    1BIZARRE EMI INCIDENTS

    Naval EMC CentreMumbaiWelcomes you to

    Bizarre EMIIncidents

    Lt Cdr A Saxena

  • 8/6/2019 Bizarre EMI Incidents

    2/61

    2BIZARRE EMI INCIDENTS

    Patients arm amputated blood

    circulation monitoring system failed dueto plastic welding machine.

    Security breached data loaded on a PC

    by wireless keyboard in another room 150metres away.

    Ships data-log failure automated

    system resets every night at 2300 hrs.

  • 8/6/2019 Bizarre EMI Incidents

    3/61

    3BIZARRE EMI INCIDENTS

    Bizarre yet True !!

    Welcome t o the

    wor ld o fEMI

  • 8/6/2019 Bizarre EMI Incidents

    4/61

    4BIZARRE EMI INCIDENTS

    IntroductionHow Interference Takes PlaceSources of EM EnergyCoupling Paths

    Bizarre Incidents

    Aviation

    MedicalGeneral Engineering

    Naval

    Way - Points

  • 8/6/2019 Bizarre EMI Incidents

    5/61

    5BIZARRE EMI INCIDENTS

    All electronic equipmentemit EM energy.

    When coupled to otherdevices, this energy candegrade their

    performance - called EMI.

    ELECTROMAGNETICINTERFERENCE

  • 8/6/2019 Bizarre EMI Incidents

    6/61

    6BIZARRE EMI INCIDENTS

    All three elementsmust exist together

    for EMI to occur

    Source Victim

    Coupling Path

    EMI

    Conduction Radiation

    ELEMENTS OF EMI

  • 8/6/2019 Bizarre EMI Incidents

    7/617BIZARRE EMI INCIDENTS

    Natural: Due to Natural Phenomena.Solar/Cosmic/Thunderstorm/Lightning

    Incidental: From Sources, Not Intended to

    Radiate.Functional: From Sources, Intended to

    Radiate.

    Secondary Sources: Interaction of EMEnergy and other metallic structures likeframes, hull etc.

    SOURCES OF EMI

  • 8/6/2019 Bizarre EMI Incidents

    8/618BIZARRE EMI INCIDENTS

    Designed to radiate energy during normaloperation

    OWN JAMMERS

    MISSILESEEKERHEADS

    COMMUNICATIONLINKS

    (SHIPS / AIRCRAFTS/ UAV / MISSILES)

    RADARS

    FUNCTIONAL SOURCES

  • 8/6/2019 Bizarre EMI Incidents

    9/619BIZARRE EMI INCIDENTS

    Not designed to radiate EM energy

    DC MOTORS

    ELECTRICALCONTROLLER

    S

    ENGINES&

    IGNITERS

    COMPUTERS POWERLINES

    WELDINGMACHINES

    FLUORESCENT LIGHTING

    INCIDENTAL SOURCES

  • 8/6/2019 Bizarre EMI Incidents

    10/6110BIZARRE EMI INCIDENTS

  • 8/6/2019 Bizarre EMI Incidents

    11/6111BIZARRE EMI INCIDENTS

    ConductedPower lines

    Signal lines

    Radiated

    Directly on systemOn to cables connected to the system

    COUPLING PATHS

  • 8/6/2019 Bizarre EMI Incidents

    12/6112BIZARRE EMI INCIDENTS

    CommonPowerSupply

    Source of Transient/ EMI

    Victim

    ConductedEmission

    POWER LINE CONDUCTED

    EMI

  • 8/6/2019 Bizarre EMI Incidents

    13/61

    13BIZARRE EMI INCIDENTS

    CommonUtility

    SignalSource 1

    SignalSource 2

    Power Supply

    Power Supply

    SIGNAL LINE CONDUCTED EMI

  • 8/6/2019 Bizarre EMI Incidents

    14/61

    14BIZARRE EMI INCIDENTS

    Weather Deck

    Tx Rx

    14

    ANTENNA TO ANTENNACOUPLING

  • 8/6/2019 Bizarre EMI Incidents

    15/61

    15BIZARRE EMI INCIDENTS

    Upper-deck Cable

    15

    Victim

    TopsideEquipment

    Below Deck

    Above Deck

    Tx

    ANTENNA TO CABLE COUPLING

  • 8/6/2019 Bizarre EMI Incidents

    16/61

    16BIZARRE EMI INCIDENTS

    Victim Victim

    16

    Equipment connected toInterference

    SourceInterference

    Source

    CABLE TO CABLE COUPLING

  • 8/6/2019 Bizarre EMI Incidents

    17/61

    17BIZARRE EMI INCIDENTS

    Could be intriguing

    Might be amusing

    Certainly be educative

    BIZARRE EMI INCIDENTS

  • 8/6/2019 Bizarre EMI Incidents

    18/61

    18BIZARRE EMI INCIDENTS

    Kennedy Space Centre1990sNASA reference publication1374Erroneous signal detectedduring on-pad checkoutPotential threat of launch

    failure

    Incident # 1 Saturn

    launch vehicle

  • 8/6/2019 Bizarre EMI Incidents

    19/61

    19BIZARRE EMI INCIDENTS

    Signal not traced toany known source. Inter-modulationproducts formed at non-

    linear junction onimproperly bondedhinged cable traycovers and chain

    handrails on gantryframe. Spurious signalscapable of engine cutoff command and arm &

