building automation news | 05'2016 · building automation news ... the engineering software...

8
Building Automation News | 04 2016

Upload: lamnhu

Post on 25-Jul-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Building Automation News | 05'2016 · Building Automation News ... The engineering software essentially ... Easy Engineering with TwinCAT Building Automation Import

Building Automation News | 04 2016Building Automation News | Building Automation News | 04 201604 2016

Page 2: Building Automation News | 05'2016 · Building Automation News ... The engineering software essentially ... Easy Engineering with TwinCAT Building Automation Import

Rendering KlemmenRendering KlemmenRendering KlemmenRendering KlemmenIndividually Confi gured and Easily Installed: the eXtendable Room Box.

Five steps to a solution1. The client develops the design of the building together with the architect. 2. The engineering is done quickly by the technical planner using TwinCAT BA. The system integrator can conveniently use the data in the work planning. 3. Automated confi guration of the eXtendable Room Box takes place via the TwinCAT BA Box Confi gurator for the planner or system integrator. 4. The box is produced by Beckhoff or an external partner. It is also possible to create a parts list for in-house assembly.5. Finally, a simple installation of the eXtendable Room Box (fully prefabricated box with installation drawing/circuit diagram) is possible, optionally with terminal blocks or pluggable wires.

Modular, extendable and easily confi gured in the project planning phase using the Box Confi gurator in TwinCAT Building Automation: The eXtendable Room Box (XRB) covers all hardware functions and allows every degree of freedom with regards to protection class, material and setup. The prefabricated plug-and-play solution is completely preassembled and is optionally available with pluggable or conventional wiring. Fast engi-neering of PLC and hardware, industrial prefabrication, simple and fail-safe installation, saving of technical space and maximum extendability go all the way to make the eXtendable Room Box a solution that provides security for your investments.

The eXtendable Room Box includes the freely selectable mounting box and the necessary Bus Terminal I/O. The user obtains, virtually by mouse-click, a fully confi gured box that can be wired in the building via plug-and-play. For technical planners and system integrators, this ensures minimal engineering costs coupled with the greatest possible freedom in design: maximum customisation of the completely prefabricated boxes is possible down to a quantity of one.

2

Product announcement For availability status of the new products see Beckhoff website at: www.beckhoff.com

Page 3: Building Automation News | 05'2016 · Building Automation News ... The engineering software essentially ... Easy Engineering with TwinCAT Building Automation Import

Easy engineering for smart buildings

The eXtendable Room Box is fl exible from the outset and grants the planner every freedom: enclosure, protection class and material are freely selectable, depending on the place of use. In addition, an adjustable space reserve is provided for future extensions. The solution also proves to be “smart” when it comes to installation: whether it is manufactured directly by Beckhoff or by one of Beckhoff‘s partner companies, the box is delivered fully pre-wired with the installation drawing and circuit diagram as an industrially and individually prefabricated plug-and-play solution, optionally with pluggable or classic wiring. This means no technical per-sonnel are required for the installation.

Depending on the design, the box can be placed anywhere – on the ceiling or the wall, in the fl oor, indoors and outdoors, and even in a fl ush-mounted version. The eXtendable Room Box is also fl exible in practice. The front end interface can be solved conveniently with the aid of smart-phones. Control panels in the rooms can be connected wirelessly or even omitted altogether, if preferred, to maintain a particular room aesthetic.

www.beckhoff.com/XRB

Individually Confi gured and Easily Installed: the eXtendable Room Box.

Easy engineering for smart buildings

The eXtendable Room Box is fl exible from the outset and grants the planner every freedom: enclosure, protection class and material are freely selectable, depending on the place of use. In addition, an adjustable space reserve is provided for future extensions. The solution also proves to be “smart” when it comes to installation: whether it is manufactured directly by Beckhoff or by one of Beckhoff‘s partner companies, the box is delivered fully pre-wired with the installation drawing and circuit diagram as an industrially and individually prefabricated plug-and-play solution, optionally with pluggable or classic wiring. This means no technical per-sonnel are required for the installation.

