rooms in the Utility Building being used as stores

11. Items marked “Not for Sale with Plant Auction” in Plant area

12. HFO (including sludge settled at bottom of tanks and associated pipe lines), LDO (including

sludge settled at bottom of tanks associated pipe lines), sulphuric acid, etc.

13 High Mast Lights erected for area lighting

Page 5: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

5

3.1 Switchyard (Exclusion)

All Switchyard equipment and accessories inside Switchyard boundary and related relay panels

in Unit#10 relay room and MCB, associated power and control cables and systems are excluded

from Sale. Any equipment related to the operation and maintenance of the Switchyard are part

of the exclusion.

4. Temporary Exclusions

The items shown under Table - 2 form the part of initial exclusion. However, these items are part of sale and will be

disposed as per instruction of PVUNL as last segment after disposal of 06 (six) segments linked to the Payment

Term within the overall disposal period of 30 months from the date of issue of Sale Release Order . The price

offered in e-Auction by the bidder will be inclusive of items mentioned in Table-2.

Table – 2: List of Temporary Exclusions (to be disposed off after disposal of sixth segment)

Sl. No. Item description

1 Workshop

2 Indian Side DM Plant

3 Utility Building

4 HT & LT Switch Gear of Main Power House

5 All cables dismantled from MPH.

6 Fire Fighting System (Old Fire Tenders, Fire Pumps and Fire Station in Unit 7).

5. Onsite Inspection

i. Plant Location and Address:

PATRATU VIDYUT UTPADAN NIGAM

LIMITED UTILITY BUILDING, PO – PTPS,

PATRATU

DT – RAMGARH, JHARKHAND – 829119

ii. Inspection of Plant shall be allowed on all working days with at least one-day notice in advance to

AGM (De-Commissioning) or AGM(C&M), PVUN, Patratu. Refer to the format for inspection

(Annexure-I) appended in this catalogue at page 6.

iii. Buyers are required to submit the duly filled in prescribed format

iv. Customers visiting the site are required to carry the following 3 items with them.

1. Photo identity proof of each visitor.

2. Plant visit request (in given format) on Company letterhead.

3. Registered Bidder’s photo Identity Card issued by MSTC Limited.

v. Inspection Period (from 02.09.2019, 10:00 A.M. to 14.10.2019, 5:00 P.M. during working days of PVUNL).

Page 6: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

6

Annexure - I

FORMAT FOR INSPECTION

(To be printed on company letter head)

To

The AGM (Decommissioning)

PVUNL, Patratu.

Subject: - Request for permission to visit PVUNL premises regarding sale of 840 MW

(4x50MW+2X100MW +4X110MW) decommissioned power plant of PTPS, Patratu

Dear Sir,

As we are interested to participate in the upcoming online auction of 840 MW (4x50MW +

2X100MW + 4X110MW) plant of PTPS, Patratu, we want to visit the site for detailed Inspection on

…………………..

We agree to follow all the safety norms of Patratu Vidyut Utpadan Nigam Limited inside the plant during

inspection. We are made aware that the Inspection by our company at the site is to be completed by us

within a maximum of 03(three) working days but in any case before inspection closure date and time.

We are hereby submitting the Company PAN Card copy to “PVUNL, Patratu” prior to the site visit.

We are providing the details of the personnel who will be visiting the site on behalf of our company and

submitting their official photo identity proof.

(A) Name of the Company :

Address :

(B) Name of the Contact Person :

(C)

Address

Contact Telephone Nos:

:

:

(D) Mobile No. :

(E) FAX No. :

(F) E-Mail :

(G) Company PAN No. :

Page 7: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

7

I / WE CONFIRM THAT I / WE AM/ARE AWARE ABOUT THE T&C FOR INSPECTION AND THE

ITEMS ON OFFER.

The Name & Detail of Persons who will be visiting the site: 1.

2.

3.

4.

Yours faithfully for M/S

---------------------------------------

Signature of authorized person

With company seal Place: Date:

Note: This document after signature can be scanned & sent to the following email addresses along with the

other documents to be submitted.

1. [email protected]

2. [email protected]

3. [email protected]

Page 8: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

8

6. Brief History of Plant

6.1 Introduction :

Patratu Thermal Power Station (PTPS) was a coal-based thermal power plant located near Patratu town in Ramgarh

district in the Indian state of Jharkhand. The power plant was operated by the Jharkhand State Electricity Board.

PTPS comprises of coal fired Power Station with a total installed capacity of 840 MW comprising of 400 MW (4x50 MW

+ 2x100 MW) Russian units and 440 MW (4X110MW) Indian units. The plant had been constructed in four different stages.

The first stage consists of 4x50 MW (Units 1 to 4) and second stage consists of 2x100 MW (Units 5&6). Unit#5,6 have two

boilers and one TG set each. Hence, there are total 12 boilers and 10 TG sets. Unit # 1 to 6 were supplied by M/S Energy

Machine Export, USSR under trade agreement. Later, to meet the growing power demand of the state the Indian

Government installed four unit of 110 MW each (normal Indian site -1) in third and fourth stages leading to total installed

capacity of 840 MW. The third stage consists of 2x110 MW (Units 7& 8) and fourth stage consists of 2x110 MW (Units

9&10) supplied by BHEL. Six Russian- aided units were commissioned between 1966 and 1972 and the rest four units

were set up by Bharat Heavy Electricals between 1977 and 1986.

Due to environmental cum techno commercial reasons five units were already retired by CEA in past and remaining five

units were phased out w.e.f 24 th January 2017 and the same was retired by CEA. A MoU was signed between the Jharkhand

state and NTPC on May 3, 2015, to set up a 4,000MW project. For this, Patratu Vidyut Utpadan Nigam Ltd (PVUNL) was

formed as a joint venture company between the state's JBVNL and NTPC on October 15, 2015, where JBVNL holds 26

per cent stake, the power giant NTPC holds 74 percent stake.

6.2 Commissioning Dates & Unit Status

PTPS configuration along with status of its various units is as follows:

Table – 3: Status of Generating Units

Unit

No.

Rated

Capacity

(MW)

Derated

Capacity

(MW)

Date of Commissioning/

Make

Present Status

# 1 50 40 26thJune-1966Russian Under shut down

# 2 50 40 27thApril-1967 Russian Under shut down

# 3 50 40 16thOctober-1968 Russian Under shut down

# 4 50 40 30thOctober-1969 Russian Under shut down

# 5 100 90 31stMarch-1971 Russian Under shut down

# 6 100 90 31stMarch-1972 Russian Under shut down

# 7 110 105 31stAugust-1977 BHEL Under shut down

# 8 110 105 December-1979 BHEL Under shut down

# 9 110 - 30thMarch-1984 BHEL Under shut down

# 10 110 - 2nd

March-1986 BHEL Under shut down

The existing plant consists of 12 nos. boiler units and 10 nos. TG Units. It may be noted that boiler no. 5

& 6 is for TG unit 5. Similarly, boiler no. 7 & 8 is for TG unit 6.

Page 9: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

9

7. Sequence of Disposal

An indicative but not the exhaustive Sequence of Disposal is shown below. This may undergo change in case

of requirement based on further mutual agreeability between seller and Buyer.

Table – 4: Segment wise sequence of disposal

Segment

No.

Suggested

Target

timeline

Segment Description

1 5 Months ASH SLURRY PUMP HOUSES (BOTH RUSSIAN AND INDIAN), COOLING

TOWERS AND STORAGE TANKS, BOP, ESP OF UNIT 10, 9, 8 AND 7

Ash Handling System (Indian & Russian Side) including High Pressure Water

Pumps, Ash Slurry Pumps, LP ash water pump, Drain Pumps, Seal Water Pump, Make

Up Water Pump, Control Air Compressors, Dryer & Receiver Tank, Fluidizing Air

Blowers, Associated Pipes with fittings& valves

ESP for Unit-10,9,8&7including its hoppers, steel structure, ID Fan with motor, flue

gas duct from Boiler outlet flange to chimney & supporting structure with associated

piping and valves, ESP Control room, ESP Switchgears.

Fuel Oil System (Both Indian & Russian Side) including Unloading pumps, Storage

Tank, Transfer Pumps, FO heaters, Pump house building etc.

Cooling Tower for Unit-7, 8, 9 & 10 including Fan with motor, piping & valves

Misc. items including Tower Cranes, Gantry Cranes and Misc. Pump House. Russian

DM Plant.

Open Yard Material: Equipment dismantled from CHP area and Russian Cooling

Towers of Unit#1 to 6 are stored here.

2 5 Months STEAM GENERATORS OF UNIT # 10,9, 8 AND 7

Pressure Parts including Boiler Drum, Furnace Water Walls, Super heaters, Reheaters,

Economizers, Safety Valves.

Draft System including FD & PA Fan with motor, Air & Gas Ducts/Gates & Dampers

with supporting arrangement, Rotary Air Heater

Fuel preparation & Firing System including Coal conveyor & Gallery up to Boilers,

Coal Bunkers, Chain Feeders, Mills, Mechanical Separator, PF Pipes, Seal Air Fan,

Coal Burners, Oil Burners, Scanner Air Fan, Ignitor Air Fan, fittings & hangers

Misc. Items - Soot blowers (wall blower & LRSB), Bottom Ash hopper & associated

ash handling System, Misc. Tanks in SG area, External & Integral piping with fittings &

valves, Steel structure, gratings, walkways, Refractory etc. Conveyor Gallery up to

Boilers.

ESP system of Unit # 1 – 6, including its hoppers, steel structure, ESP Control room,

ESP Switchgears with associated piping and valves from Boiler outlet up to Chimney

inlet.

Page 10: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

10

3 5 Months BOILERS OF UNIT 6,5,4,3, 2 AND1

Pressure Parts including Boiler Drum, Furnace Water Walls, Super heaters,

Reheaters, Economizers, Safety Valves

Draft System including ID,FD& PA Fan with motor, Air & Gas Ducts/Gates

& Dampers with supporting arrangement, Rotary Air Heater

Fuel preparation & Firing System including Coal conveyor & Gallery up to

Boilers, Raw Coal Bunkers, Coal Scraper Feeders, Mills, Cyclones, Coal Dust

Feeder & Bunker, PF Pipes, Seal Air Fan, Coal Burners, Oil Burners, Scanner

Air Fan, Ignitor Air Fan, fittings & hangers

Misc Items - Soot blowers (wall blower & LRSB), Bottom Ash hopper &

associated ash handling System, Misc. Tanks in SG area, External & Integral

piping with fittings & valves, Steel structure, gratings, walkways, Refractory

etc.

4 4 Months CHIMNEYS (All four Chimneys); All loose items of TG Hall. Site Stores (viz.

MMD-6 , MMD-7 and MMD-9)

5 5 Months TG AUXILIARIES OF UNIT# 10, 9, 8 AND 7

Turbine , Lub Oil System (Turbine Main Oil Tank, Vapour Extraction Fan , Lubricant Oil Cooler , Main Oil Pump , Starting Oil Pump , Emergency Oil

Pump , Aux Oil Pump),Condensate and Feed Water System(Condensate Booster Pump, Condensate Extraction Pump) ,LP Heaters , Deaerator , Gland Steam

Condenser ,Boiler Feed Pumps , Oil Lubrication/Cooling System , HP Heaters,

Plant Compressed Air Systems –Service Air Compressor , Instruments Air Compressor , Air Receiver , Air Drying Unit, Main Turbo Generator Set (HP ,

IP , LP Cylinders) with Turbine Blades , Rotors , Generator Rotors , Stator

Excitation System , Seal Oil System , Bus Ducts , Steam & Water Piping, Valves , Ejectors etc.

6 5 Months TG AUXILIARIES OF UNIT # 6 , 5 , 4 , 3 , 2 AND 1

Turbine , Lub Oil System (Turbine Main Oil Tank, Vapor Extraction Pump, Lubricating Oil Cooler , Main Oil Pump , Starting Oil Pump , Emergency Oil

Pump, Aux Oil Pump),Condensate and Feed Water System(Condensate Booster Pump, Condensate Extraction Pump) ,LP Heaters , Deaerator , Gland

Steam Condenser ,Boiler Feed Pumps , Oil Lubrication/Cooling System , HP

Heaters , Plant Compressed Air Systems –Service Air Compressor , Instruments Air Compressor , Air Receiver , Air Drying Unit , Main Turbo

Generator Set (HP, IP LP Cylinders for Unit # 5 and 6 only. with Turbine

Blades, Rotors, Generator Rotors, Stator, Excitation System, Seal Oil system, Bus ducts, Steam & Water piping, Valves, Ejectors etc.

Note – 1. The disconnected electrical cables (of HT/LT Switchgear and Relays) after isolation of equipment in the MPH

shall not be removed unless instructed by EIC.

2. Agency to arrange for its own lighting arrangement for work in areas where light shall be required.

3. All items mentioned in Table – 2 shall be demolished and cleared after completion of demolition of

Segment 1 to Segment 6. Agency shall obtain clearance from the EIC for demolition of items mentioned in

Table – 2. Time period for the Segment 1 to 6 is 29 months. One month shall be assigned for dismantling of

the system/items included in initial exclusion i.e. Table-2.

Page 11: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

11

8. Detail of List of Items Under Disposal

Disclaimer: The items in the table/list and their indicated quantities/ weights are indicative only

based on approximate estimation. PVUNL can not be hold responsible for any mismatch.

Specifications shown in the table in the section are original specifications which might have

deteriorated over the period of operation. All participating vendors must visit the site and get

themselves satisfied before bidding for the same. All items lying outside plant isolation boundary, e.g.

Russian Cooling Towers, CHP, Railway siding, Russian oil facilities etc, are either dismantled or

being dismantled. All such items are kept or being kept in Open Storage Area which will be part of

the auction.

Table – 5: Summary of the items under disposal (Details given below)

SN PLANT MACHINERY DESCRIPTION APPROXIMATE

WEIGHT (MT)

A Steam Generators (Boiler No. 11 & 12) - Indian Side 12032

B Steam Generators (Boiler No. 9 & 10) - Indian Side 11734

C Ash Handling System (Indian side) 545

D Boilers with auxiliaries, electric & instrumentation for Boiler no. 1 to 8 25200

E Ash Handling System for Russian side 545

F Steam Turbine Generator Set (Unit 7, 8, 9 & 10) 3340

G Compressed Air facility 25

H Fuel oil unloading, transfer & storage system 130

I Steam Turbine Generator Set with Auxiliaries for Unit 1, 2, 3 & 4 1800

J Steam Turbine Generator Set with Auxiliaries for Unit 5 & 6 1630

K Fuel Oil System (Russian side) 155

L Material Handling Equipment 6765

M Movable equipment of CHP area 639

N Railway Lines, Weigh Bridges 4674

O Control & Instrumentation 124

P Water Supply System 2840

Q Air conditioning & Ventilation System 21

R Electrical equipment- Power generation & Evacuation system 7841

S Workshop Equipment 10

Sub Total 80050

T Steel Structure 20901

Total Approximate Weight 100951

Page 12: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

12

S.N. Equipment Details/ Broad Specifications Qty./Nos. Year of

Installation Approximate Weight

(MT)

Main Technological Equipment

A Steam Generators (Boiler No. 11 & 12) - Indian Side (with auxiliaries ,

electrics & instrumentation, Capacity : 375 t/hr of steam at 138 ata

pressure and 545 deg. C temperature)

2 1985 12032

1 Boiler Drum (1 no. each) (Design pressure : 158.2 kg / sq. cm) 1 per boiler 1985 included above

2 Furnace Dimensions (10.135 m width x 7.696 m depth) 1985 included above

3 Furnace Water Walls 1985 included above

4 Drum Safety Valves 1985 included above

5 Super heater Safety Valves 1985 included above

6 Wall Deslaggers (Medium of Flow : Steam from super heater header; Operating Pressure : 12.0 kg/cm2; Operating Temperature : 3300C; Drive Motor (Traverse/Rotary) : 0.56 / 0.05 kW)

40 per boiler 1985 included above

7 Long Retractable Soot Blower (Medium of Flow : Steam from super heater header, Operating Pressure : 9 - 12.0 kg/cm2, Operating Temperature : 3300C, Drive Motor (Traverse/Rotary) : 0.37 / 0.45 kW)

20 per boiler 1985 included above

8 ID Fan (Type : NDZV 28b, Capacity : 137.4 cu. m / sec, Static Pressure : 363 mm WC, Gas Temperature : 139 deg. C, Motor Rating : 800 kW (6.6 kV), Fan / Motor Weight : 46 T / 8.25 T)

3 per boiler 1985 included above

9 Rotary Air Heater (Type : Tri Sector, Regenerative, Heating surface : 8400 sq. m)

2 per boiler 1985 included above

10 FD Fan (Type : AN-13e6, Capacity : 58.6 cu. m / sec, Static Pressure : 458 mm WC, Motor Rating : 400 kW (6.6 kV), Fan / Motor Weight : 5.45 T)

2 per boiler 1985 included above

11 PA Fan (Type : NDFV - 20 b, Radial, Capacity : 41.2 cu. m / sec, Compression : 1273 mm WC, Motor Rating : 760 kW (6.6 kV), Fan / Motor Weight : 7.7 T /5.82 T)

2 per boiler 1985 included above

12 Coal Mills (Type : Bowl mill, Capacity : 18.4 t / hr, Motor Rating : 200 kW (6.6 kV))

6 per boiler 1985 included above

13 Seal Air Fan (Capacity : 153 t/hr, Head : 500 mm WC, Motor Rating : 37 kW (415 V))

2 per boiler 1985 included above

14 Coal Feeder (Type : Rotary Feeder, Capacity : 29.3 t / hr (max.), Motor Rating : 4 kW)

6 per boiler 1985 included above

15 Coal Burners 9 Burner Type : Corner, tilting, jet type, Rating : 4.5 T/hr (max. per burner)

24 per boiler 1985 included above

16 Oil Burners (Capacity per burner : 700 kg /hr, Number : 12 @ 4 per elevation)

12 per boiler 1985 included above

17 Scanner Air Fan (Type : Radial Backward Curved, Capacity : 2700 m3/hr, Pressure : 220 mmWC, Motor : 3.75 kW )

2 per boiler 1985 included above

18 Ignitor Air Fan (Type : Radial Backward, Curved, Capacity : 10000 m3/hr, Motor : 11 kW)

2 per boiler 1985 included above

19 Electrostatic Precipitator (Make : BHEL, No. of passes : 2, Gas flow : 222.2 Nm3 / sec, Efficiency : 98.5 %, Final dust concentration in the gas : 39.47 gms / Nm3, on ESP outlet / Emission level)

1 per boiler 1985 included above

Sub-total (A) 12032 MT

B Steam Generators (Boiler No. 9 & 10) - Indian Side (with auxiliaries , electrics & instrumentation, Capacity : 380 t/hr of steam at 139 ata pressure and, 540+5/(-)10 deg. C temperature)

2 1978 11734

1 Boiler Drum (Design pressure : 158.2 kg / sq. cm) 1 per boiler 1978 included above

2 Furnace Dimensions (10.135 m width x 7.696 m Depth) included above

3 Furnace Water Walls included above

4 Drum Safety Valves included above

5 Super heater Safety Valves included above

6 Soot Blowing System (Medium of Flow : Steam from super heater header, Operating Pressure : 20 ata, Operating Temperature : 320 to 3500C)

included above

7 ID Fan (Type : Axial with regulating inlet vanes, multi blade, impeller, outlet damper)

2 per boiler 1978 included above

8 Tubular Air Heater 1978 included above

Page 13: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

13

9 FD Fan (Type : Axial with regulating inlet vanes, multiblade, impeller, outlet damper)

2 per boiler 1978 included above

10 PA Fan (Type : Radial) 2 per boiler 1978 included above

11 Coal Mills (Type :Suction type drum & ball mill) 3 per boiler 1978 included above

12 Seal Air Fan 2 per boiler 1978 included above

13 Raw Coal Chain Feeder (Type : Chain type) 3 per boiler 1978 included above

14 Classifier 3 per boiler 1978 included above

15 Cyclones 3 per boiler 1978 included above

16 Pulverised Coal Bunkers 4 per boiler 1978 included above

17 Pulverised Coal Feeder (Type : Radial) 2 per boiler 1978 included above

18 Vapour Fan (Type : Radial) 3 per boiler 1978 included above

19 Coal Burners (Burner Type : Corner, tilting) 16 per boiler 1978 included above

20 Oil Guns (Number : 4 in side walls @ 2 in each side walls) 4 per boiler 1978 included above

21 Scanner Air Fan (Type : Radial Backward Curved) 2 per boiler 1978 included above

22 Electrostatic Precipitator (Make : BHEL, No. of passes : 2) 1 per boiler 1978 included above

Sub-total (B) 11734 MT

C Ash Handling System (Indian side) 1985 545

1 Fly ash hopper Included above

2 HP ash water pump (4W + 2S) 6 Included above

Capacity : 505 cu. m / hr

TDH : 105 mWC

Type : Vertical turbine

Motor Rating : 240 kW

3 LP ash water pump 2 Included above

Capacity : 350 cu. m / hr

TDH : 80

Type : Vertical turbine

Motor Rating : 120 kW

4 Ash ash slurry pump 6 Included above

Capacity : 885 cu. m / hr

TDH : 27m

5 Seal water pump 3 Included above

Capacity : 25 cu. m / hr

TDH : 165 mWC

Type : Horizontal centrifugal

Motor Rating : 18 kW

6 Drain pump 2 Included above

Capacity : 150 cu. m / hr

TDH : 8 mWC

Type : Vertical, Centrifugal

Motor Rating : 7.5 kW

7 Make Up Water Pump 3 Included above

Page 14: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

14

Type : Vertical Turbine

Capacity : 750 cu. m / hr

TDH : 15 mWC

Motor Rating : 50 kW

8 Air Blower 2 Included above

Capacity : 135 m3/hr

Head : 0.56 kg/cm2

Motor : 10 HP

9 Instrument Air Compressors 3 Included above

Capacity : 100 Nm3/hr @ 8 kg/cm2

10 Clinker Grinders 1 Included above

Grinder Speed : 54 rpm

Motor : 7.5

11 Rotary Feeder Included above

12 Miscellaneous piping & insulation Included above

Sub-total (C) 545

D Boilers with auxiliaries, electric & instrumentation for Boiler no. 1 to

8

8 1969 24000

Boiler make : V/O machine export USSR

Capacity : 220 t/hr of steam at 100 ata pressure and

540 deg. C temperature

1 Boiler Drum (1 no. each) 8 1969 Included above

Diameter : 1600 mm (ID) and wall thickness : 89mm

Design working pressure : 115 kg / sq. cm

Hydraulic test pressure : 172.4 kg / sq. cm

2 Furnace Dimensions 8 1969 Included above

Internal Dimensions : 7160 X 9792 mm

3 Economisers 8 1969 Included above

Type : Steaming

Heating Surface : 2015 m2

Tube Diameter : 32 X 3.5mm

Material : Steel 20

4 Superheaters 8 1969 Included above

a Radiant Superheater 8 1969

Tube Diameter : 32 X 3.5mm

Page 15: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

15

Material : Steel 20

b Semi - Radiant Superheater 8 1969

Heating Surface : 683 m2

Tube Diameter : 32 X 4 mm(outlet inlet screen)

Material : Steel 20

Tube Diameter : 38 X 4 mm(middle outlet screen)

Material : 12XMØ

c Convection Superheater 8 1969

Tube Diameter : 42 X 4.5 mm(first section along gas path)

Material : 12XMØ

Tube Diameter : 38 X 4 mm(Second section along gas path)

Material : 12XMØ

5 Soot Blowers for Superheaters 48 1969 Included above

Type : Long Travel Sootblowers(5 m)

Blow-off agent : Steam

Number : Six (6) per boiler

6 Soot Blowers for Waterwalls Included above

Type : Short Travel Sootblowers( 350 mm)

Blow-off agent : Steam

Number : Fourteen(14) per boiler

7 FD Fan 16 1969 Included above

Type : BAH -19

Capacity : 112600 cu. m /hr

Static Pressure : 406 mm WC

Motor Rating : 220 kW (6.6 kV)

Temperature : 30 Deg.C

Number : Two (2) per boiler

a ID Fan

Type : D - 2 x 2T

Capacity : 210000cu. m /hr

Static Pressure : 260 mm WC

Motor Rating : 260 kW (6.6 kV)

Page 16: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

16

Maximum Temperature of Flur Gas : 250 - 300 Deg.C

Number : Two (2) per boiler

8 Coal Mills 16 1969 Included above

Type : Ball Drum mill U6 M 287 / 470

Number of Mills : two (2) per boiler

Motor Power Outlet : 575kW (6.6 kV)

Speed : 745 rpm

Lubrication Pumps : Two (2) numbers geared type

Motor Power Outlet : 2.8kW

9 Mill Fans 16 1969 Included above

Type : BM - 50 /1000 - T6

Number : Two (2) per boiler

Capacity : 56000 cu. m /hr

Motor Capacity : 300 kW(6.6 kV), 1500 rpm

10 Coal Feeder 16 1969 Included above

Type : Raw Coal Scrapper Feeder CNY 700/7000

Number of each feeder : Two (2) per boiler

Capacity : 32 t / hr

Motor Rating : 7 kW (415 V)

11 Pulverised Coal Cyclone Ø 2350 16 1969 Included above

Number of cyclones per boiler : Two (2)

12 Pulverised Coal Seperator Ø 3420 16 1969 Included above

Number of Seperator per boiler : Two (2)

13 Pulversied Coal Feeder( Blade type) 48 1969 Included above

Flow : 8.5 t/hr

Number of Feeder per boiler : Six (6)

Motor rating: 3.4 kW , 220 V.D.C, 500-1500 rpm

14 Burners Included above

Page 17: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

17

a LDO Burners 48 1969

Numbers : Six (6) per boiler

Capacity per burner : 600 kg / hr

Pressure of LDO : 15-18 kg/cm2

b HFO Burners 48 1969

Capacity per burner : 500 kg / hr

Pressure of Steam : 15-17 kg/cm2

Medium for atomisation : Steam

c Coal Burners 48 1969

Type : Turbulent

Numbers : Six(6) per boiler located on side walls

15 Misc. Tanks, piping, hoisting facilities and Boiler External piping

including pipes, fittings, valves, hangers, etc.)

Lot 1969 1200

Sub-total (D) 25200

E Ash Handling System for Russian side 1969 545

1 Bottom Ash System: 1969 Included above

Scraper conveyor : Two (2)

Output of each scraper conveyor : 4.0 t/h

Scraper speed : 4.55 m/min

Power consumption of scraper conveyor : 4.5 kw

Type of crusher : Three roll type

Output of each crusher : 9.0t/h

Power consumption of crusher

: 4.5 kw

2 Fly Ash System 1969 Included above

Operation : pneumatically ash conveying by vacuum system

3 Ash Disposal System (Common System for all 1968 Included above

a. High Pressure Water Pumps: 8

Number : Eight(8), (4W + 4S)

Type : Vertical turbine type

Capacity of each pump : 625 cum/h

Head : 95 M

Page 18: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

18

Motor Rating : 230 kW

b. Seal water pump 3

Number : Three (3) , ( 1W+2SB)

Type : Horizontal centrifugal

Capacity of each pump : 25 cum/h

Head : 110 M

Motor Rating : 15 kW

c. Drain Pumps: 2

Number : Two (2)

Operation : automatically or Mannually

4 Ash Slurry Disposal Pumps (Common System for all Russian Units): 1969 Included above

a. Disposal Pumps 4

Number : Four (4)

Type : Horizontal centrifugal

Capacity of each pump : 1240 cum/h

Head : 56 M

b. Seal water pump 2

Number : Two (2)

Capacity of each pump : 200 lpm

Head : 40 M

c. Drain Pumps: 4

Number : Four ( 4 )

d. H.P. Flush Water Pumps (Common System for all Russian Units): 3

Nos : 3 ( 2W+1SB)

Type : 8DB

Capacity of each pump : 540 cum/h

Head : 94 M

e. L.P. Flush Water Pumps (Common System for all Russian Units): 3

Nos : Three ( 3 ) , ( 2W+1SB)

Type : 8HA6

Page 19: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

19

Capacity : 500 cum/h

Head : 39 mwc

5 Misc. Valves and fittings Lot

1969 Included above

6 Compressed Air Facility of fly ash dedusting system 1969 Included above

Instrument air compressor 3

Number : Three (3), (2W + 1S)

Capacity : 125 cu. m / hr

Discharge Pressure : 9 kg / sq. cm

Motor Rating : 22 kW

Sub-total (E) 545

F Steam Turbine Generator Set (Unit 7, 8, 9 & 10) with 4 Unit 1985 3340

Auxiliaries, Electrics, Controls & Instrumentation

Make : BHEL

Max. continuous rating : 110 MW each

Rated speed : 3000 rpm

Max Steam Pressure : 146 ata

Max. Steam Temperature : 545 deg. C

Condenser Vacuum : 0.093 kg/cm2 abs

Type : Three casing, condensing steam turbine

with reheating and non- regulated extractions

1 Turbine Auxiliaries 1985 included above

Lubrication System

a Main oil pump 1 per unit

Capacity : 4500 litres / min

Discharge Pressure : 10 - 12 kg / sq. cm

Speed : 3000 rpm

b Starting oil pump 2 per Unit

Capacity : 2000 L/min.

