bill no 4, samad hanger

194
PACKAGE - 01 BILL NO - 4 SAMAD HANGER

Upload: karikaalan-soundararajan

Post on 28-Oct-2015

35 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Bill No 4, Samad Hanger

PACKAGE - 01

BILL NO - 4

SAMAD HANGER

Page 2: Bill No 4, Samad Hanger

.

1142.04.2012 4.14/2

commercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Summary

ITEM

DESCRIPTIONAMOUNT

NO. R.O

BILL NO. 4

HANGER

SUMMARY

PK1/4/Section 1 - Foundation including Ground floor slab From Page - 4.1/7

PK1/4/Section 2 - Concrete Work From Page - 4.2/7

PK1/4/Section 3 - Masonry From Page - 4.3/4

PK1/4/Section 4 - Metal Work From Page - 4.4/14

PK1/4/Section 5 - Roofing From Page - 4.5/5

PK1/4/Section 6- Door & Frames From Page - 4.6/3

PK1/4/Section 7- Carpentry & Joinery From Page - 4.7/4

PK1/4/Section 8 - Finishes From Page - 4.8/9

PK1/4/Section 9- Painting & Decoration From Page - 4.9/1

PK1/4/Section 10- Ironmongery From Page - 4.10/3

PK1/4/Section 11- Equipments From Page - 4.11/1

PK1/4/Section 12- Mechanical Engineering Installation

Plumbing & Fire fighting From Page - 4.12/18

HVAC Installation From Page - 4.12/43

PK1/4/Section 13- Electrical Engineering Installation From Page - 4.13/55

Page 3: Bill No 4, Samad Hanger

.

1142.04.2012 4.14/3

commercial in confidential

Summary of Bill No. 4 Carried to Grand Summary

Page 4: Bill No 4, Samad Hanger

1142.04.20124.1/4

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Foundation Incl. GF Slab 4.1

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

SITE WORKS

Site works measured under Bill No10. Note

EXCAVATION

A Excavation for pit foundation 3000 m3

B Excavation fro trench/ strip 375 m2

Disposal

C3375 m3

DItem

Filling

F

2125 m3

To Collection R.O.

FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL)

Load and remove surplus excavated material from site including providing suitable tip as specified

Allow for removal of mud accumulations from site including providing suitable tip as specified

200mm Thick well graded natural macadam base, properly levelled and compacted to 100% modified protector and CBR 30 under slab on grade

Page 5: Bill No 4, Samad Hanger

1142.04.20124.1/5

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Foundation Incl. GF Slab 4.1

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

EXCAVATION (Cont'd)

Anti-termite treatment as specified

A

Item

CONCRETE WORK

B Blinding 100mm thick 1155 m2

C Isolated footings 540 m3

D Strip footings 15 m3

E Column shafts 11 m3

F Tie beams 42 m3

G Plinth beams 71 m3

H Allow for ramps Item

J 150mm Thick slab on grade 204 m3

K Base and walls of ditch channel 88 m3

L 300mm Thick slab on grade 1542 m3

To Collection R.O.

FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) Cont'd

Anti-termite treatment to soil under building, applied strictly in accordance with the manufacturer's printed instructions including the provision for producing 10year guarantee (Approx. area 7161m2)

Plain poured OPC concrete cube strength 220kg/cm as specified

Reinforced poured vibrated OPC concrete grade M35 as specified

Poured vibrated special designed fibres concrete C25/30 OPC reinforced with 30kg/m3 of steel fibres with 60mm long and 0.75mm diameter

Page 6: Bill No 4, Samad Hanger

1142.04.20124.1/6

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Foundation Incl. GF Slab 4.1

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

REINFORCEMENT

A Isolated footings 81000 kg

B Strip footings 1500 kg

C Column shafts 2200 kg

D Tie beams 5040 kg

E Plinth beams 8520 kg

F Allow for ramps Item

G Ditch channel 1553 kg

H Single layer BRC mesh ref. A-142 1360 m2

J Single layer BRC mesh ref. A-393 (ditch channel) 668 m2

To Collection R.O.

FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) Cont'd

High yield deformed steel bar reinforcement, characteristic yield strength of steel - 460n/mm2 as specified

Page 7: Bill No 4, Samad Hanger

1142.04.20124.1/7

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Foundation Incl. GF Slab 4.1

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

Formwork to give 'as struck' finish

A Sides of, column footings 661 m2

B Ditto, strip footings 51 m2

C Sides of, column shafts 409 m2

D Ditto, tie beams 239 m2

E Ditto, plinth beams 578 m2

F Edge of ramps Item

G Sides of walls & base of ditch channel 426 m2

Miscellaneous works

H

Item

To Collection R.O.

FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) (Cont'd)

Allow for construction of floating floor arrangement for machine plinths complete with 50mm thick Neoprene mounts, corrugated galvanized sheet, concrete works, reinforcements, isolation boards, sealant etc. as shown on drawing 2037/00/AC-1000 and specifications

Page 8: Bill No 4, Samad Hanger

1142.04.20124.1/8

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Foundation Incl. GF Slab 4.1

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

SUNDRIES

A

5140 m2

BItem

C

Item

Isolation Joints

D 500mm High isolation joint 203 m

E 150mm, Ditto 492 m

Expansion Joints

F

11 m2

To Collection R.O.

FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) (Cont'd)

Monolithic surface hardener (Dry-shakes) applied on concrete floor (measured separately) made with quartz mineral aggregates in classical gray colour

Forming 100mm deep retraction joints in concrete floor bed

Forming construction joint in hanger floor bed with steel divider plate, plastic dowel sleeve, asphalt dowel, 10 x 10mm shear anchorage and 10mm wide cold-drain square edge steel top strip

Forming 20mm wide isolation joint in floor bed filled with ethylene polymer layer as specified

Forming 25mm thick expansion joint in floor slab and beams complete with compressible filler and ends covered with sealant

Page 9: Bill No 4, Samad Hanger

1142.04.20124.1/9

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Foundation Incl. GF Slab 4.1

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

SUNDRIES (Cont'd)

Waterproofing

A

8547 m2

B

2931 m2

To Collection R.O.

FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) (Cont'd)

1000 Gauge plastic damp proof membrane (under slab on grade, column footings, tie beams and plinth beams etc..)

Prepare and apply one coat of bituminous protective coating and two coat of high build bituminous protective compound, apply to concrete surfaces below ground level

Page 10: Bill No 4, Samad Hanger

1142.04.20124.1/10

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Foundation Incl. GF Slab 4.1

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

COLLECTION

4.1/1

4.1/2

4.1/3

4.1/4

4.1/5

4.1/6

Carried to Summary of Bill No. 4.1 R.O.

FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL)

Page 11: Bill No 4, Samad Hanger

1142.04.2012 4.2/11Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Concrete Works 4.2

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

CONCRETE WORK

Reinforced poured vibrated OPC concrete grade M35

A Columns 39 m3

B Beams 108 m3

C Suspended slabs 120mm thick 4 m3

D Ditto, 140mm thick 11 m3

E Ditto, 160mm thick 27 m3

F Ditto, 200mm thick 81 m3

G Lintels 11 m3

H Extra over for forming recess arches in lintels. Item

J Staircases & landings 15 m3

K Walls 2 m3

L Steps Item

M 350 x 150mm coping 11 m3

Page 12: Bill No 4, Samad Hanger

1142.04.2012 4.2/12Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Concrete Works 4.2

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

CONCRETE WORK (Cont'd)

REINFORCEMENT

A Columns 7800.00 kg

B Beams 13500.00 kg

C Suspended slabs 13530.00 kg

D Lintels 825.00 kg

E Staircases 1875.00 kg

F Walls 220.00 kg

G Steps Item

H 350 x 150mm coping 782.00 kg

High yield deformed steel bar reinforcement, characteristic yield strength of steel - 460N/mm2 as specified

Page 13: Bill No 4, Samad Hanger

1142.04.2012 4.2/13Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Concrete Works 4.2

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

CONCRETE WORK (Cont'd)

Formwork to give 'stuck' finish

A Sides of columns 451 m2

B Sides and soffit of beams 633 m2

C Sides and soffit of lintel 107 m2

D 160mm high step riser 84 m

E Sides of walls 23 m2

F 140mm Wide edge of slab 40 m

G 160mm Ditto, 118 m

H 200mm Ditto, 89 m

J Allow for steps Item

K Sides of coping 64 m2

Formwork to give 'fair face' finish

L Soffit of suspended slab / landings 694 m2

M Sloping sides of staircase 16 m2

N Sloping soffit of staircase 37 m2

Page 14: Bill No 4, Samad Hanger

1142.04.2012 4.2/14Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Concrete Works 4.2

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

CONCRETE WORK (Cont'd)

Pre-cast Concrete

A 900mm Long 22 No

B 1200mm, Ditto 8 No

C 3000mm, Ditto 3 No

D 5000mm, Ditto 2 No

Precast Concrete cornice

E

21 m

Composite Floor Slab

F 135mm Composite metal deck 1,233 m2

200mm high Fare face concrete sills including forming drip edge as detail in drawings

Pre-cast concrete decorative cornice fixed to concrete or block walls, 750mm wide including decorative paint finish and fixing accessories as specified at 5.8m level

Composite floor slab complete with corrugated metal deck, concreting, single layer of A393 mesh reinforcements, shear studs etc. to complete construction as drawings and specifications

Page 15: Bill No 4, Samad Hanger

1142.04.2012 4.2/15Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Concrete Works 4.2

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

CONCRETE WORK (Cont'd)

MISCELLANEOUS WORKS

A

Item

B

Item

C Allow for RC copings 350 x 150mm thick 213 m

Allow for 200mm thick mullions complete with concrete, reinforcements, formworks etc. for 200mm thick block walls when panel exceeds either 5m in length or 4m in height, laid horizontally and vertically

Allow for 350mm thick mullions complete with concrete, reinforcements, formworks etc. for 350mm thick block walls when panel exceeds either 6m in length or 5m in height, laid horizontally and vertically

Page 16: Bill No 4, Samad Hanger

1142.04.2012 4.2/16Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Concrete Works 4.2

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

CONCRETE WORK (Cont'd)

SUNDRIES

A Allow for construction joint complete as specified Item

B 15 m2

CItem

Allow for 20mm thick expansion joint, complete as specified

Allow for providing ties between concrete columns/walls and block work

Page 17: Bill No 4, Samad Hanger

1142.04.2012 4.2/17Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Concrete Works 4.2

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

COLLECTION

4.2/1

4.2/2

4.2/3

4.2/4

4.2/5

4.2/6

Page 18: Bill No 4, Samad Hanger

1142.04.2012 4.2/18Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Concrete Works 4.2

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

CONCRETE WORK Carried to Summary of Bill No. 4 R.O.

Page 19: Bill No 4, Samad Hanger

1142.04.2012 4.3/19Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Masonry 4.3

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

MASONRY

Note:

BLOCKWORK

A 100mm Walls 91 m2

B 200mm Walls 1,194 m2

C 190mm Skin of cavity walls 2,167 m2

D 90mm Skin of cavity walls 2,167 m2

E 200mm Parapet wall with decorative turret 130 m2

F Overall size 1500 x 3300mm 2 No.

G Ditto, 4350 x 5300mm 1 No.

1. Block work rates are to include forming recess panels, working on projections and the like, if these items are not specifically measured

2. The rates for block work are to include reinforcement and concrete filling adjacent to door, window and other openings, between concrete and block work and inter sections as described in the specifications

3. Rates are to include for providing galvanized wall ties between wall panels at cavity walls, as specified

Precast Ordinary Portland Cement solid non-load

bearing block work in cement sand mortar as specified

Extra over for forming of arches as Drg No. 002/MU/04/(A31)02

Page 20: Bill No 4, Samad Hanger

1142.04.2012 4.3/20Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Masonry 4.3

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

MASONRY (Cont'd)

BLOCKWORK (Cont'd)

A Overall size 900 x 1950mm 20 No

B Overall size 5000 x 1950mm 2 No

SUNDRIES

C 60mm Cavity 2,167 m2

D 50mm Thick insulation 2,167 m2

Wall end

E For 340mm cavity walls 487 m

F For 200mm thick walls 250 m

Extra over for forming of arched recess as elevation D, Drg No. 002/MU/04/AR- 04

Forming cavity between block work skins of cavity wall

Rigid extruded polystyrene thermal insulation (XPS) board pinned vertically against block work including cutting and fitting around wall ties, all as specified

Galvanized mild steel butterfly pattern wall ties one end cast into concrete and other end built into joint of block walls as specified

Page 21: Bill No 4, Samad Hanger

1142.04.2012 4.3/21Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Masonry 4.3

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

MASONRY (Cont'd)

SUNDRIES (Cont'd)

Wall head

A For 340mm cavity walls 395 m

B For 200mm thick walls 190 m

C For 100mm thick walls 25 m

Allow for 12mm thick compressible filler board set between top of block work and soffits of reinforced concrete structure

Page 22: Bill No 4, Samad Hanger

1142.04.2012 4.3/22Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Masonry 4.3

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

COLLECTION

4.3/1

4.3/2

4.3/3

Page 23: Bill No 4, Samad Hanger

1142.04.2012 4.3/23Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Masonry 4.3

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

MASONRY Carried to Summary of Bill No. 4 R.O.

Page 24: Bill No 4, Samad Hanger

1142.04.2012 4.4/24Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

METAL WORKS

STRUCTURAL METAL WORKS

Design

Item

Columns

A Column, Ref C1, size 914 x 305 x 289 UB 159,155 Kg

B Ditto, Ref C2, size 610 x 305 x 149 UB 46,818 Kg

C Ditto, Ref C3, size 305 x 305 x 198 UC 7,840 Kg

D Ditto, Ref C4, size 457 x 191 x 133 UB 9,815 Kg

E Ditto, Ref C5, size 300 x 90 PFA 1,541 Kg

F Ditto, Ref C6, size 203 x 203 x 60 UC 492 Kg

Allow for design, design development, preparation of workshop drawings & method statements and design co-ordination with other building elements

Bolted and welded work; structural columns as shown on drawings and described in the specification including shot blast, protective & decorative paint finish

Page 25: Bill No 4, Samad Hanger

1142.04.2012 4.4/25Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

METAL WORKS

STRUCTURAL METAL WORKS (Cont'd)

