bridgeport high school canopy … · a101 floor plans a601 sections, ... bridgeport high school...

4
A.F.F. BRK'T BLKHD BTM. CLG. C.J. CONT. DS DWGS. E.J. EH ELEC. EP EXIST. EXP. EXT. FD F.E.C. FIN. GYP. BD. HT. INT. JT. MFR MECH. MET. MTD. N.I.C. O.C. OPP. PTD. PT ABOVE FINISHED FLOOR BRACKET BULKHEAD BOTTOM CEILING CONTROL JOINT CONTINUOUS DOWN SPOUT DRAWINGS EXPANSION JOINT ELECTRIC HEATER - SEE MECH. DWGS. ELECTRICAL ELEC. PANEL - SEE ELEC. DWGS. EXISTING EXPOSED EXTERIOR FLOOR DRAIN FIRE EXTINGUISHER CABINET FINISHED GYPSUM BOARD HEIGHT INTERIOR JOINT MANUFACTURER MECHANICAL METAL MOUNTED NOT IN CONTRACT ON CENTER OPPOSITE PAINTED PRESSURE TREATED DRAWING INDEX BRIDGEPORT HIGH SCHOOL CANOPY REPLACEMENT HARRISON COUNTY SCHOOLs BRIDGEPORT, WEST VIRGINIA FILE MSES 16-1011 DATE 8/10/2016 REVISIONS MULTI-PRIME CONTRACTORS: CONTRACT A - GENERAL CONTRACTOR CONTRACT B - CANOPY CONTRACTOR 1. ALL DIMENSIONS ARE NOMINAL TO FINISHED MATERIALS U.N.O. 2. VERIFY EXIST. CONDITIONS & DIMENSIONS IN FIELD BEFORE PROCEEDING WITH CONSTRUCTION. IMMEDIATELY REPORT ANY DISCREPANCIES TO ARCHITECT. ELECTRICAL: (BY OWNER, PROVIDED FOR REFERENCE ONLY) E101 ELECTRICAL DEMOLITION & LIGHTING PLAN ARCHITECTURAL: A101 FLOOR PLANS A601 SECTIONS, DETAILS & SCHEDULES AUGUST 10, 2016 BRIDGEPORT HIGH SCHOOL CANOPY REPLACEMENT HARRISON COUNTY SCHOOLS BRIDGEPORT, WEST VIRGINIA PROJECT LOCATION VICINITY MAP N.T.S. PROJECT SITE MAP N.T.S. PROJECT LOCATION GENERAL NOTES: ABBREVIATIONS: SIM. SQ. STL. TBD T.O.M. TWU TS TYP. U.N.O. V.I.F. W/ WD. SIMILAR SQUARE STEEL TO BE DETERMINED TOP OF MASONRY THROUGH - WALL UNIT - SEE MECH. DWGS. TUBE STEEL TYPICAL UNLESS NOTED OTHERWISE VERIFY IN FIELD WITH WOOD

Upload: phamanh

Post on 01-May-2018

218 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: BRIDGEPORT HIGH SCHOOL CANOPY … · a101 floor plans a601 sections, ... bridgeport high school canopy replacement bridgeport, west virginia ... bridgeport high school canopy replacement

A.F.F.BRK'TBLKHDBTM.CLG.C.J.CONT.DSDWGS.E.J.EHELEC.EPEXIST.EXP.EXT.FDF.E.C.FIN.GYP. BD.HT.INT.JT.MFRMECH.MET.MTD.N.I.C.O.C.OPP.PTD.PT

ABOVE FINISHED FLOORBRACKETBULKHEADBOTTOMCEILINGCONTROL JOINTCONTINUOUSDOWN SPOUTDRAWINGSEXPANSION JOINTELECTRIC HEATER - SEE MECH. DWGS.ELECTRICALELEC. PANEL - SEE ELEC. DWGS.EXISTINGEXPOSEDEXTERIORFLOOR DRAINFIRE EXTINGUISHER CABINETFINISHEDGYPSUM BOARDHEIGHTINTERIORJOINTMANUFACTURERMECHANICALMETALMOUNTEDNOT IN CONTRACTON CENTEROPPOSITEPAINTEDPRESSURE TREATED