Discharge Pressure : 12 atg

Motor Rating : 95 kW

Page 20: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

20

c Emergency oil pump (AC / DC) 1 AC & 1 DC

Capacity : 800 L/min

Discharge Pressure : 3 mlc

Motor Rating (Both AC & DC) : 11 kW

d Auxiliary Oil Pump 1 per Unit

Type : Gear Pump

Capacity : 35 l/min

Pressure : 2 atg

Motor Rating : 1 kW

e Jacking Oil Pump 7 per Unit

Type : Single Flow Gear type

Capacity : 10.5 m3/hr

Pressure : 50 atg

Motor Rating : 30 kW

f Oil Cooler 3 per Unit

Type : shell & tube

Cooling water requirement : 120 cu. m / hr per cooler

Temperature rise of CW water : 4 deg. C

g Oil tank, Capacity : 12,500 Litres 1 per unit

h Turbine oil purification system 1 set per unit

Capacity : 4500 lph each

2 Starting Air Ejectors 1 per unit 1985 included above

Working steam pressure : 7 kg / sq. cm

Working steam temperature : 300 deg. C

Steam consumption : 2.4 T / hr

3 Main Ejector 1 per unit 1985 included above

Type : Two (2) stage, duplex, steam jet with condenser

Working steam pressure : 7 kg / sq. cm

Working steam temperature : 300 deg. C

Steam consumption : 1.6 T / hr

4 Condenser 2 per Unit 1985 included above

Make : BHEL

Page 21: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

21

Surface area : 3380 sq. m

No. of water passes : two

CW quantity : 15400 cu. m / hr for both Condenser

CW inlet temperature : 32.5 deg. C

Type : Surface

5 Condensate Extraction Pump 3 per Unit 1985 included above

Design Capacity : 160 T/h

Discharge head : 215 mWC

Motor Rating : 200 kW (6.6 kV)

6 Condensate Booster Pump 2 per Unit 1985 included above

Design Capacity : 200 cu. m / hr

Discharge head : 168 mWC

Motor Rating : 90 kW (415 kV)

7 External Vent Condenser 1 per Unit 1985 included above

Tube Surface : 90 sq. m

No. of Water Passes : Single

8 Boiler Feed Pump 2 per Unit 1985 included above

Capacity : 445 tph

Head : 177.85 atmg

Motor Rating : 4000 kW (6.6 kV)

9 Deaerator 1 per Unit 1985 included above

Type : Perforated tray type with external vent condenser

Design Pressure : 12 kg/cm2

Deaerator Design Temperature : 200 deg. C

FW Storage Tank Capacity : 80 cu. m (total)

10 LP Heaters 3 per Unit 1985 included above

11 HP Heaters 4 nos 1985 included

above

Sub-total (F) 3340

G Compressed Air Facility 1985 25

1 Control air compressor 4 1985 included above

Page 22: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

22

Make : K. G. Khosla Compressors Ltd.

Type : Two Stage Double Acting Reciprocating

Capacity : 201.6 cfm

Discharge Pressure : 7 kg / sq. cm

Motor Rating : 37 kW (415 V)

2 Service air compressor 3 1985 included above

Make : K. G. Khosla Compressors Ltd.

Type : Two Stage Double Acting Reciprocating

Capacity : 500 cfm (each)

Discharge Pressure : 8.4 kg / sq. cm

Motor Rating : 88.5 kW (415 V)

3 Air receiver 7 1985 included above

(4 nos for control air and 3 no. for service air)

Type : Vertical

Capacity : 4 cu. M (each)

Design pressure : 10.5 kg / sq. cm (g)

4 Air dryer 4 Nos. 1985 included above

Type : Dual Tower, semi- automatic with electrical reactivation using purge air open system

Capactity : 340 Nm3/hr

Sub-total (G) 25

H Fuel Oil Unloading, Transfer & Storage System 1985 130

Pump House # 1 (Near Unit 10) included above

1 Light Oil Pumps 2 Nos.

Type : Triple Screw, positive displacement

Capacity : 125 l/min, Del. Pressure : 23.0 kg/cm2

Motor : 8.0 kW (415 V)

2 Heavy Oil Pumps 2 Nos.

Type : Triple Screw, positive displacement

Capacity : 165 l/min, Del. Pressure : 26.0 kg/cm2

Page 23: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

23

Motor : 14.0 kW (415 V)

3 Fuel Oil Heaters 2 Nos.

Type : U-tube, hair-pin type

4 Fuel Oil Filters 2 Nos.

5 Fuel Oil Unloading Pumps

Type : Jacketed type sliding vane rotary pump

Capacity : 78 TPH, Disc. Pressure : 4.5 kg/cm2 2 Nos.

Motor : 22.5 kW

Capacity : 36 TPH, Disc. Pressure : 3.5 kg/cm2 2 Nos.

Motor : 18.5 kW

6 Light Oil Unloading Pumps 2 Nos.

Type : Centrifual, back pullout

Capacity : 1000 LPM, Disc. Pressure : 5.0 kg/cm2

Motor : 9.3 kW

Pump House # 2 (Near Unit 10) 1985 included above

1 Light Oil Transfer Pump 2 Nos.

Motor : 37 kW

2 Heavy Oil Transfer Pump 2 Nos.

Motor : 45 kW

3 Heavy Oil Unloading Pump 2 Nos.

Motor : 18.8 kW

4 Oil Filters 2 Nos.

5 Drain Pumps 3 Nos.

Fuel Oil Tanks 1985 included above

1 Heavy Oil Tanks (Cap. : 1000 kL) 2 Nos.

2 Light Oil Tanks (Cap. : 100 kL) 2 Nos.

3 Heavy Oil Tanks (Cap. : 3000 kL) 2 Nos.

4 Light Oil Tanks (Cap. : 700 kL) 2 Nos.

Page 24: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

24

5 Heavy Oil Tanks (Cap. 100 kL) - Near Unit # 8

1 Nos.

6 Light Oil Tanks (Cap. 100 kL) - Near Unit # 8 1 Nos.

Sub-total (H) 130

I Steam Turbine Generator Set with Auxiliaries for Unit 1,2,3 & 4 4 1969 1640

1 Steam Turbine 4 1969 Included above

Model : BK - 50-3 (Russian make , LMZ)

Speed : 3000 rpm

Steam flow at ESV - 192 t/h

Steam pressure (at ESV) - 90 abs, atm.

Steam temperature (at ESV) - 535 deg.C

Rated output - 50 MW

2 Lubrication System 1968 Included above

i. Main oil pump 4

Type : Shaft Driven

Speed : 3000 rpm

ii. Starting oil Pump, Type 6MC - 6 x10 4

Number : One (1) per Turbine

Capacity : 150 cu. m/hr

Head : 450 mwc

iii. Stand oil Pump(AC), Type 4 HD 6 4

Number : One (1) per Turbine

Capacity : 90 cu. m/hr

Head : 25 mwc

iv. Emergency oil pump (DC), Type 4 HD 6 4

Number : One (1) per Turbine

Capacity : 90 cu. m/hr

Head : 25 mwc

v. Oil Cooler 12

Type : Vertical shell & tube

Number : Three (3) Lub oil cooler per Turbine

Page 25: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

25

vi. Lub oil Tank (One number per Turbine) 4

3 Hogging Ejectors / Starting Ejector (One number per Turbine) 4 1968 Included above

Working steam pressure : 05 kg / sq. cm

Steam consumption : 1100 kg / hr

Capacity : 100 kg / hr

4 Main Ejector, Type En -3 -750 8 1968 Included above

Working steam pressure : 05 kg / sq. cm

Steam consumption : 750 kg / hr

Capacity : 2x100 % per Turbine

5 Double Pass Condenser 50KUC 7 4 1968 Included above

Surface area : 4000 sq. m

No. of water passes : Two (2) per Turbine

Type : Surface

6 Condensate Extraction Pump 10 KCD - 5 X3 8 1968 Included above

Numbers : Two (2) per Turbine

Design Capacity : 160 cu. m / hr

Discharge head : 123 mWC

Motor Rating : 125 kW, 415 V, 1000 rpm, squirrel cage induction motor

7 Deaerator AC - 2 4 1968 Included above

No. provided - One per Turbine

Deaerator capacity - 225 t/h

Tank storage capacity - 70 cu. m

Working pressure - 5.0 kg/cm2

Working temperature - 158 deg.C

No. of Perforated trays in deaerator - 8 nos.

8 Boiler Feed Pump 5U -10 8 1968 Included above

No. provided - Two per Turbine

Capacity of each - 270 m3/h

Suction pressure - 5 kg/cm2

Discharge pressure - 150 +/- 3% kg/cm2

Page 26: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

26

Pump speed - 2970 rpm

Pump motor kW - 2000 kW, 6.6 kV, 2980 rpm, Squirrel

cage

Coupling between pump and motor - Fluid coupling

i. LP Heater(LPH2, LPH3, LPH4,LPH5) 16 1968

ii LPH- 2 ( Built in Condenser 100KUC-7 ) per Turbine 4

Heating Surface area : 106 m2

iii LPH - 3, 4 & 5 (nH 90) per Turbine

12

Heating Surface area : 90 m2

9 HP Heater( HPH 6, 7 & 8 ) nB 170/180 per Turbine 12 1968 Included above

Heating Surface area : 170 m2

10 Misc. piping including pipes, fittings, valves, hangers, etc.) Lot 1968 160

Sub-total (I) 1800

J Steam Turbine Generator Set with Auxiliaries for unit 5 & 6 2 1972 1480

a. Steam Turbine 2 1972 Included above

Model - K-100-90 (Russian make, LMZ)

Speed : 3000 rpm

Steam flow at ESV - 368 t/h

Steam pressure (at ESV) - 90 abs, atm.

Steam temperature (at ESV) - 535 deg.C

Rated output - 100 MW

b. Lubrication System 1972 Included above

i Main oil pump 2

Type : Shaft Driven

Speed : 3000 rpm

ii. Starting oil Pump, Type 6MC - 6 x10 2

Page 27: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

27

Number : One (1) per Turbine

Capacity : 150 cu. m/hr

Head : 450 mwc

iii.

Stand oil Pump(AC), Type SHD 6 2

Number : One (1) per Turbine

Capacity : 126 cu. m/hr

Head : 30 mwc

iv.

Emergency oil pump (DC), Type SHD 6 2

Number : One (1) per Turbine

Capacity : 126 cu. m/hr

Head : 30mwc

v. Oil Cooler, type M - 60 10

Type : Vertical shell & tube

Number : Five (5) Lub oil cooler per Turbine

vi.

Oil Centrifuge 2

Number : One per Turbine

vii.

Lub oil Tank (One number) per Turbine 2

c. Hogging Ejectors / Starting Ejector (One number), Type EN- 1-1100-

1 per Turbine

2 1972 Included above

Working steam pressure : 06 kg / sq. cm

Steam consumption : 1100 kg / hr

Capacity : 100 kg / hr

d. Main Ejector, Type En -3 -750 4 1972 Included above

Working steam pressure : 06 kg / sq. cm

Steam consumption : 750 kg / hr

Capacity : 2x100 % per Turbine

e. Double Pass Condenser 100KUC 5 4 1972 Included above

Surface area : 4000 sq. m

No. of condenser : Two (2) per Turbine

Type : Surface

Page 28: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

28

f. Condensate Extraction Pump 10 KCD - 5 X3 6 1972 Included above

Numbers : Three (3) per Turbine

Design Capacity : 160 cu. m / hr

Discharge head : 123 mWC

Motor Rating : 125 kW, 415 V, 1000 rpm, squirrel cage induction motor

g. Deaerator 2 1972 Included above

No. provided - One per Turbine

Deaerator capacity - 400 - 450 t/h

Tank storage capacity - 90 cu. m

Working pressure - 5.0 kg/cm2

Working temperature - 150 deg.C

h. Boiler Feed Pump 5U -10 4 1972 Included above

No. provided - Three (3) per Turbine

Capacity of each - 270 m3/h

Suction pressure - 5 kg/cm2

Discharge pressure - 150 +/- 3% kg/cm2

Pump speed - 2970 rpm

Pump motor kW - 2000 kW, 6.6 kV, 2980 rpm, Squirrel

cage

Coupling between pump and motor - Fluid coupling

i. LP Heater(LPH2, LPH3, LPH4,LPH5) per Turbine

8 1972 Included above

i. LPH- 2 ( Built in Condenser 100KUC-5 ) per Turbine 2

Heating Surface area : 200 m2

ii. LPH - 3, Type nH-130 -6 per Turbine 2

Heating Surface area : 130 m2

iii. LPH - 4,5 Type NH-200-1 per Turbine

2

Heating Surface area : 200 m2

j. HP Heater( HPH 6, 7 & 8 ) NB 250 / 180 per Turbine

6 1972 Included above

Heating Surface area : 250 m2

Page 29: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

29

k. Misc. piping including pipes, fittings, valves,hangers,etc.) Lot 1972 150

Sub-total (J) 1630

K Fuel Oil System (Russian side) 1969 155

1 Unloading System

a For Russian unit 1 to 6 2 Included above

Number of pumps : Two (2)

Number of filters : Two (2)

b For Indian unit 7 to 10 3 Included above

Number of pumps : Three (3)

Number of filters :Three (3

c Common Transfer Pump for LDO & FO 3 Included above

Number : Three (3)

Filter : two (2)

Heater for FO fuel : Two (2)

d. Fuel Oil tanks 4 Included above

LDO Tanck : Three (3 )

Capacity : (2 X 500 kL) + (1 X

1000 kL)

FO Tank : One (1)

Capacity : 1 X 1000 kL

e. Transfer pipe from Russian to Indian side for fuel oil facilities Lot

1969 Included above

f Misc. piping including pipe, valves , fittings, etc. Lot

1969 Included above

Sub-total (K) 155

L Material Handling

Equipments

All equipment, machineries and auxiliaries, except

material handling equipment, of CHP area have been

dismantled and kept in the Open Storage Area

Sl.No. Equipment Details/ Broad

Specifications

Qty./Nos. Year of Installation Weight in tonnes

Page 30: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

30

1 Wagon Tippler-1 (WT-1) (Make:

Russian , maintained & renovated

by M/s HEC, Ranchi), Gear

Driven Rotary Tippler, Suitable

for 90T wagons, Min. No. of

Tipplings/Hour=8 -10 (Design),

2x30 KW

1 no. 1995

220

2 Belt Feeders BF-1 & 2, Cap.

250tph, BW 1400mm, Length

15m/15m, KW 13KW each

2 no. 1972 8

3 Conv. 6A/6B, Cap. 500tph, BW

1200mm, Belt Length 2 no. 1972

150m/150m, Belt Speed 1.89

m/s, Lift 7.4m, Motor 50KW each

78

4 Wagon Tippler-2 (WT-2) (Make:

Elecon), Gear Driven Rotaside

Tippler, Suitable for 90T wagons, Min. No. of Tipplings/Hour=8 -10

(Design), 1x65 KW

1 no. 1980

220

5 Vibrating Feeder (Make: M/s

Elecon), Capacity= 175 TPH,

Size=1500 mm(Approx.)x

900mm (Approx.)

3 no. 1972 7.5

6 Vibrating Feeder (Make: M/s

Elecon), Capacity= 175 TPH,

Size=1500 mm(Approx.)x

900mm (Approx.)

3 no. 1972 7.5

7 Conv. 9A/9B, Cap. 500tph, BW

1200mm, Belt Length 130m, Belt

Speed 1.89 m/s, Lift 6.73m, Motor

30KW each

2 no. 1972

67.6

8 Conv. 17, Cap. 500tph, BW

1200mm, Belt Length 66m, Lift

2m,

1 no. 1972 17

9 Conv. 7A/7B, Cap. 500tph, BW

1200mm, Belt Length 425m, Belt

Speed 1.89 m/s, Lift 8m, Motor

75KW each

2 no. 1972 221

10 Swing Feeders SF-1 & 2, (Make:

USSR), Capacity= 500TPH, Size=

3000

mm(Approx.)x 1500mm

(Approx.)

2 no. 1972 7

12 Conv. 8, Cap. 500tph, BW

1200mm, Belt Length 30m, Belt Speed 1.89 m/s, Lift

3.75m, Motor 14KW

1 no. 1972 7.8

13 Telescopic Conv. 5, Cap. 500tph,

BW 1200mm, Belt Length 180m,

Belt Speed 1.89 m/s, Lift 22m,

Motor 75 KW

1 no. 1972

46.8

14 Telescopic Chute, Make:

Elecon 1 no. 1972 7

15 Conv. 1A/1B, Cap. 500tph, BW

1200mm, Belt Length 360m, Belt

Speed 1.89 m/s, Lift 3m, Motor

55KW each

2 no. 1972 94

16 Conv. 2A/2B, Cap. 500tph, BW

1200mm, Belt Length 240m, Belt

Speed 1.89 m/s, Lift 25.4m, Motor

75KW each

2 no. 1972

62.4

Page 31: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

31

17 Hammer Mill Crusher (Make:

Russian), Capacity= 500

(Rated)/750 (Design), 2x900

KW

2 no. 1972 50

18 Conv. 3A/3B, Cap. 500tph, BW

1200mm, Belt Length 530m, Belt

Speed 1.89 m/s, Lift 46.3m, Motor

100KW each

2 no. 1972

275.6

19 Conv. 4A/4B, Cap. 500tph, BW

1200mm, Belt Length 600m, Belt

Speed 1.89 m/s, Lift 2.5m, Motor

125KW each

2 no. 1972

312

20

Motorised Travelling Tripper on

Conv. 16A/16B (Make: Elecon),

Capacity=500 TPH

4 no. 1989 80

21 Conv. 16A/16B, Cap. 500tph,

BW 900mm, Belt Length 475m, Belt Speed 2.43 m/s, Lift 14m,

Motor 55KW each

2 no. 1972

190

22 Motorised Travelling Tripper on

Conv. 16A/16B (Make: Elecon),

Capacity=500 TPH

2 no. 1989 40

23 Wagon Tippler-3 (WT-3) (Make: HEC), Gear Driven Rotary

Tippler, Suitable for 90T wagons,

Min. No. of Tipplings/Hour=8 -10

(Design), 2x 75 KW

1 no. 1987

230

24 Vibrating Feeder (Make: M/s Elecon), Capacity= 175 TPH,

Size=1500 mm(Approx.)x

900mm (Approx.)

3 no. 1972 7.5

25 Vibrating Feeder (Make: M/s

Elecon), Capacity= 175 TPH,

Size=1500 mm(Approx.)x

900mm (Approx.)

3 no. 1972 7.5

26 Conv. 22A/22B, Cap. 500tph, BW

1200mm, Belt Length 130m, Belt

Speed m/s, Lift 5m

2 no. 1972 67.6

27 Conv. 18A/18B, Cap. 500tph, BW

1200mm, Belt Length 45m, Belt

Speed m/s, Lift 0.0m

2 no. 1972 23.4

28 Vibrating Feeder (Make: M/s

Elecon), Capacity= 175 TPH,

Size=1500 mm(Approx.)x

900mm (Approx.)

2 no. 1972 5

29 Conv. 25, Cap. 300tph, BW 900mm, Belt Length 206m, Belt Speed m/s, Lift 21.0m,

1 no. 1972 41.2

30 Conv. 26, Cap. 300tph, BW 900mm, Belt Length 400m, Belt Speed m/s, Lift 9.5m,

1 no. 1972 104

31 Conv. 19A/19B, Cap. 500tph,

BW 1200mm, Belt Length

500m, Belt Speed m/s, Lift 28m,

2 no. 1972 104

32 Cross Belt Magnetic Separator 2 no. 1972 17

33 Conv. 20A/20B, Cap. 500tph, BW 1200mm, Belt Length

200m, Belt Speed m/s, Lift 0.0m

2 no. 1972 104

34 Vibrating Feeder (Make: M/s

Elecon), Capacity= 175 TPH,

Size=1500 mm(Approx.)x

900mm (Approx.)

3 no. 1972 7.5

Page 32: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

32

35 Vibrating Feeder (Make: M/s

Elecon), Capacity= 175 TPH,

Size=1500 mm(Approx.)x

900mm (Approx.)

3 no. 1972 7.5

36 Conv. 13A/13B, Cap. 500tph, BW

900mm, Belt Length 400m, Belt

Speed 2.43m/s, Lift

5.4 m,Motor 45KW each

2 no. 1972

160

37 Conv. 14A/14B, Cap. 500tph, BW

900mm, Belt Length 225m, Belt

Speed 2.43m/s, Lift

28.2 m,Motor 67KW each

2 no. 1972

90

38 Cross Belt Magnetic Separator,

Make: Power Build Ltd, Model:

OV 8.90/100-P, KW rating: 25.8,

Supply voltage: 110AC

2 no. 1972

17

39 Ring Granulator, Cap. 500tph,

Size separation (-)25mm, Motor KW 525 each

2 no. 1972 60

40 Vibrating Screens (Make: M/s

Elecon), Capacity= 500 TPH,

Size=3500 mm(Approx.)x

2000mm (Approx.),Motor KW 30KW each

2 no. 1972

12

41 Conv. 15A/15B, Cap. 500tph, BW 900mm, Belt Length 300m, Belt

Speed 2.43m/s, Lift

42.4 m,Motor 2x 55KW each

2 no. 1972

120

42 Conv. 23A/23B, Cap. 500tph, BW 900mm, Belt Length 30m, Lift 4.5 m,Motor

2 no. 1972 12

43 Cross Belt Magnetic Separator,

Make: Power Build Ltd, Model:

OV 8.90/100-P, KW rating: 25.8,

Supply voltage: 110AC

2 no. 1972

17

44 Conv. 24A/24B, Cap. 500tph, BW 900mm, Belt Length 200m,

Lift 2.5 m

2 no. 1972 80

45 Conv. 10, Cap. 750tph, BW 1200mm, Belt Length 1350m,

Belt Speed 2.56m/s, Lift 9.2

m,Motor 2x 90KW each

1 no. 1972

351

46 Stacker Cum Reclaimer, Stacking Cap. 500tph

&Recalim Cap. 750tph

1 no. 1972 350

47 Conv. 11, Cap. 750tph, BW 1050mm, Belt Length 1350m,

Belt Speed 2.36m/s, Lift 9.2

m,Motor 2x 90KW each

1 no. 1972

283.5

48 Vibrating Feeder (Make: M/s

Elecon), Capacity= 187.5 TPH,

Size=1500 mm(Approx.)x 900mm

(Approx.)

4 no. 1972 10

49 Conv. 21, Cap. 750tph, BW 1200mm, Belt Length 160m, Lift

3m

1 no. 1972 42

50 Vibrating Feeder (Make: M/s Elecon), Capacity= 187.5 TPH,

Size=1500 mm(Approx.)x 900mm

(Approx.)

4 no. 1972 10

51 Conv. 12 with a fixed tripper, Cap. 750tph, BW 1050mm, Belt Length

1330m, Belt Speed 2.36m/s, Lift

5m, Motor 2x55 KW each

1 no. 1972

280

Page 33: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

33

52 Transfer Chute for conveying

system at Russian Unit 1 lot 1972 100

53 Transfer Chute for conveying

system at Indian Unit 1 lot 1972 150

54 Counter weight, Material: Cast Iron

1 lot 1972 200

55 Sluice Gate Maintenance Equipment, Cap. 7.1t

1 no. 1972 4

56 25/5 t EOT Crane, Span 10.5m 1 no. 1972 15

57 10t M/Hoist 9 no. 1972 18

58 10t E/Hoist 2 no. 1972 4

59 5t M/Hoist 2 no. 1972 2.4

60 5t M/Hoist 2 no. 1972 2.4

61 5t M/Hoist 4 no. 1972 4.8

62 5t M/Hoist 4 no. 1972 4.8

63 10t M/Hoist 2 no. 1972 4

64 DG EOT Crane Cap. 100/20t

Span 22.5m, Top of Rail 17.1m,

Travel 600m (approx.) Make:

Russian

Rail size: CR 120

2 no. 1972

230

65 DG EOT Crane Cap. 60/15t

Span 22.5m, Top of Rail 17.1m, Travel 600m (approx.) Make:

Garlic Engineering Pvt Ltd

Rail size:CR 120

1 no. 1972

80

66 Gantry Crane Cap. 10t

(approx.)

Span 25m, Travel 200m (approx.) Rail size:CR 120

2 no. 1972

50

67 Rail for Gantry Crane, Travel

Length=200 (approx.), Sapn

25m (approx.), rail Size: CR

120

1 lot 1972 47

68 Tower Crane Cap.

40t (Approx.)

Span 25m, Travel 200m (approx.) Rail size: CR 120

2 no. 1972

850

69 Rail for Tower Crane, Travel

Length=200 (approx.), Sapn

25m (approx.), rail Size: CR

1 lot 1972 47

Crane (Chain mounted), Cap. -

100t (Approx) Make : TATA

P&MH

1 no. 1971 150

82 Drill Machine 2 no. 1972 24

83 Vulcanizing Machine (1 nos. For 900mm BW, 1 no. for 1050mm BW & 2nos. For

4 no. 1972 -

84 Gear Box, Russion Make 10 no. 2000 25

85 Conveyor Belt, BW 1200 mm, 6Ply N/N 6/2.5 Top/Bottom

800 no. 2014 -

86 Compressor 1 no. 1972 10

87 Welding Machine 4 no. 1972 15

Page 34: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

34

88 Screw Jack 2 no. 1972 20

89

Hydo Mechanical

Jack(3x50t,4x150t,5x100t) 12 no. 1972 60

90 New Conveyor Idlers 250 no. 2014 7.5

Sub-total (L) 6765.2

M Movable Equipment in

CHP Area

1 BD-155 BEML DOZER- 2 2002 51.84

2 BD-80 BEML DOZER- 2 2006 42.2

3 TIPLLING TRUCK-Dumper, cap. 20t (approx.), Make :

TATA

3 2000 75

4 TATA P&H CRANE 1 1970 150

5 COLES CRANE- 1 2002 15

6 MARSHAL CRANE- 1 1995 50

7 VENTRA LOCO- 1 2000 66

8 SAN LOCO- 1 2003 90

9 EXCAVATOR BEML - 1 1998 22

10 PAYLOADER(BEML)- 1 2006 42

11 ELECTRIC WAGON

PUSHER

1 2003 35

Sub-total (M) 639.04

N Railway Lines,

weigh bridges

1 Railway track

(90 lbs rail, cst-9/steel sleppers)

a Private siding from Patratur 2 kms 1968

station to Plant gate 1 km 1998

Rails (300 T) 300

Sleepers ( 330T)(cast iron -

Steel)

330

b Plant Railway Yard and pre- 18 kms 1968

tippling yard 2 kms 1998

Rails (1800T) 1800

Sleepers (2200T) 2200

(1.5 km track for WT-3 added in

1998)

(90 lbs rail, cst-9/steel sleppers)

2 Weighbridges

a 120T capacity in-motion railway

1 no. 1965 6

weighbridge (pit type)

b 120 T capacity in-motion rail 1 no. 1998 6

weighbridge (pit type)

Page 35: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

35

c 20T capacity road weighbridge 1 no. 1970 8

(6 x 3 m platfor pit type)

d 40T capacity road weighbridge 1 no. 1970 12

12 x 3 m platform pit type)

e 40T capacity road weighbridge 1 no. 1998 12

12 x 3 m platform pit type)

Sub-total (N) 4674

O Control &

Instrumentation

1 Unit-1

a DCS Hardware : Make

Honeywell Experion PKS

V.4.1

1 Lot 2007 5.2

DCS Software 1 2007

Operator Work station 5 2007

Engineering Work Station 1 2007

Server 2 2007

A4 Colour Laser Printer 1 2007

A4 Black & white laserjet

Printer

3 2007

GPS Based Master Clock

System Make : SERTEL

1 set 2007

SER with dot natrix printer 1 2007

Alarm Annunciation system 1 set 2007

TSI Panel -Rockwell

(Allenbradley)

2007

b

Pressure/DP Transmitter Make :Fuji

70 2007

12 point chartless recorder 5 2007

Oxygen Analyser 1 2007

Electrical transducer 57 2007

Pressure/DP Gauges 100 2007

Temperature Gauges 75 2007

Level Gauges 10 2007

Pressure/ DP switches 20 2007

Temperature switches 15 2007

RTD & Thermocouple 150 2007

Automanual Station 15 2007

Level Switches 15 2007

Temperature Transmitters 150 2007

Analog meter 2 2007

Analog Voltmeter 2 2007

Bargraph Indicators 10 2007

Page 36: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

36

MW Meter 1 2007

Power Factor Meter 1 2007

Frequency Meter 1 2007

MVAR Meter 1 2007

Electronic Drum level

Indicator-12 Electrode

1 2007

Single Channel Digital

Indicators

4 2007

UPS with Lead Acid Battery

2x25KVA

1 set 2007

Instrumentation Cable 1 lot 2007

Control Cables 1 lot 2007

Eraction Hardware : 1 lot 2007 2.5

a) Cable Tray 2007

b)Junction Box 2007

c)Fittings 2007

d)Pipes 2007

e) Cable Accessories 2007

UCP Panel and Hardware

Console

1 lot 2007 1

Electric Actuators 1 lot 2007 4

Furniture for DDCMIS 1 lot 2007 0.05

Mandatory Spares for C&I

Total a+b 12.75

c Control room AC Package

units 15 Ton Capacity

0.3

Total a+b+c 13.05

2 Unit # 2 In Ton

a DCS Hardware : Make Honeywell Experion PKS

V.4.1

1 Lot 2007 5.2

DCS Softare 1 2007

Operator Work station 5 2007

Engineering Work Station 1 2007

Server 2 2007

A4 Colour Laser Printer 1 2007

A4 Black & white laserjet Printer

3 2007

GPS Based Master Clock

System : Make SERTEL

1 set 2007

SER with dot natrix printer 1 2007

Alarm Annunciation system 1 set 2007

TSI Panel : Rockwell (AB) 2007

b Pressure/DP Transmitter Fuji/Honeywell

70 2007

Page 37: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

37

12 point chartless recorder 5 2007

Oxygen Analyser 1 2007

Electrical transducer 57 2007

Pressure/DP Gauges 100 2007

Temperature Gauges 75 2007

Level Gauges 10 2007

Pressure/ DP switches 20 2007

Temperature switches 15 2007

RTD & Thermocouple 150 2007

Automanual Station 15 2007

Level Switches 15 2007

Temperature Transmitters 150 2007

Analog meter 2 2007

Analog Voltmeter 2 2007

Bargraph Indicators 10 2007

MW Meter 1 2007

Power Factor Meter 1 2007

Frequency Meter 1 2007

MVAR Meter 1 2007

Electronic Drum level

Indicator-12 Electrode

1 2007

Single Channel Digital

Indicators

4 2007

UPS with Lead Acid Battery 2x25KVA DB electronics

1 set 2007

Instrumentation Cable 1 lot 2007

Control Cables 1 lot 2007

Erection Hardware : 1 lot 2007 2.5

a) Cable Tray 2007

b)Junction Box 2007

c)Fittings 2007

d)Pipes 2007

e) Cable Accessories 2007

UCP Panel and Hardware Console

1 lot 2007 1

Electric Actuators 1 lot 2007 4

Furniture for DDCMIS 1 lot 2007 0.05

Total a+b 12.75

c Control room AC Package

units 15 Ton Capacity

0.3

Total a+b+c 13.05

3 Unit # 3 In Ton

a Control desk 1 lot 1960 4

Page 38: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

38

b Pressure/DP Transmitter 35 2007

12 point chartless recorder 0 2007

Oxygen Analyser 0 2007

Pressure/DP Gauges

Temperature Gauges

Level Gauges

Pressure/ DP switches

Temperature switches

RTD & Thermocouple

Level Switches 15 2007

Temperature Transmitters 150 2007

Analog meter 2 2007

Analog Voltmeter 2 2007

Bargraph Indicators 10 2007

MW Meter 1 2007

Power Factor Meter 1 2007

Frequency Meter 1 2007

MVAR Meter 1 2007

Electronic Drum level

Indicator-12 Electrode

1 2007

Total a+b 4

4 Unit # 4

a DCS Hardware: Make ABB

Symphony Harmony BRC

1 Lot 2008 5.2

DCS Softare 1 2008

Operator Work station 5 2008

Engineering Work Station 1 2008

Server 2 2008

A4 Colour Laser Printer 1 2008

A4 Black & white laserjet

Printer

3 2008

GPS Based Master Clock

System :Make Sertel

1 set 2008

SER with dot natrix printer 1 2008

Alarm Annunciation system 1 set 2008

TSI Panel : AB Penel view 2008

b Pressure/DP Transmitter 70 2008

12 point chartless recorder 5 2008

Oxygen Analyser 1 2008

Electrical transducer 57 2008

Pressure/DP Gauges 100 2008

Temperature Gauges 75 2008

Page 39: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

39

Level Gauges 10 2008

Pressure/ DP switches 20 2008

Temperature switches 15 2008

RTD & Thermocouple 150 2008

Automanual Station 15 2008

Level Switches 15 2008

Temperature Transmitters 150 2008

Analog meter 2 2008

Analog Voltmeter 2 2008

Bargraph Indicators 10 2008

MW Meter 1 2008

Power Factor Meter 1 2008

Frequency Meter 1 2008

MVAR Meter 1 2008

Electronic Drum level Indicator-12 Electrode

1 2008

Single Channel Digital

Indicators

4 2008

UPS with Lead Acid Battery 1 set 2008

Instrumentation Cable 1 lot 2008

Control Cables 1 lot 2008

Eraction Hardware : 1 lot 2008 2.5

a) Cable Tray 2008

b)Junction Box 2008

c)Fittings 2008

d)Pipes 2008

e) Cable Accessories 2008

UCP Panel and Hardware

Console

1 lot 2008 1

Electric Actuators 1 lot 2008 4

Furniture for DDCMIS 1 lot 2008 0.05

DCS ABB make comm.card spare

1no.

