big dutchman stallklima poultry pig climate control wall fans en

6
Wall fans High air performance and low energy consumption

Upload: nenad-jovanovski

Post on 22-Oct-2015

98 views

Category:

Documents


2 download

DESCRIPTION

Big Dutchman Stallklima Poultry Pig Climate Control Wall Fans En

TRANSCRIPT

Page 1: Big Dutchman Stallklima Poultry Pig Climate Control Wall Fans En

Wall fansHigh air performance and low energy consumption

Page 2: Big Dutchman Stallklima Poultry Pig Climate Control Wall Fans En

Wall fans – efficient and durableThe Big Dutchman wall fans are very versatile with a high performance, low energy consumption and low maintenance costs. They are also corrosion-proof and

made for a long service life. Thanks to the large variety they can be ideally adapted to any type of barn. In addition to steel-frame axial fans, we also offer V-belt

driven fans.Let our experts advise you which solution best fits your requirements.

Axial fans with frameExcellent adjustability

Our axial fans with frame are ideally suited for incorporation into walls. The frame has an aerodynamic shape and is made of high-quality sheet steel. The blades are made of moulded aluminium diecasting and therefore have an exceptionally high degree of efficiency. Our product range includes standard fans (FC) as well as sickle-shaped fans (FE), the latter being more pressure-resistant and quieter.

Advantages4 excellent adjustability;

4 high air capacity at a low energy consumption;

4 low noise level;

4 quick and easy assembly;

4 high corrosion resistance;

4 long service life.

ShuttersThis shutter is a self-actuated closing flap made of PVC. If the fan is at a standstill, the shutter is closed.

Wire mesh guardA wire mesh guard is required if the fan is installed in an accessible location.

Standard fan (FC) Sickle-shaped fan (FE)

Ø Impeller A B C D E F (in cm) (in mm) 35 435 485 375 86 75 89 40 490 540 420 91 88 102 45 535 575 480 75 96 123 50 615 655 528 77 104 141 56 675 725 589 60 119 138 63 750 805 664 64 130 154 71 810 850 763 44 150 202 80 910 970 869 34 193 252 91 1010 1070 977 48 190 197

Dimensions and installation details

Page 3: Big Dutchman Stallklima Poultry Pig Climate Control Wall Fans En

Advantages4 optimised aerodynamics at the air admission and air exit sides for a high air flow rate;4 specially-formed blades ensure optimum operation thus reducing energy costs;4 the shutters open by the air flow pressure and stay open thanks to

balancing weights –> minimal air resistance;4 low noise level;4 stable, robust and simple design;4 easy to assemble and easy to install in the building.

Important componentsCasingThe fan casing consists of galvanized sheet steel, the inside construction is made of high-quality polypropylene for a high corrosion resistance.

Blade and blade hubThe vane has 3 or 5 specially shaped blades made of glass-fibre reinforced plastic. Air guide-rails on every blade ensure a large air capacity combined with a low resistance and thus low energy consumption. The blade hub is made of aluminium.

The 5-blade AirMaster is often installed in barns with a high back pressure (cage houses with tunnel ventilation, use of exhaust air treatment systems).

ShuttersThe shutters are opened by the air flow and then kept open by means of a balancing weight. When the fan stops, the shutters close.

V-belt gearingThe V-belt pulley is made of aluminium and is manufactured as one piece together with the blade hub by diecasting.

The V-belt is pretensioned, further tensioning is therefore not necessary.

Electric motorsWe use high-quality motors with a large voltage range (motor protection IP 55, approved for UL/CSA). The motor is completely closed; a separate cooling fan is not necessary. This means there is no danger of dust entering the motor or overheating of the motor.

AirMasterHigh air performance

specially-formed blades made of glass-fibre reinforced plastic with air guide-rails for optimum air performance

central V-belt pulley made of aluminium with pretensioned V-belt–> retensioning not necessary

extremely stable connection between hub and blade–> copes well with high loads

electric motor without cooling fan with protective cover–> well-protected against dust

diagonal braces for better stability

fan with 3 or 5 blades

all 4 corners are equipped with plastic covers–> no dirt corners–> good hygiene

shutters are opened by the air flow–> a centrifugal system is not necessary

Page 4: Big Dutchman Stallklima Poultry Pig Climate Control Wall Fans En

0831

225

572

58

25159

1380

287

5721

0831331

0061Ø

572

1380

58

Light trapAirMaster with coneBig Dutchman offers two light traps. The previous model reduces the amount of light passing through the fan to a minimum and is thus especially suited for rearing and breeding houses. The air performance is reduced by approx. 12 %.

The new light trap PerforMacs is ideally suited for broiler and laying houses. It has been optimised aerodynamically, reducing the air performance by only approx. 10 %.The segments of both light traps are made of plastic which makes them extremely durable and easy to clean.

Cone fans (VC130) are mainly used in barns with especially large air-flow performance requirements. They are also characterized by a low power consumption.