DRAWING INDEX

BRIDGEPORTHIGH SCHOOL

CANOPYREPLACEMENT

HARRISON COUNTY SCHOOLsBRIDGEPORT, WEST VIRGINIA

FILE MSES 16-1011

DATE 8/10/2016

REVISIONS

MULTI-PRIME CONTRACTORS:

CONTRACT A - GENERAL CONTRACTORCONTRACT B - CANOPY CONTRACTOR

1. ALL DIMENSIONS ARE NOMINAL TO FINISHEDMATERIALS U.N.O.

2. VERIFY EXIST. CONDITIONS & DIMENSIONS INFIELD BEFORE PROCEEDING WITHCONSTRUCTION. IMMEDIATELY REPORT ANYDISCREPANCIES TO ARCHITECT.

ELECTRICAL: (BY OWNER, PROVIDED FOR REFERENCE ONLY)

E101 ELECTRICAL DEMOLITION & LIGHTING PLAN

ARCHITECTURAL:

A101 FLOOR PLANSA601 SECTIONS, DETAILS & SCHEDULES

AUGUST 10, 2016

BRIDGEPORT HIGH SCHOOLCANOPY REPLACEMENTHARRISON COUNTY SCHOOLSBRIDGEPORT, WEST VIRGINIA

PROJECT LOCATION

VICINITY MAPN.T.S.

PROJECT SITE MAPN.T.S.

PROJECT LOCATION

GENERAL NOTES:ABBREVIATIONS:

SIM.SQ.STL.TBDT.O.M.TWUTSTYP.U.N.O.V.I.F.W/WD.

SIMILARSQUARESTEELTO BE DETERMINEDTOP OF MASONRYTHROUGH - WALL UNIT - SEE MECH. DWGS.TUBE STEELTYPICALUNLESS NOTED OTHERWISEVERIFY IN FIELDWITHWOOD

Page 2: BRIDGEPORT HIGH SCHOOL CANOPY … · a101 floor plans a601 sections, ... bridgeport high school canopy replacement bridgeport, west virginia ... bridgeport high school canopy replacement

C

D

E

F

1 2 3 4 5 6 7

B

A

G

H

REMOVE EXISTINGDAMAGED TS COLUMN INIT'S ENTIRETY - TYP. (1)

REMOVE EXISTING TSCOLUMNS - CUT OFF MIN.4" BELOW SLAB - TYP. (4)

REMOVE EXISTING TSCOLUMNS - CUT OFF MIN.4" BELOW SLAB - TYP. (4)

REMOVE EXISTINGCANOPY & FRAMING IN ITSENTIRETY

REMOVE EXISTINGCANOPY & FRAMINGIN ITS ENTIRETY

10' -

8"

10' -

8"

11' -

0"

9' -

0"

11' -

0"

10' -

8"

10' -

8"

9' - 0" 11' - 0" 11' - 0" 11' - 0" 11' - 0" 11' - 0" 8' - 11 3/4"

EXISTING CONCRETESIDEWALK TO REMAIN

EXISTING BUILDING

REMOVEDOWNSPOUTS TOGRADE LEVEL

EXIST. RAMPTO REMAIN

EXISTING TS 4x4 COLUMNS TO REMAIN -TYP. (17). CUT & REMOVE TOPS OFCOLUMNS SO THEY ARE 8'-0" HIGH,EXCEPT FOR COLUMNS D2, E1, & E2WHICH SHALL REMAIN AT EXISTINGHEIGHT OF 10'-9"±

FA

CE

OF

BU

ILD

ING

C

D

E

F

1 2 3 4 5 6 7

1

A301

1

A301

2

A301

CONTRACT B - BID NO. 1:INTERNAL "FAN BEAM" WITHIN STRUCT.INSULATED PANELS - TYP. @ EA. LIGHTFIXTURE LOCATION TO BE USED AS ELEC.CONDUIT - TYP.CONTRACT B - BID NO. 2:OWNER TO PROVIDE UNISTRUT FRAMING ANDCONDUIT TO LIGHT FIXTURES

2' - 0" TO OF FAN BEAM (TYP.)

