bottling report cce10
DESCRIPTION
Vibration Report CCETRANSCRIPT
Vibration Report
for the
Month of May 2010
Advanced Monitoring Service
55 Leedham Street Suite 3-6 South Attleboro Ma. 02703 774-219-9947
Enclosed is a current report of the data collected during our visit to CCE Elmsford, NY on June23, 2005. This report will give you an overview of all data collected, the recommended action ,and their priority levels. Please feel free to contact our office with any questions or concernsyou may have regarding this report or the services you received.
June 23, 2005
CCE Bottling Company of New York111 View Park DriveElmsford, NY 10523
Attention : Mr. Michael P. Rose
Subject : Monthly Readings for the PdM Program
Dear Mike,
Sincerely,
Edward A. BartnikowskiReliability Consultant
Advanced Monitoring Service
55 Leedham Street Suite 3-6 South Attleboro Ma. 02703 774-219-9947
Alarm Priority Codes
Critical
High
Low
Emergency Situation, Immediate Action Needed
Repair within the Month or Next Scheduled Shutdown
Monitor more Frequently
Alarm Report SummaryMACHINE ALARM PAGE PROBLEM
#3 Line Vacuum Pump CRITICAL 11 Lube
#7 Ammonia Compressor CRITICAL 5 Alignment
#1 Line Booster Pump CRITICAL 7 Balance
#2 Line Vacuum Pump CRITICAL 8 Loose
#3 Line Booster Pump HIGH 9 Lube
#2 Fridge Compressor HIGH 2 Mounting
#1 Air Compressor HIGH 3 Alignment
#3 Line Prod. Pump HIGH 10 Lube
#9 Ammonia Compressor LOW 4 Belt Alignment
#5 Ammonia Compressor LOW 1 Alignment
#1 Line Main Drive LOW 6 Electrical
DATE :
March 25,2010
COMPANY :
East Hartford
AREA :
Can Line
PRIORITY :
CRITICAL
PROBLEM STATEMENT :
INSPECT INPUT BEARING FOR PROPER MOUNTING AND WEAR
MACHINE NAME :
Seamier
ITEM NUMBER :
MACHINE DRAWING :
FINDINGS :
The spectrum on the motor indicatesan high nonsynchours peaks in the radialposition which is a indication of a bearingproblem.
RECOMMENDATIONS :
Recommend inspecting unit forproper wear and replace or rebuild inputbearing housing as needed. .
PAGE : 7
M1AM1RM1V
M2AM2RM2V
P1AP1RP1V
Before rebuild
After rebuild
DATE :
June 23, 2005
COMPANY :
East Hartford
AREA :
Ammonia room
PRIORITY :
LOW
PROBLEM STATEMENT :
INSPECT BELTS FOR PROPER WEAR AND FIT
MACHINE NAME :
#2 Ammonia Compressor
ITEM NUMBER :
MACHINE DRAWING :
FINDINGS :
The spectrum on the motor indicatesan increase in 1x belt with no harmonics,which is a indication of a belt condition.
RECOMMENDATIONS :
Recommend inspecting belt forproper wear and fit, also inspect sheaves forwear and replace as needed.
PAGE : 3
C1AC1RC1V
C2AC2RC2V
M1AM1RM1V
M2AM2RM2V
Before Belt alignment
After Belt Alignment
DATE :
Oct. 27, 2006
COMPANY :
East Hartford
AREA :
Ammonia Room
PRIORITY :
HIGH
PROBLEM STATEMENT :
ENSURE PROPER ELECTRICAL
MACHINE NAME :
#2 Ammonia Compressor
ITEM NUMBER :
MACHINE DRAWING :
FINDINGS :
The Spectrums on the motorindicates a high 1940 Hz peak with sidebands, which is a indication of a statorproblem.
RECOMMENDATIONS :
Recommend rewinding motor.
PAGE : 9
C1AC1RC1V
C2AC2RC2V
M1AM1RM1V
M2AM2RM2V
Before motor was rewound
After motor rewind
DATE :
June 23, 2005
COMPANY :
ABC Company
AREA :
Line #3
PRIORITY :
CRITICAL
PROBLEM STATEMENT :
ENSURE PROPER UNIT ALIGNMENT
MACHINE NAME :#3 Can Line
Vacuum Pump
ITEM NUMBER :
MACHINE DRAWING :
FINDINGS :
The Spectrum on the pump indicatesa high 1xfr an 2xfr , which is a indication ofa coupling problem.
RECOMMENDATIONS :
Recommend ensuring propercoupling wear replace as needed, realignmotor and pump.
PAGE : 12
M1AM1RM1V
M2AM2RM2V
P1AP1RP1V
P2AP2RP2V
Spectrum Before Alignment
1xfr
2xfr
1xfr
2xfr
After coupling use replaced and realigned
Types of equipment canbe tested.
Ammonia Compressor
Washer Pumps
Air Compressors