biomech of space closure-ortho / orthodontic courses by indian dental academy
TRANSCRIPT
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure INDIAN DENTAL
ACADEMYLeader in continuing dental education
www.indiandentalacademy.com
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure Introduction
Every object or free body has one point on which it can be perfectly balanced. This point is known as the center of gravityIn a restrained body, such as a tooth, a point analogous to the center of gravity is used; this is called the center of resistance.
By definition, a force with a line of action passing through the center of resistance produces translation.
The center of resistance of a single-rooted tooth is on the long axis of the tooth, probably between one third and one half of the root length apical to the alveolar crest. For a multirooted tooth, the center of resistance is probably between the roots, 1 or 2 mm apical to the furcation.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Relevance of the center of resistance
First, the position of the center of resistance varies with root lengthThe tooth movement resulting from a force delivered at the bracket depends upon the distance of the line of action of the force from the center of resistance; Identical forces applied to teeth with different root lengths can have different effects.
A second important point is that the center of resistance varies with alveolar bone height. The movement of teeth in adults with alveolar bone loss will be different than in adolescents.
Smith and Burstone AJO-DO 1984www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The M/F ratio is the relationship between the applied force and the counterbalancing coupleThe type of movement is dictated by the moment to force ratio (M/F) generated by the appliance at the attachments. Typically, M/F ratios of approximately 7:1 millimeters result in controlled tipping, 10:1 millimeters result in translational movements, and values of 12:1 millimeters or greater accomplish root movement.
This has important implications. It is the ratio between the applied couple and force that determines the type of
tooth movement, not the absolute magnitudes.www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
These ratios are based on the assumptions that
the root lengths are 12 millimeters,
the distance from the bracket slot to the alveolar crest is five millimeters,
the alveolar bone condition is normal,
the axial inclination of the teeth is normal,
and the center of resistance is located apically a distance .40 times the root
length when measured from the alveolar crest to the apex.
Manhartsberger, Morton, Charles J Burstone Angle 1989www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Force systems can be defined as statically determinate when the moments and forces can be readily determined, measured and evaluated.Statically indeterminate systems are too complex for precisely determining all the forces and moments in the equilibrium.
Usually only the direction of the net moment and the appropriate net force levels can be determined.
Determinate systems in orthodontics are those in which a couple is created in one end of an attachment with only a force and not a couple at the other end .e.g. a spring which is inserted to a tube or bracket at one end and tied at the other end to only one point.
STATICALLY DETERMINATE AND INDETERMINATE SYSTEMS
WILLIAM R. PROFFIT, HENRY W. FIELDSwww.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Orthodontic space closure should be individually tailored based on the diagnosis and treatment plan.
The selection of any treatment whether a particular technique, stage spring or appliance designs should be based on the desired tooth movement.
Orthodontic space closure
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
A well-designed appliance should exhibit three general characteristics:
(1) It should deliver a known, relatively constant moment-to-force ratio over a long range of activation;
(2) the resultant motion of the active unit (teeth being moved) occurs about a predictable center of rotation; and
(3) the force system at the reactive unit (anchor teeth) should be known and controllable.
Braun and Marcotte AJO-DO 1998www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
(1) Differential space closure..
(2) Minimum patient cooperation.
(3) Axial inclination control
(4) Control of rotations and arch width.
(5) Optimum biologic response.
(6) Operator convenience.
The six goals to be considered for any universal method of space closure:
To achieve controlled extraction site closure, the appliance used must
deliver definable force systems regulated by the clinician and not produce
closure in some ambiguous, indeterminate way. Only when force systems
are definable are the dental movements predictable and treatment outcomes
forecast able with confidence.
CHARLES J BURSTONE AJO-DO 1982www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Space closure should result in upright well aligned teeth with parallel
roots and parallel occlusal plane.
Therefore some degree of bodily or even root movement is required.
Idealized objective of space closure:
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Amount of crowding:in cases of severe crowding, anchorage
control is very important to maintain the extraction space for relieving the anterior crowding
Anchorageusing the same mechanics for different
anchorage needs is very important. Traditional anchorage methods like lip bumpers, headgears, transpalatal arches may be utilized but non compliance methods for anchorage control based on biomechanics can also be used.
DETERMINANTS OF SPACE CLOSURE
NANDA& KULHBERG
The main factors which determine the tooth movement during space closure are:
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Axial inclination of canines
the same force /and or moment applied to teeth with different axial inclinations will result in different types of tooth movement.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Midline discrepancies and left right symmetry.Midline discrepancies should be corrected as early as
possible in treatment as it allows the remaining space closure to be completed symmetrically. Using asymmetric mechanics can cause in unilateral anchorage loss, skewing of the dental arches, or unilateral vertical forces.
Vertical dimensionControl of vertical dimension is essential in space closure.
Undesired vertical extrusive forces on the posterior teeth can result in increased LAFH, increased interlabial gap, and excessive gingival display. Class II elastics may potentate this problem.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
It is the ability to prevent tooth movement of one group of teeth while moving another group of teeth.
The problem of anchorage is rooted in Newton’s third law:For every action there is an equal and opposite reaction.
Several anchorage control methods have been developed over the last century.
The contributions of Angle, Begg , Case, Tweed and others have provided a foundation for modern orthodontic mechano therapy.
Although each of them advocated different methods and philosophies, a review of their work shows a lot of similarities.
FUNDAMENTAL CONCEPTS AND CLINICAL METHODS OF ANCHORAGE CONTROL
ANDREW KUHLBERG, DEREK PRIEBE: SEMIN ORTHOD 2001
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
In 1907, EH Angle advocated 5 types of anchorage control.
Occipital anchorage depended on the use of extra oral anchorage
Intermaxillary anchorage included the use of elastics.
The remaining three were dental anchorage:
Simple, reciprocal and stationary methods for dental anchorage.
Calvin S Case also advocated stationary anchorage methods despite his differences with Angle’s school of thought.
He also described the use of extra oral and intermaxillary anchorage as well as the prerequisite that resistance to tipping movements was requisite for intra arch control.