    Analysis

    Chain handrails ongantry frame

  • 8/6/2019 Bizarre EMI Incidents

    20/61

    20BIZARRE EMI INCIDENTS 20

    F1

    F2

    F2

    F1

    F1

    F2

    F1

    F2

    F2

    F1F1

    F2

    The badOne !

    Inter Modulation Interference

  • 8/6/2019 Bizarre EMI Incidents

    21/61

    21BIZARRE EMI INCIDENTS 21

    F1

    F2

    F2

    F1F1

    F2

    F1

    F2

    F1

    F2

    F1

    F2

    F1

    F2

    Non-linear

    Junction

    Inter Modulation Interference

  • 8/6/2019 Bizarre EMI Incidents

    22/61

    22BIZARRE EMI INCIDENTS

    Non-linear Junction

    22

    F3 F3 = mF1 +nF2

    Inter Modulation Interference

  • 8/6/2019 Bizarre EMI Incidents

    23/61

    23BIZARRE EMI INCIDENTS

    ITEM 2002, pages 54-

    60. Airplane navigation &communication eqptmalfunction when

    flying through rain.

    Incident # 2 Rain rain goaway

  • 8/6/2019 Bizarre EMI Incidents

    24/61

    24BIZARRE EMI INCIDENTS

    Analysis Static charge on aircraft skin exceeds 100kV

    during rain. High voltage caused arcing between poorlybonded surfaces.

    Resultant broadband noise interferes with

    on-board systems.

    + + + + + + + + + + + + ++ +

    + + + + +

    - - - - - - - - - - - - - - - - - - - - - - - - - - -- -

    + +

    + +

    + +

    + +

    +

    + -

    -

    - -

    - -

    - - - -

    - - - -

    - - - Poorly

    bonded

    surface

  • 8/6/2019 Bizarre EMI Incidents

    25/61

    25BIZARRE EMI INCIDENTS

    Gnd

    V1

    Gnd

    Arc being formed due to non-conducting gap

    Broadband Noise (BBN)

  • 8/6/2019 Bizarre EMI Incidents

    26/61

    26BIZARRE EMI INCIDENTS

    Lightning appearedon Naval aircraft.

    Pilot suffered fromblindness for 10-15secs.

    Cockpit power failure.

    In another flash, allpower restoredwithout any indicationof equipment

    malfunction.

    Incident # 3 Lightningcan and will strike

  • 8/6/2019 Bizarre EMI Incidents

    27/61

    27BIZARRE EMI INCIDENTS

    Hobart, Tasmania Mid 90s New Scientist,

    24th April 1999,page 100

    Residents trappedin garages

    Remote controlsfail

    Incident # 4 Trapped inGarages

  • 8/6/2019 Bizarre EMI Incidents

    28/61

    28BIZARRE EMI INCIDENTS

    USS Carl Vinsonentered harbour

    Navigation radarat same frequencyas remotes

    Malfunction due to

    co-channelinterference

    Analysis

  • 8/6/2019 Bizarre EMI Incidents

    29/61

    29BIZARRE EMI INCIDENTS

    Co-channelinterference due

    to improperallocation of frequencies.

    Later on, coding

    incorporated intoradio operatedcontrols toeliminate

    interference.

    Co-Channel Interference

  • 8/6/2019 Bizarre EMI Incidents

    30/61

    30BIZARRE EMI INCIDENTS

    Incident # 5 Wheel Chair

    MalfunctionEarly 2000IEEE International EMC

    Symposium, Aug 2002A wheel chair suddenlydrove off a subway-platform.Handicapped personinjured critically.

  • 8/6/2019 Bizarre EMI Incidents

    31/61

    31BIZARRE EMI INCIDENTS

    Chair activated due to digital telephone networkfield at 1.89 GHz.Chair tested for radiated susceptibility but onlytill 1 GHz.Manufacturer sentenced for putting unsafeproduct to market.