Roof Beams

A Beam, Ref. B1, size 914 x 305 x 253 kg/m 230,642 Kg

B Ditto, Ref. B2, size 273 x 125 CHS 1,848 Kg

C Ditto, Ref. B3, size 610 x 229 x 101kg/m 25,395 Kg

D Ditto, Ref. B4, size 610 x 229 x 125kg/m 1,877 Kg

E Ditto, Ref. B5, size 406 x 178 x 74kg/m 3,908 Kg

F Ditto, Ref. B6, size 457 x 191 x 89kg/m 1,100 Kg

G Ditto, Ref. B8, size 406 x 178 x 60kg/m 10,935 Kg

H Ditto, Ref. B10, size 356 x 191 x 57kg/m 2,659 Kg

J Ditto, Ref. B11, size 254 x 146 x 37kg/m 3,748 Kg

Bracings

K Vertical bracings, size 219 x 12.5 CHS 39 m

L Ditto, size 219 x 10.0 CHS 208 m

M Horizontal bracings, size 219 x 8.0 CHS 366 m

Bolted and welded work; structural members as shown on drawings and described in the specification including gusset plates, bolts & nuts etc. shot blast, protective & decorative paint finish

Page 26: Bill No 4, Samad Hanger

1142.04.2012 4.4/26Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

METAL WORKS

STRUCTURAL METAL WORKS (Cont'd)

Door Support Truss

A Beam, Ref. B1, size 406 x 178 x 60 kg/m 10,578 Kg

B Ditto, Ref. B2, size 254 x 146 x 34 Kg/m 1,320 Kg

C Ditto, Ref. B4, size 254 x 146 x 37 Kg/m 20,108 Kg

D Ditto, Ref. B5, size 305 x 165 x 54 Kg/m 2,096 Kg

E Ditto, Ref. B6, size 219 x 8 CHS 44 m

F Ditto, Ref. B6, size 219 x 10 CHS 163 m

Crane Beams

G Crane beam, size 610 x 229 UB 125 with 300 x 90 PFC 24,632 Kg

H Ditto, 356 x 71 UB57 11,233 Kg

J 8 No

K 8 No

Bolted and welded work; structural members as shown on drawings and described in the specification including gusset plates, cleats, bolts & nuts etc. shot blast, protective & decorative paint finish (Cont'd)

254 x 254 UC73 Stub, 300mm long, welded to top of crane beam

406 x 176 UB74 Bracket, overall size 350 x 406mm welded to face of column

Page 27: Bill No 4, Samad Hanger

1142.04.2012 4.4/27Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

METAL WORKS

STRUCTURAL METAL WORKS (Cont'd)

Side rails

A Metsec sleeved side rail, size 202 Z 20 1,306 m

Purling

B 202 Z 20 sleeved steel purling 4,608 m

Rafter stays

C RSA Rafter stays in suitable size, 940mm long 2,592 No

Base plates

D Base plates, size 1100 x 500 x 50mm 29 No

E Ditto, size 800 x 500 x 35mm 16 No

F Ditto, size 500 x 500 x 35mm 9 No

G Ditto, size 650 x 400 x 20mm 4 No

H Ditto, size 400 x 250 x 15mm 8 No

J Ditto, size 300 x 300 x 20mm 1 No

Bolted and welded work; structural members as shown on drawings and described in the specification including gusset plates, cleats, bolts & nuts etc. shot blast, protective & decorative paint finish (Cont'd)

Page 28: Bill No 4, Samad Hanger

1142.04.2012 4.4/28Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

METAL WORKS

STRUCTURAL METAL WORKS (Cont'd)

Washer plates

A Washer plate, size 1100 x 150 x 10mm thick 58 No

B Ditto, size 800 x 150 x 10mm thick 32 No

C Ditto, size 500 x 150 x 10mm thick 26 No

D Ditto, size 400 x 150 x 10mm thick 18 No

Anchor Bolts & Nuts

E M32 Resin anchors, 350mm long 596 No

F M24 Resin anchors, 350mm long 90 No

Grouting

G 67 No

Fittings and fixings as shown on drawings and described in the specifications

Allow for high strength non-shrink grout filling under base plates

Page 29: Bill No 4, Samad Hanger

1142.04.2012 4.4/29Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

METAL WORKS

STRUCTURAL METAL WORKS (Cont'd)

Scaffolding

A Allow for all necessary access scaffolding; owned/hired Item

SundriesB

Allow for Third Party inspection of steel / welding Item

C Other Items

Contractor shall list here other items not included above but necessary for the complete and satisfactory completion of this section of the works. Such items shall be deemed to be included unless specifically listed here.

Page 30: Bill No 4, Samad Hanger

1142.04.2012 4.4/30Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

METAL WORKS

NON STRUCTURAL METAL WORKS

Wall Cladding

A

4,250 m2

B

Item

C

Item

D Drip flashing with minimum 150mm sealed lap joint 213 m

Walk way

E Walkway, 50m long, 1.2m wide at +12.4m level 4 No

218mm thick twin skin insulated wall cladding system complete with frame work and all accessories shown on drawing 002/MU/04/AR-09 and as specified.

Allow for insulated per-coated sandwich panel cladding, fixed to external walls as specified on room data sheet, at 1st floor level rooms around F01, F02 & F03 (Approx. area 532m2)

Allow for internal lining of insulated wall cladding system, fixed to walls above 3m from FFL as specified on room data sheet, at 1st floor level rooms around F01, F02 & F03 (Approx. area 249m2)

Walk way with 1000mm high steel handrail complete with structural framework, floor boards including necessary welding, bolts and nuts, protective and decorative paint finishes as specified

Page 31: Bill No 4, Samad Hanger

1142.04.2012 4.4/31Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

Balustrades and Handrails

F For staircase, ST-01 10 m

To Collection R.O.

METAL WORKS

NON STRUCTURAL METAL WORKS

Balustrades and Handrails (Cont'd)

A For staircases, ST-02, 03 & 04 56 m

Metal Roller Shutters

B 2 No

900mm High balustrades and handrails comprising 65 x 75mm decorative hard wood handrail, 20 x 100mm hard wood horizontal members, 30 x 30mm RHS balustrades, fixed to concrete, all other accessories and decorative paint finishes as detailed on Drg. No. 002/MU/04/AR-11

900mm High balustrades and handrails comprising metal top with plastic handrail cover, horizontal metal rail and vertical steel balusters, fixed to concrete, all other accessories and protective and decorative paint finishes as detailed on Drg. No. 002/MU/04/AR-12 & 13

Heavy duty metal roller shutter complete with 100mm insulated slats, frames, sub frames, fixed to concrete or block walls including power operated / manually operated system and all fixing accessories as specified

Tail Gate: Motorized Roller shutter, overall size 6000 x 4600mm

Page 32: Bill No 4, Samad Hanger

1142.04.2012 4.4/32Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

METAL WORKS

NON STRUCTURAL METAL WORKS

` Sliding doors

A 2 No

B 2 No

Industrial steel double skinned sliding door complete with insulation and 55mm thick door leaf, frames, sub frames, vision panels, tracks, rollers, etc. fixed to concrete or block walls including power operated / manually operated system and all fixing accessories and ironmongery as specified

Sliding door, type SLD-01, overall size 4000 x 5000mm

Sliding door, type SLD-02, overall size 5000 x 5000mm

Hanger door, sliding type bottom railing complete with horizontal side way openings including high performance solar glassing panels, power operated / manually operated systems, finishes to match cladding and all fixing accessories and ironmongery as specified

Page 33: Bill No 4, Samad Hanger

1142.04.2012 4.4/33Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

C 1 No

To Collection R.O.