Actuactor ABB make spare 1 lot 2014

Fuji make Transmitter spare 1 lot 2014

Lab Instruments

Mandatory Spares for C&I

Total (a+b) 12.75

c Control room AC Package units 15 Ton Capacity

0.3

Total (a+b+c) 13.05

5 Unit # 5 In Ton

a Control desk 1 lot 1960 4

Page 40: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

40

b Pressure/DP Transmitter 35 1960

12 point chartless recorder 0 1960

Oxygen Analyser 0 1960

Pressure/DP Gauges

Temperature Gauges

Level Gauges

Pressure/ DP switches

Temperature switches

RTD & Thermocouple

Level Switches 15 1960

Temperature Transmitters 150 1960

Analog meter 2 1960

Analog Voltmeter 2 1960

Bargraph Indicators 10 1960

MW Meter 1 1960

Power Factor Meter 1 1960

Frequency Meter 1 1960

MVAR Meter 1 1960

Electronic Drum level

Indicator-12 Electrode

1 2007

Total (a+b) 4

6 Unit # 6 Russian

a Russian control desk 1lot 1960 4

TSI Panel 1 set 2013 1

b Pressure/DP Transmitter 70 2007

12 point chartless recorder 5 2007

Oxygen Analyser 1 2007

Electrical transducer 57 2007

Pressure/DP Gauges 100 2007

Temperature Gauges 75 2007

Level Gauges 10 2007

Pressure/ DP switches 20 2007

Temperature switches 15 2007

RTD & Thermocouple 150 2007

Automanual Station 15 2007

Level Switches 15 2007

Temperature Transmitters 150 2007

Electronic Drum level

Indicator-12 Electrode

1 2007

Single Channel Digital

Indicators

4 2007

Instrumentation Cable 1 lot 2007

Control Cables 1 lot 2007

Page 41: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

41

Eraction Hardware : 1 lot 2007 2.5

a) Cable Tray 2007

b)Junction Box 2007

c)Fittings 2007

d)Pipes 2007

e) Cable Accessories 2007

UCP Panel and Hardware Console

1 lot 2007 1

Electric Actuators 1 lot 2007 4

Total (a+b) 12.5

7 Unit # 7

a Control desk 1 lot 1977-78 4

SCADA : Siemens PDCS 1 set 1

b Pressure/DP Transmitter 35 1977-78

12 point chartless recorder 0 1977-78

Oxygen Analyser 0 1977-78

Pressure/DP Gauges

Temperature Gauges

Level Gauges

Pressure/ DP switches

Temperature switches

RTD & Thermocouple

Level Switches 15 1977-78

Temperature Transmitters 150 1977-78

Analog meter 2 1977-78

Analog Voltmeter 2 1977-78

Bargraph Indicators 10 1977-78

MW Meter 1 1977-78

Power Factor Meter 1 1977-78

Frequency Meter 1 1977-78

MVAR Meter 1 1977-78

Electronic Drum level

Indicator-12 Electrode

1 1977-78

Total (a+b) 5

8 Unit # 8

a Control desk 1 lot 1977-78 4

b Pressure/DP Transmitter 35 1977-78

12 point chartless recorder 0 1977-78

Oxygen Analyser 0 1977-78

Page 42: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

42

Pressure/DP Gauges

Temperature Gauges

Level Gauges

Pressure/ DP switches

Temperature switches

RTD & Thermocouple

Level Switches 15 1977-78

Temperature Transmitters 150 1977-78

Analog meter 2 1977-78

Analog Voltmeter 2 1977-78

Bargraph Indicators 10 1977-78

MW Meter 1 1977-78

Power Factor Meter 1 1977-78

Frequency Meter 1 1977-78

MVAR Meter 1 1977-78

Electronic Drum level Indicator-12 Electrode

1 2007

Total (a+b) 4

9 Unit# 9

a BHEL : maX DNA DCS

BMSS/FSSS -Flam Scaner Panel CJF07

1 set 2010 0.3

BMSS/FSSS -MFT/Purge Panel CJF01,CJF02 CJF03

1 set 2010 0.9

BMSS/FSSS - Oil AB and

Coal A&B CJF23&24,

1 set 2010 0.9

BMSS/FSSS - Oil CD and

Coal C&D CJF25&26,

CAF21

1 set 2010 0.9

BMSS/FSSS - Oil EF and Coal

E&D CJF27&28,

1 set 2010 0.9

SADC/APRDS Panels

CAF16 & CAF17

1 set 2010 0.9

SBC Panels CJF20 & CJF21 1 set 2010 0.9

b TG C&I Package

Turbine Protection panels

CJJ05 &CJJ06

1 set 2010 0.9

Functional group panels

CRE01 &CRE02

1 set 2010 0.9

Functional group panels

CRE03 &CRE04

1 set 2010 0.9

Functional group panels CRE05 &CRE06

1 set 2010 0.9

Functional group panels

CRE07 &CRE08

1 set 2010 0.9

Page 43: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

43

Functional group panels

CRE009 &CRE10

1 set 2010 0.9

Functional group panels CRE11&CRE12

1 set 2010 0.9

Functional group panels CRE13 &CRE14

1 set 2010 0.9

Functional group panels

CRE15 &CRE16 common

for Unit 9&10

1 set 2010 0.9

Interposing relay panel CTE01

1 2010 0.3

Interposing relay panel CTE02

1 2010 0.3

Emergency Backup

Panel/Desk

1 2010 0.9

Network Panel For HMI DCS NWPC01

1 set 2010 0.3

max DNA Eng work station (EWS)without monitor

2 nos. 2010

max DNA operating work

station (OWS)without monitor

4nos. 2010

max DNA operating work

station (OWS) for LVS

1 no 2010

max DNA storian work

station without monitor

1 2010

19" TFT for

EWS/OWS/Storian

7 2010

Inkjet printer A4 Colour 2010

Dot matrix printer with server

1 set 2010

Laser printer A4 B/W 1 2010

UTP cable 30 2010

c Field Instruments

Pressure Transmitters 58 2010

Differential Pressure Transmitters

47 2010

Pressure Switches 31

Temp Switch 8

Differential Pressure Switch 39

Flow switches 1

Pressure gauge 75

Thermocouple & RTD 120

High Energy Discharge Ignitor

12set

Pneumatic actuator for SADC

52 nos.

SADC dampers assembly 4nos.

Power cylinder for Burner tilting

4nos.

Coal Valve at inlet to RC feeder

Air Cooled oil gun assembly 12nos.

Page 44: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

44

Switch Box for wall blowers 39nos

Pneumatic corner nozzle valve

1 set

PD Meter for HFO/LFO 3nos

Vibration monitoring system

for PA Fan

1 set

Displacement type level

Transmitter

2 2010

Hand Held Heart communicator

2010

Hart Management system

HMS

2010

IL kota pneumatic actuator 27

UPS system 2x50 KVA 1 set 2010

Battery for UPS 2010

Instrumentation cable 2010 3

Thermocouple Compensating

cable

2010 2

Cable Tray 1 set 2010 2

Master Slave GPS common for

unit 9 &10

1 set 2010 0.3

Condensate pot 1 set 2010 0.5

Erection hardware 1 set 2010 2

d SWAS System indigenous

SWAS wet Panel 2010 0.7

SWAS dry panel 2010 0.5

SWAS imported - Analysers 2010

Conductivity Analyser 8 2010

Dissolve Oxygen analyser 2 2010

Hydrazine Analyser 1 2010

Silica Analyser 1 2010

pH Analyser 3 2010

e TSI

Trbosupervisory system

imported

1 set 2010 0.4

Turbine Supervisory system

Indigenous portion

1 set 2010 0.3

Furniture for Pc & Printers 1 set 2010 0.5

Large video Screen (LVS) 1 no. 2010 0.3

HMI Control Desk 1 set 2010 0.2

Public Address System 1 set 2010 0.05

Temperature element RTD/TC

139 2010

f Oxygen analyser O2 1 set 2010

Flue gas analyser CO 2010

Smoke density Analyser 2010

Total (a+b+c+d+e+f) 28.35

Page 45: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

45

10 Unit# 10

a BHEL : maX DNA DCS

BMSS/FSSS -Flam Scanner

Panel CJF07

1 set 2010 0.3

BMSS/FSSS -MFT/Purge

Panel CJF01,CJF02 CJF03

1 set 2010 0.9

BMSS/FSSS - Oil AB and Coal A&B CJF23&24,

1 set 2010 0.9

BMSS/FSSS - Oil CD and

Coal C&D CJF25&26,

CAF21

1 set 2010 0.9

BMSS/FSSS - Oil EF and

Coal E&D CJF27&28,

1 set 2010 0.9

SADC/APRDS Panels

CAF16 & CAF17

1 set 2010 0.9

SBC Panels CJF20 & CJF21 1 set 2010 0.9

b TG C&I Package

Turbine Protection panels

CJJ05 &CJJ06

1 set 2010 0.9

Functional group panels

CRE01 &CRE02

1 set 2010 0.9

Functional group panels

CRE03 &CRE04

1 set 2010 0.9

Functional group panels

CRE05 &CRE06

1 set 2010 0.9

Functional group panels

CRE07 &CRE08

1 set 2010 0.9

Functional group panels

CRE009 &CRE10

1 set 2010 0.9

Functional group panels CRE11&CRE12

1 set 2010 0.9

Functional group panels

CRE13 &CRE14

1 set 2010 0.9

Functional group panels

CRE15 &CRE16 common for Unit 9&10

NIL 2010 0

Interposing relay panel CTE01

1 2010 0.3

Interposing relay panel CTE02

1 2010 0.3

Emergency Backup Panel/Desk

1 2010 0.9

Network Panel For HMI DCS NWPC01

1 set 2010 0.3

max DNA Eng work station

(EWS)without monitor

2 nos. 2010

max DNA operating work

station (OWS)without monitor

4nos. 2010

max DNA operating work station (OWS) for LVS

1 no 2010

max DNA storian work station without monitor

1 2010

19" TFT for EWS/OWS/Storian 7 2010

Page 46: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

46

Inkjet printer A4 Colour 2010

Dot matrix printer with server 1 set 2010

Laser printer A4 B/W 1 2010

UTP cable 30 2010

c Field Instruments

Pressure Transmitters 58 2010

Differential Pressure Transmitters

47 2010

Pressure Switches 31

Temp Switch 8

Differential Pressure Switch 39

Flow switches 1

Pressure gauge 75

Thermocouple & RTD 120

High Energy Discharge Ignitor

12set

Pneumatic actuator for SADC

52 nos.

SADC dampers assembly 4nos.

Power cylinder for Burner

tilting

4nos.

Coal Valve at inlet to RC

feeder

Air Cooled oil gun assembly 12nos.

Switch Box for wall blowers 39nos

Pneumatic corner nozzle

valve

1 set

PD Meter for HFO/LFO 3nos

Vibration monitoring system

for PA Fan

1 set

RC damper IL make 33 2011

Feed water scoop equipment 2nos 2012

SD torque Actuator 10nos 2012

Auma make actuator 11nos 2011

Electrical actuator 23nos 2011

Pneumatic actuator

Fisher/ESME England

11nos.

Simens make valve & damper MCC module

IL kota pneumatic actuator 29

Displacement type level

Transmitter

2 2010

Hand Held Heart

communicator

2010

Hart Management system

HMS

2010

UPS system 2x50 KVA 1 set 2010

Battery for UPS 2010

Instrumentation cable 2010 3

Page 47: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

47

Thermocouple Compensating

cable

2010 2

Cable Tray 1 set 2010 2

Master Slave GPS common for unit 9 &10

NIL 2010 0

Condensate pot 1 set 2010 0.5

Erection hardware 1 set 2010 2

d SWAS System

indigenous

SWAS wet Panel 2010 0.7

SWAS dry panel 2010 0.5

SWAS imported - Analysers 2010

Conductivity Analyser 8 2010

Dissolve Oxygen analyser 2 2010

Hydrazine Analyser 1 2010

Silica Analyser 1 2010

pH Analyser 3 2010

e TSI 2010

Trbosupervisiory system

imported

1 set 2010 0.4

Turbine Supervisory system Indegeneous portion

1 set 2010 0.3

TSI spare 1 set 2014

Furniture for Pc & Printers 1 set 2010 0.5

Large vieo Screen (LVS) 1 no. 2010 0.3

HMI Control Desk 1 set 2010 0.2

Public Address System 1 set 2010 0.05

Temperature element RTD/TC

139 2010

f Oxygen analyser O2 1 set 2010

Flue gas analyser CO 2010

Smoke density Analyser 2010

Total (a+b+c+d+e+f) 27.15

Sub Total C&I for Unit 1-10

(P)

124.15

p Water Supply System

Cooling water Pump-

sets for unit 1 to 4

Condensor cooling pump-sets :

HSC, Q=4700 M3/hr, H=20

Mwc, 320 Kw

8 Nos. 1965 52

Cooling water Pump-

sets for unit 5 to 6

Condensor cooling pump-sets :

Vertical Pumps, Q=9000 M3/hr,

H=23 Mwc, 620 Kw

4 Nos. 1965 50

Cooling water Pump-

sets for unit 9 to 10

Page 48: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

48

Condensor cooling pump-sets :

HSC, Q=5520 M3/hr, H=30

Mwc, 620 Kw

6 Nos. 1985 75

Cooling water Pump-

sets for unit 7 to 8

Condensor cooling pump-sets :

HSC, 620 Kw (Unit 8 pumps are

dismantled with no motors present)

6 Nos. 1975 75

Flushing pumps, HSC, Q=720 m3/hr, H=89Mwc, Kw= 320

6 Nos. 1965 40

Condnser cooling water pipes

(Unit 1 to 10), MS, 1000 NB

300 M 1965 75

Cooling tower riser water pipes (unit 7 & 8), MS, 800 NB

240 M 1975 48

Cooling tower riser water pipes

(Unit 9 & 10), MS, 500

360 M 1985 38

Valves on suction side of cooling water pumpsets (Unit 1 to

48 Nos. 1965 150

10) : Gate valves : 1000 NB

Valves on delivery side of cooling

water pumpsets (Unit 1 to

24 Nos. 1965 60

10) NRV : 800 NB

Valves on cooling tower riser

for CT-9 & CT-10 : Gate

valves : 500 NB

36 Nos. 1965 36

Cooling tower for unit -7

Cooling towers : Fan motor

Rating= 67 kw each, Q= 18270

M3/HR (Total), no. of cells= 10

10 Nos. 1985 20

MS Pipe - DN 700 125 1985 18

Valve-700 2 1985 3.4

Cooling tower for unit -8

Cooling towers : Fan motor Kw= 67, Q= 18270 M3/HR

(Total), no. of cells= 10

10 Nos. 1985 1

MS Pipe - DN 700 125 1985 18

Valve-700 2 1985 3.4

Cooling tower for unit -9

Cooling towers : Fan motor

Rating= 55 Kw each cell, Q=

18270 M3/HR (Total), no. of

cells= 18 (15W+3S)

18 1985

20 Nos.(15W

+3S)

MS Pipe - DN 500 180 1985 19

Valve-500 18 1985 18

Cooling tower for unit -

10

Cooling towers : Fan motor

Rating= 55 Kw each cell, Q= 18270 M3/HR (Total), no. of

cells= 18 (15W+3S)

18 1985

20 Nos.(15W

+3S)

MS Pipe - DN 500 180 1985 19

Page 49: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

49

Valve-500 18 1985 18

Cooling tower for unit -1 (50 MW unit, 6 Cells) Civil structure in dismantled state and

items stored in Open Yard Cooling towers : Fan motor

Rating= 93 Kw for each cell,

Q= 7730 M3/HR (Total)

6 cells 1965 10

MS Pipe - DN 500 60 1965 6.5

Valve-500 6 1965 6

Cooling tower for unit -2 (50 MW unit, 6 Cells) Civil structure in dismantled state and

items stored in Open Yard Cooling towers : Fan motor

Rating= 93 Kw for each cell,

Q= 7730 M3/HR (Total)

6 cells 1965 10

MS Pipe - DN 500 60 1965 6.5

Valve-500 6 1965 6

Cooling tower for unit -3 (50 MW unit, 6 Cells) Civil structure in dismantled state and

items stored in Open Yard Cooling towers : Fan motor

Rating= 93 Kw for each cell, Q= 7730 M3/HR (Total)

6 cells 1965 10

MS Pipe - DN 500 60 1965 6.5

Valve-500 6 1965 6

Cooling tower for unit -4 (50 MW unit, 6 Cells) Civil structure in dismantled state

Cooling towers : Fan motor

Rating= 93 Kw for each cell,

Q= 7730 M3/HR (Total)

6 cells 1965 12

MS Pipe - DN 500 60 1965 6.5

Valve-500 6 1965 6

Cooling tower for unit -5 (100 MW unit, 10

Cells) Civil structure in dismantled state and

items stored in Open Yard

Cooling towers : Fan motor

Rating= 93 Kw for each cell,

Q= 12900 M3/HR (Total)

10 cells 1965 25

MS Pipe - DN 700 100 1965 14.5

Valve-700 2 1965 3.4

Cooling tower for unit -6 (100 MW unit, 10

Cells) Civil structure in dismantled state and

items stored in Open Yard

Cooling towers : Fan motor

Rating= 93 Kw for each cell,

Q= 12900 M3/HR (Total)

10 cells 1965 12

MS Pipe - DN 700 100 1965 14.5

Valve-700 2 1965 3.4

Fire Hydrant system

Fire water pump-sets : Q=273 M3/HR, H=88 Mwc, Kw= 110

2 Nos. 1985 5

Fire water Diesel engine driven pump-sets, Q=171 m3/hr, H=88

Mwc, 88 HP

2 No. 1985 5

Fire water pump-sets : Q=273 M3/HR, H=88 Mwc, Kw= 110

3 Nos. 2005 12

Fire water pipe lines 2005 90

Fire hydrants 80 Nos. 2005 10.5

Page 50: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

50

Fire water pipe lines 1985 15

Fire hydrants 30 Nos. 1985 4

Fire water pipe lines 1965 18

Fire hydrants 65 Nos. 1965 8.5

DM Plant (Russian Units)

DM Plant of capacity 70 m3/hr

(single stream) : Turnkey

1 No. 1965 175

DM Plant of capacity 50 m3/hr (single stream) : Turnkey

1 No. 1975 125

DM Plant of capacity 75 m3/hr

(single stream) : Turnkey

1 No. 1994 187.5

DM Plant (Indian Units)

DM Plant of capacity 80 m3/hr

(three stream: 2 W + 1S) :

Turnkey

3 Nos. 1981 600

PSF Feed pump-sets (Indian

units), Q=719, H=36, Motor

rating= 97 Kw

3 Nos. 1981 11.6

DM Water transfer pumps, 75

KW X 4 Nos.

4 Nos. 1981 30

DM Water transfer pumps, 50

KW X 2 Nos.

2 Nos. 1981 10

DM Water storage tank

DMWST : 300 M3, MOC : MSRL

2 Nos. 1981 37

DMWST : 500 M3, MOC : MSRL

2 Nos. 1981 60

DMWST : 150 M3, MOC :

MSRL

4 Nos. 1965 18

DMWST : 245 M3, MOC : MSRL

3 Nos. 1994 30

Anion outlet water storage

tank, capacity 500 m3 each,

2 Nos. 1981 120

DM Water transfer pipeline, DN

200, MSRL

300M 1965 21

DM Water transfer pipeline, DN

200, MSRL 300M 1981 21

Bearing cooling water Pump-

sets

Vertical turbine pump-sets, Q= 600 m3/hr, H=60mWC, 157 Kw

each

5 Nos. 1981 63

Vertical turbine drain water pump-sets, Q= 600 m3/hr,

H=60mWC, 157 Kw each

5 Nos. 1981 63

Gate valve DN 500 20 Nos. 1981 20

NRV, DN 500 10 Nos. 1981 10

Bearing cooling water pipes,

MS, 600 NB

1981 23

Subtotal (Q) 2840.7

Q Air Conditioning &

Ventilation Systems

Air Conditioning System

Page 51: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

51

1 Air Conditioning System for Unit

1 MCB Room - 20TR

Reciprocating type Centralized

AC

1 1980 1

2 Air Conditioning System for

Unit 1 & 2 Control Room -

15TR Water cooled Package

2 2006 1.2

3 Air Conditioning System for

Unit 3 & 4 Control Room -

15TR Water cooled Package

2 2011 1.2

4 Air Conditioning System for

Unit 5 & 6 Control Room -

15TR Water cooled Package

AC (out of 2 only 1 working)

2 2006

1.2

5 Air Conditioning System for

Unit 5 & 6 Control Room -

7.5TR Water cooled Package

2 2006 0.6

6 Air Conditioning System for Unit

7 & 8 Control Room - 20 - 22TR

Water cooled Package

3 1990 2.4

7 Air Conditioning System for

Unit 9 & 10 Control Room -

60TR Centrlized AC with AHU

2 2014 11

8 Air Conditioning System for Unit

7 & 8 ESP Control Room - 20TR Centrlized AC

2 1990 2

9 Air Conditioning System for Unit

9 & 10 ESP Control Room

- 7.5TR Air Cooled PAC

2 2014 0.6

Subtotal (R) 20.6

R Electrical Equipments-

Power generation &

Evacuation Systems

I. UNIT-1

1 Automatic voltage regulator of unit-1

1 Set 1966 0.4

2 The control, interlocking and

annunciation systems were

conventional contactor logic

based. The same were old and of

obsolete design. The protection

panels were having old

Russian make

electromechanical protective relays for generator, generator

transformer and UAT. R&M was

done.

1 Set 1966

20

3 Generator Circuit Beaker -

Rated voltage : 10.5 kV, Oil

filled

1 No. 1966

2 4 Generator CT, PT and LA are

old Russian make oil filled.

1 Lot 1966

5 Generator busduct - Rated voltage : 10.5 kV, Old Russian isolated phase busduct

1 Lot 1966

7.5

6 Rated voltage : 6.6 kV, old phase isolated Russian busduct

1 Lot 1966

7 LT busduct - Rated voltage : 400 V, old non phase segregated Russian busduct

1 Lot 1966

Page 52: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

52

8 Generator Transformer of unit-1

11T 40/60 MVA, ONAN/ONAF,

10.5/33/132 kV, 50 Hz, 202/ 700.6/ 175A (40

MVA)/3303.1/1051/262.7A

(60MVA) BHEL MAKE OLTC

(HV variation) - 9 Taps BHEL

1 No. 1966

75

9 HT Unit Auxiliary Transformer of unit-1, 21T - 7.5 MVA, 10.5 KV + (2)x2.5%/6.9 kV, 412/628

A, Y/Y-12 Oil cooled with

individual air blast, 5 MVA

without air blast

1 No. 1966

21

10 LT unit aux. transformer, 41T -

320 kVA, 6.6/0.420 kV, 28/440 A 1 No. 1966

0.5

11 6.6 kV unit switchgears of unit- 1

- Rated voltage : 6.6 kV, 1250 A, Type : MOCB

23 panels 1966

18.4

12 400/230 V unit switchgears of

unit-1 - 400/230 V SWGR (from 41T ) : 1 Set consisting of 11 panels

11 1966

16.8

Panles

13 400/230 V Distribution Centres of unit-1

17 1966

- 400/230 V DC of Boiler

Section-I : 1 Set consisting of

6panels

Panels

400/230V DC of turbine section-I : 1 Set consisting of 5 panels

400/230V DC for common facilities:1 Set consisting of 5

panels

Speed control open type panel of

PC feeders : 1 Set

14 Relay panel for LT unit aux.

Transformer - The protection

panel was located in UCR

having old

1 Lot 1966

Page 53: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

53

Russian make electromechanical protective

relays.

1.5

15 Local Starter panel / local push

button stations

1 Lot 1966

-For all HT as well as LT motors

16 HT Cables - Almost all the

cables are old Russian make

1 Lot 1966

paper insulated type suitable for

6.6 kV supply.

250

17 LT power and control cables 1 Lot 1966

- Almost all the cables are old Russian make rubber insulated

type suitable for 400V/230V

supply.

18 PC feeders - Complete electrics of

PC feeders including DC motors,

MCCs, speed variation equipment,

etc

1 lot 2003

19 ESP Electrics

a. ESP transformer- 1 - 1000kVA,

6.6/0.415kV, 87.47/1391.24A,

1 No. 1966

6

b. ESP switchgear –1 - 415 V,

Double front, consisting of all SFU units, each switchgear having

5 nos. front side multitier panels

and 4 nos. rear side multitier

panels

9 1966

5.4

panels

c. Electronic Controller

Thyristorised type with display

panel (There are two passes of

ESP in each unit, each pass having

three fields. No. of ECs are 3 Nos.

per pass &

6 Nos. 1966

8

6 nos. per unit.)

d. TR Set - There are 3 nos. of TR

sets per pass of ESP, 6 nos. per

unit.

6 Nos. 1966

20 Cooling Tower for unit-1 Civil structure in dismantled state and all items kept in

Open Storage Area

a. CT aux. Transformer 71T - 750

kVA, 6.6/0.420 kV, Y/y0-12,

65.6/1030 A

1 No. 1966

5

b. Cooling Tower switchgear-1 - 400/230 V SWGR (from 71T )

11 1966

Page 54: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

54

: 1 Set consisting of 11 panels panels

7.8

c. DC of gate valves of CT-1 -

400/230 V DCs : 1 Set consisting of 2 panels

2 1966

Panels

21 Uninterrupted power supply

system of adequate capacity and

redundancy separately for unit 1

(2x25 KVA) consisting of battery, charger & converter,

inverter, static transfer switch,

transformer, ACDB, cables,

wirings and other accessories

1 Set 2004

5

Sub total Unit 1 450.3

II UNIT-2

1 Automatic voltage regulator of

unit-2

1 Set 2004 0.4

2 The control, interlocking and

annunciation systems were was conventional contactor logic

based. The same were old and of

obsolete design. The protection

panels were g old Russian make

electromechanical protective

relays for generator, generator

transformer and UAT.

1 Set 2004

20

3 Generator Circuit Beaker 1 No. 1967

2

Rated voltage : 10.5 kV, MOCB

4 Generator CT, PT and LA

Generator CT, PT and LA are

old Russian make oil filled.

1 Lot 1967

5 Generator busduct Rated voltage

: 10.5 kV, Old Russian isolated

phase busduct

1 Lot 1967

7.5

6 6.6 kV busduct Rated voltage : 6.6 kV, old phase isolated

Russian busduct

1 Lot 1967

7 LT busduct, Rated voltage :

400 V, old non phase

segregated Russian busduct

1 Lot 1967

8 Generator, Transformer of unit- 2,

12T, 40/60 MVA, ONAN/ONAF,

10.5/33/132 kV,

50 Hz, YNyn0d11,

2202/700.6/175A (40

MVA)/3303.1/1051/262.7A

(60MVA),

1 No. 1967

75

BHEL MAKE OLTC (HV

variation) - 9 Taps BHEL

Page 55: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

55

9 HT Unit Auxiliary, Transformer

of unit-2, 22T, 7.5 MVA, 10.5 KV

+ (2)x2.5%/6.9 kV, 412/628

A, Y/Y-12. Oil cooled with individual air blast, 5 MVA

without air blast,

1 No. 1967

21

10 LT unit aux. transformer, 42T,

320 kVA, 6.6/0.420 kV,

28/440 A, SN, Y/y012, Z=5.3%

1 No. 1967 0.5

11 6.6 kV unit, switchgears of unit- 2, Rated voltage : 6.6 kV, 1250 A, Type : VCB

21 1967

16.8 Panels

12 400/230 V, switchgears of unit- 2,

400/230 V SWGR (from 42T

) : 1 Set consisting of 11 panels

11 2004

Panels

16.8 13 400/230 V, Distribution Centre of

unit-2, 400/230V DC of Boiler

Section-I : 1 Set of 6 panels,

400/230V DC of turbine section- I

: 1 Set of 5 panels, 400/230V DC

for common facilities:1 Set of 5 panels Speed control open type

panel of PC feeders : 1 Set

17 2004

Panels

14 Relay panels for LT transformers,

The protection panel was located in UCR having old, Russian make

electromechanical protective

relays.

