C184-E026 GC-2025 Energy Saving Capillary Gas Chromatograph Energy Saving Capillary Gas Chromatograph

Upload: others

Post on 26-Feb-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

C184-E026

GC-2025Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph

C184_0026_GC_2025_E.indd 1C184_0026_GC_2025_E.indd 1 10.11.17 4:37:09 PM10.11.17 4:37:09 PM

Page 2: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

Energy Saving Capillary Gas Chromatograph

GC-2025

Eco-friendly

Compact - All in One

High Performance

GCsolution Ver.2

Options . Specif ications

P. 4–5

P. 6–7

P. 8–9

P. 10–11

P. 12

C184_0026_GC_2025_E.indd 2C184_0026_GC_2025_E.indd 2 10.11.17 4:37:10 PM10.11.17 4:37:10 PM

Page 3: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

Shimadzu’s new-generation GC-2025 capillary gas chromatograph minimizes environ-

mental impact by reducing power and carrier gas consumption while retaining the

performance capabilities required for capillary analysis.

The GC-2025 incorporates a digital flow controller that controls both the carrier and

detector gases and a newly designed energy-saving column oven that features small

volume and less heating loss, realizing a dramatic improvement in operability.

The compact GC-2025 is the gas chromatograph for environmentally friendly, high value

performance.

GC for EcologyE n v i r o n m e n t a l l y F r i e n d l y

This product conforms to Shimadzu'sEco-labeled designation.

* Energy savings: 30% reduction as compared to the previous model

Shimadzu’s new-generation GC-2025 capillary gas chromatograph minimizes env

mental impact by reducing power and carrier gas consumption while retaining

performance capabilities required for capillary analysis.

The GC-2025 incorporates a digital flow controller that controls both the carrier

detector gases and a newly designed energy-saving column oven that features s

volume and less heating loss, realizing a dramatic improvement in operability.

The compact GC-2025 is the gas chromatograph for environmentally friendly, high v

performance.

This product conforms toEco-labeled design

* Energy savings: 30% r compared to the previ

C184_0026_GC_2025_E.indd 3C184_0026_GC_2025_E.indd 3 10.11.17 4:37:13 PM10.11.17 4:37:13 PM

Page 4: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

Eco-friendly

4

Unique, Eco-friendly Technology for High Energy Savings A compact design and efficient insulating materials inside the oven minimize the heat capacity and heat loss, thereby reducing electricity costs and realizing more environmentally friendly operation. Furthermore, the GC-2025 is equipped with an energy-saving heater, which results in a 30% (*) reduction in electricity consumption during temperature-programming analysis as compared to the GC-2010 Plus.

Power Consumption DisplayFunction In addition to instrument status, the power consumption is displayed on the main screen. With this meter, power consumption can be checked at a glance, helping to increase awareness of energy savings and ecology in the laboratory.

(*) Power consumption varies according to site conditions, ambient temperature, etc.

200W or below201~400W401~600W601~800W801~1000W1001~1200WOver 1200W

Power meter shown on the right

The relationship betweenelectricity consumption andmeter display

□□□□□□□□□□□□□□■□□□□■■□□□□■■■

Change in electricity consumption during temperature-programminganalysis with conventional model and GC-2025

Pow

er c

onsu

mpt

ion

[kw

]

0

50

100

150

200

250

300

Conventional model GC-2025

Comparative example of the power consumptionused during 1 analytical cycle.

0

100

200

300

400

500

600

700

0 10 20 30 400

50

100

150

200

250

300

Conventional model

GC-2025

Column oven temperature

Elec

tric

ity[W

]

Col

umn

oven

tem

pera

ture

(℃)

Time[min]

Cooling30% reduction

C184_0026_GC_2025_E.indd 4C184_0026_GC_2025_E.indd 4 10.11.17 4:37:17 PM10.11.17 4:37:17 PM

Page 5: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

GC-2025Energy Saving Capillary Gas Chromatograph

5

Because helium is an expensive resource, its use as carrier gas should be minimized. The carrier gas saver function allows you to reduce the carrier gas emitted from the system by reducing the split ratio in the analysis. In a split / splitless sample injection method, this function can save valuable carrier gas and thus reduce operating costs.

