bunkers: qualifying quality a supplier's view of what really happens john stirling – world...
TRANSCRIPT
Bunkers: Qualifying Quality
A supplier's view of what really happens
John Stirling – World Fuel Services Quality ManagerJune, 2014
World Fuel Services Corporation
All figures, except employee count, are as of 12/31/12* Source: Fortune 500 Ranking Issue Date May 6, 2013** As of February 2013
▪ 2013 Revenue $41.6 billion▪ Market capitalization $3.28 billion▪ Stock symbol NYSE: INT▪ Fortune 500 Ranking* 74▪ Global headquarters Miami, Florida, USA▪ Founded 1984▪ Number of employees** 2,500
3
Global Presence with Over 60 Offices
Afghanistan
Australia
Argentina
Brazil
Canada
Chile
Colombia
Denmark
Germany
Gibraltar
Greece
Hong Kong
India
Japan
Kyrgyzstan
Mexico
Netherlands
Norway
Russia
Singapore
South Africa
South Korea
Taiwan
United Arab Emirates
United Kingdom
United States
SingaporeMiami London
WFS is #1 in market with 10% shareMillion MT
1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 20120.0
3.0
6.0
9.0
12.0
15.0
18.0
21.0
24.0
27.0
30.0
WFS Manages the Largest Bunker Volume
Marine Technical – who are we?
Five professionals with broad technical knowledge and marine educational backgrounds
About 180 years experience
• marine fuel and lubrication quality
• bunker fuel testing
• ship machinery and hull Inspection
• new ship construction
• project management
• marine consulting
• shipboard engineering
• marine engine design and construction
Bob Thornton
John Stirling
Dennis Eley
Marine Technical
Sea experience Multiple types of diesel and steam vessels
Members of ISO 8217 Marine Fuel Specifications Working Group
ISO 13739 - Bunkering Protocol Working Group
CIMAC Heavy Fuels Working Group
IMO's Marine Environmental Protection Committee
IBIA Board (International Bunker Industry Association)
Immediate past
Gajanan Pawar
Manuel Vinas
Technical Issues Facing the Industry
Frequency of fuel claims
• Quantity disputes both higher in number & Mt
• Related to high price of fuel
• Quality claims more complex – FTIR / GCMS
• Influence of the testing services
Technical Issues Facing the Industry
Environmental Legislation
• Proliferation of ECAs
• Rules and enforcement not uniform
• 2015 – Max 0.1% sulfur in an ECA
• 2020 – Max 0.5% sulfur global
• Scrubbers vs using LSGO or 0.5% LSFO if available
• Is LNG really the future?
Technical Issues Facing the Industry
Changing fuel quality • Suppliers blending to meet legislation v.s. spec• Law of unintended consequences
Typical concerns Quantity disputes
– Use of surveyors– Barge vs ship figures– Cappuccino – real or an excuse for sleeve oil– Vnet
Quality claims– Sulfur test accuracy– MARPOL vs Commercial testing– Study of “normal” bunkers– Debunkering may no longer be possible– Using what’s on board
Sulfur legislation– Revision of the EU Sulphur Directive– North American ECA : U.S. & Canada– Reports of detentions & fines in Europe & USA
Fuel quality – Is it really getting worse?– ISO 8217: 2005 vs 2010 vs 2012 vs Future– Blending to meet LSFO with MGO – Cost to meet sulfur specs with 95% & 99% certainty– Responsibility of the vessel to clean the fuel– Future availability – an educated guess
Sampling– MARPOL vs Commercial samples– Why suppliers insist on sampling on the barge– Why Owners want it on the vessel– What we’ve seen
Contractual requirements– Supplier’s terms of sale– Charter party clauses
Additional worries
WFS Bunker Claims - 2013
Split of Registered Claims - 2013
WFS Quality Claims - 2013
98.5% of products (MGO & IFO) delivered by WFS are free of claims Of the 1.5% having a claim, only 32% relate to quality Quality Claims = 32% of 1.5% or less than 0.5% of WFS deliveries WFS claims results are 50x lower than the 25% off-spec test results
cited by some test labs Some off spec not claimed?