METAL WORKS

NON STRUCTURAL METAL WORKS (Cont'd)

Aluminium Windows

A 2 No

B 19 No

C 3 No

D 3 No

Overall size 100 x 9m (Including 10 No. each 10 x 9m in size panels)

10mm Thick double glazed tinted panels assembled and installed with white powder coated medium section aluminium channels/frame, ironmongery, external sills, insulation, complete with all fixing as drawing No. 002/MU/04/AR/20 and specifications

Window type FW01, overall size 5000 x 1200mm fixed glass, sound proofed window

Window type W01, overall size 900 x 1200mm sliding, sound proofed window

Window type W02, overall size 900 x 1200mm sliding, sound proofed window

Window type W03, overall size 3000 x 900mm fixed, sound proofed window

Page 34: Bill No 4, Samad Hanger

1142.04.2012 4.4/34Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

E 8 No

To Collection R.O.

METAL WORKS

NON STRUCTURAL METAL WORKS (Cont'd)

Aluminium Doors

A Double leaf door, type D2, overall size 1800 x 2200mm 1 No

B Single leaf door, type D9, overall size 1000 x 2200mm 1 No

Window type W04, overall size 1200 x 1200mm sliding, sound proofed window

Supply and installation of door sets comprising of powder coated aluminium frames, sub frames, architraves, beadings, double glazing panels including ironmongery, specified finishes, pointing around frames in mastic, all ancillary items and final decorations including fixing to concrete or block work as drawings and specifications

Page 35: Bill No 4, Samad Hanger

1142.04.2012 4.4/35Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

C Single leaf door, type D12, overall size 1000 x 2200mm 6 No

D 2 No

E 4 No

F

4 No

To Collection R.O.

METAL WORKS

NON STRUCTURAL METAL WORKS (Cont'd)

Aluminium Doors (Cont'd)

A Single leaf door, type D10, overall size 800 x 2100mm 8 No

Grating

Supply and installation of door sets comprising of powder coated aluminium frames, subframes, architraves, beadings, double skin aluminium external grade door panels including ironmongery specified finishes, pointing around frames in mastic, all ancillary items and final decorations including fixing to concrete or blockwork as drawings and specifications

Double leaf door, type D13, overall size 1600 x 2200mm

Double leaf door, type D13A, overall size 1200 x 2200mm

Single leaf door, type D14, overall size 1000 x 2200mm complete with 700 x 100mm 1 No. view glass (pyrostop 120-106) panel - fire rating FD120S

Supply and installation of door sets comprising of powder coated aluminium frames, subframes, architraves, beadings, double skin construction door panels including ironmongery, specified finishes, pointing around frames in mastic, all ancillary items and final decorations including fixing to concrete or blockwork as drawings and specifications

Page 36: Bill No 4, Samad Hanger

1142.04.2012 4.4/36Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

B Heavy duty grating for ditch channel, 1200mm wide 97 m

Steel Cat Ladder

C steel cat ladder with cage, 12400mm high as specified 4 No

To Collection R.O.

COLLECTION

4.4/1

4.4/2

4.4/3

4.4/4

4.4/5

4.4/6

4.4/7

Page 37: Bill No 4, Samad Hanger

1142.04.2012 4.4/37Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Metal Works 4.4

ITEM DESCRIPTION RATE AMOUNT

NO. QTY. UNIT (R.O.) (R.O)

4.4/8

4.4/9

4.4/10

4.4/11

4.4/12

MASONRY Carried to Summary of Bill No. 4 R.O.

Page 38: Bill No 4, Samad Hanger

1142.04.2012 4.5/38Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Roofing 4.5

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

ROOFING

COVERING AND LINING

A Covering to flat roof laid on screed including priming 1,475 m2

B To skirting and upstand minimum 300mm high 344 m

C 13 No

D Skirting minimum 300mm girth 344 m

E Allow for machine plinths Item

F 50mm Thick covering, laid loose 1,475 m2

G To roof slab 1,475 m2

Reinforced bitumen membrane system to inverted roof covering generally

Roof membrane, flexible, preformed waterproof membrane comprising self- adhesive rubber/bitumen compound bonded to up stand and edges, applied strictly in accordance with manufacturers printed instructions including all necessary additional strips at angle fillets, intersections, etc., complete with mastic pointing all as per drawing No. 002/X/A(27)01 and as specified

Allow for dressing roofing system in to and around rain water roof outlets

Solar reflective second layer of self-adhesive reflective aluminium membrane for exposed roofing as specification

Extruded polyurethane rigid foam insulation board (density 55kg/CUM)as specified

1000G Polythene sheet (Min. lapping 300mm) separation layer as detailed

Page 39: Bill No 4, Samad Hanger

1142.04.2012 4.5/39Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Roofing 4.5

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

ROOFING (Cont'd)

COVERING AND LINING (Cont'd)

Roof finish

A 1,475 m2

Miscellaneous items

B

Item

C Allow for waterproofing to duct cover slabs as specifiedItem

D

344 m

300 x 300 x 30mm Thick concrete paving slabs laid on and including 30mm thick levelling screed as detail

Allow for dressing roofing system in to and around pipe work, plinths, column bases etc. on roof to make a complete roofing system

Forming of 20 x 20mm groove in parapet to receive waterproofing membrane and solar shield (measured separately)

Page 40: Bill No 4, Samad Hanger

1142.04.2012 4.5/40Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Roofing 4.5

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

ROOFING (Cont'd)

COVERING AND LINING (Cont'd)

SCREED

A 1,475 m2

B 1,475 m2

C 50 x 50mm Angle fillet in PCC (1:3:6, 10mm) 344 m

Roof Cladding

D

5,688 m2

E 55 m

F 109 m

Gitem

70mm (minimum) Thick screed laid to falls on roof slab as specified

30mm Thick levelling screed over 1000G Polythene membrane (Measured separately) as specified

Insulated standing beam aluminium roofing system complete with internal insulation, Structural deck (measured separately) including all fixing accessories as shown on drawing 002/MU/04/A(21)02 and detailed drawing 002/MU/A(27)02 and as otherwise specified.

Extra over insulated valley gutters, 1000mm girth (Centre gutter)

Extra over insulated valley gutters, 1650mm girth (Outer gutter)

Allow provision for fixing rainwater outlets (Approx. 15 No)

Page 41: Bill No 4, Samad Hanger

1142.04.2012 4.5/41Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Roofing 4.5

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

ROOFING (Cont'd)

COVERING AND LINING (Cont'd)

Roof Light

A Extra over roof light overall size 1600 x 800mm 128 No

Flashing

B Pressed eave flashing 1120mm girth 109 m

C Ditto, verge flashing 560mm girth 104 m

SUNDRIES

Testing

DItem

E Allow for testing for roof cladding areas Item

Supply, fully fabricate and erect in position, roof light comprising supporting frame, 45 x 45 x 2mm cleader angles, flashing and glass covering to manufacturers details and as specified

Allow for flood test to a depth of 50mm for continuous 24hour period for concrete roof areas

Page 42: Bill No 4, Samad Hanger

1142.04.2012 4.5/42Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Roofing 4.5

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

COLLECTION

4.5/1

4.5/2

4.5/3

4.5/4

Page 43: Bill No 4, Samad Hanger

1142.04.2012 4.5/43Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Roofing 4.5

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

ROOFING Carried to Summary of Bill No. 4 R.O.

