bill of quantities - interior works admin block ...technical specification interior works 3 three...

26
Technical Specification Interior Works 1 BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK (CIVIL WITH PANNEL WORK)- DTCAMU Sl. No. Description Of Item Unit Quantity RATE AMOUNT PART A-CIVIL WORKS 1 Brick Work Providing and laying brick masonry above plinth for superstructure, for walls, pillars, steps, parapet, cabin and other similar locations etc with well burnt good quality bricks of class designation 75 in cement mortar 1:6 (1 cement : 6 sand) in true line, level and plumb including racking the joints upto 20mm depth, rubbing and cleaning the surface, with necessary scaffolding, curing etc., complete as directed and specified at all heights & levels. cum 5.00 2 Half Brick Wall Providing and laying half brick partition walls with well burnt good quality of class designation 75 in cement mortar 1:4 (1cement : 4 coarse sand) including providing 2 Nos. of 6mm dia M.S. round bars at every IVth course, including scaffolding, curing, rubbing the surface, racking out the joints etc., complete as directed and specified for walls, parapet, platform supports etc. at all floor heights & levels.(for straight & curved wall) sqm 65.00

Upload: others

Post on 01-Sep-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

1

BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK (CIVIL WITH PANNEL WORK)- DTCAMU

Sl. No.

Description Of Item Unit Quantity RATE AMOUNT

PART A-CIVIL WORKS

1 Brick Work

Providing and laying brick masonry above plinth for superstructure, for walls, pillars, steps, parapet, cabin and other similar locations etc with well burnt good quality bricks of class designation 75 in cement mortar 1:6 (1 cement : 6 sand) in true line, level and plumb including racking the joints upto 20mm depth, rubbing and cleaning the surface, with necessary scaffolding, curing etc., complete as directed and specified at all heights & levels. cum 5.00

2 Half Brick Wall

Providing and laying half brick partition walls with well burnt good quality of class designation 75 in cement mortar 1:4 (1cement : 4 coarse sand) including providing 2 Nos. of 6mm dia M.S. round bars at every IVth course, including scaffolding, curing, rubbing the surface, racking out the joints etc., complete as directed and specified for walls, parapet, platform supports etc. at all floor heights & levels.(for straight & curved wall) sqm 65.00

Page 2: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

2

3 Cement Plaster

Providing and laying 12-15mm thick plaster in cement mortar 1:4:2 (1cement : 4 fine sand : 2 coarse sand) to all types of RCC work (small or big) brick/stone work surfaces including parapet, wall tops, jambs and cills etc.at all levels, in line, level and plumb as shown in detailed drawings, including smooth cement finish, as directed including providing necessary bands, drip moulds, tapak, grooves at all the junctions of walls and ceiling, walls and frames for doors or windows, around skirting/dado or at other places as directed, including raking the joints or roughening the RCC surfaces, necessary curing, scaffolding etc., complete as directed and specified. sqm 250.00

4 Cement Concrete Under Floor

Providing and laying cement concrete under floors etc. at all level including the cost of centring, shuttering & finishing.

a)

1:3:6(1 cement:3coarse sand:6 graded stone aggregate 20mm nominal size) cum 30.00

5 Tapecrete water proofing

Providing, applying & testing water proofing treatment of RCC sunken slabs (toilets etc) comprising of the following operations.

Cleaning RCC surfaces and plastering of RCC and brick wall surface with 12mm cement mortar 1:4 ( 1 cement : 4 coarse sand) mixed with CICO admixture as per manufacturer's specifications.

Page 3: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

3

Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third layer to be @ 0.126kg/sqm ) each admixed with grey cement over a coat of neat cement slurry admixed with chemical CH - 9 and sealing all corners, joints, junction of pipes and masonry etc. with Epoxy putty all complete as per manufacturer's specification and drawing.

12mm thick protective plaster 1:4 (1 cement : 4 coarse sand) over treated surface etc complete. (Quoted rate to include grouting of RCC surface for any cracks/ fissures) sqm. 60.00

Total

PART B-FLOORING & DADO WORKS

Note:

For all item of stone and tile the contractors should see the approved sample board at the office of the architect and should also submit their own sample alongwith the tender.

