by. what’s so great about garage guy? standard features tubular heat exchanger odp motor direct...

25
by

Upload: jermaine-capener

Post on 01-Apr-2015

218 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

by

Page 2: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

WHAT’S SO GREAT ABOUT GARAGE GUY?

STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable, Locking Louvers Full Width Hanger Brackets

Page 3: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

WHAT’S SO GREAT ABOUT GARAGE GUY?

OptionsTwo Stage (60-120)Stainless Steel HX Stainless Steel Flue CollectorTotally Enclosed Motors (60-120)

Page 4: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

WHAT’S SO GREAT ABOUT GARAGE GUY?

82 – 83%

Thermal Efficiency

Page 5: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

GARAGE GUY HEATER

105 MBH 120 MBH

60 MBH 75 MBH 90 MBH

30 MBH 45 MBH

Page 6: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

Garage Guy Wholesale Advantage

TF 100

TF 90

TF 75

TF 45

TF 30

RF 90

RF 60

RF 45

RF 30

SF 45

TF 125

GG 90

GG 105

GG 125

GG 60

GG 75

GG 30

GG 45

SF 30

TF 60

RF 75

SF 60

SF 75

QVEF 75

QVEF 60

QVEF 45

QVEF 30

Page 7: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

TF100 34H x 13W x 43D 133#

TF125 34H x 13W x 43D 145#

GG105 23H x 30W x 26D 103#

GG120 23H x 30W x 26D 112#

NEW LOWER PROFILE

Page 8: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

SINGLE ORIFICE BURNER

Page 9: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

ORFICE SCHEDULE

Page 10: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

CONVERSION KITS

11CKNTPDS030-52

11CKNTPDS045-48

11CKNTPDS060-42

11CKNTPDS075-37

11CKNTPDS090-35

11CKNTPDS105-31

11CKNTPDS1201/8

CK = Conversion Kit

NTP = Natural to Propane

DS = Direct Spark

030 = Unit Size

52 = Orifice Size

IN EVERY BOX WITH

UNIT!!

Page 11: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

CONVERSION

1 HOUR

15 MINUTES

Page 12: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

SEPARATED COMBUSTION

Page 13: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

SEPARATED COMBUSTION

Field Convertible to Separated CombustionReduced Inventory RequirementsMore Installation Options with Optional Vent KitReduced Cost for Separated Combustion Applications

Page 14: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

GG120

Gasket Installation for Separated Combustion

Page 15: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

GG120

Page 16: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

GG120

Page 17: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

Competitive ProductsReznor UDAP/S

30-125 MBH Residentially Approved TCORE2 Heat Exchanger

Titanium Stabilized Aluminized 409 & 316 SS Available HX Option 82%-83% Thermal Efficiency Single Burner Combustion System Vibration/Noise isolated Fan &

Venter Motors Standard Model UDAS Separated

Combustion Multi-Try Direct Spark Ignition w/

100% Lockout

Page 18: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

Competitive ProductsModine HD / HDS

30-125 MBH Residentially Approved HD Series 30 MBH – 125 MBH Aluminized Heat Exchanger 409 & 316 SS Available HX Option 82%-83% Thermal Efficiency Single Burner Combustion System Vibration/Noise isolated Fan &

Venter Motors Standard HD Series Single & Two-Stage

Control Options Model UDAS Separated

Combustion Multi-Try Direct Spark Ignition w/

100% Lockout

Page 19: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

HOMEOWNER BROCHURE

Page 20: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

GARAGE GUY WEBSITE

Page 21: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

GARAGE GUY STUFFERS

Page 22: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

LITERATURE

Page 23: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

DISPLAY

Acrobat Document

Page 24: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,

Garage Guy Q & A

Q: Must the concentric vent kit be used when installing the unit in a separated combustion application?

A: Yes. The kit includes the inlet air adaptor as well as the concentric venting components.

Q: Can you flip the new Garage Guy unit to accommodate left hand control access?

A: Yes. We retained this popular feature.Q: What unit sizes are able to be shipped via UPS?A: GG030, GG045 and GG060 can ship safely by UPS. Handle knock-outs

have been added to these cartons for easier handling. The GG075 meets UPS dimension and weight limits but experience shows that often UPS handlers roll these units so LTL shipment is recommended.

Q. How do we set up or Qualify Premier Garage Guy Dealers?A. Sterling Distributor should provide prospective Garage Guy Dealers to

Sterling representative. Once qualified the prospective dealer will be added to the website referral area that they serve and will receive promotional Garage Guy items.

Page 25: By. WHAT’S SO GREAT ABOUT GARAGE GUY? STANDARD FEATURES Tubular Heat Exchanger ODP Motor Direct Spark Ignition OSHA Fan Guard 321SS Burner Box Adjustable,