(TYP.)

4' - 0"

BEAMS AND CONNECTIONS TOTS COLUMNS BY CANOPY MFR.

LINE OF 4' WIDE STRUCTURALINSULATED ROOF PANELS - TYP.

EXISTING TS 4x4COLUMN (TYP.)

CL

EXIST. COLUMN (TYP.)

(2)

TS

4X

8

(2)

TS

4X

8

(2) TS 4X8

(2) TS 4X8

DS DS

DS

DS

DS

6' -

0"

6' -

0"

12' - 0" 12' - 0" 12' - 0" 12' - 0" 6' - 0"

SURFACE MOUNTED LIGHTFIXTURES BY OWNER

ALUM. SOFFIT CEILINGUNDER CONTRACT A -GENERAL CONTRACTOR

VENTED ALUM. SOFFITUNDER CONTRACT A -GENERAL CONTRACTOR

PTD. STL. BEAMSUNDER CONTRACTA - GENERALCONTRACTOR

CENTRAL CANOPYUNDER CONTRACT A -GENERAL CONTRACTOR

GUTTERS & DOWNSPOUTSBY CANOPY MFR. DOWN-SPOUT TO BE TIED INTOEXISTING STORM DRAIN ATGRADE BY OWNER - TYP.

C

D

E

F

1 2 3 4 5 6 7

1

A301

1

A301

2

A301

STANDING SEAM METAL ROOF -SEE DETAIL A ON A301UNDER CONTRACTA - GENERAL CONTRACTOR

SLOPE4:12

SLO

PE

4:12

SLOPE4:12

SLO

PE

4:12

LINE OF 4' WIDESTRUCTURAL INSULATEDROOF PANELS - TYP.

GUTTERS & DOWNSPOUTSBY CANOPY MFR. DOWN-SPOUT TO BE TIED INTOEXISTING STORM DRAIN ATGRADE BY OWNER - TYP.

DS DS

DS

DS

DS

DS TO MATCH CANOPYBELOW UNDER CONTRACT A -GENERAL CONTRACTOR

DS TO MATCH CANOPYBELOW UNDER CONTRACTA - GENERAL CONTRACTOR

CENTRAL CANOPYINCLUDING GUTTERS &TWO DOWNSPOUTS UNDERCONTRACTA - GENERAL CONTRACTOR

ICE GUARDS -TYP. (4)

C

D

E

F

1 2 3 4 5 6 7

11' -

0"

9' -

0"

11' -

0"

1

A301

1

A30113' -

0"

9' - 0" 11' - 0" 11' - 0" 11' - 0" 11' - 0" 11' - 0" 8' - 11 3/4"

11' -

0"

11' - 0"

1' - 0"1' - 0"

12' -

0"

2

A301

CANOPY DOWNSPOUT TOGRADE. DOWNSPOUT TO BETIED INTO EXISTING STORMDRAIN AT GRADE BY OWNER

ALL CONCRETE PATCHINGBY OWNER - TYP.

ALL CONCRETE PATCHINGBY OWNER - TYP.

CANOPY DOWNSPOUT TOGRADE. DOWNSPOUT TO BETIED INTO EXISTING STORMDRAIN AT GRADE - BY OWNER

EXISTING CONCRETESIDEWALK

A301B

EDGE OF CANOPY ABOVE - TYP.

CENTRAL CANOPYUNDER CONTRACT A -GENERALCONTRACTOR

FA

CE

OF

BU

ILD

ING

SAND, PRIME, & PAINT ALL REMAININGTUBE STEEL COLUMNS UNDER CONTRACTA - GENERAL CONTRACTOR

12' - 0"

1' - 3"

1' -

7 1

/8"

TCETIHCRA

DERETSIGE

R

STA

TEOF

WEST VIRG

INIA

PAMELA JO

WEAN

N0. 3331

DATE FILEAUG. 10, 2016

SHEET

#

BR

IDG

EP

OR

T H

IGH

SC

HO

OL

CA

NO

PY

RE

PLA

CE

ME

NT

BR

IDG

EP

OR

T, W

ES

T V

IRG

INIA

2016

MS

ES

AR

CH

ITE

CT

SC

MSES 16-1011

PLANS

A101

SCALE: 1/8" = 1'-0"DEMO PLAN

SCALE: 1/8" = 1'-0"REFLECTED CEILING PLAN

SCALE: 1/8" = 1'-0"ROOF PLAN

SCALE: 1/8" = 1'-0"FLOOR PLAN

16'8'4'0'N

CONTRACT B - BID NO. 1:

PROVIDE PRE-ENGINEERED STRUCTURAL INSULATEDROOF PANEL CANOPY SYSTEM UNDER CONTRACTB - CANOPY CONTRACTOR.