1 Cement Concrete Flooring

Page 4: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

4

Providing and laying . cement concrete (Indian Patent Stone) for flooring, treads of steps etc. using cement concrete1:2:4 (1 cement : 2 coarse sand : 4 aggregate 20mm and down gauge) for floors, flooring bands, cills, treads of steps and other similar locations, tamped, spaded, trowelled and top finished neat , smooth with a floating coat of cement as directed, laid in alternate panels of area not more than 2.00 sqm and laid to water level or proper slope as directed with necessary shuttering , providing and fixing 40mm x 2mm thick PVC dividing strips, curing etc., complete at all heights & levels as per details shown in the drawing.

a. 40 mm thick sqm 50.00

2 Cement Plaster Skirting

Providing and laying cement plaster skirting with cement mortar 1:3 (1 cement:3 coarse sand) finished with neat cement coat at all height. sqm 5.00

3 Stone In Stair.

Providing and fixing single piece pre-polished granite stone on stair treads, risers, skirting & landings laid over 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) mix, including cutting of stone, antiskid grooves, nosing, white cement slurry, matching pigment, moulded & polished edges, grooves etc. complete as per design and drawing.

a) Treads .

i)

Granite Stone (basic rate of stone Rs 140 / sqft)Including all taxes & tranportation ) sqm 15.00

Page 5: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

5

b) Risers.

i)

Granite Stone (basic rate of stone Rs 140 / sqft)Including all taxes & tranportation ) sqm 10.00

c) Skirting

i)

Granite Stone (basic rate of stone Rs 140 / sqft)Including all taxes & tranportation ) sqm 5.00

4 Vitrified Tile Flooring & Skirting

Providing and laying 9.5 mm thick vitrified tiles of approved quality and shade for flooring & skirting over a bed of 20mm thick cement mortar 1:4 (icement : 4 coarse sand) , laid to patterns with 2-3 mm grooves , including necessary cutting, mitring, grouting of joints with 'BAL' epoxy based grout (grey) / white antifungal grout applying silicon sealents between the junction of floor & wall, etc., complete as per detailed drawings at all levels.

a) Unpolished tile (basic price Rs. 60/sft) sqm 50.00

b) Polished tile (basic price Rs. 75/sft) sqm 585.00

C) P/F dark colour tiles (basic price Rs. 150/sft) sqm

5 Ceramic Tile Dado

Page 6: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

6

Providing and laying 9.5 mm thick ceramic tiles of approved quality and shade for dado over a bed of 12mm thick cement mortar 1:4 (icement : 4 coarse sand) , laid to patterns with 2-3 mm grooves , including necessary cutting, mitring, grouting of joints with 'BAL' epoxy based grout (grey) / white antifungal grout applying silicon sealents between the junction of floor & wall, etc., complete as per detailed drawings at all levels.

a) Polished tile (basic price Rs. 75/sft) sqm 150.00

6 Laminated wooden flooring

Providing and laying laminated wooden flooring ( for commercial use)of approved make ( sharper image) make and as per approved sample, colour and laid on the existing levelled flooring with approved adhesive & underlay including skirting beading & profile etc. complete as per manufacturers specification & approval of Architect (basic rate to be considered @ Rs.65/- sft.). sqm 50.00

Total

PART C-DOORS, WINDOWS AND GLAZING

1 Door Frame

Providing, making and fixing in position selected woods in frames, transoms, mullions, cills, etc., of doors, windows, made to size and shape as shown, with mitered joints, fixed with holdfasts/cleats / threaded expansion bolts to rough grounds / masonry including making 10mm

Page 7: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

7

thick grooves with laminate finished etc. including two coats of fire retardant (viper) & anti-termite paint on concealed surfaces, rebates for locks, hinges, metalic fasteners,CC for hold fasts, melamine polishing etc., complete as per detailed drawings.

