black fpm fkm sheet product - j-flex · thermogravimetrie nach iso 11358-1 i thermogravimetric...

4
Material Data Sheet Units 1 & 2, London Road Business Park, Retford, Nottinghamshire, DN22 6HG, United Kingdom tel: +44 (0) 1777 712400 fax: +44 (0) 1777 712409 email: sales@j-flex.com web: www.j-flex.com J-Flex is the trading name of Clockpress Ltd - Registered in England & Wales No.02448048. Issue Date Innovative Rubber Solutions PROPERTY TEST RESULTS TEST METHOD Type ‘A’ Type FPM/FKM ISO 1629 Hardness 75 (+/-5) Shore ‘A’ ISO 7619-1 Specific Gravity / Density 1.84 g/cm 3 ISO 1183/2781 Tensile Strength 7 N/mm 2 ISO 37 Elongation @ Break > 200% ISO 37 Tear Strength 4.2 N/mm ISO 34-1, A Compression Set: - Test Condition: 24hrs @200˚C - Compression Rate: 25% 36% ISO 815-1:2016 Method ‘A’ Temperature Resistance -15°C to +250°C Information provided as a Guideline Features: * FPM / FKM 68% Fluorine Content * Bisphenol Cured * Post Cured * Applicable to +275°C for a short time Available in thicknesses: 0.5mm to 25mm 0.5mm to 6mm - Rolls: 1200mm wide x 10m long 8mm & 10mm - Rolls: 1200mm wide x 5m long Over 10mm thick – plates: 2000mm x 1000mm FLUOR-A-COM ® is a Registered Trade Mark of J-Flex See official Test Report attached BLACK FPM / FKM SHEET PRODUCT PAH / PAK COMPLIANT

Upload: others

Post on 02-Nov-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BLACK FPM FKM SHEET PRODUCT - J-Flex · Thermogravimetrie nach ISO 11358-1 I thermogravimetric analysis acc. to ISO 11358-1 künstliche Alterung nach DIN 53 508 I accelerated ageing

Material Data Sheet

Units 1 & 2, London Road Business Park, Retford, Nottinghamshire, DN22 6HG, United Kingdom tel: +44 (0) 1777 712400 fax: +44 (0) 1777 712409 email: [email protected] web: www.j-flex.com

J-Flex is the trading name of Clockpress Ltd - Registered in England & Wales No.02448048. Issue!21!!! Date!Kvmz!312:

Innovative Rubber Solutions

PROPERTY

TEST RESULTS

TEST METHOD Type

‘A’ Type FPM/FKM

ISO 1629

Hardness

75 (+/-5) Shore ‘A’

ISO 7619-1

Specific Gravity / Density

1.84 g/cm3

ISO 1183/2781

Tensile Strength

7 N/mm2

ISO 37

Elongation @ Break

> 200%

ISO 37

Tear Strength

4.2 N/mm

ISO 34-1, A

Compression Set: - Test Condition: 24hrs @200˚C - Compression Rate: 25%

36%

ISO 815-1:2016

Method ‘A’

Temperature Resistance

-15°C to +250°C

Information provided as a Guideline

Features: * FPM / FKM 68% Fluorine Content

* Bisphenol Cured

* Post Cured

* Applicable to +275°C for a short time

Available in thicknesses: 0.5mm to 25mm 0.5mm to 6mm - Rolls: 1200mm wide x 10m long 8mm & 10mm - Rolls: 1200mm wide x 5m long

Over 10mm thick – plates: 2000mm x 1000mm

FLUOR-A-COM® is a Registered Trade Mark of J-Flex See official Test Report attached

BLACK FPM / FKM SHEET PRODUCT

PAH / PAK COMPLIANT

Page 2: BLACK FPM FKM SHEET PRODUCT - J-Flex · Thermogravimetrie nach ISO 11358-1 I thermogravimetric analysis acc. to ISO 11358-1 künstliche Alterung nach DIN 53 508 I accelerated ageing

