bme 273 fetal stabilizer for intrauterine surgery
DESCRIPTION
BME 273 Fetal Stabilizer for Intrauterine Surgery. Michael Dinh Advisor: Dr. Joseph Bruner. Spina Bifida. Spina Bifida affects approximately 1 out of every 1,000 newborns in the U.S - PowerPoint PPT PresentationTRANSCRIPT
BME 273BME 273Fetal Stabilizer for Fetal Stabilizer for
Intrauterine SurgeryIntrauterine Surgery
Michael DinhMichael Dinh
Advisor: Dr. Joseph BrunerAdvisor: Dr. Joseph Bruner
Spina BifidaSpina Bifida
Spina Bifida affects approximately 1 Spina Bifida affects approximately 1 out of every 1,000 newborns in the out of every 1,000 newborns in the U.SU.S
Each year in the US about 4,000 Each year in the US about 4,000 pregnancies are affected by spina pregnancies are affected by spina bifida and anencephaly, an average bifida and anencephaly, an average of 11 pregnancies per day of 11 pregnancies per day
Vanderbilt UniversityVanderbilt University
165 cases of spina 165 cases of spina bifida repairbifida repair• Age range of infants Age range of infants
19-30 weeks19-30 weeks
Mean operating Mean operating time is about 87 time is about 87 minmin• Ranges from 62-Ranges from 62-
131 min131 min
Dr. Bruner Vanderbilt University
MyelomeningoceleMyelomeningocele
Defect in the spinal Defect in the spinal columncolumn
Protrusion of spinal Protrusion of spinal cord membrane, cord membrane, spinal cord, and nerve spinal cord, and nerve rootsroots
Bathing of developing Bathing of developing spinal cord with spinal cord with amniotic fluid results amniotic fluid results in progressive in progressive neurological injuryneurological injury
Design ObjectiveDesign Objective
Design a fetal Design a fetal stabilizer to assist stabilizer to assist in surgeryin surgery• Hold fetus steady Hold fetus steady
while providing an while providing an opening for opening for operationoperation
Dr. Bruner Vanderbilt University
Device SpecificationDevice Specification
LightweightLightweight• Material: light weight polymer or Material: light weight polymer or
stainless steelstainless steel Length of device < 20 cmLength of device < 20 cm
• Large size involve stability problemsLarge size involve stability problems Flanged opening at top curved to Flanged opening at top curved to
keep opening sealedkeep opening sealed
Fetal DataFetal Data
19 week old fetus19 week old fetus• 6 inches head to end6 inches head to end• Weight about 8.5 ouncesWeight about 8.5 ounces
http://www.babycenter.com/mybabycenter/119.html
Current and Future OutlookCurrent and Future Outlook
No known device that serves such No known device that serves such functionfunction
Design which leads to a prototypeDesign which leads to a prototype• Feasible in size and not cumbersome in Feasible in size and not cumbersome in
useuse