Auto-stop Function / Auto-start FunctionThe auto-stop and auto-start functions help to reduce operating costs. The automatic shutdown function automatically stops the temperature control after GC analysis to save power. Furthermore, it stops the control of the detector and carrier gases after a set time. If the automatic startup function is used, gas control will be started after a set time; the temperature control will start subsequently.

Reduced Operating Costs During annual operation, when the auto start/auto stop functions of the GC-2025 are used, a reduction in power consumption of nearly 57% will be realized as compared to the existing model. In addition, CO2 emissions will be reduced by approximately 378kg.

*Annual operation is defined as 260 days. A power conversion factor of 0.378kg-CO2/kwh used.

* Power consumption may differ depending on the installation conditions, room temperature, etc.

Carrier Gas Saver Function

Analysis time: 30min Split ratio: 100Carrier gas saver function: Split ratio 10 after 1 min Column temperature 170℃ Column: Inner diameter 0.25mm, length 30m, thickness 0.25µm

Auto stop of gas control Auto start of gas control

Auto start of temperature control

Next day

End of analysis Start of analysis

Temperature and gas control continues until the next day’s analysis

Used

Not used

Comparison of consumption using the auto stop /auto start functions and not using them.

Reduce electricity andgas consumptionAuto stop of temperature control

10o’clock 11o’clock 0o’clock 1o’clock 2o’clock 3o’clock 4o’clock 5o’clock 6o’clock 7o’clock 8o’clock 9o’clock

In this case, set the split ratio to 100 in the sample injection; in other analyses, the split ratio can be reduced to 10. As a result, carrier gas consumption will be minimized.In addition, the carrier gas saver is on after the batch analysis.

Carrier gas saver function is activated until the beginning of the next batch analysis.

Example of carrier gas saver function Split ratio

100

10

0 Time

Carrier gas saved Carrier gas savedCarrier

gassaved

Carriergas

saved

start end startanalysis analysis analysis analysis

Ann

ual e

nerg

y co

nsum

ptio

n [k

Wh]

Continuous operations(our conventional model)

When using auto start/autostop functions

(GC-2025)

Approx. 57% reductionin power consumption

CO2 reduction ofabout 237kg

Hel

ium

con

sum

ptio

n [m

L]

0

500

1000

1500

2000

2500

No use When using the saver function

Reduction of He carrier gas consumption during oneanalysis using the carrier gas saver function.

Approx. 83%reduction

0

2 0 0

4 0 0

6 0 0

8 0 0

1 0 0 0

1 2 0 0

1 4 0 0

1 6 0 0

1 8 0 0

2 0 0 0

Comparative example of the annual power consumption during continuous operation using our conventional model and the GC-2025 when automatic functions are used.

C184_0026_GC_2025_E.indd 5C184_0026_GC_2025_E.indd 5 10.11.17 4:37:17 PM10.11.17 4:37:17 PM

Page 6: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

Compact All-in-One Design

6

There is increasing interest from researchers for smaller instruments that more effectively utilize laboratory space. With a compact design, the GC-2025 minimizes space requirements while maintaining the necessary features for normal capillary analysis. The column oven has been conveniently designed to accommodate commercially available columns. (A capillary column with 9cm or less coil height can be installed.)

・・ Split/splitless injection unit.・ Equipped with an advanced flow controller (AFC) that can control up to 970kPa and makes high-speed analysis using a narrow bore

column possible.・ Can decrease the amount of splitless gas using the carrier gas saving function.・ Allows high-pressure split and splitless injection.

Advanced pressure controller (APC) enables the detector gas flow rate to be set digitally.

For carrier gas, the advanced flow controller (AFC) enables the column flow rate and split conditions to be set digitally. Advanced functions, such as the carrier gas constant linear velocity mode, are easily set.

A column can be equipped for a capillary column.

The AOC-20 automatic liquid sample injection system can be attached as an option.

・ Auto ignition, auto re-ignition and automatic shutoff functions are equipped as standard.・ Equipped with a feedback function is included to shut off the

hydrogen gas supply in the event of detector flameout. ・ Wrong piping connection for hydrogen is prevented by using a

left-handed thread in the joint of the hydrogen gas supply.