a) First class TEAK WOOD cum 0.75

b) First class hollock wood synthatic enamel paint. cum 0.35

2 Architrave

Providing and fixing Ist class teak wood wood architrave of size 50mm x 20mm and fixed with nails / wooden plugs including nails, screws, melamine polishing,fire retardant (viper) & anti-termite paint on concealed surfaces, etc. complete as per design and drawing. mtr. 70.00

3 Fixed Glazing

Providing and fixing fixed glazing made of 10mm thick toughned glass fixed to channel in floor & at top in groove made in wooden frame above falseceiling sealed properly with silicon sealent as approved wherever required etc complete as per design and drawing. (straight portion) sqm 55.00

4 Glass Film

Providing and fixing '3M' film on glass surfaces of required design & pattern and as per manufacturers specification (Surface area covered shall be measured and paid for)

Film for pattern etching and per design sqm 75.00

5 Flush Door Shutters

Page 8: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

8

Providing and fixing 35mm thick (shutter thickness excluding laminate / veneer ) both side commercial type flush door shutters (decorative type) core of block board construction and frame of 1st class hardwood phenol bonded, Steam Beech wood lipping 12mm thick on all edges of shutters including brushed steel heavy duty 125mm hinges (4 nos.), PVC buffers, door stopers, melamine polishing to required shade where required etc. all complete as per design and drawing.

a) Both side laminated with 1.0mm thick laminate. sqm 40.00

6 Vision Panel

Providing and fixing vision panel on flush door shutter including cutting of shutter, 6mm thick glass, Steam Beech wood beading from both faces, melamine polishing etc complete as per design and drawing. sqm 0.50

7 Automatic Sliding main Doors

Providing and fixing 45mm thick glazed door shutter comprising of the following.

*

125mm x 45mm saal wood on top & sides rails and 200mm x 45 mm Saal wood on bottom rail as shown and as required.

* 12mm thick toughned glass fixed to rails opening size 1.5x2.4m LS 1.00

8 Frameless Glassed Door Shutters.

a)

Providing and fixing frameless glass swing door made of 10mm thick clear float glass (toughened) with patch fitting of OZONE make sqm 5.00

Page 9: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

9

etc. complete as per design and drawing.( all fitting shall be paid in item no 9 b)

11 Hydraulic Door Closer

Providing & fixing hydraulic door closer concealed type as per approved sample of dpl make, each 8.00

12 Handles & Lock

a)

Providing & fixing Entrance door handle of approved Make, in

brushed steel finish etc complete as per design & drawing & manufacturer specifications. Set 4.00

b)

Providing & fixing wooden door handle of approved Make in

brushed steel finish etc complete as per design & drawing & manufacturer specifications.

i D - Shape Handle. each 4.00 ii C - Shape Handle. each

13 Floor Spring

Providing and fixing in position standard double acting heavy duty floor spring of OZONE make (FS - 7400 + OFS - ACC - TP) with top

pivite to door including 3mm thick brushed steel top cover plate with brass screws complete as approved by the Architect. each 4.00

Total

PART D- PARTITION & PANELING

1 G.I. Frame Work

Page 10: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

10

a)

Providing and fixing GI Frame work (gypsteel - India gypsum) of 48 mm c studs ( 0.55 mm thick, having one flange of 34mm and another flange of 36 mm) for vertical members and U-channels (0.55 mm thick, having equal flanges of 32 mm) for horizontal members placed at 610 mm centre to centre both ways with joints staggered to avoid through joints. The frame work is to be adequately anchored in ceiling and on floor having additional framework of rough wood treated with anti-termite and fire retardent paint for fixing storages, fire extinguishers paintings, switch boxes, door frames etc. complete staright & curved. sqm 25.00

Total

PART E-FALSE CEILING WORKS

1

Mineral Fibre Ceiling ( Regular)

Page 11: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

11

Supplying and fixing of false ceilings at all heights of 600mm x 600mm Mineral Fibre ceiling tiles of dune premiere or equivalent finish tile RH-95 with Tegular/ micro Edge laid on grid of colour White. The framework comprise of main runner spaced at 1200mm centers securely fixed to the structural soffit by approved hangers at 1200mm maximum centers. Hangers (GI wire of 4.0mm dia) to be fixed by approved roof plug, level adjusters and screws etc. The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees (with double stitching) to be interlocked between main runners at 600mm centers to form 1200 x 600 x modules. Cut cross tees longer than 600mm to be supported independently.