140817063 Istwerte / actual values

Prüfplatte / test slab

2mm FKM

Härte/ hardness Anlieferung I as received condition 72 Shore A

Dichte / density 1,84 g/cm³

Zugversuch nach DIN 53 504 I tensile test acc. to DIN 53 504

Reiẞfestigkeit / tensile strength Anlieferung I as receivedcondition 7,4 N/mm²

Reiẞdehnung I elongation at break Anlieferung I as receivedcondition 218 %

Spannungswert bei 100% Dehnung I stress at 100% elongation

Anlieferung I as received condition 3,5 N/mm²

Weitereiẞwiderstand nach ISO 34-1 I tear strength acc. to ISO 34-1

Weiterreiẞwiderstand I tear strength Anlieferung I as received condition

4,2 N/mm

flüchtige Bestandteilevolatiles

1,7 %

pyrolysierbare Bestandteile pyrolyzable ingredients

63,1 %

oxidierbare Bestandteileoxidizable ingredients 17,3 %

anorganischer Rest inorganic rest

Ascherest residual 17,9 %

Druckverformungsrestprüfung Verf. A nach DIN ISO 815-1 I compression set method Aacc. to DIN ISO 815-1

DVR / CS 23h / 100°C 21 %

DVR / CS 24h / 150°C 21 %

DVR / CS 24h / 200°C 36 %

DVR / CS

24h / 250°C 71

%

DVR / CS

24h / 275°C 92 %

DVR / CS

168h / 200°C 66 %

DVR / CS

168h / 275°C 115 %

Volumenäderung change of volume

künstliche Alterung accelerated ageing 168h / 250°C

-12,2 %

Masseänderung change of weight - 8,1 %

Härteänderung change of hardness 10 Shore A

Reiẞfestigkeit

tensile strength 8,3

N/mm²

Ӓnderung der Reiẞfestigkeit

change of tensile strength 13

%

Reiẞdehnung

elongation at break 166

%

Ӓnderung der Reiẞdehnung

change of elongation at break -24

%

Spannungswert bei 100% Dehnung

stress at 100% elongation 5,9

N/mm²

Ӓnderung des Spannungswertes bei

100% Dehnung

change of stress at 100% elongation 70

%

Anlieferung I as receivedcondition

Thermogravimetrie nach ISO 11358-1 I thermogravimetric

analysis acc. to

ISO 11358-1

künstliche Alterung nach DIN 53 508 I accelerated ageing acc. to DIN 53 508 168h / 250°C

Test completed by O-Ring Prüflabor Richter GmbH - 31.08.2017

Certificate No. RS 27920 Approved to BS EN ISO 9001:2015

Tina
Typewritten Text
Tina
Typewritten Text
FPM/FKM TEST REPORT
Tina
Typewritten Text
Tina
Typewritten Text
Page 1
Tina
Typewritten Text
Page 3: BLACK FPM FKM SHEET PRODUCT - J-Flex · Thermogravimetrie nach ISO 11358-1 I thermogravimetric analysis acc. to ISO 11358-1 künstliche Alterung nach DIN 53 508 I accelerated ageing