Technical specifications of the series AirMaster V130/VC130Type Code No. Speed Air capacity in m3/h Consumption Spec. output Noise level control 0 Pa 20 Pa 30 Pa 40 Pa 60 Pa 80 Pa Ampere Watt/1000m3/h dB(A)*

V130-3 1.0 PS E13 60-25-4509 NC 40400 36100 33100 29900 2.2 27.5 72V130-3 1.5 PS E13 60-25-4501 NC 44700 40500 38400 36000 29300 3.0 33.6 74V130-3 1.5 PS E13 60-25-4503 FC 44700 40500 38400 36000 29300 3.0 33.6 74V130-5 1.5 PS E13 60-25-4505 NC 39600 36500 35000 33400 29800 25600 3.0 34.3 74V130-5 1.5 PS E13 60-25-4507 FC 39600 36500 35000 33400 29800 25600 3.0 34.3 74V130-3 1.5 PS-R 60-25-4141 FC 43700 39700 37500 34800 28600 19200 3.1 36.7 74V130-5 1.5 PS-R 60-25-4140 FC 38700 35600 34100 32500 28800 24500 3.0 36.8 74VC130-3 1.0 PS E13 60-25-4565 NC 44500 40400 37800 35400 2.3 24.6 72VC130-3 1.5 PS E13 60-25-4561 NC 49000 45200 43100 40700 35900 3.0 29.9 74VC130-5 1.5 PS E13 60-25-4563 NC 43100 40000 38700 37000 33900 28300 3.0 29.8 74VC130-3 1.5 PS-R 60-25-4020 FC 47700 43800 41600 39200 34300 21800 3.2 34.3 74VC130-5 1.5 PS-R 60-25-4060 FC 41800 38800 37200 35600 32300 27100 3.1 33.4 74

V = fan without cone; VC = fan with cone; 130 = diameter of impeller; 3 = 3-blade; 5 = 5-blade; R = standard motor (only for use outside of the EU) E13 = complies with the directive 2009/125/EC (ErP Directive) starting 2013NC = non-controllable FC = frequency-controllableConnection values: 400 V, 50 Hz; on request available with other voltages and frequenciesWeight: AirMaster without cone: 80 kg; AirMaster with cone: 99 kg* Noise level measured at the outlet side 45° lateral, at a distance of approx. 2 m; all types also available unassembled

Dimensions: V130 VC130If used in the EU, the fans must carry the CE mark of conformity. As opposed to fans without CE mark these fans possess a protective grating (in front of the shutters at an installation height below 2.70 m).

Page 5: Big Dutchman Stallklima Poultry Pig Climate Control Wall Fans En

Technical specifications of axial fans with frame

Technical specifications: 1 ~ 230 V, 50 Hz

Technical specifications: 3 ~ 400 V, 50 Hz

The noise level was measured free-blowing at a 45° angle from the centre of the fan at a distance of 7 m (at 0 Pa pressure increase).

The capacity was measured without wire mesh guard and at an air density of 1.2 kg/m3.

The capacity was measured without wire mesh guard and at an air density of 1.2 kg/m3.

The noise level was measured free-blowing at a 45° angle from the centre of the fan at a distance of 7 m (at 0 Pa pressure increase).

Single-phase power supply 230 V, 50 Hz: capacity (m3/h) / spec. output (W/1000 m3/h)Type / Negative pressure 0 Pa 10 Pa 20 Pa 30 Pa 40 Pa 50 PaFC035-4EQ 3460 / 45.4 3320 / 47.9 3180 / 50.9 3050 / 53.8 2910 / 57.0 2810 / 59.4FC040-4EQ 4790 / 48.2 4510 / 52.1 4240 / 56.6 3950 / 61.5 3640 / 67.3 3260 / 75.2FC045-4EQ 6350 / 53.7 6260 / 55.9 6120 / 58.0 5950 / 61.2 5780 / 64.9 5560 / 68.3FC050-4EQ 8000 / 55.4 7800 / 58.1 7660 / 61.0 7400 / 64.6 7250 / 67.7 6900 / 73.0FC056-6EQ 8870 / 43.7 8560 / 46.0 8210 / 49.0 7860 / 51.7 7430 / 55.3 6910 / 60.3FC063-6EQ 12300 / 42.3 11750 / 45.3 11400 / 47.6 11000 / 50.0 10550 / 53.0 10000 / 56.8FC071-6EQ 16450 / 47.6 15950 / 50.4 15550 / 52.7 15000 / 55.6 14600 / 58.2 14000 / 61.2FC080-6EQ 23000 / 50.4 22300 / 53.4 21700 / 56.0 21050 / 58.7 20450 / 61.4 19850 / 64.3FE091-6EQ 23130 / 38.7 22200 / 41.3 21200 / 44.1 20100 / 46.9 18600 / 50.8 17600 / 54.0