CONRTACT B - BID NO. 2:

PROVIDE PRE-ENGINEERED FLAT PAN ALUM. CANOPYSYSTEM UNDER CONTRACT B - CANOPY CONTRACTOR

ALL WORK SHOWN ON THIS PLAN TO BE PROVIDEDUNDER CONTRACT B - CANOPY CONTRACTOR, UNLESSNOTED OTHERWISE.

MULTI-PRIME CONTRACTORS:

CONTRACT A - GENERAL CONTRACTORCONTRACT B - CANOPY CONTRACTOR

ALL WORK SHOWN ON THIS PLAN TOBE PROVIDED UNDER CONTRACTB - CANOPY CONTRACTOR,UNLESS NOTED OTHERWISE.

ALL WORK SHOWN ON THIS PLAN TOBE PROVIDED UNDER CONTRACTB - CANOPY CONTRACTOR,UNLESS NOTED OTHERWISE.

• ALL ELECTRICAL DEMO AND NEW WORK BY OWNER.• ALL STORM DRAINAGE DEMO AND NEW WORK BELOW

GRADE BY OWNER• ALL CONCRETE PATCHING AT EXISTING SIDEWALK BY

OWNER

ALL WORK SHOWN ON THIS PLAN TO BE PROVIDEDUNDER CONTRACT A - GENERAL CONTRACTOR, UNLESSNOTED OTHERWISE.

REVISIONS

GENERAL INFO

Page 3: BRIDGEPORT HIGH SCHOOL CANOPY … · a101 floor plans a601 sections, ... bridgeport high school canopy replacement bridgeport, west virginia ... bridgeport high school canopy replacement

1 2

3 4 5 6 7

2

A301

1' - 6" 1' - 6"

412

SURFACE MOUNTED LIGHTFIXTURES BY OWNER

LINE OF 4' WIDESTRUCTURAL INSULATEDPANELS - (TYP.)

EXIST. COLUMN (TYP.)

CENTRAL CANOPY UNDERCONTRACT A - GENERALCONTRACTOR

F1 BEYOND

CUT & REMOVE TOPS OFCOLUMNS TO BE 8' - 0" HIGH -UNDER CONTRACT A -GENERAL CONTRACTOR. SEEDEMO PLAN FOR LOCATIONS

SAND, PRIME ANDPAINT COLUMNSUNDER CONTRACT A

10 1

/4"

8' -

0"

CANOPY PANELS, FRAMING ANDCONNECTIONS UNDER CONTRACT B -CANOPY CONTRACTOR

CONTRACT B - NO. 1: INTERNAL FAN BOX/CONDUIT UNDERCONTRACT B - CANOPY CONTRACTORCONTRACT B - NO. 2:OWNER TO PROVIDE UNISTRUT FRAMING@ LIGHT FIXTURES

WORK POINT/BOTTOM OF TS BEAM

8' - 7"±(COORDINATE TO ALIGN W/TOP OF CANOPY FRAMING)

T/ SIDEWALK0' - 0"

TOP OF COLUMN10' - 9"± V.I.F.

1

A301

A301A

412

A301D

SURFACE MOUNTED LIGHTFIXTURE - BY OWNER

FRAME

EQ. EQ. EQ. EQ.

F1 BEYOND

CENTRAL CANOPYUNDER CONTRACT A -GENERALCONTRACTOR

8' -

0"

CO

NT

RA

CT

BC

AN

OP

Y C

ON

TR

AC

TO

R

F1

TOP OF COLUMN10' - 9"± V.I.F.