Depending on the design, the box can be placed anywhere – on the ceiling or the wall, in the fl oor, indoors and outdoors, and even in a fl ush-mounted version. The eXtendable Room Box is also fl exible in practice. The front end interface can be solved conveniently with the aid of smart-phones. Control panels in the rooms can be connected wirelessly or even omitted altogether, if preferred, to maintain a particular room aesthetic.

www.beckhoff.com/XRB

Individually Confi gured and Easily Installed: the eXtendable Room Box.

Freely selectable mounting box for

installation in walls, ceilings or fl oors,

indoors or outdoors

Easy installation with pluggable

or classic wiring

Embedded PC or any Bus Coupler as

the “brains” of the I/O station

Choice of about 400 Bus Terminals

New Automation TechnologyBECKHOFF

3

We reserve the right to make technical changes.

Page 4: Building Automation News | 05'2016 · Building Automation News ... The engineering software essentially ... Easy Engineering with TwinCAT Building Automation Import

TwinCAT Building Automation –

effi cient engineering for all building systems

TwinCAT Building Automation integrates all essential functions for every system and reduces engineering time. Extensive software libraries and supplements continue the concept of the modular Beckhoff automa-tion toolkit at the software level. The engineering software essentially encompasses the following functions:

TwinCAT BA PLC Libraries: basic functions for all building systems

TwinCAT BA PLC Templates: function templates for all building systems

TwinCAT BA Project Builder: confi guration tool that links templates, hardware and BACnet objects with one another, as well as with the new TwinCAT BA Box Confi gurator

NEW: TwinCAT BA Box Confi gurator

TwinCAT BA PLC Libraries

The TwinCAT BA PLC libraries provide the system integrator with esta-blished and tested functions. These include basic functions from the fi elds of control, signal processing, special mathematical functions, error message processing and general system functions.

TwinCAT BA PLC Templates

The TwinCAT BA PLC templates consist of ready-to-use TwinCAT program blocks for sensors and actuators, for complete modules and system parts or complete systems for heating, ventilation, air condi-tioning and room automation. As opposed to a regular PLC library, TwinCAT BA PLC templates are imported as program blocks into the PLC programs. The system integrator can carry out any necessary adap-tations independently. Moreover, users have the ability to create their own TwinCAT BA PLC templates.

TwinCAT BA Project Builder

The universal structure of the TwinCAT project fi les is the basis for an easily maintainable system. The central concept here is the system iden-tifi cation system (SIS), which assigns a name to each data point, each BACnet object and each program block according to fi xed rules. The TwinCAT BA Project Builder automatically generates the project fi les for the TwinCAT PLC Control and the TwinCAT System Manager for all Beckhoff controllers.

Easy Engineering with TwinCAT Building Automation

4

Product announcement For availability status of the new products see Beckhoff website at: www.beckhoff.com

Page 5: Building Automation News | 05'2016 · Building Automation News ... The engineering software essentially ... Easy Engineering with TwinCAT Building Automation Import

TwinCAT BA Box Confi gurator Based on an open Excel list that each user can access, the technical planner can precisely determine the costs even during pre-planning. The hardware modules can be selected as function modules and the matching tendering text and parts lists are then automatically created from these. Regardless of whether the project has numerous different boxes or whether they are all the same, the project can be modularised during pre-planning by means of freely created XRB typologies. It is thus ready for industrial prefabrication. With the TwinCAT BA Box Confi gurator, information is never lost. The complete planning data can be adopted from the planning phase to the implementation phase, sup-plemented by details and forwarded to production.

www.beckhoff.com/TS8040Power supply

SMI bus

DALI bus

EnOcean gateway

Ceiling box

Wall box

Floor box

°C

kWhkWh

TT

Easy Engineering with TwinCAT Building Automation

Import

Planning data

Project

implementation

EngineeringEngineering

TwinCAT BA Box Confi gurator

EN15232,VDI3814, VDI3813,XLS …

Confi gurator

TwinCAT BA PLCLibraries

TwinCATBA PLCTemplates

TwinCAT BA ProjectBuilder

Project

TwinCAT PLC,System Manager

New Automation TechnologyBECKHOFF

5

We reserve the right to make technical changes.

