The new BIASI b i thermic range.
BINOVA
-
BINOVA is the new BIASI wall hung boiler bithermic range for central heating and domestic hot water. It is available open and sealed chamber with the only 24 kW output. Easy to install and to maintain, BINOVA is the boiler suitable for replacement of existing boilers and for new dwellings.An innovative digital control panel has been studied to have an easier user interface and a more comprehensive list of informa-tion and procedures of programming dedicated to the installer.The innovative design and the compact dimensions of this model makes BINOVA suitable in different locations.
BINOVA
WA
LL
HU
NG
BO
ILE
R
CONTROL PANEL
INFO MENU
SYSTEM FILLING
By pressing the keys 3 and 5 at the same time, BINOVA enters the INFO menu, where it is possible to visualize the parameters. To scroll the list press the key 3 or 4. Here follows the list of main parameters in the order they appear:
BINOVA gives the indication when it is better to fill before the boiler locks:
Key to adjust DHW temperature
1
5
3
2 4
Key to adjust CH temperature
Winter / Summer / Stand by modality
The system needs to be filled.
To visualize the pressure in the system, press the key 3 and 5 together.
BINOVA remembers to the user when yearly mainte-nance has to be done and the list of the last ten faults of the boiler.
= 1,3 bar
System pressure J00 / value
External temperature (With external sensor connected) J01 / value
K value for thermoregulation J02 / value
K offset value J03 / value
Central heating temperature set J04 / value
CH flow temperature J05 / value
DHW temperature set J07 / value
The value of each parameter appears alternatively with the number of parameter it is visualized.
The pressure is a bit low, the icon flashes to suggest the filling;
The boiler is locked: the system must be filled till the icon stop flashing.
The right value of pressure is between 1 and 1,5 bar.
Boiler in winter set.
Boiler in summer set.
DHW request.
CH request from room thermostat.
-
WA
LL
HU
NG
BO
ILE
R
The BIASI simplicity
BINOVA is an high efficiency boiler.The modulation of the output ensures a reduction of gas con-sumption and the best suitability to the different central heat-ing and domestic hot water requests. The same bithermic heat exchanger produces DHW, ensuring the comfort thanks to the DHW flow switch and to the temperature sensor on the DHW outlet.
EFFICIENCY HYDRAULIC SCHEME
BINOVA has the same compact dimensions of the whole tradition-
al BIASI range. This ensures easy replacement and installation.
To make easier the installation, BINOVA has the cable for the sup-
ply line as standard and the possibility to connect the external
sensor and the remote control.
DIMENSIONS
★★★ Central heating (Dir. Rend. 92/42)
Bithermic heat exchangerBurnerDetection and ignition elec-trodeDHW flow switchGas valveExpansion vessel
1.2.3.
4.5.6.
Pressure readerPumpBy passCH temperature sensor and safety thermostatDHW temperature sensor
7.8.9.10.
11.
1
23
45 6
7
8
9
10
11
HYDRAULIC AND FLUE CONNECTION
Sealed chamber
A Coaxial flue /air (60/100 mm)
B Twin Flue pipe (80 mm)
C Twin Air pipe (80 mm)
Open chamber
A Flue axis
Sealed – Open chamber
D Boiler axis
E CH flow
F DHW outlet
G GAS
H DHW inlet
I CH return
Sealed chamber versionOpen chamber version
400
65645265
703
702
43
200
G
A
D
327
188
E
FH
I
115
98
G
E---FH---I
15 368 16
12 A
400
65645265
703
702
125
43
200
B
G
A
D
C
327
201
237C
A --- B
E
FH
I
115
98
G
E --- FH --- I
15
93150
368 16
12
-
BINOVA 24A 24S
Nominal heat output kW 21,3 23,8
Minimum heat output kW 9,4 9,9
Measured efficiency at nominal heat input/ at 30% load % 89,7 / 88,3 92,8 / 91,1
Efficiency (Dir.Rend. 92/42 CEE) N° ★★ ★★★
Central heating Minimum / Maximum temperature ° C 38 / 85 38 / 85
DHW Minimum / Maximum temperature ° C 35 / 60 35 / 60
Minimum / Maximum central heating pressure bar 0,3 / 3 0,3 / 3
Minimum / Maximum DHW pressure bar 0,3 / 10 0,3 / 10
Expansion vessel capacity l 6 6
Useful head at the flow rate of 1000 l/h bar 0,3 0,32
Max flow rate Δt = 25 K / Δt = 30 K l/min 12,1 / 10,1 13,5 / 11,3
Electrical protection degree IP X4D X5D
Nominal voltage V 230 230
Weight kg 28,5 30,5
Maximum Ø 60/100 – Ø 80/125 coaxial flue length m / 3
Losses due to coaxial 90°- 45° elbows (Ø 60/100 and Ø 80/125) m / 1 / 0,50
Maximum Ø 80/80 twin flue length m / 15
Losses due to twin 90°- 45° elbows (Ø 80) m / 1,65 / 0,90
Smoke production at nominal / minimum heat input** kg/s 0,0178 / 0,0169 0,0147 / 0,0159
Air consumption at nominal / minimum heat input** kg/s 0,0174 / 0,0166 0,0142 / 0,0157
Flue temperature at nominal / minimum heat input** °C 106 / 88 120 / 104
Thermal loss to the ambient through the case with burner on* % n.a. 0,8
Chimney thermal loss with burner on* % n.a. 5,8
Chimney thermal loss with burner off* % n.a. 0,2
Nominal / minimum CO2** % 5,5 / 2,6 7,3 / 2,9
Nominal / minimum O2** % 11,1 / 16,3 7,9 / 15,8
Cod
. 482
3.03
16.0
000
- 50
0010
11 -
Rev
. 00
- U
NIG
RA
F sn
c (V
R)
WA
LL
HU
NG
BO
ILE
R TECHNICAL DATA
This catalogue replaces the previous one.
Our policy in one of continued improvement in both design and performance of our products BSG Caldaie a Gas S.p.A. therefore reserves the right to alter specifications without prior notice in accordance with product design policy and keeping with market requirements.
* Measured figures with 1 m coaxial flue pipe Ø 60/100 for sealed chamber boilers and 1 m chimney for open chamber boilers** Measured figures with split pipes Ø 80 mm 1 m flue + 1 m air (G20) for sealed chamber boilers and 1 m chimney for open chamber boilers
FLUE KIT
Coaxial flue kit (60/100 mm) Roof kit (80/125 mm) Twin pipes (80/80 mm)
L
Ø 125
For each kit there are available elbows (90°-45°) and extensions. The maximum length for each model and expulsion type are on the table above.
Sede commerciale, amministrativa, stabilimento e assistenza tecnica:
33170 PORDENONE (Italy) via Pravolton, 1/b
Tel. +39 0434.238311 - Fax 0434.238312
Sede commerciale Fax +39 0434.238400
Assistenza tecnica Fax +39 0434.238387
BSG Caldaie a Gas S.p.A.
Sede Legale: via Leopoldo Biasi, 1
37135 VERONA www.biasi.it