Case advocated the use of soldered firm attachment of anchorage teeth to one another to maintain their upright positions.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
20 years later Charles Tweed advocated similar techniques. His method of anchorage preparation against unwanted tipping and extrusive side effects were a series of tip back bends to anchor the teeth like tent stakes to resist vertical and anterior posterior displacement during intermaxillary traction.
Although Tweed said his methods of anchorage preparation were more mechanical than biological, the tip back bends were a further refinement of Angle’s stationary anchorage methods.
Despite his adherence to the differential force theory, PR Begg also used a similar technique for anchorage control. His tip back bend to maintain the anteroposterior position of teeth to effect preferential movement of teeth was also supplemented by initially tipping the teeth to be retracted followed by up righting them.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
A ANCHORAGE
This category describes the critical maintenance of the posterior tooth position.
75% or more of the extraction space is needed for anterior retraction.
Group A arches tend to be of two types:
B ANCHORAGE
This category describes relatively symmetric space closure with equal movement of the anterior and posterior teeth to close the space.
This is the least difficult of the space closures.
C ANCHORAGE
This category describes non critical anchorage, where 75% or more of the space closure is achieved through mesial movement of the posterior segment; this could also be described as critical anterior anchorage.
Anchorage can be classified as:
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Dividing the extraction space into quarters aids in visualizing the anchorage classification
NANDA& KULHBERGwww.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The basic techniques for anchorage control basically rely on three fundamental similarities:
extra oral forces on the anchorage unitintermaxillary elasticsTipping tooth movement while simultaneously discouraging tipping of anchorage teeth.
Patient compliance is mandatory for the first two techniques.Without co operation control of tooth movement is lost and the results may be
compromised.
The way a tooth moves is dependent on the nature of the force systems that act on it. This includes the actual force and moments at the bracket, the force distribution around the periodontal ligament,.
The force distribution is a function of the centre of rotation.
ANCHORAGE FROM A BIOMECHANICAL PRESPECTIVE:
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure CONTROLLED TIPPING:
Is tooth movement with the center of rotation at the root apex. The resultant forces are distributed at the marginal portion of the periodontal ligamentThe M/F ratio is approx. 7/1TRANSLATION or bodily movement maintains the axial inclination of the tooth and the centre of rotation is at infinity. The resultant force on the PDL is equally distributed along the pressure side of the alveolar structures.The M/F ratio is approx. 10/1ROOT MOVEMENT or displacement of the tooth apex while the crown remains stationary occurs with a M/F ratio of approx. 12/1 here forces tend to be concentrated on the apical third of the root.
Within these basics lie the fundamental principles of anchorage control.www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
What happens when a high M/F ratio is applied to the anchor teeth?
An applied force causes uncontrolled tipping while the applied moment counteracts the tipping effect of the force. This applied moment acts in the opposite direction and moves the roots to the extraction site and if the magnitude further increases, tips the crown distally
A low M/F ratio produces tipping with the crown moment noticeably greater
How can these forces be produced clinically?
If M/F ratio of posteriors> M/F ratio of the anteriors there must be either unequal forces or unequal moments
Unequal forces can be produced by headgear, J hook headgear, and intermaxillary elastics. Unfortunately this is co operation dependant
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The ideal for system for a group A space closure would have only a force system resulting in anterior translation and no forces acting on the posterior teeth thereby maintaining perfect anchorage control.
This is possible only with extraoral anchorage or if the opposite arch is used as anchorage.Two approaches:
differential forcesdifferential moment to force ratios
group A requires the posterior segment to have higher M/F ratios (when the force is reduced M/F is increased) and the anterior segment to have a decrease in M/F ratios.
BIOMECHANICAL STRATEGIES FOR DIFFERENTIAL SPACE CLOSURE:
NANDA& KULHBERGwww.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
the law of static equilibrium ensures that within a single intra arch appliance the mesiodistal forces must be equal,
thus forces can be increased or decreased only by utilizing extra oral forces or the opposite arch via intramaxillary elastics.
These are compliance dependent methods which also have additional side effects.
Differential forces
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Increasing the posterior moment causes root movement M/F>12/1 while decreasing the anterior moment causes a tipping type of moment M/F ~7/1
If the posterior moment were large enough the M/F ratio would approach infinity consistent with the application of a pure couple on the posterior segment. this would result in rotational tooth movement about the center of resistance of the anchor teeth moving the crowns distally and increasing the size of the extraction space.
differential moment to force ratios
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Unequal moments must be balanced by a third moment . This couple is a pair of vertical forces. intrusive to the anterior and extrusive to the posterior. The magnitude is dependent on the difference of the moments acting on the teeth and the distance between the anterior and posterior teeth.No matter what the strategy some biomechanical side effects will occur.The difficulty of group C anchorage mirrors that of group A. The difference is that the anterior teeth are the effective anchor unit. therefore the anterior moment is of greater magnitude and the vertical side effect is an extrusive force on the anterior teeth.
Differential moments are not without side effects:
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Optimal force is the idea that there is a force level that will promote the most efficient treatment without untoward side effects.The true mechanical parameter in tooth movement is not the magnitude of the force per se, but rather the magnitude of the stress generated by the appliance in the surrounding periodontium. Stress is defined as force per unit area (for example, gm/cm2) and strain is the unit deformation that occurs in the tissue as a result of the stress.
BIOLOGIC VARIABLES IN ANCHORAGE CONTROL AND DIFFRENTIAL SPACE CLOSURE:
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
. Possible hypotheses of the relationship between stress magnitude and the rate of tooth movement are graphically represented.
Quinn & Yoshikawa AJO-DO 1998www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Hypothesis 1 shows a constant relationship between rate of movement and stress. The rate of movement does not increase as the stress level is increased. The clinician operating under this assumption controls anchorage only through interarch and/or extraoral mechanics. To place more teeth into the anchorage unit or extract teeth in a more anterior position in the arch does not affect the final tooth position.
