B11 SHIMS UNDER PEDESTALS PLACE B11s (WHOLE OR IN SEGMENTS) UNDER THE PEDESTAL IN A STAIRSTEP FASHION TO COMPENSATE FOR SLOPING SUBSTRATES. USE ONLY B11 SHIMS FOR THIS APPLICATION. MAXIMUM (3) THREE. Installation & Slope Compensation Details Details12/5/2006©UCP BISON DECK SUPPORTS ......THE LEVEL OF EXCELLENCE © SAMPLE LAYOUT USING WOOD TILES OR PAVERS ALL PEDESTAL TABS REMOVED TWO PEDESTAL TABS REMOVED USE ALL FOUR PEDESTAL TABS TO DETERMINE THE NUMBER OF PEDESTALS: 1. COUNT ONE (1) PEDESTAL FOR EACH TILE/PAVER USED. (DIAGRAM: 12 TILES) 2. ADD ONE (1) PEDESTAL FOR EACH PERIMETER TILE ON 2 SIDES (DIAGRAM: 6 + 12 = 18) 3. ADD TWO (2) PEDESTALS TO THE TOTAL (DIAGRAM: 18 + 2 = 20 PEDESTALS NEEDED) B11 SHIMS ON TOP OF PEDESTALS B11’S MAY BE PLACED ON TOP OF PEDESTALS TO ACCOMODATE FOR MINOR LEVEL- ING OF PAVERS WITH THICKNESS VARIATIONS. NOTE: 1/4 WEDGE PIECES MUST BE ADHERED TO THE PEDESTAL & EACH OTHER WITH CONSTRUCTION ADHESIVE, SECURING THE WEDGE TO THE PEDESTAL AND NOT MORE THAN 2 WEDGES TOGETHER. SLOPE COMPENSATION DETAILS TOP LEVELING: PH5 = UP TO 5/8” PER FOOT SLOPE. ROTATE THE PH5 TO PRECISELY LEVEL THE PEDESTAL TOP ON SURFACES WITH SLOPE UP TO 5/8” PER FOOT. COMES STANDARD ON ALL VERSADJUST MODELS & CAN BE ADDED TO LEVEL.IT MODELS. BASE LEVELING: LD4 = 1/4” PER FOOT SLOPE STACK 2-4 LD4’S UNDER PEDESTAL BASE TO COMPENSATE FOR 0”-1” PER FOOT SLOPE. WHEN USING TWO OR MORE LD4’S ROTATE ONE IN RELATION TO THE OTHER TO ACHIEVE THE RIGHT SLOPE COMPENSATION bison deck supports USE ¼ PIECE W/ CONSTRUCTION ADHESIVE 90˚ 90˚

Upload: others

Post on 18-Dec-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

B11 SHIMS UNDER PEDESTALSPLACE B11s (WHOLE OR IN SEGMENTS) UNDER THE PEDESTAL IN A STAIRSTEP FASHION TO COMPENSATE FOR SLOPING SUBSTRATES. USE ONLY B11 SHIMS FOR THIS APPLICATION. MAXIMUM (3) THREE.

Installation & Slope Compensation Details

Details12/5/2006©UCP

BISON DECK SUPPORTS ......THE LEVEL OF EXCELLENCE©

SAMPLE LAYOUT USING WOOD TILES OR PAVERS

ALL PEDESTAL TABS REMOVED

TWO PEDESTAL TABS REMOVED

USE ALL FOUR PEDESTAL TABS

TO DETERMINE THE NUMBER OF PEDESTALS:1. COUNT ONE (1) PEDESTAL FOR EACH TILE/PAVER USED. (DIAGRAM: 12 TILES)2. ADD ONE (1) PEDESTAL FOR EACH PERIMETER TILE ON 2 SIDES (DIAGRAM: 6 + 12 = 18)3. ADD TWO (2) PEDESTALS TO THE TOTAL (DIAGRAM: 18 + 2 = 20 PEDESTALS NEEDED)

B11 SHIMS ON TOP OF PEDESTALSB11’S MAY BE PLACED ON TOP OF PEDESTALS TO ACCOMODATE FOR MINOR LEVEL-ING OF PAVERS WITH THICKNESS VARIATIONS. NOTE: 1/4 WEDGE PIECES MUST BE ADHERED TO THE PEDESTAL & EACH OTHER WITH CONSTRUCTION ADHESIVE, SECURING THE WEDGE TO THE PEDESTAL AND NOT MORE THAN 2 WEDGES TOGETHER.