    Analysis

  • 8/6/2019 Bizarre EMI Incidents

    32/61

    32BIZARRE EMI INCIDENTS

    Sydney, AustraliaEarly 2000Graham Eckersall G4HFG/ W4HFG, 6th Jul 01Radio controlled garagedoors open and closerandomlySome refuse toopen/close at all

    Incident # 6 Garage

    Doors, yet again

  • 8/6/2019 Bizarre EMI Incidents

    33/61

    33BIZARRE EMI INCIDENTS

    6 9 . 7 5 M H z

    9 6 .9 M H z

    Nova broadcasts - 96.9 MHzABC TV sound signal - 69.MHz

    2 7 . 1 5 M H z

    Analysis

  • 8/6/2019 Bizarre EMI Incidents

    34/61

    34BIZARRE EMI INCIDENTS

    HMAS Huon & HMASAnzac

    Early 2000 The Courier Mail, Feb

    1st 2002 Near collision - HMAS

    Huon loses controland veers across thebow of HMAS Anzac

    Incident # 7 A CloseEncounter

  • 8/6/2019 Bizarre EMI Incidents

    35/61

    35BIZARRE EMI INCIDENTS

    Analysis

    Steering gear failureof Huan due to EMIfrom emitters onboard Anzac

    Systems not tested toappropriate standards

    Testing philosophyreviewed for all newlyinducted equipment

  • 8/6/2019 Bizarre EMI Incidents

    36/61

    36BIZARRE EMI INCIDENTS

    EMI/EMC Testing

    Testing as per Mil Std461 C/E mandatory forall equipment.

    COTS equipmentprone to malfunctionin dense EMenvironment onboard.

  • 8/6/2019 Bizarre EMI Incidents

    37/61

    37BIZARRE EMI INCIDENTS

    UK, 2002 www.roxtec.co.in Automatic logger on

    passenger ferry resetswhile passing certainpoint on leavingharbour.

    Always happened inevening, around 2300hrs.

    Never occurred whilearrivin .

    Incident # 8 Ship Data-Log Erased

    http://www.roxtec.co.in/http://www.roxtec.co.in/
  • 8/6/2019 Bizarre EMI Incidents

    38/61

    A l i

  • 8/6/2019 Bizarre EMI Incidents

    39/61

    39BIZARRE EMI INCIDENTS

    AutoData

    Logger

    HotPlates

    SupplyBreaker

    Analysis

    Ferry auto-logger

    Hot plates in

    galley turned off daily at 2300 hrs. Transient in

    common power

    supply causedauto-logger toreset.

    A l i

  • 8/6/2019 Bizarre EMI Incidents

    40/61

    40BIZARRE EMI INCIDENTS

    CADNode

    CopyingMachine

    SupplyBreakerNetworked CAD

    Failures coincidedwith operation of adrawing copyingmachine.

    Switching

    transients injectedonto the ring main.

    Analysis

  • 8/6/2019 Bizarre EMI Incidents

    41/61

    41BIZARRE EMI INCIDENTS

    Yankee Station,Pacific Ocean

    10:52 AM July 29,1967

    Un-commandedrelease of missilefrom own aircraftparked on flight deck.

    134 men killed, 27aircraft lost. Total loss

    72 million dollars.

    Incident # 10 ForrestalDisaster

    A l i

  • 8/6/2019 Bizarre EMI Incidents

    42/61

    42BIZARRE EMI INCIDENTS 42

    Powerful fields at deck level from the shipsradar Incorrectly fitted shielded cable connector.Zuni rocket triggered.

    Analysis

  • 8/6/2019 Bizarre EMI Incidents

    43/61

    43BIZARRE EMI INCIDENTS

    Altincham, UK 1980s Stan Lomax of RTM

    Group ltd, Mar 99 French make chart

    recorder ran at double

    speed on Saturdays

    Incident # 11 Faster,

    faster

    A l i

  • 8/6/2019 Bizarre EMI Incidents

    44/61

    44BIZARRE EMI INCIDENTS

    More TVs and radios inuse on Saturdays

    Second harmonic

    currents injected intothe mains Synchronous motors in

    chart recorders

    responds to 100 Hzdistortion Starts running twice as

    fast

    Analysis

    N = 120 f /P

    H i

  • 8/6/2019 Bizarre EMI Incidents

    45/61

    45BIZARRE EMI INCIDENTS

    Harmonics

    Harmonics aremultiples of theprimary frequency.

    Can causeinterference wellbeyond the expectedband of operation.

  • 8/6/2019 Bizarre EMI Incidents

    46/61

    46BIZARRE EMI INCIDENTS

    Netherly & Balbeggie,Scotland

    Mid 1990s 7th International

    Conference on Harmonicsand quality of Power (IEEE),Oct 1996

    Payphones too noisy touse.

    Rolling pictures on TV sets. Ringing on the supply to

    fluorescent lighting circuits.

    Incident # 12 No TV, notalk, only walk

    A l i

  • 8/6/2019 Bizarre EMI Incidents

    47/61

    47BIZARRE EMI INCIDENTS

    Two new oil pumpingstations installed.