600mm x 600mm modules to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200m cross tees. Perimeter trim to be wall angle secured to walls at 450mm maximum centers. (The quoted rate shall be inclusive for making opening for light fixtures, diffusers & AC grills, speakers, sprinklers.) (The quoted rate shall be inclusive of suspenders at all height & extra member required for all openings.) sqm 225.00

2 Gypboard Ceiling

Page 12: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

12

Providing and fixing suspended false ceiling, which includes providing and fixing GI perimeter channels of size 0.55mm thick having one flange of 20mm and another flange of 30mm and a web of 27mm along with perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610mm centers. The suspending gI intermediate channels of size 45mm 0.9mm thick with two flanges of 15mm each from the soffit at 1220mm centers with ceiling angle of width 25mm x10mm x 0.55mm thick fixed to soffit with GI cleat and steel expan-sion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connect-ing clips and in direction perpendicular to the intermediate channel at 457mm centers. 12.5mm tapered edge Gypboard (conforming to IS-2095 - 1982) is then screw fixed to ceiling section with 25mm drywall screws at 230mm centers. Screw fixing is done mechanical-ly either with screw driver or drilling machine with suitable attachment.

Page 13: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

13

Finally the boards are to be jointed and finished so as to have a flush look which includes filling as finishing the tapered and square edges of the boards with jointing compound, paper tape and two coats of primer suitable for Gypboard (as per recom-mended practices of India Gypsum or equivalent), extra framework for electrical fittings, A/C diffusers, and/or any other cutouts, provison for trap doors etc complete including opening to be made for AC grills, light fittings, trap door etc. (The quoted rate shall be inclusive of suspenders at all heihgts.)

a) for horizontal & vertical surfaces sqm 329.87

3

CEILING PELMETS:-Providing and fixing 19mm thick B.W.P pelmets with hard wood lipping and fixied to ceiling with hard wood framing complete including painting.(as indicated in the drawing) (125mm wide) to take vertical blinds. Including 6mm thick back painted ply fixed over hard wood framing upto 450mm high as shown in the dwg. RMT 40.00

Total

PART F-FINISHING WORKS

1 POP Punning (6mm-10mm): Providing and fixing Average 6mm to 10mm thick POP Punning over

cement plaster in line & plumb finished smooth to receive paint. sqm 620.00

Page 14: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

14

2 Plastic Emulsion Paint

a)

Preparation of surfaces and painting walls / ceilings, with plastic emulsion paint approved brand and manufacture to give an even shade three or more coats on new work over a coat of primer.(at all heights & levels) sqm 1250.00

6 WINDOW COVERINGS

a)

Providing and fixing as per approved sample, 100mm wide verticle Fabric Blind of approved make(high quality) complete with hanging channel , sliding and tilting systems in ‘drawn’ position fabric vanes to overlap by minimum of 10mm ( every 1.0 mt running length to have at least 11 Nos 100mm wide fabric vanes )Length of blinds as mentioned in drawings bottom end to be at least 25 mm below horizontal surface. Fabric strip as that of fabric vanes , to be fixed on both side of aluminium top channel. Lower ends of the vanes to be weighed down and tied with each other on both corners, with ball chains. The fabric to be scothgaurd and sanitised (stain repellent) average thickness 0.8 mm, 100 % polyster non woven. Items to be completed in all respects including fixing with brackets onto wall or partition with rawl plugs complete as per the direction of architect Make-.Vista or equivalent.

sqm 70.00

b)