WORK POINT/BOTTOM OF TS BEAM

8' - 7"±(COORDINATE TO ALIGN W/TOP OF CANOPY FRAMING)

T/ SIDEWALK0' - 0"

TYP.

C D E F

SEE TYP. NOTESON SECT. 1/A301

ALUM. FASCIA OVERPT 2X8 FASCIA BOARD

CONT. GUTTER &DOWNSPOUT TO SPILLOUT ON CANOPY BELOW

PT 2X4 TOP PLATE BOLTEDTO TS 4X8 BEAM

STANDING SEAM METAL ROOFINGOVER SLIP SHEET OVER 3/4" EXTERIORGRADE PLYWOOD SUBSTRATE

RIDGE/HIPFLASHING

TS 4X8X1/4" BEAMWELDED TO SIDEOF COLUMNS - TYP.

DOUBLE 6" FULLY VENTEDALUMINUM SOFFIT W/J TRIM @ BOTH ENDS

PAINTED H.M. FRAME.SHIM AND CAULK AS NECESSARY

412

STRUCTURAL INSUL. PANELS,BEAMS AND CONNECTIONSUNDER CONTRACT B -CANOPY CONTRACTOR

F1

DOUBLE 6" SOLIDALUM. SOFFIT

SURFACE MOUNTEDLIGHT FIXTURE BYOWNER

TOP OF COLUMN10' - 9"± V.I.F.

WORK POINT/BOTTOM OF TS BEAM

8' - 7"±(COORDINATE TO ALIGN W/TOP OF CANOPY FRAMING)

ALL WORK SHOWN ON THIS DETAIL TO BEPROVIDED UNDER CONTRACT A - GENERALCONTRACTOR, UNLESS NOTED OTHERWISE

PTD. TS 4X4X1/4"BEYOND

2X6

2X6

1' - 6"

ALUM.TRIM

ICE GUARDS - 4 SIDES

1/4" TEMP.GL.

1

1' - 0"

1' -

0"

TS 4X4X1/4" COLUMN W/8X8X3/8" BASE PLATE

EXISTING CONC.SIDEWALK

C

A301

1"CL

1/2" HILTY EPOXY ANCHORBOLTS - DRILLED INTOEXIST. CONC. 6"

EXIST. CONC. PIER SIZE ISASSUMED - VERIFY INFIELD & CONTACT ARCH. IFCONDITIONS VARY.

OWNER WILL PATCHSURROUNDING CONC.SIDEWALK

D

STRUCT. INSUL. PANELS, BEAMS &CONNECTIONS UNDER CONTRACT B -CANOPY CONTRACTOR

GUTTER SYSTEM BY CANOPY MFR.DOWNSPOUT TO BE TIED INTOEXISTING STORM DRAIN @ GRADEBY OWNER

BOX BEAM BY CANOPY MFR.

EXISTING COLUMN CUTTO 8' - 0" HIGH UNDERCONTRACT A - GENERALCONTRACTOR

WORK POINT/BOTTOM OF TS BEAM

8' - 7"±(COORDINATE TO ALIGN W/TOP OF CANOPY FRAMING

1

TS 4x4x1/4" COLUMN - WELDTO 8X8X3/8" BASE PLATE

CONCRETE PIERFOUNDATION @ ELEV. -4"±

CL

COAT ALL STEEL BELOWSLAB W/ HEAVY LAYER OFTAR EMULSION

EXIST. CONC. PIER SIZE ISASSUMED - VERIFY INFIELD & CONTACT ARCH. IFCONDITIONS VARY.

1/2"x1/4" SILICONE CAULKBY OWNER

1/2"x4" CLOSED CELLPOLYPROPYLENE W/1/4" TEAR AWAY TOP -BY OWNER

T/ SIDEWALK0' - 0"

OWNER WILL PATCHCONC. SIDEWALK

1/2" HILTY EPOXYANCHOR BOLTS -DRILLED INTO EXIST.CONC. 6"

X

V.I.F.

9' - 0" ±

2"2"

1/4" TEMP. GLASS

X

2" T

YP

.

10' -

9"±

V.I.

F.

F1 HM FRAME - TYP. 4

PRIME & PAINT

V.I.

F.