1 Lot 2003

1.5 15 Local Starter panel / local push button station For all HT as well

as LT motors

1 Lot 1967

16 HT Cables, Almost all the cables

are old Russian make paper insulated type suitable for 6.6 kV

supply.

1 Lot 1967

250

17 LT power and control cables, Almost all the cables are old

Russian make rubber insulated

type suitable for 400V/230V

supply.

1 Lot 1967

18 PC feeders, Complete electrics of

PC feeders including DC motors,

MCCs, speed variation equipment,

etc

1 lot 2008

19 ESP Electrics

a. ESP transformer-2, 1000 kVA,

6.6/0.415 kV, 87.47/1391 A,

Dyn11, Z=5 %

1 No. 1967

6

Page 56: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

56

b. ESP switchgear –2, 415 V, Double

front, consisting of all SFU units,

Each switchgear having 5 nos.

front side multitier panels and 4 nos. rear side multitier panels

9 1967

5.4

panels

c. Electronic Controller,

Thyristorised type with display

panel (There are two passes of

ESP in each unit, each pass having

three fields. No. of ECs are 3 Nos.

per pass & 6 nos. per unit.

6 Nos. 1967

8 d. TR Set, There are 3 nos. of TR

sets per pass of ESP, 6 nos. per

unit.

6 Nos. 1967

20 Cooling Tower for unit-2,

Cooling Tower for unit-2 Civil structure in dismantled state and all items kept in

Open Storage Area

a. CT aux. Transformer 72T, 750

kVA, 6.6/0.420 kV, Y/y0-12,

65.6/1030 A,

1 No. 1967

5

b. Cooling Tower. switchgear-2,

400/230 V SWGR (from 72T ) : 1 Set consisting of 11 panels

11 1967

panels

7.8 c. DC of gate valves of CT-2, 400/230 V DCs : 1 Set

consisting of 2 panels

2 2004

Panels

Sub total Unit 2 443.7

1 DC SYSTEM (COMMON TO UNIT 1 & 2)

a. Battery 220 V, Lead Acid

Plante battery kept in a

separate battery room

(Common to unit – 1 & 2)

1 Set 2004

15

b. Battery Charger, There is a float

cum boost charger consisting of

two panels kept in MCB room (Common to unit

1 Set 1967

–1 & 2)

c. DCDB- The Russian make conventional DCDB system

1 set 1967

III. UNIT-3

1 Automatic voltage regulator of

unit-3

1 Set 1,968 0

2 Unit control, protection,

interlocking and annunciation

system, The control, interlocking

and annunciation systems are conventional contactor logic

based. The same are old and of

obsolete design. The protection

panels are having old Russian

make electromechanical protective

relays for generator, generator

transformer and UAT.

1 Lot 1968

20

3 Generator CT, PT and LA, Generator CT, PT and LA are old Russian make oil filled.

1 Lot 1968

Page 57: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

57

4 Generator- busduct, Rated

voltage : 10.5 kV, Old Russian

isolated phase busduct

1 Lot 1968 2

5 6.6 kV busduct Rated voltage : 6.6 kV, old phase isolated

Russian busduct

1 Lot 1968 7.5

6 LT busduct Rated voltage : 400 V,

old non phase segregated Russian

busduct

1 Lot 1968

7 Generator - Transformer of

unit-3 13T, 40/60 MVA,

ONAN/ONAF, 10.5/33/132 kV,

50 Hz, YNyn0d11 (MV

1 No. 1968

75 winding is unused),

2200/700/175A (40 MVA)

/ 3300/1050/262.5A (60 MVA),

8 HT Unit Auxiliary, Transformer of

unit-3, 23T, 7.5 MVA, 10.5 KV + (2)x2.5%/6.9 kV, 412/628

A, Y/Y-12, Oil cooled with

individual air blast, 5 MVA

without air blast

1 No. 1968 21

9 LT aux. unit - transformer, 43T,

320 kVA, 6.6/0.420 kV, 28/440

A, SN, Y/y012, Z=5.3%

1 No. 1968

0.5

10 6.6 kV unit - switchgears of unit-3, Rated voltage : 6.6 kV,

1250 A, Type : VCB,

21

Panels

2003

16.8

11 400/230 V - switchgears of unit-

3, 400/230 V SWGR (from 42T)

: 1 Set consisting of 11 panels

11

Panels

1968

16.8 12 400/230 V - Distribution Centre of

unit-3, 400/230V DC of Boiler

Section-I : 1 Set consisting of 6

panels, 400/230V DC of turbine

section-I : 1 Set consisting of 5

panels, 400/230V DC for common facilities:1Set

consisting of 5 panels Speed

control open type panel of PC

feeders : 1 Set

17

Panels

1968

13 Relay panels for LT aux.

transformers - The protection

panel was located in UCR having

old, Russian make

electromechanical protective

relays.

1 Lot 1968

1.5 14 Local Starter panel / local push

button station, For all HT as well

as LT motors

1 Lot 1968

15 HT Cables, Almost all the cables

are old Russian make paper

insulated type suitable for 6.6 kV

supply.

1 Lot 1968 250

Page 58: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

58

6 LT power and control cables -

Almost all the cables are old

Russian make rubber, insulated type suitable for 400V/230V

supply.

1 Lot 1968

17 PC feeders - Complete electrics of

PC feeders including DC motors,

MCCs, speed variation equipment,

etc

1 lot 1968

18 ESP ELECTRICS

a. ESP transformer- 3, 1000kVA,

6.6/0.415kV, 87.47/1391.24A,

ONAN, Dyn11, Z=5%, No. of

taps : 5 (OCTC)

1 No. 2004

6

b. ESP switchgear – 3, 415 V,

Double front, consisting of all

SFU units, Each switchgear

having 5 nos. front side multitier

panels and 4 nos. rear side multitier panels

9

panels

2004

5.4

c. Electronic Controller -

Thyristorised type ECs with display panel (There are two

passes of ESP in each unit, each

pass having three fields. No. of

ECs are 3 Nos. per pass &

6 Nos. 2004

8

6 nos. per unit)

d. TR Set - There are 3 nos. of TR sets per pass of ESP, 6 nos. per unit .

6 Nos. 2004

19 Cooling Tower for unit-3 -

Cooling Tower for unit-3 Civil structure and all other items in dismantled state and

kept in Open Storage Area

a. CT aux. - Transformer 73T, 750

kVA, 6.6/0.420 kV, Y/y0-

12, 65.6/1030 A,

1 No. 1968

5

b. Cooling Tower - switchgear-3, 400/230 V SWGR (from 71T )

11 1968

7.8

: 1 Set consisting of 11 panels panels

c. DC of gate valves of CT-3,

400/230 V DCs : 1 Set

consisting of 2 panels

2 1968

Panels

Sub total Unit 3 443.7

IV. UNIT-4

1 AVR - Automatic voltage regulator of unit-3

1 Set 2004 0.4

Page 59: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

59

Unit control, protection,

interlocking and annunciation system, The control,

interlocking and annunciation

systems are conventional contactor logic based. The same

are old and of obsolete design.

The protection panels are having old Russian make

electromechanical protective

relays for generator, generator transformer and UAT.

1 Lot 2004

20

3 Generator CT, PT and LA, Generator CT, PT and LA

are old Russian make oil

filled.

1 Lot 1969

2 4 Generator busduct Rated

voltage : 10.5 kV, Old

Russian isolated phase busduct

1 Lot 1969

5 6.6 kV busduct - Rated

voltage : 6.6 kV, old phase

isolated Russian busduct

1 Lot 1969

6 LT busduct - Rated voltage

: 400 V, old non phase

segregated Russian busduct

1 Lot 2004 7.5

7 Generator - Transformer of unit-4, 14T, 40/60 MVA, ONAN/ONAF, 10.5/132 kV, 50 Hz, YNd11, 2202/175.2A

(40 MVA) / 3300/262.7A (60

MVA),

1 No. 1969

75

8 HT Unit Auxiliary - Transformer of unit-4, 24T,

7.5 MVA, 10.5 KV +

(2)x2.5%/6.9 kV, 412/628 A, Y/Y-12,

1 No. 1969

21

Oil cooled with individual air blast, 5 MVA without air blast

9 LT aux. unit - transformer, 44T, 320 kVA, 6.6/0.420 kV,

28/440 A, SN, Y/y012, Z=5.3%

1 No. 1969

0.5

10 6.6 kV unit - switchgears of

unit-4, Rated voltage : 6.6

kV, 1250 A, Type : MOCB

21 1969

16.8

Panels

11 400/230 V - switchgears of

unit-4, 400/230 V SWGR (from 42T ) : 1 Set consisting of

11 panels

11 2004

Panels

Page 60: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

60

12 400/230 V - Distribution Centre

of unit-4, 400/230V DC of Boiler Section-I : 1 Set of 6

panels, 400/230V DC of turbine

section-I : 1 Set of 5 panels, 400/230V DC for common

facilities:1 Set of 5 panels,

Speed control open type panel of PC feeders : 1 Set

17 2004 16.8

Panels

13 Relay panels for LT unit transformer, The protection

panel was located in UCR

having old, Russian make electromechanical protective

relays.

1 Lot 2008

14 Local Starter - panel / local push button station, For all

HT as well as LT motors

1 Lot 1969 1.5

15 HT Cables - Almost all the cables are old Russian make

paper insulated type suitable

for 6.6 kV supply.

1 Lot 1969 250

16 LT power and control cables - Almost all the cables are old

Russian make rubber

insulated type suitable for

400V/230V supply.

1 Lot 1969

17 PC feeders - Complete

electrics of PC feeders including DC motors,

MCCs, speed variation

equipment, etc

1 lot 2007

18 ESP Electrics

a. ESP transformer- 4 1 No. 1994 6

b. ESP switchgear –4, 415 V,

Double front, consisting of all SFU units, Each

switchgear having 5 nos.

front side multitier panels and 4 nos. rear side multitier

panels

9 1994

5.4

Panels

c. Electronic - Controller,

Thyristorised type ECs with display panel (There are two

passes of ESP in each unit,

each pass having three fields. No. of ECs are 3 Nos. per

pass &

6 Nos. 1994

6 nos. per unit)

Page 61: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

61

d. TR Set - There are 3 nos. of

TR sets per pass of ESP, 6 nos. per unit.

6 Nos. 1994

8

19 Cooling Tower for unit – 4, Cooling Tower for unit – 4

Civil structure and all other items in dismantled state and

kept in Open Storage Area

a. CT aux. - Transform.-74T, 750 kVA, 6.6/0.420 kV, Y/y0-

12, 65.6/1030 A,

1 No. 1969

5

b. Cooling Tower switchgear-4 - 400/230 V SWGR (from 71T ) : 1 Set consisting of 11 panels

11 1969

7.8

panels

c. 2 1969

DC of gate valves of CT-4 - 400/230 V DCs : 1 Set consisting of 2 panels

Panels

Sub total Unit 4 443.7

1 DC SYSTEM (COMMON

TO UNIT 3 & 4)

a. Battery - 220 V, Lead Acid Plante battery kept in a

separate battery room

(Common to unit – 3 & 4) (800Ah)

1 Set 2003

15

b. Battery Charger - There is old

Russian make charger kept in

UCR room. (Common to unit –3 & 4)

1 Set 1,969

c. DCDB - The Russian make

conventional DCDB kept in

the UCR.

1 set 1,969

2 STATION

TRANSFORMERS

INCLUDING

AUTO

TRANSFORMERS

a. HT Station - transformer 9T,

10 MVA, 33/6.6 kV,OLTC

(No. of taps : 9), Total

1 No. 1963 32

b. HT Station transformer 10T, 12.5 MVA, 33/6.6 kV,

218.7/1093.5 A, 50 Hz, ONAN, OLTC (No. of taps :

9),

1 No. 1994

26

c. Auto transformer - AT-1, HV : 75/110/150 MVA,

189/276/377 A, LV :

75/110/150 MVA, 312/457/623 A TV : 25/36.7/50 MVA,

438/642/875 A, 230/139/33

kV,

1 No. 1983

Page 62: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

62

ON/OB/OFB, Z=9.61%,

Yy0d11, Impulse voltage : 900/550/170/170kV (HV/LV/TV/N) Power

frequency withstand voltage :

395/230/70/70kV (HV/LV/TV/N), OLTC (No. of

taps : 13)

160

d. Auto transformer - AT-2, HV : 75/110/150 MVA,

189/276/377 A, LV :

75/110/150 MVA,

312/457/623 A TV : 25/36.7/50 MVA,

438/642/875 A, 230/139/33

kV,

1 No. 1981 160

ON/OB/OFB, Z=9.61%, Yy0d11, Impulse voltage : 900/550/170/170kV

(HV/LV/TV/N) Power frequency withstand voltage :

395/230/70/70kV

(HV/LV/TV/N), OLTC (No. of taps : 13)

47.5

e. LT Station transformer 51T, 52T & 56T, 560 kVA,

6.6/0.420 kV, 49/770 A, Z=7.7 %, ONAN

3 Nos. 1969

24 f. LT Standby Transformer

40T, 50T& 70T, 560 kVA,

6.6/0.420 kV, 49/770 A, Z=7.7 %, ONAN

3 Nos. 1969

3 STATION SWITCHGEARS

a. 6.6 kV station - switchgears

section-I, 6.6 V, 1250 A, MOCB board (fed from 9T)

Insulation level : 12 kV/28

kV/75 kVp,

22 1969

34.4

Panels

b. 6.6 kV station, switchgears section-II, 6.6 V, 1250 A,

MOCB board (fed from 10T),

Insulation level : 12 kV/28 kV/75 kVp,

21 1969

Panels

c. 400/230 V Station switchgear-I, 400/230 V

SWGR (from 51T ) : 1 Set

consisting of 15 panels

15 1969

Panels

d. 400/230 V- Station

switchgear-I, 400/230 V

15 1969

Page 63: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

63

SWGR (from 52T ) : 1 Set

consisting of 15 panels

Panels

25.2

e. 400/230 V Station, switchgear-III, 400/230 V

SWGR (from 56T ) : 1 Set

consisting of 12 panels

12 1969

Panels

4 MG SET

a. MG set - MG set for unit-1 : 1

No., MG Set for unit-2 : 1 No.

MG Set for unit-3 : 1 No., MG Set for unit-4 : 1 No. MG Set

for Trickle charger : 3 Nos., MG

Set for Quick charger : 2 Nos., MG Set for H2 plant : 2 Nos.,

Each of the above

11 1969

Nos.

MG set is having motor of 55 kW

15 b. MG Set - MG Set of reserve

excitation, Motor rating :

400 kW, 6.6 kV, 42 A, 985 RPM

1 Set 1969

c. MCB ROOM - MCB room has control, mimic, annunciation & indication for

the 33/132/220 kV outgoing

lines, all the generator bays, auto transformer bays, station

bays and 6.6kV/400 V power

distribution systems and is comprising of the 25 nos. front

side panels. On rear side of the

above front panels, there are 22 nos. protection/control panels

for the various LT auxiliary

transformers, HT transformers,

DC distribution systems, etc.

47 1969

20

Panels

5 RELAY ROOM - Relay room

is located near the 132 kV

switchyard and are having protective relays for all the 33

kV and 132 kV outgoing line

feeders.

1 Lot 1969

Subtotal Aux 1 559.1

6 CHP (RUSSIAN SIDE

COAL HANDLING

PLANT)

All equipment, machineries and auxiliaries, except

material handling equipment, of CHP area have been

dismantled and kept in the Open Storage Area

a. CHP - Control/relay panel

Control, monitoring, mimic, annunciation, metering and

protection panel/desk

1 Lot 1967

2

c. LT CHP aux. transformer 61T, 62T & 65T, 320 kVA,

6.6/0.420 kV, 28/440 A, Z=5.3 %, ONAN

3 No. 1967

3

d. 400/230 V CHP - 10 1967

Page 64: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

64

switchgears section-I, 400/230

V SWGR (fed from 61T ) : 1

Set consisting of 10 panels

Panels

25

e. 400/230 V CHP - switchgear

section-II, 400/230 V SWGR

(fed from 62T ) : 1 Set consisting of 8 panels

8 1967

Panels

g 400/230 V DC of wagon tippler – 1, 400/230 V SWGR

(fed from 65T ) : 1 Set

consisting of 12 panels Plus it‟s extension board consisting

of 11 panels

23 1967

Panels

h. HT Cables - Almost all the cables are old Russian make

paper insulated type suitable for 6.6 kV supply.

1 Lot 1967

100 i. LT power and control cables Almost all the cables are old

Russian make rubber insulated

type suitable for 400V/230V supply.

1 Lot 1967

j. Local Starter panel / local push button station For all

HT as well as LT motors

1 Lot 1967

k. Miscl. Electircs - Mounted

electrics like limit switches,

pull cord, belt sway switches,

etc including electrics of other equipment like padal feeder,

swing feeder,

mobile teppler, pusher car, and other miscellaneous

equipment

1 Lot 1967

2

7 ILLUMINATION

a. LT lighting - Transformer 53T

& 54T, 560 kVA, 6.6/0.420 kV,

49/770 A, Z=7.6 %, ON

2 Nos. 1967

4

b. 400/230 V lighting

switchgear - 400/230 V

SWGR (fed from 53T & 54T) : 1 Set consisting of 8 panels

8 1967

6.4

Panels

c. Illumination -system -

Illumination system of unit-1, 2, 3 & 4, 132 kV and 33 kV

switchyards and all the balance

of plants like, H2 plant, coal handling plant, ash handling

plant, fuel oil pump house,

water system premises, DM plant, compressor house, area

and street lighting, etc.

1 Lot 1967

Page 65: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

65

d. Aviation light - Chimney

aviation warning lights to be provided.

1 lot 1967 8

8 COOLING TOWER

(STAND BY SUPPLY TO

COOLING TOWERS

Civil structure and all other items in dismantled state and

kept in Open Storage Area OF UNIT-1,2,3 & 4)

a. LT common Transformer for

CTs, 60T, 750 kVA, 6.6/0.420

kV, 65.6/1030 A,

1 No. 1967

5

b. 400/230 V std by CT swgr.

400/230 V SWGR (fed from

60T) : 1 Set consisting of 2 panels

2 1967

1.2

Panels

9 DM PLANT

a. LT aux. transformer at CWTP, 63T, 630 Kva,

6.6/0.420 kV, 55.01/865 A, ON, Yy0

1 No. 1967

5

b. LT MCC at New DM Plant (70M3/hr) 415 V MCC (fed

from 63T ) : 1 Set consisting of

5 panels each of multitier SFUs

5 1967

4

Panels

c. DM Plant (old), Control

Panel, (2x35M3/hr +

1x36M3/hr), DM Plant control panel consisting of

mimic, annunciators and

control equipment.

1 Lot 1967

4 d. LT MCC at DM Plant(2x35M3/hr

+1x36M3/hr), 415 V MCC : 1 Set consisting of 5 panels each of multitier SFUs

5 1967

Panels

e. HT Cables - Almost all the

cables are old Russian make paper insulated type suitable for

6.6 kV supply.

1 Lot 1967

22

f. LT power and control cables Almost all the cables are old

Russian make rubber insulated

type suitable for 400V/230V supply.

1 Lot 1967

g. Local Starter panel / local push button station For all

the LT motors

1 Lot 1967

10 ASH HANDLING SYSTEM

1 ASH WATER SYSTEM - ASH WATER SYSTEM

Page 66: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

66

. AWPH Control panel -

AWPH control panel consisting of mimic,

annunciators and control

equipment.

1 Lot 1967

15 b. 6.6 kV switchgears at AWPH- 6.6 V, 1250 A, Air Circuit

Beaker (Type DSE25), board

consisting of 17 panels

17 1967

Panels

c. Ash handling LT Transformer 1 & 2, 250 kVA, 6.6/0.433 kV,

21.87/393.35 A, Dy-11, Z=6.45

%, ONAN

2 Nos. 1967

2

d. 415 V MCC at AWPH - 415 V MCC consisting of ACBs

9 1967

as I/C and B/C feeders and SFUs as O/G feeders.

Panels 5.4

e. HT Cables - Almost all the cables are old Russian make

paper insulated type suitable for

6.6 kV supply.

1 Lot 1967

56

f. LT power and control cables

- Almost all the cables are

old Russian make rubber

insulated type suitable for 400V/230V supply.

1 Lot 1967

g Local Starter - panel / local

push button station, For all

HT as well as LT motors

1 Lot 1967

2 ASH DISPOSAL SYSTEM -

ASH DISPOSAL SYSTEM

a. Control panel - ADPH

control panel consisting of

mimic, annunciators and control equipment.

1 Set 1967

0.5

b. HT Cables - Almost all the

cables are old Russian make

paper insulated type suitable for 6.6 kV supply.

1 Lot 1967

20

e. LT power and control cables - Almost all the cables are old Russian make rubber

insulated type suitable for 400V/230V supply.

1 Lot 1967

f. Local Starter - panel / local

push button station, For all HT as well as LT motors

1 Lot 1967

Page 67: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

67

11 FOPH (FUEL OIL

HANDLING SYSTEM)

a. LT power and control cables - Almost all the cables are old Russian make rubber insulated type suitable for

400V/230V supply.

Lot 1967

25 b. Local Starter - panel / local

push button station, For all

the LT motors

Lot 1967

12 H2 PLANT (HYDROGEN

PLANT)

a. LT MCC AT H2 PLANT -

400 V MCC : 1 Set

consisting of 5 panels

5 1967

3 Panels

b. LT power and control cables

- Almost all the cables are old Russian make rubber

insulated type suitable for

400V/230V supply.

1 Lot 1967

c. Earthing and lightning protection - Earthing and

lightning protection of unit 1,

2, 3 & 4 and all the BOPs

1 lot 1967

SUBTOTAL- Auxiliaries 2

368.5

V. UNIT-5

1 AVR -Automatic voltage

regulator of unit-5

1 Set 1971 0.5

2 Unit control, protection,

interlocking and annunciation system -The control,

interlocking and

annunciation systems were conventional contactor logic

based. The same were old and

of obsolete design. The protection panels were having

old Russian make

electromechanical protective relays for generator, generator

transformer and UAT.

1 Lot (30 1971

20

panel aprx)

3 Generator CT, PT and LA - Generator CT, PT and LA

are old Russian make oil filled.

1 Lot 1971

2 4 Generator busduct -Rated

voltage : 10.5 kV, Old

Russian isolated phase

busduct (copper)

1 Lot 1971

5 6.6 kV busduct -Rated voltage : 6.6 kV, old phase

isolated Russian busduct

1 Lot 1971

Page 68: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

68

6 LT busduct -Rated voltage :

400 V, old non phase segregated Russian busduct

1 Lot 1971 7.5

7 Generator Transformer of unit-

5 15T-62.5/87.5/125 MVA, ON/OB/OFB, 10.5/220 kV, 50

Hz, Yd11, 6562/301 A ( at 125

MVA), Z = 12.26

1 No. 1971

150

8 HT Unit Auxiliary Transformer of unit-5 25T &

26T -7.5 MVA, 10.5 KV +

(2)x2.5%/6.9 kV, 412/628 A, Y/Y-12,

2 Nos. 1971

Oil cooled with individual air

blast, 5 MVA without air blast, Weight of core and coils : 9.0

T, Weight of fitting and

radiators : 6.0 T, Oil capacity : 5.8 T, Total weight of

transformer : 20.8 T

20.8

9 LT auxi. Unit transformer,

45T & 46T -320 kVA, 6.6/0.420 kV, 28/440 A, SN,

Y/y012, Z=5.3 %

2 Nos. 1971

6

10 6.6 kV unit switchgears of unit-5 -There are two MOCB boards

for two boilers of unit- 5 (boiler

No. 5 & 6) each board consisting of 21 panels Rated

voltage : 6.6 kV, 1250 A, Type :

MOCB

42 1971

33.6

panels

11 400/230 V switchgears of

unit-5 -400/230 V DC of

boiler-5 : 12 panels (fed from

45T) 400/230 V DC of boiler-

6 : 10 Panels (fed from 46T)

22 1971

39

Panels

12 400/230 V Distribution

Centres of unit-5 -400/230 V DC of Boiler House - 5 : 12

panels 400/230 V DC of boiler

- 6 : 11 Panels 400/230 V

43 1971

Page 69: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

69

GVDC of boiler : 10 Panels

GVDC for turbine

: 8 Panels Speed control

open type panel of PC feeders : 2 Sets

Panels

13 PC feeders -Complete electrics of PC feeders

including DC motors,

MCCs, speed variation equipment, etc

1 Lot 1971

14 Relay panel for LT unit transformer -The protection

panel was located in UCR having old Russian make

electromechanical protective

relays.

1 Lot 1971

4 15 Local Starter panel / local

push button station -For all

HT as well as LT motors

1 Lot 1971

16 HT Cables -Almost all the cables are old Russian make

paper insulated type suitable

for 6.6 kV supply.

1 Lot 1971

340 17 LT power and control cables -Almost all the cables are old

Russian make rubber

insulated type suitable for 400V/230V supply.

1 Lot 1971

18 ESP Electrics -ESP Electrics

a. ESP transformer 5-(i) & (ii) -

1000kVA, 6.6/0.415kV,

87.47/1391.23A, ONAN, Dy11 Z=6.39%

2 Nos. 1994

6

b. ESP switchgear 5 – (i) & (ii) -415 V, Double front,

consisting of all SFU units : 2 boards Each board having 5

nos. front side multitier

panels and 4 nos. rear side multitier panels

18 1994

11

panels

c. Electronic Controller -

Thyristorised type with display panel (There are two passes of

ESP in each boiler, each pass

having three fields. No. of ECs are 3 Nos. per pass. 6 nos. per

boiler). For the two boilers, No.

of EC : 12

12 Nos. 1994

12 d. TR Set -There are 3 nos. of TR

sets per pass of ESP, 6 nos. per boiler and 12 Nos. per unit.

12 Nos. 1994

19 Cooling Tower for unit-5 - Cooling Tower for unit-5

Civil structure and all other items in dismantled state and

kept in Open Storage Area

Page 70: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

70

a. CT aux. Transformer 75T & 76T -750 kVA, 6.6/0.420 kV, Y/y0-12, 65.6/1030 A

2 Nos. 1971

5

b. Cooling Tower switchgear 5

- (i) & (ii) -400/230 V SWGR (from 75T ) : 1 Set consisting of 11 panels

400/230 V SWGR (from

76T ) : 1 Set consisting of 11 panels

22 panels 1971

13.2

20 2 Nos. 1971

MG set -Each of the MG set is having motor of 55 kW

5 21 Earthing& lightning system - Earthing mat and it‟s

interconnections are available.

Lightning protection is there.

1 Lot 1971

SUBTOTAL- Unit 5 675.6

VI. UNIT-6

1 AVR -Automatic voltage

regulator of unit-6

1 Set 1972 0.5

2 Unit control, protection,

interlocking and annunciation system -The control,

interlocking and

annunciation systems were conventional contactor logic

based. The same were old and

of obsolete design. The

protection panels were having

old Russian make

electromechanical protective relays for generator, generator

transformer and UAT.

1 Lot (30 1972

20

panels aprx)

3 Generator CT, PT and LA - Generator CT, PT and LA are

old Russian make oil filled.

1 Lot 1972

2 4 Generator busduct -Rated

voltage : 10.5 kV, Old

Russian isolated phase busduct

1 Lot 1972

5 6.6 kV busduct -Rated

voltage : 6.6 kV, old phase

isolated Russian busduct

1 Lot 1972

7.5 6 LT busduct -Rated voltage :

400 V, old non phase

segregated Russian busduct

1 Lot 1972

Page 71: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

71

7 Generator Transformer of

unit-6 16T -125 MVA, 10.5/220 kV, 50 Hz, OCTC

(HV variation) - 9 Taps

1 No. 1972

150

8 HT Unit Auxiliary

Transformer of unit-5 27T & 28T -7.5 MVA, 10.5 KV +

(2)x2.5%/6.9 kV, 412/628 A, Y/Y-12,

2 Nos. 1972

Oil cooled with individual air

blast, 5 MVA without air blast, Weight of core and coils : 9.0

T, Weight of fitting and

radiators : 6.0 T, Oil capacity : 5.8 T, Total weight of

transformer : 20.8 T

20.8

9 LT auxi. Unit transformer,

47T & 48T -320 kVA, 6.6/0.420 kV, 28/440 A,

ONAN, Y/y012, Z=5.3 %

2 Nos. 1972

6

10 6.6 kV unit switchgears of unit-

6 -There are two MOCB boards

for two boilers of unit- 5 (boiler

No. 7 & 8) each board consisting of 21 panels Rated

voltage : 6.6 kV, 1250 A, Type :

MOCB

42 panels 1972

33.6

11 400/230 V switchgears of unit-

6 -400/230 V DC of boiler-7 :

12 panels (fed from 45T) 400/230 V DC of boiler- 8 : 10

Panels (fed from 46T)

22 1972

39

Panels

12 400/230 V Distribution

Centres of unit-6 -400/230 V

DC of Boiler House - 5 : 12 panels 400/230 V DC of boiler

- 6 : 11 Panels 400/230 V

GVDC of boiler : 10 Panels GVDC for turbine

: 8 Panels Speed control

open type panel of PC feeders : 2 Sets

43 1972

Panels

13 PC feeders -Complete

electrics of PC feeders including DC motors,

MCCs, speed variation

equipment, etc

1 Lot 1972

Page 72: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

72

14 Relay panel for LT unit

transformer -The protection panel was located in UCR

having old Russian make

electromechanical protective relays.