Providing and fixing of Venetian blinds Both side Coated with Blackout Fabric, Coating is of PU. Max. Width 2.50 M; with smooth operating roller rods of approved shade and quality

sqm

Page 15: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

15

c)

Providing and fixing roller blinds Vista/Mascot make and shade with hanging and drawing system including all hardware and fixing complete.

sqm

15.00

Total

PART G-MISCELLANEOUS WORKS

1 Toilet Mirror

Providing and fixing 6mm thick mirror fixed over 12mm BWP grade ply fixed to wall with 40mm dia SS Studs & 25mm away from the wall ine polishing etc. complete as per design and drawing.. sqm 3.50

2 White Board

Providing and fixing white magnetic board of Nova display system (Nova cardinal ) on wall and fixed with all necessary arrangement as per manufacturers specifications including 6mm thick BWP ply & melamine polished wood moulding etc. complete with all accesories of white boards and set of 4 marker pens and duster. sqm 2.50

3 S.S Railing

Providing, fabricating and fixing in position 900 mm high railing comprising of the following

900 mm high 40 mm x 40 mm brushed stainless steel box section of 304 grade vertical member @ approximate 1.5 mtr C/C fixed to MS plate with dash fastener . MS plate to be grouted to cement concrete.

3 nos 12mm dia brushed stainless steel pipe section horizontal member fixed to vertical member .

Page 16: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

16

50mm dia brussed steel pipe hand rail fixed at top of balusters.

including all necessary fixing arrangement, cutting of holes if required and finished the same properly etc complete as shown and as directed.(Rectangular railing) Kg 200.00

TOTAL

Page 17: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

17

7.0 TECHNICAL SPECIFICATIONS

7.1 WOOD WORK :- These specifications shall be read in conjunction with the Drawing and other

contract Documents and other section of this specification which shall be deemed

complimentary with one another. The Contractor shall be responsible for providing all plant,

tools, materials, Labour and all things necessary for the proper execution, completion and

maintenance of the works.

a) Timber :- The moisture content of the timber during manufacture, delivery to site, storage,

storage, site working, assembly installation shall not be more than 10 to 12 percent. Timber shall

be teak wood, soft or hardwood and shall be suitable for the purpose for which it is intended. It

shall be seasoned or Kiln dried, absolutely free from worm holes, large loose or dead Knots or

other defects which would effect strength or usability and shall be flat, straight non-splitting and

dressed on all sides. It shall be matched for colours and graining.

Oak Wood wherever specified in the drawings / schedule of quantities , it is Ist quality of White

oak wood of reasonably straight grains, free of Knots and sap and light vein. wood shall be

stained in required finish.

Hard wood wherever specified in the drawings / schedule of quantities, it is MIRANDI WOOD,

wherever Soft wood is mentioned it shall be KAIL WOOD.

Fixing :-The carpentry timber shall be fixed with nails, spikes, bolts screws, hangers, stirrups,

anchors, ties or any other accessories which are suitable to develop the full strength of the

member which they support to which they are attached, as directed.

All above hardwares for fixing in exterior location shall be as described in specifications.

Page 18: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

18

Carpentry timber where fixed to solid masonry or concrete shall be secured with expansion bolts

or other positive methods of mechanical fastening. MS hold fast grouted in CC block shall be

used to hold the door frames/rough ground.

b) Timber Veneers :- Timber veneer shall be of the timber species shown on drawings. Veneers are

to be kept in sequence as they are being cut from wood and supplied as such to the site for

accurate matching of figuring . The veneer shall be finished as specified and shall be equal or

superior quality to that laid down in IS: 1659 - 1960 or as approved.

c) Plywood’s: All ply wood shall be best /high quality close grained suitable for veneering, painting

or bonding plastic laminate. It shall be resin bonded and BWP grade. Exposed edges shall be

finished with an edge strip of solid teak wood. tongued and grooved and glued , or as detailed.

The plywood of approved brand and manufacture only shall be used in the work. The thickness

shall be in accordance with the drawings /schedule of quantities.

d) Adhesives :- The adhesives used for all wood work shall be FEVICOL OF appropriate Grade.