Three-phase power supply 400 V, 50 Hz: capacity (m3/h) / spec. output (W/1000 m3/h)Type / Negative pressure 0 Pa 10 Pa 20 Pa 30 Pa 40 Pa 50 PaFC045-4DQ 6470 / 45.6 6290 / 48.0 6130 / 50.4 5950 / 52.9 5820 / 55.3 5650 / 58.1FC050-4DQ 8330 / 51.1 8120 / 53.8 7970 / 56.3 7800 / 59.6 7630 / 62.1 7470 / 64.3FC056-6DQ 8850 / 36.5 8530 / 38.7 8200 / 41.3 7850 / 44.5 7480 / 47.3 7060 / 50.7FC063-6DQ 12750 / 38.0 12380 / 40.4 12000 / 43.0 11650 / 45.5 11190 / 48.7 10760 / 51.3FC071-6DQ 17000 / 45.9 16600 / 48.2 16150 / 50.5 15600 / 53.1 15300 / 54.8 14800 / 57.6FC080-6DQ 22900 / 48.9 22440 / 51.3 21920 / 53.6 21400 / 56.4 20900 / 58.9 20340 / 61.5FE091-6DQ 23370 / 36.5 22400 / 34.4 21410 / 41.4 20450 / 44.0 19450 / 46.7 18410 / 49.7

The motors are fabricated according to the IP 54 (dust-proof and water-proof) protection system. All mentioned fans 1 ~ 230 V and 3 ~ 400 V can be controlled electronically or by a transformer. On request the fans are also available frequency-controlled and/or with different supply voltage and/or 60 Hz.

Air capacity

Description detailsFC035-4EQ FC = standard fan 4 = 4-pole; 6 = 6-pole E = 1-phase (1~ 230 V)FE091-6DQ FE = sickle-shaped fan 35 = dia impeller (cm) D = 3-phase (3~ 400 V) Q = wall installation

FC035-4EQ FC040-4EQ FC045-4EQ FC050-4EQ FC056-6EQ FC063-6EQ FC071-6EQ FC080-6EQ FE091-6EQCode No. 60-47-9135 60-47-9140 60-47-9145 60-47-9150 60-47-9156 60-47-9163 60-47-9171 60-47-9180 60-47-9191Power consumption (Watt) 157 243 341 450 388 545 785 1.160 895Nominal current (Ampere) 0.75 1.3 1.9 2.3 1.95 2.7 4.1 6.3 4.6Motor protection switch (Ampere) 1.0 1.4 2.3 2.7 2.2 3.0 4.6 6.7 5.2Noise level (dB(A)) 46 51 53 54 48 53 55 55 57

FC045-4DQ FC050-4DQ FC056-6DQ FC063-6DQ FC071-6DQ FC080-6DQ FE091-6DQCode No. 60-47-9645 60-47-9650 60-47-9656 60-47-9663 60-47-9671 60-47-9680 60-47-9691Power consumption (Watt) 295 432 323 484 780 1120 939Nominal current (Ampere) 0.8 1.1 0.74 1.4 1.8 2.7 1.95Motor protection switch (Ampere) 0.9 1.3 0.8 1.5 1.9 3.1 2.4Noise level (dB(A)) 53 54 48 53 55 55 57

Page 6: Big Dutchman Stallklima Poultry Pig Climate Control Wall Fans En

Abb. 762

Tech

nica

l det

ails

sub

ject

to c

hang

e. e

n 6/

2013

USA: Big Dutchman, Inc.Tel. +1 616 392 5981 · [email protected]: Big Dutchman (Brasil) Ltda.Tel. +55 16 2108 5300 · [email protected] www.bigdutchman.com.brRussia: OOO “Big Dutchman”Tel. +7 495 2295 171 · [email protected] · www.bigdutchman.ruAsia/Pacific: BD Agriculture (Malaysia) Sdn. Bhd.Tel. +60 3 33 61 5555 · [email protected] · www.bigdutchman.comBD Agriculture (Thailand) Ltd.Tel. +66 2 349 6531 · [email protected] · www.bigdutchman.co.thChina: Big Dutchman (Tianjin) Livestock Equipment Co., Ltd.Tel. +86 10 6476 1888 · [email protected]

Germany: Big Dutchman International GmbHBig Dutchman Pig Equipment GmbHPostfach 1163 · 49360 VechtaTel. +49(0)4447 801-0 · Fax [email protected] · www.bigdutchman.de

Areas of applicationOur wall fans are very versatile. Depen ding on the climate zone, different ventilation concepts are possible.Side and cross ventilation are often established by means of axial fans. They pull the air across the barn. Longitudinal ventilation is normally accomplished by means of AirMaster fans as these have a higher air capacity.

In case of tunnel ventilation they pull the air through the barn in longitudinal direction at a high air speed. This is a so-called displacement ventilation at minimum energy consumption. CombiTunnel ventilation is best installed in climate zones with large temperature fluctuations – summer/winter or day/night temperatures.

In the case of decentralized exhaust air extraction via chimneys in the roof, AirMaster fans in the gable can be switched on for additional ventilation on hot summer days.

Cross ventilationSide ventilation

Longitudinal ventilation Tunnel ventilation

CombiTunnel ventilation Decentralized exhaust air extraction with additional gable ventilation