bxb wmp 1200 - welcome | greentech electronics company · 2013. 2. 20. · thank you for purchasing...

8
BXB ELECTRONICS CO., LTD. 1 W W M M P P - - 1 1 2 2 0 0 6 6 Speaker Circuit Zone Selector User Manual V Ve e r r s s i i o o n n : : 1 1 . . 0 0 D D a a t t e e : : F F e e b b r r u u a a r r y y 2 2 0 0 , , 2 2 0 0 1 1 3 3

Upload: others

Post on 29-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • BXB ELECTRONICS CO., LTD.

    1

    WWMMPP--11220066 SSppeeaakkeerr CCiirrccuuiitt ZZoonnee SSeelleeccttoorr

    UUsseerr MMaannuuaall

    VVVeeerrrsssiiiooonnn::: 111...000

    DDDaaattteee::: FFFeeebbbrrruuuaaarrryyy 222000,,, 222000111333

  • BXB ELECTRONICS CO., LTD.

    2

    Contents ................................................................................................................................................ 2

    Overview ............................................................................................................................................... 3

    System Features ................................................................................................................................... 4

    Safety Instructions ............................................................................................................................... 5

    Operation and Features........................................................................................................................ 6

    Front Panel Description ....................................................................................................................... 6

    Rear Panel Description ........................................................................................................................ 7

    Connection ............................................................................................................................................ 8

    Contents

  • BXB ELECTRONICS CO., LTD.

    3

    Thank you for purchasing WMP-1206 Speaker Circuit Zone Selector from BXB Electronics Co.

    WMP-1206 is the latest speaker circuit zone selector with superb performance and elegant design

    which can be used in various occasions.

    The advanced digital control module provides 6 in 12 out single-area broadcast buttons, 1

    programmable group button and 1 all-call button to make your PA system even more powerful.

    Built-in RS-485, RS-232 and USB ports facilitate integrating with other control systems.

    High reliability is our utmost purpose when developing BXB system. Each main control unit and its

    fittings have all gone through careful assembly and strict test in our ISO 9001 approved factory. The

    excellent performance, high reliability and reasonable price make it the indispensable system for you.

    Overview

  • BXB ELECTRONICS CO., LTD.

    4

    1. 12 single-zone buttons, loads more than 300W

    2. 1 programmable group button

    3. 1 all-call button

    4. LED display on each button

    5. Group button setting can be changed anytime

    6. Zone activate by relay connection

    7. Crosstalk prevents design

    8. RS-485, RS-232 and USB ports facilitate integrating with other control systems

    9. Input control flip-flops for remote activate timer-clock

    10. Output control flip-flops for remote activate amplifier

    11. WMP-1206 can be used individually or used with digital/ analog connect. With RS-485 port, it can

    expand another WMP-1206; expand apparatuses are unlimited when using analog contacts.

    12. Up to 6 speaker circuit inputs and 12 speaker circuit outputs for random combination.

    13. Multiple units connectable for area expansion.

    【Specification】

    ◎ Power Supply: DC15V/1A (MAX)

    ◎ Output: 12 zones, 300W for each zone, maximum 3600W in total

    ◎ 12 single-zone switches, 1 group switch and 1 all-zone switch

    ◎ 1 remote all-call input terminal

    ◎ All the switches are equipped with indicators.

    ◎ W 483 x H 89 x D 270 (mm)

    System Features

  • BXB ELECTRONICS CO., LTD.

    5

    Safety Instructions

    1. Please read and observe these instructions before installing and using the apparatus.

    2. Use only accessories specified by the manufacturer. The manufacturer is not liable for damage

    caused by the use of non-specified accessories.

    3. Install the apparatus and its accessories carefully. Strike and fierce shaking may damage the

    apparatus.

    4. Make sure the power cord is fixed properly.

    5. Do not overload wall outlets and extension cords as this can result in a risk of fire or short circuit.

    6. To reduce the risk of damage from lightning strikes, it is important that all electric cables should

    be bonded to the same grounding point.

    7. Do not block any ventilation openings to prevent overheating and malfunction.

    8. Do not expose the apparatus to rain or moisture.

    Humidity may lead inside components to damage. Appropriate shelter is necessary when placing

    it outside (Best working environment: Temperature 0°C ~ 40°C , humidity below

    90%).

    9. Please do not switch on and off the apparatus rapidly.

    Rapid switch on and off the apparatus should be avoided all the time to prevent inside sensitive

    electronic circuits from being damaged by surges.

    10. Do not clean the apparatus and its accessories with chemical solvents. Use only a clean,

    dry/dampish cloth.

    11. Refer to maintenance technician when the apparatus has been damaged in any way, such as:

    A• power-supply cord or plug is damaged

    B• liquid has been spilled in

    C• has been exposed to rain or moisture

    D• has been dropped

    E• objects have fallen into the apparatus

    F• does not operate normally

    12. Note: When the printed circuit board is going through electric static treatment, correct ESD

    safety precaution and grounding should be assured.

    13. Note: Before connecting the apparatus to main AC, please select the supply voltage in

    accordance with the wall voltage in your country to prevent damage. Refer to Installation and

    Setting (Page 8) for selecting.

    14. Warning: Do not disassemble or remodel the product, as these actions may lead to electrical

    shock or damage. The guarantee on the product will become null if the product is ever

    disassembled.

  • BXB ELECTRONICS CO., LTD.

    6

    Front Panel Description

    ○1 1-12 single-zone broadcast buttons

    ○2 1-12 single-zone LED indicators

    ○3 Programmable group button

    Simply press the group button and you can broadcast to preset groups.

    Preset groups:

    Press the single zones that you want to added in the group button (LED is on), and then press

    the group button for three seconds, flashing LED means setting is saved.

