BuildingEnvelope®
FG-5750T STORMMAX
®
HURRICANE RESISTANT THERMALLY BROKEN STOREFRONT
2-1/2" X 5" w/ 1-5/16" INSULATING LAMINATED INFILL
Elevation
OUTSIDE SET SYSTEM (Wet or Dry Glazed)
Horizontal Details:
H5401 Head
H5403 Intermediate Horizontal
H5405 Sill - Option 1
H5408 Sill - Option 4
H5411 Head - Inverted System - Option 1
H5412 Head - Inverted System - Option 2
H5413 Intermediate Horizontal - Inverted
System
H5414 Sill - Inverted System
H5420 Head - Pre-Glaze Option
H5422 Sill - Pre-Glaze Option
Vertical Details:
V5401 Jamb
V5403 Typical Vertical
V5406 Heavy Vertical - Option 1
V5409 Expansion Vertical
V5410 Cripple Vertical
V5411 Heavy Cripple Vertical
V5415 Jamb - 5"
V5417 5" Vertical
V5418 5" Vertical w/ Aluminum Reinforcement
V5420 5" Cripple Vertical
Corner Details:
V5432 90° Outside Corner - Option 1
V5433 90° Outside Corner - Option 2
V5434 90° Inside Corner - Option 1
V5435 90° Inside Corner - Option 2
V5436 135° Outside Corner
V5437 135° Inside Corner
INSIDE SET SYSTEM (Dry Glazed Only)
Horizontal Details:
H5451 Head
H5453 Intermediate Horizontal
H5454 Sill
Vertical Details:
V5451 Jamb
V5453 Typical Vertical
V5456 Heavy Vertical
V5459 Expansion Vertical
V5460 Cripple Vertical
V5461 Heavy Cripple Vertical
V5465 5" Jamb
V5467 5" Vertical
V5468 5" Vertical w/ Aluminum Reinforcement
V5470 5" Cripple Vertical
Corner Details:
V5482 90° Outside Corner - Option 1
V5483 90° Outside Corner - Option 2
V5484 90° Inside Corner - Option 1
V5485 90° Inside Corner - Option 2
V5486 135° Outside Corner
V5487 135° Inside Corner
MISC. DETAILS
M5201 Sub Sill Splicing and Fabricating for
End Dams
Table of Contents
1-866-Oldcastle (653-2278) - www.obe.com
1-866-OLDCASTLE (653-2278) www.obe.com0-FG5750T-StormMax-TOC
January 2021A
(Drawing numbers---i.e., H5401---used as CAD detail reference only)
NOTE: EACH CUSTOMER, WHETHER DIRECTLY OR THROUGH THE PROFESSIONAL ENGINEERING EXPERTISE OF ITS OWN ENGINEER OR THAT OF THE
ENGINEER OF RECORD, ASSUMES ALL LIABILITY FOR DETERMINING THE APPLICABILITY OF THE APPROPRIATE STATE BUILDING CODE FOR EACH PROJECT.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax® Wet & Dry Glazed Hurricane Resistant Storefront
2-1/2" x 5" w/ 1-5/16" Insulating Laminated Infill - Elevation
Elev-FG5750T-StormMaxJanuary 2021A
H5401
OUTSIDE SET
MAY BE WET OR DRY GLAZED
H5403
V5401
V5403
TYP.
V5406
V5409
EXPANSION.
V5410
CRIPPLE
V5411
HEAVY CRIPPLE
M5201
SUB SILL SPLICING &
FABRICATING FOR END DAM
V5432
O.S. 90° OPT. 1
V5433
O.S. 90° OPT. 2
V5434
V5435
I.S. 90° OPT. 1
I.S. 90° OPT. 2
H5405
SILL, OPTION 1
H5408
SILL, OPTION 2
H5411
INVERTED SYSTEM, OPTION 1
H5412
INVERTED SYSTEM, OPTION 2
H5413
INVERTED SYSTEM
H5414
INVERTED SYSTEM
H5420
PRE-GLAZED OPTION
H5422
PRE-GLAZED OPTION
V5417
5" MULLION
V5415
5" JAMB
V5420
5" CRIPPLE
OPP.
V5418
5" MULLION W/ ALUM. REINF.
HEAVY DUTY
V5436
O.S. 135°
V5437
I.S. 135°
H5451
INSIDE SET
NOTE: AVAILABLE AS DRY GLAZED ONLY
H5453
H5454
V5451
V5453
TYP.
V5456
V5459
EXPANSION.
V5460
CRIPPLE
V5461
HEAVY CRIPPLE
M5201
SUB SILL SPLICING &
FABRICATING FOR END DAM
V5482
O.S. 90° OPT. 1
V5483
O.S. 90° OPT. 2
V5484
V5485
I.S. 90° OPT. 1
I.S. 90° OPT. 2
V5467
5" MULLION
V5465
5" JAMB
V5470
5" CRIPPLE
OPP.
V5468
5" MULLION W/ ALUM. REINF.
HEAVY DUTY
V5486
O.S. 135°
V5487
I.S. 135°
TYP.