SPL

AFC

APC

AOC-20Series FID

One detector

CapillarySingle column

C184_0026_GC_2025_E.indd 6C184_0026_GC_2025_E.indd 6 10.11.17 4:37:18 PM10.11.17 4:37:18 PM

Page 7: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

GC-2025Energy Saving Capillary Gas Chromatograph

7

Space-saving Design Enables Easy Installation Anywhere

・ ・

・ ・

GC-2010 Plus GC-2025 GC-2014

Size comparison with Shimadzu previous model

GC upper surface GC-2014

GC-2010 Plus

GC-2025

Width 40cm

Width 40cmWidth 51.5cm

Hei

ght

44cm

Hei

ght

42cm

Wid

th 6

0.7c

m o

f G

C-2

014

Wid

th 5

3cm

of

GC

-201

0 Pl

us

Wid

th 4

9cm

of

GC

-202

5

Hei

ght

69cm

C184_0026_GC_2025_E.indd 7C184_0026_GC_2025_E.indd 7 10.11.17 4:37:19 PM10.11.17 4:37:19 PM

Page 8: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

8

In addition to its eco-friendly features, the GC-2025 inherits the functionality of Shimadzu’s high-end capillary gas chromatograph, GC-2010 Plus, delivering superb performance for capillary analysis. GC-2025 provides high-quality analytical results and improved productivity.

High Performance

The same high-accuracy AFC as used in the GC-2010 Plus and an advanced design split/splitless injection unit realize high repeatability of retention time and peak area.

High Precision

Analysis of Grob Text Mixture (Solvent: Acetone analytes 100ppm each)

Reproducibility of peak area

34193

33079

34664

43906

29858

30919

39795

33023

33747

32882

34400

43574

29622

30689

39495

32659

33629

32727

34284

43332

29513

30605

39243

32636

33576

32712

34252

43408

29468

30531

39279

32596

33541

32769

34257

43434

29510

30579

39209

32689

33737.1

32833.9

34371.4

43530.9

29594.4

30664.5

39404.2

32720.7

266.5418

152.3486

174.3561

227.3048

157.9951

153.0667

245.2999

172.2095

0.790055

0.463999

0.507271

0.522169

0.533869

0.499166

0.622521

0.526302

n-Decane

n-Octyl Alcohol

n-Undecane

2,6-Dimethylaniline

Methyl n-Nonanoate

Methyl n-Caprate

Dicyclohexylamine

Methyl Laurate

1 2 3 4 5 Average Standarddeviation C.V.%

1

2

3

4

5

C184_0026_GC_2025_E.indd 8C184_0026_GC_2025_E.indd 8 10.11.17 4:37:21 PM10.11.17 4:37:21 PM

Page 9: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

GC-2025Energy Saving Capillary Gas Chromatograph

9

Constant carrier gas linear velocity mode

Chromatogram comparison of constant carrier gas linearvelocity mode with constant column flow mode(Pesticide analysis from a golf course)

Constant column flow mode

[Analysis Conditions] Column: DB1 30m×0.32mm i.d.df=0.25µmColumn temperature: 60℃ (1min)-7℃ /min-230℃Injector temperature: 240℃Detector temperature: 270℃Carrier gas: HeliumCarrier gas linear velocity: 40cm/sec, Column head pressure: 44.0kPaSample injection volume: 1µL (splitless analysis)

Narrow-bore capillary columns reduce analysis time and improve production capacity. With its advanced flow controller (maximum pressure: 970kPa, maximum flow rate: 1200mL/min), the GC-2025 is suitable for high-speed analyses using narrow-bore capillary columns.

High-speed analysis of coffee flavor compounds

DB-WAX0.25mm×60m, 0.25µm( He 25cm/s )

60分

Analysis time using a conventional model

Analysis time using the GC-2025

20分

Rtx-WAX0.1mm×20m, 0.1µm ( He 25cm/s )

6 12

3 5

High-Speed Scanning

For carrier gas control, configuration with the carrier gas linear velocity mode is recommended.With this mode, you can reduce the time needed to determine analytical conditions for acquiring the best chromatographic separations.

Constant Linear Velocity Mode Reduces Method Development Time

A large window display contains pertinent information and a graphical user interface makes it possible to define analytical conditions quickly.The built-in help function makes operation easy, even for new users.In addition, analysis conditions can be reset, enabling digital setup of all instrument param-eters.