HYPOTHESES OF THE STRESS-MOVEMENT RELATIONSHIP (Quinn and Yoshikawa)
If elastics are used for retraction, only one size is necessary. Loop designs are not critical and can be simple and uncomplicated by helices. Intrarch mechanics cannot be altered to change final tooth position.
An extraction site, regardless of where it lies in the arch, is always evenly closed by retraction of the teeth anterior to it and protraction of the teeth posterior to it. The periodontium is sensitive only to force direction and not to force or stress magnitude.
stress
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure Hypothesis 2 is more complex.
The relationship here calls for a linear increase in the rate of tooth movement as the stress increases.
Operating under this hypothesis, the clinician would, in order to shorten treatment time, use appliances that generated the highest stress values
In this system intraarch anchorage could be manipulated by adding teeth (second molars) to the anchorage unit or moving the extraction site— for example, second versus first premolars.
This would distribute the stress over a larger root surface, lowering the local stresses and slowing the rate of tooth movement. Arch wires designed for space closure would be fabricated from large, cross-section steel wire with closing loops activated to generate large stresses. The appliance that delivered the highest stresses would close extraction sites most rapidly.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
depicts a relationship in which increasing stress causes the rate of movement to increase to a maximum. Once this optimal level is reached, additional stress causes the rate of movement to decline This hypothesis was originally proposed by Smith and Storey.Some clinicians assume the validity of the latter part of the curve in this hypothesis where light forces move teeth "optimally" and an increase of stress slows movement.
Hypothesis 3
These clinicians use light forces, for example, to retract canines and prevent anchorage loss while using heavy forces to protract posterior teeth and "anchor" the canines. The orthodontist who operates under this hypothesis theoretically has a great deal of control over anchorage and final tooth position without resorting to extraoral or interarch mechanics.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure Hypothesis 4
is a composite of some of the foregoing concepts.
Here the relationship of rate of movement and stress magnitude is linear up to a point; after this point an increase in stress causes no appreciable increase in tooth movement. Because the rate of movement is dependent on changes in stress, anchorage can be controlled within the arch. Change of extraction patterns, addition of teeth to the anchorage unit, and modification of intraarch retraction mechanisms to fit the anchorage requirements are all effective means to determine the final tooth position.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
For example, operating under this hypothesis, a clinician could enhance canine retraction by
(1) extracting first premolar teeth instead of second premolars,
(2) incorporating second molars into the posterior segment,
(3) adjusting the stress delivered by the retraction mechanism so that the stress level at the canine would coincide with the maximal rate of movement. The stress on the posterior teeth would be distributed over a greater root area, lowering the local stresses and producing a rate of movement less than maximal.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
None of the studies reviewed by Quinn and Yoshikawa support hypothesis 1. All of the results show that, to varying extents, changing the mean stress magnitude will produce changes in the rate of tooth movement
Hypothesis 2 is difficult to disprove because most studies used only two force magnitudes and were unable to describe the behavior of the curve as the stress reached higher levels. Boester and Johnston did demonstrate, however, that in their system forces above 140 gm produced no measurable increase in tooth movement. This study, along with that of Hixon et al. which suggested a 300-gm plateau, casts serious doubts on the validity of the continuing linear relationship proposed in hypothesis
EVALUATION OF HYPOTHESES
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure Hypothesis 3, the original Smith and Storey proposal, can no longer be
considered viable in light of subsequent data.
•A more rigorous analysis of their report shows that their data did not justify their conclusions. The canine moved further than the molar at both the high and low force levels and there is no evidence for the rate of movement to suddenly reverse as the stress levels increase past a certain "optimum" value.
• Furthermore, in all the canine retraction experiments, the rate of canine movement was greater than that of the molar segment.
• Because of its smaller root surface, the mean stresses on the canine can be assumed to be higher than those on the posterior unit.
•At the stress levels evaluated in these experiments then, an increase in stress appeared to cause an increase in the rate of movement. The available literature suggests that hypothesis 3 may not be an accurate representation of the data.www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
All studies reviewed support the idea that increasing mean stress produces a higher rate of tooth movement. Both Smith and Storey and Andreasen and Zanier demonstrated greater displacement of the posterior teeth as the force level was increased. This finding is consistent with the hypothesis since the molar segment, under less stress because the force is distributed over a larger area, would be on the ascending portion of the curve and would move at a greater rate when the stress level was increased.
The evidence for hypothesis 4 is more compelling.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Interestingly, neither study provided evidence of a statistically significant difference in canine movement at the two force levels. This might indicate that the canine was moving at a near maximum rate at the lower force and that increasing the force did not increase the rate of movement. These data, along with those of Boester and Johnston, Hixon et al. and Burstone and Groves, provide evidence that beyond a certain stress level increasing stress no longer alters the rate of tooth movement.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
If hypothesis 4 with a clinically useful slope and a plateau in the 100 to 200 gm range is thought to be a valid model, there are two clinical strategies that would maximize anchorage within the arches.
The first is to lower the stress delivered to the posterior teeth. This can be done by increasing the root surface area,
either by incorporation of second molars into the anchorage unit or by making extractions more anteriorly in the arch. The decrease in stress obtained by increasing the root surface area of the posterior teeth will slow their rate of movement and allow more canine retraction. The same rationale makes extraction of second premolar teeth a logical choice in minimum anchorage cases.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The second strategy for minimizing anchorage loss is to use an appliance system that can deliver relatively continuous stresses in the range described earlier.
Excessive stress produces an increase in the rate of movement of posterior teeth without increasing retraction of anterior teeth.
Appliances that have a high load-deflection rate are unable to achieve a difference in the rate of tooth movement.
Low load deflection-rate mechanics, on the other hand, can maintain stresses in the desired range and maximize the difference in the rate of movement.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The force system of an orthodontic appliance acts in all three planes and determines the type of tooth movement.ALPHA MOMENTThis is the moment acting on the anterior teeth (also called anterior torque)BETA MOMENTThis is the moment acting on the posterior teeth. Tip back bends placed mesial to the molars produce an increased beta moment
DIFFERENTIAL FORCE SYSTEMS-VARIABLE MOMENTS AND FORCES
The components of a force system for a space closure from a Sagittal view are:
NANDA& KULHBERGwww.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
HORIZONTAL FORCESThese are the mesio-distal forces acting on the teeth which are equal to each other.