Manufacturer’s recommendations shall be followed for adhesive other than above required for

any specified / specialized work.

e) Joinery :-Joinery shall be carried out strictly in accordance with the drawings, Where joints are

not specifically indicated recognized forms of joints shall be used. Joinery shall conform to IS

Standards.

Panels shall be rendered flame retardant and to conform to local fire regulations where

specified.

The Contractor shall submit samples of all materials including large samples of veneer for

approval.

All materials pre-fabricated, delivered and assembled shall be in accordance with the approved

sample.

Page 19: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

19

The Contractor shall be responsible for protecting all items of wood-work done by him. the

contractor shall replace at his own expense any damaged work caused through lack of adequate

protection or care in installation or handling .

7.2 MIRROR AND GLASS :-The Contractor shall submit samples of all glasses and mirror types for

approval of Interior Designer /Project Manager. These shall be obtained from the approved

sources only

a) Mirrors :-Mirrors shall be fabricated from best clear plate or float glass of approved quality

(Modi -guard or approved equivalent with clear / bronze finish as show in the drawings

/schedule of quantities and shall match the International Standards.

All fixed panel mirrors shall be 6 mm thick unless otherwise stated having +/- 0.30 mm tolerance

. The edges of mirrors shall be polished and beveled and mitered as per IS. specifications

wherever, it’s indicated in the drawing.

The Etching wherever specified in drawings, shall be done at approved sources as per full-scale

drawing approved by Interior Designer / Project Manager. The etched panel shall be chemically

washed /treated as per specialist specifications to have a permanent dust free surface.

b) Glasses :-All glasses shall be MODI GUARD FLOAT GLASS of specified thickness. The edges shall

be beveled as indicated in drawings and shall be done at approved source.

The Contractor shall be responsible for protecting all mirrors and glasses fixed by him and shall

replaced at his own expense any broken or damaged mirror / glass caused through lack of

adequate protection or care in installation or handling.

Tinted glass - Indian tinted glass in approved colour.

Page 20: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

20

7.3 FURNITURE AND FURNISHINGS :-A Sample of every item of furniture, including its parts shall

be submitted in two sets for approval of Interior Designer / Project Manager before an order is

placed or manufacture commences. Approved samples shall be used as standards of finish and

workmanship.

Figured dimension shall be taken in preference to scaled dimensions in all cases. Before

commencing any work the contractor shall verify all measurements on the site.

All joints shall be standard mortise and tennon dowel, dovetail cross halved, mitered tongue and

grooved or rebated. Nailed butt joints will not be permitted. Where mortise and tennon joints are

used tennons shall fit the mortise exactly. Lap joints with glue shall be permitted in wood skirting.

Where metal legs, frames and the like are used, these shall be welded, brazed bolted or riveted as

required, and on finished surface welding, brazing, and riveting shall be grounded so that no

evidence of this is apparent on the final finish of the metal.

All legs of case or Cabinet furniture, whether of wood or metal shall be equipped with nylon

glides or castors unless otherwise shown on the drawings.

The finishes of furniture shall be fully in accordance with the drawings and schedule of quantities.

Where the upholstery fabric is patterned no upholstery fabrication is to commence until the

contractor has received clear instructions concerning the direction of the pattern and the method

of its joining. Upholstery will be of first class workmanship with webbing, no-sag springs, coiled

springs, padding filling as specified. Covering fabrics will be sewn ,tufted, and corded as shown on

the drawings or schedule of quantity.

Page 21: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

21

Cushion vents shall be made in the back or underside of all seat cushions in sufficient number to

allow air to escape easily and prevent torn seams.

The Contractor shall protect and guard all fixed items and loose items of furniture, fixtures,

fittings and all other furnishing from fire, damp, theft or any other damage until the date of hand

over the completed works.