Page 44: Bill No 4, Samad Hanger

1142.04.2012 4.6/44Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Door & Frames 4.6

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

DOORS AND FRAMES

1) All hardwood shall be best quality as specified

2) Sizes stated are structural opening sizes

3) Door leaf/jambs, heads and meeting styles of all

A 10 No

B

5 No

C 17 No

Note: Rates for doors and frames measured as door-sets shall also include for the following:

external doors to be sealed with approved weather strips and neoprene gasket

4) Approved type damp proof membrane for, all faces, edges and ends of timber in contacts with concrete, block work, plaster, render, marble or metal surfaces

44mm thick solid core timber flushed door with 4mm commercial plywood facing complete with frames 150 x 50mm, sub frames, 6mm hard wood lipping, and architraves etc., fixed to concrete or block works including all fixing accessories, ironmongery (measured separately), two coats of anti termite, wood preservative, prepare surface and finished with polyurethane varnish/paint as specified

Single leaf flush door, type D1, overall size 1000 x 2200mm

Single leaf flush door, type D4, overall size 900 x 2200mm complete with 100 x 700mm view glass panel

Single leaf flush door, type D5, overall size 1000 x 2200mm

Page 45: Bill No 4, Samad Hanger

1142.04.2012 4.6/45Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Door & Frames 4.6

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

DOORS AND FRAMES (Cont'd)

A

2 No

B

1 No

44mm thick solid core timber flushed door with 4mm commercial plywood facing complete with frames 150 x 50mm, sub frames, 6mm hard wood lipping, and architraves etc., fixed to concrete or block works including all fixing accessories, ironmongery (measured separately), two coats of anti termite, wood preservative, prepare surface and finished with polyurethane varnish/paint as specified (Cont"d)

Double leaf flush door, type D15, overall size 1800 x 2200mm, complete with 800 x 580mm 2 No. view glass (pyrostop 120-106) panels - fire rating FD120S

Double leaf flush door, type D16, overall size 1800 x 2200mm, complete with 800 x 580mm 2 No. toughened glass view panels

Page 46: Bill No 4, Samad Hanger

1142.04.2012 4.6/46Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Door & Frames 4.6

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

COLLECTION

4.5/1

4.5/2

Page 47: Bill No 4, Samad Hanger

1142.04.2012 4.6/47Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Door & Frames 4.6

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

DOORS AND FRAMES Carried to Summary of Bill No. 4 R.O.

Page 48: Bill No 4, Samad Hanger

1142.04.2012 4.7/48Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Carpentry & Joinery 4.7

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) R.O

CARPENTRY AND JOINERY

FITTED FURNITURE

Vanity Counter

A 1 No

B 1 No

Work Bench

C Overall size 10000m x 600mm wide, for room No. G15 2 No

D Allow work benches, for room No. G20 (approx 4 No) Item

E Ditto, for room No. G27 (Approx.6No) Item

F Ditto, for room No. G31 (Approx. 5No) Item

Wall Vertical

GItem

Note - Rate to include for approved type damp proof membrane for all faces, edges and ends of timber in contacts with concrete, block work, plaster, render, marble or metal surfaces as specified

Vanity counter with granite vanity top comprising framework as required, high quality aluminium shutters, back linings, skirting, including all finishes & ironmongery, all fitting and fixing accessories etc. as drawing ref.002/MU/04/AR-14 & 15 and as specification

Vanity counter, 3400 x 600mm wide including 4 No. cut outs for wash basing

Ditto, 2600 x 600mm wide including 3 No. cut outs for wash basing

Timber work bench complete with all fittings and fixing accessories, decorative paint finishes etc. as specified in room data sheets

Allow for wall vertical as room data sheet, for room No. G31 (Approx. 2No)

Page 49: Bill No 4, Samad Hanger

1142.04.2012 4.7/49Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Carpentry & Joinery 4.7

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) R.O

To Collection R.O.

CARPENTRY AND JOINERY

FITTED FURNITURE

Counter Units

A

1 No

B

1 No

C 1 No

Overhead Cabinet unit

D 1800mm long 2 No

E 2300mm long 1 No

Counter unit and granite counter top complete with supporting frame, back linings, all fittings and fixing accessories, ironmongery including splash back and decorative finishes as layout drawing ref. 002/MU/04/AR-01 and as specified in room data sheet

4300 x 600mm Wide, "L" shaped base counter unit including 1 No. cut-out for sink and breakfast counter with stainless steel support

3200 x 600mm Wide, "L" shaped base counter unit including 1 No. cut-out for sink and breakfast counter with stainless steel support

2300 x 600mm Wide, base counter unit including 1 No. cut-out for sink

Overhead cabinet unit made with waterproofed laminate plywood complete with supporting frame, back linings, all fittings and fixing accessories, decorative finishes as room data sheets and drawings

Page 50: Bill No 4, Samad Hanger

1142.04.2012 4.7/50Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Carpentry & Joinery 4.7

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) R.O

To Collection R.O.

CARPENTRY AND JOINERY

FITTED FURNITURE

Locker units

A Lockers at rooms G06 & G22 55 No

Wardrobes

BItem

Notice Board

C Overall size 1800 x 1200mm, for room No. G11 1 No

Locker units in locker rooms as shown on drawing ref.002/MU/04/AR-04 and specifications

Allow for wardrobes where necessary as specification and detail drawing No. 00-x-a(71)

Wall mounted notice board complete with teak wood frame, green cloth, pinup backing and all fixing accessories as room data sheet and drawings

Page 51: Bill No 4, Samad Hanger

1142.04.2012 4.7/51Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Carpentry & Joinery 4.7

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) R.O

To Collection R.O.

COLLECTION

4.6/1

4.6/2

4.6/3

Page 52: Bill No 4, Samad Hanger

1142.04.2012 4.7/52Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Carpentry & Joinery 4.7

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) R.O

CARPENTRY AND JOINERY Carried to Summary of Bill No. 4 R.O.

Page 53: Bill No 4, Samad Hanger

1142.04.2012 4.8/53Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Finishes 4.8

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FINISHES

INTERNAL FINISHES

Plastering

Note:

A To walls (Up to ceiling) 4690 m2

B Ditto, (above ceiling) 565 m2

1.Plastering rates are to include forming recess panels, working on projections and the like, if these items are not specifically measured

Plastering to walls; 15-20mm thick to receive paint finish including MS corner beads and all related works, applied in accordance with the specifications and drawings

Page 54: Bill No 4, Samad Hanger

1142.04.2012 4.8/54Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Finishes 4.8

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

FINISHES

INTERNAL FINISHES (Cont'd)

Floor Finishes

A 300 x 300 x 30mm Thick, to floors 590 m2

B Ditto, to stair landings 25 m2

C 119 m

D 20mm Thick, 160mm High terrazzo step riser 124 m

E 100mm High terrazzo skirting, fixed to walls 25 m

F 358 m

G95 m

H 100mm High vinyl skirting fixed to walls 270 m

Precast terrazzo tiles with contrasting colour boarder on and including floating sand cement screed bedding with all necessary grout and sealant as approved and specified

30mm Thick 260mm wide terrazzo step treads including 2 Nos. of carborundum strips

100mm High terrazzo tile, top edge splayed skirting fixed to walls

100mm High terrazzo tile, top edge splayed skirting fixed to staircase & stair well walls

Vinyl tiles fixed on plastered walls including adhesive as specified

Page 55: Bill No 4, Samad Hanger

1142.04.2012 4.8/55Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Finishes 4.8

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

FINISHES

INTERNAL FINISHES (Cont'd)

Floor Finishes (Cont'd)

A 200 x 200mm to floors 38 m2

B 100mm High coved tile skirting fixed to walls 82 m

C To floors 1240 m2

D To hanger floors 5141 m2

E Laid on raised access floor system 27 m2

Fully vitrified non slip porcelain floor tiles, with contrasting colour boarder on and including floating sand cement screed bedding with all necessary grout and sealant as approved and specified

Industrial epoxy resin floor paint system including floor hardener, applied on and including floating sand cement screed, in accordance with manufacturers recommendations and as per drawings and specification

High performance Industrial epoxy / polyurethane floor paint system, applied on and including cement sand floating screed, in accordance with manufacturers recommendations and as per drawings and specification

Selected carpet or carpet tiles, on raised floors fixed in accordance with manufacturers recommendations, as specified.