Volumenänderungchange of volume

Masseänderung change of weight

Härteänderung change of hardness

-20,6 %

-16,6

%

17

Shore A

Reißfestigkeit 6,2

N/mm²

tensile strength

Änderung der Reißfestigkeit künstilche Alterung -17 %

change of tensile strength accelerated ageing Reißdehnung

168h / 275°C 91

% elongation at break

Änderung der Reißdehnung

-58

% change of elongation at break

Spannungswert bei 100% Dehnung stress at 100% elongation -

Ӓnderung des Spannungswertes bei

N/mm²

100% Dehnung - %change of stress

at 100% elongation

Volumenänderung -1,2 % change of volume Masseänderung change of weight

Härteänderung change of hardness

-0,6 %

2 Shore A

Reißfestigkeit 7,8 N/mm² tensile strength

Änderung der Reißfestigkeit change of tensile strength

5 %

Reißdehnung

IRM ÖI 901

elongation at break

IRM oil 901 227

%

Änderung der

Reißdehnung

change of elongation at break

Spannungswert bei 100% Dehnung stress at 100%

Ӓnderung des Spannungswertes bei 100% Dehnung

change of stress at 100% elongation

4

%

3,6

N/mm²

3 %

0°C

Volumenänderung 0,7 %

change of volume

Masseänderung

change of weight

Härteänderung change of hardness Reißfestigkeit tensile strength

0,3 %

1 IRHD

7,6

N/mm²

Ӓnderung der Reißfestigkeit3 %

change of tensile strength

IRM ÖI 903 IRM oil 903

Reißdehnung

72h / 100°C

72h / 100°C

233 %

elongation at break

Änderung der Reißdehnung

change of elongation at break 7 %

Spannungswert bei100% Dehnung 3,3 N/mm²

stress at 100% elongation

Änderung des Spannungswertes bei 100% Dehunung -4

%

change of stress at 100% elongation

140817063 Istwerte / actual values

Prüfplatte / test slab 2mm FKM

künstliche Alterung nach DIN 53 508 I accelerated ageing acc. to DIN 53 508 168h / 250°C

IRM ÖI 901 nach DIN ISO 1817 / IRM oil 901 acc. to DIN ISO 1817 72h / 100°C

IRM ÖI 903 nach DIN ISO 1817 / IRM oil 903 acc. to DIN ISO 1817 72h / 100°C

Tina
Typewritten Text
Tina
Typewritten Text
Tina
Typewritten Text
Tina
Typewritten Text
Page 2
Tina
Typewritten Text
Page 4: BLACK FPM FKM SHEET PRODUCT - J-Flex · Thermogravimetrie nach ISO 11358-1 I thermogravimetric analysis acc. to ISO 11358-1 künstliche Alterung nach DIN 53 508 I accelerated ageing

Volumenänderungchange of volume

Masseänderung change of weight

Härteänderung change of hardness

9.0

%

4.0

%

- 6

Shore A

Reißfestigkeit 5,2

N/mm²

tensile strength

Änderung der ReißfestigkeitFAM A -2 9

change of tensile strength Reißdehnung

24h / 23°C

19 0

% elongation at break

Änderung der Reißdehnung -1 3 % change of elongation at break

Spannungswert bei 100% Dehnung

stress at 100% elongation 2.7

Ӓnderung des Spannungswertes bei

N/mm²

100% Dehnung -22 %

%

change of stress at 100% elongation

Volumenänderung 2 3 , 9 % change of volume

Masseänderung change of weight

Härteänderung change of hardness

1 0 , 3 %

- 1 6 Shore A

Reißfestigkeit 3, 5 N/mm² tensile strength

Änderung der Reißfestigkeit change of tensile strength

- 5 3 %

Reißdehnung

FAM B

elongation at break

147

%

Änderung

der

Reißdehnung

change of elongation at break

Spannungswert bei 100% Dehnung stress at 100% elongation

Ӓnderung des Spannungswertes bei 100% Dehnung

change of stress at 100% elongation

-33

3

%

2 , 3

N/mm²

- 3 %

0°C S

Durchgangswiderstand 29,7 E+09

Volume resistancespezifischer Durchgangswiderstand

Volume resistivity

Oberflächenwiderstand Surface resistance

spezifischer Oberflächenwiderstand

Surface resistivity

3717 E+09

537,2 E+09

18566 E+09

24h / 23°C

140817063 Istwerte / actual values

Prüfplatte / test slab 2mm FKM

FAM A nach DIN ISO 1817 / acc. to DIN ISO 1817 24h / 23°C

FAM B nach DIN ISO 1817 acc. to DIN ISO 1817 24h / 23°C

spezifischer Durchgangswiderstand / spezifischer Oberflächernwiderstand DIN IEC 60093 volume resistivity and surface resistivity DIN IEC 60093

( )RD Ω

σ ( )Ω

( ) RO

( xcm)ρ

Ω

Ω

Units 1 & 2, London Road Business Park, Retford, Nottinghamshire, DN22 6HG, United Kingdom tel: +44 (0) 1777 712400 fax: +44 (0) 1777 712409 email: [email protected] web: www.j-flex.com

J-Flex is the trading name of Clockpress Ltd - Registered in England & Wales No.02448048. Issue!21!!! Date!Kvmz!312:

Innovative Rubber Solutions

Tina
Typewritten Text
Tina
Typewritten Text
Tina
Typewritten Text
Page 3
Tina
Typewritten Text