building services new commercial submittal package packet.pdf · in accordance with chapter 18 of...
TRANSCRIPT
Building Services
New Commercial Submittal Package
Introduction
The City of Meridian requires a new commercial submittal package for new
construction, additions to an existing structure, and for façade or exterior
improvement. This handout is intended to help facilitate a smooth, no
surprises experience for our customers. The New Commercial submittal package includes a checklist and several
forms which are required for a complete application. It is required that all
sections of the checklist be addressed. This includes submissions to the
Meridian Planning Division and Ada County Highway District (ACHD). Failure
to provide all required and completed materials will result in delays.
» All plan submittals must be signed, dated, and stamped by the
responsible licensed professional.
» A Certificate of Zoning Compliance (CZC) must be completed with
the Meridian Planning Division prior to New Commercial Application
submittal. You may also want to discuss signage for your project at
this time.
» Applicants may walk-in and submit “over the counter” at any time.
In addition to the forms included within a New Commercial Application
package, approval and written documentation may be required from Central
District Health Department (CDHD) as part of the submittal requirements.
» If your project includes food storage, handling or manufacturing,
CDHD approval and stamp is required on submitted plan sets.
Next Steps
When your plans have been approved, Meridian Building Services will send an
e-mail notification that the plans are ready for download. After official final
inspections are completed for new commercial improvements, a Certificate
of Occupancy (CO) will be issued by the City. A CO is required prior to use
or occupancy of any new commercial space.
If you have questions or would like to schedule a pre-submittal meeting to
discuss the specifics of your project, please call (208) 887-2211
What is a CO?
» A CO is a Certificate of Occupancy and is
required for every business prior to use or
occupancy of any structure. This includes
name changes, ownership changes, and any
alteration involving construction.
Contact Info!
Meridian Building Services
» The First floor of City Hall at 33 E. Broadway
Ave. Suite 102, Meridian, Idaho 83642 » Building | 208.887.2211
» Planning | 208.884.5533
Online Citizen Access Portal citizenportal.meridiancity.org/citizenaccess/
» The Citizen Access Portal is an electronic service
offered to our citizens, businesses, and visitors 24 hours a day, 7 days a week.
» With a free user account, you will be able to:
view permit information, track plan review comments and permit status, download approved construction documents, retrieve certificate of occupancy, pay fees, and schedule inspections online.
Online Citizen Access User Guide
https://goo.gl/CXDFiV
» Need help with the Citizen Access Portal?
Utilize the Citizen Access User Guide. This guide is intended to help explain the various aspects of permit review through Citizen Access. For questions, contact the Buildings Services Division.
» Community Development: 33 E Broadway Ave, Suite 102, Meridian ID 83642
Rev. 7/2018
New Commercial –Submittal Package
» Community Development: 33 E Broadway Ave, Suite 102, Meridian ID 83642 Rev. 7/2018
Critical to a smooth and efficient application process is the need for all required materials to be completed and included
with the application. For additional information on each of these steps, see the New Commercial Application Submittal
package.
» Pickup or download a New Commercial Submittal Package
» Consult with Meridian Planning Division and complete Certificate of Zoning Compliance (CZC)
» Submit Address Verification Request to [email protected]
» Complete the Submittal Requirement’s (For submittal standards utilize this link:) https://goo.gl/CXDFiV
1. Consult with; and if necessary acquire CDHD stamp of approval on submittal plans
2. Completed Commercial Application-New Commercial
3. Completed Address Verification Form
4. Completed Plumbing Summary
5. Completed Certificate of Value
6. Meet Meridian Wastewater Industrial Pretreatment requirements
7. Meet Meridian Floodplain Requirements
8. Completed ComCheck-Envelope, Electrical, and Mechanical Compliance (see adopted codes)
9. Completed Structural Calculations and Specifications
10. Completed – Drainage Calculations, stamped and signed by licensed professional
11. Completed – Street light lay-out Plans, stamped and signed by licensed civil engineer
12. One complete plan set, which includes all files in PDF format (CDHD stamped plans, Civil Sets, etc)
Each sheet / page of the drawing shall be submitted as a separate file. https://goo.gl/CXDFiV
13. Include, two (2) full size hardcopy Civil Plan sets, bundled separately, signed, and dated
Or two (2) full size hardcopy Site Plan sets, (if utility infrastructure exists), signed, and dated
» Submit completed requirements package
» Pay non-refundable $150.00 application fee. $50.00 fee if total project value is under $20,000.