Page 56: Bill No 4, Samad Hanger

1142.04.2012 4.8/56Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Finishes 4.8

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

FINISHES

INTERNAL FINISHES (Cont'd)

Floor Finishes (Cont'd)

A To floor and steps at staff entrance 23 m2

B Allow for granite thresholds where necessary Item

Raised Floor System

C 400mm high raised access floors 27 m2

D 200mm high raised access floors 534 m2

Selected and approved granite flooring on and including floating sand cement screed bedding with all necessary grout and sealant as specified

Allow for raised access floor system, complete with access floor tiles, adjustable access floor pedestals over reinforced concrete surface including surface applied damp proof membrane, as per drawings and specifications. (Finishes measured separately)

Page 57: Bill No 4, Samad Hanger

1142.04.2012 4.8/57Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Finishes 4.8

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

FINISHES

INTERNAL FINISHES (Cont'd)

Wall Finishes

A 200 x 200mm, to walls 180 m2

Ceramic wall tiles , including corner tiling / coving skirting (measured separately) on and including necessary bedding with all fixing, grout and sealant, proprietary PVC corner beads all as specified and approved

Page 58: Bill No 4, Samad Hanger

1142.04.2012 4.8/58Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Finishes 4.8

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

FINISHES

INTERNAL FINISHES (Cont'd)

Ceiling Finishes

A To soffits of suspended slabs 49 m2

B To soffit of staff entrance 12 m2

1. All ceilings are measured flat on plan, rates shall include for approved suspension system backing boards bulkheads and the like

2. Rates for ceilings shall include for all necessary builders works, supports etc, cut outs for lighting, AC diffusers or the like shall be included in the rate for suspended ceilings

Gypsum vinyl tile Suspended ceiling tiles 600 x 600mm ceiling tiles, with aluminium foil backing and flush mounted access panels laid on exposed grid system with plain painted finish as per specification and drawings

Gypsum suspended ceiling, laid on and including exposed grid system, decorative cornice, provision for concealed light fittings and painted finish as per specification and drawings

Acoustic ceiling tiles 600mm x 600mm suspended ceiling with and flush mounted access panels laid on exposed grid system, including exposed self finished proprietary suspension grid system with painted finish as per specification and drawings

Page 59: Bill No 4, Samad Hanger

1142.04.2012 4.8/59Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Finishes 4.8

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

C To soffits of suspended slabs 716 m2

To Collection R.O.

FINISHES

INTERNAL FINISHES (Cont'd)

Sundries

Wet Area Waterproofing

A To floor & walls 54 m2

BItem

Expansion Joint

CItem

Sound Insulation

D Acoustic insulation at engine bay area walls as specified832 m2

E 548 m2

Signage

Prepare surface and apply cold applied waterproofing system to floor and walls (200mm above FFL) including sand/cement fillets as detail D3, drawing ref. 002/MU/A(43)01 and as specified

Allow for waterproofing of ditch channel (inside and out side)

Allow for required finishes for roof expansion joint as specified (Approx. 16m)

Acoustic insulation at engine bay area ceiling as specified

Page 60: Bill No 4, Samad Hanger

1142.04.2012 4.8/60Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Finishes 4.8

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

F Allow for signage for safety, fire exit, equipments etc..Item

To Collection R.O.

FINISHES

EXTERNAL FINISHES

Plastering

Note:

A To walls / plinths 2,210 m2

Plastering rates are to include forming recess panels, working on projections and the like, if these items are not specifically measured

18mm thick cement/sand external render system to receive paint finish including all related works, applied in accordance with the specifications and drawings

(Note- External pavements around building measured elsewhere)

Page 61: Bill No 4, Samad Hanger

1142.04.2012 4.8/61Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Finishes 4.8

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

COLLECTION

4.8/1

4.8/2

4.8/3

4.8/4

4.8/5

4.8/6

4.8/7

4.8/8

Page 62: Bill No 4, Samad Hanger

1142.04.2012 4.8/62Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Finishes 4.8

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FINISHES Carried to Summary of Bill No. 4 To Collection R.O.

Page 63: Bill No 4, Samad Hanger

1142.04.2012 4.9/63Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Painting & Decorating 4.9

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

PAINTING AND DECORATING

A To walls 2,802 m2

B To exposed soffits 631 m2

C To walls 1,888 m2

D To exposed soffits 500 m2

E To external walls 2,210 m2

Paint system to internal plastered/exposed surfaces with matt emulsion, washable/durable/stain resistant with primer and stucco, as detailed on specification

Paint system to internal plastered/exposed surfaces with high gloss enamal paint, washable/durable/stain resistant with primer and stucco, as detailed on specification

Paint system to external plastered surfaces, medium

textured, weather coat external paint as detailed on

room data sheets including all necessary related works,

all in accordance with specifications and drawings

Page 64: Bill No 4, Samad Hanger

1142.04.2012 4.9/64Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Painting & Decorating 4.9

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

PAINTING AND DECORATING Carried to Summary of Bill No. 4 To Collection R.O.

Page 65: Bill No 4, Samad Hanger

1142.04.2012 4.10/65Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Ironmongery 4.10

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

IRONMONGERY

DOORS (For Timber doors)

A114 No

B32 No

C Dead lock and strike plate profile cylinder (3 Keyed) 1 No

D11 No

E22 No

F OH Heavy duty door closer 38 No

G Floor / wall mounted door stop 34 No

H S/S Hat and coat hook 27 No

J 150 x door width, kick plates 28 No

K27 No

L1 No

Supply and installation of following ironmongery sets complete with all accessories; fixings and the like, stainless steel finish, to conform to the specifications and drawings, including grand master key system and complying to all particular notes referred to on the ironmongery schedule

Butt hinges 102 x 76mm including stainless steel ball bearings (1.5 pair per leaf)

Sash lock and strike plate upright lock set (3 Keyed) 76 mortise profile cylinder

22mm Dia. Pull handle on and including rectangular back plate and concealed fixing screws

22mm Dia. Pull handle on and including square back plate (160 x 160mm) and concealed fixing screws

EX 100 x 300mm (varies), 3mm thick, aluminium name plate

Leaver action flush bolts with dust excluding socket (2 pairs)

Page 66: Bill No 4, Samad Hanger

1142.04.2012 4.10/66Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Ironmongery 4.10

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

IRONMONGERY (Cont'd)

DOORS (For Timber doors) cont'd

A5 No

B

2 No

C2 No

Supply and installation of following ironmongery sets complete with all accessories; fixings and the like, stainless steel finish, to conform to the specifications and drawings,…………. (Cont'd)

76mm Dia., 2mm thick aluminium, Male / Female toilet signs

RIM Push pad panic latch with outside access device for single leaf. combine unit for double doors

Aluminium push plates, marked "PUSH" size 450 x 100 x 2mm thick with radius ends

Page 67: Bill No 4, Samad Hanger

1142.04.2012 4.10/67Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Ironmongery 4.10

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

COLLECTION

4.10/1

4.10/2

Page 68: Bill No 4, Samad Hanger

1142.04.2012 4.10/68Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Ironmongery 4.10

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

IRONMONGERY Carried to Summary of Bill No. 4 R.O.