Simple Operation

Analysis time using previous Shimadzu instrument

Analysis time reduced using GC-2025

C184_0026_GC_2025_E.indd 9C184_0026_GC_2025_E.indd 9 10.11.17 4:37:22 PM10.11.17 4:37:22 PM

Page 10: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

10

GCsolution workstation software improves productivity, reliability, and operability with the "Assistant Bar" and "Data Explorer" functions. Moreover, the high-level operating environment supports GLP/GMP compliance for pharmaceutical and environment applications.

Shimadzu Gas Chromatography Workstation GCsolut ion Ver.2 (Windows7)

Easy Operation for Improved Productivity

Enhanced Basic Functions

● Common operation system in LabSolutions series has been adopted, for more intuitive operation and a shorter learning curve.● The software features an enhanced manipulation function for improved operability and functionality.

● Control and data processing function enable use of up to 4 GC systems. Corresponding models: GC-2025, GC-2010 Plus, GC-2010, GC-2014, GC-17A, GC-1700, and GC-14A/B

Network Support

Supports GLP/GMP● For improved data reliabil ity, GCsolution supports GLP/GMP with its user-management, self-diagnosis, and audit trail functions● An optional function for supporting Part11 is available.

Customizing● An easier custom-designed operating environment using the OLE automation function can be constructed.

● A network environment for remote access and data analysis can be effectively implemented.● Sharing various fi les and the uniform management of data are possible using "CLASS-Agent".

OS● An Windows 7 Professional / Windows XP Professional / Windows Vista Business

● The data processing functions in Chromatopac and CLASS-GC10 have been implemented.● The identification, quantitation and data comparison functions have been enhanced.● The data station offers flexible report options and the summary report can be output.

C184_0026_GC_2025_E.indd 10C184_0026_GC_2025_E.indd 10 10.11.17 4:37:24 PM10.11.17 4:37:24 PM

Page 11: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

GC-2025Energy Saving Capillary Gas Chromatograph

11

• • The “Assistant Bar” allows navigation operation from analysis

start to post-run analysis using simple icons.

• • « Data Explorer » classifies and displays files.

Easy Operation “Assistant Bar” and“Data Explorer”

• • Analysis of many samples continuously with the Batch

Table Wizard.

• • Using the Wizard instructions, simply enter the necessary

items for easy batch table creation.

“Batch Table Wizard” MakesContinuous Analysis Easier

• • Easily construct reports.

• • Paste and edit items such as chromatograms and peak tables without any limitation.

• • Completed report formats can be saved as templates.

• • “LabSolutions” is equipped with a PDF output function as standard. Save analysis reports as

PDF files to promote paperless operation.

Editing Reports « Report creation function »

Assistant Bar

Data Explorer

■SoftwareCorresponds with Windows 7 Professional / Windows XP Professional / Windows Vista Business32Bit application (correspondent with long file name)Graphical U/I (Assistant Bar etc.)

■Controllable equipmentGC-2025, GC-2010 Plus, GC-2010, GC-2014, GC-17A, GC-1700, GC-14A/B,AOC-20i/s, TurboMatrix*, AOC-5000*.Max 4 GCs (9 detectors) can be controlled simultaneously .Max 4 detectors (GC-2010) or 2 detectors (GC except for GC-2010) can control dual injection.* Optional s/w is necessary to control Turbo matrix, AOC-5000.

■Data acquisitionMinimum sampling time 4ms, Snapshot function, Single/Batch analysis control, Batch table wizard, Additional/cutting-in analysis, Analysis time extension, Auto data file creation function, QA/QC (statistical calculation) function, Auto batch stopping function, User program starting function, Correspondent with pre-run program, Correspondent with OLE automation (batch analysis etc.)

■Data processingUndulation processing function, manipulation function, identification function (with multi relative retention time and grouping), quantitative function (least squares method, modified least squares method, internal standard method, external standard method, standard additional method, retention index calculation, manual response factor entering), weighted and linear calibration (16 levels x 10 points), Manual calibration curve creation, column performance calculation, data comparison function

■ReportingOver 10 items such as Sample information, Method, Chromatogram, Peak table, Calibration curve, Grouping result, Figures, Texts, etc. Corresponds with OLE object, Customized layouts, Preview function, Summary report.