Page 6: Building Automation News | 05'2016 · Building Automation News ... The engineering software essentially ... Easy Engineering with TwinCAT Building Automation Import

BACnet/IP controllers support latest features of revision 12

TwinCAT IoT & BACnet/IP

TwinCAT IoT: the fast, stan- dardised route into the cloud

With the new TwinCAT IoT, the TwinCAT 3 engineering and automation software provides a complete solution for fast and effi cient realisation of IoT and Industrie 4.0 concepts. TwinCAT IoT supports standardised protocols for cloud communication and for sending push notifi cations to smart devices. TwinCAT 3 IoT is fast and easy to confi gure. Together with an Embedded PC or Industrial PC used as IoT controller, the software provides a seamless connec-tion between the Internet of Things and the Internet of Services.

www.beckhoff.com/TwinCAT-IoT

With a large range of BACnet controllers, Beckhoff provides solutions that are precisely scalable in terms of performance for all applications. Particularly suitable are the CX90xx and CX50xx Embedded PC series which directly integrate the modular I/O level. The implementation of BACnet revision 12 in TwinCAT, enabling extended services and additional object types, has increased the execution performance and offers numerous advantages for building automation.

www.beckhoff.com/BACnet

With a large range of BACnet controllers, Beckhoff provides solutions that are precisely scalable in terms of performance for all applications. Particularly suitable are the CX90xx and CX50xx Embedded PC series which directly integrate the modular I/O level. The implementation of BACnet revision 12 in TwinCAT, enabling extended services and additional object types, has increased the execution performance and offers numerous advantages for

www.beckhoff.com/BACnet

6

Product announcement For availability status of the new products see Beckhoff website at: www.beckhoff.com

Page 7: Building Automation News | 05'2016 · Building Automation News ... The engineering software essentially ... Easy Engineering with TwinCAT Building Automation Import

Transparent energy data management enables cost optimisation

Lighting & Energy

DALI 2: Beckhoff supports new standard for lighting technology

Edition 2 of the DALI standard extends the range of functions for lighting technology, e.g. for event-controlled communi-cation. With the new KL6821 multi-master terminal, each Beckhoff controller becomes a DALI 2 master. DALI 2 bus circuitry and power supply are integrated within the standard terminal, which is just 12 mm wide. TwinCAT function blocks simplify engineering, for example through a fl exible adaptation of the building utilisation by providing software support for the division of the building into room zones with the aid of sensors or light operating devices.

www.beckhoff.com/KL6821

Intelligent energy management makes a signifi cant contribution to optimise effi ciency in buildings, properties or plants. With PC-based control, Beckhoff provides an integrated platform for a transparent recording and processing of all energy consumption data. The consumption data is recorded by Beckhoff I/O components and provided to higher-level energy management or cloud-

based systems. TwinCAT software enables the pre-processing of measured data via analysis, database logging or visualisation functions.

www.beckhoff.com/energy-data-management

DALI 2: Beckhoff supports new standard for lighting technology

Edition 2 of the DALI standard extends the range of functions

circuitry and power supply are integrated within the standard terminal, which is just 12 mm wide. TwinCAT function blocks simplify engineering, for example through a fl exible adaptation of the building utilisation by providing software support for the division of the building into room zones with the aid of sensors

New Automation TechnologyBECKHOFF

7

We reserve the right to make technical changes.

Page 8: Building Automation News | 05'2016 · Building Automation News ... The engineering software essentially ... Easy Engineering with TwinCAT Building Automation Import

DK1

322-

0316

Beckhoff®, TwinCAT®, EtherCAT®, EtherCAT P®, Safety over EtherCAT®, TwinSAFE®, XFC® and XTS® are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners.

© Beckhoff Automation GmbH & Co. KG 03/2016

The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual application do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressively agreed in the terms of contract.

HeadquartersBeckhoff Automation GmbH & Co. KGHuelshorstweg 2033415 VerlGermanyPhone: + 49 5246 [email protected]

www.beckhoff.com/building