TYP.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Head - Outside Glazed - H5401
H5401-Head-OutsideGlzJanuary 2021A
FGT-5770 HEAD
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS)
SM5601 1/2" JOINT
SEALANT TAPE
FG-5731
SPACER
GASKET &
STRUCT.
SILICONE
SEALANT
(SEALANT BY
OTHERS)
FG-5730
EXTERIOR
GASKET
1/4
" M
IN
.
1/2
" M
AX
.
3/8
" S
HO
WN
2 1
/2
"D
.L
.O
.
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-5/16" INSULATING
LAMINATED GLAZING
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Intermediate Horizontal - Outside Glazed - H5403
H5403-Intermediate-Horizontal-OutsideGlzJanuary 2021A
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730
EXTERIOR
GASKETS
FG-5760
GLASS STOP
SM5601 1/2" JOINT
SEALANT TAPE
1-5/16" INSULATING
LAMINATED GLAZING ON
FG-5743 SETTING BLOCKS
FG-5790-02 WATER
DIVERTER,
BED IN SEALANT
2 1
/2
"D
.L
.O
.D
.L
.O
.
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
FGT-5772
HORIZONTAL
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Sill - Attachment Option 1 - Outside Glazed - H5405
H5405-Sill-Opt1-OutsideGlzJanuary 2021A
FGT-5771 SILL
2 1/2"
D.L.O
.
5"
5/8"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5760
GLASS STOP
SM5601 1/2" JOINT
SEALANT TAPE
FG-5721-01
SETTING CHAIR
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS)
FG-5730 EXTERIOR
GASKET
FGT-5712 SILL
RECEPTOR
CONT. SEAL
(BY OTHERS)
ATTACH SILL TO
RECEPTOR W/ FS-27,
(2) PER D.L.O.
SPACED 1-1/2" FROM
EDGES OF VERTICALS
ACCESS HOLE
1/4" WEEP HOLES,
LOCATE @ MID-LITE
AND 3" FROM SPLICE
JOINT (BOTH SIDES).
AN-101-01 END DAM,
SET IN SEALANT & ATTACH W/ (2)
FS-23. SEE DETAIL M5201 FOR
FABRICATION FOR END DAM
1-5/16" INSULATING
LAMINATED GLAZING ON
FG-5743 SETTING BLOCKS
1/4" M
IN
.
1/2" M
AX
.
3/8" S
HO
WN
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Sill - Attachment Option 2 - Outside Glazed - H5408
H5408-Sill-Opt2-OutsideGlzJanuary 2021A
FGT-5771 SILL
2 1/2"
D.L.O
.
5"
5/8"
1/4" M
IN
.
1/2" M
AX
.
3/8" S
HO
WN
FG-5731 SPACER
GASKETS & STRUCT.
SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5760
GLASS STOP
FG-5721-01
SETTING CHAIR
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
FG-5730 EXTERIOR
GASKET
1/4" WEEP HOLES,
LOCATE @ MID-LITE AND
3" FROM SPLICE JOINTS
(BOTH SIDES). DRILL
INTO REAR CHAMBER
OF SILL RECPTOR.
AN-101-01 END DAM,
SET IN SEALANT & ATTACH W/ (2)
FS-23. SEE DETAIL M5201 FOR
FABRICATION FOR END DAM
1-5/16" INSULATING
LAMINATED GLAZING ON
FG-5743 SETTING BLOCKS
ATTACH SILL TO
RECEPTOR W/ FS-229,
(2) PER D.L.O.
SPACED 1-1/2" FROM
EDGES OF VERTICALS
SM5601 1/2" JOINT
SEALANT TAPE
ANCHOR BOLT
(BY OTHERS)
FGT-5712 SILL
RECEPTOR
CONT. SEAL
(BY OTHERS)
ACCESS HOLE,
PATCH AND SEAL OVER
AFTER ANCHOR BOLT
INSTALLATION.
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Head - Outside Glazed - Inverted System - Option 1 - H5411
H5411-Head-Inverted-Opt1-OutsideGlzJanuary 2021A
FGT-5771 HEAD
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS)
SM5601 1/2" JOINT
SEALANT TAPE
FG-5731
SPACER
GASKET &
STRUCT.
SILICONE
SEALANT
(SEALANT BY
OTHERS)
FG-5730
EXTERIOR
GASKET
1/4
" M
IN
.
1/2
" M
AX
.
3/8
" S
HO
WN
2 1
/2
"D
.L
.O
.
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-5/16" INSULATING
LAMINATED GLAZING
FG-5760
GLASS STOP
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Head - Outside Glazed - Inverted System - Option 2 - H5412
H5412-Head-Inverted-Opt2-OutsideGlzJanuary 2021A
FGT-5771 HEAD
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS)
SM5601 1/2" JOINT
SEALANT TAPE
FG-5731
SPACER
GASKET &
STRUCT.
SILICONE
SEALANT
(SEALANT BY
OTHERS)
FG-5730
EXTERIOR
GASKET
1/4
" M
IN
.
1/2
" M
AX
.
3/8
" S
HO
WN
2 1
/2
"D
.L
.O
.