» Time frames to permit issuance vary based on the workload in the system. Please contact
Meridian Building Services for estimated time frames.
Su
bm
itta
l R
eq
uir
em
en
ts
Application Process
Meridian Building Services
New Commercial Application Checklist – Page 1
Rev: 7/2018
Project name: Permit #:
Applicant/agent:
The following steps should be completed:
Applicant
() Description
Staff
()
Meridian Planning Division
Certificate of Zoning Compliance must be approved prior to Building Services submittal and plan review. Provide the
Certificate of Zoning Compliance number on the application.
Ada County Highway District You are required to submit your plans separately to ACHD. The impact fee certificate or the impact fee assessment will
be emailed from ACHD directly to Building Services. This is required before the building permit will be issued. ACHD
(208) 387-6100.
Address Verification Request Address verification is mandatory, even if your address is known and existing. Please complete and email the Address
Verification Request included in this packet to: [email protected] to receive your required
Address Verification.
Meridian Wastewater Pretreatment Requirements (208) 888-2191 Meridian Pretreatment Program reviews the wastewater discharged to sewer in construction projects for pollutants
of concern as mandated by the EPA and the City of Meridian. Specific equipment is required in the plumbing
system to control these pollutants such as grease, flammable liquids and toxic chemicals. Pretreatment Building Standards are located on the Pretreatment Program’s Website (https://goo.gl/BZdz0H) and Title 9, Chapter 2,
SEWER PRETREATMENT Meridian City Code.
Meridian City Clerk’s Office If your project involves the sale or service of alcohol, please contact the City Clerk’s Office.
(208) 888-4433
Central District Health Department If your project involves the storage, handling or manufacturing of food products, your plans must be reviewed and
“stamped approved” by the Central District Health Department prior to submittal to Building Services.
(208) 327-7499
Floodplain
If the project is located in a floodplain, a $25.00 public works fee and a completed Floodplain Development
Application are required. This document is available at the Meridian Public Works Environmental Division office or on the Public Works Department website:meridiancity.org/floodplain.
All application submittals to Meridian Building Services are required to contain the following:
Applicant
() Description
Staff
()
Application Checklist
Commercial Application – New Commercial or Shell
Address Verification Please submit the verified address document you received from Meridian Building Services.
Plumbing Summary
Certificate of Value
New Commercial Application Checklist – Page 2
Rev: 7/2018
Applicant
() Description
Staff
()
Structural Calculations and Specifications
Electronic copies of the stamped, signed and dated structural calculations and project specifications are required in
PDF Format.
Mechanical, Electrical and Plumbing Design
Full Mechanical, Electrical and Plumbing designs are required. All sheets shall be stamped and signed by an
Idaho licensed professional. Electrical Designs: The maximum available fault current at each electrical panel and equipment, to include
transformers, generators, and transfer switches if present, shall be calculated and provided on the one-line
diagram. The AIC rating of each electrical panel and equipment shall be provided on the one-line diagram or panel schedule.
Energy Compliance - Mechanical, Electrical and Envelope Compliance The most current version of Com Check is required on a full size plan sheet and on the project CD-ROM. Separate copies will not be accepted. www.energycodes.gov
Plans – One complete plan set in PDF Format (Each sheet / page of the drawing shall be submitted as a
separate file) See the Citizen Access User Guide submittal standards: https://goo.gl/CXDFiV The cover sheet shall contain all of the current adopted building codes in the City of Meridian and a complete building
code analysis. An exiting travel distance analysis and an existing plan are required. A Geotechnical soils investigation in accordance with chapter 18 of the IBC is required. Building Services will verify that all files are stamped, signed and
dated.. This includes all specifications, calculation, CDHD stamped drawings, etc.