■FilesData explorer for file controlling, All-in-one file system, File transforming function (CLASS-GC10 form, AIA ANDI form, Text form), File explorer function, Template function

■H/WGC auto stop/start functions, System check (GC self-check) function, Status log function

■GLP/GMPAudit trail function, Software validation, Security function, Part 11 function (Optional)

■Available networkPost-run application s/w (Second use license s/w, optional, GC-LAN connectable (Optional)

■OtherMaintenance guide (GC-2025, GC-2010 Plus, GC-2010, GC-2014, GC-17A/1700, GC-14A/B, AOC-20i)

Specifications of GCsolution Ver.2

C184_0026_GC_2025_E.indd 11C184_0026_GC_2025_E.indd 11 10.11.17 4:37:25 PM10.11.17 4:37:25 PM

Page 12: C184 0026 GC 2025 E - Armgate · 2014. 2. 10. · C184-E026 GC-2025 Energy Saving Capillary Gas ChromatographEnergy Saving Capillary Gas Chromatograph CC184_0026_GC_2025_E.indd 1184_0026_GC_2025_E.indd

Automatic liquid sample injection system, AOC-20 Series

■ Column ovenTemp. range : Room temperature + 10 to 400℃ (*When using liquid carbon dioxide: -50 to 400℃)

Size : W250mm x H250m x D90mm

Capacity : 5.6 liters

Temp. accuracy : +/-1% of setting value

(Calibration is possible at 0.01℃)

Temp. deviation : Within 3℃ (On 180mm dia. circumference 60 mm

from rear)

Room temp. dependency : 0.01℃/℃Programming steps : 20 steps (Cooling program is possible)

Program rate setting range : -250 to 250℃/min

Total step time : ~9999.99min

* An optional part is required when using liquid carbon dioxide.

■ Split/Splitless Injection Unit (SPL)Carrier gas is digitally controlled by the AFC (Advanced Flow Controller)

Temp. range : +5 to 400℃■ FID (Hydrogen flame ionization detector)

Detector gas is digitally controlled by the APC (Advanced Pressure Controller)

Temp. range : ~ 400℃Minimum detection limit : 2pgC/s (Dodecane)

Dynamic range : 107

■ Carrier gas flow controller(Advanced Flow Controller)Pressure setting range : 0 to 970kPa

Program plate : 7 (Pressure decreasing program is possible)

Program rate setting range : -400 to 400kPa/min

Split ratio setting range : 0 to 9999.9

Total flow rate setting range : 0 to 1200mL/min

Column averaged linear velocity can be maintained during temperature

programming.

■ Display240 x 320 dot graphics display (30 digits x 16 lines)

■ Size, Weight, Power supply (GC main unit)Size : W 400mm x H 420mm x D 490mm (excluding protrusions)

Weight : 40 kg

Power supply : 115 - 230 VAC, 1700 VA (115V type)

2600 VA (230V Type), 50/60 Hz

The compact, lightweight design enables simple installation and operation. A variety of injection modes, such as solvent flush, auto injection of internal standards, and large-volume injection, are possible. In conjunction with an AOC-20s autosampler, a maximum of 150 samples (1.5ml sample vials) can be processed.

Exhaust ductA distance of over 30 cm from the back surface of a GC-2025 to a wall is required in order to secure sufficient cooling performance. If the distance is less than 30cm, an exhaust duct is recommended. When adding the exhaust duct, a distance of 25 cm from the back surface of the GC to the wall is sufficient.

Low temperature control solenoid valve, CRG-2025When controlling sub-ambient column oven temperature, a CRG-2025 makes it possible to cool the column oven with liquid carbon dioxide. The CRG-2025 consists of a solenoid valve to control refrigerant flow, a refrigerant nozzle inside the column oven, and a connection pipe to introduce refrigerant from the container. (*) When using a CRG unit, use of the pipe included with the CRG unit is recommended. Please contact your local representative in advance if centralized piping with other tubing is planned.

Specifications

Options

Printed in Japan 3295-10011-50AIK

The contents of this brochure are subject to change without notice.

JQA-0376

SHIMADZU CORPORATION. International Marketing Division3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Phone: 81(3)3219-5641 Fax. 81(3)3219-5710URL http://www.shimadzu.com

Founded in 1875, Shimadzu Corporation, a leader in the development of advanced technologies, has a distinguished history of innovation built on the foundation of contributing to society through science and technology. We maintain a global network of sales, service, technical support and applications centers on six continents, and have established long-term relationships with a host of highly trained distributors located in over 100 countries. For information about Shimadzu, and to contact your local office, please visit our Web site at www.shimadzu.com