1 Lot 1972

15 Local Starter panel / local

push button station -For all HT as well as LT motors

1 Lot 1972 4

16 HT Cables -Almost all the

cables are old Russian make paper insulated type suitable

for 6.6 kV supply.

1 Lot 1972

340 17 LT power and control cables -

Almost all the cables are old

Russian make rubber

insulated type suitable for 400V/230V supply.

1 Lot 1972

18 ESP Electrics

a. ESP transformer 6-(i) & (ii) - 1000kVA, 6.6/0.415kV,

87.47/1391.23A, ONAN,

Dy11 Z=6.39%

2 Nos. 1994

6

b. ESP switchgear 6 – (i) & (ii) - 415 V, Double front, consisting

of all SFU units : 2 boards Each

board having 5 nos. front side multitier panels and 4 nos. rear

side multitier panels

18 1994

11

panels

c. Electronic Controller -

Thyristorised type with

display panel (There are two passes of ESP in each boiler,

each pass having three fields.

No. of ECs are 3 Nos. per pass. 6 nos. per boiler). For

the two boilers, No. of EC :

12

12 Nos. 1994

12

d. TR Set -There are 3 nos. of

TR sets per pass of ESP, 6

nos. per boiler and 12 Nos. per unit.

12 Nos. 1994

19 Cooling Tower for unit-6 Civil structure and all other items in dismantled state and

kept in Open Storage Area

a. CT aux. Transformer 77T & 78T -750 kVA, 6.6/0.420 kV,

Y/y0-12, 65.6/1030 A

2 Nos. 1972

5

b. Cooling Tower switchgear 6 - (i) & (ii) -400/230 V SWGR (from 75T ) : 1 Set

consisting of 11 panels

400/230 V SWGR (from 76T ) : 1 Set consisting of

11 panels

22 1972

13.2

panels

Page 73: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

73

20 MG set -Each of the MG set is

having motor of 55 kW

2 Nos. 1972

21 Earthing& lightning system -

Earthing mat and it‟s interconnections are available.

Lightning protection is there.

1 Lot 1972 5

a. DC SYSTEM (COMMON

TO UNIT 5 & 6) TO BE

KEPT INDIVIDUAL FOR

UNIT- 5 0R 6

1 Battery -220 V, Lead Acid Plante battery kept in a separate

battery room (Common to unit –

5 & 6)

1 Set (900AH) 2014

18

2 Battery Charger -There is a Russian make conventional

charger installed in UCR.

1 Set 1972

3 DCDB -The Russian make

conventional DCDB is kept

in the UCR.

1 set 1972

b. ILLUMINATION

1 LT lighting Transformer 55T -560 kVA, 6.6/0.420 kV, 49/770 A, Z=7.6 %, ON

1 No. 1972

4

2 400/230 V lighting switchgear -400/230 V SWGR (fed from 55T) : 1 Set consisting of 5

panels

5 1972

34

Panels

3 Illumination system -

Illumination system of unit - 5

& 6, area and street lighting, etc.

1 Lot 1972

SUBTOTAL- Unit 6 731.6

VII. UNIT-7

1 Unit control, protection, interlocking and annunciation

system -All Control Desks/

Panels are old conventional having contactor based logics

and annunciators of obsolete

design. Unit protection panels are consisting of old electro-

mechanical type protective

relays for generator, Generator Transformer and UAT.

1 Lot 1977

30 2 AVR -Transistorised controlled

having two independent

channels – Auto

/ Manual.

1 Set 1977

Page 74: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

74

3 Generator CT, PT and LA -

Generator CT, PT and LA are housed in three panel located

at ground level.

1 Set 1977

7.5

4 1 Lot 1977

Generator busduct -Rated voltage : 11 kV, isolated phase busduct

2.5

5 Generator Transformer of unit-7 17T -125/87.5/62.5

MVA, OFAF/ ONAF/

ONAN, 11/242 kV, 50 Hz, Yd11,

1 Set 1977

160

Z- 12.5 %, Tap Changer- OFF Load type with 5 tap

positions.

6 HT Unit Auxiliary

Transformer of unit-7, 29T (7X03) -15 MVA, ON, 11 /

6.9 KV, 50 Hz, Ddo, Z- 9.15 %, Tap

1 Set 1977

30 changer – On Load type

7 LT auxiliary unit transformer, 7X04 & 7X05 -750 kVA,

6.6/0.415 kV, 65.6/1042 A,

SN, DY1, Z = 5.16 %

2 Nos. 1977

4

8 6.6 kV unit switchgears of unit-7, 7A01 -Rated voltage

30 Panels 1977

30

: 6.6 kV, 1250 A, Type :

MOCB

9 415 V switchgears of unt-7

7B01 & 7B02 -2 nos. 415 V

Switchgear consisting of ACBs , CT/ PT, meters ,

protective relays etc having

11 panels in each Switchgear.

22 1977

17.6

Panels

10 415 V , MCCs of unit-7 -

Turbine Aux. MCC (7B11) : 6 Panels Draft Group MCC

(7B12) : 11 Panels Burner

Group MCC (7B13) : 11 Panels Turbine M.O Valve

MCC (7B14) : 10 Panels

Turbine Aux. MCC (7B21) : 5 Panels Mill Group MCC

(7B22) : 9 Panels Dust Coal

MCC (7B23) : 6 Panels Turbine M.O Valve MCC

(7B24) : 10 Panels Boiler

M.O Valve MCC (7B25) : 9 Panels Soot Blower MCC

(7B25A) : 13 Panels 2nd

LOP MCC : 6 Panels Ventilation MCC (B14) : 5

Panels

12 Sets 1977

67.2

Page 75: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

75

11 Local Starter panel / local

push button station -For all HT as well as LT motors

1 Lot 1977

4

12 HT Cables -Almost all the cables are paper insulated

1 Lot 1977

type suitable for 6.6 kV supply.

180

13 LT power and control cables -Almost all the cables are PVC insulated type suitable for 415V supply.

1 Lot 1977

120

14 PC feeders -Complete electrics of PC feeders

including MCCs

1 Lot 1977

15 ESP ELECTRICS

a. ESP transformer-7 -

1000kVA, 6.6/0.415kV,

87.47/1391.24A, ONAN, Dyn11, Z=5%

1 No. 1977

6

b. ESP MCC – 7 -415 V MCCs for Unit – 7

consisting of ACB, SFU,

contactors, O/L etc.

11 1977

7.7 panels

c. Electronic Controller -

Thyristorised type with display

panel (There are two passes of ESP in unit each pass having

four fields. no. of ECs are 4

Nos. per pass and 8 nos. per unit )

8 Nos. 1977

4

d. Wrapping Panels -

Microprocessor based

control panels having 2 panels for the unit

2 nos. 1977

0.8

e. TR Set -There are 4 nos. of

TR sets per pass of ESP, 8

nos. per unit . Rating of set : 78 kVp / 1000 mA DC.

8 Nos. 1977

5

16 COOLING TOWER

a. 415 V Switchgear (7B03) -

415 V Switchgear consisting of ACBs, SFUs, Contactors,

meters, relays etc

9 panels 1977

7.2

b. LT Aux. Transformer (7X06) - 1000 kVA, 6.6 / 0.415 kV,

87.5/1390 A, SN, DY11, Z- 5.6%

1 No. 1977

6

SUBTOTAL- Unit 7 689.5

VIII. UNIT-8

Page 76: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

76

1 Unit control, protection,

interlocking and annunciation system -All Control Desks/

Panels are old conventional

having contactor based logics and annunciators of obsolete

design. Unit protection panels

are consisting of old electro- mechanical type protective

relays for generator, Generator

Transformer and UAT.

1 Lot 1979

2 AVR -Transistorised

controlled having two independent channels –

Auto / Manual.

1 Set 1979 30

3 Generator CT, PT and LA -

Generator CT, PT and LA are

housed in three panel located at ground level.

1 Set 1979

7.5

4 Generator busduct -Rated

voltage : 11 kV, isolated

phase busduct

1 Lot 1979

2.5

5 Generator Transformer of unit-

8 18T -137.5/96/68.5 MVA, OFAF/ ONAF/ ONAN,

11/242 kV, 50 Hz, YNd11,

1 Set 1979

180

Z- 12.58 %, Tap Changer- OFF Load type with 5 tap

positions.

Weight of core & winding : 108020 Kg Weight of oil : 47920 Kg Total

weight:224200 Kg

6 HT Unit Auxiliary

Transformer of unit-8, 30T

(8X03) -15 MVA, ON, 11 / 6.9 KV, 50 Hz, Ddo, Z- 9.15 %, Tap

1 Set 1979

30

changer – On Load type

Weight of core & winding :

16.75 Tons Weight of cooling

plant with oil : 13.45 Tons Total weight including oil :

42.30 Tons Year of

manufacturing : 1975

7 LT auxiliary unit transformer,

8X04 & 8X05 -750 kVA, 6.6/0.415 kV, 65.6/1042 A, SN,

DY1, Z=5.16 %

2 Nos. 1979

4

8 6.6 kV unit switchgears of

unit-8, 8A01 -Rated voltage

30 Panels 1979

Page 77: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

77

: 6.6 kV, 1250 A, Type :

MOCB

30

9 415 V switchgears of unt-8

8B01 & 8B02 -2 nos. 415 V

Switchgear consisting of ACBs , CT/ PT, meters ,

protective relays etc having

11 panels in each Switchgear.

22 1979

17.6

Panels

10 415 V , MCCs of unit-8 -

Turbine Aux. MCC (8B11) : 6 Panels Draft Group MCC

(8B12) : 11 Panels Burner

Group MCC (8B13) : 11

Panels Turbine M.O Valve

MCC (8B14) : 10 Panels

Turbine Aux. MCC (8B21) : 5 Panels Mill Group MCC

(8B22) : 9 Panels Dust Coal

MCC (8B23) : 6 Panels Turbine M.O Valve MCC

(8B24) : 10 Panels Boiler M.O Valve MCC (8B25) : 9

Panels Soot Blower MCC

(8B25A) : 13 Panels 2nd LOP MCC : 6 Panels

Ventilation MCC (B19) : 5

Panels

12 Sets 1979

67.2

11 Local Starter panel / local

push button station -For all

HT as well as LT motors

Lot 1979

4

12 HT Cables -Almost all the

cables are paper insulated

type suitable for 6.6 kV supply.

Lot 1979

120

13 LT power and control cables -Almost all the cables are

PVC insulated type suitable for 415V supply.

Lot 1979

240

14 PC feeders -Complete electrics of PC feeders

including MCCs

1 Lot 1979

15 ESP ELECTRICS

a. ESP transformer-8 -

1000kVA, 6.6/0.415kV,

87.47/1391.24A, ONAN, Dyn11, Z=5%

1 No. 1979

6

b. ESP MCC – 8 -415 V MCCs

for Unit – 8 consisting of

ACB, SFU, contactors, O/L etc.

11 1979

8.8 panels

c. Electronic Controller -

Thyristorised type with

display panel (There are two passes of ESP in unit each

pass having four fields. no. of

ECs are 4 Nos. per pass and 8 nos. per unit

)

8 Nos. 1979

3.2

Page 78: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

78

d. Wrapping Panels -

Microprocessor based control panels having 2

panels for the unit

2 nos. 1979

0.8

e. TR Set -There are 4 nos. of

TR sets per pass of ESP, 8 nos. per unit . Rating of set

: 78 kVp / 1000 mA DC.

8 Nos. 1979

4

a. 415 V Switchgear (8B03) - 415 V Switchgear consisting

of ACBs, SFUs,

Contactors, meters, relays etc

9 panels 1979

7.2

b. LT Aux. Transformer (8X06) -1000 kVA, 6.6 / 0.415 kV, 87.5/1390 A, SN, DY11, Z-

5.6%

1 No. 1979

4

A. STATION

TRANSFORMER &

STATION SWGR

(COMMON TO UNIT-7 &

8)

1 Station transformer (X01) -20 MVA, 230/ 6.9 kV,

50.2/1674A,ON, Yd11, 50 Hz

with ON Load Tap Changer.

1 No. 1977

90

2 Station LT Aux.

Transformer (X02, X03) -

1000 kVA, 6.6/0.415 kV, 87.5 /1390A, 50 Hz, Dy11, Z= 6.5%

2 Nos. 1977

6

3 Series Reactor

Transformer- 1&2 -Reactive

2 Nos. 1977

3 6.6 kV, 1200A, 3Ph, 50 Hz,

ON Insulation level – 60

kVp

4 6.6 kV switchgear (A01) -

Rated voltage : 6.6 kV, 1250 A, Type : MOCB

24 Panels 1977

24

5 Station LT Aux. Switchgear (B01) -415 V Switchgear

consisting of ACBs , CT/

PT, meters , protective relays etc.

15 1977

12

Panels

6 Standby 11 1977

8.8

Station LT Aux. Switchgear

(B02)

Panels

-415 V Switchgear consisting

of ACBs , CT/ PT, meters ,

protective relays etc.

7 415 V common MCCs -

Station Aux. MCC (B16) – 5

Panels. Ventilation MCC (B13) - 5 Panels

2 Sets 1977

8 Local Starter panel / local

push button station -For all

HT as well as LT motors

Lot 1977

Page 79: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

79

B. DC SYSTEM (COMMON

TO UNIT – 7 & 8)

1 Battery -220 V, 800 AH, Lead

Acid battery kept in a separate battery room (Common to unit –

7 & 8)

1 Set 2003

2 Battery Charger -There is a float cum boost charger kept

in separate room adjacent to

Battery room. (Common to unit – 7 & 8)

1 Set 1977

20 3 DCDB -DCDB with SFUs,

meters etc. and associated cables and wirings

1 Set 1977

C. INDOOR ADPH (Common

for Unit-7 & 8)

1 6.6 kV unit switchgears -

Rated voltage : 6.6 kV,

1250 A, Type : MOCB

13 Panels 1977

13

2 415 V switchgears -415 V

Switchgear cum MCC

consisting of ACBs , CT/ PT, meters , relays, SFUs,

Contactors etc.

9 1977

7.2

Panels

3 LT Aux. Transformer -750

kVA, 6.6 / 0.415 kV, 65.6/1042 A, SN, DY1, Z- 5.16%

2 No. 1977

3

4 Local Starter panel / local

push button station -For all HT as well as LT motors

Lot 1977

2

5 HT Cables -Almost all the

cables are paper insulated

type suitable for 6.6 kV supply.

Lot 1977

30

6 LT power and control cables -Almost all the

cables are PVC insulated

type suitable for 415V supply.

Lot 1977

200

D. COOLING TOWER

ELECTRICS (Common for

Unit-7

& 8 )

1 Standby 415 V switchgears (

B08 ) -415 V Switchgear

consisting of ACBs , CT/ PT, meters , relays etc.

3 1977

2.4

Panels

2 Standby LT Aux. Transformer ( X10 ) -1000

kVA, 6.6 / 0.415 kV,

87.5/1390 A, SN, DY11, Z- 5.6%

1 No. 1977

4

Page 80: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

80

3 Local Starter panel / local

push button station -For all HT as well as LT motors

Lot 1977 2

4 LT power and control cables -Almost all the cables are PVC insulated type suitable for

415V supply.

Lot 1977 2

E. FUEL OIL / LDO PUMP

HOUSE (Common for Unit 7

& 8 )

1 415 V MCC -Fuel oil system MCC – B16A

6 1977

6 panels

2 Local Starter panel / local push button station -For all

HT as well as LT motors

Lot 1977

2

3 LT power and control

cables -Almost all the

cables are PVC insulated type suitable for 415V supply.

Lot 1977

2

F. MISC. PUMP HOUSE (

Common for Unit 7 & 8 )

1 LT Aux. Transformer ( X07 ) -

750 kVA, 6.6 / 0.415 kV,

65.6/1042 A, SN, DY1, Z- 5.16%

1 No. 1977

3

2 415 V switchgears ( B05 ) -

415 V Ash water Board consisting of ACBs , CT/ PT,

meters , relays etc.

9 1977

7.2

Panels

3 415 V MCC -415 V Ash

water MCC – B51

5 1977

3.5 panels

4 Local Starter panel / local

push button station -For all HT as well as LT motors

Lot 1977

2

5 LT power and control cables -Almost all the

cables are PVC insulated

type suitable for 415V supply.

Lot 1977

2

G. ASH DISPOSAL PUMP

HOUSE (ADPH)-Common

for units 7 to 10

1 LT Aux. Transformer ( X08 ) -

750 kVA, 6.6 / 0.415 kV,

65.6/1042 A, SN, DY1, Z-

5.16%

1 No. 1977

3

2 415 V switchgears ( B06 ) -

415 V Ash Slurry Board consisting of ACBs , CT/ PT,

meters , relays etc.

10 1977

8

Panels

3 415 V MCC -415 V Ash Slurry MCC – B61

5 1977

3 panels

4 Local Starter panel / local

push button station -For all HT as well as LT motors

Lot 1977

2

Page 81: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

81

5 LT power and control cables

-Almost all the cables are PVC insulated type suitable

for 415V supply.

Lot 1977

2

H. WANSON PLANT/DM

PLANT (Common for Unit 7

to 10)

1 415 V MCC -415 V DM Plant MCC ( both sided)

9 panels 1977 5.4

2 Local Starter panel / local

push button station -For all

HT as well as LT motors

Lot 1977

2

3 LT power and control

cables -Almost all the

cables are PVC insulated type suitable for 415V supply.

Lot 1977

2

I. RAW WATER PUMP

HOUSE ( Common for

Unit 7 to 10 )

1 Local Starter panel / local push button station -For all

HT as well as LT motors

1 Lot 1977

2

2 LT power and control cables -Almost all the cables are PVC insulated type suitable

for 415V supply.

1 Lot 1977

3

J. COAL HANDLING SYSTEM

ELECTRICS (Common

for Unit 7 to 10 )

1 Control system -Control,

monitoring, mimic,

annunciation, metering and

protection panel/desk

1 Lot 1977 2

2 LT Aux. Transformer (X05 &

X06) -1000 kVA, 6.6 / 0.415

kV, 87.5/1390 A, SN, DY11, Z- 5.6%

2 No. 1977

4

3 415 V Switchgear -Coal

Handling Board – B04 having ACBs, relays,

meters, ct/pt etc. – 13 panels

Stacker Reclaimer Board – B07 – 8 panels

2 Sets 1977

8

4 415 V MCC -Coal handling

MCC (B44) : 7 Panels Coal

handling MCC (B46) : 7 Panels

6 Sets 1977

26.4

Coal handling MCC (B45) : 8

Panels Coal bunker MCC (B42)

: 7 Panels Coal bunker MCC (B41) : 7 Panels Coal bunker

MCC (B43) : 8 Panels

Page 82: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

82

6 LT Aux. Transformer for

Stacker Reclaimer ( X09 ) - 200 kVA, 6.6 / 0.415 kV,

17.5/266.8 A, ON, DY11, Z-

1 No. 1977

1 4.34%

7 Misc. Electrics -Mounted devices like limit switches,

pull cords, belt sway

switches ( if available)

1 Lot 1977

including electrics of magnetic

separaters, peddle feeder,

swing feeder, mobile trippler etc.

2

8 Local Starter panel / local push button station -For all

HT as well as LT motors

1 Lot 1977

2

9 HT Cables -Almost all the

cables are paper insulated

type suitable for 6.6 kV supply.

1 Lot 1977

15

10 LT power and control

cables -Almost all the cables are PVC insulated

type suitable for 415V supply.

1 Lot 1977

12

K. ILLUMINATION SYSTEM

for Unit 7, 8 and

switchyards and

all the Indian side BOPs

1 Transformer for Lighting (X04

) -500 kVA, 6.6 / 0.415 kV, SN, DY1, Z- 4.90%

1 No. 1977

2

2 Main Lighting Board -414 V

Lighting switchgear with

ACBs, SFUs etc.

8 1977

5.6 Panels

3 Plant illumination system -

Illumination Level of unit-7 & 8, 220 kV switchyard and all

the balance of plants like, coal

handling plant, ash handling plant, fuel oil pump house,

water system premises, DM

plant, compressor house, area and street lighting, etc.

1 Lot 1977

5

P Earthing and lightning

protection of unit 7 & 8 and all the BOPs

1 lot 1977

10

SUBTOTAL- Unit 8 1363

IX. UNIT-9

Page 83: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

83

Unit control, protection,

interlocking and annunciation system -All Control Desks/

Panels are old conventional

having contactor based logics and annunciators of obsolete

design. Unit protection panels

are consisting of old electro- mechanical type protective

relays for generator,

Generator Transformer and UAT.

1 Lot 1984

30

2 AVR -Transistorised controlled

having two independent channels – Auto

/ Manual.

1 Set 1984

3 Generator CT, PT and LA -

Generator CT, PT and LA are housed in three panel located

at ground level.

1 Set 1984 7.5

4 Generator busduct -Rated

voltage : 11 kV, isolated

phase busduct

1 Lot 1984

2.5

5 Generator Transformer of

unit- 19T -125/87.5/62.5

MVA, OFAF/ ONAF/ ONAN, 11/242 kV, 50 Hz, Yd11,

1 Set 1984

140

Z- 12.5 %, Tap Changer-

OFF Load type with 5 tap positions.

6 HT Unit Auxiliary Transformer of unit-9, -15 MVA, ON, 11 /

6.9 KV, 50 Hz, Ddo, Z- 9.15

%, Tap changer – On Load type

1 Set 1984

30

7 LT auxiliary unit transformer, -750 kVA, 6.6/0.415 kV, 65.6/1042 A, SN, DY1, Z =

5.16 %

2 Nos. 1984

4

8 6.6 kV unit switchgears of unit-9, -Rated voltage : 6.6 kV, 1250

A, Ttpe: VCB

30 Panels 1984

30

9 415 V switchgears of unt-9 -2

nos. 415 V Switchgear

consisting of ACBs , CT/ PT, meters , protective relays etc

having 11 panels in each

Switchgear.

22 1984

17.6

Panels

Page 84: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

84

10 415 V , MCCs of unit-9 -

Turbine Aux. MCC (7B11) : 6 Panels Draft Group MCC

(7B12) : 11 Panels Burner

Group MCC (7B13) : 11 Panels Turbine M.O Valve

MCC (7B14) : 10 Panels

Turbine Aux. MCC (7B21) : 5 Panels Mill Group MCC

(7B22) : 9 Panels Dust Coal

MCC (7B23) : 6 Panels Turbine M.O Valve MCC

(7B24) : 10 Panels Boiler

M.O Valve MCC (7B25) : 9 Panels Soot Blower MCC

(7B25A) : 13 Panels 2nd

LOP MCC : 6 Panels Ventilation MCC (B14) : 5

Panels

12 Sets 1984

57.6

11 Local Starter panel / local

push button station -For all HT as well as LT motors

1 Lot 1984 4

12 HT Cables -Almost all the

cables are paper insulated type suitable for 6.6 kV

supply.

1 Lot 1984 180

13 LT power and control cables -Almost all the cables are PVC insulated type suitable

for 415V supply.

1 Lot 1984

120 14 PC feeders -Complete electrics of PC feeders

including MCCs

1 Lot 1984

15 ESP ELECTRICS

a. ESP transformer-9 -

1000kVA, 6.6/0.415kV,

87.47/1391.24A, ONAN,

Dyn11, Z=5%

1 No. 1984 6

b. ESP MCC – 9 -415 V MCCs for Unit – 7

consisting of ACB, SFU, contactors, O/L etc.

11 1984

7.7 panels

c. Electronic Controller - Thyristorised type with

display panel (There are two

passes of ESP in unit each pass having four fields. no. of

ECs are 4 Nos. per pass and 8

nos. per unit )

8 Nos. 1984

3.2

d. Wrapping Panels - Microprocessor based

control panels having 2

panels for the unit

2 nos. 1984

1.2

e. TR Set -There are 4 nos. of TR sets per pass of ESP, 8 nos. per

unit . Rating of set : 78 kVp /

1000 mA DC.

8 Nos. 1984

5

16 COOLING TOWER

Page 85: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

85

a. 415 V Switchgear -

consisting of ACBs, SFUs,

Contactors, meters, relays etc

9 panels 1984

7.2

b. LT Aux. Transformer -1000 kVA, 6.6 / 0.415 kV,

87.5/1390 A, SN, DY11, Z- 5.6%

1 No. 1984

6

SUBTOTAL- Unit 9 659.5

X. UNIT-10

1 Unit control, protection,

interlocking and annunciation

system -All Control Desks/ Panels are old conventional

having contactor based logics

and annunciators of obsolete design. Unit protection panels

are consisting of old electro-

mechanical type protective relays for generator, Generator

Transformer and UAT.

1 Lot 1986

30

2 AVR -Transistorised

controlled having two independent channels –

Auto / Manual.

1 Set 1986

7.5 3 Generator CT, PT and LA -

Generator CT, PT and LA are housed in three panel located

at ground level.

1 Set 1986

4 Generator busduct -Rated voltage : 11 kV, isolated

phase busduct

1 Lot 1986

2.5

5 Generator Transformer of unit-

10 20T -137.5/96/68.5 MVA,

OFAF/ ONAF/ ONAN, 11/242 kV, 50 Hz,

1 Set 1986

140

YNd11, Z- 12.58 %, Tap

Changer- OFF Load type with

5 tap positions. Weight of core & winding : 108020 Kg

Weight of oil : 47920 Kg Total

weight : 24200 Kg

6 HT Unit Auxiliary

Transformer of unit-10-15

MVA, ON, 11 / 6.9 KV, 50 Hz, Ddo, Z- 9.15 %, Tap

changer – On Load type

Weight of core & winding : 16.75 Tons Weight of cooling

plant with oil : 13.45 Tons

Total weight including oil : 42.30 Tons Year of

manufacturing : 1975

1 Set 1986

30

7 LT auxiliary unit transformer, -750 kVA, 6.6/0.415 kV,

65.6/1042 A, SN, DY1,

Z=5.16 %

2 Nos. 1986 4.5

Page 86: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

86

6.6 kV unit switchgears of unit-

10 -Rated voltage : 6.6 kV, 1250 A, Type : VCB

30 Panels 1986 30

9 415 V switchgears of unt-10 - 2

nos. 415 V Switchgear consisting of ACBs , CT/ PT,

meters , protective relays etc

having 11 panels in each Switchgear.

22 1986 17.6

Panels

10 415 V , MCCs of unit-10 -

Turbine Aux. MCC (8B11) : 6 Panels Draft Group MCC

(8B12) : 11 Panels Burner

Group MCC (8B13) : 11 Panels Turbine M.O Valve

MCC (8B14) : 10 Panels

Turbine Aux. MCC (8B21) : 5

Panels Mill Group MCC (8B22)

: 9 Panels Dust Coal MCC

(8B23) : 6 Panels Turbine M.O Valve MCC

(8B24) : 10 Panels Boiler

M.O Valve MCC (8B25) : 9 Panels Soot Blower MCC

(8B25A) : 13 Panels 2nd

LOP MCC : 6 Panels Ventilation MCC (B19) : 5

Panels

12 Sets 1986 8.4

11 Local Starter panel / local push button station -For all

HT as well as LT motors

Lot 1986

40

12 HT Cables -Almost all the

cables are paper insulated

type suitable for 6.6 kV

supply.

Lot 1986

180

13 LT power and control

cables -Almost all the

cables are PVC insulated type suitable for 415V supply.

Lot 1986

120 14 PC feeders -Complete

electrics of PC feeders including MCCs

1 Lot 1986

15 ESP ELECTRICS

a. ESP transformer-10 -

1000kVA, 6.6/0.415kV, 87.47/1391.24A, ONAN,

Dyn11, Z=5%

1 No. 1986

6

b. ESP MCC – 10 -415 V MCCs for Unit – 8

consisting of ACB, SFU, contactors, O/L etc.

11 1986

6.6 panels

c. Electronic Controller -

Thyristorised type with display

panel (There are two passes of ESP in unit each pass having

four fields. no. of ECs are 4

Nos. per pass and 8 nos. per unit )

8 Nos. 1986 4

Page 87: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

87

. Wrapping Panels -

Microprocessor based control panels having 2 panels for the

unit

2 nos. 1986

0.8

e. TR Set -There are 4 nos. of TR

sets per pass of ESP, 8 nos. per unit . Rating of set : 78 kVp /

1000 mA DC.

8 Nos. 1986

4

16 COOLING TOWER

a. 415 V Switchgear -415 V

Switchgear consisting of ACBs,

SFUs, Contactors, meters, relays etc

9 panels 1986

6.3

b. LT Aux. Transformer -1000 kVA, 6.6 / 0.415 kV,

87.5/1390 A, SN, DY11, Z- 5.6%

1 No. 1986

6

A. STATION TRANSFORMER

& STATION SWGR

(COMMON TO UNIT-9 &

10)

1 Station transformer (X01) - 20

MVA, 230/ 6.9 kV,

50.2/1674A,ON, Yd11, 50 Hz with ON Load Tap

Changer.

1 No. 1984

42

2 Station LT Aux.

Transformer (X02, X03) -

1000 kVA, 6.6/0.415 kV, 87.5 /1390A, 50 Hz, Dy11, Z= 6.5%

2 Nos. 1984

6

3 Series Reactor Transformer-

1&2 -Reactive

2 Nos. 1984

0.6 6.6 kV, 1200A, 3Ph, 50 Hz,

ON Insulation level – 60 kVp

4 6.6 kV switchgear (A01) - Rated voltage : 6.6 kV, 1250 A,

Type : MOCB

24 Panels 1984

24

5 Station LT Aux. Switchgear

(B01) -415 V Switchgear

consisting of ACBs , CT/ PT, meters , protective relays etc.

15 1984

12

Panels

6 Standby Station LT Aux.

Switchgear (B02) -415 V

Switchgear consisting of ACBs , CT/ PT, meters ,

protective relays etc.