Frequently the contractual sample is subsequently tested and found to be on-spec
Pay attention to the T&C sample! Since some WFS quality claims relate to experience from vessels, not
lab results, the difference is even higher Are we that good or is there some explanation for the extreme
difference?
Ask Anything!
But first – Since perception becomes truth Is the quality of bunkers really getting worse?
Are Catfines increasing dramatically as claimed by many?
Are Bunkers Getting Worse?
Courtesy of DNVPS
Focusing on Al+Si
Courtesy of DNVPS
A Dramatic Increase or?
Data - courtesy of DnVPS
Data - courtesy of DnVPS
An Accurate Depiction
Data - courtesy of DnVPS
Use of Truncated Graphs
Note that both of these graphs display identical data; however, in the truncated bar graph on the left, the data appear to show significant differences, whereas in the regular bar graph on the right, these differences are hardly visible.
ISO 2010/2012
ISO 2005
It’s not always the fuel
GC-MS Analysis
Quality – What’s in Bunkers
Sulphate SO4 - 534.6 mg/kg
(ppm)
Calcium Ca++ 208.0 mg/kg (ppm)
Chloride Cl - 68.0 mg/kg (ppm)
Magnesium Mg++ 53.5 mg/kg (ppm)
Sodium Na+ 42.0 mg/kg (ppm)
Potassium K+ 2.8 mg/kg (ppm)
Would you use this?
San Pellegrino Mineral Water
Sulphate BicarbonateCalciumChlorideMagnesiumSodiumSilica ResidueStrontiumPotassiumBoratesNitrateFluorideBromideLithium
SO4 –
HCO3 –
Ca++
Cl –
Mg++
Na+
SiO2
Sr++
K+
H3BO3
NO3 –
F –
Br –
Li+
534.6 mg/kg (ppm)222.7 mg/kg (ppm)208.0 mg/kg (ppm)68.0 mg/kg (ppm)53.5 mg/kg (ppm)42.0 mg/kg (ppm)9.4 mg/kg (ppm)3.5 mg/kg (ppm)2.8 mg/kg (ppm)1.2 mg/kg (ppm)0.77 mg/kg (ppm)0.61 mg/kg (ppm)0.40 mg/kg (ppm)0.18 mg/kg (ppm)
San Pellegrino Mineral Water
THE INTERNATIONAL COUNCIL ON COMBUSTION ENGINES
CIMAC is a worldwide non-profit association consisting of National Member Associations, National Member Groups and Corporate Members in 26 countries in America, Asia and Europe.
CIMAC covers diesel and gas engines and gas turbines which are used for power generation, marine propulsion and locomotives.
Worldwide members include engine manufacturers, engine users such as ship owners, component suppliers, fuel and lubricant companies, research organisations, classification societies, universities and other interested bodies.
www.cimac.com
Who we are• Engine manufacturers • Handling equipment manufacturers• Ship owners • Fuel analyst institutes• Classification societies • Fuel additive suppliers• Fuel suppliers
What we do Prepare recommendations for: • LSFO quality & operation • Bio fuels considerations• Combustion properties • Follow fuel quality worldwide• Fuel grade rationalization • Investigate different fuel compositions
Who we work withWe are a working group of experienced specialists within marine fuels, represented by the major players, and our goal is to prepare recommendations and make tools for the industry on how to operate on fuel, and choose fuels that will ensure safe operation of the diesel engines. Many CIMAC WG7 members also participate in ISO 8217 TC28/SC4/WG6 Marine Fuels
CIMAC WG7 - Fuels
CIMAC - Guide on Sulphur Testing
International Bunker ConferenceApril 3 & 4, 2014
Copenhagen
For the supplier, with a single test result
In the case of a maximum specification limit, the specification limit has been met, with 95% confidence, if the test result is less than or equal to the specification limit minus 0.59R.