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-5/16" INSULATING
LAMINATED GLAZING
FG-5760
GLASS STOP
ACCESS
HOLE
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Intermediate Horizontal - Outside Glazed - Inverted System - H5413
H5413-Intermediate-Horizontal-Inverted-OutsideGlzJanuary 2021A
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730
EXTERIOR
GASKETS
FG-5760
GLASS STOP
SM5601 1/2" JOINT
SEALANT TAPE
1-5/16" INSULATING
LAMINATED GLAZING ON
FG-5763 SETTING BLOCKS
FG-5790-02 WATER
DIVERTER,
NOTCH AS NEEDED
TO CLEAR THERMAL
BREAK AND BED IN
SEALANT.
2 1
/2
"D
.L
.O
.D
.L
.O
.
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
FGT-5772
HORIZONTAL
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Sill - Inverted System - H5414
H5414-Sill-Inverted-OutsideGlzJanuary 2021A
FGT-5770 SILL
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
SM5601 1/2" JOINT
SEALANT TAPE
2 1/2"
D.L.O
.
AN-101-01 END DAM,
SET IN SEALANT & ATTACH W/
(2) FS-23. SEE DETAIL M5201
FOR FASTENER LAYOUT
FG-5730 EXTERIOR
GASKET
5"
1-5/16" INSULATING
LAMINATED GLAZING ON
FG-5743 SETTING BLOCKS
CONT. SEAL
(BY OTHERS)
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
FG-5723-01
SETTING
CHAIR
5/8"
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
1/4" WEEP HOLES,
LOCATE @ MID-LITE
AND 3" FROM
SPLICE JOINT (BOTH
SIDES). DRILL INTO
REAR CHAMBER OF
SILL RECEPTOR.
FGT-5712 SILL
RECEPTOR
ACCESS HOLE,
PATCH AND SEAL
OVER AFTER ANCHOR
BOLT INSTALLATION.
ANCHOR BOLT
(BY OTHERS)
FG-5715 SILL ANCHOR,
ATTACH TO SILL
RECEPTOR W/ FS-27,
FASTENER SPACING PER
STRUCTURAL REVIEW
1/4" M
IN
.
1/2" M
AX
.
3/8" S
HO
WN
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Head - Pre-glazed - H5420
H5420-Head-PreGlazedJanuary 2021A
FGT-5786 HEAD
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS)
SM5601 1/2" JOINT
SEALANT TAPE
FG-5731 SPACER GASKET &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730
EXTERIOR
GASKET
1/2
"2
1
/2
"D
.L
.O
.
5"
1-5/16" INSULATING
LAMINATED GLAZING
FGT5788-01
ANCHOR PLATE,
RUN FG-5715 FLAT
FILLER BETWEEN.
5/1
6"
ATTACH HEAD TO
ANCHOR W/ FS-336,
SPACING PER
STRUCTURAL
REQUIREMENTS.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Sill - Pre-glazed - H5422
H5422-Sill-PreGlazedJanuary 2021A
FG-5259 COVER
2 1/2"
D.L.O
.
5"
5/8"
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5760
GLASS STOP
SM5601 1/2" JOINT
SEALANT TAPE
FG-5721-01
SETTING CHAIR
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS)
FG-5730 EXTERIOR
GASKET
FGT-5712 SILL
RECEPTOR
CONT. SEAL
(BY OTHERS)
1/4" WEEP HOLES,
LOCATE @ MID-LITE
AND 3" FROM SPLICE
JOINTS (BOTH SIDES).
DRILL INTO REAR WALL
OF SILL RECEPTOR
AN-101-01 END DAM,
SET IN SEALANT & ATTACH W/ (2)
FS-23. SEE DETAIL M5201 FOR
FABRICATION FOR END DAM
1-5/16" INSULATING
LAMINATED GLAZING ON
FG-5743 SETTING BLOCKS
FGT-5787 SILL
ATTACH SILL TO SILL
RECEPTOR W/ FS-128
1/4" M
IN
.
1/2" M
AX
.
3/8" S
HO
WN
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Jamb - Outside Glazed - V5401
V5401-Jamb-OutsideGlzJanuary 2021A
FGT-5770 JAMB
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
AN-101-1 END DAM @ SILL,
SET IN SEALANT & ATTACH TO
SILL RECEPTOR W/ (2) FS-23.
SEE DETAIL M5201 FOR
FABRICATION FOR END DAM.
2 1/2"
1/8"
1/4" MIN.
1/2" MAX.
3/8" SHOWN
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS, AS
STRUCTURALLY
REQUIRED)
FS-8 ASS'Y
FASTENER TYP.
FG-5731 SPACER GASKET &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730 EXTERIOR
GASKET
1-5/16" INSULATING
LAMINATED GLAZING
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
D.L.O.
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
5"
FG-5715 FILLER
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Typical Vertical - Outside Glazed - V5403
V5403-Vert-Typ-OutsideGlzJanuary 2021A
FGT-5773 MULLION
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
2 1/2"
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
D.L.O.
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENER TYP.
D.L.O.