Page 69: Bill No 4, Samad Hanger

1142.04.20124.11/69

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Equipments 4.11

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

EQUIPMENTS

Overhead Crane

A

2 No

B

2 No

5ton Overhead crane in hanger area complete with all fixing accessories and final power supply connections as specified

5ton Full span two ways overhead crane in engine bay complete with all fixing accessories and final power supply connections as specified

(Note - Crane rails measured under structural metal works)

Page 70: Bill No 4, Samad Hanger

1142.04.20124.11/70

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Equipments 4.11

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

EQUIPMENTS Carried to Summary of Bill No. 4 R.O.

Page 71: Bill No 4, Samad Hanger

1042.04.20124.12/71

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

Page 72: Bill No 4, Samad Hanger

1042.04.20124.12/72

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FIRE FIGHTING INSTALLATIONS

SPRINKLER AND HOSE REEL SYSTEM

Fire hose reel & foam hose reel system

A 63mm Diameter pipe 5 m

B2 No

C 50mm Diameter pipe 295 m

D 65mm Diameter pipe 283 m

E41 No

F 80mm Diameter pipe 28 m

G4 No

PLUMBING AND SANITARY INSTALLATIONS (Cont'd)

HDPE(Pn20) pipes and fitting to CP 312 part 3 laid under ground including all necessary excavation, backfilling, bed and surround, as specified

Extra over 63mm diameter pipe for fittings and accessories

Galvanized heavy weight seamless mild steel pipe and fittings to BS 1387 class-B ERW as specified

Extra over 65mm diameter pipe for fittings and accessories

Extra over 80mm diameter pipe for fittings and accessories

Page 73: Bill No 4, Samad Hanger

1042.04.20124.12/73

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

FIRE FIGHTING INSTALLATIONS (Cont'd)

WET RISER AND HOSE REEL SYSTEM (Cont'd)

Foam monitoring Pipe

A 150mm Diameter pipe 560 m

B142 No

Supply and install equipment, as specified

C

15 No

D

4 No

E

6 No

PLUMBING AND SANITARY INSTALLATIONS (Cont'd)

Galvanized heavy weight seamless mild steel pipe and fittings to BS 1387 class-B ERW as specified (Cont'd)

Extra over 150mm diameter pipe for fittings and accessories

100mm dia Foam monitor unit complete with butterfly valve, deluge valve, O.S & Y gate valve , oscillating foam monitor as detailed in drawing No 002/MU/04/2038/FH-5001

Fire hose reel 19mm diameter, 30meter long, complete with 1No 25mm dia gate valve, 1No 25mm dia pressure regulating valve, 1No 5kg Co2 fire extinguisher, 1No 9Ltr foam fire extinguisher, cabinet all accessories as specified and detailed on drawing No. 002/MU/04/2038/FH-5001

Foam hose reel station consists with hand fire nozzle,1.5" galvanised hose reel and rubber hose grass bypass manifold as per drawing No 002/MU/04/2038/FH-5001

Page 74: Bill No 4, Samad Hanger

1042.04.20124.12/74

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

Page 75: Bill No 4, Samad Hanger

1042.04.20124.12/75

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FIRE FIGHTING INSTALLATIONS (Cont'd)

WET RISER AND HOSE REEL SYSTEM (Cont'd)

Supply and install equipment, as specified (Cont'd)

A CO2, 5 kg fire extinguisher 2 No

B Co2 -5kg+Dry powder-5Kg extinguisher 8 No

C Co2-5Kg +AFF-9L+Dry powder-5kg extinguisher 1 No

D Dry powder -2x50kg extinguisher 8 No

EItem

F

6 No

PLUMBING AND SANITARY INSTALLATIONS (Cont'd)

Allow for fire extinguisher recessed cabinets as shown on drawing

Potable twin trolley telescopic applicator shall be extended upto 2m, with shed cocoer kit mark equivalent conforming to BSEN -hose 6m long single cylinder-CO2 -10kg , 2No 90L Foam- & 1 No 9kg dry powder extinguisher as detailed in drawing 002/MU/04/2038/FH-5001

Page 76: Bill No 4, Samad Hanger

1042.04.20124.12/76

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

Page 77: Bill No 4, Samad Hanger

1042.04.20124.12/77

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FIRE FIGHTING INSTALLATIONS (Cont'd)

SPRINKLER SYSTEM

A 25mm Diameter pipe 649 m

B 32mm Diameter pipe 614 m

C 40mm Diameter pipe 313 m

D 50mm Diameter pipe 92 m

E 65mm Diameter pipe 66 m

F23 No

G 80mm Diameter pipe 163 m

H29 No

J 100mm Diameter pipe 230 m

K72 No

L 150mm Diameter pipe 462 m

M75 No

PLUMBING AND SANITARY INSTALLATIONS (Cont'd)

Galvanized heavy weight seamless mild steel pipe and fittings to BS 1387 class-B ERW as specified

Extra over 65mm diameter pipe for fittings and accessories

Extra over 80mm diameter pipe for fittings and accessories

Extra over 100mm diameter pipe for fittings and accessories

Extra over 150mm diameter pipe for fittings and accessories

Page 78: Bill No 4, Samad Hanger

1042.04.20124.12/78

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

Page 79: Bill No 4, Samad Hanger

1042.04.20124.12/79

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FIRE FIGHTING INSTALLATIONS (Cont'd)

SPRINKLER SYSTEM (Cont'd)

A 300mm Diameter pipe 7 m

B8 No

Supply and install equipment, as specified

C

5 No

D

2 No

Accessories as specified and detailed on drawings

E Automatic air vent fixed on 25mm diameter Pipe 9 No

F

1 No

PLUMBING AND SANITARY INSTALLATIONS (Cont'd)

Galvanized heavy weight seamless mild steel pipe and fittings to BS 1387 class-B ERW as specified (Cont'd)

Extra over 300mm diameter pipe for fittings and accessories

Foam water sprinkler(open type ) in hanger area Zone control valve and flow switch assembly including valves with foam propotioner and complete with all necessary accessories, equipments to suit proposed system as detailed on drawing No 002/MU/04/2038/FH-5001 and as specified

Pendant pre-action sprinkler alarm Zone control valve and flow switch assembly including valves and all interconnection as detailed in drawing No 002/MU/04/2038/FH-5001

Valve chamber with 1 No 63mm Isolating valve & 1No 63mm Pressure reducing valve as detailed in drawing.

Page 80: Bill No 4, Samad Hanger

1042.04.20124.12/80

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

Page 81: Bill No 4, Samad Hanger

1042.04.20124.12/81

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FIRE FIGHTING INSTALLATIONS (Cont'd)

SPRINKLER SYSTEM (Cont'd)

Sprinkler unit with connecting to pipe work

A Foam water type sprinkler head 406 No

B Pre action type sprinkler head 152 No

Supply and install equipment, as specified

C 1 No

D 1 No

E 1 No

SPARE PART

F

Item

Others

G

PLUMBING AND SANITARY INSTALLATIONS (Cont'd)

Fire suppression system including control panel, detector panel, emergency pull station, spray nozzles pipe works fire suppression clean agent cylinders capacities as specified by specialised contractor.