VERTICAL FORCESThese are the extrusive intrusive forces generated because of the unequal moments. When the beta moment is greater, a intrusive forces act on the anterior teeth. And while alpha moment is greater an extrusive force acts on the anteriors while an intrusive force acts on the posteriors.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure Center of resistance of anterior teeth during retraction
The location of the center of resistance of various consolidated units of the
maxillary anterior dentition was studied using a dry human skull when
subject to retrusive forces.
The units studied consisted of
(a) two central incisors,
(b) four incisors, and
(c) six anterior teeth.
The laser reflection technique and the holographic interferometric
technique were employed to measure the displacement of the dentition
to the applied forces.
Vanden Bulcke, Dermaut, Sachdeva, and Burstone AJO-DO 1998www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
1. For an anterior segment comprising two central incisors, the center of resistance was located on a projection line parallel to the
midsagittal plane on a point situated at the distal half of the canines.
2. For an anterior segment that included the four incisors, the center of resistance was situated on a projection line perpendicular to the occlusal plane between the canines and first premolars.
3. For a rigid anterior segment that included the six anterior teeth, the center of resistance was situated on a projection line perpendicular to the occlusal plane distal to the first premolar.
Results:
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
4. The centers of resistance of the anterior segments incorporating two or four anterior teeth were within ± 2 mm of each other. However, inclusion of the canines in the anterior segment resulted in the center of resistance moving distally by approximately one premolar width (7 mm). This effect may have been the result of the resistance of bony structures at the level of the canines and some bending of the maxillary complex as was observed on the holograms.
5. No appreciable shift in the location of the centers of resistance of the various segments studied was detected as varying magnitudes of retractive force were applied.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure METHODS OF CANINE RETRACTION:
Friction Frictionless ( PG spring, Burstone T loop, Ricketts)
METHODS OF ENMASSE RETRACTION:OF FOUR INCISORS
FrictionFrictionless
PG retraction spring, Utility arch, Omega Loop archwire
ExtraoralHeadgears
OF SIX ANTERIORSClosing loop archwireBurstone T loop continuous archwireOpus loop
INTRUSION AND RERACTION OF FOUR INCISORSBurstone’s three piece intrusion archRickets retraction and intrusion utility arch
SIMULTANEOUS INTRUSION AND RETRACTION OF SIX ANTERIORS K-sir arch www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The most significant distinction between the mechanics of standard edgewise and preadjusted appliances was observed during space closure.
With standard edgewise appliances, rectangular archwires did not effectively slide through the posterior bracket slots because of the 1st-, 2nd-, and 3rd-order bends.
The orthodontist normally used a closing loop arch, which was activated in the office by opening the closing loop and moving the archwire through the posterior bracket slots
- RICHARD P. McLAUGHLIN, JOHN C. BENNETT, JCO 1998www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The level bracket slot alignment of the new appliances allowed
archwires, for the first time, to move more effectively through the
posterior slots when the patient was not in the office.
As a result, many orthodontists discontinued use of closing loops and
began using various forms of sliding mechanics— for example,
placing hooks in the anterior sections of straight archwires and tying
elastics or springs to them from molar brackets
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Closing loop arches had several disadvantages:1. Extra wire-bending time2. Poor sliding mechanics3. Tendency to run out of space for activation (after two or three activations, the omega loop contacted the molar bracket and the archwire had to be adjusted or remade)4. High initial force levels
They also had advantages:1. Precise control of the amount of loop activation (often as little as 1mm), limiting the amount of initial tipping2. Adequate rebound time for uprighting between appointments (with minimal activations, loops closed quickly with little tipping)
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure Sliding mechanics had these advantages:
1. Minimal wire-bending time2. More efficient sliding of archwires through posterior bracket slots3. Sufficient space for activationsBut sliding mechanics at first also had disadvantages:1. No established guidelines on amounts of force to be used during space closure2. Tendency for initial overactivation of elastic and spring forces, causing initial tipping and inadequate rebound time for uprighting
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
To maximize the advantages and minimize the disadvantages of sliding mechanics• force levels are reduced during space closure.
• Instead of springs or over activated elastics (which can produce 500g of force), single elastic modules are attached to anterior archwire hooks with ligature wires extended forward from the molars
These "elastic tiebacks", when activated 2-3mm, generate about 100-150g of force.
If the arches have been properly leveled, such light force allows for effective space closure; there is little tipping with subsequent binding of the archwires, and leveling is maintained
.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
019" × .025" archwires with .022" slots provide optimum rigidity, but adequate freedom for the wires to slide through the slots.
Round wires and smaller rectangular wires provided less precise control of torque, curve of Spee, and overbite.
Hooks of .024 " stainless steel or .028 " brass are soldered to the upper and lower archwires
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Space closure typically occurs more easily in high-angle patterns with weak musculature than in low-angle patterns with stronger musculature. The rate of closure can be increased, particularly in high-angle cases, by slightly raising the force level or using thinner archwires. However, more rapid space closure can lead to loss of control of torque, rotation, and tip.
Effects of Overly Rapid Space Closure
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Loss of torque control results in upper
incisors being too upright at the end of
space closure with spaces distal to the
canines and a consequent unaesthetic
appearance. The lost torque is difficult
to regain. Also, rapid mesial movement
of the upper molars can allow the
palatal cusps to hang down, resulting in
functional interferences, and rapid
movement of the lower molars causes
"rolling in"
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Reduced rotation control can be seen mainly in the teeth adjacent to extraction sites, which also tend to roll in if spaces are closed too rapidly Reduced tip control produces unwanted movement of canines, premolars, and molars, along with a tendency for lateral open bite. In high-angle cases, where lower molars tip most freely, the elevated distal cusps create the possibility of a molar fulcrum effect www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
In some instances, excessive soft-tissue hyperplasia occurs at the extraction sites ,this is not only unhygienic, but it can prevent full space closure or allow spaces to reopen after treatment. Local gingival surgery may be necessary in such cases.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Proper alignment of bracket slots is essential to eliminate frictional resistance to sliding mechanics. The common procedure is to use .018" or .020 " round wire for at least one month before placing .019"´.025" rectangular wires. Leveling and aligning continues for at least a month after insertion of the rectangular wires, and that space closure cannot proceed during that period.