FGT-5780 FILLER
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-5/16" INSULATING
LAMINATED GLAZING
FG-5730 EXTERIOR
GASKETS
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Heavy Vertical - Outside Glazed - V5406
V5406-Vert-Hvy-OutsideGlzJanuary 2021A
FGT-5774 MULLION
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
2 1/2"
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
D.L.O.
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENER TYP.
D.L.O.
FGT-5780 FILLER
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-5/16" INSULATING
LAMINATED GLAZING
FG-5730 EXTERIOR
GASKETS
ACCESS
HOLES
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Expansion Vertical - Outside Glazed - V5409
V5409-Expansion-Vertical-OutsideGlzJanuary 2021A
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
FS-8 ASS'Y
FASTENER TYP.
D.L.O.
1-5/16" INSULATING
LAMINATED GLAZING
FG-5730 EXTERIOR
GASKETS
D.L.O.
FGT-5783 FGT-5782
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5731 SPACER
GASKETS & STRUCT.
SILICONE SEALANT
(SEALANT BY OTHERS)
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
CW-998 BULB GASKETS,
FRONT & BACK
2 3/4"
ACCESS
HOLES
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Cripple Vertical - Outside Glazed - V5410
V5410-Vert-Cripple-OutsideGlzJanuary 2021A
FGT-5773 MULLION
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
2 1/2"
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
D.L.O.
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENER TYP.
D.L.O.
FGT-5780 FILLER
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-5/16" INSULATING
LAMINATED GLAZING
FG-5730 EXTERIOR
GASKETS
BREAK POINT OF
FS-56 SCREW TO FIT.
FG-5714-01 SHEAR BLOCK,
ATTACH TO VERTICAL W/
FS-56, ATTACH TO BOTTOM OF
UPPER HORIZONTAL W/ FS-96.
SHOP NOTCH P&D
AREAS OF MULLION &
FILLER TO CLEAR
SHEAR BLOCK
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Cripple Heavy Vertical - Outside Glazed - V5411
V5411-Vert-Heavy-Cripple-OutsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
2 1/2"
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
D.L.O.
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENER TYP.
D.L.O.
FGT-5780 FILLER
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-5/16" INSULATING
LAMINATED GLAZING
FG-5730 EXTERIOR
GASKETS
BREAK POINT OF
FS-56 SCREW TO FIT.
FG-5714-01 SHEAR BLOCK,
ATTACH TO VERTICAL W/
FS-56, ATTACH TO BOTTOM OF
UPPER HORIZONTAL W/ FS-96.
FGT-5774 MULLION
SHOP NOTCH VERTICAL
WALLS AND P&D AREAS TO
CLEAR SHEAR BLOCK.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
5"Jamb - Outside Glazed - V5415
V5415-Jamb-5in-OutsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5731 SPACER
GASKET & STRUCT.
SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730 EXTERIOR
GASKETS
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
FGT-5779 MULLION HALF
FGT-5778 MULLION HALF
5" D.L.O.
5"
FS-8 ASS'Y
FASTENERS TYP.
1-5/16" INSULATING
LAMINATED GLAZING
SEE INTERMEDIATE
HORIZONTAL
DETAIL FOR WATER
DIVERTER INFO
AN-101-1 END DAM @ SILL,
SET IN SEALANT & ATTACH TO
SILL RECEPTOR W/ (2) FS-23.
SEE DETAIL M5201 FOR
FABRICATION FOR END DAM.
1/8"
1/4" MIN.
1/2" MAX.
3/8" SHOWN
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS, AS
STRUCTURALLY
REQUIRED)
CH-55 @ ANCHOR
LOCATIONS,
LENGTH DETERMINED
PER STRUCTURAL
REQUIREMENTS.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
5" Vertical - Outside Glazed - V5417
V5417-Vert-5in-OutsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5731 SPACER
GASKET & STRUCT.
SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730 EXTERIOR
GASKETS
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
FS-8 ASS'Y
FASTENERS TYP.
1-5/16" INSULATING
LAMINATED GLAZING
SEE INTERMEDIATE
HORIZONTAL
DETAIL FOR WATER
DIVERTER INFO
FGT-5779 MULLION HALF
FGT-5778 MULLION HALF
5" D.L.O.D.L.O.
5"
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
5" Vertical w/ Alum. Reinforcement - Outside Glazed - V5418
V5418-Vert-5in-w-Alum-Reinf-OutsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5731 SPACER
GASKET & STRUCT.
SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730 EXTERIOR
GASKETS
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
FS-8 ASS'Y
FASTENERS TYP.
1-5/16" INSULATING
LAMINATED GLAZING
SEE INTERMEDIATE
HORIZONTAL
DETAIL FOR WATER
DIVERTER INFO
FGT-5779 MULLION HALF
FGT-5778 MULLION HALF
5" D.L.O.D.L.O.
5"
FG-5720 ALUM. REINFORCEMENT,
ATTACH W/ (2) FS8, LOCATED 1-1/4"
FROM EACH END OF VERTICALS.