1' -

6"

TCETIHCRA

DERETSIGE

R

STA

TEOF

WEST VIRG

INIA

PAMELA JO

WEAN

N0. 3331

DATE FILEAUG. 10, 2016

SHEET

#

BR

IDG

EP

OR

T H

IGH

SC

HO

OL

CA

NO

PY

RE

PLA

CE

ME

NT

BR

IDG

EP

OR

T, W

ES

T V

IRG

INIA

2016

MS

ES

AR

CH

ITE

CT

SC

MSES 16-1011

SECTIONS & DETAILS

A301

SCALE: 1/4" = 1'-0"A301

1 SECTION

SCALE: 1/4" = 1'-0"A301

2 SECTIONSCALE: 3/4" = 1'-0"A301

A DETAIL

SCALE: 3/4" = 1'-0"A301

B POST DETAIL3D ELEVATIONSCALE: 3/4" = 1'-0"A301

D DETAIL

0' 2' 4' 8'

0' 2' 4' 8' 2'1'0'

2'1'0'SCALE: 3/4" = 1'-0"A301

C COLUMN DETAIL3D ELEVATION

SCALE: 1/4" = 1'-0"FRAME TYPE

ALL WORK SHOWN ON THIS DETAIL TO BE PROVIDEDUNDER CONTRACT B - CANOPY CONTRACTOR, UNLESSNOTED OTHERWISE

ALL WORK SHOWN ON THIS DETAIL TO BE PROVIDEDUNDER CONTRACT A - GENERAL CONTRACTOR,UNLESS NOTED OTHERWISE

ALL WORK SHOWN ON THIS DETAIL TO BE PROVIDEDUNDER CONTRACT A - GENERAL CONTRACTOR,UNLESS NOTED OTHERWISE

ALL WORK SHOWN ON THIS DETAIL TO BE PROVIDEDUNDER CONTRACT A - GENERAL CONTRACTOR,UNLESS NOTED OTHERWISE

REVISIONS

NOTE:DETAILS OF CONTRACT B CANOPY AREDRAWN AND NOTED ON THIS DRAWINGAS STRUCTURAL INSUL. PANELS (BIDNO.1) SIMILAR CONDITIONS APPLYUNDER CONTRACT B - BID NO. 2

Page 4: BRIDGEPORT HIGH SCHOOL CANOPY … · a101 floor plans a601 sections, ... bridgeport high school canopy replacement bridgeport, west virginia ... bridgeport high school canopy replacement

C1

C1

C1

C1 C1 C1 C1 C1

11111

1

1

3

3

4

4

33 3

4 44 4

2 2 2 2 2

2

2

5

C1

C1

C1

C1 C1 C1 C1 C1

2

2

3

3

22 2

3 33 3

1 1 1 1 1

1

1

4

REMOVE EXISTING LIGHT FIXTURE. EXISTINGWIRING IS ROUTED TO FIXTURE THRUCOLUMN. REMOVE WIRING BACK TO SOURCE.

REMOVE EXPOSEDJUNCTION BOXES,

CONDUIT AND WIRINGBACK TO SOURCE.

REMOVE EXISTING LIGHT FIXTURE.REMOVE ASSOCIATED BOX,CONDUIT AND WIRING BACK TOSOURCE UNLESS BEING REUSED.

REMOVE EXISTING LIGHT FIXTURE.EXISTING WIRING IS ROUTED TO

FIXTURE THRU COLUMN. REMOVEWIRING BACK TO SOURCE.

REMOVE EXISTING LIGHT FIXTURE.REMOVE ASSOCIATED WIRING

BACK TO SOURCE. PROVIDEBLANK FACEPLATE OVER BOX.

REMOVE EXISTING LIGHT FIXTURE. REMOVEASSOCIATED BOX, CONDUIT AND WIRING

BACK TO SOURCE UNLESS BEING REUSED.

REMOVE EXISTING LIGHT FIXTURE.REMOVE ASSOCIATED BOX,CONDUIT AND WIRING BACK TOSOURCE UNLESS BEING REUSED.