Civil Drawings – New Main and/or Services (proposed or extended) Submit two separate hardcopies and one complete sealed, signed and dated set in PDF format. Each sheet must be sealed, signed and dated by a professional civil engineer or must be labeled according to Idaho Statues). Plans
must be submitted on sheet sizes of 22’ x 34’ or 24’ x 36’ only.
Note – Local ordinance states the fire riser room must be one hour protected with an exterior door and landing.
The F.D.C. shall be a maximum of 100 feet from a fire hydrant.
Note – For new construction or additions to existing facilities: Determine the fire flow according to the current
International Fire Code, Appendix B – Table B105.1. Use the City of Meridian link
http://apps.meridiancity.org/FireFlowRequest/ to obtain the available fire flow for the project. If the fire flow is not available there are remedies such as the use of fire sprinklers; change of construction type or the use of fire
walls. (IFC Appendix B) IFC Appendix B
Civil Drawings must also contain all City of Meridian general notes for roadway, water, sewer and pressure
irrigation and in addition, standard details if applicable. These notes are available on our website
http://meridiancity.org/city_departments/community_development_department_/land_development
OR;
Site Plans – Previously Constructed Utility Infrastructure
Submit two separate hardcopies and one complete set in PDF format (Each sheet / page of the drawing shall be submitted as a separate file) . Site plans shall show utility points of connection and location for the building and
submitted on two single page site plans. Plans must be submitted on sheet sizes of 22’ x 34’ or 24’ x 36’ only.
Warranty Surety Requirements
Record Drawings and a Warranty Surety are required to be submitted for the public works infrastructure elements of this project (i.e. sanitary sewer, water, and recycled water). The surety amount is equal to 20% of the cost of
said improvements for a period of two (2) years after the final acceptance letter has been issued from Public
Works for this project. The Surety Application and Surety Checklist can be found on the City of Meridian
website under Business/Planning/Current Planning/Application & Checklists or by calling 208-887-2211.
Drainage Calculations
Shall be stamped and signed by a licensed architect or civil engineer. One set shall be submitted and one complete
stamped, signed and dated set in PDF format.
Street Light Lay-Out Plans
Shall be stamped and signed by a licensed civil engineer and submitted in PDF Format. For additional questions
or spacing requirements of the Meridian Improvement Standards, please contact Meridian Public Works Engineering staff at (208) 898-5500.
APPLICATION WILL NOT BE ACCEPTED UNLESS ALL ITEMS ON THE CHECKLIST ARE SUBMITTED.
Meridian Building Services
Address Verification Request
Ph: 208.887.2211 www.meridiancity.org https://citizenportal.meridiancity.org/citizenaccess/ Rev: 7/2018
Requestor
Name _______________________________________________________ Phone _________________________
Address _____________________________________________________ Fax ____________________________
Email _______________________________________________________________________________________
Please check the appropriate box below and submit the required information to
[email protected]. Please allow 24 hours for reply.
Commercial Project
Required Information:
Project Name _________________________________________________________________________________
Address (if known) ____________________________________________________________________________
Lot _______ Block _______ Subdivision_________________________________________________________
Site Plan - Include adjacent street name(s)
Detailed Floor Plan to include:
Entrances – Designate “main entrance” if occupying more than one space
Proposed number of tenants and spaces – Define clearly on plan
Tenant Improvements and CO Fast Track Projects
Required Information:
Project Name _________________________________________________________________________________
Address (including suite number) _________________________________________________________________
Lot _______ Block _______ Subdivision_________________________________________________________
Detailed Floor Plan to include:
Entrances – Designate “main entrance” if occupying more than one space
Proposed number of tenants and spaces – Define clearly on plan
Sign Permit Application
Required Information:
Project Name __________________________________________________Building Permit # ________________
Address (including suite number) _________________________________________________________________
Lot _______ Block _______ Subdivision_________________________________________________________
Meridian Building Services
New Commercial Application
Office Use Only
Permit Number Assigned ________________________________
Application Fee: $150 non-refundable or $50.00-if the project value is less than $20,000
New Commercial Shell Only Addition Pool Misc.