NOTE: REINFORCEMENT
ATTACHMENT LOCATION
MAY NEED TO BE SHIFTED
DEPENDING ON HEAD
AND/OR SILL BEING USED.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
5" Cripple Vertical - Outside Glazed - V5420
V5420-Vert-5in-Cripple-OutsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5731 SPACER
GASKET & STRUCT.
SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730 EXTERIOR
GASKETS
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
FS-8 ASS'Y
FASTENERS TYP.
1-5/16" INSULATING
LAMINATED GLAZING
SEE INTERMEDIATE
HORIZONTAL
DETAIL FOR WATER
DIVERTER INFO
5" D.L.O.D.L.O.
5"
FG-5714-01 SHEAR BLOCKS,
ATTACH TO VERTICAL W/
FS-56, ATTACH TO BOTTOM OF
UPPER HORIZONTAL W/ FS-96.
NOTCH P&D
AT SHEAR
BLOCK
LOCATIONS
FGT-5779 MULLION HALF
FGT-5778 MULLION HALF
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
90° Outside Corner - Option 1 - Outside Glazed - V5432
V5432-90-Outside-Corner-Opt1-OutsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FGT-5706
CORNER
MULLION
ATTACH FILLERS
TO MULLION W/
FS-58 @ 18" O.C.
(STAGGERED) AND
2" FROM D.L.O.
5 1/2" D.L.O.
5"
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730 EXTERIOR
GASKETS
1-5/16" INSULATING
LAMINATED GLAZING
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FGT-5780 FILLERS
FS-8 ASS'Y
FASTENERS TYP.
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
90° Outside Corner - Option 2 - Outside Glazed - V5433
V5433-90-Outside-Corner-Opt2-OutsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FGT-5784
MULLION HALF
5" D.L.O.
5"
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENERS TYP.
FG-5730 EXTERIOR
GASKETS
1-5/16" INSULATING
LAMINATED GLAZING
FGT-5778
MULLION HALF
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
90°Inside Corner - Option 1 - Outside Glazed - V5434
V5434-90-Inside-Corner-Opt1-OutsideGlzJanuary 2021A
FGT-5706
CORNER MULLION
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FGT-5780 FILLERS
FS-8 ASS'Y
FASTENERS TYP.
ATTACH FILLERS
TO MULLION W/
FS-58 @ 18" O.C.
(STAGGERED) AND
2" FROM D.L.O.
1-5/16" INSULATING
LAMINATED GLAZING
FG-5730 EXTERIOR
GASKETS
5" 1/2" D.L.O.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
90° Inside Corner - Option 2 - Outside Glazed - V5435
V5435-90-Inside-Corner-Opt2-OutsideGlzJanuary 2021A
FGT-5779
MULLION HALF
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-5/16" INSULATING
LAMINATED GLAZING
FGT-5785
MULLION HALF
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5731 SPACER GASKETS &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENERS TYP.
FG-5730 EXTERIOR
GASKETS
5" D.L.O.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
135° Outside Corner - Outside Glazed - V5436
V5436-135-Outside-Corner-OutsideGlzJanuary 2021A
FS-8 ASS'Y
FASTENER TYP.
1-5/16" INSULATING
LAMINATED GLAZING
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FGT-5781
FILLERS
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FG-5731 SPACER GASKET &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730
EXTERIOR
GASKETS
ATTACH FILLERS TO
MULLION W/ FS-58 @ 9"
O.C. (STAGGERED) AND
2" FROM EACH D.L.O.
FGT-5707 CORNER
MULLION
3" D.L.O.
5"
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
135° Inside Corner - Outside Glazed - V5437
V5437-135-Inside-Corner-OutsideGlzJanuary 2021A
FS-8 ASS'Y
FASTENER TYP.
1-5/16" INSULATING
LAMINATED GLAZING
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FGT-5780
FILLERS
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FG-5731 SPACER GASKET &
STRUCT. SILICONE SEALANT
(SEALANT BY OTHERS)
FG-5730
EXTERIOR
GASKETS
ATTACH FILLERS TO
MULLION W/ FS-58 @ 9"
O.C. (STAGGERED) AND
2" FROM EACH D.L.O.
FGT-5707 CORNER
MULLION
DRY GLAZED OPTION
FG-5732 INTERIOR GASKET
FG-5730 EXTERIOR GASKET
5"
3"D.L.O.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Head - Inside Glazed - H5451
H5451-Head-InsideGlzJanuary 2021A
FGT-5771 HEAD
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS)
SM5601
1/2" JOINT
SEALANT
TAPE
FG-5732
EXTERIOR
GASKET
FG-5730
INTERIOR
GASKET
1/4
" M
IN
.
1/2
" M
AX
.
3/8
" S
HO
WN
2 1
/2
"D
.L
.O
.
5"
1-5/16" INSULATING
LAMINATED GLAZING
FG-5760
GLASS STOP
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Intermediate Horizontal - Inside Glazed - H5453
H5453-Intermediate-Horizontal-InsideGlzJanuary 2021A
FG-5732
EXTERIOR
GASKETS
FG-5730
INTERIOR
GASKETS
FG-5760
GLASS STOP
SM5601 1/2" JOINT
SEALANT TAPE
1-5/16" INSULATING
LAMINATED GLAZING ON
FG-5763 SETTING BLOCKS
FG-5790-02 WATER DIVERTER,
NOTCH AS NEEDED TO CLEAR
THERMAL BREAK AND BED IN
SEALANT.