Inhibitors to Sliding Mechanics
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Therefore the rectangular wires are tied passively for at least the first month, until leveling and aligning is complete and the archwires are passively engaged in all brackets and tubes
Conventional elastic tiebacks are than placed ,In some cases, this phase takes three months.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
First-order or rotational resistance
at the mesiobuccal and distolingual aspects of the posterior bracket slots is produced by rotational forces on the buccal aspects of the posterior teeth.
The most effective way to counteract this resistance is to apply intermittent lingual elastic forces— one month from cuspid to first molar, the next month from cuspid to second molar.
There are three primary sources of friction during space closure
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Second-order or tipping resistance
at the mesio-occlusal and distogingival aspects of the posterior bracket slots is caused by
excessive and overactivated tieback forces, which lead to • tipping of the posterior teeth, • inadequate rebound time to upright these teeth,• and a resultant binding of the system.
The importance of light forces (50-150g) and minimal activation length (to provide time for uprighting) cannot be overemphasized.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Third-order or torsional resistance
occurs at any of the four areas of the bracket slot where the edges of the archwire make contact.
Like tipping resistance, this is produced mainly by
excessive and overactivated tieback forces, which cause the upper posterior lingual cusps to drop down and the lower posterior teeth to roll in lingually
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Since forces are directed from the first molars to anterior hooks on the archwire, small spaces occasionally open between the first and second molars.
This can be managed in one of three ways: A damaged lower premolar or first molar bracket, either from careless use of biting sticks during bonding or from improper diet, can hinder space closureInterference from opposing teeth sometimes restricts lower arch space closure, particularly if bracket placement was incorrect or a full-unit Class II molar relationship existed.
Problems During Space Closure
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
As spaces close, the distal ends of the archwires will protrude
more and more, and these protruding wires will tend to become
bent gingivally by chewing forces
Certain tissue factors can hinder full space closure with any kind
of mechanics. Soft-tissue build-up can result from poor plaque
control or overly rapid space closure. The alveolar cortical plate,
mesial to the lower first molars, tends to narrow after extraction of
the second premolars, especially in lower-angle situations.
Retained roots, ankylosed teeth, and bone sclerosis are other
possible factors to be considered.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
1. Inadequate leveling, resulting in archwire binding
2. Posterior torque such that torquing and sliding cannot occur
simultaneously
3. Blockage of the distal end of the main archwire by a ligature wire
4. Damaged or crushed brackets that bind the main archwire
5. Soft tissue resistance from build-up in extraction sites
6. Cortical plate resistance from a narrowing of the alveolar bone in
extraction sites
7. Excessive force, causing tipping and binding
8. Interferences from teeth or the opposing arch
9. Insufficient force
Constant attention is required to prevent any of the following inhibiting factors:
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
BIOMECHANICS OF CANINE RETRACTION ON A CONTINUOUS ARCHWIRE
ROBERT J NIKOLAI SEMIN ORTHOD 2001www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Friction is a function of the relative roughness of two surfaces in contact. It is the force that resists the movement of one surface past another and acts in a direction opposite the direction of motion.
VARIABLES AFFECTING FRICTIONAL RESISTANCE DURING TOOTH MOVEMENT
PHYSICAL
ARCHWIRE
LIGATION
BRACKET
ORTHODONTIC APPLIANCE
BIOLOGICAL
SALIVA
PLAQUE
ACQUIRED PELLICLE
CORROSSION
NANDA& KULHBERGwww.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure PHYSICAL
ARCHWIREcrossectional size/shapematerialsurface texturestiffness
LIGATIONligature wireselastomericsself ligating brackets
BRACKETmaterialmanufacturing processslot width and depthfirst/second/third order bends
ORTHODONTIC APPLIANCEinterbracket distancelevel of bracket slots between adjacent teethforces applied for retraction
BIOLOGICAL
Saliva Plaque Acquired pellicle Corrosion
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The segmental arch technique as developed by Burstone utilizes T loop space closure springs for anterior retraction, symmetric closure or posterior protraction.
The segmental T loop as described by Burstone is one of the most versatile space closure devices available.
One of the main principles of the segmental arch technique is considering the anterior segment and posterior segment as one large tooth respectively. The right and left buccal units are connected by a transpalatal arch forming one big posterior unit.
The basic configuration of the TMA loops consists of a .017X.025” TMA wire.
CHARLES J BURSTONE AJO-DO 1982www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The rate of decay of the force applied by a spring is called the load-deflection rate, and it averages 33 Gm. per millimeter in the Burstone’s T loop.
The low load-deflection rate is important in this spring, since it enables the orthodontist to deliver optimal magnitudes of force.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
High-load deflection springs as vertical loops dissipate force rapidly; hence, one must activate to very high force levels in order to produce any significant tooth movement.
Since the load-deflection rate is so high, it would be impossible for a clinician to activate the loop to produce an optimum magnitude of force. To deliver 200 Gm. of force, the required activation would be 0.2 mm. Not only is it practically impossible to activate such a small distance, the force of 200 Gm. would be dissipated rapidly over the remaining 0.2 mm. of activation. Thus, orthodontists who use high-force load-deflection mechanisms must use high force values that have undesirable sequelae, which include anchorage loss, pain, and undermining resorption.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
In contrast, a retraction spring with a low load-deflection rate of 33 Gm. per millimeter allows for the delivery of optimal force levels, since an error in activation of 1 mm. results in an error of only 33 Gm. Furthermore, as teeth move distally, the reduction in force is small, giving greater constancy of force at optimal levels.