Description of Work Being Performed ______________________________________________________________________
Professional Contractor
Name___________________________________________________ Reg. # ________________ Expiration ____________ Address _________________________________________City _________________State ______Zip Code ____________ Office Phone: __________________________ Cell______________ Email _______________________________________
Property Owner
Name _____________________________________________________________________________________________ Address _____________________________________ City ________________________ State _________ Zip _________ Office Phone ___________________________ Cell ______________Email ______________________________________
Project Information Project Name ________________________________________________________________________________________ Project Address ______________________________________________________________________________________ Lot ____ Block ____ Subdivision ____________________________________________
Code Design Data
Total Square Feet _________ Use Classification _________ Type of Construction ________ Occupant Load ________ Proposed Use____________________ Landscape Square Footage _________________
Is this property in a flood zone? Yes No (if yes, a separate flood application is required)
Retail – Will Alcohol be sold? Yes No Will Alcohol be served? Yes No
Are automatic sprinklers present? Yes No Are automatic sprinklers required for this use? Yes No
Certificate of Zoning Compliance Number _____________________________________
Registered Design Professional in Responsible Charge - (IBC section 107) Name (printed) _______________________________________________________________________________________ Business Name _______________________________________________________________________________________ Address ____________________________________________________ City ________ State _______ Zip Code _______ Phone___________________________ Email (print clearly) ___________________________________________________
Ph: 208.887.2211 www.meridiancity.org https://citizenportal.meridiancity.org/citizenaccess/ Rev: 7/2018
Under penalty of intentional misrepresentation and/or perjury, I declare that I have examined and/or made this application, and it is true and correct. I agree to construct said improvement in compliance with all provisions of the City of Meridian adopted codes and ordinances. I realize the information that I have stated hereon, and the plans and construction documentation submitted to the City of Meridian, may be incomplete, and that 100% design and drawings have not been submitted. I understand that any field inspection discrepancy, correction or change that may arise (or be required) due to lack of design is the sole responsibility of the owner, owner’s representative, design professional and contractor. My submittal forms the basis for the issuance of the building permit herein applied for, and approval of any plans in connection therewith shall not be construed to permit any construction upon said premises or use thereof in violation of any provision of the City of Meridian adopted code or any other ordinance, or to excuse the owner or his/her successors from complying therewith. I understand that no structure shall be used or occupied, until the Building Official for the City of Meridian has issued a Certificate of Occupancy, and that doing so is unlawful. WHERE NO WORK HAS BEEN STARTED AND/OR INSPECTED WITHIN 180 DAYS AFTER THE ISSUANCE OF A BUILDING PERMIT OR WHEN MORE THAN 180 DAYS LAPSES BETWEEN APPROVAL OF REQUIRED INSPECTIONS, SUCH PERMIT SHALL BE VOID. I understand that one permit extension may be granted, however an application must be made in writing, to the Building Official, prior to permit expiration. I hereby certify that I am the permit applicant for purposes of obtaining this approval and that I am acting in behalf of the owner. All contract work on this project will be done by a contractor holding valid licensing as required by the State of Idaho. I understand the application fee is a non-refundable portion of the plan review fees and will not be refunded if the project is cancelled, withdrawn or expired for any reason. Otherwise, the deposit will be credited towards the total building permit fee.
Will deferred submittals or any portion(s) of the design to be submitted after this application? Yes No ____________________________________________________________________________________________________ ____________________________________________________________________________________________________
Statement of Special Inspections Will special inspections be used on this project? Yes No If yes, all special inspection reports shall be made available to the inspector in the field prior to final inspection approval.