2 1
/2
"D
.L
.O
.D
.L
.O
.
5"
FGT-5772
HORIZONTAL
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Sill - Inside Glazed - H5454
H5454-Sill-InsideGlzJanuary 2021A
FG-5770 SILL
FG-5730 INTERIOR
GASKET
2 1/2"
D.L.O
.
AN-101-01 END DAM,
SET IN SEALANT & ATTACH W/
(2) FS-23. SEE DETAIL M5201
FOR FASTENER LAYOUT
FG-5732 EXTERIOR
GASKET
5"
1-5/16" INSULATING
LAMINATED GLAZING ON
FG-5743 SETTING BLOCKS
CONT. SEAL
(BY OTHERS)
FG-5723-01
SETTING
CHAIR
5/8"
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
1/4" WEEP HOLES,
LOCATED @ MID-LITE
AND 3" FROM SPLICE
JOINTS (BOTH SIDES).
DRILL INTO REAR
CHAMBER OF SILL
RECEPTOR.
FGT-5712 SILL
RECEPTOR
ACCESS HOLE,
PATCH AND SEAL
OVER AFTER ANCHOR
BOLT INSTALLATION.
ANCHOR BOLT
(BY OTHERS)
FG-5715 SILL ANCHOR,
ATTACH TO SILL
RECEPTOR W/ FS-27,
FASTENER SPACING PER
STRUCTURAL REVIEW
1/4" M
IN
.
1/2" M
AX
.
3/8" S
HO
WN
SM-5601 1/2" JOINT
SEALANT TAPE
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Jamb - Inside Glazed - V5451
V5451-Jamb-InsideGlzJanuary 2021A
FGT-5770 JAMB
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
AN-101-1 END DAM @ SILL,
SET IN SEALANT & ATTACH TO
SILL RECEPTOR W/ (2) FS-23.
SEE DETAIL M5201 FOR
FABRICAT ION FOR END DAM.
2 1/2"
1/8"
1/4" MIN.
1/2" MAX.
3/8" SHOWN
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS, AS
STRUCTURALLY
REQUIRED)
FS-8 ASS'Y
FASTENER TYP.
FG-5732 EXTERIOR
GASKET
FG-5730 INTERIOR
GASKET
1-5/16" INSULATING
LAMINATED GLAZING
D.L.O.
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
5"
FG-5715
FLAT FILLER
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Typical Vertical - Inside Glazed - V5453
V5453-Vert-Typ-InsideGlzJanuary 2021A
FGT-5773 MULLION
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
2 1/2"
FG-5732 EXTERIOR
GASKETS
D.L.O.
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENER TYP.
D.L.O.
FGT-5780 FILLER
5"
1-5/16" INSULATING
LAMINATED GLAZING
FG-5730 INTERIOR
GASKETS
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Heavy Vertical - Inside Glazed - V5456
V5456-Vert-Hvy-InsideGlzJanuary 2021A
FGT-5774 MULLION
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
2 1/2"
FG-5732 EXTERIOR
GASKETS
D.L.O.
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENER TYP.
D.L.O.
FGT-5780
FILLER
5"
1-5/16" INSULATING
LAMINATED GLAZING
FG-5730 INTERIOR
GASKETS
ACCESS
HOLES
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Expansion Vertical - Inside Glazed - V5459
V5459-Expansion-Vertical-InsideGlzJanuary 2021A
5"
FS-8 ASS'Y
FASTENER TYP.
D.L.O.
1-5/16" INSULATING
LAMINATED GLAZING
FG-5730INTERIOR
GASKETS
D.L.O.
FGT-5783 FGT-5782
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5732 EXTERIOR
GASKETS
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
CW-998 BULB GASKETS,
FRONT & BACK
2 3/4"
ACCESS
HOLES
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Cripple Vertical - Inside Glazed - V5460
V5460-Vert-Cripple-InsideGlzJanuary 2021A
FGT-5773 MULLION
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
2 1/2"
FG-5732 EXTERIOR
GASKETS
D.L.O.
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENER TYP.
D.L.O.
FGT-5780
FILLER
5"
1-5/16" INSULATING
LAMINATED GLAZING
FG-5730 INTERIOR
GASKETS
BREAK POINT OF
FS-56 SCREW TO FIT.
FG-5714-01 SHEAR BLOCK,
ATTACH TO VERTICAL W/) FS-56,
ATTACH TO TOP OF LOWER
HORIZONTAL W/ FS-96.
SHOP NOTCH P&D
AREAS OF MULLION
& FILLER TO CLEAR
SHEAR BLOCK
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
Cripple Heavy Vertical - Inside Glazed - V5461
V5461-Vert-Heavy-Cripple-InsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
2 1/2"
FG-5730 INTERIOR GASKETS
D.L.O.
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENER TYP.
D.L.O.