11 1984

2.4

Panels

7 415 V common MCCs - Station Aux. MCC (B16) – 5

Panels. Ventilation MCC

(B13) - 5 Panels

2 Sets 1984

6

8 Local Starter panel / local push button station -For all

HT as well as LT motors

Lot 1984

5

B. DC SYSTEM (COMMON

TO UNIT – 9 & 10)

Page 88: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

88

1 Battery -220 V, 800 AH, Lead

Acid battery kept in a separate battery room (Common to unit –

7 & 8)

1 Set 2003

2 Battery Charger -There is a

float cum boost charger kept in separate room adjacent to

Battery room. (Common to unit

– 7 & 8)

1 Set 1984 20

3 DCDB -DCDB with SFUs, meters etc. and associated cables and wirings

1 Set 1984

C. INDURE ADPH (Common

for Unit-9 & 10)

1 6.6 kV unit switchgears -

Rated voltage : 6.6 kV, 1250 A, Type : MOCB

13 Panels 1984

13

2 415 V switchgears -415 V Switchgear cum MCC

consisting of ACBs , CT/ PT,

meters , relays, SFUs, Contactors etc.

9 1984

7.2

Panels

3 LT Aux. Transformer -750

kVA, 6.6 / 0.415 kV,

65.6/1042 A, SN, DY1, Z- 5.16%

2 No. 1984

3

4 Local Starter panel / local

push button station -For all

HT as well as LT motors

Lot 1984 1.5

5 HT Cables -Almost all the

cables are paper insulated type suitable for 6.6 kV

supply.

Lot 1984

30

6 LT power and control cables -Almost all the cables are PVC insulated type suitable

for 415V supply.

Lot 1984

120

D. COOLING TOWER

ELECTRICS (Common for

Unit-9 & 10 )

1 Standby 415 V switchgears ( B08 ) -415 V Switchgear

consisting of ACBs , CT/ PT,

meters , relays etc.

3 1984

2.1

Panels

2 Standby LT Aux.

Transformer ( X10 ) -1000

kVA, 6.6 / 0.415 kV, 87.5/1390 A, SN, DY11, Z- 5.6%

1 No. 1984

4

3 Local Starter panel / local

push button station -For all

HT as well as LT motors

Lot 1984

0.3

Page 89: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

89

4 LT power and control cables

-Almost all the cables are PVC insulated type suitable

for 415V supply.

Lot 1984

2

E. FUEL OIL / LDO PUMP

HOUSE (Common for Unit 9

& 10 )

1 6 1984

415 V MCC -Fuel oil system MCC – B16A

panels 4.2

2 Local Starter panel / local

push button station -For all HT as well as LT motors

Lot 1984

0.6

3 LT power and control cables -Almost all the cables are PVC insulated type suitable for

415V supply.

Lot 1984

4

F. MISC. PUMP HOUSE (

Common for Unit 9 & 10 )

1 LT Aux. Transformer ( X07 ) -750 kVA, 6.6 / 0.415 kV, 65.6/1042 A, SN, DY1, Z-

5.16%

1 No. 1984

3

2 415 V switchgears ( B05 ) -

415 V Ash water Board

consisting of ACBs , CT/ PT, meters , relays etc.

9 1984

7.2

Panels

3 415 V MCC -415 V Ash

water MCC – B51

5 1984

3.5 panels

4 Local Starter panel / local

push button station -For all

HT as well as LT motors

Lot 1984

0.6

5 LT power and control cables -Almost all the

cables are PVC insulated

type suitable for 415V supply.

Lot 1984

4

G. ILLUMINATION SYSTEM

for Unit 9 & 10

1 Transformer for Lighting (X04

) -500 kVA, 6.6 / 0.415 kV,

SN, DY1, Z- 4.90%

1 No. 1984

2

2 Main Lighting Board -414 V

Lighting switchgear with

ACBs, SFUs etc.

8 1984

3 Panels

3 Plant illumination system - Illumination Level of unit-7 &

8, 220 kV switchyard and all

the balance of plants like, coal handling plant, ash handling

plant, fuel oil pump house,

water system premises, DM plant, compressor house, area

and street lighting, etc.

1 Lot 1984

10

H. Earthling and lightning

protection of unit 7 & 8 and all

the BOPs

1 lot 1984

25

Page 90: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

90

SUBTOTAL-Unit 10 1012.4

SUBTOTAL(S)- Electrics 7840.9

S Workshop Equipment

1 Lathe Machine, HMT/H-22/25

50 1 1975

Lathe Machine, HMT/H-22/25

49 1 1975

3 Lathe Machine, HMT/LB-

20G/21 88 1 1975

4 Lathe Machine, HMT/LB-

20G/22 86 1 1975

5 Lathe Machine, HMT/LB-

20G/21 87 1 1975

6 Lathe Machine, HMT/LB-

20G/22 65 1 1975

7 Lathe Machine, Coimbatoor

120 / 10 95 1 1975

8 Milling Machine, HMT/M-

2/U/25 99 1 1975

9 Milling Machine, HMT/M-

2/U/26 88 1 1975

10 Drill Machine, HMT/RM/63/1917

1 1975

11 Drill Machine, HMT/1/B/567 1 1975

12 Grinding Machine, 10C3BC0C2

1 1975

13 Shapper Machine 1 1975

14 Shapper Machine 1 1975

15 Rolling Machine 1 1975

16 Rolling Machine 1 1975

17 Cutter Machine 1 1975

18 Drill Machine 1 1975

19 Drill Machine 1 1975

20 Lathe Machine, HMT/L-

45/14148 1 1975

21 Lathe Machine, MHT/B-

2/13217 1 1975

22 Milling Machine, HMT/FN- 3U/1310

1 1975

23 Drill Machine, HMT/RM-

65/35346 1 1975

24 Universal Grinding M/C,

GTC/28T/01408 1 1975

25 Grinding Machine, VC/-/471 1 1975

26 Lathe Machine, HMT/L-

50/14201 1 1975

27 Lathe Machine, HMT/NH-

26/4402 1 1975

28 Lathe Machine, HMT/NH-

26/4313 1 1975

29 Boring Machine, HMT/AZ-9/HB

423 1 1975

30 Grinding Machine, VC/-/471 1 1975

SUBTOTAL- Workshop (approximate weight in MT) 10.00

Page 91: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

91

DETAILS OF STEEL STRUCTURE

Sl.No.

Description

Type of construction

Type of finish/floor ing Unit Plinth area (m2) Quantities

of Steel

( MT )

A. Structures inside Isolating

Boundary

1 MAIN POWER HOUSE BLDG.

(Russian unit)

RCC RCC 282x44 500

2 MAIN POWER HOUSE BLDG.

(INDIAN

unit)

STEEL RCC slab supported on

Steel beams.

270x44 14000

3 Conveyor galleries STEEL 500

4 Junction Houses & crushing bldg STEEL 400

5 STORAGE SHEDS STEEL 1500

6 IPPL STEEL 600

7 Filtration Plant STEEL 40

8 Monorails in pump houses STEEL 20

9 Miscellaneous auxiliary units. STEEL 200

B. Structures outside Isolating Boundary (Dismantled and kept at Storage Area)

10 Conveyor galleries STEEL 2500

11 Junction Houses & crushing bldg STEEL 400

12 Wagon Tippler STEEL 91

13 Miscellaneous auxiliary units. STEEL 150

TOTAL= 20901

DETAILS OF CIVIL (RCC) BUILDING Sl No.

Unit

Concrete Brickwork

Dismantling Qty Dismantling Qty

cum Sqm

1 RUSSIAN SIDE TG Buildings 11290 5190

2 Indian SIDE TG Buildings 12000

3 Control Room 1310 1280

4 Chimney 9650

5 Boiler side ESP Bldg 45 205

6 BCW Bldg. 310 1255

7 WTP Bldg. 285 1190

8 Compressor Bldg. 150 500

9 Cooling Tower 6580

10 24 Nos. RCC column near Boiler no.6 50

11 RCC Duct Russian side 375

12 Small Building 6 nos 25 220

Total Qty. 42070 9840

Page 92: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

92

9. Special Terms & Conditions (STC) of Sale of Decommissioned Plant

These special Terms and Conditions (hereinafter called “STC” or “Special Terms and

Conditions”) are to be read in conjunction with other terms & conditions mentioned

elsewhere in the Auction Documents and are supplementary to them. However, in case of

any contradiction, these Special Terms and Conditions shall prevail over any other

conditions/provisions mentioned elsewhere in the Auction Documents.

THE DECOMMISIONED PLANT , LIST OF ITEMS FOR DISPOSAL, TC and STC

DISPLAYED UNDER "VIEW FORTHCOMING AUCTIONS" ON MSTC'S E-AUCTION

WEBSITE ARE TENTATIVE AND SUBJECT TO CHANGE AT THE SOLE DISCRETION

OF MSTC OR PATRATU VIDYUT UTPADAN NIGAM LTD BEFORE THE START OF E-

AUCTION. BIDDERS SHOULD, THEREFORE, DOWNLOAD THE BID DOCUMENT OF

DECOMMISIONED PLANT, LIST OF ITEMS FOR DISPOSAL, TC and STC DISPLAYED

ONLY UNDER "VIEW LIVE AUCTIONS" FOR THEIR RECORD PURPOSE, IF

REQUIRED, AND BID ACCORDINGLY. FOR BUYERS GUIDELINES VISIT

“www.mstcecommerce.com” and “www.mstcindia.co.in”.

9.1 Sale of the Decommissioned Plant shall be made to the highest auction bidder “Subject to

Approval “of its quoted price by the owner namely Patratu Vidyut Utpadan Nigam Ltd

(hereinafter referred to as “PVUNL” or “Owner” or “Principal” or “Seller”) or any person(s)

duly authorized by it in this regard (hereinafter called as “Owner‟s Authorized

Representatives”) and on the terms and conditions and special terms & conditions mentioned

in Auction catalogue on “As Is Where Is and No Complaint Basis”. Further PVUNL

reserves its right to cancel or terminate the auction and / or sale of items/materials of auction

at any point of time till all items /materials are lifted. Under such circumstances, the bidder

(s) / buyer (s) shall have no right to claim any compensation or damage or loss of profit etc.

in any manner whatsoever.

9.2 M/s MSTC Limited is the Selling Agent of PVUNL and hereinafter referred to as MSTC.

The “Buyer” or “Contractor” or “Successful Bidder” mentioned anywhere in the Auction

Catalogue refers to the participating bidder who has offered the highest price in the Auction

and whose bid has been accepted by the Owner.

De-commissioned Plant is sold on Ex PVUNL Patratu Site basis. Dismantling, Handling,

Loading, Transportation, Insurance, Storage, Safety of workmen, labor, operators &

equipment, materials, items and structures of self as well as others in close vicinity, meeting

statutory requirements, compliance with the Rules, Acts and Laws of the Land, etc. shall rest

with the Buyer (s) and neither MSTC nor PVUNL will be responsible for the same in any

manner, whatsoever. The participating bidders shall comply with all Rules, Acts and Laws of

the Central Government of India or the concerned State Government or the local bodies or

their authorized Departments for purchase, transportation and storage of various

Page 93: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

93

items/materials for which they intend to participate in the Auction. Further they shall obtain the

requisite Permits, Licenses, Permissions, Registration, etc. from the concerned Departments or

bodies. An indicative but not the exhaustive list of Rules, Acts and Laws is given below:

a) Central Motor Vehicles Rules, 1989 and its subsequent amendments for transportation;

b) Manufacture, Storage and Import of Hazardous Chemical Rules, 1989 and its subsequent

amendments for storage and import of Hazardous chemicals;

c) Various Laws, Rules and Acts of Petroleum and Explosives Safety Organization, Dept. of

Industrial Policy & Promotion, Ministry of Commerce & Industry, Govt. of India;

d) Labour Laws of Central and concerned State Governments;

e) Employee‟s Compensation Act, 1923, etc.

The participating bidders are advised in their own interest to appraise themselves with various

Rules, Acts and Laws of the Land. PVUNL and/or MSTC shall not be responsible in any

manner, whatsoever for any liability, commercial or otherwise, due to non-compliance or

non-adherence to such Rules, Acts and Laws.

Further, PVUNL reserves the right to check any permit or license or certificate or permission

at any stage till the Decommissioned Plant is completely disposed off, site is cleared as

specified and EMD is released. Any non- compliance observed at any stage will render the

bid invalid and lead to forfeiture of Pre Bid EMD and/or EMD and/or Security Deposit

and/or any payment made to PVUNL/MSTC till the date of observance of such non-

compliance in addition to any other action that MSTC and PVUNL and Law enforcement

agencies may take against the Buyer. Bidders may also note that checking of the aforesaid

documents by MSTC and/or PVUNL will neither be construed by the Buyer as certification

by the Owner or MSTC of compliance of Rules, Acts and Laws of the Land by him nor relieve

the Buyer from compliance of Rules, Acts and Laws of the Land. Under all circumstances,

Buyer shall solely be responsible for meeting statutory requirements and compliance with the

Rules, Acts and Laws of the Land.

9.3 The entire offer shall be valid for a period of 120 calendar days from the date of closing

of e-auction which may be extended for any further period of time as may be mutually

agreed upon by PVUNL and Buyer.

9.4 Bidders have to quote for the entire lot together against this e-auction. Bids for part of lot

will not be accepted by the portal.

9.5 It will be at the sole discretion of PVUNL to accept or cancel the sale without assigning

any reason.

Page 94: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

94

9.6 The completion period shall be 30 months from the date of issue of the Sale Release

Order by PVUNL.

9.7 THE AUCTION CATALOGUE ON THE E- AUCTION FLOOR AS ON THE DATE

OF AUCTIONING SHALL BE TREATED AS FINAL AND BINDING.

The material as per the list declared on the MSTC‟s website shall be disposed off by

way of e-auction through ww.mstcecommerce.com.

The Buyer must clearly understand that MSTC/PVUNL, PATRATU do not guarantee

the correctness or accuracy of any description printed, readout or verbally declared. The

prospective bidders may inspect the Decommisioned Plant offered for e- auction sale

within the Inspection Period during working hours, at the site where the Plant is located.

The bidders shall satisfy themselves about condition, quality, quantity, and measurement

etc. of the entire materials, items, equipment & machinery, structures of the

Decommissioned Plant which they intend to purchase. No complaints shall be

entertained regarding description, quantity, quality, size, measurement, number and

weight as the information given in the catalogue is approximate and no warranty or

guarantee shall be implied. Materials shall be sold on “AS IS AVAILABLE BASIS

AND NO COMPLAINT BASIS” and on the

assumption that the bidders have inspected the entire Decommissioned Plant thoroughly

physically at all the areas of the site and know what they are buying, irrespective of

whether the bidders have physically inspected the site prior to e- auction sale or not; the

principle of “CAVEATEMPTOR” shall apply. Error in the description/ quantity/ quality/

measurement/ utility/ number/ weight/ condition etc. of the material as given in the

catalogue/ list published on the Auctioneer‟s website shall not form a cause to the bidder

to complain or to avoid completed sale or bid.

9.8 CAVEAT EMPTOR:

i. The quantity, quality, measurement and condition of the materials indicated are all

approximate. Participation and bidding by anyone in this sale shall be treated as

conclusive evidence of the fact that the party has inspected the entire materials,

items, equipment & machinery, structures of the Decommissioned Plant offered for

sale and satisfied himself in all respect regarding quantity, quality, measurement,

weight and condition of materials, taxes and duties, local working condition and

other extraneous factors and principle of Caveat Emptor (let the Buyer beware) will

apply.

ii. It shall be implied and taken for granted that the party has carefully gone through

and understood the terms and conditions of e- Auction including the amendments if

any, prevailing at the time of bid. No complaints or objections

Page 95: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

95

shall be entertained by PVUNL and / or the Authorities.

iii. PVUNL do not give any warrantee or guarantee for the quality, chemical

composition of each individual items in the lot or about the end use or fitness for a

particular purpose.

IN CASE BIDDERS COME ACROSS ANY MATERIAL BEYOND THE

SCOPE OF THE DESCRIPTION OF MATERIAL, IT SHOULD BE

INFORMED TO SELLER/MSTC. MSTC WILL NOT BE RESPONSIBLE

FOR ANY COMPLAINT IN THIS REGARD. BUYERS ARE ALSO

REQUESTED TO VISIT DIFFERENT SITES SUCH AS TURBINE AREA,

BOILER AREA, ELECTRICAL AREA, COOLING TOWERS, CHIMNEY

AND OTHER BUILDING STURCTURES BEFORE BIDDING.

Page 96: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

96

10. TERMS AND CONDITIONS OF SALE OF DECOMMISSIONED PLANT

10.1 Non-Acceptance of Bid

Bidders have to quote for the entire lot together in this e-auction and bids for part of lot or with

any attached condition shall not be considered. Further it will be at the sole discretion of

PVUNL to accept or cancel the sale without assigning any reason.

10.2 Pre-Bid Earnest Money Deposit/Earnest Money Deposit (EMD):

10.2.1 The bidder should deposit Pre-Bid Earnest Money Deposit of INR 8,00,00,000/-(Indian

Rupees Eight Crores) through MSTC e-payment gateway. The Pre-Bid EMD of unsuccessful

bidders shall be returned by MSTC within 15 calendar days after the completion of e-auction

without any interest. For successful bidder, the Pre Bid EMD may be converted as part of

Security Deposit or the same may be returned once Bank Guarantee in lieu of Security

Deposit is submitted as per Cl No 10.3 below.

10.2.2 If a bidder withdraws its bid after submission or fails to deposit EMD within the

stipulated time, the pre bid EMD of such bidder shall be forfeited without any further notice

to him.

10.2.3 The status of the highest bid accepted on STA (Subject To Approval) basis must be

personally seen by the bidders online through the link “Auction Lot Status”.

10.2.4 Bidders must always keep their registered email account valid and keep a watch on their

incoming emails for their own convenience. Non- payment or delay in payment of post bid

EMD on the plea of non-receipt of SIL (Sale Intimation Letter) will not be entertained by

MSTC.

10.3 Security Deposit

Interest free Security Deposit @ 10% of final e-auction price offered by the successful bidder

(Sale value without taxes & duties and TCS) is to be deposited to MSTC by successful bidder

within 10 calendar days of issue of intimation about acceptance of its auction bid.

Alternatively, Bank Guarantee of an amount equal to 10% of the final e-auction price (Sale

Price without taxes & duties and TCS) is to be submitted to PVUNL by the successful bidder

within 10 calendar days of issuance of Sale Intimation Letter by MSTC. The above

security deposit / BG will be returned by PVUNL only after three months of successful

completion of the job (contract) i.e.33 months in all respects including dismantling of

foundations to zero level and filling of the hollow places/ craters as a result of dismantling to

surface/ground level.

If any extension with/without penal rent is granted, the above BG shall also be extended for

the corresponding period i.e upto & including 3 months beyond the completion of extended

period. No interest whatsoever will be paid on the said security deposit by PVUNL /MSTC

Ltd.

Security Deposit (without interest)/ BG will be released only after completion of site

clearance and issuance of No-Objection Certificate from PVUNL. Getting the No- Objection

Certificate issued would be the sole responsibility of the Buyer, and therefore, the Buyer /

Page 97: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

97

bidder shall not hold MSTC/PVUNL responsible for it in any case. IT IS TO BE NOTED BY

THE BUYER THAT ISSUANCE OF NOC BY PVUNL WILL TAKE SO ME TIME

AFTER COMPLETION OF SITE CLEARANCE.

10.4 Inspection Decommissioned Plant is sold on AS IS WHERE IS AND NO COMPLAINT BASIS

condition and all items, materials, equipment, machinery, structures, debris generated out

of dismantling civil structures are to be removed and taken from the site by the Buyer

without any condition within the overall completion period of 30 months.

The entire materials, items, equipment & machinery, structures of the

Decommissioned Plant offered for sale may be inspected by interested bidders as per

the catalogue during day hours of working days by observing the entry procedure of

PVUNL, Patratu. Interested bidders may contact PVUNL, Patratu with the following:

-

i. Mr. FaizTaiyab , AGM (De-Commissioning), Mob:7759903977, email id :

[email protected]

ii. Mr. S K Das Kayasth, AGM(C&M), Mob.:9650992870,email id :

[email protected]

iii. Mr. Prakash Kumar Bhoi, DGM (C&M), Mob:7667509268, email id :

[email protected]

Efforts have been made that the entire materials, items, equipment & machinery,

structures of the Decommissioned Plant offered for sale shall be as per catalogue

however, some items may vary. The agency cannot claim for the missing items.

Therefore, the bidders are requested to check the material at site physically before

bidding.

The bidders should thoroughly satisfy themselves about the nature, specifications,

physical condition, quantity, quality, place of existence of the entire materials, items,

equipment & machinery, structures of the Decommissioned Plant and working

conditions at site. MSTC/PVUNL provides no guarantee or warranty as to the condition /

quality / fitness for any specific purpose or use. It should be clearly understood that no

claim / complaint about the quality, specifications, quantity, conditions or fitness for use

shall be entertained by MSTC/PVUNL once a bid has been registered into the e-auction

floor of MSTC.

NOTE: Interested Buyers are advised to get in touch with the above officers of PVUNL

and fix the date of inspection, to avoid any inconvenience during the Inspection period.

10.5 Sale Release Order The contract shall be treated as having been entered into as soon as the Acceptance Letter

is issued to the Successful Bidder by MSTC on behalf of PVUNL. The contract shall be

deemed to be completed when the Buyer clears the entire area by the removal of entire

material, scrap, debris etc., excavation of foundations and filling all the potholes to bring

the area to ground level. PVUNL shall certify the completion of the work on physical

inspection on the written request of the Buyer, when the job is completed by way of issue

of No Objection Certificate.

Page 98: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

98

10.6 Payments 10.6.1 100% payment i.e. Sale Price or final e-auction price of the successful bidder together

with prevailing taxes and duties plus TCS is to be deposited to PVUNL within 21 calendar

days from the date of issue of Acceptance Letter by MSTC. The above amount of sale shall

be paid by the Buyer through RTGS/NEFT on following a/c:

Name of A/C : PATRATU VIDYUT UTPADAN NIGAM LIMITED

Bank Name : BANK OF INDIA

A/C No : 481521110000003

Type of A/C : CURRENT

IFSC Code : BKID0004815

Address : PATRATU, RAMGARH, JHARKHAND

10.6.2 The entire lot of Plant & Machinery including Civil Structures has been divided into SIX (6)

segments keeping in view the locations and ease of dismantling and lifting of material of

various segments. Although the value of each lot has been equally divided i.e. 1/6th of the

total lot value but the actual worth of the material in each lot may not be same. This shall be

binding to the Buyer.

10.6.3 Against the Payment detailed at Sl No 10.6.1, segment allowed to be dismantled and

segment allowed to be lifted is as below:

Sequence

No.

ACTION REQUIRED TO BE TAKEN

Segment allowed

to be dismantled

Segment allowed to be

Lifted

1 Only first segment Only dismantled material of 1st segment

2 2nd

Segment &

remaining portion of earlier

segment

Only dismantled material of 2nd

segment and left over dismantled

material of earlier segment

3 rd

3 Segment & remaining

portion of

earlier segments

Only Dismantled material of 3rdsegment

and leftover dismantled material of

earlier segments

4 4th

Segment and remaining

portion of earlier segments

Only Dismantled material of 4th

segment and left over dismantled

material of earlier segments.

5 5th

Segment and remaining

portion of earlier segments

Only Dismantled material of 5th

segment and left over earlier

segments.

6 Entire listed material in

segment 1 to 6.

All the dismantled material,

including the left over material

of the previous segments

10.6.4 Instead of making 100% payment together with taxes & duties and TCS at the beginning of

the Contract as specified at 10.6.1, the Buyer may choose to make payment in 6 installments

as per schedule given at 10.6.6 below. In case of installment payment, interest @12.60% will

Page 99: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

99

be charged on the value of installment for a period counted from 21stday of issue date of

Acceptance Letter/Sale Order by MSTC to the date of payment within the last day for receipt

of that particular installment. The cost of material, along with all applicable taxes & duties

and TCS shall be paid by the Buyer in six equal installments through NEFT/RTGS to

PVUNL, Patratu on a/c detail provided at Cl No 10.6.1 above. However, if the Buyer chooses for

installment payment and at a later stage decided to pay balance full payment, he will be permitted

to do so without interest on the balance payment. However, no refund of the interest already paid

along with the premium installment will be done.

10.6.5 MSTC Ltd shall issue the delivery order, on production of proof of remittance of payment to

the PVUNL‟s A/C by Buyer and confirmation of receipt of payment from PVUNL and all the

statutory documents required (if any) from the Buyer The lifting order/Sale Release Order shall

be issued by PVUNL on receipt of all the statutory documents required (if any) and delivery

order from MSTC Ltd. The Buyers shall have option to deposit all the required statutory

documents directly at PVUNL‟s office or at MSTC office.

10.6.6 First installment shall be deposited within 21 calendar days from the date of issue of

Acceptance Letter/Sale Release Order (including date of issue) by MSTC. It would, however,

be obligatory on the part of the Buyer to deposit the 2nd, 3rd, 4th, 5thand 6th installments

within the period mentioned here under:

S

No

Payment

Inst. Payment Amount

Period from the date

of issue of

Acceptance

Letter/Sale

Release Order

1 1st 1/6th of the total sale value + interest+ taxes Within 21 calender days

2 2nd 1/6th of the total sale value + interest+ taxes Within 4 months

3 3rd 1/6th of the total sale value + interest+ taxes Within 8 months

4 4th 1/6th of the total sale value + interest+ taxes Within 12 months

5 5th 1/6th of the total sale value + interest+ taxes Within 16 months

6 6th Balance Sale Value + taxes Within 20 months

Example: Let the Sale Price be INR 120 Lakhs. Then installment values (in INR Lakhs) will be:

Instalment

No. (A) Period (B) Installment

Amt. in INR

Lakhs (C)

Balance

Instalment

amt. in INR Lakhs(D)

Int. @ 12.60% upto

next installment in INR

Lakhs

(E= D *12.6%*4/12)

Installment

payable in

INR Lakhs

(F= C+E)

I Within 21 calender days

20 100 4.2 24.2

II Within 4 months 20 80 3.36 23.36

III Within 8 months 20 60 2.52 22.52

IV Within 12 months 20 40 1.68 21.68

V Within 16 months 20 20 0.84 20.84

VI Within 20 months 20 0 0 20

120 12.6 132.6

Page 100: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

100

It would also be obligatory on the part of the Buyer to deposit the installment as per

schedule without any notice / reminder from PVUNL. After making the payment for

the first installment, the Buyer will be allowed to dismantle the material of first

segment only. The Buyer shall be allowed to lift the material of the first segment only

after deposit of 2nd installment with PVUNL. The dismantling and lifting schedule as

per the installment payments submitted by the Buyer is given in the following table:

Sr.

No.

Installments

ACTION REQUIRED TO BE TAKEN

Segment allowed

to be dismantled

Segment allowed to be

Lifted

1 On deposit of first

installment

Only first segment NO LIFTING SHALL BE

ALLOWED

2 On deposit of 2nd

installment

Only 2nd

Segment &

remaining portion

of 1st

segment

Only dismantled material of

first segment

3

On deposit of

3rdinstallment

Only 3rdSegment &

remaining portion

of

earlier segments

nd

Dismantled material of 2 segment

and left over dismantled material of

first segment,

4 On deposit of 4th

installment

Only 4th

Segment

and remaining

portion of earlier

segments

Dismantled material of 3rd

segment

and left over dismantled material

of the first two segments.

5 th

On deposit of 5

Installment.

Only 5th

Segment

and remaining

portion of earlier

segments

Dismantled material of 4TH

segment and left over

dismantled material of the

first three segments.

6 th

On deposit of 6

Installment and

balance if any.

Entire listed

material in

segment 1 to 6.

All the dismantled material,

including the left over

material of the previous

segments

10.6.7 The rates must be quoted exclusive of all taxes, duties and other levies etc. The GST (Goods

& Services Tax) rate prevailing at the time of execution shall be applicable. In case any other

levy/ duties etc. are imposed by Central/ State Government of Jharkhand / Local Authorities,

the same shall have to be borne by the Buyer. Bidder shall submit this / their Income Tax

Clearance Certificate (latest), partnership deed of organization as and when demanded by

MSTC/PVUNL.

10.6.8 The Buyer may clearly note that all the taxes, duties, levies, etc., if any are levied/ imposed by

any Statutory Authority till the final conclusion of the contractual period / contract shall be

Page 101: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

101

borne by him / them including the inter-state transactions and PVUNL shall not be responsible

to pay the same, if any, since the sale is on „AS IS WHERE IS AND NO COMPLAINT

BASIS”.

10.7 Late Payment Penalty It shall be in the interest of the Buyer to pay all the installments well within the stipulated

payment schedule. However, in case of default in payment within the stipulated time, Late

Payment Penalty @ 1% per week or part thereof for the full material value as per

10.6.1 or for the full material value of that installment (i.e. 1/6 thof the total sale value plus

interest plus taxes) as per Cl No 10.6.6 above shall be charged up to four (4) weeks of delay

in payment. Acceptance of late payment beyond four weeks and thereafter shall be at the

sole discretion of PVUNL. However, PVUNL reserves the right not to accept the payment

with or without the additional penalty after the expiry of the above mentioned due time limit

of four (4) weeks in each segment and in such an event the contract shall be liable to be

terminated and the Earnest Money / Security Deposit of the bidder together with any

payment deposited shall automatically stand forfeited without prejudice to the right of

PVUNL to dispose off the remaining materials, items, equipment & machinery,

structures of the Decommissioned Plant at the risk and cost of the Buyer and realize the

deficit, if any, from the Buyer. However if the sale value of the remaining items is more

than the amount due from the Buyer, nothing will be paid to the Buyer. If PVUNL allows to

accept the payment of installment after four weeks with additional penalty, then additional

2% per week or part there of shall be charged i.e. a total of 3% per week or part thereof.

10.8 Statutory Taxes & Duties

The Buyer shall be responsible to pay all the statutory taxes & duties at prevailing rate as

declared by the respective Local Bodies/State/ Central Government Authorities due in

respect of this sale. If the Buyer claims exemption/concession in the statutory taxes, he

shall furnish the necessary declaration in that respect. If, competent authority of PVUNL

allows the Buyer to lift the goods in multiple installments and make the payments

accordingly, the statutory taxes in such cases shall be paid on the proportionate sale price of

each installment along with payment of corresponding installment. The rate of applicable

taxes & duties shall be indicated against individual lot in the list displayed on the e-auction

site. However, the Buyer at the rates applicable shall pay statutory taxes & duties at the time

of delivery.