DATE FILEAUG. 10, 2016

SHEET

#

BR

IDG

EP

OR

T H

IGH

SC

HO

OL

CA

NO

PY

RE

PLA

CE

ME

NT

BR

IDG

EP

OR

T, W

ES

T V

IRG

INIA

*FOR

REFERENCE

ONLY*

2016

MS

ES

AR

CH

ITE

CT

SC

MSES 16-1011

ELECTRICAL PLAN

E101

ELECTRICAL GENERAL NOTES

1 ALL ELECTRICAL WORK SHALL BE IN COMPLIANCE WITH THE CURRENT EDITION OF THE NATIONAL ELECTRIC CODE ADOPTED BY THE STATE OF WEST VIRGINIA.2 ALL ELECTRICAL WORK SHALL BE PERFORMED BY ELECTRICIANS LICENSED BY THE STATE OF WEST VIRGINIA.

1/8" = 1'-0"1 LIGHTING PLAN (IF CONTRACT B - BID NO.1 IS ACCEPTED)

1/8" = 1'-0"3 LIGHTING PLAN (IF CONTRACT B - BID NO.2 IS ACCEPTED)

1/8" = 1'-0"2 ELECTRICAL DEMOLITION PLAN

LIGHT FIXTURE SCHEDULE

TYPE MANUFACTURER CATALOG DESIGNATION DESCRIPTIONLAMPS VOLTAGE WATTAGE

C1 120VLITHONIA LED 16.6W OLCFM-15-4000K-WH ROUND EXTERIOR SURFACE MOUNTED LED CANOPY FIXTURE

LIGHTING KEYNOTES (IF CONTRACT B - BID NO.1 IS ACCEPTED)

1 SECURE LIGHT FIXTURE TO FAN BEAMS. SEE SHEET A101 FOR FAN BEAM LOCATIONS. COORDINATE WITH CANOPY PROVIDER.2 ROUTE CONDUCTORS CONCEALED IN FAN BEAM RACEWAY FROM SURFACE RACEWAY OUT TO LIGHT FIXTURE. COORDINATE WITH CANOPY PROVIDER.3 PROVIDE JUNCTION BOX AT COLUMN. PROVIDE (3) #12 CONDUCTORS TO EXTEND EXISTING CIRCUIT FROM COLUMN TO NEW LIGHT FIXTURE.4 PROVIDE SURFACE METAL RACEWAY TO ROUTE CONDUCTORS FROM COLUMN TO FAN BEAM. PAINT SURFACE RACEWAY TO MATCH CANOPY SURFACE.5 EXTEND EXISTING CIRCUIT FROM NEAREST COLUMN TO LIGHT FIXTURE LOCATION. ROUTE CONDUCTORS IN 3/4" CONDUIT CONCEALED ABOVE CEILING.

#

LIGHTING KEYNOTES (IF CONTRACT B - BID NO.2 IS ACCEPTED))

1 PROVIDE UNISTRUT BETWEEN BEAMS TO MOUNT LIGHT FIXTURES. ROUTE CONDUCTORS CONCEALED IN UNISTRUT FROM SURFACE RACEWAY OUT TO LIGHTFIXTURE. PROVIDE CLOSURE STRIP ON FULL LENGTH OF UNISTRUT. PAINT TO MATCH CANOPY CEILING.

2 PROVIDE JUNCTION BOX AT COLUMN. PROVIDE (3) #12 CONDUCTORS TO EXTEND EXISTING CIRCUIT FROM COLUMN TO NEW LIGHT FIXTURE.3 PROVIDE SURFACE METAL RACEWAY TO ROUTE CONDUCTORS FROM COLUMN TO UNISTRUT. PAINT SURFACE RACEWAY TO MATCH CANOPY SURFACE.4 EXTEND EXISTING CIRCUIT FROM NEAREST COLUMN TO LIGHT FIXTURE LOCATION. ROUTE CONDUCTORS IN 3/4" CONDUIT CONCEALED ABOVE CEILING.

#

ALL ELECTRICAL WORK SHALL BE BY OWNER. THISSHEET IS FOR REFERENCE AND COORDINATIONONLY. CONTRACTORS SHALL COORDINATE ALLCANOPY WORK WITH OWNER'S ELECTRICIANS.

REVISIONS