FGT-5780
FILLER
5"
1-5/16" INSULATING
LAMINATED GLAZING
FG-5732 EXTERIOR
GASKETS
BREAK POINT OF
FS-56 SCREW TO FIT.
FG-5714-01 SHEAR BLOCK,
ATTACH TO VERTICAL W/ FS-56,
ATTACH TO TOP OF LOWER
HORIZONTAL W/ FS-96.
FGT-5774 MULLION
SHOP NOTCH VERTICAL
WALLS AND P&D AREAS TO
CLEAR SHEAR BLOCK.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
5"Jamb - Inside Glazed - V5465
V5465-Jamb-5in-InsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5730 INTERIOR
GASKETS
FG-5732 EXTERIOR
GASKETS
FGT-5779 MULLION HALF
FGT-5778 MULLION HALF
5" D.L.O.
5"
FS-8 ASS'Y
FASTENERS TYP.
1-5/16" INSULATING
LAMINATED GLAZING
SEE INTERMEDIATE
HORIZONTAL
DETAIL FOR WATER
DIVERTER INFO
AN-101-1 END DAM @ SILL,
SET IN SEALANT & ATTACH TO
SILL RECEPTOR W/ (2) FS-23.
SEE DETAIL M5201 FOR
FABRICATION FOR END DAM.
1/8"
1/4" MIN.
1/2" MAX.
3/8" SHOWN
SHIM, BACKER
ROD & SEALANT
(BY OTHERS)
ANCHOR BOLT
(BY OTHERS, AS
STRUCTURALLY
REQUIRED)
CH-55 @ ANCHOR
LOCATIONS,
LENGTH DETERMINED
PER STRUCTURAL
REQUIREMENTS.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
5" Vertical - Inside Glazed - V5467
V5467-Vert-5in-InsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5730 INTERIOR
GASKETS
FG-5732 EXTERIOR
GASKETS
FS-8 ASS'Y
FASTENERS TYP.
1-5/16" INSULATING
LAMINATED GLAZING
SEE INTERMEDIATE
HORIZONTAL
DETAIL FOR WATER
DIVERTER INFO
FGT-5779 MULLION HALF
FGT-5778 MULLION HALF
5" D.L.O.D.L.O.
5"
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
5" Vertical w/ Alum. Reinforcement - Inside Glazed - V5468
V5468-Vert-5in-w-Alum-Reinf-InsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5730 INTERIOR
GASKETS
FG-5732 EXTERIOR
GASKETS
FS-8 ASS'Y
FASTENERS TYP.
1-5/16" INSULATING
LAMINATED GLAZING
SEE INTERMEDIATE
HORIZONTAL
DETAIL FOR WATER
DIVERTER INFO
FGT-5778 MULLION HALF
FGT-5779 MULLION HALF
5" D.L.O.D.L.O.
5"
FG-5720 ALUM. REINFORCEMENT,
ATTACH W/ (2) FS8, LOCATED 1-1/4"
FROM EACH END OF VERTICALS.
NOTE: REINFORCEMENT
ATTACHMENT LOCATION
MAY NEED TO BE SHIFTED
DEPENDING ON HEAD
AND/OR SILL BEING USED.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
5" Cripple Vertical - Inside Glazed - V5470
V5470-Vert-5in-Cripple-InsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5730 INTERIOR
GASKETS
FG-5732 EXTERIOR
GASKETS
FS-8 ASS'Y
FASTENERS TYP.
1-5/16" INSULATING
LAMINATED GLAZING
SEE INTERMEDIATE
HORIZONTAL
DETAIL FOR WATER
DIVERTER INFO
5" D.L.O.D.L.O.
5"
FG-5714-01 SHEAR BLOCKS,
ATTACH TO VERTICAL W/
FS-56, ATTACH TO TOP OF
LOWER HORIZONTAL W/ FS-96.
FGT-5778 MULLION HALF
FGT-5779 MULLION HALF
NOTCH P&D
AT SHEAR
BLOCK
LOCATIONS
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
90° Outside Corner - Option 1 - Inside Glazed - V5482
V5482-90-Outside-Corner-Opt1-InsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FGT-5706
CORNER
MULLION
ATTACH FILLERS
TO MULLION W/
FS-58 @ 18" O.C.
(STAGGERED) AND
2" FROM D.L.O.
5 1/2" D.L.O.
5"
FG-5730 INTERIOR
GASKETS
FG-5732 EXTERIOR
GASKETS
1-5/16" INSULATING
LAMINATED GLAZING
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FGT-5780 FILLERS
FS-8 ASS'Y
FASTENERS TYP.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
90° Outside Corner - Option 2 - Inside Glazed - V5483
V5483-90-Outside-Corner-Opt2-InsideGlzJanuary 2021A
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FGT-5779
MULLION HALF
5" D.L.O.
5"
FGT-5785
MULLION HALF
FG-5730 INTERIOR
GASKETS
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENERS TYP.
FG-5732 INTERIOR
GASKETS
1-5/16" INSULATING
LAMINATED GLAZING
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
90°Inside Corner - Option 1 - Inside Glazed - V5484
V5484-90-Inside-Corner-Opt1-InsideGlzJanuary 2021A
FGT-5706
CORNER MULLION
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5730 INTERIOR
GASKETS
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FGT-5780 FILLERS
FS-8 ASS'Y
FASTENERS TYP.