Early in treatment, the posterior teeth are joined together to form a
posterior anchorage unit.
The anchorage unit consists of the right and left posterior teeth which
are connected by a buccal stabilizing segment and a transpalatal lingual
arch in the maxillary arch and a low lingual arch in the mandibular arch
During space closure, it is to be considered that there are only two teeth
— an anterior tooth comprising the incisors and the canines which have
been connected and a posterior tooth which includes molars and
premolars www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
.
The attachment on the posterior tooth (segment) is a 0.018 by 0.025 inch
auxiliary tube on the first molar, and the one on the anterior tooth (segment)
is an auxiliary vertical tube on the canine bracket
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
STANDARD FORM OF .017x.025 TMA LOOPS
WITHOUT PREACTIVATION BENDS
PREACTIVATION FORM OF THE SPRING DESIGNED TO PRODUCE EQUAL AND
OPPOSITE ALPHA AND BETA MOMENTS WHEN POSITIONED
IN CENTERED POSITION
Stanley Braun,. Sjursen, Jr., Legan, AJO-DO 1995www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
To understand its design one must
first understand its passive form of
the spring and then its activation.
In the passive state there are no
moments or forces acting on it. In
its active state it applies a force
system on the teeth,
The activation of a spring requires
forces and moments to engage the
spring in its brackets and tubes.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Neutral position:
The neutral position in an activated
loop is found by applying the
activation moments and without any
horizontal forces. In other words the
ends are twisted to bring the each
attachment to its horizontal position.
in this position the spring has zero
horizontal force
The horizontal force is got by pulling
the spring open from this position.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Differential moments are obtained by the principle of off center V bends which results in unequal moments. the closer the V bend is to the tooth the higher the moment. the segmented T loops approximated a V bend. Clinically the spring needs to be positioned at least 1-2mm closer
to one side than another to obtain a moment differential.www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure With the introduction of beta-titanium wire (TMA), it has been
possible to simplify the design so that a T loop by itself will have
a relatively low load-deflection rate and a large maximum
springback. The heavier base arch which fits into the auxiliary
tube of the first molar is important, since it allows positive
orientation of the spring and, more significantly, it is capable of
withstanding, without permanent deformation, the higher
moments that are needed for anchorage control. Furthermore, the
use of a heavier base arch tends to increase the moment-to-force
ratio on the anterior teeth, since any bending in the occlusally
positioned part of the spring tends to minimize this ratio.
To aid the clinician in achieving the proper angulation, templates
are used. Rather than to measure the angles, it is more
expeditious to duplicate the shape of the spring from a template. www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The T loop described in
Biomechanics by Nanda is designed
for an activation upto 6 mm.at full
6mm activation tooth movement
occurs in three phases: tipping,
translation and root movement.
For a symmetric centered spring an
initial activation produces a M/F
ratio of 6/1 which results in tipping
movement of the teeth into the
extraction space.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
With 2mm deactivation or spring activation = 4mm the M/F ratio is 10/1 which results in translation of the segments towards each other. With 1-2mm space closure (spring activation =2mm) the M/F ration increases to 12/1 and higher resulting in tooth movement. Clinically the spring should not be re activated till all three phases are complete.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
This demonstrates another method that may be used for controlling the forces and moments produced by segmented 0.017 ´ 0.025-inch TMA T-loop springs or closing loops in general.
Previously, the approach described for achieving differential alpha/beta moments with segmented T-loops used asymmetric angulations of the preactivation bends.
However, with this method the moment differential does not remain constant with spring activation, i.e., the moment differential is dependent on both spring activation and the differences in the preactivation angulations.
OFF CENTERED T LOOPS
Andrew Kuhlberg, Charles J. Burstone AJO-DO 1998www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Off-center positioning maintains
the constancy of the moment
differential throughout the range of
spring deactivation (space closure).
This concurs with Burstone and
Koenig who demonstrated a
moment differential and vertical
forces with off-center vertical
loops.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The effect of off-center placement of T-loops with a standard shape at a standardized activation and interbracket distance. A centered T-loop produces equal and opposite moments with negligible vertical forces. Off-center positioning of a T-loop produces differential moments. More posterior positioning produces an increased beta moment. More anterior positioning produces an increased alpha moment. A standard shaped T-loop can be used for differential anchorage requirements by altering the activation and mesial-distal position of the spring.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The center position of the spring can be found by:distance = (interbracket distance –activation)/ 2
where distance = length of the anterior and posterior arms (distance from the center of the T loop to either the anterior or posterior tubes)
interbracket distance=distance between the canine and molar brackets.
Activation= millimeters of activation of the springwww.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
With the use of a vertical tube at
the canine a 90 degrees gingival
bend at the calculated distance
eases placement and monitoring
throughout space closure
The T loop is places in the
molar auxiliary tube and then
inserted into the canine bracket.
The distal end is pulled back
until it is the desired length
which results in the desired
activation.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure Force systems related to type A, B, and C extraction site closure
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The T loop is positioned closer to the posterior segment (1-2 mm off centering) is sufficient .activation of 4 mm is necessary. This reduces the horizontal forces without altering the moment differential. The force system acting on the anterior segment favors tipping. The moment difference remains as the space closes and the spring deactivates.The spring must be re activated when 2 or less mm of activation remains.
MAXIMUM POSTERIOR ANCHORAGE:
(Group A anchorage)
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Because the beta moment is greater than the anterior moment a vertical intrusive force acts on the anterior teeth which can exaggerate the tipping tendency and steepen the occlusal plane. Similarly the posterior occlusal plane can be steeped buy the extrusive force. Maintaining adequate horizontal force helps to reduce this effect. A High pull headgear can also be used to control the posterior occlusal plane. It is likely that root correction will be required at the end of space closure. www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
TPA
FIRST ORDER VIEW OF A T-LOOP SPRING WITH A
V-BEND INCORPORATED FOR ROTATIONAL CONTROL
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
This is the most difficult of all space closures. The increased alpha moment has a tendency to deepen the overbite.