    Repeat instructions above to change setting. Reprogram the memory is not essential.

    ○4 Group broadcast LED indicator

    ○5 All-zone broadcast LED indicator

    Operation and Features

  • BXB ELECTRONICS CO., LTD.

    7

    Rear Panel Description

    USB

    RS-485

    RS-232

    DC 15V/2AID

    OUTPUT

    INPUT

    100V COM

    BGM

    ○1 BGM background music amplifier (COM/100V) input terminal

    ○2 1-6 groups of speaker circuit input terminal (1 input corresponds to 2 outputs)

    ○3 RS-485 communication port for other controller expansion

    ○4 USB 2.0: USB port (connects to PC for BXB graphical control software)

    ○5 RS-232 communication port for other control systems

    2nd foot: Transmitted Data (Tx)

    3rd foot: Received Data (Rx)

    5th foot: Signal Ground (G)

    ○6 1-12 groups of speaker circuit output terminal (2 outputs correspond to1 input)

    ○7 ID: DIP switch identity code (for expanders)

    ○8 External dry contact: all zone broadcast activates when contacted.

    ○9 Dry contact: contacted when WMP-1206 is activated (to activate amplifier).

    ○10 WMP-1206 working voltage: DC12V ~ DC15V (MAX)

  • BXB ELECTRONICS CO., LTD.

    8

    Connection

    Sound amplifies to 100V high voltage through power amplifiers, and transmits to WMP1206. Last, it is

    outputted to speakers that broadcaster prefer. Dry contacts are triggered when the zone is activated,

    they would turn on power amplifiers.

    CD Player

    LEVEL

    POWER

    PL

    AC0FF

    ON

    AUTO FUSE AUTO FUSE

    DC

    Amplifier

    BXB graphical managing controller

    USB PORT

    Microphone

    STANDBY/ON

    STANDBYOPEN/CLOSE

    01INDEX

    EDIT

    01TRACK MIN

    00:00

    SEC

    DISPLAY OFFTIME

    disc..AUTO

    EDITHI-LITE

    CD-DECK SYNCHIROPROGRAM

    .COMPU

    RANDOM REPEAT

    1 2 3 4 5 6

    87 9 10 11 12

    ALL Call

    Dry Contact Output

    POWER

    WMP-1206

    AMX-1001 Mixer

    Dry Contact Input

    Ceiling-mounted or Wall Speaker

    Audio Signal

    LEVEL

    POWER

    PL

    AC0FF

    ON

    AUTO FUSE AUTO FUSE

    DC

    Amplifier

    1 2 3 4 5 6

    87 9 10 11 12

    ALL Call

    LEVEL

    POWER

    PL

    AC0FF

    ON

    AUTO FUSE AUTO FUSE

    DC

    Amplifier

    High

    1 2 3 4 5 6

    87 9 10 11 12

    ALL Call

    Up to 4 units, 48 zones

    Zone 1

    Ceiling-mounted or Wall Speaker

    Zone 2

    Other application control system

    RS-232 PORT

    Ceiling-mounted or Wall Speaker

    Zone 11

    Ceiling-mounted or Wall Speaker

    Zone 12

    Ceiling-mounted or Wall Speaker

    Zone 3

    Ceiling-mounted or Wall Speaker

    Zone 4

    Ceiling-mounted or Wall Speaker

    Zone 5

    Ceiling-mounted or Wall Speaker

    Zone 6

    OUTPUT1,2

    OUTPUT3,4

    OUTPUT5,6

    OUTPUT11,12

    WMP-1206

    WMP-1206

    RS-485PORT

    CD Player

    Microphone

    STANDBY/ON

    STANDBYOPEN/CLOSE

    01INDEX

    EDIT

    01TRACK MIN

    00:00

    SEC

    DISPLAY OFFTIME

    disc..AUTO

    EDITHI-LITE

    CD-DECK SYNCHIROPROGRAM

    .COMPU

    RANDOM REPEAT

    POWER

    AMX-1001 Mixer

    CD Player

    Microphone

    STANDBY/ON

    STANDBYOPEN/CLOSE

    01INDEX

    EDIT

    01TRACK MIN

    00:00

    SEC

    DISPLAY OFFTIME

    disc..AUTO

    EDITHI-LITE

    CD-DECK SYNCHIROPROGRAM

    .COMPU

    RANDOM REPEAT

    POWER

    AMX-1001 Mixer

    CD Player

    Microphone

    STANDBY/ON

    STANDBYOPEN/CLOSE

    01INDEX

    EDIT

    01TRACK MIN

    00:00SEC

    DISPLAY OFFTIME

    disc..AUTO

    EDITHI-LITE

    CD-DECK SYNCHIROPROGRAM

    .COMPU

    RANDOM REPEAT

    POWER

    AMX-1001 Mixer

    Audio Signal

    Audio Signal

    Audio Signal LEVEL

    POWER

    PL

    AC0FF

    ONAUTO FUSE AUTO FUSE

    DC

    Amplifier

    INPUT1

    INPUT2

    INPUT3

    INPUT6

    VoltageSignal

    100V/COM

    HighVoltageSignal

    100V/COM

    HighVoltageSignal

    100V/COM

    HighVoltageSignal

    100V/COM

    High Voltage Signal(Max 300W for each zone)

    1 2 3 4 5 6

    87 9 10 11 12

    ALL Call

    WMP-1206

    RS-485PORT

    RS-485PORT

    BXB Electronics Co., LTD. TAIWAN | Website: www.bxb.tw

    PA System / Conference System / Language Laboratory System

    TEL:+886(7)970-3838 FAX:+886(7)970-3883

    http://www.bxb.tw/