Design Professional Signature ___________________________________________________ Date ___________________
Applicant (printed name) _______________________________________________________________________________________ Applicant (signature) ______________________________________________________________ Date _______________________ Address_____________________________________________________________________________________________________
City ________________________________State _____ Zip________ Office Phone _________________ Cell ___________________ Email (please print clearly) ______________________________________________________________________________________
Ph: 208.887.2211 www.meridiancity.org https://citizenportal.meridiancity.org/citizenaccess/ Rev: 7/2018
Meridian Building Services
Plumbing Summary
Ph: 208.887.2211 www.meridiancity.org https://citizenportal.meridiancity.org/citizenaccess/ Rev: 7/2018
This plumbing summary should include all new plumbing fixtures being planned for the project. If any
fixtures are to be demolished or removed, please make note of this in the space provided.
Please indicate total count of new fixtures listed below:
_____ Water closets (toilets)
_____ Urinals
_____ Lavatories (bathroom sinks)
_____ Bar Sinks
_____ Clinic Sinks
_____ Floor Sinks
_____ Kitchen Sinks (single faucet)
_____ Kitchen Sinks (dual faucets)
_____ Laundry Sinks
_____ Mop Sinks
_____ Washup/Handwash Sinks
_____ Dishwashers
_____ Clothes Washers
_____ Bathtubs or Tub/Shower Combos
_____ Showers
_____ Drinking Fountains (each hi-lo fountain counts as 1)
_____ Floor drains
_____ Hose Bibs
If plumbing fixtures to be demolished or removed. Please explain.
____________________________________________________________________________________________________
____________________________________________________________________________________________________
Meridian Building Services
Certificate of Value – Page 1
Ph: 208.887.2211 www.meridiancity.org https://citizenportal.meridiancity.org/citizenaccess/ Rev: 7/2018
Applicant _________________________________________________________________________________
Project Address ____________________________________________________________________________
Tenant ___________________________________________________________________________________
Total Project Value Value $ _________________________
This is the total value of all construction work (including overhead and profit). This includes but not limited to
finish work, paint, roofing, electrical, plumbing, heating, medical gas, process piping, gas piping, generator,
elevators, air conditioning, fire suppression and indication systems as well as permanent systems and
equipment. Show each component breakdown below and include above.
Does this value include labor, materials and/or equipment supplied by others? Yes__ No__
If no, additional permits will be required for this work. Please specify _________________________________ ________________________________________________________________________________________________________________________
Electrical Value $ ________________________
Total value of all electrical work performed on the job including overhead and profit.
Does this value include labor, materials and/or equipment supplied by others? Yes__ No__
If no, additional permits will be required for this work. Please specify _________________________________ ________________________________________________________________________________________________________________________
Plumbing Value $ ________________________
Total value of all plumbing work performed on the job including overhead and profit.
Does this value include labor, materials and/or equipment supplied by others? Yes__ No__
If no, additional permits will be required for this work. Please specify _________________________________ __________________________________________________________________________________________________
Mechanical Value $ ________________________
Total value of all mechanical work performed on the job including overhead and profit.
Does this value include labor, materials and/or equipment supplied by others? Yes__ No__
If no, additional permits will be required for this work. Please specify _________________________________ ____________________________________________________________________________________________________________
Fire Sprinkler Value $ ________________________
The project value shall be the total fair market value. This shall include all labor, materials and equipment, as well as all labor, materials
and equipment supplied by others. The project value cannot be reduced by labor, material or equipment that is donated. The values
below will be verified and adjusted if required by the Meridian Building Official utilizing the most current publication of the building
valuation data published by the International Code Council.
The Total Project Value below is used to establish the Building Permit fee only. The Electrical, Plumbing, Mechanical, Fire Sprinkler,
and Fire Alarm values are included in the Total Project Value. In addition to the building permit, subcontractors will be required to
apply for each respective permit individually and pay a separate fee based upon the scope of work submitted for that particular
discipline.
Certificate of Value – Page 2
Ph: 208.887.2211 www.meridiancity.org https://citizenportal.meridiancity.org/citizenaccess/ Rev: 7/2018
Total value of all sprinkler work performed on the job including overhead and profit.
Does this value include labor, materials and/or equipment supplied by others? Yes__ No__
If no, additional permits will be required for this work. Please specify ________________________________ __________________________________________________________________________________________________
Fire Alarm Value $ _______________________
Total value of all fire alarm work performed on the job including overhead and profit.