The loop must be placed 1-2mm closer to the anterior teeth.
Care must be taken that the wire segment achieves full bracket engagement because play can reduce the moment differential.
Space closure with tipping of the buccal segments will occur.
MAXIMUM ANTERIOR ANCHORAGE :( Group C anchorage)
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
the activation must be around 4mm and should be activated every 2mm.
The major side effects are loss of anchorage and extrusion of the anteriors.
Class III elastics or protraction headgear may help in the protration of the upper buccal segments.
For mandibular molars class II elastics may help.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Segmental T loop space closure principles can also be applied to space closure on a continuous arch.
the force system is not as well defined a the segmental but careful use of the alpha and beta moments helps to achieve comparable results especially for group B and C anchorage cases.
For group A cases high pull headgear is necessary to control tooth position.
T loops one on each side are made using preformed arch wires .017 X .025 TMA or .016 X .022 Stainless steel arch wire.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The activations given are for TMA wires and the Stainless
steel wires activation is reduced by half.
The T lops are made 6-7mm tall and 10mm wide and are
positioned distal to the cuspids.
Desired alpha and beta moments are place anterior and
posterior to the T loop vertical legs.
Recommended beta activations for A, B, and C anchorages are
40 degrees, 30 degrees and 20 degrees.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
After the activations are placed the loops should be open
approximately 2mm before placing in the mouth. the wire is inserted
into the molar auxiliary tube and ligated to the anterior teeth. The t loop
bypasses the premolars brackets and is not inserted in them.
For TMA loops the activation can be 3mm distal to the molar tube
which gives it a range of force of 250-300gms.
The patient should be monitored but no further activations are
necessary for 2-3 months. Too frequent reactivation can prevent root
movement and cause excessive tipping
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
From the Occlusal view the first order side effect of rotation of the molars and canines are observed.
Rotation of the molars can be prevented by use of a transpalatal arch. (rectangular wires only not round wires TPA)
Control of canine rotation can be achieved by a variety of techniques.
CONTROL OF THE MECHANICAL SIDE EFFECTS OF SPACE CLOSURE:
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
For enmasse retraction a rigid anterior segment can reduce this tendency. A canine bypass connecting he canines but bypassing the incisors can also control rotation. thirdly a anti rotation bend can be incorporated into the spring.
With asymmetric space closure vertical forces may be produced. these may produce undesired extrusive or intrusive tooth movements. these vertical forces may also produce third order side effects.
With group A space closure the third order side effect on the canine is troublesome the intrusive force causes a buccal flaring which increases the overjet at the canine and/or increases the intercanine width.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
CONTROL OF THE SIDE EFFECTS OF SPACE CLOSURE:
Careful monitoring is essential during space closure.
A frequently overlooked side effect of space closure is the first order
side effects.
The mesially directed buccally located force of the molar may lead to
the erroneous supposition that there is anchorage loss.
Distalization is not necessary . A mesially out directed force is all that is
needed to regain the original molar position.
A transpalatal arch provides an excellent mean to prevent this or actively
corrects it.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
CORRECTION OF THE SIDE EFFECTS
Tipping of the anterior and posterior teeth into the extraction spaceIncrease the alpha and beta moments
Flaring of the anterior teethReduce the alpha moment or increase the distal activation
Mesial in rotation of the buccal segmentsMesial out rotation of the palatal arch, archwire or lingual arch
Excessive lingual tipping of the anterior teethIncrease the alpha moment
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Rotating moments caused by buccal forces during extraction site closure.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The OPUS loop was designed to deliver an inherent M/F ratio sufficient for enmasse space closure via translation of teeth of average dimensions with no bone loss.
Because its inherent M/F ratio is high enough no preactivation bends is needed before insertion
The neutral position is the passive position of the spring as it sits before insertion.
Simple cinch back activations can take care of the tooth movement thresholds to meet anchorage objectives.
Raymond E SiatkowskiSemin Orthod 2001
AJO-DO 1997www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
No closing loop design previously has been capable of delivering at constant M/F of 8.0 to 9.1 mm most having inherent M/F of 4-5 mm or less. To achieve net translation, orthodontists have had to add residual moments to the closing loop arch wire with angulation bends (gable bends) anterior and posterior to the loop, a posterior gable bend and angulations within the loop, or a posterior gable bend and anterior wire-bracket twist (anterior root torque).
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure Adding these residual moments has several disadvantages:
1. The teeth must cycle through controlled tipping to translation to root movement to achieve net translation (lower Young's Modulus materials go through fewer of these cycles for a given distance of space closure). 2. The correct residual moments are difficult to achieve precisely in linear materials. 3. The resulting ever-changing PDL stress distributions may not yield the most rapid, least traumatic method of space closure.
If a closing loop design capable of achieving inherent, constant M/F of 8.0 to 9.1 mm without residual moments were available, en masse space closure with uniform PDL stress distributions could be achieved. Such a mechanism would be less demanding of operator skill to apply clinically and might provide more rapid tooth movement with less chance of traumatic side effectswww.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The opus loop achieves a M/F ratio of 8-9.1mm without addition of activation bends in the loop or archwire itself. Therefore its neutral position is the same as the inactivated position before it was tied into the brackets. Having the loops neutral position accurately allows known forces systems to be applied to the teeth via simple cinch back activations.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The apical horizontal leg is 10mm long, The ascending legs at an angle of 70 degrees to the plane of the
brackets The apical helix is on the leg ascending from the anterior teeth, (that
ascent must begin within 1.5mm posterior to the most distal bracket of the anterior teeth being retracted)
The spacing between the ascending legs especially the apical loops legs must be 1mm or less All these dimensions are critical to the performance of the loop. Clinically comfort bends are not necessary.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Being free of residual moments, the design can produce a true rest period when deactivated and therefore could be used with future technology to produce intermittent force systems during space closure.
