bus cables · fixed installation, indoor 3x2x0.22 mm2 copper, bare (awg 24/7) pe whjbn, gnjrd,...

1
CONTROLS, INC. (800) 677-8942 I (303) 680-5159 Click or Call for a Quote! Data, Network and Bus Technology 1 HELUKABEL"' BUS-Cables BUS Cables I-BUS Type Cable structure Inner conductor diameter: Core insulation: Core colours: Stranding element: Shielding 1: Shielding 2: Total shielding: Outer sheath material: Cable external diameter: Outer sheath colour: Electrical data Characteristic impedance: Conductor resistance, max.: In su lation resistance, min.: Loop resistance: Mutual capacitance: Test voltage: Attenuation: Technical data Weight: bending radius, repeated: Operating temperature range min.: Operating temperature range max.: Caloric load, approx. value: Copper weight: Norms Applicable standards: Application Fixed installation, indoor 3x2x0.22 mm2 Copper, bare (AWG 24/7) PE whjbn, gnjrd, yejgn Double core Pol yester foil over stranded bundle Pol yester foil, aluminium-lined Cu braid, bare PE app. 7,0 mm ± 0,3 mm Pastel turquoise similar to RAL 6034 100 Ohm± 1 5 Ohm 96 Ohmjkm 1 GOhm x km 192 Ohmjkm max. 50 nFjkm nom. 1 kV 256 kHz < 1,5 772 kHz < 2,4 1 MHz < 2,7 4 MHz < 5,2 10 MHz < 8,4 16 MHz < 11,2 20 MHz < 11,9 app. 67 kgjkm 110mm -25°C +60°C 1,10 MJjm 35,00 kgjkm dB/1OOm dB/1OOm dB/1OOm dB/1OOm dB/1OOm dB/1OOm dB/1OOm interbus specification 2.0, IEC61158 Halogen-free ace. to 60754-2 www.hitechcontrols.com fixed installed, halogenfree H ELUKABEL ® 1- Bu s is halogen-free and designed for fixed installation in buildings in an lnterbus network. Th e cab le is used in dry areas where its halogen-free construction is a major aspect. Part no. 81557, I-BUS Dimensions and specifications may be changed without prior notice.

Upload: others

Post on 09-Aug-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BUS Cables · Fixed installation, indoor 3x2x0.22 mm2 Copper, bare (AWG 24/7) PE whjbn, gnjrd, yejgn Double core Polyester foil over stranded bundle Polyester foil, aluminium-lined

~HI-TECH ~ CONTROLS, INC.

(800) 677-8942 I (303) 680-5159 Click or Call for a Quote!

Data, Network and Bus Technology 1 HELUKABEL"' BUS-Cables

BUS Cables I-BUS

Type Cable structure Inner conductor diameter: Core insulation: Core colours: Stranding element: Shielding 1: Shielding 2: Total shielding: Outer sheath material: Cable external diameter: Outer sheath colour:

Electrical data Characteristic impedance: Conductor resistance, max.: In su lation resistance, min.: Loop resistance: Mutual capacitance: Test voltage: Attenuation:

Technical data Weight: bending radius, repeated: Operating temperature range min.: Operating temperature range max.: Caloric load, approx. value: Copper weight:

Norms Applicable standards:

Application

Fixed installation, indoor 3x2x0.22 mm2 Copper, bare (AWG 24/7) PE whjbn, gnjrd, yejgn Double core Polyester foil over stranded bundle Polyester foil, aluminium-lined Cu braid, bare PE app. 7,0 mm ± 0,3 mm Pastel turquoise similar to RAL 6034

100 Ohm± 1 5 Ohm 96 Ohmjkm 1 GOhm x km 192 Ohmjkm max. 50 nFjkm nom. 1 kV 256 kHz < 1,5 772 kHz < 2,4 1 MHz < 2,7 4 MHz < 5,2 10 MHz < 8,4 16 MHz < 11,2 20 MHz < 11,9

app. 67 kgjkm 110mm -25°C +60°C 1,10 MJjm 35,00 kgjkm

dB/1OOm dB/1OOm dB/1OOm dB/1OOm dB/1OOm dB/1OOm dB/1OOm

interbus specification 2.0, IEC61158 Halogen-free ace. to 60754-2

www.hitechcontrols.com

fixed installed, halogenfree

H ELUKABEL ® 1-Bus is halogen-free and designed for fixed installation in buildings in an lnterbus network. The cable is used in dry areas where its halogen-free construction is a major aspect.

Part no. 81557, I-BUS

Dimensions and specifications may be changed without prior notice.