Signal Room (18m2)

Signal Room (9m2)

Engine Bay (543.5m2)

Allow for supply of tools and spare parts for fire fighting system installation as listed in Engineer's schedule for maintenance of plant and equipment as specified

Contractor shall list here other items not included above but necessary for the complete and satisfactory completion of this section of the works. Such items shall be deemed to be included unless specifically listed here.

Page 82: Bill No 4, Samad Hanger

1042.04.20124.12/82

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

A

Item

BItem

CItem

D

Item

PLUMBING AND SANITARY INSTALLATIONS (Cont'd)

BUILDER'S WORK IN CONNECTION WITH PLUMBING AND SANITARY INSTALLATIONS

Allow for providing sleeves for ducts and pipes passing through walls and slabs with forming openings and making good

Allow for fire sealing gaps between sleeves, holes openings and ducts, pipes and the like

Allow for necessary pipe supports, bracket fixings and the like

Allow for any excavation of trenches up to 1200mm deep necessary for laying any internal pipe work and the like, including providing necessary concrete bed and surround to pipes below grade slab

Page 83: Bill No 4, Samad Hanger

1042.04.20124.12/83

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

Page 84: Bill No 4, Samad Hanger

1042.04.20124.12/84

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

SUNDRIES

A

Item

BItem

C

Item

DItem

E Allow for sterilisation of pipe work, as specified Item

FItem

G

Item

HItem

JItem

K

Item

PLUMBING AND SANITARY INSTALLATIONS (Cont'd)

Allow for coordinating with all other engineering installations, setting out the work and marking positions of all holes, mortises, chases and the like

Allow for all protective and decorative painting, as specified

Allow for identification labels,. plates, charts and identification of plant, equipment, pipe work, controls and the like

Allow for earthling bonding to all items of pipe work, fittings, and fixtures and equipment

Allow for providing documents and operating instructions and maintenance manuals

Allow for protection of entire hot and cold water installation against any form of back siphonage in accordance with BS 476

Allow for providing 'As built' drawings and process negatives, as specified

Allow for testing and commissioning the plumbing and sanitary installations

Allow for all other incidental work and ancillary items as required for a complete installation of plumbing and sanitary installations

Page 85: Bill No 4, Samad Hanger

1042.04.20124.12/85

Commercial in Confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Mechanical Engineering

Installation 4.12

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

COLLECTION

4.12/1

4.12/2

4.12/3

4.12/4

4.12/5

4.12/6

4.12/7

4.12/8

4.12/9

4.12/10

4.12/11

4.12/12

4.12/13

4.12/14

4.12/15

4.12/16

4.12/17

Page 86: Bill No 4, Samad Hanger

1142.04.2012 4.13/86Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

Page 87: Bill No 4, Samad Hanger

1142.04.2012 4.13/87Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FIRE ALARM SYSTEM INSTALLATIONS

A Addressable type smoke detector below false ceiling 37 No

B 10 No

C Addressable type smoke detector above false ceiling 6 No

D Heat detector 21 No

E Fire alarm manual break glass call point 16 No

F Fire alarm electronic sounder 4 No

G Fire alarm strobe light 3 No

H Fire alarm strobe light - weather proof 18 No

J Flame detector 4 No

K Response indicator 6 No

INTERNAL ELECTRICAL INSTALLATIONS (Cont'd)

cable and conduit to fire alarm points in concealed installations, as specified

Addressable type combined detector below false ceiling

Page 88: Bill No 4, Samad Hanger

1142.04.2012 4.13/88Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

Page 89: Bill No 4, Samad Hanger

1142.04.2012 4.13/89Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FIRE ALARM SYSTEM INSTALLATIONS (Cont'd)

A Video Smoke detection camera wall mounted 12 No

B Fire exit Signs 12 No

C Exit directional signs 2 No

Accessories, as specified and detailed on drawings

D Addressable type smoke detector below false ceiling 37 No

E 10 No

F Addressable type smoke detector above false ceiling 6 No

G Heat detector 21 No

H Fire alarm manual break glass call point 16 No

J Fire alarm electronic sounder 4 No

K Fire alarm strobe light 3 No

INTERNAL ELECTRICAL INSTALLATIONS (Cont'd)

cable and conduit to fire alarm points in concealed installations, as specified (Cont'd)

Addressable type combined detector below false ceiling

Page 90: Bill No 4, Samad Hanger

1142.04.2012 4.13/90Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

Page 91: Bill No 4, Samad Hanger

1142.04.2012 4.13/91Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FIRE ALARM SYSTEM INSTALLATIONS (Cont'd)

A Fire alarm strobe light - weather proof 18 No

B Flame detector 4 No

C Response indicator 6 No

D Video Smoke detection camera wall mounted 12 No

E Fire exit Signs 12 No

F Exit directional signs 2 No

G 4 loop digital addressable fire alarm panel 1 No

H Video Smoke detection control rack 1 No

INTERNAL ELECTRICAL INSTALLATIONS (Cont'd)

Accessories, as specified and detailed on drawings (Cont'd)

Equipment and control gear, as specified and connected to power source; all as detailed and shown on drawings

Page 92: Bill No 4, Samad Hanger

1142.04.2012 4.13/92Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

Page 93: Bill No 4, Samad Hanger

1142.04.2012 4.13/93Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

FIRE ALARM SYSTEM INSTALLATIONS

A Allow interface with PA system Item

B Ditto, FM 200 Item

C Ditto, AHU, fuem Extract Fan Item

D Ditto, Sprinkler system Item

E Ditto, Video smoke detection system Item

F Ditto, Existing fire alarm control panel Item

G Ditto, fire dampers / louvers Item

HItem

INTERNAL ELECTRICAL INSTALLATIONS (Cont'd)

Fire retardant cable and conduiting to interface panels form fire alarm system installations, as specified

Allow for any other requirement not specifically included in this Bill but necessary for the proposed Fire Alarm system installation

Page 94: Bill No 4, Samad Hanger

1142.04.2012 4.13/94Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

Page 95: Bill No 4, Samad Hanger

1142.04.2012 4.13/95Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

SMATV SYSTEM INSTALLATIONS

A FM/Television socket outlet point 3 No

B FM/Television socket outlet 3 No

C 2 No

D 2 No

E 200 x200 x100mm Junction box 2 No

INTERNAL ELECTRICAL INSTALLATIONS (Cont'd)

cable and conduit to television outlet points in concealed installation, as specified

Approved accessories, as specified and detailed shown on drawing

Approved equipments, as specified and power supply connection where necessary as detailed shown on detail drawings

4 feet Satellite Dish Antenna - ARAB SAT complete with signal cable and connected to the system

4 feet Satellite Dish Antenna - NILE SAT complete with signal cable and connected to the system

Page 96: Bill No 4, Samad Hanger

1142.04.2012 4.13/96Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

To Collection R.O.

Page 97: Bill No 4, Samad Hanger

1142.04.2012 4.13/97Comercial in confidential

MOD/RAFO BILL NO. 4PACKAGE - 1 HANGERMUSANAH (SAMAD) Electrical Engineering

Installation 4.13

ITEM DESCRIPTION RATE AMOUNTNO. QTY. UNIT (R.O.) (R.O)

Carried to Summary of Bill No. 4 Summary R.O.

ELECTRICAL ENGINNERING INSTALLATION