Non spillable
With use of an absorbed electrolyte technology, electrolyte is absorbed to the positive plates & negative
plates, an d the separators, coupled with the use of special sealing epoxies, and long sealing paths for
posts, BOSFA VRLA batteries have exceptional leak resistance, which ensures batteries could be
operated in a wide range of applications.
Explosion Proof
With advance safety valve system and special filter, bosfa battery could prevent the chance of battery
explosion and ensure complete safety in normal use.
Sealed and Maintenance free operation
There is no corroslve gas generation during normal use and no need to check the specific gravity of the
electrolyte or additional water adding during batterys service life.
High Quality and high Reliability
BOSFA VRLA battery has stable and reliable capacity. The battery can withstand overcharge, over
discharge, vibration, and stock. To assure this high quality and reliability, the batteries are 100% tested
on production line for voltage, capacity, sealing condition and the safety valve are 100% visually
inspected before the final assembly process?
Exceptional Deep Discharge Recovery Performance
With use of high density manufacturing materials and technology, Bosfa VRLA batteries have
exceptional deep discharge recovery and charge acceptance, even after deep or prolonged discharge.
Low self discharge
With the advantages of lead calcium grids alloy and high purity materials, bosfa VRLA batteries could be
stored for a certain long periods of time without recharge.
ABS Containers and Covers
With use of case resin both UL94Hb and UL94V o containers and covers, high impact and fire
resistanve performance could be adopted with most bosfas range of products.
Flexibility Design
Bosfa battery could be used in series and or parallel to give wide range of voltages and capacities for
variety of applications.
-
8/4/2019 BOSFA VRLA Battery Performance
2/3
Characteristics
Discharge
End discharge voltage
To maintain discharge safely and maximize battery life, ending discharge voltage MUST NOT LESS THAN
the data showed in figure below.
Discharge current End Discharge voltage
Up to 0.10CA 1.75
0.11 to .20CA 1.70
.21 to .30CA 1.67
.31 to 1.00CA 1.60
Above 1.10CA 1.30
Battery discharge characteristics:
The discharge capacity of battery is dependent on the discharge rate being used and amblent
temperature, battery output capacity is reduced when it is discharge at a higher current. At a higher
temperature, the capacity of battery increase and conversely at a lower temperature, the capacity of
battery decrease.
Discharging
Charging method:
Correct charging is one of the most important factors in consideration of using valve regulated lead acid
batteries. Battery performance and service life will be directly affected by the charging methods.
Recommended methods of charging is constant voltage charging. It is necessary to precisely control of
actual voltage in order to ensure that it is within the limits advised.
standby service: 2.25-2.30 vpc at 25 c/77 F cycle service: 2.23-2.45vpc at 25 c/77 F
It is suggested that the initial current be set within 0.3CAMPS.
Note:
It is necessary to ensure that the voltage is correctly set. The charging voltage set too high will increase
the corrosion of the positive plates causing loss of capacity and ultimately shorten the life of the battery.
-
8/4/2019 BOSFA VRLA Battery Performance
3/3
Effect of temperature on charging voltage as temperature rises, electrochemical activity in the battery
increases. Similarly, as temperature fails, electrochemical activity decrease. Therefore as temperature
rises charging voltage should be reduced to prevent overcharge as temperature falls charging voltage
should be increase to avoid undercharge. To optimize service life, use of a temperature compensated
charger is recommended. The recommend compensation factor for bosfa vrla batteries is 3mv/c cell and
4mv/c cell. The standard center point for temperature compensation is 20 c/68F.
Battery storage:
General storage conditions:
The battery should be stored under the following conditions.
Low humidity 5 to 104 F (-15 to 40 C) Clean, dry and avoid direct sunlight
Handling precautions
Never charge the battery in a sealed container Never disassemble the battery Never short battery terminals. Never incinerate batteries, for they may explode. Do not press and/ or bend the terminals, or over heat them. Do not install old and new batteries together, neither use batteries of different types. Do not dispose of with household waste. Use the specification charger for battery, and follow the charging instructions correctly. Charge the batteries between the temperature 0*C/32*F to 45 C/113F. Position batteries securely, protecting them from abnormal shocks or vibration. Keep sufficient space (10mm minimum) between batteries in a cool and well ventilated place. The ambient temperature must remain between -20 C/4 F to 40 C/104 F in storage time. Recharge the batteries at least every 6 months during storage.