Wire bracket play numbers as given in the figure shows that it is important that sufficient lingual twist exists in the arch wire engaging the incisors so that bracket wire play is reduced for axial control of the incisors.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
It is appropriate to begin with a straight wire and bend the arch wire in a torquing turret to achieve incisor axial inclination control by inducing wire twist ("lingual root torque") just enough to eliminate labiolingual wire-bracket play in the incisor brackets. The amount of such twist is dependent on the wire/bracket sizes and slot torque usedA torquing turret has been designed for use with TMA wire. Maximum incisor twist is appropriate for posterior protraction
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The advantage of having the opus loop formed in 17X25 TMA is that it provides a relatively long range of activation;
unfortunately it is difficult to bend the wire with sufficient incisor torque to reduce the wire play.
It is difficult to contour the loop for comfort on one side without altering the other side also and a large stock of wires is necessary for preformed wires.
This can be over come by having:
An anterior wire of Niti alloy with two separate 17X25 TMA posterior segments, which are attached by a Forestadent cross tube
This bialloy has the following advantages: Infrequent activations Ease of comfort bending Incisor axial inclination control
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The OSTEOLOGIC graphic form is
the theoretical explanation for the
mode of action of the opus loop
arch wire.
It relates the orthodontic force
systems to the stresses in the PDL
rather than the strains.
It examines the rate of tooth
movement as the loop deactivates
Melsen refinement of the Quinn Yoshikawa model of tooth movement:
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
When a force system is applied on a tooth initially after a quiescent period, the initial rate of tooth movement corresponds to no 2 on the diagram.This model is valid only for uniform stress on the PDL as produced by translation and not tipping followed by up righting.These arch wires by definition are activated far less than the systolic blood pressure at which hyalinization is supposed to occur.
Larger cinch back activations shift the curve to the right and a lesser activation shifts the curve to the left
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The various possible activations of the opus lop cinch back as a function of time is shown in the figure.
Group B anchorageCurve 1: anteriors retractCurve 2: posteriors protract
Group A anchorageCurve 2: anteriors retractCurve 3: posteriors little change
Group C anchorageCurve 4: anteriors no changeCurve 1 posteriors protractwww.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
Although less so than with other closing loop designs, Opus loops do have the potential to steepen the cant of occlusal plane in the maxillary arch and flatten it in the mandibular arch.Although steepening occlusal plane can be useful for overtreatment of Class III relationships (and flattening occlusal plane for Class II relationships), that potential should be monitored for possible intervention. Such intervention could be reducing maximum activation force levels or using an occipital headgear with short and high outer bows to generate a moment tending to flatten maxillary occlusal plane.For the most severe anchorage required to achieve treatment goals, second molars, if available, could be included with the posteriors and/or a Combi headgear used. For less severe or moderate anchorage, the canines could be incorporated with the anteriors
DISADVANTAGES OF THE OPUS LOOP
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The closing loop arch wire generates the moments required and some of the protraction force. Most of the protraction force is generated by the large anterior moment and by the intermaxillary elastics to a rigid rectangular arch wire in the opposing arch.
Intermaxillary Niti closed coil springs capable of delivering 150 gm force can be substituted for the elastics. The potential exists for changing occlusal plane in the opposing arch. Should such cant changes begin to be observed, the intermaxillary force can be reduced.
The configuration for posterior protraction
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
In group C anchorage cases, class III elastics with a force of 150gms/side from the opposite arch which has a rigid rectangular stainless steel archwire can be used.
Another alternative is to use TP 256 torquing auxiliary which when overlaid over the closing loop provides an additional protraction force to the posteriors.
It has the following advantages: The clinician is free to continue treatment in the lower arch Undesired vertical forces from the elastics are not a problem Posterior arch width increases are not a problem when using a
TMA wire
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The advantages of the T-loop design over a vertical loop is that the T-loop produces a higher M/F ratio, a lower load-deflection rate, and delivers a more constant force and M/F ratio
Often in adult patients, where no growth is anticipated, extraction therapy is performed. The situation is often complicated through loss of bone. In order to maintain an assumed stress magnitude and distribution under the condition of reduced bony support area, force magnitude must be reduced and the M/F ratio must be increased.
The necessity of producing a lower load deflection rate in such cases suggests the use of a wire with lower stiffness
SEGMENTED ARCH TECHNIQUE FOR SPACE CLOSURE IN ADULTS:
Manhartsberger, Morton, Charles J Burstone Angle 1989www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
With a change in the center of resistance the M/F ratio must be modified thus, in adult patients with periodontal loss, higher M/F values must be attained.
To obtain higher M/F ratios a number of strategies can be employed.
The loop can be made as long as possible in an apical direction. By increasing the height of the loop to 11 millimeters, one will approximately double the M/F ratio. However, there are limitations to how far apically the loop can extend before irritation is produced in the mucobuccal fold.
Another approach is to increase the amount of wire placed gingivally at the top of the loop, as in the T-loop .
Increasing the gingival length of wire (dimension G) increases the M/F ratio and reduces the load deflection rate.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The variation of the center of resistance with differing levels of bony support.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The T-loop dimensions (H=7mm, D=2mm, G =10mm).
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
TMA T-loop with gradual curvature angulation.
A .016² × .025² TMA T-loop activated five millimeters with gradual curvature bends in comparison to a .017² × .025² TMA T-loop
activated seven millimeters produced a 47 percent lower horizontal force, and a 23 percent higher M/F ratio.
The actual spring must be individualized for each patient by altering wire cross-section, angulation, and activation.
T-loop with concentrated angulation.
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
The clinical discipline of orthodontic space closure requires complete understanding of
its complexitiesJust as an orthodontist is provided with innumerable alternatives of appliance
systems, it is imperative to be aware it the merits as well as the limitations of the
techniques involvedMechanical as well as biologic factors must
be considered in selecting the appliance best suited for the patient
www.indiandentalacademy.com
Bio
mec
hani
cs o
f Sp
ace
Clos
ure
www.indiandentalacademy.com
www.indiandentalacademy.comLeader in continuing dental education