Brief description of the INAF/IAPS facility.
The IAPS-INAF plasma chamber is designed to reproduce a large volume of plasma with ionospheric parameters, for testing payloads envisioned to operate onboard LEO spacecrafts.
A plasma beam (Ar+) is accelerated within the chamber at a speed which simulates the relative velocity of the spacecraft w.r.t. the ionosphere (≈ 8km/s).
•Plasma density: ≈ 1012 – 1013 m-3 .
•Electron temperature: ≈ 1000 – 3000 K .
•Neutral pressure ≈ 5∙10-6 mbar (with plasma source in operation).
•Magnetic field: 0 – 1∙10-4 T (directions parallel and orthogonal w.r.t. plasma beam).
•Plasma diagnostics based on Langmuir Probes and Ion Drift Meters).
INAF PLASMA CHAMBER FACILITY
4.5 m
WP Manager and Test conductor Giuliano Vannaroni Associato INAF-IAPS, Uninettuno
Test conductor Piero Diego Associato INAF-IAPS, Università di Trento
Responsible of Facility Elisabetta De Angelis INAF-IAPS
Mechanical h/w design Alfredo Morbidini INAF-IAPS
1.7 m
Refurbishment of Plasma Chamber Facility - 1 (June 2014 – 23 January 2015) completed
• Maintenance of vacuum system: service on Cryo-pump, Screw-line, Roots, Valves, etc. .
• Tests on plasma: gas flow control, plasma source, magnetic coils, s/w plasma diagnostics, etc. .
Cryo/Chamber Valve He gas - Compressor Plasma Source Power Supplies
1.76 1.76 13 turns 13 turns 10 turns
16 turns
16 turns
3. 3 4
4.48
z
y
Refurbishment of Plasma Chamber Facility - 2 (June 2014 – 23 January 2015) completed
3
0y
0yyy 103.5
B
BB//AH
4
0y
yy 101.3
B
BOF
3
0z
0zzz 105.5
B
BB//AH
3
0z
zz 106.1
B
BOF
G/A)( 0621.0I
BS
y
y0y
G/A)( 0436.0I
BS
z
z0z
View of Plasma Chamber FacilityMagnetic field coil system
Axial Homogeneity @ 1m3 Orthogonal Factor @ 1m3 Coil Sensitivity Maximum field
yB 1 G
zB 1 G
Refurbishment of Plasma Chamber Facility - 3 (June 2014 – 23 January 2015) completed
Test of s/w for real time analysis of plasma diagnostics, and data acquisition