    33 KV power lines of induction drivespassing close to

    residential areas. Higher orderharmonics (beyond100th) causing

    interference.

    Analysis

  • 8/6/2019 Bizarre EMI Incidents

    48/61

    48BIZARRE EMI INCIDENTS

    Europe, 1990sCompliance Engineering

    Magazines European editionSept/Oct 1994. Monitor/defibrillatorattached to heart patientshut down every timetechnicians used radiotransmitter for advice.

    Patient dies.

    Incident # 13 Medicaladvice causes death?

    A l i

  • 8/6/2019 Bizarre EMI Incidents

    49/61

    49BIZARRE EMI INCIDENTS

    Long range radio antenna fitted on

    ambulance. Ambulance roof changed from metal tofiberglass

    Significant reduction in EM shielding. Reduced shielding coupled with strongradiated power caused malfunction of equipment.

    Analysis

  • 8/6/2019 Bizarre EMI Incidents

    50/61

    50BIZARRE EMI INCIDENTS

    SHIELDING MODEL

    Incident Energy

    Reflected Energy

    Shield

    Absorptive Region

    Penetrating Energy

    I id # 14 I f

  • 8/6/2019 Bizarre EMI Incidents

    51/61

    51BIZARRE EMI INCIDENTS

    New JerseyEarly 80s

    Doug McKean, [email protected] infant deaths inIntensive Care SectionLate at night, the alarms onbabies monitors go off Annoyed nurses turns off alarm

    Incident # 14 InfantMortality

    Analysis

  • 8/6/2019 Bizarre EMI Incidents

    52/61

    52BIZARRE EMI INCIDENTS

    Nearby TV transmitter allowed to increasedoutput wattage after midnight by FCC.Radiated noise coupled to un-shielded alarmcables.

    Alarm

    Nurse Stn

    Cable

    Analysis

    Incident # 15 Stop that

  • 8/6/2019 Bizarre EMI Incidents

    53/61

    53BIZARRE EMI INCIDENTS

    Incident # 15 Stop thatTrain

    EuropeLate 90s

    Jennifer Cortese,Melbourne, Dec 2000Certain type of locomotive passing by

    radio station brakessuddenly. Oh comeon notagain!!!

    Analysis

  • 8/6/2019 Bizarre EMI Incidents

    54/61

    54BIZARRE EMI INCIDENTS

    Cables of temperaturesensor within tractionmotors not screened.Radio signals beingpicked up by sensorscausing the MCB to open.Modification veryexpensive as sensorswere mounted withinwindings of motors.

    Analysis

    Incident # 16 Cable TV

  • 8/6/2019 Bizarre EMI Incidents

    55/61

    55BIZARRE EMI INCIDENTS

    Incident # 16 Cable TV,No TV

    Set top box placed ontop of TV disruptspicture after 2-5minutes.Interference evenwhen no cablesconnected.All efforts bydesigners in vain.

    A l i

  • 8/6/2019 Bizarre EMI Incidents

    56/61

    56BIZARRE EMI INCIDENTS

    SETTOP BOXInterference due toMagnetic fields fromstereo speakers.Similar problemswith all metallicobjects.

    Resolved byremoving Set-top boxfrom vicinity.

    Analysis

    I id t # 17 C k

  • 8/6/2019 Bizarre EMI Incidents

    57/61

    57BIZARRE EMI INCIDENTS

    Incident # 17 Car park security

    PortsmouthEaster 2001Anne Cameron, Alenia

    Marconi Systems, 6th Jul01Cars parked insideshopping mall parking lotnot unlocking.Cars getting locked assoon as they are

    unlocked.

    I id t # 18 B th

  • 8/6/2019 Bizarre EMI Incidents

    58/61

    58BIZARRE EMI INCIDENTS

    Incident # 18 BreathAnalysis

    USARecentFrom an Ex-copFalse indications frombreath analyzer.People charged finedespite being innocent.

    Anal sis

  • 8/6/2019 Bizarre EMI Incidents

    59/61

    59BIZARRE EMI INCIDENTS

    EM radiations from video surveillancesystem interfere with car central locking andsecurity systems.Interference from the radio handsets causedmalfunctioning of breath analyzer

    Analysis

  • 8/6/2019 Bizarre EMI Incidents

    60/61

    60BIZARRE EMI INCIDENTS

    An Insight into the futurePossible article in Defence Review

    Weekly, 2050

    NATO Exercise Tech Savvy Forces

    FailsGreat chaos as large portion of COTSequipment malfunctioned.

    Attacking forces takeover, despite being on foot, armed only with vintage

    equipment & communicating by shouting.

  • 8/6/2019 Bizarre EMI Incidents

    61/61

    Want to know more . . .