Does this value include labor, materials, equipment supplied by others? Yes__ No___
If no, additional permits are required for this work.
***********************************************************************
I hereby attest the information herein is true and correct. I have also selected one of the two required
options below for this project.
1. All of the values provided are estimates only. The project has not been bid and awarded.
_____ TRUE (If true you will be required to submit a new certificate of value after the project is bid and
awarded and before building, mechanical, electrical, plumbing and fire permits are issued). Provide the actual
bid date _______________________.
2. All of the values herein are accurate. This project has been bid. Bid documents and/or proposals have been
received. _____ TRUE
_____________________________________________________________________________
Signature Printed Name Date
__________________________________________________________________________________________
Email Phone Company/Firm Fax
Building Services Meridian City Hall, Suite 102
33 E. Broadway Avenue
Meridian, Idaho 83642
_________________________________________________________________________
Ph: 208.887.2211 www.meridiancity.org Fax 208.887.1297 Rev: 8/14/2018
Community Development
Department
Commercial Pre-screen Checklist
Commercial Plan Naming Conventions
Discipline Sheet ID Sheet # Example File Names
Cover Sheet A0.0 1 A0.0_Cover Sheet
Index Sheet A0.1 1 A0.0_Index Sheet
Landscape L 1.1 L1.1_Overall Site
Erosion and Sediment ESC 1 ESC1_ESC Plan
Architectural A 2 A2.0_First Level Floor Plan
Structural S 1.4 S1.4_Third Level Floor Plan
Plumbing P 1.0 P1.0_Fixture Plan
Electrical E 1.0 E1.0_Lighting
Mechanical M 1.1 M1.1_First Floor Demolition
Civil C 1.0 C1.0_Topographic Site Plan
Site Plan SP 100 SP100_Site Plan
Interior Design ID 1 ID1_First Floor Finishes
Life Safety and Master Egress
LSP 1 LSP1_Master Egress
Submittal standards: Drawing file names must include the first characters of the discipline name,
followed by the sheet number and name. Electronic plans that do not meet these requirements
will fail the Prescreen review.
"Sheet ID Name: The first character must represent the discipline area (“A” for Architectural, “S”
for Structural, etc.); use more characters if required. Ensure all plans, including the associated
details, are submitted under the correct discipline.
Sheet Number: The sheet number may be listed with decimals or in whole numbers.
Building Services Meridian City Hall, Suite 102
33 E. Broadway Avenue
Meridian, Idaho 83642
_________________________________________________________________________
Ph: 208.887.2211 www.meridiancity.org Fax 208.887.1297 Rev: 8/14/2018
Community Development
Department
Sheet Name: The sheet name must clearly indicate the information found on the page. Example:
A002.1 – Second Level Floor Plan Details.
All plans must be drawn to scale and each sheet should state the scale. When more than one
scale is used on a sheet, an independent graphic scale must accompany the applicable detail.
All file names on re-submitted documents for both drawings and documents shall remain
exactly the same as the original.
Plans must be submitted as individual sheets. However, the individual PDF files may be bundled
into a single zip file to expedite the uploading process.
All plans must be submitted in Landscape format in the horizontal position.
Plans must be submitted in a PDF format. Files must be print ready, i.e. setup properly for
printing with title block, no data outside the print page area, etc.
Calculations, reports and other supporting documents (non-drawing files) must be submitted as
searchable PDF files or legible scanned documents.
Each plan must have a space reserved in the upper left corner for City approval stamps.
Architectural stamped and signed by an Idaho licensed architect; Civil, structural, mechanical &
plumbing stamped and signed by Idaho licensed engineers.
Structural calculations stamped and signed by an Idaho licensed engineer.
Code Analysis/Building Data on front sheet of plans which includes: Code year, occupancy
group(s), construction type(s), floor areas for all floors & building total floor area, building
height, fire suppression system (specify NFPA code applicable).
Soils and geotech report for support of the structure stamped and signed by an Idaho licensed
engineer.
Mechanical, Electrical, and Plumbing sheets shall be provided individually. Please do not