• However, it is further given that this is for the guidance of the supplier, not an obligation, and that a value between the specification limit and the limit minus 0.59R is not proof that that the specification has not been met.
For the recipient, with a single test result
In the case of a maximum specification limit, the specification limit has not been met, with 95% confidence, if the test result is greater than the specification limit plus 0.59R.
• This means that the recipient with a single test result with a value above the specification limit but below the ‘limit plus 0.59R’ cannot claim that the specification has not been met and consequently has to accept that the product met the specification.
Interpreting a test result in accord with ISO 4259
The implications of ISO 4259 interpretationsThe Supplier• If a supplier intends to meet a particular maximum specified limit, they should
target a value at or below the specified limit. • If the supplier blended the fuel such that the ‘true value’ was equal to the
specified limit then there would be as many test results above the specified limit as there were below that limit (50/50)
• Therefore, despite all the care taken, there remains a slight chance that the result variation will be outside this ‘0.59R’ margin.
• The supplier has to accept the risk that any test result obtained by the supplier which exceeds the specified limit indicates that the product has not met that specification limit
The RecipientThe recipient can only consider that a maximum specified limit value has been exceeded if their test result exceeds the limit plus ‘0.59R’. There is the same chance that a result which indicated that the limit plus ‘0.59R’ had been exceeded is not supported by subsequent analysis. Such is the reality of fuel oil testing.
ISO 4259 Clear and unambiguous • Since all fuel oil testing is subject to inherent
variations, in commercial practice, the assessment of fuel oils as supplied is governed by the provisions of ISO 4259.
• This in essence requires that the supplier must not obtain a test result over the required specification limit value
• In contrast the receiver cannot consider a product out of specification unless it exceeds that value by more than the 95% confidence limit which, for a single test result, is given by the reproducibility of the test method multiplied by 0.59 (0.59R)
• This statistically based process, gives a clear and unambiguous finding with the necessary margin to allow for the reality of variations in test results.
The implications of ISO 4259 interpretations
Enforcement? Enforcement is inconsistent – confusingDifferent from country to country and even port to port
Bunkerworld 12th June 2014 11:11 GMT
Enforcement?
Rotterdam in the forefront….EMSA and Europe
“Follow Rotterdam model”
US? Chamber of Shipping America advice
A final distillate slide...
CP/CFPP/PP
39
CP
• Cloud point• Temperature at which dissolved particles precipitate and
form a cloudy appearance
CFPP
• Cold filter plugging point• Lowest temperature at which the fuel will pass through
a filter under specified conditions
PP• Pour point• Lowest temperature at which the fuel will flow
Courtesy of DNV Petroleum Services
Distillates are all very different.....
40
Courtesy of DNV Petroleum Services
41
Cloud Point (CP)/Pour Point (PP)
Definition : PPPour point is measured using ASTM D-97/ISO 3016 test method.Fuel suppliers typically set pour point specifications seasonally.It may not be possible to re-liquify a fuel that has gone solidFuel must be kept in storage at 5 centigrade degrees above its pour point at all times to reduce the risk of solidification.
CPMeasured using the ASTM D-2500/ISO 3015 test method. Generally, each diesel fuel supplier sets their own cloud point maximums which may vary seasonally.
Cold Filter Plugging Point (CFPP)
42
Definition : CFPPThe Cold Filter Plugging Point (CFPP) is the temperature at which a fuel will plug a
45-micron screen under prescribed test conditions. CFPP is measured using European Test Method IP 309, and is currently the most
commonly used cold-weather operability indicator.Although widely used, CFPP has its limitations.
(CFPP) ReductionThe CFPP of a typical diesel fuel can be reduced by the addition of kerosene. The maximum blending volume is limited by the effect kerosene will haveon specific physical and performance properties of the diesel fuel (eg flash, visc) As a general rule the diesel fuel CFPP can be reduced by about 10 C to 20 C for each 10% of added kerosine.
Geographically specific Hot and cold climatesArctic
Land Based? EN 590
43
What can the challenges look like...
44
Now you can ask anything!