SLOPE COMPENSATION DETAILS

TOP LEVELING: PH5 = UP TO 5/8” PER FOOT SLOPE. ROTATE THE PH5 TO PRECISELY LEVEL THE PEDESTAL TOP ON SURFACES WITH SLOPE UP TO 5/8” PER FOOT. COMES STANDARD ON ALL VERSADJUST MODELS & CAN BE ADDED TO LEVEL.IT MODELS.

BASE LEVELING: LD4 = 1/4” PER FOOT SLOPESTACK 2-4 LD4’S UNDER PEDESTAL BASE TO COMPENSATE FOR 0”-1” PER FOOT SLOPE. WHEN USING TWO OR MORE LD4’S ROTATE ONE IN RELATION TO THE OTHER TO ACHIEVE THE RIGHT SLOPE COMPENSATION

bisondeck supports

USE ¼ PIECE W/ CONSTRUCTION ADHESIVE

90˚ 90˚

SECTION VIEW 1B

EDGE OF 4’ X 4’DRAIN SUMP

ROOF DRAIN

1/4” PER FT. SLOPE (TYP)IN THE FIELD OF THE ROOF

USE LLD4’s FOR SLOPECOMPENSATION

SECTION VIEW 1B

INSERT & ADHERETAB IN PLACE

SPECIAL PLACEMENTS

PERIMETER

EDGE PEDESTALS WITH 2 TABS REMOVED (TYPICAL)

DOOR THRESHOLDNOTE: PEDESTAL HEIGHT EQUALS DISTANCE FROM THRESHOLD TOSURFACE BELOW, MINUSDECK SURFACE MATERIAL THICKNESS

CORNERPEDESTALS ALL 4 TABS REMOVED (TYPICAL)

NARROW FIELD CUT PAVERS

STANDARD PEDESTAL PLACEMENT USING ALL 4 SPACER TABS (TYPICAL)

ENLARGED PLAN VIEW

1A

BISON DECK SUPPORTS

©UCP2005

SECTION VIEWMINIMAL SLOPE COMPENSATION(NOT TO SCALE)

STONE, CONCRETE OR WOOD PAVER / TILE

TOP OF PAVER / TILE

PEDESTAL WITH TABSREMOVED AS NECESSARY 3/16”

(STANDARD)

LLD4 APPLIED FOR STANDARDSLOPE COMPENSATION

1A

©UCP2005

©UCP2006

1C

ENLARGED PLAN VIEW AT DIAGONAL PERIMETER EDGE

SECTION VIEW 1C

2 PEDESTALSSHOWN WITH TABSREMOVED ANDREINSERTED ASNECESSARY

FIELD CUT PAVERS

REINSERT TABS &ADHERE IN PLACE

CUT OFF BASEFLANGE FOR CLOSEPERIMETER

TOP OF PAVER

STEP DOWN OPTION #1 STEP DOWN OPTION #2

ENLARGED PERIMETER EDGE DETAIL

GROUND APPLICATION DETAIL (FFB)

USE FLOATING FOUNDATION BASE (FFB) UNDER EACH PEDESTAL PLACED ON THE GROUND

INSULATION APPLICATION DETAIL (FIB)