7.4 LATEX FOAM RUBBER :-Latex foam rubber used in the work shall be ISI marked and shall

conform to IS 1741-1960. The Grade of the foam should be used as mentioned below :

a) Grade B C or D shall be used in the back cushion and arms.

b) Grade D, E or F shall be used in the seat cushion of the furniture’s.

The Actual length and width of a latex foam rubber product should be greater than the nominal

dimension by a small amount in order to admit of the foam rubber being slightly compressed by

a cover made to the nominal dimensions.

7.4 FALSE CEILING :-The Plaster of paris used in the work shall be of the calcium sulfate semi-

hydrate variety. It shall be of finest quality and shall not too quick setting. The initial setting time

shall not be less than 13 minutes.

False ceiling work shall be executed in accordance with relevant IS specification . G I framing

shall be erected as described in schedule of quantities and fixed with GI metal mesh of approved

quality weighing .75 Kg/ Sqm. M.S. hangers shall be fixed on the frame of false ceiling and

approved GI dash fasteners fixed to RCC beam / slab as directed by Project Manager . Main

members of the Framing shall be placed at 750 mm centre to centres and cross members at 375

mm centres shall be fixed to main members. All frame work and metal mesh shall be fixed with

self tapping screws.

Page 22: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

22

The POP thickness shall not be less than 10 mm and shall be finished to true line and level.

Proper template / mould shall be made to make and finish cornice / moulding profile as per

drawings. A sample of each cornice / moulding profile shall be got approved from Interior

Designer/ Project Manager. All POP surface shall be painted and finished with acrylic emulsion

paint and MS hangers with approved steel primer and synthetic enamel paint.

7.6 PAINTING :

a) Textured Finish The wall / wooden surface wherever specified in the drawings / schedule of

quantities shall be finished with approved textured finish. The specifications shall be as per

manufacturer’s recommendations for the approved products. The sample of shade and textured

finish shall be as approved by Interior Designer.

b) Painting All paints / polishing material (Acrylic emulsion paint, Duco paint, Melamine polish)

shall be of approved make and manufacturers and shade / finish. the surface to be treated shall

be thoroughly cleaned and dusted before painting / polishing. The surface shall be prepared and

got approved by Project Manager before application of primer. The paint / polish shall be

applied with brush /roller / spray as required and directed by Project Manager. The surface of

finishing shall present a flat velvety smooth finish. If necessary more coats shall be applied till

the surface presents uniform appearance. After painting work, doors, window in the area shall

be kept open to provide good ventilation and to ensure proper drying.

7.7 FLOORING All flooring shall be laid to the best practice Known to the trade. The flooring shall

be laid to the level except where slopes, offsets / depressions are called for on the drawings.

Particulars care shall be excersied to ensure that all flooring , skirting and dado are perfectly

matched for colour and finish. The contractor shall furnish for approval by the Interior Designer

Samples of each type of floor finish.

Page 23: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

23

a) Granite/Tile/ Flooring and Skirting : Stone/Tile shall be the best as per the specification

(Diamond-polish ) approved by the Interior Designer and a sample piece should be kept in the

office of the Project Manager. The quality shall be uniform and it shall be hard and free from any

dis

coloration’s, cracks ,veins of foreign material or any other defects. The slabs shall be machine

cut true to the shape and size and are pre-polished. The Marble shall be bedded in cement

mortar backing covering the full area of the marble. Joints between slabs shall be hair fine and

filled with coloured cement to match the slab . The Stone Floor / skirting shall be finally buffed

with polishing felt and cleaned with diluted oxalic acid wash.

The stone slabs shall be machine cut true to the shape and size and machine polished. care shall

be taken to cut the slabs so as to provide a pattern as indicated.

Stone slabs for wall lining and dados shall be machine polished edges. The wall shall be lined

with the marble in courses as indicated and arranged in pattern as per detailed drawings. The

marble shall be bedded in cement mortar backing covering the full area. The wall surface shall

be cleaned from all dirt, mortar droppings etc. before fixing stone.

Page 24: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

24

LIST OF APPROVED MAKES

The following is the list of approved makes of materials mentioned below.