ATTACH FILLERS
TO MULLION W/
FS-58 @ 18" O.C.
(STAGGERED) AND
2" FROM D.L.O.
1-5/16" INSULATING
LAMINATED GLAZING
FG-5732 EXTERIOR
GASKETS
5" 1/2" D.L.O.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
90° Inside Corner - Option 2 - Inside Glazed - V5485
V5485-90-Inside-Corner-Opt2-InsideGlzJanuary 2021A
FGT-5778
MULLION HALF
1-5/16" INSULATING
LAMINATED GLAZING
FGT-5784
MULLION HALF
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FG-5730 INTERIOR
GASKETS
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FS-8 ASS'Y
FASTENERS TYP.
FG-5732 EXTERIOR
GASKETS
5" D.L.O.
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
135° Outside Corner - Inside Glazed - V5486
V5486-135-Outside-Corner-InsideGlzJanuary 2021A
FS-8 ASS'Y
FASTENER TYP.
1-5/16" INSULATING
LAMINATED GLAZING
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FGT-5780
FILLERS
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FG-5730 INTERIOR
GASKETS
FG-5732
EXTERIOR
GASKETS
ATTACH FILLERS TO
MULLION W/ FS-58 @ 9"
O.C. (STAGGERED) AND
2" FROM EACH D.L.O.
FGT-5707
CORNER MULLION
3" D.L.O.
5"
1-866-OLDCASTLE (653-2278) www.obe.com
FG-5750T StormMax®
135° Inside Corner - Inside Glazed - V5487
V5487-135-Inside-Corner-InsideGlzJanuary 2021A
FS-8 ASS'Y
FASTENER TYP.
1-5/16" INSULATING
LAMINATED GLAZING
LINE OF SILL RECEPTOR BEYOND
LINE OF SILL RECEPTOR BEYOND
FGT-5781
FILLERS
SEE INTERMEDIATE
HORIZONTAL DETAIL FOR
WATER DIVERTER INFO
FG-5730 INTERIOR
GASKETS
FG-5732 EXTERIOR
GASKETS
ATTACH FILLERS TO MULLION W/
FS-58 @ 9" O.C. (STAGGERED)
AND 2" FROM EACH D.L.O.
FGT-5707 CORNER
MULLION
5"
3"D.L.O.
1-866-OLDCASTLE (653-2278) www.obe.com
StormMax® Storefronts
Sub Sill Splicing / End Dam Fabrication and Attachment - M5201
M5201-EndDam-Fab-SubSill-SplicingJanuary 2021A
FG-5712 (FG-5700 & 5750 StormMax® storefronts)FG-5180 (FG-5700 & 5750 StormMax® storefronts) FGT-5712 (5750T StormMax® storefront)
UW-466 2" WIDE SILICONE
SPLICE SHEET,
CUT TO FIT AND BED IN
SEALANT (TYP.)
1/2"
SPLICE
JOINT
UW-466 SILICONE SPLICE
SHEET, CUT TO FIT AND
BED IN SEALANT
MARRY SPLICE
JOINT SEAL W/
PERIMETER SEAL
AN-101-01 END DAM,
ATTACH W/ (2) FS-23
NOTES:
1. ATTACH END DAM TO FG/FGT-5712 SILL RECEPTOR THROUGH SCREW
SPLINES IN RECEPTOR. ATTACH END DAM TO FG-5180 SILL FLASHING
THROUGH BOTTOM LEG OF END DAM. SEE TYPICAL FABRICATION FOR
END DAMS ON THIS SHEET.
2. USE SM5601 JOINT SEALANT TAPE AT JOINERY OF SUB SILLS TO END
DAMS. SEE MANUAL FOR MORE INFO.
1/8" BETWEEN END
DAM AND JAMB
(CRITICAL)
FRONT VIEW
JAMB
SUB SILL
5.1250
3/32" 4 15/16"
Ø
9
/
6
4
"
D
R
I
L
L
T
H
R
U
(
2
)
P
L
A
C
E
S
17
/3
2"
FABRICATION FOR END DAM
ATTACHMENT TO FG/FGT-5712 SILL
RECEPTOR USING SCREW SPLINES
SUB SILL WIDTH
(FRAME WIDTH PLUS 1/4")
FG-5180 SILL
FLASHING
AN-101-01
END DAM
1 1
/8
"3
3
/3
2"
Ø
9
/
6
4
"
D
R
I
L
L
T
H
R
U
(
2
)
P
L
A
C
E
S
PLAN VIEW
MATCH DRILL THROUGH END
DAM FOR #6 FASTENER &
ATTACH W/ (2) FS-23. CAP
SEAL FASTENERS.
SIDE VIEW
FABRICATION OF FG-5180
SILL FLASHING FOR END DAM
ATTACHMENT
5/16"
SPLICING OF FG-5712
SILL RECEPTOR SHOWN,
FG-5180 FLASHING
SPLICE IS SIMILAR.