REINSERT TABS & ADHERE IN PLACE WITH CONSTRUCTION ADHESIVE

PERIMETER EDGE

ADHERE SMALLPAVER TO TOPOF PEDESTAL

CUT BASE FLANGE FORCLOSE FIT PERIMETER

ADHERE SMALL PAVER SECTIONS TO TOPOF PEDESTAL WITH WATERPROOF ADHESIVE

BOTTOM VIEW OF PEDESTAL

FACTORY SCOREDGUIDELINES FOREASY CUTTINGCUT BASE FLANGEAS NECESSARYFOR CLOSEPERIMETER

TOP VIEW OF PEDESTALSECURING PERIMETER FACIAON GRADE

TREATED FACIA BOARD

TREATED WOOD SPACER3 1/2” TEK SCREWGRADE

CONCRETE PAVER OR WOOD TILE

PEDESTALFFB

INSTALLATION DETAILS

©UCP2005

©UCP2005

©UCP2005

©UCP2005

©UCP2005©UCP2005

©UCP2005©UCP2005

REQUIRED: FLOATING INSULATION BASE (FIB) MUST BE PLACED UNDER EACH PEDESTAL USED ON SMOOTH SURFACED ROOFING MEMBRANES WITH INSULATION.

NOTES:1. ALL DRAWINGS & DETAILS PROVIDED ARE EXAMPLES ONLY.2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS.3. DRAWINGS NOT TO SCALE.4. FOR COMPLETE SPECIFICATIONS, PRODUCT AND PURCHASING INFORMATION VISIT www.BisonDeckSupports.com

MORE APPLICATION & TRANSITION DETAILS

TWO LAYER FLOOR PANELS FOR STAGES24”

BACKSET LOWER PANEL ONALL SIDES1/8” tab 3/16” tab

DIMENSIONAL JOISTS WITH DECK

OPTIONAL CORNER BRACKET

4 X 4 2 X 4Or other 2X product

2 FT. WOOD TILE 2 FT. CONCRETE OR STONE PAVER

SHIMS

STEP SHIM FOR SLOPE(IF NEEDED)

NOTE::SEE SLOPE COMPENSATION DETAILS FOR STEP SHIMS

FS1 FASTENER SYSTEM -ATTACHES LEVELIT TILES TO PEDESTAL

WOOD TILE TO PAVER TRANSITION

BASE FLANGE CAN BE TRIMMED

2 x 4

WOOD TO PAVER TRANSITION

BASE FLANGE CAN BE TRIMMED

1.75” PLANKING

WOOD PLANKING TO PAVER TRANSITION

CONTINUOUS 2X STRINGER

OPTIONAL SLEEPER AT JOISTS

DIMENSIONAL STRINGERS WITH SUBFLOOR

a United Construction Products, Inc. Company www.BisonDeckSupports.com 1975 W. 13th Ave. Denver, CO 80204 Ph: (303) 628-7950 Fax: (303) 825-5988 Toll Free: (888) 412-4766

©10/1/2005UCP

LEVEL.IT SAFETY WINDOWS

TO ENSURE PEDESTAL STABILITY, SCREW PIECES TOGETHER UNTIL SAFETY WINDOWS ARE COMPLETELY COVERED.

PRODUCT #: FS1 FASTENING KIT. SCREW ANCHOR INTO TOP OF PEDESTAL. ADJUST WASHER TO FASTEN BETWEEN THE BOTTOM RAIL OF THE TILE AND THE UPPER SLAT. SCREW WASHER INTO ANCHOR AND TIGHTEN.

WOOD TILE ANCHOR SYSTEM

VERSADJUST VDPH5 DESIGN FEATURES

8 attachment holes (if needed)

Screw adjustment regulator,up to 1 3/8”

Adjustable Coupler up to 4 1/2”

Slope Compensator,to 5/8” per foot

Base surface area: 47”

Collar for bracing at elevations over 16”

1/8” Spacer Tabs (Removable)

4.5mm Spacer Tabs (Removable)

Preset Height Indicator

Versadjust Key ToolAvailable

To release “stop lock”, unscrew pedestal until it stops & insert a nail into the hole, as shown, to release the tab.