The contractor shall produce samples, before procurement of the materials, for approval of the Interior Designer/Project Managers. Sample of best quality natural stone shall be submitted to the Project Managers within 3 days of submitting the quote.

Where more than one manufacturer is listed, the names are given in the order of preference. The contractor shall quote the rates for the various items of work based on the materials of first preference after ascertaining the availability, delivery schedule of the same. Unless the contractor stipulates in his tender, it shall be presumed that the rates quoted are for material of first preference only.

In the event, the contractor is permitted to use the material of lower preference because of valid reasons, than the contract rates for the relevant items of work shall be suitably adjusted on the basis of variation in prices of the materials of first preference and those actually used. If the prices of the materials used are higher than the material of first preference, the owner shall not be liable to make any enhanced payment for the affected items of work on this account.

In respect of materials for which approved makes are not specified below, these will be of makes to be decided by Interior Designer / Project Managers and as per samples getting approved.

MATERIAL MAKE/BRAND NAME

Adhesive For wood –Fevicol – SH

Poly sulphide sealant Birla, J.K.

Water proofing compound Cico or approved equivalent

Hardware Doorma / Hafflle / Hettich or approved equivalent

Laminated particle Anchor, Novapan. Board (phenol bonded)

Locks Doorset/ Godrej / Hettich / Hafele / Dorma

Epoxy Fosroc, Sika Silicon sealant Dow corning, GE or equivalent

Paints Sherwin Williams, Asian, ICI , Nerolac

POP Shri Ram, Birla, Sakarni, Gypsum India

Putty JK / Birla or equivalent.

Polyurethane foam U-foam (density 45 +) or equivalent (ISI marked)

Screw Pentagon , Nettle fold.

Wood preservatives Asian paint , J&N , Shalimar , Rajdoot, Berger paints, Salignum.

Page 25: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

25

Commercial ply Archidply, Sonear, Legend, Greenply

Water proof ply Archidply, Sonear, Legend, Greenply

Veneer Archidply, Sonear, Greenlam Decowood, Legend

Laminate Archidply, Sonear, Green Mika, Merino

Door Frames Archidply, Green Mikasa, Sonear Anchor Fasteners Hilti, Fischer

Glass Saint Gobin, Modifloat or approved equivalent

Mirror Saint Gobin, Modi guard or approved equivalent

Calcium Silicate Board Hi Lux (Ramco Industries Ltd).or equivalent Silicon

Sealant Asian or equivalent

Gypsum board India Gypsum LTD. Melamine

Asian or approved equivalent

Ant termite treatment ASCOU ( for wood surfaces)

Fire Retardant Paint Navair (viper)

Fire Doors Sukri / Promat / D.S. DOORS

Furniture Handles Doorset / Hettich / Hafele / Dorma or approved equivalent

Hinges Doorset / Hettich / Hafele / Dorma or approved equivalent

False ceiling member Gyp steel of India gypsum LTD. a)

Perimeter b) Ceiling section c) Inter mediate

Flush door shutter Archidply, Sonear, Legend, Merino or approved equivalent

MDF NUWUD / Green Panelmax / Duratuff Soft Board Sitatex

Door closer Dorma / Hettich or approved equivalent

Tile Grout Bal Endura or approved equivalent

Glass Mosaic Bissaza/ Palladio or approved equivalent

Page 26: BILL OF QUANTITIES - INTERIOR WORKS ADMIN BLOCK ...Technical Specification Interior Works 3 Three coats of tapecrete - ( first layer of tapecrete to be @0.253kg/sqm, the second & third

Technical Specification Interior Works

26

White Cement Birla

Wall Paper X-Select or approved equivalent

Tile Nitco & Bainco or approved equivalent

Blind Hunter Douglas/Macdecor or equivalent

Gray Cement Vikram, ACC White Cement Birla White, J.K Marble Sealer Laticrete, Aquamix Insulation Wool U.F. Twiga / Crown / Lloyd Wooden Flooring Pergo PU Polish ICEA