10.9 Authorization/ Identity The authorized representative of Buyer shall produce the authorization /identification letter

issued by the Successful Bidder while depositing amounts of security deposits, balance

payments and also while lifting the concerned lot.

10.10 Delivery

10.10.1 The completion period for the listed items of the plant including dismantling, cutting,

bringing down to ground level and taking out from PVUNL premises and leveling the

Page 102: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

102

surface to ground level is 30 months from the date of issue of Sale Release Order by PVUNL

issued against Delivery Order of MSTC. Please note that bringing the entire area to

ground level / base level requires sufficient time. This factor may be kept in mind while

taking out of all the scrap. (Buyer to take necessary margin for stopping of movement of his

trucks during traffic restriction and VVIP movement in the area). Note: -PVUNL shall not

entertain any requests from the Buyers regarding extension of payment period / delivery

period as stipulated in the Sale Release Order.

10.10.2 The dismantling and lifting schedule of the material will be item-wise in SIX SEGMENTS

as per the details of the material mentioned (refer the heading Sequence of Disposal).

10.10.3 Vehicles deputed for disposal of the material(s) should report for loading in early hours in

such a manner that requisite time is available for loading and vehicles are released before

closing of the working hours i.e. at 17:00 Hrs. No loading shall be permitted during lunch

hours (13:00hrs. to 14:00hrs) and after 17:00 hrs. Any relaxation in the above may be

considered by the PVUNL upon specific request by the Buyer. Bidder shall use only the

allocated security gate for entry and exit. The Gate no. may change at any time and shall be

binding to the Buyer.

10.10.4 The Buyer shall dismantle and lift the listed scrap material mentioned in the specified lots

allotted to them by employing their own labor and at its own cost. The material in all the

segments shall be lifted from the area within the prescribed period of 30 months allowed

from the date of issue of the Sale Release Order by PVUNL.

10.10.5 The material will have to be removed on “AS IS WHERE IS AND NO COMPLAINT

BASIS” and at the Buyer‟s own cost and expenses. No processing, whatsoever, other than

dismantling, required for convenient transportation, will be permitted by the PVUNL. The

Buyer shall not be provided with any work force or equipment. The Buyer would have to

arrange for all the tools and equipment insufficient quantity keeping in view the period

allowed for dismantling and transportation including Dozer, Scrapper, Cranes,

grinders, Cutters, Gas, Power or other facilities. While removing materials of one

segment, the other segment’s materials, for which payment has not been made, will not

be disturbed/damaged otherwise the Owner representative may impose penalty as

deemed fit in his/her opinion for the damage caused which shall be paid by the Buyer

along with the next instalment amount or recovered by encashing/ from EMD/Security

Deposit.

10.10.6 The agency / Contractor shall make his own arrangement of providing all facilities like

lodging, boarding, furniture & transportation etc. for his supervisors / labor engaged by him

for the job outside the premises of PVUNL.

10.10.7 Gas cutting work to be carried out in the course of dismantling will be allowed only under

the supervision of the Buyer‟s supervisory personnel who will ensure that all safety

precautions have been taken including those for prevention of fire and other safety hazard in

and around the area.

Page 103: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

103

10.11 Removal of Plant/ Machinery/ Equipment/ Items/ Debris Successful Bidder / Buyer will submit a plan to PVUNL for dismantling / demolishing,

transporting of dismantled materials / accessories, equipment from the site of work prior to

actual start of the work for PVUNL concurrence. The material stored / dismantled first

should be removed first. The time schedule and sequence of the dismantling & removal of

material shall be prepared by the Buyer as per the dismantling & lifting schedule & as per the

segments indicated and its prior approval shall be obtained from PVUNL. The approved

dismantling & lifting schedule shall be strictly adhered to.

10.11.1 Ground Rent: -It shall be in the interest of the Buyer to complete the entire work as per the

scope i.e. upto leveling of the ground within the stipulated period of 30 Months. However, in

case of default in lifting of the materials by the successful Bidder within the specified time

limits, the outstanding material would only be allowed to be lifted after payment of Ground

Rent for the period of delay beyond the specified due delivery period by the Buyer. The

Ground Rent is to be deposited in advance and in stages as required for a period of four

weeks (minimum) as per the below mentioned rates. However, the actual amount of Ground

Rent will be determined after completion of lifting of outstanding quantity and balance

amount, if any, will be refunded to the purchaser.

The completion of lifting of all the segments including the leveling of the entire ground

upto the entire satisfaction of PVUNL shall be confirmed / certified by PVUNL who will issue certificate to the firm for the same. The firm shall submit the written request for issue of the certificate after completion of entire work.

The Ground Rent shall be as under: -

i) For First Four weeks i.e. 1stto 4thweek from the permitted date - Ground

[email protected]% per week or part thereof of the total Sale Price (Without taxes).

ii) For Next Four weeks i.e. 5th to 8th week from the permitted date-Ground Rent

@0.10% per week or part thereof of the total Sale Price (Without taxes). th

For Next Four weeks, i.e., 9 to 12 week from the permitted date-Ground

[email protected]% per week or part thereof of the total Sale Price (Without taxes).

Note: GST/any statutory levy, applicable on Ground Rent shall also be payable by the

Buyer.

iv) The permission to allow the lifting with Ground Rent (as decided by the disposal

committee) beyond twelve weeks will be on the discretion of PVUNL whose

decision on Ground Rent shall be final and binding.

Please note that Ground Rent is applicable on the entire Sale Price/contract

value (Without taxes) and not on the portion, which has not been cleared. To

avoid Ground rent, the Buyer should make all out efforts to complete the job

within stipulated period of 30 months.

However, it will be the sole discretion of PVUNL to allow or not to allow the

Buyers(s) to lift the material with the ground rent after expiry of additional twelve

weeks beyond the stipulated due completion period of 30 months. In such event the

sale of the material not lifted by the Buyer(s) will automatically be cancelled and the

Page 104: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

104

Earnest Money /Security Deposit including payment of installment in full or part

made, as the case may be, will automatically stand forfeited. Further the Owner shall

have the absolute rights to dismantle and dispose off the remaining of the

Decommissioned Plant as deemed fit without any further reference / compensation to

the Buyer. In case of any debris/refuse/rejects left undisposed by the Buyer after the

expiry of scheduled completion period 30 months or any extended period, the same

shall be got done by the PVUNL at the risk and cost of the Buyer and the expenses

incurred thereupon shall be deducted from the Security Deposit.

10.11.2 Dismantling / Demolition & Disposal including transportation of the goods/materials/

Equipment shall be the responsibility of the successful bidder at his cost and risks, taking all

safety precautions. The Buyer shall demolish, dismantle and lift the entire material including

scrap material mentioned in the specified lot break up allotted to them by employing their

own labor and cost.

During dismantling / demolition, precautionary measures are to be taken to avoid any type of

damage to the systems linked with the other segment and any environmental pollution. If

there is any damage occurred, successful bidder (Buyer) is required to take immediate action

at their own risk and cost. The total material in the lot shall be lifted from the area within the

prescribed period.

10.11.3 The successful bidder/Contractor will arrange to remove the demolished and dismantled

material and clear the site as directed by PVUNL within the stipulated time.

10.11.4 The material will have to be removed on AS IS WHERE IS AND NO COMPLAINT BASIS

at the Buyer‟s own cost and expenses. No processing other than dismantling as may be

required for convenient transportation will be permitted at the sole discretion of the owner or

his authorized representative. The successful bidder shall not be provided with any

manpower or any equipment etc. by Owner (PVUNL) for dismantling/ demolition/loading/

unloading/transportations etc. of the materials. The successful bidder will have to arrange for

any or all of these at their own cost and they shall take prior permission from PVUNL

representative for this purpose. While removing one segment, the other segment should not

be disturbed/ damaged.

10.11.5 For heavier and longer consignments, the successful bidder shall arrange trailers with prime

movers through their own resources, as required. PVUNL shall not be responsible for any

delay occurring due to non-availability of trailers, etc. The successful bidder shall lift the

materials and site shall be cleared as per the direction of the PVUNL representative.

10.11.6 Civil structures of the plant are to be demolished up to ground level preferably by erecting

scaffolding etc. All the RCC Cooling Towers (Unit#7 to 10) and all four (04) number

chimneys shall be allowed to be demolished up to ground level by means of controlled

blasting or by erecting scaffolding or any other safe means etc. The Buyer shall obtain the

necessary clearances from all the concerned agencies for using explosives for demolition, if

any. All out efforts shall be made so that these structures fall-off downwards without

damaging the surroundings. The safety of man and machine is the sole responsibility of the

Buyer and his deputed agencies.

Page 105: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

105

10.11.7 PVUNL or its authorized representatives shall have the right to stop dismantling and loading

of the material if they feel that the Buyer or his representative is not following the

instructions given to them or the job is not being carried out in accordance with the

provisions of terms & conditions and/or Special Terms & Conditions and Buyer will be solely

responsible for the same.

10.11.8 Dismantle / Demolition and Disposal / removal of materials on pick and choose basis shall

not be allowed.

10.11.9 Dismantling / Demolition work and transportation of materials shall be done only during Day

Shift hours of PVUNL. No materials will be allowed to go out after 5.00P.M. on working

days. Similarly, no material will be allowed to go out on Sundays and holidays observed by

PVUNL. In case of requirement, any relaxation in the above may be considered as per the

discretion of PVUNL.

10.11.10 The Buyer shall make his own arrangement for the security of materials, items,

equipment & machinery, structures of the Decommissioned Plant sold to him i.e. with

effect from the start date of the contract. The firm shall take into his custody the entire lot

after satisfying himself with the material as per the lists supplied in the Auction Catalog

within 7 calendar days and shall furnish a certificate that the entire material has been taken

into the custody of the firm and now onwards firm shall make its own arrangement for

the security of the material. The custody of the entire material to the firm will be for the

purpose of security only and to confirm that all the material as per the list in the auction

catalog is available and thereafter PVUNL, in no way shall be responsible for any kind of

theft, misplacement, fire, etc.

10.11.11 The firm shall ensure that material of only those segment(s) shall be dismantled /

demolished or lifted as per the payment schedule and shall strictly adhere to. In case, firm is

found lifting / demolishing the material for which it was not eligible at that moment, the

penalty as decided by the PVUNL shall be imposed and be binding to the firm to pay. The

penalty can be extended even upto the cancellation of the contract, depending upon the

severity of the fault in view of the PVUNL. In that case, the entire BG / SD shall be

forfeited and no further demolishing / lifting shall be allowed. In case in any

material/building falling in the higher segment is causing hindrance and is absolutely

necessary to demolish the same to complete the demolish of lower segment, in that case

firm will submit a request to PVUNL to allow to demolish / dismantle the material /

structure of that higher segment. PVUNL will allow only keeping in view the genuineness of

the request and after submission of the payment of that segment

10.11.12 The Buyer will be allowed to post sufficient no. of security guards round the clock and the

names of the security guards will have to be made available to PVUNL so that Gate Passes

may be issued to them. PVUNL/MSTC shall neither be responsible for any theft of material

sold to the Buyer nor shall entertain any complaint on this account of whatsoever nature. The

Buyer will be responsible for the safe custody of his own tools, tackles and other materials

w.e.f. start date of the contract. PVUNL reserves the right to ask for removal of specific

security guard(s) whose activities are deemed unlawful or detrimental to PVUNL interests.

Page 106: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

106

The Buyer has to deploy alternative guards for the purpose.

10.11.13 Material shall be allowed to be taken out on valid Gate Passes, issued by PVUNL. These gate

passes shall have to be signed by authorized representatives of PVUNL as well as the Buyer.

The material shall only be allowed to go out from the Security gate earmarked and shall be

binding.

10.11.14 The Buyer shall not be allowed to store the material on the road sides or in any other way

which may cause hindrance or inconvenience to movement of public or vehicles.

10.11.15 No delivery of material would be effected by PVUNL to any persons other than the Buyer

or his authorized representative.

10.11.16 The Buyer shall comply with all statutory provisions as applicable.

10.11.17 All items covered under exclusions are property of PVUNL and not allowed to be

dismantled or lifted by the Buyer.

10.11.18 The Buyer has to demolish and remove the equipment / foundations / buildings / civil

structure upto the ground level. All holes, craters, hollow places and spaces created due to

dismantling / removal from minus meter levels including cable galleries and underground

pipe lines too have to be filled up with appropriate material to bring the surface to even

ground level.

10.11.19 Dismantling of plant, removing and sweeping of debris/waste arising out of dismantling

shall be carried out simultaneously. If at any time after the sale order / delivery order is

issued and PVUNL wants to retain any item / items for their own use, the Buyer will have to

release such items to be compensated by PVUNL as per assessment done, which shall be

binding on the Buyer.

10.11.20 Stacking and removal of dismantled material should be in a manner so as not to disturb the

normal working.

10.11.21 Buyer shall ensure that during dismantling/removal of materials no pollution is caused to

environment and will follow all pollution norms. COMPLIANCE OF MUNICIPAL SOLID

WASTE MANAGEMENT RULES, 2016 IS TO BE ENSURED BY THE BUYER.

10.11.22 Controlled Blasting for dismantling of Cooling Towers, Chimneys & foundations or

otherwise shall not be allowed, unless PVUNL provides prior special permission.

10.11.23 Barricading of areas / pits created after dismantling / excavation shall have to be done with

the materials that would be available after dismantling as per directive of the Owner or

their authorized representative.

10.11.24 DEMOLITION OF CIVIL STRUCTURES:

A. Utility Building, foundations of boilers, turbines, major auxiliaries etc.:

1. The Buyer has to demolish & remove the foundations/ buildings/ structures and level the

Page 107: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

107

ground upto the satisfaction of PVUNL, wherever the equipment / buildings / structures

are subject to sale.

2. All structures/ equipment/ RCC are to be dismantled to ground level / base level and all

debris to be cleared off from the site.

3. For dismantling of foundations, explosion will not be allowed (except for special cases).

However, the agency can use pneumatic hammers for breaking the hard foundations of

turbines, ID/FD Fans, Condensers, stack, boiler, etc.

4. The Buyer shall arrange to dump the debris/ waste material at an authorized dumping

place at his cost & risks.

B. Cooling Towers &Chimneys: -

1. Cooling Towers (Unit #7 to 10) & Chimneys (04 nos.) are to be demolished upto ground

level by way of controlled blasting or erecting/scaffolding etc. The Buyers shall arrange

to dump the debris/ waste material at an authorized dumping place at his cost &risks.

2. The scaffolding, if needed, shall be certified before use following any adverse weather

conditions or following any damage/ incident related to the structure.

3. Necessary safety precautions for the working staff should be taken such as safety belts,

oxygen kits etc.

4. Systematic process of dismantling shall be adopted.

5. Fire brick linings shall be removed manually collection from top to bottom and lowering

by lift as safety measure.

6. Explosiveness and presence of hydrocarbons shall be checked before dismantling.

7. Dismantling of chimneys shall generate a mix of building material, containing bricks

& concrete. This shall be removed.

8. Dismantling of chimneys may generate glass wool insulation/ asbestos waste. Such

waste shall be disposed off as per statutory rules for disposal of such items and in

compliance to Environment Norms.

9. Before starting of dismantling of Cooling Towers & chimney, a work out plan is to be

submitted to Decommissioning Department of PVUNL for their clearance/guidelines.

10. For dust mitigation required for Civil structure (esp. Chimney and Cooling Towers),

PVUNL shall provide a source of water from where the Agency shall have to make

arrangements for dust suppression system. The system needs to be effective and tested

before actual demolition as the entire area of demolition is surrounded by new project

construction area.

C. Boiler and Turbine Auxiliaries: -

1. Waste generating out of dismantling activities such as debris, glass wool etc. shall be

removed as per statutory rules for disposal of such items and in compliance to

Environment Norm.

2. The EOT Crane installed in the TG Hall shall be provided for the dismantling of TG sets

in MPH. However, agency has to arrange for its operator and breakdown maintenance if

required.

10.12 Engagement of Labour 10.12.1 The recruitment of labour should be in accordance with the labour laws of Central

Page 108: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

108

Government/State Government.

10.12.2 The Buyer will be required to declare the names of their authorized representative,

supervisors and working force and make available a register at site bearing their names,

photos, designations, rate of pay, permanent and local addresses, phone No. etc with their

authorized site in-charge.

10.12.3 The entry of the employees of the Buyer shall be regulated through the valid gate passes

issued by CISF, PVUNL at the request and verification of the Buyer and on the

recommendation of the Engineer-In-charge at site. All rules enforced from time to time in

this respect shall have to be followed by the Buyer.

10.12.4 The payment of monthly wages to the labour/staff of the Buyer, as per the Labour Laws and

for all the claims/compensation/damages will be the sole responsibility of the Buyer. Agency

must ensure payment of minimum wages as per Central Govt wage rate which is subject to

revision from time to time.

10.12.5 It shall be the responsibility of the Buyer to fulfill all statutory obligations in respect of labor

laws and therefore, shall keep PVUNL indemnified for all the consequences in case of any

default of any kind in this regard.

10.12.6 The Buyer shall not deploy any labour less than 18 years of age for any of the above work at

the Plant of PVUNL.

10.12.7 The labour and other supervisory staff shall use the necessary PPEs like helmets, gloves,

glasses, safety belts, safety nets, full body harness etc. for their safety. Agency must comply

to all PVUNL safety rules and regulation applicable within the premises of PVUNL.

10.12.8 PVUNL shall not be legally or otherwise responsible for any accident fatal/non-fatal.

10.12.9 The Buyer shall deploy sufficient qualified safety supervisor all the time at site to ensure that

all requisite safety precautions including use of PPE are in place.

10.13 Indemnity Damages and Insurance

10.13.1 The Buyer shall indemnify PVUNL for all acts/commissions or omissions of their

Engineers/officials, their agents or employees from and against all losses and all claims,

demands, payments, suits, actions, recoveries and judgments of every nature and description

brought or recovered from PVUNL during execution of the work. An indemnity bond to this

effect in the form as approved by PVUNL will be submitted to Decommissioning

Department by the Buyer before start of the work.

10.13.2 The Buyer shall also indemnify PVUNL against payment under the employee‟s

compensation act., which PVUNL / MSTC may suffer, sustain or be in any way subjected to

be reason of injuries to the Buyer‟s or the PVUNL employees, or other person or damage to

the property of any person or corporation arising out of or resulting from the performance of

the work of this contract.

10.13.3 Employees‟ compensation policy shall contain waiver of the insurer‟s right under the

employees‟ compensation law to recover from the owner compensations and other expenses

paid for any injury to or death of any employee of the purchaser which is performing be

covered by the contract.

10.13.4 FORCEMAJEURE: -

The delay in the completion of the work may be treated as force majeure to the

Contractor only if: -

Page 109: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

109

i) The delay is resulted from any causes arising out of compliance with regulations,

orders or instructions of the Central or State Governments, acts of God, acts of Civil

& Military authority, fires, floods, strikes, lock- outs, freight embargoes, war-risk riots

and civil commotion.

ii) If the delay is the result of reasons exclusively attributable to PVUNL.

iii) The Contractor‟s request for extension of the contract period along with all necessary

evidence comes, before the expiry of the schedule date of completion of work.

10.13.5 The Buyer shall pay all costs and maintain throughout the period of the contract, public

liability and property damage liability insurance with the following coverage: -

i) Public liability limits for bodily injury and death not less than Rs.2,00,000/- and Rs.

5,00,000/- per person for each accident respectively.

ii) Property Damage liability limit for each accident not less than Rs. Two Lacs.

10.13.6 The owner shall have the right at any time to require public liability insurance and property

damage liability greater than those specified. In any such event, the additional premiums

payable solely as the result of such increase in insurance shall be added to the contract sum.

10.13.7 In addition, the Buyer is fully responsible for all the equipment and material for damage or

loss from any cause during transition and/or while in custody of Buyer at his works site until

his complete work is formally accepted by PVUNL.

10.13.8 The Buyer shall submit insurance policy for entire duration of contract for “Dismantling of

machinery under CONTRACTOR‟S ALL RISK POLICY for sum insured value equal to

contract award value plus damage / theft / pilferage to surrounding property for sum insured

value Rs. One Crore favoring PVUNL and be handed over to PVUNL before start of work at

Site.

10.13.9 The Buyer must submit to the PVUNL insurance policy valid upto 33 months & shall be

extendable as per requirement of PVUNL. The Buyer shall name PVUNL in each policy in

addition to himself as the insured. Selection of the Insurance Co. shall be with the approval of

PVUNL from amongst the Govt. insurance companies (The New India Assurance Co. Ltd. /

Oriental Insurance Co. ltd. / National Insurance Co. Ltd / United Insurance Co. Ltd.)

10.14 Provident Fund/ Esi Registration

The successful bidder will be required to furnish the provident fund code number in respect

of provident fund contribution by the firm against the wages to their employees deputed for

work and should also be registered under ESI as per statuary Act / Rules. The successful

bidder has to submit copy of challan for depositing contribution to these agencies along with

his bill to PVUNL, if applicable, every month.

10.15 Safety

Safety of man, machines and environment is of utmost importance to PVUN. All precautions

must be taken to ensure safe dismantling, storage, transportation and disposal of the plant,

machinery, or any civil structure.

The Buyer shall be responsible to follow safety instructions as per the safety permit issued to

him and other safety regulations of PVUNL / State Govt. and will ensure that no accident or

Page 110: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

110

damage to either man or machine inside the PVUNL premises takes place. Any loss/ accident

on this score will be dealt in accordance with the Factory rules and Buyer shall be liable for

the same.

Any loss / damage caused to the property of the PVUNL has to be made good by the Buyer

as per the assessment of PVUNL management whose decision shall be final and binding on

the Buyer.

Gas cutting work to be carried out by the Buyer in the course of dismantling work etc. will be

allowed only under the supervision of the Buyer‟s qualified safety supervisory personnel,

who will ensure that all safety precautions have been taken including those for prevention of

fire in and around the area. Any loss on account of fire shall have to be borne by the Buyer.

The Purchaser shall ensure that his employees does not affect the Project Activities relating to

ongoing 3 x 800 MW Thermal Power Plant & do not loiter around within the plant premises

of PVUNL. They shall not touch any material except that material shown to them. If any of

his employees is even found violating these restrictions, the Buyer shall be responsible for

making good the loss to the owners on which their decision shall be final and binding.

10.15.1 SAFETY PROVISION RELATING TO CONTRACTOR

i. The Contractor / Buyer shall incorporate the safety provisions of clause 10.15 of auction

catalogue & direction of authorized Safety officer of PVUNL. Same are required to be

complied by Contractor‟s employees during execution of the contract to facilitate safe

working during execution of the work.

ii. The Contractor/Buyer shall observe the safety requirements as laid down in the clause 10.15

of auction catalogue that all safety compliances are fulfilled by the employees and staff of

the sub-Contractor.

iii. The Contractor / Buyer shall have a qualified Safety Supervisor who shall deal all the matters

relating to safety and his name shall be displayed on the notice boards at a prominent place at the

worksite. The Safety Supervisor should have experience in Deep Excavation, Scaffolding, hot

work, heavy equipment movement, enclosed space, gas cutting, welding , material Lifting

and Rigging, Site transportation, Construction power setup, electrical safety, working at

height, tall structure, working at Overhead High Tension Transmission Towers. For

imparting training to the workers, he must maintain the details along with their

photographs.

iv. While dismantling oil lines of HFO and LDO and their tanks, Contractor shall ensure deployment

of qualified workmen under the supervision of qualified Safety Supervisor. It will also be ensured

to put firefighters at the work place to avoid any fire hazard.

v. Work permits shall be issued by PVUNL executing department only after a joint visit is

conducted to ensure the area is safe for work. Permits shall be received only by the safety

supervisors of the agency after ensuring that the area is safe for its workers. Agency has to

take all measures to ensure the safety of the working area; for instance, purging of closed

ducts may be required before starting work or disposal of acids may be required before

dismantling of storage tanks. Agency must be prepared to carry out such works if required at

site. Decommissoning department of PVUNL shall guide for such precautionary measures

based on site requirements. All hazardous material such as asbestos, acids, insulation glass

wool etc. shall have to be disposed by the agency as per Environment norms and legal

Page 111: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

111

procedures for disposal of those items.

vi. The Contractor/Buyer shall be responsible for non-compliance of the safety measures,

implications, injuries, fatalities and compensation arising out of such situation or incidents. vii. In case of any accident, the Contractor shall immediately submit a statement of the same to

the Owner and Safety officer, containing the details of the accident, any injury or casualties,

extent of property damage and remedial action taken to prevent recurrence and in addition,

the Contractor shall submit a monthly statement of the accidents to the owner at the end of

each month.

10.15.2 OTHER SAFETY CLAUSES/ PROVISIONS

i. The Contractor / Buyer shall comply with all the requirements of respective regulations.

Regulation of Employment & Conditions of Service Act, and its Central Rule / State Rules

and any other statutory requirements as applicable.

ii. The Contractor / Buyer shall follow PVUNL Safety Rules as issued from time to time with

respect to safety in construction & erection.

iii. The Contractor/Buyer shall have the approved Safety, Health and Environment(SHE)

guideline in respect of Safety and health of Workers and it shall be circulated widely and

displayed at common places in English and local language understood by the majority of the

workers. A copy of the safety guideline should be submitted to Head of the Project.

iv. The Contractor / Buyer shall submit JSA / the safety plan comprising of methods to

implement the Safety guideline / Rules, Risk assessment and ensuring Safety at work areas,

Safety audits, inspections and its compliance, Supervision and responsibility to ensure

Safety at various levels, Safety training to employees, review of Safety and accident

analysis, ensure Health and Safety Procedures to prevent accidents to Head of the Project

for approval.

v. The Contractors / Buyer shall ensure proper safety of all the employees, materials, plant and

equipment belonging to him or to the Employer or to others, working at the Site.

vi. All equipment shall be strictly operated and maintained by the Contractor in accordance with

manufacturer‟s operation manual. The Contractor should also follow Guidelines / Rules of

the Employer in this regard.

vii. The Contractors / Buyer shall provide suitable latest Personal Protective Equipment of

prescribed standard to all their employees and employees according to the need. The

Engineer I/C, Head of the station / Project shall have the right to examine the safety

equipment to determine their suitability, reliability, acceptability and adaptability. The

Contractor / Buyer should also ensure these before their use at work site.

viii. The Contractor/Buyer shall provide safe working conditions to all employees and

employees at his workplace including safe means of access, railings, stairs, and ladders,

scaffolding, work platforms, toe boards etc. The scaffoldings shall be erected under the

control and supervision of an experienced and competent person having at least 05 years of

experience in this field. Upon demand, the experience certificate in the field of erecting

scaffolding may be provided to EIC or his representative. For erection of scaffolds, access,

work platforms etc. shall be good and the Contractor shall use standard quality of material.

ix. The Contractor/Buyer shall have his own arrangements with nearby hospitals for shifting

and treatment of sick and injured. Agency has to deploy a good quality Ambulance during

working hours at the work place.

Page 112: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

112

x. Their health records shall be maintained accordingly and to be submitted to PVUNL when

asked for. If any worker found suffering from occupational health hazard, the worker should

be shifted to suitable place of working and properly treated under intimation to Engineer

I/C, Head of the Station/Project. The medical fitness certificate to be submitted to Engineer

(I/C). Head of the Station/Project.

xi. First Aid boxes equipped with requisite articles as specified in the Rules for the use of

workers. Training has to be provided on first aid to employees & office bearers working at

site.

xii. Emergency Action Plan: – The Contractor shall prepare an emergency action plan and is to

be approved by his competent authority to handle any emergency occurred during

dismantling work. Regular mock drills shall be organized to practice this emergency plan.

The Emergency Action Plan should be widely circulated to all the employees and suitable

infrastructure shall be provided to handle the emergencies.

xiii. Scaffolding: -The Contractor/Buyer shall take all precautions to prevent any accidental

collapse of scaffolding or fall of persons from scaffolding. The scaffolding shall meet the

required strength and other requirements for the purpose for which the scaffold is erected.

xiv. Opening: -The Contractor / Buyer shall ensure that there is no opening in any working

platform/any floor of the building, which may cause fall of workers or material. Whenever

an opening on a platform / any floor of the building is unavoidable, the opening should be

suitably fenced and necessary measures for protection against falling objects or building

workers from such platform are taken by providing suitable safety nets, safety belts or other

similar means.

xv. Explosives: -The Contractor/Buyer shall take all precautions while handling, using, storing

or transporting of all explosives. Before usage of any explosive necessary warning / danger

signals are erected at conspicuous places to warn the workers and general public. The

Contractor should strictly ensure that all measures and precautions required to be complied

for use, handling, storing or transportation of explosives under the rules framed under the

Explosives Act,1884.

xvi. Dangerous and Harmful Gases / Equipment: -The Contractor/Buyer shall ensure that

the workers are not exposed to any harmful gases during any activity including excavation,

tunneling, confined spaces etc. The Contractor / Buyer should not allow any worker to go

into the confined space unless it is certified by PVUNL to be safe and fit for the entry. The

Contractor should not go for gas cutting of any confined drums, vessels, containers etc.

where there is supposed to have harmful gases or inflammable liquids/gases.

xvii. Overhead Protection: -The Contractor / Buyer shall ensure that any area exposed to risk of

falling materials, articles or objects is roped off or cordoned off or otherwise suitably

guarded from inadvertent entry of any person. Wherever there is a possibility of falling of

any material, equipment or workers while working at heights, a suitable and adequate safety

net should be provided. The safety net should be in accordance with BIS Standards.

xviii. Handling of Hazardous Chemicals: -The Contractor / Buyer will notify well in advance to

the PVUNL of his intention to bring to the Site any container filled with liquid or gaseous

fuel or explosive or petroleum substance or such chemicals which may involve hazards.

PVUNL shall have the right to prescribe the conditions, under which such container is to be

stored, handled and used during the performance of the works and the Contract shall strictly

adhere to and comply with such instructions. The Engineer I/C shall have the right at his sole

Page 113: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

113

discretion to inspect any such container or such construction plant / equipment for which

material in the container is required to be used and if in his opinion, its use is not safe, he

may forbid its use. No claim due to such prohibition shall be entertained by PVUNL and

PVUNL shall not entertain any claim of the Contractor towards additional safety provisions/

conditions to be provided for/ constructed. Further, any such decision of the Engineer I/C

shall not, in any way, absolve the Contractor of his responsibilities and in case, use of such

a container or entry thereof into the Site area is forbidden by PVUNL, the Contractor /

Buyer shall use alternative methods with the approval of the PVUNL without any cost

implication to the PVUNL or extension of work schedule. Where it is necessary to provide

and / or store petroleum products or petroleum mixtures and explosives, the Contractor shall

be responsible for carrying-out such provision and / or storage in accordance with the rules

and regulations laid down in Petroleum Act 1934, Explosives Act 1948 or its latest version

as applicable, and Petroleum and Carbide of Calcium Manual published by the Chief

Inspector of Explosives of India. All such storage shall have prior approval of the Engineer

I/C. In case any approvals are necessary from the Chief Inspector (Explosives) or any

statutory authorities, the Contractor shall be responsible for obtaining the same.

xix. Eye Protection: -The Contractor/Buyer shall provide suitable personal protective

equipment to his employees depending upon the nature of hazards and ensure their usage by

the workers engaged in operations like welding, cutting, chipping, grinding or similar

operations which may cause injuries to his eyes.

xx. Excavation: -The Contractor /Buyer shall take all necessary measures during excavation to

prevent the hazards of falling or sliding material or article from any bank or side of such

excavation which is more than one and a half meter above his footing by providing adequate

piling, shoring, bracing etc. against such bank or sides.

Adequate and suitable warning signs shall be put up at conspicuous places at the excavation

work to prevent any persons or vehicles falling into the excavation trench. No worker

should be allowed to work where he may be stuck or endangered by excavation machinery

or collapse of excavations or trenches.

xxi. Electrical Hazards: -The Contractor/Buyer should ensure that all electrical installations at

the dismantling /construction work comply with the requirements of latest electricity acts /

rules. The Contractor/Buyer shall take all adequate measures to prevent any worker from

coming into physical contact with any electrical equipment or apparatus, machines or live

electrical circuits which may cause electrical hazards during the dismantling construction

work. The Contractor shall provide the sufficient ELCBs / RCCBs for all the portable

equipment, electrical switchboards, distribution panels etc. to prevent electrical shocks. The

Contractor should ensure use of single / double insulated hand tools or low voltage i.e., 110

volts‟ hand tools. The Contractor / Buyer should also ensure that all temporary electrical

installations at the dismantling construction works are provided with earth leakage circuit

breakers.

xxii. Vehicular Traffic: -The Contractor / Buyer should employ vehicle drivers who hold a

valid driving license under the Motor Vehicles Act,1988.

xxiii. Lifting Appliances, Tools &Tackles, Lifting Gear and Pressure Plant & Equipment

etc. - The Contractor/Buyer shall ensure all the lifting appliances, tools & tackles including

cranes etc., lifting gear including fixed or movable and any plant or gear, hoists, Pressure

Plant and equipment etc. are in good condition and shall be examined by competent person

Page 114: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

114

and only certified shall be used at sites. Periodical Examination and the tests for all lifting /

hoisting equipment & tackles shall be carried out. A register of such examinations and tests

shall be properly maintained by the Contractor and will be promptly produced as and when

desired by Head of Project or the person authorized by him.

xxiv. Excessive Noise, Vibration: -The Contractor / Buyer shall take adequate measures to

protect the workers against the harmful effect of excessive noise or vibration. The noise

should not exceed the limits prescribed under the concerned rules, Noise Pollution

(Regulation and Control) Rules,2000.

xxv. Electrical Installations: -The Contractor/Buyer shall not interfere or disturb electric fuses,

wiring and other electrical equipment belonging to the Employer or other Contractors under

any circumstances, whatsoever, unless expressly permitted in writing by PVUNL to handle

such fuses, wiring or electrical equipment.

10.15.3 SAFETY ORGANIZATION

I. The Contractor/Buyer shall employ at least one full time qualified safety officer

exclusively to supervise safety aspects of the equipment and employees, who will

coordinate with the PVUNL Safety Officer. Further requirement of safety officers,

if any, shall also to be deployed by Contractor. In case the work is being carried

out through sub-contractor, the employees / employees of the sub- Contractor

shall also be considered as the Contractor‟s employees / employees for the above

purpose.

II. The name and address of such Safety Officer of the Contractor will be promptly

informed in writing to the Head of the Station / Project with a copy to the Safety

department before he starts work or immediately after any change of the

incumbent currency is made during of the Contract.

III. Reporting of Accident and Investigation:- In case any accident occurs during

the dismantling /demolition / de-erection or other associated activities

undertaken by the Contractor thereby causing any near miss, minor or major or

fatal injury to his employees due to any reason , it shall be responsibility of the

Contractor / Buyer or to promptly inform the same to PVUNL Safety

Department with a copy to PVUNL Head of Project in the prescribed form and

also to all the authorities envisaged under the applicable laws.

10.16 Right to Stop Work

10.16.1 The Engineer I/C shall have the right at his sole discretion to stop the work, if in

his opinion the work is being carried out in such a way that it may cause accidents and

endanger the safety of the persons and / or property, and / or equipment. In such cases,

the Contractor / Buyer shall be informed in writing about the nature of hazards and

possible injury / accident and he shall comply to remove shortcomings promptly. The

Contractor / Buyer after stopping the specific work can, if felt necessary appeal

against the order of stoppage of work to the Head of the Station/Project within 3

working days of such stoppage of work and decision of the Head of the

Station/Project in this respect shall be conclusive and binding on the Contractor.

10.16.2 The Contractor / Buyer shall not be entitled for any damages / compensation for

stoppage of work due to safety reasons and the period of such stoppage of work shall

not be taken as an extension of time for Completion of the Facilities and will not be the

Page 115: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

115

ground for waiver of levy of liquidated damages.

10.16.3 Fire Protection: -The Contractor/Buyer shall provide sufficient fire

extinguishers at place of work. The fire extinguishers shall be properly maintained as

per relevant BIS Standards. The employees shall be trained to operate the fire

extinguishers

/equipment.

10.17 Facility by PVUNL within the premises

10.17.1 At present, electricity for general lighting purposes only is available in the plant

premises and shall continue during the dismantling and lifting period also at no cost to the

Buyer. However, for any additional work for lighting / dismantling/ lifting purposes by the

Buyer, electricity, if available, the bidder has to take the electric connection on chargeable

basis from PVUNL / concerned agency. This can in no way be cited as any reason for

delaying / not carrying out dismantling/ lifting work by the Buyer. PVUNL shall not be

responsible for any disruption of supply caused due to dismantling work.

10.17.2 All arrangements of dismantling, removal, loading and transportation of the sold

material have to be made by the Buyer himself. PVUNL does not take any responsibility for

providing any consumables including oxygen/DA gas, welding rods etc. to the Buyer for

dismantling and lifting job.

10.17.3 Neither any arrangement for stay for any supervisor or employees shall be made by

PVUNL nor shall anyone except security guards of the Buyer, be allowed to remain inside

the plant premises during night or on any „off‟ day. Also washing of clothes etc. shall not be

allowed in the plant premises.

10.18 Security of Sold Equipment

a. The Buyer shall make his own arrangement for the security of materials sold to him

w.e.f. the start date of the contract. The Buyer will be allowed to post Security Guards round

the clock and the names of the Security Guards will have to be made available to PVUNL so

that Gate Passes may be issued to them. PVUNL will neither be responsible for any loss or

theft of material sold to the Buyer nor entertain any complaint on this account of whatsoever

nature. The Buyer will be responsible for safe custody of his own tools, tackles and other

materials w.e.f. start date of the contract. PVUNL reserves the right to ask for removal of

specific security guard/s, whose activities are deemed unlawful or detrimental to PVUNL‟s

interests. The Buyer has to deploy alternative guards for the purpose.

b. The Buyer shall be responsible for any damages that may be caused to the premises of

PVUNL while dismantling, storage or removal of the lot/ material purchased by him and

before removing such lots or items from PVUNL premises, the Buyer shall be liable to pay the

amount of damages assessed by PVUNL in this regard.

c. The Buyer shall abide by and will be responsible to follow all the Labour Laws in respect of

persons engaged by them. PVUNL shall not be responsible for any claims raised by their

personnel in respect of the e-auctions. The safety statutory measure shall be applicable during

entire contract period.

Page 116: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

116

d. Sale Release Order, Delivery Orders, Delivery Challans, Sale Release Orders, Lifting

Orders, Gate Passes, etc. shall be made in the name of actual Buyer only.

e. The Buyer shall insure the plant and equipment, his personnel and take cover for third party

risk if thought essential by him or if required by statutory regulations. Also, necessary

clearance from the statutory authority, if required, shall be obtained by the purchaser.

PVUNL will not be called upon to bear any responsibility in this regard. The Buyer shall agree

to keep PVUNL harmless and indemnified from and against all costs and expenses incurred

and all losses and damages suffered by PVUNL due to or as a result of any misrepresentation

or fraud on the part of Buyer and / or his employees or agents. The Buyer shall bear

insurance costs and maintain throughout the period of contract, public liability and property

damage liability in consultation with PVUNL.

f. In case of any accident during the contract period, in the premises of PVUNL, the

amount of compensation payable to the affected person/his family shall be assessed by

Statutory Authority and payable by the Buyer.

g. In case of damages to any equipment or property which is not covered in the contract, the

amount of compensation as assessed by PVUNL Authority shall be final and shall be

payable by the Buyer.

h. In respect of any dispute regarding material or regarding execution of contract that may arise

during contract period, the decision of PVUNL shall be final.

i. Whenever any claims for the payment of sum of money arises out of or under this sale against the

purchaser, PVUNL shall without prejudice to any other remedy, be entitled to deduct such sum of

money from the proceeds of sale under this contract or from any sum then due or which at any

time thereafter may become due to the Buyer under this or any other Contract with PVUNL and

if sufficient amount is not due to Buyer to cover the full amount recoverable from him, the Buyer

shall pay to PVUNL on demand the balance remaining dues or the BG submitted by Buyer will

be invoked.

j. It will be the sole responsibility of the Buyer, for any type of accident occurred during the

disposal / decommissioning / dismantling / transporting of the Unit No.1, 2, 3, 4, 5, 6, 7, 8, 9 &10 and associated auxiliaries.

k. The terminal points for dismantling during disposal of Unit No.1,2,3,4 ,5,6,7,8, 9 &10 will

be finalized by the PVUNL.

l. All safety precautions are to be taken by the Buyer & use of Personal Protective Equipment

(PPE‟s) will be mandatory while dismantling during disposal of units.

m. It will be the sole responsibility of the Buyer for any mishap/ theft in connection with the

allotted material & premises where the disposal units are situated.

n. The technical parameters indicated in the catalogue / nameplates are at the time of

installation of the units. These parameters like pressure / temperature etc. might have been

Page 117: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

117

derated due to old age. As such, PVUNL is not responsible for performance of these

machineries on account of such parameters indicated in the catalogue.

10.19 Labour/ Health/ Safety Conditions and Provision of Employees

Compensation Act I. In every case in which, by virtue of the provision of Sec. 12, Sub-Sec.(i) of the Employees

Compensation Act,1923 or any other law for the time being in force, if PVUNL is obliged to

pay compensation to an employee employed by the Buyer in execution of the works,

PVUNL is entitled to recover from the Buyer the amount of the Compensation so paid, and

without prejudice to the rights of PVUNL, Under Section -12, Sub-section (2) of the said Act

or any other law for the time being in force, except on written request of the Buyer and upon

his giving to PVUNL full security for all costs for which PVUNL might become liable in

consequence of the contesting such claim.

II. In addition to the above, in the event of death of the Buyer‟s employee while on duty, an

immediate ex-gratia payment of Rs. 10,000/- (Indian Rupees Ten Thousand only) should be

paid by the Buyer to the dependents of the employee. In case the Buyer fails to pay such

amount, as mentioned above, the PVUNL management may pay the amount to the deceased

employee‟s dependent and recover the amount from the Buyer.

III. It shall be the responsibility of the Buyer to fulfill all statutory obligations in respect of

labor laws and therefore, shall keep PVUNL indemnified for all the consequences in case of

any default of any kind in this regard.

10.20 Jurisdiction The Contract shall in all respect be construed and operated as an Indian Contract and in

accordance with the Indian laws in force and is subject to the exclusive jurisdiction of only

Jharkhand Courts at Ranchi.

10.21 Arbitration

All the matters, questions, disputes, differences and /or claims arising out or and / or concerning

and / or in connection and / or in consequences or relating to this contract whether or not

obligations of either of both parties under this contract be subsisting at the time of such dispute

and whether or not this contract has been terminated or purported to be terminated or completed,

shall be referred to the sole Arbitrator to be appointed by CEO, PVUNL. The award of the

Arbitrator shall be final and binding on the parties to this contract. Provisions of Arbitration and

conciliation act, 1996 and the rules made thereunder as amended from time to time shall be

deemed to apply to the Arbitration proceedings under this clause.”

10.22 Contact during execution of work

Throughout the contract period, Buyer shall keep his mobile phone (which Buyer has intimated at

the time of start of work) in active/operative condition. Further, mobile phone contact number of

the site supervisor shall also have to be intimated at the time of start of work and his mobile also

be kept in active/operative condition throughout the contract period. In case, under some

Page 118: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

118

emergency, contact could not be maintained on these intimated mobiles, under those

circumstances, PVUNL will recover Rs. 500/- per mobile per day till the mobile contact is again

made active / alternate mobile number provided to site-in charge. The Buyer shall also intimate

the e-mail accounts of himself and those of their authorized representatives at the start of the

work.

10.23 The Sale will be governed by the Material List, Terms & Conditions & Special Terms &

Conditions (STC) displayed on the Live e-Auction Floor (and not under forthcoming Auctions) as

well as the General Terms & Conditions (GTC) and Buyer Specific Terms & Conditions (BSTC)

already accepted by the Bidder at the time of e-Auction Registration with MSTC. The Material

List & STC displayed under View Forthcoming Auctions on MSTC's e-Auction Website are

tentative and subject to change at MSTC's sole discretion before the start of e- Auction. Bidders

should therefore download the Material List and STC displayed only under View Live Auctions

for their record purpose, if required. The BSTC and GTC can be seen and downloaded by going to

the Home Page of the e-Auction Website and clicking on NEW USER. Participation in the e-

Auction will be deemed to imply that the Bidder has made himself thoroughly aware of and

accepted the STC, BSTC and GTC. In case of any conflict between the STC and BSTC, the STC

shall prevail. MSTC shall have the right to issue addendum to the STC or BSTC, to clarify,

amend, modify, supplement or delete any of the conditions, clauses or items stated therein and the

Addendums issued shall form a part of the original STC.

10.24 The Principal / Owner of the materials reserves the right to withdraw at any stage of the sale any

item or quantity of material either by number or by weight or any other specific unit etc, even

after issue of Sale Release Order/Delivery Order. The Principal/Owner will not be bound to

assign any reason or details thereof. Value of the materials, as ascertained by PVUNL for the

materials so withdrawn, if any, and paid by the Buyer will be refunded. The Principal will

however, not be responsible for any damage, loss, direct or consequential compensation

whatsoever to the Buyer nor for payment of any interest.

10.25 PVUNL / MSTC reserves its right to demand copy of any other document / License / Certificate

issued by any Statutory / Govt. Authority in favor of the Bidder, if required, under any Statutory

or State / Central Government Act / Law / Order / Rules, etc.

10.26 Statutory requirement

The bidder shall abide by all Acts notified by the Govt. of India, Govt. of Jharkhand from time to

time to the extent they are applicable during the execution of the contract. Further, the bidder

should comply with all statutory requirement / clearances in respect of laws, regulations and

procedures governing this contract.

10.27 Blacklisting

If it is found that the Buyer is not following the terms and conditions of payment / delivery or

other conditions of the e-Auction and also indulging in any malpractices either himself or by his

agents, deputies or observer, such bidder is liable to be blacklisted for the appropriate period for

claiming the future business with PVUNL at the discretion of PVUNL and appropriate action

will be taken as deemed fit by PVUNL/ MSTC however before blacklisting, a Notice of 15

calender days will be given.

10.28 Law Governing Contracts

Page 119: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

119

All contracts shall be governed by the laws of India for the time being in force irrespective of

the place of delivery, place of performance or place of payment under a contract, the contract

shall be deemed to have been made at the place where the acceptance of the tender has been

issued i.e. PVUNL, Patratu.

10.29 Termination Clause

PVUNL can terminate the contract by giving 15 calender days‟ notice in case the work executed

by the Buyer is not satisfactory to PVUNL or Buyer makes a material default in performance of

contract. On termination, security deposit/BG submitted and /or any payment deposited by the

Buyer shall be forfeited.

Page 120: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

123

.

Annexure-I: Safety Guidelines

(Clauses mentioned hereunder are only supplement to the Safety Clauses at 10.15. In case of any difference, clauses

mentioned hereunder will prevail.)

Safety Clauses for Dismantling work

GENERAL

1. SAFETY SHALL BE THE TOP MOST PRIOTY OF EVERY STEPS OF DISMANTLING

WORK.LIFE IS PRECIOUS.ALL EFFORT SHALL BE MADE TO AVOID A SINGLE

INJURY EVEN FIRST AID. ALL NEARMISSES SHALL BE

ANALYSED AND SHALL BE REPORTED TO PVUNL SAFETY DEPARTMENT.

2. The Buyer shall comply the provisions of Factories Act 1948, THE BUILDING AND

OTHER CONSTRUCTION WORKERS‟ (REGULATION OF EMPLOYMENT AND

CONDITIONS OF SERVICE) ACT, 1996 and any other statutory provisions applicable to

them to ensure occupational health and safety. PVUNL Electrical & Mechanical Safety

Rules and any other Rules made by PVUNL relating to

Operation & Maintenance of plants. The Contractor shall make arrangements at all his work

places for ensuring safety and absence of risks to health of the works. THE WORKER AND EMPLOYEE

The employees employed by the Buyer should be skilled / competent in accordance with the

job requirement to be satisfaction of the Engineer-in-Charge shall have a right to remove any

employee of the Buyer whom he feels to be incompetent. The

Contractor shall employ sufficient number of supervisors to ensure supervision at all places

of his work at all the times. SAFETY ORGANIZATION

A The Buyer should have at least one qualified Safety Officer ( Diploma on Industrial Safety

from CLI and RLIs).Additional Number of Safety Officers shall be appointed per 250 nos workers

B Certificate regarding Qualification of Safety Officer/Officers shall be submitted to PVUNL

Safety Department and get it approved before to start of work. C Facilities and status of the Safety Functions shall be submitted along with Safety plan

5 SAFETY PLAN

The Contractor shall submit SAFETY PLAN indicating JSA or HIRA of the activities to be

undertaken and get it approved from PVUNL. 6 SAFETY AWARNESS AND TRAINING

A The Contractor shall arranged Daily PEP Talks / tool Box training to each group daily before

to start work.

B Each worker shall have Pre employment training and certificates in this regard shall be

submitted to PVUNL Safety Department.

C The Contractor shall arrange Post employment Training (minimum 1 day duration) for all of

his worker at least once of every six month report to be submitted to PVUNL Safety

Department.

D No tress shall be given to worker engaged during training. Salary, working lunch shall be

proved by Contractor. MEDICAL CHECK UP AND OCCUPATIONAL HEALTH CHECK UP

A The contractor shall provide premedical heath checkup of workers to be employed before to

start of work B Shall have First Aid medical facilities and competent First Aid attended.

C The Contractor shall have medical facilities and arrange occupational health checkup. Lung

function test is mandatory.

The necessary registers and records relating to the medical examination of all the

employees should be maintained and shown to PVUNL Engineer in-Charge / Safety-in-

Charge on demand 8 HEALTINESS OF EQUIPMENT

The Contractor shall ensure that the equipment / electrical installation system / facilities are

provided and maintained by him as required under various statutes. He shall also ensure

testing / examination of the equipment wherever required, in accordance with the

provisions of the Factories Act or any other prescribed status.

Page 121: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

124

The record of such inspection / testing and examination shall be kept at the site and shown to

PVUNL Engineer-in-Charge on demand. 9 WORKING AT HEIGHTS

A No work at Height shall be carried out without Check list clearance and Height Permit.

B All working platforms, ways and other places o area shall be free from accumulations of any

material causing obstructions and tripping.

C Every opening at elevation from ground level through which a worker, material, equipment,

etc. shall be covered and / or guarded suitable by the Contractor to prevent such falls.

D Wherever the works are exposed to hazards of falling from the height, the Contractor shall

provide full harness safety belts fitted with fall arresting system to the employees working at

the higher elevation and life line of 8mm diameter wire rope with turn buckets for anchoring

of safety belts while working or moving at higher elevations Safety nets shall also be

provided for saving them from fall from heights and such equipment should be in

accordance with BIS Standards.

E Wherever there is a possibility of failing of any material, equipment or workers while

working at heights a suitable and adequate safety net should be provided. The safety net

should be in accordance with BIS standards.

F The Contractor shall provide proper access like ladders, etc. where the workers are required

to reach higher elevations and ensure the workers and use them as an access for higher

elevations where a permanent access is not available. The workers shall be provided with

safety belts fitted with suitable for arresting system (Fall arrestors) for climbing / getting

down through ladders to prevent fall from height. 10 OPENING

The Contractor shall ensure that vessel, sump, tank, pit or opening in ground or in a floor

which by reason of its depth, situation, construction or contains or may be source of danger

at his workplace shall be either securely covered or fenced and necessary measures for

protection against falling materials / objects on workers from such platform are taken by

providing suitable safety nets, safety belts or other similar means.

11 FENCING OF MACHINERY

The Contractor shall not allow any worker to examine any part of the machinery or to carry

out the lubrication or other adjusting operation while the machinery is in motion. The workers

near the machinery in motion shall be provided with tight fitting clothes as required under

State Factory Rules.

12 SCAFFOLDINGS AND WORK PLATFORMS

The Contractor shall take all precautions to prevent any accidental collapse of scaffolding or

working platforms of fall of person from scaffolding or working platforms. The Contractor

shall ensure that scaffolding erection and repairs are done under the expert supervision. The

scaffolding shall meet the required strength and other requirements for the purpose of which

the scaffolding / work platform is erected. The material used for scaffold / work platform

should confirm to the BIS Standards. 13 CONFINED SPACE

No person shall be allowed to work without Permit and clearance of Checklist prepared for

this purpose. Prescribed Format of prepared by PVUNL is mandatory.

14 Explosives

The Contractor shall take all precautions while handling, using, storing or transporting of all

explosives. Before usage of any explosive necessary warning / danger signals are erected at

conspicuous places to warn the workers and general public. The Contractor should strictly

ensure that all measures and precautions required to be complied for use, handling, storing or

transportation of explosives under the rules framed under the Explosives Act, 1884

15 Excavation

The Buyer shall take all necessary measures during excavation to prevent the hazards of

falling or sliding material or article from any bank or side of such excavation which is more

than one and a half meter above his footing by providing adequate piling, shoring, bracing

etc. against such bank or sides.

Adequate and suitable warning signs shall be put up at conspicuous places at the excavation

work to prevent any persons or vehicles falling into the excavation trench.

Page 122: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

125

No worker should be allowed to work where he may be stuck or endangered by excavation

machinery or collapse of excavations or trenches 16 Vehicular Traffic

The Buyer should will deploy only such vehicle drivers who hold a valid driving license under

the Motor Vehicles Act, 1988. 17 RIGHT TO STOP WORK

A The Engineer-in-Charge/Contactor Safety Officer shall have right at his sole discretion to

stop the work, if in his option the work is being carried out / such a way that it may cause

accidents and endanger the safety of the persons and / or property and / or equipment. In such

cases, the Contractor shall be informed in writing about the nature of hazards and possible

injury / accident and he shall comply to remove shortcomings promptly.

B The Contractors shall not be entitled for any damages / compensation for stoppage of work,

due to safety reasons and the period of such stoppage of work shall not be taken as an

extension of time for Completion of the Facilities and will not be the ground for waiver of

levy of liquidated damages.

18 OVERHEAD PROTECTION

A The Contractor shall ensure that any area exposed to risk of falling materials, articles or

objects is roped off or cordoned off or otherwise suitable guarded from inadvertent entry or

any person.

B Wherever there is a possibility of falling of any material, equipment or construction workers while working at heights a suitable and adequate safety net should be in accordance with BIS Standards.

19 EYE PROTECTION

The Contractor should provide suitable personal protective equipment to his workmen

depending upon the nature of hazards and ensure their usage by the workers engaged in

operations like welding, chipping, grinding or similar operations which may cause injuries to

his eyes. 20 ELECTRICAL HAZARDS

A The Contractor should ensure that all electrical installations / equipments used in work area

comply with the requirements of latest electricity acts / rules.

B The Contractor shall take all adequate measures to prevent any worker from coming into

physical with any electrical equipment or apparatus, machines or live electrical circuits

which may cause electrical hazards during the construction work. The Contractor shall

provide the sufficient RCCBs for all the portable equipments, electrical switchboards,

distribution panels etc. to prevent electrical shocks to the workers.

C The Contractor should ensure use of single / double insulated / plastic body hand tools or low

voltage i.e. 110 volts hand tools.

D Wherever PVUNL Electrical and Mechanical Safety Rules prescribed, the Contractor shall not undertake any work till the permit is obtained for the specific work in accordance with PVUNL Rules.

E All electrical connections are to be taken by using plug top, no tapping of power by booking

will be allowed. 21 LIFTING TOOLS AND TACKLES

The Contractor shall use the lifting appliances, tools and tackles including cranes etc. lifting

gear including fixed or movable and any plant or gear, hoists, pressure plant and equipment

etc. are in good construction and examined by competent person and certified as per statutory

requirements. 22 REPORTING OF ACCIDENTS

A In case of any injury, the Contractor shall send the injured person to First Aid Center where

the injured shall be given the first aid treatment and the injured quantum of permanent

disablement / temporary disablement shall be assessed to ensure payment for compensation

to be paid, by the Contractor to the victim.

B In case the subsequent treatment given to other than PVUNL Hospitals, the Contractor shall

submit the full information about the treatment of injured person including the address etc.

till the person is certified fit by any Govt. / PVUNL doctor. He shall submit such record to

PVUNL safety department within 15 calendar days of certified fit by the Doctor as above.

C The Contractor shall report immediately about the serious injury / fatality in his work area to

the local police station, Dist. Magistrate, Safety Officer in-Charge and Engineer In-Charge

Page 123: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

126

on the prescribed format. In case of near miss accidents minor injury, he shall report the same

Safety Officer in-charge and Engineer In-charge immediately after referring the injured to

PVUNL Plant Hospital / Dispensary/ First Air Center.

D Whenever asked by PVUNL, the Contractor shall send his employees to dispose in any

enquiry arising out of any injury / fatality / loss etc. without any reservation.

23 PERSONNEL PROTECTIVE EQUIPMENT

A The Contractor shall provide safety helmets to all his employees including Contractor labour

of his sub-contractor of his sub-contractor to prevent a danger of falling object. Whenever any

worker is engaged on a work at a place from which he is liable to fall more two matters shall

with safety Harness equipment with lifelines which are secured to a fixed structure. A

competent person to ensure that no belt or lifeline that is not a good condition is used shall

examine all safety belts and lifelines at frequent interval.

B Whenever the workers are exposed more than to the noise levels specified in the concerned

State Factory Rules, be provided with suitable ear plugs / ear muffs so as to reduce the

exposure below high noise level.

C Personal protective Equipment as prescribed in the Factory Act / or State Factories Rules,

the Contractor shall provide to the workers. In case the Factories Act / State Factories Rules

do not specify the personal protective equipment for the concerned work, the Contractor

shall provide the personal protective equipment prescribed by PVUNL Engineer In-charge.

The quality of the personal protective equipment shall be as prescribed in concerning Indian

Standards. In case, the Indian Standards do not exist for particular personal protective

equipment, International standard Marked shall be procured It will be the responsibility to

ensure that all his employees use these equipment without fail.

24 PENALITIES

A If the contractor falls in providing safer working environment as prescribed in General

Condition of Contract relating to safety and health of continue the work even after being

instructed to stop the work by Engineer in-Charge, the Contractor shall be penalized @ Rs.

5,000/- per day or part thereof till the instructions are complied with and so certified by the

Engineer in-Charge. However, in case of accident causing major injury or fatal, the

provisions contained below shall also apply in addition to the penalties mentioned in this cause.

B If the Contractor does not take all safety precautions and / or fails to comply with the Safety

Rules as prescribed by the Employer or under the applicable law for the safety of the plant

and equipment and for safety of personal and the Contractor does not prevent hazardous

conditions which cause injury to this own employees or employees of the other Contractors, or

the Employers employees or any other person who are at site or adjacent thereto, the

Contractor shall be responsible for payment of penalty to PVUNL as per the following

schedule : -

i. For fatal accident / injury causing death Penalty @ 10% of the contract value or

Rs. 5 lakh whichever is less for each fatal

Accident / injury causing death

ii. Major injury or accident causing 25% or more permanent disablement to

workmen

Penalty @ 2.5% of the contract value or Rs.

1 lakh whichever is less for each

disablement injury.

C Permanent disablement shall have the same meaning as indicated in Workmen's

Compensation Act, 1923. The penalty mentioned above shall be in addition to the

compensation payable to the workmen / employees under the relevant provisions of the

Workmen's Compensation Act and Rules framed there under or any other applicable laws as

applicable from time to time.

D If any Contractor worker found working without using the safety equipment like safety

helmet, safety shoes, safety belts etc. or without anchoring the safety belts while working at

height the Engineer in-Charge / Safety Officer of PVUNL, Shall have the right to penalize

the Contractor for Rs.200/- per person per day and such worker shall be sent out of the

workplace immediately and shall not be allowed to work on that day Engineer in-Charge /

Safety Officer of PVUNL will also issue a notice in this regard to the Contractor.

Page 124: BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR · BID DOCUMENT AND SPECIAL TERMS & CONDITIONS FOR SALE OF DECOMMISSIONED PATRATU THERMAL POWER PLANT, PATARTU OF ... Pre-Bid EMD Rs.8,00,00,000/-

127

PHOTOGRAPHS

(Please see annexure-II)